Newport IDP Quick Start Manual

IDP
Process Meter
12172ML-01 Rev. E MQS1866/N/0202
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.
It is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that apply. NEWPORTis constantly pursuing certification of its products to the European New Approach Directives. NEWPORTwill add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but NEWPORT Electronics, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
TRADEMARK NOTICE:
,, ,
newportUS.com
,,
, and are trademarks of NEWPORT Electronics, Inc.
TM
®
NEWPORT
®
NEWPORT
®
NEWPORT Electronics, Inc. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. In addition to NEWPORT’s standard warranty period, NEWPORT Electronics will extend the warranty period for one (1) additional year if the warranty card enclosed with each instrument is returned to NEWPORT.
If the unit should malfunction, it must be returned to the factory for evaluation. NEWPORT’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by NEWPORT, if the unit is found to be defective it will be repaired or replaced at no charge. NEWPORT’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of NEWPORT’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
NEWPORT is pleased to of fer suggestions on the use of its various products. However, NEWPORT neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by NEWPORT, either verbal or written. NEWPORT warrants only that the parts manufactured by it will be as specified and free of defects. NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of NEWPORT with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall NEWPORT be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by NEWPORT is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, or used on humans, or misused in any way, NEWPORT assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally purchaser will indemnify NEWPORT and hold NEWPORT harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Direct all warranty and repair requests/inquiries to the NEWPORT Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO NEWPORT, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM NEWPORT’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting NEWPORT:
1. P.O. number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-W
ARRANTY REPAIRS, consult NEWPORT for current repair charges. Have the following information available BEFORE contacting NEWPORT:
1. P.O. number to cover the COSTof the
repair,
2. Model and serial number of product,
and
3. Repair instructions and/or specific
problems relative to the product.
NEWPORT’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
NEWPORT is a registered trademark of NEWPORT Electronics, Inc.
© Copyright 2002 NEWPORT Electronics, Inc. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of NEWPORT Electronics, Inc.
PATENT NOTICE:The “Meter Case Bezel Design” is a trademark of NEWPORT Electronics, Inc., registered in the U.S. This product is covered by one or more of the following patents: U.S. Pat. No. Des. 336,895, 5,274,577/ Canada 2052599, 2052600/ Italy 1249456, 1250938/ France Brevet No. 91 12756/ Spain 2039150, 2048066/ UK Patent No. GB2 249 837, GB2 248 954/ Germany DE 41 34398 C2. OTHER INTERNATIONALPATENTS PENDING.
Return Requests/Inquiries
Warranty/Disclaimer
56
Configuration Mode
The following table lists display prompts that appear when the meter is in the configuration mode.
MENU
/TARE
/MAX
InP 0-10
4-20 20-4 0-5 1-5
dEc.P FFF.F
FFFF. FFFF F.FFF FF.FF
ScAL int rd1*
LivE XXXX
rd 2* *XXXX
* Shows only if you press the
/MAX button.
Tare
The following buttons enable tare functions in the run mode:
T-RST
Clears tare value
/TARE
Tares display value to zero.
Reference Information
Meter Modes
Run Mode - The meter is in the run mode when the display is actively showing a process.
Configuration Mode - The meter is in the configuration mode when you press the MENU button to enable meter configurations.
Jumpers
The following table gives you information about jumpers. Refer to the illustration below for exact jumper location. Refer to the Operator's Manual for additional jumper information.
S1 - S3 Jumpers
Jumper Description
S1 Installed: 10 V excitation
Removed: 24 V excitation
S2 Installed: Front-panel buttons locked
out Removed: All buttons operable
S3 Installed: PEAK shows when
/MAX button is pushed. PrsT (Peak Reset) is active when RESET is pushed. Press
/MAX to show PEAK value.*
Removed: VALLEY shows when
/MAX button is pushed. VrST (Valley Reset) is active when RESET is pushed. Press
/MAX to
show VALLEY value.*
*Shows in run mode only
S3
S2
S1
For immediate technical or application assistance please call:
Newport Electronics, Inc.
2229 South Yale Street • Santa Ana, CA • 92704 • U.S.A.
TEL: (714) 540-4914 • FAX: (714) 546-3022
Toll Free: 1-800-639-7678 • http://www.newportUS.com • e-mail:info@newportUS.com
ISO 9001 Certified
Newport Technologies, Inc.
976 Bergar • Laval (Quebec) • H7L 5A1 • Canada
TEL: (514) 335-3183 • FAX: (514) 856-6886
Toll Free: 1-800-639-7678 • http://www.newport.ca • e-mail:sales@newport.ca
Newport Electronics, Ltd.
One Omega Drive • River Bend Technology Centre
Northbank, Irlam • Manchester M44 5BD • United Kingdom
Tel: +44 161 777 6611 • FAX: +44 161 777 6622
Toll Free: 0800 488 488 • http://www.newportuk.co.uk • e-mail:sales@newportuk.co.uk
Newport Electronics B.V.
Postbus 8034 • 1180 LA Amstelveen • The Netherlands
TEL: +31 20 3472121 • FAX: +31 20 6434643
Toll Free: 0800 0993344 • http://www.newport.nl • e-mail: sales@newport.nl
Newport Electronics spol s.r.o.
Rudé armády 1868, 733 01 Karviná 8 • Czech Republic
TEL: +420 69 6311899 • FAX: +420 69 6311114
Toll Free: 0800-1-66342 • http://www.newport.cz • e-mail: sales@newport.cz
Newport Electronics GmbH
Daimlerstrasse 26 • D-75392 Deckenpfronn • Germany
TEL: 49 7056 9398-0 • FAX: 49 7056 9398-29
Toll Free: 0800 / 6397678 • http://www.newport.de • e-mail: sales@newport.de
Newport Electronique S.A.R.L.
9, rue Denis Papin • 78190 Trappes • France
TEL: +33 130 621 400 • FAX: +33 130 699 120
Toll Free: 0800-4-06342 • http://www.newport.fr • e-mail: sales@newport.fr
Mexico and Latin America
TEL: 001-800-826-6342 • FAX: 001 (203) 359-7807
En Español: 001 (203) 359-7803
7. Press 䊱/MAX. The display momentarily flashes “rd 1”, then shows the low calibrated value.
8. a. If you selected “int,”enter the desired display
corresponding to low input.
(0Vdc, 1Vdc, 4mA)
b. If you selected “LivE”, apply low load to
sensor and enter desired display.
Press䊱/MAX and /TARE to enter desired display.
9. Press MENU. The display momentarily flashes “rd 2”, then shows the high calibrated value.
10. a. If you selected “int”, enter the desired display
corresponding to high input. (10Vdc, 5Vdc, 20mA)
b. If you selected “LivE”, apply full scale or 3/4
full scale load to sensor and enter desired display.
Press䊱/MAX and /TARE to enter the desired display.
11. Press MENU to store new scale factor and return to the run mode.
12. If the display is not zero, with no load on your sensor, press /TARE. Scaling is now complete.
T-RST
/MAX /TARE
MENU
RESET
T-RST
/MAX /TARE
MENU
RESET
.
T-RST
/MAX /TARE
MENU
RESET
T-RST
/MAX /TARE
MENU
RESET
T-RST
/MAX /TARE
MENU
RESET
T-RST
/MAX /TARE
MENU
RESET
Connect the Sensor Input
Depending upon sensor input type, connect your sensors according to one of the following figures. If your sensor type is not shown, refer to Section 3 of the Operator’s Manual.
4 -20 mA Input with External Excitation
3-Wire dc Voltage Input with Internal Excitation
4-20 mA Transmitter with Internal Excitation
Apply Power
Plug in the meter. There is no power switch, so the meter will be active as soon as you apply power. The meter shows the following:
* Represents the revision code. Write this number down. You will need this number if you call Customer Service for assistance.
J4
1
2
3
J3
2
3
Jumper
User
Provided
2
3
1
2
3
J3
J4
EXC
SIG
COM
J4
1
2
3
START HERE
2
34
Using This Quick Start Manua
l
Use this Quick Start manual with your meter to power up, configure and scale your meter. For detailed instructions, refer to the appropriate section in the Operator’s Manual.
Wiring
1. Locate the J1 connector.
2.
Insert the correct wire in each terminal as shown in the following figure and tighten the lockdown screws.
3. Tug gently on the wires to verify the connections.
Main Power Connections - ac
Mount the Meter
1. Cut a hole in your panel, as shown in the figure below.
2. Insert the meter into the hole. Be sure the front bezel is flush to the panel.
1.772" + .024/–.000
(45.01mm + 0.61/–0.00)
3.622" + .032/–.000
(92.00mm + 0.81/–0.00)
PANEL
Line Neutral
AC Power
123
FUSE
Earth Ground
J1
Configuring and Scaling Your Meter
1. Press MENU. The meter momentarily shows “InP”, then shows last saved input range.
2. Configure the input range by pressing /TARE to select from the following: 4-20mA, 20-4mA, 0-5V, 1-5V and 0-10V.
3. Press MENU to store range. The meter momentarily shows “Stor”,“dEc.P”, and then shows the last saved decimal point location.
4. Configure the decimal point location by pressing /TARE to select from the following: FFF.F, FFFF., FFFF, F.FFF and FF.FF.
5. Press MENU to store decimal point. The meter
momentarily shows “Stor”, “ScAL”, and then shows the last saved scaling method.
6. Press /TARE to select “int” or “LivE” scaling. “int” is internal scaling, or scaling without known loads. “LivE” is applying known loads to a sensor.
...
.
*
T-RST
/MAX
/TARE
MENU
RESET
T-RST
/MAX
/TARE
MENU
RESET
T-RST
/MAX /TARE
MENU
RESET
T-RST
/MAX
/TARE
MENU
RESET
.
T-RST
/MAX
/TARE
MENU
RESET
.
T-RST
/MAX /TARE
MENU
RESET
T-RST
/MAX /TARE
MENU
RESET
T-RST
/MAX /TARE
MENU
RESET
Warning: Do not connect AC power to your device until you have completed all input and output connections. This device must only be installed by a specially trained electrician with corresponding qualifications. Failure to follow all instructions and warnings may result in injury!
Loading...