Newport iDRN-PS-1000 Owner's Manual

iDRN-PS-1000
UNIVERSAL SWITCHING POWER SUPPLY Compact DIN-Rail 24 Volt
Operator’s Manual
NEWPORT
Electronics, Inc.
L
+
-
Counters
Frequency
Meters
PID Controllers
Clock/Timers
Printers
Process Meters
On/Off
Controllers
Recorders
Relative
Humidity
Transmitters
Thermocouples
Thermistors
Wire
Rate Meters
Timers
Totalizers
Strain Gauge
Meters
Voltmeters
Multimeters
Soldering Iron
Testers
pH pens
pH Controllers
pH Electrodes
RTDs
Thermowells
Flow Sensors
For Immediate Assistance
In the U.S.A. and Canada: 1-800-NEWPORT
®
In Mexico: (95) 800-NEWPORT
SM
Or call your local NEWPORT Office.
It is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that apply. NEWPORT is constantly pursuing certification of its products to the European New Approach Directives. NEWPORT will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but NEWPORT Electronics, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
Internet e-mail
info@newportUS.com
Additional products from
NEWPORTnet
SM
On-Line Service
http://www.newportUS.com
NEWPORT
Electronics, Inc.
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.
1. General Information and Features 2
2. Safety Considerations 3
3. Installation and Removal 4
3.1 Installation Clearance 5
3.2 Mounting on DIN Rail 6
3.3 Removal of Unit 7
4. Input and Output Connections 8
4.1 Block Diagram 8
4.2 Wiring for 115 Vac - Single Phase 9
4.3 Wiring for 230 Vac - Two Phase 10
5. Specifications 11 Input Power 11 Output Power 11 General 12 Wire Connections 12
6. Dimensions 13
7. Temperature Derating Graph 14
C
ONTENTS
1
The compact iDRN power supplies are designed to supply well-regulated 24 volt DC power to sensors, signal conditioners, data acquisition systems and high level logic equipment.
Significant iDRN features include:
Tested isolation, primary to output
Recessed live parts and connector screws
35mm DIN rail mounting
Wide input voltage tolerances
Protective varistor input shunt
Input AC spike rejection with LC filters
LED power-on lamp
Over-temperature protection
Short circuit protection
Low-ripple, well-regulated design
Features
G
ENERALINFORMATION ANDFEATURES
1
2
S
AFETY
C
ONSIDERATIONS
2
3
This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility).
Unpacking & Inspection
Unpack the instrument and inspect for obvious shipping damage. Do not attempt to operate the unit if damage is found.
This instrument is a DIN rail mount device. Installation of this instrument should be done by Qualified personnel. In order to ensure safe operation, the following instructions should be followed.
This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the building installation as a disconnecting device. It shall be marked to indicate this function, and it shall be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker shall not interrupt the Protective Conductor (Earth wire), and it shall meet the relevant requirements of IEC 947–1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be incorporated in the mains supply cord.
Furthermore, to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment, an overcurrent protection device shall be installed.
The Protective Conductor must be connected for safety reasons. Check that the power cable has the proper Earth wire, and it is properly connected. It is not safe to operate this unit without the Protective Conductor Terminal connected.
Do not exceed voltage rating on the label located on the top of the instrument housing.
Always disconnect power before changing signal and power connections.
Do not use this instrument on a work bench without its case for safety reasons.
Do not operate this instrument in flammable or explosive atmospheres.
Do not expose this instrument to rain or moisture.
Unit mounting should allow for adequate ventilation to ensure instrument does not exceed operating temperature rating.
Use electrical wires with adequate size to handle mechanical strain and power requirements. Install without exposing bare wire outside the connector to minimize electrical shock hazards.
EMC Considerations
Whenever EMC is an issue, always use shielded cables.
Never run signal and power wires in the same conduit.
Use signal wire connections with twisted-pair cables.
Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.
If a rail assembly is to be transported, then disconnection, dismounting and separate packing of the power supply is recommended.
For units that must be shipped installed on the rail, additional bracing to resist transportation shocks is recommended.
Do not attempt to install or connect to the power supply when the mains are energized.
Warning!
I
NSTALLATION AND
R
EMOVAL
3
4