Newport DL225, DL, DL125, DL325 User Manual

G
U
A
R
A
N
T
E
D
S
P
E
C
I
F
I
C
A
T
I
O
N
S
RoHS
Compliant
DL Stage Series
High-Performance
Delay Line Stages
USERS MANUAL
DL Stage Series High-Performance Delay Line Stages
Newport Corporation warrants this product to be free from defects in material and workmanship for a period of 1 year from the date of shipment. If found to be defective during the warranty period, the product will either be repaired or replaced at Newport’s discretion.
To exercise this warranty, write or call your local Newport representative, or contact Newport headquarters in Irvine, California. You will be given prompt assistance and return instructions. Send the instrument, transportation prepaid, to the indicated service facility. Repairs will be made and the instrument returned, transportation prepaid. Repaired products are warranted for the balance of the original warranty period, or at least 90 days.
Limitation of Warranty
This warranty does not apply to defects resulting from modification or misuse of any product or part.
This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability or fitness for a particular use. Newport Corporation shall not be liable for any indirect, special, or consequential damages.
by Newport Corporation, Irvine, CA. All rights reserved.
Original instructions.
No part of this document may be reproduced or copied without the prior written approval of Newport Corporation. This document is provided for information o nl y, and pro du ct specifications are subject to change without notice. Any change will be reflected in future publishings.
CAUTION
Warranty does not apply to damages resulting from:
• Incorrect usage:
– Load on the stage greater than maximum specified load.
– Carriage speed higher than specified speed.
–Improper grounding.
¬ Connectors must be properly secured.
¬ When the load on the stage represents an electrical risk, it must
be connected to ground.
– Excessive or improper cantilever loads.
• Modification of the stage or any part thereof.
CAUTION
Please return equipment in the original (or equivalent) packing.
You will be responsible for damage incurred from inadequate packaging if the original packaging is not used.

Warranty

EDH0391En1031 — 03/18 ii
© 2018
DL Stage Series High-Performance Delay Line Stages
Table of Contents
Warranty .................................................................................................................ii
EC Declaration of Conformity...............................................................................v
Definitions and Symbols.......................................................................................vi
Warnings ...............................................................................................................vii
Cautions .................................................................................................................ix
1.0 — Introduction.................................................................................1
1.1 Unpacking Instruction ..............................................................................1
2.0 — Description ...................................................................................2
2.1 Design Details ............................................................................................2
3.0 — Characteristics............................................................................3
3.1 Definitions ..................................................................................................3
3.2 Mechanical Specifications .......................................................................4
3.3 Stage Initialization.....................................................................................4
3.4 Static Load Characteristics and Stiffness ..............................................4
3.5 Dynamic Characteristics ..........................................................................5
Description of Parameters .......................................................................5
Stages Adjustement Proposal in Function of the Load .......................5
Payload Adjustment Influence on Displacement ..................................6
DL Stage Acceleration...............................................................................6
3.6 Stage Weights ............................................................................................7
4.0 — Motor & Feedback ....................................................................7
4.1 Brushless Motor Characteristics ............................................................7
4.2 Feedback Signal Position .........................................................................7
4.3 Pinouts........................................................................................................8
Motor Connector (SUB-D25M).................................................................8
Encoder Connector (HD26M) ..................................................................8
5.0 — Connection to Newport Controllers ................................9
5.1 Warnings on Controllers ..........................................................................9
5.2 Connection ...............................................................................................10
Newport cables .......................................................................................10
6.0 — Connection to Non-Newport Electronics ....................11
6.1 Connections .............................................................................................11
7.0 — Dimensions.................................................................................12
iii EDH0391En1031 — 03/18
DL Stage Series High-Performance Delay Line Stages
8.0 — Optical Kits.................................................................................13
8.1 DL-BKIT19 Kit...........................................................................................13
8.2 DL-BKIT1U Kits ........................................................................................14
8.3 DL-BKIT2U Kits ........................................................................................14
8.4 DL-BKIT4U Kits ........................................................................................15
9.0 — Maintenance ..............................................................................16
9.1 Maintenance ............................................................................................16
9.2 Repair .......................................................................................................16
9.3 Calibration ...............................................................................................16
Service Form .........................................................................................................17
EDH0391En1031 — 03/18 iv
DL Stage Series High-Performance Delay Line Stages
Delay Line Series
EU Declaration of Conformity
following Annex II-1A of Directive 2006/42/EC on machinery
The manufacturer:
MICRO-CONTROLE Spectra-Physics, 9, rue du bois sauvage F-91055 Evry FRANCE
Hereby declares that the machinery:
y Description: " DL " y Function: High-Performance Delay Line Stages with Single-Axis Motion
Controller/Driver. y Models: DL125/225/325.
– the technical file of which was compiled by:
Mr Hervé LE COINTE, Directeur Qualité, MICRO-CONTROLE Spectra-Physics, Zone Industrielle - B.P.29 F-45340 Beaune La Rolande France
– complies with all the relevant provisions of the Directive 2006/42/EC on machinery. – complies with all the relevant provisions of the Directive 2014/30/EU relating to electro­magnetic compatibility. – complies with all the relevant provisions of the Directive 2011/65/EU relating to RoHS2.
– was designed and built in accordance with the following harmonised standards:
y NF EN 61326-1:2013 « Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements » y NF EN 55011:2010/A1:2011 Class A
– was designed and built in accordance with the following other standards:
y NF EN 61000-4-2 y NF EN 61000-4-3 y NF EN 61000-4-4 y NF EN 61000-4-5
ORIGINAL DECLARATION
Done in Beaune La Rolande on 16 May 2017 Hervé LE COINTE Quality Director
DC1-EN rev:A
y NF EN 61000-4-6 y NF EN 61000-4-8 y NF EN 61000-4-8 y NF EN 61000-4-11

EC Declaration of Conformity

v EDH0391En1031 — 03/18
DL Stage Series High-Performance Delay Line Stages
The following terms and symbols are used in this documentation and also appear on the product where safety-related issues occur.
General Warning or Caution
The exclamation symbol may appear in warning and caution tables in this document. This symbol designates an area where personal injury or damage to the equipment is possible.
The following are definitions of the Warnings, Cautions and Notes that may be used in this manual to call attention to important information regarding personal safety, safety and preservation of the equipment, or important tips.
WA RN IN G
Warning indicates a potentially dangerous situation which can result in bodily harm or death.
CAUTION
Caution indicates a potentially hazardous situation which can result in damage to product or equipment.
NOTE
Note indicates additional information that must be considered by the user or operator.
European Union CE Mark
The presence of the CE Mark on Newport Corporation equipment means that it has been designed, tested and certified as complying with all applicable European Union (CE) regulations and recommendations.
Warnings and Cautions
ATTENTIO N
This stage is a Class A device. In a residential environment, this device can cause electromagnetic interference. In this case, suitable measures must be taken by the user.

Definitions and Symbols

EDH0391En1031 — 03/18 vi
DL Stage Series High-Performance Delay Line Stages
W
ARNING
The motion of objects of all types carries potential risks for operators. Ensure the protection of operators by prohibiting access to the dangerous area and by informing the personnel of the potential risks involved.
WA RN IN G
The magnetic channel included in this device has the potential to disrupt pacemakers. Consequently, it is recommended that individuals maintain a distance of 1 meter or more from the stage as a precautionary measure.
WA RN IN G
Do not use this stage when its motor is emitting smoke or is unusually hot to the touch or is emitting any unusual odor or noise or is in any other abnormal state.
Stop using the stage immediately, switch off the motor power and then disconnect the electronics power supply.
After checking that smoke is no longer being emitted contact your Newport service facility and request repairs. Never attempt to repair the stage yourself as this can be dangerous.
WA RN IN G
Make sure that this stage is not exposed to moisture and that liquid does not get into the stage.
Nevertheless, if any liquid has entered the stage, switch off the motor power and then disconnect the electronics from power supply.
Contact your Newport service facility and request repairs.
WA RN IN G
Do not insert or drop objects into this stage, this may cause an electric shock, or lock the drive.
Do not use this stage if any foreign objects have entered the stage. Switch off the motor power and then disconnect the electronics power supply.
Contact your Newport service facility for repairs.
WA RN IN G
Do not place this stage in unstable locations such as on a wobbly table or sloping surface, where it may fall or tip over and cause injury.
If this stage has been dropped or the case has been damaged, switch off the motor power and then disconnect the electronics power supply.
Contact your Newport service facility and request repairs.

Warnings

vii EDH0391En1031 — 03/18
DL Stage Series High-Performance Delay Line Stages
WA RN IN G
Do not attempt to modify this stage; this may cause an electric shock or downgrade its performance.
W
ARNING
Do not exceed the usable depth indicated on the mounting holes (see section “Dimensions”). Longer screws can damage the mechanics or cause a short-circuit.
WARNING
Do not exceed speed and load limitations as specified in this manual.
EDH0391En1031 — 03/18 viii
DL Stage Series High-Performance Delay Line Stages
C
AUTION
Do not place this stage in a hostile environment such as X-Rays, hard UV,… or in any vacuum environment.
CAUTION
Do not place this stage in a location affected by dust, oil fumes, steam or high humidity. This may cause an electric shock.
CAUTION
Do not leave this stage in places subject to extremely high temperatures or low temperatures. This may cause an electric shock.
• Operating temperature: +10 to +35 °C
• Storage/Operating altitude: 1000 m
• Storage/Operating humidity: 85%
• Storage temperature: -10 to +40 °C (in its original packaging)
CAUTION
Do not move this stage if its motor power is on.
Make sure that the cable to the electronics is disconnected before moving the stage. Failure to do so may damage the cable and cause an electrical shock.
CAUTION
Be careful that the stage is not bumped when it is being carried. This may cause it to malfunction.
CAUTION
When handling this stage, always unplug the equipment from the power source for safety.
CAUTION
When the carriage is in its end-of-run position, it is strongly recommended not to go beyond this point as this may damage the stage mechanism.
CAUTION

Cautions

ix EDH0391En1031 — 03/18
Contact your Newport service facility to request cleaning and specification measurement every year.
Loading...