Unauthorized use, duplication, or modification of this document in whole
or in part without the written consent of Verint Systems Inc. is strictly
prohibited.
By providing this document, Verint Systems Inc. is not making any
representations regarding the correctness or completeness of its contents
and reserves the right to alter this document at any time without notice.
Features listed in this document are subject to change. Please contact
Verint for current product features and specifications.
All marks referenced herein with the ® or TM symbol are registered
trademarks or trademarks of Verint Systems Inc. or its subsidiaries. All
rights reserved. All other marks are trademarks of their respective
owners.
Configuring a Point-to-Multipoint Repeater ............. 7
Presenting the Application ........................................................8
Connecting Power ........................ ...........................................9
Configuring the Application .....................................................11
Configuring a Point-to-Point Repeater .................. 23
Presenting the Application ......................................................24
Connecting Power ........................ .........................................25
Configuring the Application .....................................................27
Configuring a Wireless Bridge Repeater ................ 45
Presenting the Application ......................................................46
Connecting Power ........................ .........................................47
Configuring the Application .....................................................48
Page 4
Contents
Chapter 5 Installing the Equipment ....................................... 61
ivVerint Video Intelligence Solutions
Page 5
1
Overview
The Nextiva® S4300-RP is an outdoor, wireless, digital video product that
you can use to create point-to-point, point-to-multipoint, and wireless
bridge repeater applications. It covers the 2.4 GHz and 5 GHz frequency
bands in America (United States, Canada, and Mexico) and Europe, and
the 4.9 GHz public safety band in America.
Note: The S4300-RP device must be installed by certified professionals.
Prior to deployment in the field, this wireless device requires
configuration and testing.
Verint Video Intelligence Solutions1
Page 6
1: Overview
About this Guide
This installation guide provides instructions for installing and performing
the initial configuration of the S4300-RP model. It is used as a range
extender for many pairs of S4100 devices, a wireless bridge, or multiple
S4200 transmitters.
For more information on specific configuration, compliance to standards,
external antennas, access to the web interface, and other aspects of the
product, refer to the Nextiva S4300 Series User Guide.
Installation Kit
The package contents are:
ItemDescription
RepeaterS4300-RP consisting of two devices. Each
device includes an integrated antenna.
Mounting assembly setTwo sets for installation on a wall or pole
Note: You must use only antennas certified by Verint. You must enter
the antenna gain in the device to ensure that the combined
transmission power of the device and antenna does not exceed
the maximum value established by your country’s regulations. F or
more information, refer to the Nextiva S4300 Series User Guide.
Hardware Overview
The S4300-RP electronics are enclosed in a weather-tight cast aluminum
module with an integrated wide-band antenna located in the top of the
casing. All cable entries are mounted on the un derside of the module to
maintain its weatherproof properties.
4Verint Video Intelligence Solutions
Page 9
The underside consists of:
Auxiliary connector: unused
12V DC/24V AC connector
Network (RJ-45) connector
External SMA antenna connector
LEDs
A network (RJ-45) connector
A 12V DC/24V AC power connector
An auxiliary connector (unused)
An external SMA antenna connector
Three LEDs
Nextiva S4300-RP Installation Guide
Verint Video Intelligence Solutions5
Page 10
6
Verint Video Intelligence Solutions
Page 11
2
Configuring a
Point-to-Multipoint
Repeater
A point-to-multipoint repeater is used as a range extender for wireless
links, when you need a device to retransmit the signals coming from
S4200 transmitters towards the Ethernet LAN.
Verint Video Intelligence Solutions7
Page 12
2: Configuring a Point-to-Multipoint Repeater
S4300
S4200
S4300S4300
Repeater
S4300_2 in
Cell2 (master)
S4300_3 in Cell2 (slave)
S4300_1 in
Cell1 (master)
Access point
Presenting the Application
A point-to-multipoint repeater is ma de up of three S4300 devices: two for
the repeater (S4300-RP product code) and an access point. Here is a
typical application:
8Verint Video Intelligence Solutions
Page 13
Nextiva S4300-RP Installation Guide
All devices in this setup must be in the same IP subnet.
The configuration of the point-to-multipoint repeater involves:
1. Configuring and installing the S4200 transmitters. For t he procedure,
refer to the Nextiva S4200 Series Installation Guide.
2. Assembling the power devices.
3. Configuring the two devices part of the repeater (S4300-RP) and the
S4300 access point connected to the LAN, one at a time. Shut down
a device before configuring the next one. For more information about
the access point, refer to the Nextiva S4300 Installation Guide.
It is strongly recommended to configure the S4300-RP in a lab.
Connecting Power
The S4300-RP uses 12V DC or 24V AC for power.
Note: Never power more than one device at a time during the
configuration process.
Use the supplied power cable to power the devices.
Verint Video Intelligence Solutions9
Page 14
2: Configuring a Point-to-Multipoint Repeater
To power the device:
Note: Power supplies other than the approved ones (PS2440) require
verification of operation with the S4300-RP before use.
If you are using a power supply other than the one supplied by
Verint, you need to ensure that it has a minimum capacity of 1.6A
(for 12V DC) or 25 VA (for 24V AC).
1. Plug the power cable on the main connector of the device.
2. In 12V DC, connect each power wire of the power cable to the
corresponding wire of the power supply: the red wire to the input (+)
wire and the black wire to the ground wire (-). For more information,
refer to the power supply documentation.
3. In 24V AC, connect each power wire of the supplied cable to a wire
on the power supply. Both wires are used for power.
4. Connect the electrical plug into the outlet.
10Verint Video Intelligence Solutions
Page 15
Nextiva S4300-RP Installation Guide
Configuring the Application
Device configuration requires the use of the proprietary SConfigurator
tool, a proprietary tool included on the Verint web site:
www.verint.com/manuals
(
SConfigurator.exe) to the hard disk of your computer.
Configuring each device making up the point-to-multipoint repeater
involves the following sequence of steps:
1. Setting the network parameters.
2. Setting the device name and country of operation.
3. Setting the wireless parameters.
To set the initial network parameters:
1. Ensure that the device is powered and connected to the Ethernet
network.
2. Write down the serial number of the device in a safe place.
. You need to copy its executable file
3. Start SConfigurator by double-clicking
hard disk. The SConfigurator window appears.
Verint Video Intelligence Solutions11
SConfigurator.exe on your
Page 16
2: Configuring a Point-to-Multipoint Repeater
4. In the General tab, click Program Options. The Program Options
window appears.
5. Check Detect All Units on LAN.
6. Ensure that the VSIP Port is 5510; otherwise, click Default.
7. Ensure that the Discovery IP Address is 255.255.255.255;
otherwise, click Reset to Broadcast.
12Verint Video Intelligence Solutions
Page 17
Nextiva S4300-RP Installation Guide
8. Click OK.
9. Select the Units tab, then click Discover. A device of type
“Unknown” with a 169.254.X.Y IP address appears in the list; it
corresponds to your new device.
10. Select the unknown device, then click Configure.
Verint Video Intelligence Solutions13
Page 18
2: Configuring a Point-to-Multipoint Repeater
11. In the Reconfigure unit? confirmation window, click Yes. The New
Network Configuration window appears.
12. If you have a DHCP (Dyna mic Host Con fi guration Protocol) server on
your network, check Use DHCP. Otherwise, enter the IP address,
subnet mask, and gateway of the device, as provided by your
network administrator.
13. Click OK.
The device reboots with its new network configuration.
14. In the Units tab, click Discover to update the list of devices.
The new S4300-RP device appears.
14Verint Video Intelligence Solutions
Page 19
Nextiva S4300-RP Installation Guide
15. Select the device, then click Configure.
The Unit Configuration window appears.
To set the device name and country of operation:
1. In the parameter tree of the Unit Configuration window, click Unit.
2. In the Unit Name box, assign a meaningful name to the device.
Verint Video Intelligence Solutions15
Page 20
2: Configuring a Point-to-Multipoint Repeater
3. In the Country list, select the country of operation of the device.
You must assign the proper country of operation to the device, so
that it will comply to the DFS/TPC regulations, if applicable, respect
the maximum EIRP, and use the proper set of frequency channels.
4. In the confirmation window that appears, click Yes.
To set the wireless parameters of the three S4300 devices
forming the point-to-multipoint repeater:
1. In the parameter tree of the Unit Configuration window, expand the
Network structure, then click Wireless.
16Verint Video Intelligence Solutions
Page 21
Nextiva S4300-RP Installation Guide
1. In the Mode list, select SPCF for all devices.
Verint Video Intelligence Solutions17
Page 22
2: Configuring a Point-to-Multipoint Repeater
2. In the Role list, select Master for S4300_1 and S4300_2; select
Slave for S4300_3.
3. In the Band list, select the desired frequency band:
For S4300_1, select the same frequency band as the S4200
transmitters.
For S4300_2 and S4300_3, select a frequency band; it can be
the same as in S4300_1 or a different one.
4. For S4300_1 and S4300_2 (masters), select a frequency channel in
the Channel list. The channel s must be different fo r the two devices.
You can also select Auto for the automatic selection.
5. If necessary in the 4.9 GHz band, change the bandwidth in the
Channel Bandwidth list.
6. For S4300_3 (slave), select the data rate at which the wireless cell operates in the Bit Rate list.
7. For S4300_1 and S4300_2 (masters) in a DFS context with
automatic channel selection, en ter in the Starting Order list a
sequence number to delay its startup. This number must be different
for each wireless cell (for example, 1 for S4300_1 and 2 for
S4300_2).
8. In the Antenna Gain box, check that the proper value for the
integrated antenna is displayed; the gain is 8.5 dBi in the 2.4 GHz
band and 12 dBi in th e 4.9 GHz and 5 GHz bands.
18Verint Video Intelligence Solutions
Page 23
Nextiva S4300-RP Installation Guide
9. Set the wireless passkey to the value common to all devices in the
wireless cell. For the procedure, see next.
For S4300_1, use the value given in Cell1 to the S4200
transmitters.
For S4300_2 and S4300_3, use the same value, but different
than the passkey in Cell1.
Verint Video Intelligence Solutions19
Page 24
2: Configuring a Point-to-Multipoint Repeater
To set the wireless passkey:
1. In the Wireless pane, click Set Wireless Security.
20Verint Video Intelligence Solutions
Page 25
Nextiva S4300-RP Installation Guide
2. In the Format list, select the format of the passkey: Text (ASCII)
or Hexadecimal.
3. In the Passkey box, enter the new passkey (case-sensitive).
The user-supplied passkey must be unique and have exactly
16 characters if the format is Text, or 32 digits if Hexadecimal.
4. In the Confirmation box, enter again the passkey.
5. To set the wireless passkey to its default value, click Reset.
6. On a master device, to apply the new password to all associated
devices:
a. Ensure that Apply changes to connected clients/slaves is
checked.
b. Click OK.
Note: The wireless passkey of the master will be changed only
when you click OK in the Unit Configuration window.
The Changing Wireless Passkey window appears.
c.When the procedure is finished, click Close.
7. In the Set Wireless Security window, click OK.
8. In the Unit Configuration window, click OK.
Verint Video Intelligence Solutions21
Page 26
2: Configuring a Point-to-Multipoint Repeater
9. In the Warning! window that appears, click Yes to save the new
parameters.
10. In the confirmation window that appears, click OK.
The device reboots with its new wireless configuration.
22Verint Video Intelligence Solutions
Page 27
3
Configuring a
Point-to-Point
Repeater
A point-to-point repeater is a range extender for wireless links to
retransmit the signals coming from one or many S4100 transmitters to
their corresponding receivers.
Verint Video Intelligence Solutions23
Page 28
3: Configuring a Point-to-Point Repeater
S4300
S4100
1
3
2
S4300
S4100
1
3
2
Repeater
S4300_1 in Cell1S4300_2 in Cell2
Presenting the Application
A point-to-point repeater (the S4300-R P product code) is made up of two
devices separated into two colocated cells. Here is a typical application
with three pairs of S4100 devices:
24Verint Video Intelligence Solutions
Page 29
Nextiva S4300-RP Installation Guide
The configuration of the point-to-point repeater involves:
1. Configuring and installing the S4100 pairs in repeater mode. For the
procedure, refer to the Nextiva S4100 Series User Guide.
Note: You must complete the configuration of the S4100 devices
before powering up an S4300-RP.
2. Assembling the power devices.
3. Configuring the two repeater devices one at a time.
It is strongly recommended to configure the S4300-RP in a lab.
Connecting Power
The S4300-RP uses 12V DC or 24V AC for power.
Note: Never power more than one device at a time during the
configuration process.
Use the supplied power cable to power the devices.
Verint Video Intelligence Solutions25
Page 30
3: Configuring a Point-to-Point Repeater
To power the device:
Note: Power supplies other than the approved ones (PS2440) require
verification of operation with the S4300-RP before use.
If you are using a power supply other than the one supplied by
Verint, you need to ensure that it has a minimum capacity of 1.6A
(for 12V DC) or 25 VA (for 24V AC).
1. Plug the power cable on the main connector of the device.
2. In 12V DC, connect each power wire of the power cable to the
corresponding wire of the power supply: the red wire to the input (+)
wire and the black wire to the ground wire (-). For more information,
refer to the power supply documentation.
3. In 24V AC, connect each power wire of the supplied cable to a wire
on the power supply. Both wires are used for power.
4. Connect the electrical plug into the outlet.
26Verint Video Intelligence Solutions
Page 31
Nextiva S4300-RP Installation Guide
Configuring the Application
Device configuration requires the use of the proprietary SConfigurator
tool, a proprietary tool included on the Verint web site:
www.verint.com/manuals
(
SConfigurator.exe) to the hard disk of your computer.
Configuring each device making up the S4300-RP product for a
point-to-point repeater involves the followin g sequence of steps:
1. Temporarily changing the IP address of the com p uter running
SConfigurator. The recommended temporary IP settings are:
3. Setting the device name and country of operation.
4. Setting the wireless parameters.
5. Putting back the original IP address of the computer.
To change the IP address under Windows 2000:
1. From the desktop, right-click My Network Places, then choose
Properties. The Network and Dial-up Connections window appears.
. You need to copy its executable file
Verint Video Intelligence Solutions27
Page 32
3: Configuring a Point-to-Point Repeater
2. Double-click Local Area Connection. The Local Area Connection
Status window appears.
3. Click Properties. The Local Area Connection Propertie s wi ndow
appears.
28Verint Video Intelligence Solutions
Page 33
Nextiva S4300-RP Installation Guide
4. In the component list, select Internet Prot ocol (TCP/IP), then
click Properties. The Internet Protocol (TCP/IP) Properties window
appears.
Verint Video Intelligence Solutions29
Page 34
3: Configuring a Point-to-Point Repeater
5. If Use the following IP address is selected, write down the
information displayed in the box: the IP address, subnet mask, and
default gateway.
You will need these addresses to put back your computer in its initial
state once the configuration process is completed.
6. If Obtain an IP address automatically is selected, click Use the
following IP address.
7. Enter the desired IP address, subnet mask, and default gateway (the
temporary values when you are starting the configuration procedure,
or the initial values when the work is over) .
8. Click OK to close all windows.
To change the IP address under Windows XP:
1. In the Windows Start menu, select Control Panel.
2. If the classic view is enabled, select Network Selection. In the category view, select Network and Internet Connections, then
Network Connections.
3. Double-click your active LAN or Internet connection.
30Verint Video Intelligence Solutions
Page 35
Nextiva S4300-RP Installation Guide
4. Click Properties. A Properties window appears.
Verint Video Intelligence Solutions31
Page 36
3: Configuring a Point-to-Point Repeater
5. In the General tab, select the Internet Protocol (TCP/IP) item,
then click Properties. The Internet Protocol (TCP/IP) Properties
window appears.
32Verint Video Intelligence Solutions
Page 37
Nextiva S4300-RP Installation Guide
6. If Use the following IP address is selected, write down the
information displayed in the box: the IP address, subnet mask, and
default gateway.
You will need these addresses to put back your computer in its initial
state once the configuration process is completed.
7. If Obtain an IP address automatically is selected, click Use the
following IP address.
8. Enter the desired IP address, subnet mask, and default gateway (the
temporary values when you are starting the configuration procedure,
or the initial values when the work is over) .
9. Click OK to close all windows.
To set the initial network parameters:
1. Ensure that the device is powered and connected to the Ethernet
network.
2. Write down the serial number of the device in a safe place.
3. Start SConfigurator by double-clicking
SConfigurator.exe on your
hard disk. The SConfigurator window appears.
Verint Video Intelligence Solutions33
Page 38
3: Configuring a Point-to-Point Repeater
4. In the General tab, click Program Options. The Program Options
window appears.
5. Check Detect All Units on LAN.
6. Ensure that the VSIP Port is 5510; otherwise, click Default.
7. Ensure that the Discovery IP Address is 255.255.255.255;
otherwise, click Reset to Broadcast.
34Verint Video Intelligence Solutions
Page 39
Nextiva S4300-RP Installation Guide
8. Click OK.
9. Select the Units tab, then click Discover. A device of type
“Unknown” with a 169.254.X.Y IP address appears in the list; it
corresponds to your new device.
10. Select the unknown device, then click Configure.
Verint Video Intelligence Solutions35
Page 40
3: Configuring a Point-to-Point Repeater
11. In the Reconfigure unit? confirmation window, click Yes. The New
Network Configuration window appears.
12. Do not check the Use DHCP box.
13. In the IP Address box, enter 172.16.23.51 for the S4300 on the
transmitter side and 172.16.23.52 for the S4300 on the receiver
side.
14. In the Subnet box, enter 255.255.0.0.
15. In the Gateway box, enter 172.16.23.1.
16. Click OK.
The device reboots with its new network configuration.
36Verint Video Intelligence Solutions
Page 41
Nextiva S4300-RP Installation Guide
17. In the Units tab, click Discover to update the list of devices.
The new S4300 device appears.
18. Select the device, then click Configure.
The Unit Configuration window appears.
Verint Video Intelligence Solutions37
Page 42
3: Configuring a Point-to-Point Repeater
To set the device name and country of operation:
1. In the parameter tree of the Unit Configuration window, click Unit.
2. In the Unit Name box, assign a meaningful name to the device.
38Verint Video Intelligence Solutions
Page 43
Nextiva S4300-RP Installation Guide
3. In the Country list, select the country of operation of the device.
You must assign the proper country of operation to the device, so
that it will comply to the DFS/TPC regulations, if applicable, respect
the maximum EIRP, and use the proper set of frequency channels.
4. In the confirmation window that appears, click Yes.
To set the wireless parameters of the two repeater devices:
1. In the parameter tree of the Unit Configuration window, expand the
Network structure, then click Wireless.
Verint Video Intelligence Solutions39
Page 44
3: Configuring a Point-to-Point Repeater
2. In the Mode list, select SPCF for both devices.
3. In the Role list, select Master for both devices.
40Verint Video Intelligence Solutions
Page 45
Nextiva S4300-RP Installation Guide
4. In the Band list, select a frequency band. You must select the same
value for both devices.
5. In the Channel list, select a frequency channel. The channels must
be different for the two S4300 devices. You can also select Auto for
the automatic selection.
6. If necessary in the 4.9 GHz band, change the bandwidth in the
Channel Bandwidth list.
7. In a DFS context with automatic channel selection, enter in the
Starting Order list a sequence number to delay its startup. This
value must be different for each wireless cell.
8. In the Antenna Gain box, check that the proper value for the
integrated antenna is displayed; the gain is 8.5 dBi in the 2.4 GHz
band and 12 dBi in th e 4.9 GHz and 5 GHz bands.
9. Set the wireless passkey to the value common to all devices in a cell.
For S4300_1, use the value given in Cell1; for S4300_2, use the
value given in Cell2. See page 24 for the position of each device. The
wireless passkey must be different for the two S4300 devices. For
the procedure, see next.
Verint Video Intelligence Solutions41
Page 46
3: Configuring a Point-to-Point Repeater
To set the wireless passkey:
1. In the Wireless pane, click Set Wireless Security.
42Verint Video Intelligence Solutions
Page 47
Nextiva S4300-RP Installation Guide
2. In the Format list, select the format of the passkey: Text (ASCII)
or Hexadecimal.
3. In the Passkey box, enter the new passkey (case-sensitive).
The user-supplied passkey must be unique and have exactly
16 characters if the format is Text, or 32 digits if Hexadecimal.
4. In the Confirmation box, enter again the passkey.
5. To set the wireless passkey to its default value, click Reset.
6. On a master device, to apply the new password to all associated
devices:
a. Ensure that Apply changes to connected clients/slaves is
checked.
b. Click OK.
Note: The wireless passkey of the master will be changed only
when you click OK in the Unit Configuration window.
The Changing Wireless Passkey window appears.
c.When the procedure is finished, click Close.
7. In the Set Wireless Security window, click OK.
8. In the Unit Configuration window, click OK.
Verint Video Intelligence Solutions43
Page 48
3: Configuring a Point-to-Point Repeater
9. In the Warning! window that appears, click Yes to save the new
parameters.
10. In the confirmation window that appears, click OK.
The device reboots with its new wireless configuration.
11. Change the IP address of the computer back to its original value.
44Verint Video Intelligence Solutions
Page 49
4
Configuring a
Wireless Bridge
Repeater
A wireless bridge repeater is used as a range extender to retransmit the
signals exchanged by the two devices forming a wireless bridge. A typical
context is when you cannot obtain an RF line of sight between the two
devices forming the wireless bridge.
Verint Video Intelligence Solutions45
Page 50
4: Configuring a Wireless Bridge Repeater
S4300S4300
S4300S4300
Repeater
S4300_3 in Cell2 (master, S4300-RP)
S4300_2 in Cell1 (master, S4300-BR)
S4300_4 in Cell2 (slave, S4300-RP)
S4300_1 in Cell1 (slave, S4300-BR)
Presenting the Application
A wireless bridge repeater is made up of four devices: two for the
repeater (S4300-RP product code) and two for the wireless bridge
(S4300-BR product code). These devices are organized in two wireless
cells. Here is a typical application:
46Verint Video Intelligence Solutions
Page 51
Nextiva S4300-RP Installation Guide
The configuration of the point-to-point repeater involves:
1. Assembling the power devices.
2. Configuring the two S4300 devices part of the repeater (S4300-RP)
and the two devices part of the wireless bridge (S4300-BR), one at a
time. Shut down a device before configuring the next one. For more
information about the wireless bridge, refer to the Nextiva S4300-BR Installation Guide.
It is strongly recommended to configure the S4300-RP in a lab.
Connecting Power
The S4300-RP uses 12V DC or 24V AC for power.
Note: Never power more than one device at a time during the
configuration process.
Use the supplied power cable to power the devices.
Verint Video Intelligence Solutions47
Page 52
4: Configuring a Wireless Bridge Repeater
To power the device:
Note: Power supplies other than the approved ones (PS2440) require
verification of operation with the S4300-RP before use.
If you are using a power supply other than the one supplied by
Verint, you need to ensure that it has a minimum capacity of 1.6A
(for 12V DC) or 25 VA (for 24V AC).
1. Plug the power cable on the main connector of the device.
2. In 12V DC, connect each power wire of the power cable to the
corresponding wire of the power supply: the red wire to the input (+)
wire and the black wire to the ground wire (-). For more information,
refer to the power supply documentation.
3. In 24V AC, connect each power wire of the supplied cable to a wire
on the power supply. Both wires are used for power.
4. Connect the electrical plug into the outlet.
Configuring the Application
Device configuration requires the use of the proprietary SConfigurator
tool, a proprietary tool included on the Verint web site:
www.verint.com/manuals
(
SConfigurator.exe) to the hard disk of your computer.
. You need to copy its executable file
48Verint Video Intelligence Solutions
Page 53
Nextiva S4300-RP Installation Guide
Configuring each device making up the wireless bridge repeater involves
the following sequence of steps:
1. Setting the network parameters.
2. Setting the device name and country of operation.
3. Setting the wireless parameters.
To set the initial network parameters:
1. Ensure that the device is powered and connected to the Ethernet
network.
2. Write down the serial number of the device in a safe place.
3. Start SConfigurator by double-clicking
SConfigurator.exe on your
hard disk. The SConfigurator window appears.
Verint Video Intelligence Solutions49
Page 54
4: Configuring a Wireless Bridge Repeater
4. In the General tab, click Program Options. The Program Options
window appears.
5. Check Detect All Units on LAN.
6. Ensure that the VSIP Port is 5510; otherwise, click Default.
7. Ensure that the Discovery IP Address is 255.255.255.255;
otherwise, click Reset to Broadcast.
50Verint Video Intelligence Solutions
Page 55
Nextiva S4300-RP Installation Guide
8. Click OK.
9. Select the Units tab, then click Discover. A device of type
“Unknown” with a 169.254.X.Y IP address appears in the list; it
corresponds to your new device.
10. Select the unknown device, then click Configure.
Verint Video Intelligence Solutions51
Page 56
4: Configuring a Wireless Bridge Repeater
11. In the Reconfigure unit? confirmation window, click Yes. The New
Network Configuration window appears.
12. If you have a DHCP (Dyna mic Host Con fi guration Protocol) server on
your network, check Use DHCP. Otherwise, enter the IP address,
subnet mask, and gateway of the device, as provided by your
network administrator.
13. Click OK.
The device reboots with its new network configuration.
14. In the Units tab, click Discover to update the list of devices.
The new S4300-RP device appears.
52Verint Video Intelligence Solutions
Page 57
Nextiva S4300-RP Installation Guide
15. Select the device, then click Configure.
The Unit Configuration window appears.
To set the device name and country of operation:
1. In the parameter tree of the Unit Configuration window, click Unit.
2. In the Unit Name box, assign a meaningful name to the device.
Verint Video Intelligence Solutions53
Page 58
4: Configuring a Wireless Bridge Repeater
3. In the Country list, select the country of operation of the device.
You must assign the proper country of operation to the device, so
that it will comply to the DFS/TPC regulations, if applicable, respect
the maximum EIRP, and use the proper set of frequency channels.
4. In the confirmation window that appears, click Yes.
To set the wireless parameters of the repeater and wireless
bridge:
1. In the parameter tree of the Unit Configuration window, expand the
Network structure, then click Wireless.
54Verint Video Intelligence Solutions
Page 59
Nextiva S4300-RP Installation Guide
2. In the Mode list, select SPCF for all devices.
Verint Video Intelligence Solutions55
Page 60
4: Configuring a Wireless Bridge Repeater
3. In the Role list, select Master for S4300_2 and S4300_3; select
Slave for S4300_1 and S4300_4.
4. In the Band list, select the frequency band:
S4300_1 and S4300_2 must use the same band.
S4300_3 and S4300_4 must use the same band; it can be the
same as in the other cell or a different band.
5. For S4300_2 and S4300_3 (masters), select a frequency channel in
the Channel list. The channel s must be different fo r the two devices.
You can also select Auto for the automatic selection.
6. If necessary in the 4.9 GHz band, change the bandwidth in the
Channel Bandwidth list.
7. For S4300_1 and S4300_4 (slaves ), select the data r ate at which the
wireless cell operates in the Bit Rate list. These values do not need
to be the same.
8. For S4300_2 and S4300_3 (masters) in a DFS context with
automatic channel selection, en ter in the Starting Order list a
sequence number to delay its startup. This number must be different
for each wireless cell (for example, 1 for S4300_2 and 2 for
S4300_3).
9. In the Antenna Gain box, check that the proper value for the
integrated antenna is displayed; the gain is 8.5 dBi in the 2.4 GHz
band and 12 dBi in th e 4.9 GHz and 5 GHz bands.
56Verint Video Intelligence Solutions
Page 61
Nextiva S4300-RP Installation Guide
10. Set the wireless passkey to the value common to all devices in the
wireless cell. For the procedure, see next.
For S4300_1 and S4300_2, use the same passkey.
For S4300_3 and S4300_4, use the same value, but different
than the passkey in Cell1.
Verint Video Intelligence Solutions57
Page 62
4: Configuring a Wireless Bridge Repeater
To set the wireless passkey:
1. In the Wireless pane, click Set Wireless Security.
58Verint Video Intelligence Solutions
Page 63
Nextiva S4300-RP Installation Guide
2. In the Format list, select the format of the passkey: Text (ASCII)
or Hexadecimal.
3. In the Passkey box, enter the new passkey (case-sensitive).
The user-supplied passkey must be unique and have exactly
16 characters if the format is Text, or 32 digits if Hexadecimal.
4. In the Confirmation box, enter again the passkey.
5. To set the wireless passkey to its default value, click Reset.
6. On a master device, to apply the new password to all associated
devices:
a. Ensure that Apply changes to connected clients/slaves is
checked.
b. Click OK.
Note: The wireless passkey of the master will be changed only
when you click OK in the Unit Configuration window.
The Changing Wireless Passkey window appears.
c.When the procedure is finished, click Close.
7. In the Set Wireless Security window, click OK.
8. In the Unit Configuration window, click OK.
Verint Video Intelligence Solutions59
Page 64
4: Configuring a Wireless Bridge Repeater
9. In the Warning! window that appears, click Yes to save the new
parameters.
10. In the confirmation window that appears, click OK.
The device reboots with its new wireless configuration.
60Verint Video Intelligence Solutions
Page 65
5
Installing the
Equipment
After ensuring that all devices are communicating properly in a lab, you
can install them in their final locations. You can install the S4300-RP
devices either on a wall or on a pole.
A repeater is made up of two devices. Depending on the application, they
are installed back to back or facing each other. An Ethernet cable
connects the two master devices in the application.
Verint Video Intelligence Solutions61
Page 66
5: Installing the Equipment
To install the S4300-RP:
1. Fix the mounting assembly on the device, then in stall the device in
its final location.
Warning: Always mount the device with the mating connectors
pointing downwards.
Note: Position the S4300 so that its integrated antenna has a clear
RF line of sight with the antennas of the facing device(s).
For detailed instructions, refer to the Nextiva S4X00 Mounting Assembly Installation Guide included with the mounting assembly
set.
Note: You must install the mounting assembly on the S4300-RP. It
is required to properly mount and securely ground the
wireless device.
62Verint Video Intelligence Solutions
Page 67
Nextiva S4300-RP Installation Guide
Tip: If you are installing the S4300-RP equipment in a lightning prone
environment or in a site where large AC mains power fluctuations
are a common occurrence, add external surge protection to secure
your equipment. For more information, refer to the “Surge
Protection” appendix in the Nextiva S4300 Series User Guide.
Tip: If the S4300-RP is directly exposed to the sun in an environment
likely to reach 122°F (50°C), install a sun shield. Otherwise, reduce
the maximum operating temperature by 18°F (10°C) to protect the
equipment; that is, without a sun shield, the maximum
temperature should be 104°F (40°C).
2. To properly fuse the power supplied to the wireless device, install a
fuse between the power source and the power cable. The fuse must
have the following ratings: UL Listed, 250V, 2.5A, Fast-Acting.
3. Repeat step 1 and step 2 for the second device.
4. On a point-to-point repeater:
a. Ensure that the two devices are installed back to back.
b. Power the devices using the assembled power devices.
c.Connect the supplied outdoor Ethernet cable between the two
devices.
Verint Video Intelligence Solutions63
Page 68
5: Installing the Equipment
5. On a point-to-multipoint repeater:
a. Ensure that the two devices are facing each other.
b. Power the devices using the assembled power devices.
c.Connect the supplied outdoor Ethernet cable between the two
master devices (see page 8 for the illustration).
6. On a wireless bridge repeater:
a. Ensure that the two devices are facing each other.
b. Power the devices using the assembled power devices.
c.Connect the supplied outdoor Ethernet cable between the two
master devices (see page 46 for the illustration).
7. To improve the signal level between the devices, use the antenna
alignment utility from SConfigurator.
64Verint Video Intelligence Solutions