MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A
FREESTANDING FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND.
VENT-FREE
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
− Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in-
structions.
• If you cannot reach your gas supplier, call the fire department.
− Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to section “
Producing Adequate Ventilation” page 32.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Manufacturer: NEW BUCK CORPORATION
P.O. Box 69
8000 Highway 226 South
Spruce Pine, NC 28777
This appliance is intended for supplemental
heating.
Revised December 2006
Page 2
Page 3
TABLE OF CONTENTS 329
SECTION I: Safety Information ........................................................................................ 1
IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY
BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THE APPLIANCE.
IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM
BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING.
Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or
nausea. If you have these signs, the heater may not be working properly. Get fresh air at once!
Have heater serviced.
Some people-pregnant women, persons with heart or lung disease, anemia, those under the
influence of alcohol, and those at high altitudes-are more affected by carbon monoxide than
others.
CAUTION: Strong drafts, such as a ceiling fan placed directly in front of the heater
(pulling from either direction) may create sooting. Sooting will discolor
walls.
1. The installation must conform with local codes ,or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA54.
2. This appliance may be installed in an After-Market* Manufactured (Mobile) Home,
where not prohibited by state or local codes.
* (After-Market: Completion of sale, not for purpose of resale from the manufacturer.)
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
NOTE: See Section VII, “Producing Adequate Ventilation” page 32.
IMPORTANT: VENT-FREE HEATERS ADD MOISTURE TO THE AIR. ALTHOUGH THIS
IS BENEFICIAL, INSTALLING HEATER IN ROOMS WITHOUT ADEQUATE
VENTILATION MAY CAUSE MILDEW TO FORM FROM TOO MUCH MOISTURE.
3. Never install this heater:
♦ in a recreational vehicle, bathroom, bedroom, or any other sleeping quarters
♦ where curtains, furniture, clothing, or other flammable objects are less than 42" from the
front of the heater
♦ in high traffic areas or in windy areas
4. Two models are available. One specific model for propane (LP), and one for natural gas.
Use the correct type gas for your home. Do not convert from one gas type to another.
“WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.”
Page 6
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure.
Page 2
6. What To Do IF You Smell Gas:
Shut off gas supply.
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
7. When operated for the first time, the logs may emit a “paper burning” smell. This smell will
gradually diminish and will be totally eliminated after the first few hours of operation. Run the gas
logs with the flue damper open during this time. Do not use blower at this time.
8. “This heater shall not be installed in a confined space or unusually tight construction unless
provisions are provided for adequate combustion and ventilation air.” See “Producing
Adequate Ventilation”, page 32.
9. Surface of gas logs becomes very hot when operating. Keep children and adults away from hot
surface. Gas logs will remain hot for sometime after shutdown. Allow surface to cool before
touching.
10. Do not place clothing or other flammable material on or near the appliance.
11. If equipped, fresh air damper must be closed.
12. Keep appliance area clean and free from combustible materials, gasoline, and other flammable flammable vapors and liquids. .
13. If burner shuts off, do not relight until you provide fresh outside air. If burner continues to shut off,
have unit serviced.
14. Do not use this heater if any part has been under water. Immediately call qualified service
technician to inspect the room heater and to replace any part of the control system and any
gas control which has been under water.
15. Turn off the heater and let cool before servicing.
16. These logs are made of bonded fiber. When removing logs and base, do not damage the bonded
material. If the material is damaged extensively, loose fiber dust could be emitted into the air.
17. Any safety screen or guard removed for servicing an appliance must be replaced prior to
operating the heater.
18. This appliance is intended for supplemental heating.
19.
“WARNING: Any change to this heater or its controls can be dangerous.”
20. Installation and repairs should be performed by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
It is imperative that control compartments, burners and circulating air passageways of the
appliance be kept clean.
Page 7
Page 3
21. All heater screens must be kept closed when operating the gas logs.
22. . ”WARNING: Failure to keep the primary air opening (s) of the burner (s) clean may result
in sooting and property damage.”
23. Do not use this heater for burning trash or cooking. Never place matches, paper, garbage, or any
other material on top of logs or into the flames.
24. Do not install or operate this heater in areas where impurities in the air exist (such as tobacco
smoke or heavy cooking grease). Particles from impurities may discolor walls.
25. Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies.
26. Children and adults should be alerted to the hazards of high surface temperature and should
stay away to avoid burns or clothing ignition.
27. Young children should be carefully supervised when they are in the same room with the
appliance.
28. An unvented room heater having an input rating of more than 10,000 Btu per hour shall not
be installed in a bedroom or bathroom.
29. The appliance and its appliance main gas valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressure in excess of 1/2 psi
(3.5 kPa).
30. The appliance must be isolated from the gas supply piping system by closing its equipment
shut-off valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
31. “WARNING: Do not allow fans to blow directly into fireplace. Avoid any drafts that alter
burner flame patterns.”
32. “WARNING: Do not use a blower insert, heat exchanger insert or other accessory not
approved for use with this heater.”
33. Adequate clearances around air openings. Nothing may be placed over any of the air openings
on this appliance, or can any of the air openings be modified in anyway.
34. A fireplace screen must be in place when the appliance is operating and, unless other
provisions for combustion air are provided, the screen shall have an opening (s) for introduction
of combustion air.
35. WARNING: Any glass doors shall be fully opened when the appliance is in operation.
Page 8
SECTION II
Page 4
FIREPLACE PREPARATION
The fireplace needs to be prepared before installing the heater.
A. Turn off the gas supply to the fireplace.
WARNING: BEFORE INSTALLING IN A SOLID-FUEL BURNING
FIREPLACE, THE CHIMNEY FLUE AND FIREBOX MUST BE
CLEANED OF SOOT, CREOSOTE, ASHES, AND LOOSE PAINT BY A
QUALIFIED CHIMNEY CLEANER.
“WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY
INTO THE FIREPLACE. AVOID DRAFTS THAT ALTER BURNER
FLAME PATTERNS.”
“WARNING: DO NOT USE A BLOWER INSERT, HEAT
EXCHANGER INSERT OR OTHER ACCESSORIES NOT APPROVED
FOR USE WITH THIS HEATER.”
WARNING: ANY OUTSIDE AIR DUCTS AND/OR ASH DUMPS IN
THE FIREPLACE SHALL BE PERMANENTLY CLOSED AT TIME OF
APPLIANCE INSTALLATION.
B. Read the following sections before installing your unit; Section III, page 24
Installation In A Solid-Fuel Burning Fireplace and Section VIII, page 32
Producing Adequate Ventilation.
WARNING: CUTTING ANY SHEET-METAL PARTS OF THE
SOLID –FUEL BURNING FIREPLACE OR LISTED VENTLESS
FIREBOX ENCLOSURE IN WHICH THE UNVENTED FIREPLACE
INSERT IS TO BE INSTALLED IS PROHIBITED.
NOTE: ”IF THE FACTORY BUILT FIREPLACE HAS NO GAS
ACCESS HOLE(S) PROVIDED, AN ACCESS HOLE OF 1.5 inch
(37.5mm) DIAMETER OR LESS MAY BE DRILLED THROUGH THE
LOWER SIDES OR BOTTOM OF THE FIREBOX IN A PROPER
WORKMANLIKE MANNER. THIS ACCESS HOLE MUST BE
PLUGGED WITH NON-COMBUSTIBLE INSULATION AFTER THE
GAS SUPPLY LINE HAS BEEN INSTALLED.”
REFRACTORY, GLASS DOORS , SCREEN RAILS, SCREEN MESH
AND SOLID-FUEL LOG GRATES (IF APPLICABLE) CAN BE
REMOVED FROM THE FIREPLACE BEFORE INSTALLING THE
UNVENTED FIREPLACE INSERT.
Page 9
INSTALLATION AND CLEARANCES
Page 5
To ensure a safe installation into a masonry or factory built fireplace, the following instructions must be
carefully followed:
(1) Sidewall Clearances:
Clearance from the side of the fireplace opening to any adjacent combustible wall
should not be less than: right side 7", left side 7".
(2) Ceiling Clearances:
The ceiling height should not be less than 24" from the top of the fireplace opening.
(3) Mantel Clearances:
Clearances from top of heater to mantel or mantel supports should not be less than 20".
NOTE: See the following sections for installation options: Section III, page 24, Installation In A SolidFuel Burning Fireplace, and Section IV, page 26 Freestanding Installation, and Section V, page 28
Alcove Installation, and Section VI, page 29 Optional Wooden Mantel Installation
WAR NI NG : ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.
GAS CONNECTION
Check gas type. Use only the type of gas indicated on the valve rating plate. If the
type of gas listed on the plate is not your type of gas supply, DO NOT INSTALL.
for proper model.
Always use an external regulator for all LP heaters to reduce the supply tank pressure to a maximum of
13" W.C. This is in addition to the regulator furnished with the heater.
WA RN I NG : CONNECTION DIRECTLY TO AN UNREGULATED LP TANK CAN CAUSE
AN EXPLOSION.
The normal gas connection is 3/8” N.P.T. made at the left side (facing the front of the appliance) of the
appliance. If a right side connection is desired, the connecting pipe may be led under the rear of the
burner base to terminate at the right side for connection to the inlet of the valve.
NOTE: The connecting pipe must be internally tinned copper tubing for use with natural gas. Test for
leaks using a solution of soap and water after completing the connection. DO NOT USE OPEN
FLAME.
NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch
(37.5mm) diameter or less may be drilled through the lower sides or bottom of the fire box in a proper
workmanlike manner. This access hole must be plugged with non-combustible insulation after the gas
supply line has been installed.”
WARNING: Installation and repairs should be performed by a qualified service person. The
appliance should be inspected before use and at least annually by a professional service person.
More frequent cleaning may be required due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments, burners and circulating air passageways of the
appliance be kept clean.
Contact your dealer
Page 10
CR3329 CERAMIC LOG SET PLACEMENT FOR MODEL 329
Page 6
(1-L)
(4)
(3)
(2)
(1-R)
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only
parts specifically approved with this heater may result in property damage or personal injury.
WARNING: POSITIONING OF LOGS IS VERY CRITICAL (SEE DIAGRAM ABOVE).
(1) Front Log #1 (Slim Log wrapped in cardboard box) . Place the log between front portion of
burner and log grates.
(2) Middle Glow Log #2 . Place rear of log on top of middle log supports located in open center por-
tion of burner base. Front of log should rest slightly behind the rear line of burner holes on the
front portion of the burner. Align the Notch on the left front bottom side of the log over the existing hold down nut of the burner. This should align the log at the right position from left or right
on the burner.
(3) Rear Log #3. Place log in rear log supports center from left to right.
(4) Left Top Log #4. Log has two (2) holes in the bottom front side. Align the holes with the two (2)
pins located on the left top of log #2. Rear of log #4 should rest on the left top end of the rear log
#3.
Page 11
EMBER STOVE LOG SET PLACEMENT FOR MODEL 329
Page 7
3
2
1
4
5
6
7
“MILLIVOLT ONLY”
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only
parts specifically approved with this heater may result in property damage or personal injury.
WARNING: POSITIONING OF LOGS IS VERY CRITICAL (SEE DIAGRAM ABOVE).
MODEL E.S.B: 1)Rear Log, 2)Middle Log, 3)Left Top Middle Log, 4)Right Top Middle
Log 5)Left Front Log 6)Right Front Log 7)Glowing Embers in front of 5 & 6 logs.
WARNING: POSITIONING OF LOGS IS VERY CRITICAL (See Figure 2).
LOG PLACEMENT FOR E.V. 100 Series 24” OAK OR PINE LOG SET:
1) Place rear log #1 on rear log supports. The log has alignment notches on each rear corner.
2) Place Middle log #2 in front of the rear burner tube and then move the log forward. The log
should seat just behind the brass knob(s), located in the middle section of the base between the rear
burner tube and the front burner pan.
3) Place Left Top Middle log #3 on the pins located on the left top section of Middle log #2.
4) Place Right Top Middle log #4 on the pin located on the right top section of Middle log #2 and a
line the notch on the right side #4 with the side shield on the right.
5) Place Left Front log #5 on the locator pins located on the left middle section of the front burner
pan.
6) Place Right Front log #6 on the locator pins located on the right middle section of the front
burner pan.
7) Provided with your log set is a package of Glowing Embers (rock wool). Open the package and
tare off small pieces of the wool material and place it over the small holes (ports) located on the
front burner pan in front of logs #5 and #6. Cover the entire section of holes (ports).
*Replacement of loose (Glowing Embers) must be purchased from the original manufac-
turer and application of excess loose material may adversely affect performance of the
heater.
NOTE: “Wash your hands immediately after coming in contact with the wool material. The
wool can cause slight itching or burning in some cases, avoid any contact with eyes.”
“WARNING: All previously applied loose material must be removed prior to replacement.”
Page 12
GAS PRESSURE CHECK
Page 8
Check the inlet pressure to the burner to ensure that it is as shown in the table below.
NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT
Millivolt, and the left side for SIT Modulating.
The appliance and its appliance main gas valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psi
(3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shut
-off valve during any pressure testing of the gas supply piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
Maximum Heat Input 33,000 33,000 33,000 33,000
Minimum Heat Input 23,000 23,000 12,000 13,000
Gas Inlet Pressure
Maximum 10.5ins.W.C. 13ins.W.C. 10.5ins.W.C. 9.0ins.W.C.
Minimum * 5.0ins.W.C. *11ins.W.C. *5.0ins.W.C. *11ins.W.C.
Manifold Pressure
Maximum 3.5ins.W.C. 9.0ins.W.C. 3.5ins.W.C. 9.0ins.W.C.
Minimum 3.0ins.W.C. 8.2ins.W.C. 2.8ins.W.C. 7.2ins.W.C.
NOTE: On initial installation it may be necessary to bleed out air in the gas lines. Do this by
holding the control knob and turning the knob to the “PILOT” position for about 30 seconds.
To check the regulator pressure, remove the pressure tag plug at the left side of the regulator
facing the heater. The pressure should be checked with the heater burning and the control set
on high. After measuring the pressure, replace the pressure tap plug, ensuring that there are no
leaks.+
* For the purpose of minimum input adjustment.WA RN I NG
This appliance is equipped for (natural or propane) gas.
Field conversion is not permitted.
Solid fuels shall not be burned in the same fireplace where an unvented room heater has
been installed.
NOTE: The following label has been provided with this appliance and must be read and
then attached to the floor of the fireplace or firebox area beneath the appliance.
The label is a peel and stick label. Make sure the area is cleaned before attaching
the label to it.
“WARNING: This solid-fuel burning fireplace or listed ventless enclosure has been
converted for use with an unvented fireplace insert only. A solid-fuel burning
fireplace cannot be used for burning wood or solid fuels unless all original parts
have been replaced, and the fireplace re-approved by the authority having
jurisdiction. A ventless firebox enclosure cannot be used with an unvented gas log
unless all original parts have been replaced, and the ventless firebox enclosure reapproved by the authority having jurisdiction.”
Page 13
LIGHTING INSTRUCTIONS
Page 9
MI LLIVO LT VALVE ( ITT )
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY,
OR LOSS OF LIFE.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell around the appliance for gas. Be sure to smell next to the
floor because gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
♦ Do not try to light any appliance.
♦ Do not touch any electrical switch; do not use any phone in your building.
♦ Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
♦ If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob
will not push in or turn by hand, don’t try to repair it, call a qualified service technician.
Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system and
any gas control which has been under water.
Page 14
LIGHTING INSTRUCTIONS
Page 10
1. STOP! Read the safety information on previous page.
2. Make sure the manual shutoff valve is fully closed. If equipped with thermostat set to the lowest
setting.
3. Turn off all electrical power to the appliance.
4. Open access panel door located at bottom front of the appliance.
5. Turn control knob clockwise to the full “OFF” position.
ROCKER SWITCH
OFF
ON
PIEZO
THERMOSTAT
IGNITOR ELECTRODE
THERMOGENERATOR
THERMOPILE
9080706050
PILOT BURNER
BURNER
PILOT
PILOT ASS'Y
CONTROL KNOB
ITT VALVE
PILOT
ADJ
T
O
L
I
P
OFF
P
TO
RE
S
S
O
N
T
E
S
E
R
THERMO GEN
AUX
CONTROLS
ITT
GENERAL
BEFORE INSTALLING THERMOSTAT
REMOVE METAL CONNECTOR
When hooking up a Wall Thermostat to valve, remove the Jumper Bar. Do not remove the existing
wires, simply add the wire from the Wall Thermostat to screws (one wire to each screw).
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety informationon the previous page.If you don’t smell
gas, go to the next step.
7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of the
appliance. Fully open the manual shutoff valve.
8. Push the ON/OFF toggle switch to “OFF” (rocker switch).
9. Turn gas control knob counterclockwise to the “PILOT” position.Press in gas control
knob for fifteen (15) seconds.
10. With control knob pressed in , push down (in) and release the ignitor button (ignitor button is
located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep
repeating this step until pilot lights.
11. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute, release the
gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 1
through 9.
• If the knob does not pop up when released, stop and immediately call your service technician or
gas supplier.
Page 15
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF”
Page 11
and call your service technician or gas supplier.
IGNITOR ELECTRODE
THERMO-COUPLE
THERMO-PILE
12. Turn control knob counterclockwise to the “ON” position. Push the “ON/OFF”
toggle switch to the “ON” position. The main burner should light.
13. Close access panel door.
14. Turn on all electrical power to the appliance.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall
Thermostat needs to be set at a higher temperature than the room temperature.
TO TURN OFF GAS TO
PILOT BURNER
APPLIANCE
SHUTTING OFF UNIT
1. Open access panel door located at bottom front of the appliance.
2. “If equip with thermostat set to lowest setting.”
3. Turn control knob clockwise to the “OFF” position.
4. Turn off all electric power to the appliance if service is to be performed.
5. Close access panel door.
SHUTTING OFF BURNER ONLY (Pilot stays lit.)
Turn control knob clockwise to the “PILOT” position.
CAUTION
DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL
SHUTOFF VALVE.
Page 16
THERMOSTAT CONTROL OPERATION
Page 12
• This valve operates off of millivolts produced by the generator. You may choose to use an
optional Wall Thermostat or Remote control. If so, see Figure 2, page 11 for wiring diagram.
MANUAL LIGHTING PROCEDURE
1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match
and a lighter rod.
2. Open access panel door located at bottom front of the appliance.
3. Place the match in the holder and light. With the left hand, turn the control knob
counterclockwise to “PILOT”position. Press in gas control knob for fifteen (15)
seconds.
4. Use rod to light match and ignite pilot. The pilot is located in front of the rear log and burner
on the right hand side of the appliance.
5. Continue to hold the control knob for an additional one (1) minute to ensure the pilot is lit.
6. Turn control knob counterclockwise to the “ON” position. Push the “ON/
OFF” toggle switch to the “ON” position. The main burner should light.
7. Close access panel door.
8. Turn on all electrical power to the appliance.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall Thermostat needs
to be set at a higher temperature than the room temperature.
12
Page 17
LIGHTING INSTRUCTION
Page 13
MODULATING OR MANUAL VALVE (SIT)
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.”
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to
the floor because gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup-
plier’s instructions.
• If you cannot reach your gas supplier, call the fire department.”
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob
will not push in or turn by hand, don’t try to repair it’ call a qualified service technician.
Force or attempted repair may result in a fire or explosion.”
D. Do not use this appliance if any part has been under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to replace any part of the control system and
any gas control which has been under water.”
Page 18
LIGHTING INSTRUCTION
Page 14
1. STOP! Read the safety information on preceding page 13.
2. Make sure manual shutoff valve is fully closed.
3. Turn off all electrical power to the appliance.
4. Open access panel door located at bottom front of the appliance.
5. Turn control knob clockwise to the full “OFF” position.
Ignitor Button
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” on preceding page in the Safety Information. If you
don’t smell gas, go to the next step.
7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of
the appliance. Fully open the manual shutoff valve.
8. Press in and turn gas control knob counterclockwise to the “PILOT” position continue pressing in control knob for fifteen (15) seconds.
9. With control knob pressed in, push down (in) and release the ignitor button (ignitor button
is located on the left hand side of the gas control valve) . This will light pilot. If needed,
keep repeating this step until pilot lights.
10. Keep control knob pressed in for one (1) minute after lighting pilot. After one (1) minute,
release control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat
steps 1 through 9.
• If the knob does not pop up when released, stop and immediately call your service techni-
cian or gas supplier.
• “If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call
your services technician or gas supplier.”
Page 19
Page 15
11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the
gas control knob counterclockwise to your desired setting.
12. Close access panel door.
13. Turn on all electrical power to the appliance.
CAUTION
DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF
VALVE.
TO TURN OFF GAS TO APPLIANCE
SHUTTING OFF UNIT
1. Open access cover door.
2. Turn gas control knob clockwise to the full “OFF” position.
3. Turn off all electric power to the appliance if service is to be performed.
4. Close access cover door.
SHUTTING OFF BURNER ONLY (pilot stays lit)
Turn control knob clockwise to the “PILOT” position.
CAUTION: Hot while in operation. Do Not Touch. Keep children, clothing, furniture,
gasoline, and other liquids having flammable vapors away.
CAUTION: DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE
MANUAL SHUTOFF VALVE.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury, or loss of life. Refer to owner’s information manual
provided with this appliance. Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
IMPORTANT: Always operate the appliance at the completely “ON” or the completely
“OFF” positions. Never use the heater at a setting between these positions as this can result in
improper combustion and excessive carbon monoxide emissions.
Page 20
THERMOSTAT CONTROL OPERATION
Page 16
1. The thermostat control on this heater differs from standard thermostats. Standard
thermostats simply turn the burner on and off. The thermostat used on this heater
senses the room temperature and adjusts the amount of gas flow to the burner. This
will increase or decrease the flame height. At times, the room may exceed the set
temperature, which will cause the burner to shut off. When room temperature drops
below the thermostat setting, the burner will cycle itself on again. The control knob
can be set to any level between “LO” and “HI”.
NOTE: The thermostat sensing bulb measures the temperature of air near the
heater cabinet. This may not always agree with room temperature (depending on
housing construction, installation location, room size, open air temperatures,
etc.). Frequent use of your heater will allow you to determine your personal
comfort levels.
MANUAL LIGHTING PROCEDURE
1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper
match and a lighter rod.
2. Open access panel door located at bottom front of the appliance.
3. Place the match in the holder and light. With the left hand, turn the control knob
counterclockwise to “PILOT”position. Press in gas control knob for fifteen
(15) seconds.
4. Use rod to light match and ignite pilot. The pilot is located in front of the rear log and
burner on the right hand side of the appliance.
5. Continue to hold the control knob for an additional one (1) minute to ensure the pilot is
lit.
6. Turn control knob counterclockwise to the “ON” position. Push the
“ON/OFF” toggle switch to the “ON” position. The main burner should light.
7. Close access panel door.
8. Turn on all electrical power to the appliance.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall Thermostat
needs to be set at a higher temperature than the room temperature.
Page 21
Page 17
OPERATING INSTRUCTIONS
Before operating this appliance, proceed through the following checklist.
1. Read and understand these instructions before operating this appliance.
2. Check that there are no gas leaks. If you smell gas do not attempt to light this appliance.
3. Verify that log placement is correct.
LIGHTING INSTRUCTIONS
SI T-MILL IVOLT VALV E
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury, or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot follow
these instructions exactly. If piezo fails, then light the pilot using matches. Refer to the match
lighting instructions.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air and will settle to the floor.
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch; do not use any phone in your building.
* Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
* If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it. Call a qualified service technician. Force or
attempted repair may result in a fire or explosion.”
D. Do not use this appliance if any or part of it has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the control system
and any gas control which has been under water.”
Page 22
Page 18
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on page 17.
2. Make sure manual shutoff valve is fully closed. If equipped with thermostat, set to the low-
est setting.
3. Turn off all electrical power to the appliance.
4. Open access cover door located at the bottom of the front of the appliance.
5. Push in gas control knobslightly and turn clockwise to the full “OFF” position.
REMOTE CONTROL OR
WALL THERMOSTAT
NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do
not force.
6. Wait (5) five minutes to clear out any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the safety information on the reverse side of this label.
If you don’t smell gas, go to the next step.
7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of
the appliance. Fully open the manual shutoff valve.
8. Press in and turn knob on gas control counterclockwise to “PILOT” and continue
pressing in the knob for (15) fifteen seconds.
9. With control knob pressed in push down (in) and release the ignitor button (ignitor button is
located on the left hand side of the front of the appliance). This will light the pilot. If
needed, keep repeating this step until pilot lights.
10. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute,
release the control knob and it will pop back up. Pilot should remain lit. If pilot goes out,
repeat steps 1 through 9.
• If the knob does not pop up when released, stop and immediately call your service
technician or gas supplier.
Page 23
* If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call
Page 19
your service technician or gas supplier.
11. Turn control knob counterclockwise to “ON”.
12. If using unit without wall thermostat place Auto/Off/Manual switch into the manual
position. If using wall thermostat place Auto Off Manual Switch into the auto position and
place thermostat to a setting higher than the room temperature.
13. Close access door.
14. “Turn on all electrical power to the appliance.”
15. Your heater is equipped with a HI & LO control. Turn clockwise for Low and
counterclockwise for High.
CAUTION
DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF
VALVE.
TO TURN OFF GAS TO
APPLIANCE
SHUTTING OFF UNIT
1. Open access cover door.
2. “If equipped with thermostat set to lowest setting.”
3. Turn control knob clockwise to the full “OFF”.
4. Turn off all electric power to the appliance if service is to be performed.
5. Close access cover door.
SHUTTING OFF BURNER ONLY (Pilot stays lit.)
Turn control knob clockwise to the “PILOT” position.
CAUTION: Hot while in operation. Do Not Touch. Keep children, clothing, furniture,
gasoline, and other liquids having flammable vapors away.
CAUTION: DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE
MANUAL SHUTOFF VALVE.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury, or loss of life. Refer to owner’s information manual
provided with this appliance. Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
IMPORTANT: Always operate the appliance at the completely “ON” or the completely
“OFF” positions. Never use the heater at a setting between these positions as this can result in
improper combustion and excessive carbon monoxide emissions.
Page 24
MANUAL LIGHTING PROCEDURE
Page 20
1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper
match and a lighter rod.
2. Open access panel door located at bottom front of the appliance.
3. 2. Place the match in the holder and light. With the left hand, turn the control knob
counterclockwise to “PILOT”position. Press in gas control knob for fifteen
(15) seconds.
4. Use rod to light match and ignite pilot. The pilot is located in front of the rear log and
burner on the right hand side of the appliance.
5. Continue to hold the control knob for an additional one (1) minute to ensure the pilot is
lit.
6. Turn control knob counterclockwise to the “ON” position. Push the
“ON/ OFF” toggle switch to the “ON” position. The main burner should light.
7. Close access panel door.
8. Turn on all electrical power to the appliance.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall Thermostat
needs to be set at a higher temperature than the room temperature.
Page 25
FLAME CHECK
Page 21
A periodic check of the flames should be made. The
pilot flame should always be present when the gas logs are in operation.
Rear Flames: The flames at the rear or at either side of the top log should be very similar, yellow in
color, and should be about 3" to 4" above the large rear log for natural gas logs and about 6"
for propane (LP) gas log sets.
Front Flame: The flame should be 1-1/2" to 2" high and touch the back of front log. This will
produce a red glow on this log.
CR 3329 LOG SET
Natural
PILOT
Propane
E.S.B. LOG SET
PILOT
WHEN USED AS A HEATING
APPLIANCE
HEAT OUTPUT
When used as a ventless heater, the flue damper of a solid-fuel burning non-combustible fireplace
must always be closed.
The heat output is controlled by the “ON/OFF” switch or wall thermostat, when using the Millivolt
Valve. When using the -SIT Modulating or -SIT Manual Valve the heat output is controlled by the
dial with LOW to HIGH settings. The Vent-Free fireplace may be installed where permitted by local,
state, and city codes.
In the absence of local codes, the latest edition of the National Fuel Gas Code (ANSI Z223.1) must be
met.
Page 26
WIRING DIAGRAM
Page 22
MOTOR
JUMPER
GREEN
POWER CORD
JUMPER
WHITE
THERMOSTAT
JUMPER
BLACK
RHEOSTAT
BLACK
Figure 6
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE
APPLIANCE
WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE
MATERIAL ON OR NEAR THE APPLIANCE.
NOTE: “If any of the original wire as supplied with the gas appliance must be
replaced, it must be replaced with a wire of at least a 105
NOTE: Installation and repair should be done by a qualified service person.
This heater should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative that control compartments
and circulating air passageways of the heater be kept clean.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation.
Verify proper operation after servicing.
o
C. temperature rating.”
Page 27
WARNING:
Page 23
ELECTRICAL GROUNDING INSTRUCTION:
THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG
FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG
RECEPTACLE.
NOTE: #PESBR084 Blower Motor
Rating: 120 volts/60HZ/1.1 Amps.
See Figure 6, page 22 for wiring diagram.
NOTE: For convenience, allow licensed electrician to install properly grounded
3-plug receptacle near unit.
ROOM BLOWER INSTALLATION AND OPERATION INSTRUCTIONS
The room air blower is located at the rear of the unit in the bottom chamber. To remove or
replace blower, open lower louvered access door. The motor is located right center in rear.
Remove the two (2) hex head screws holding the motor and motor bracket to the outer bottom
of the unit. Unhook the two motor wires and remove the motor from the unit. Next remove the
(2) screws that fasten the motor bracket to the motor. Locate the motor bracket on the new
motor in the same position as with the old. Using the two (2) hex head screws fasten the
bracket to the new motor. Place new motor into the lower compartment.
NOTE: Make sure the motor opening 1"x 5" is behind the inner wall of the stove and not
touching any metal. Fasten the new motor and bracket to the motor support on the bottom of
the unit. Hook the motor wires as shown in the diagram on page 22.
Installation and repairs should be performed by a qualified service person. The appliance should
be inspected before use and at least annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is
imperative that control compartments, burners and circulating air passageways of the appliance
be kept clean.
Page 28
SECTION III
Page 24
INSTALLATION MODEL 329 (FP)
IN SOLID FUEL BURNING FIREPLACES
(1) The Model 329 (FP) may be installed in a masonry fireplace. The minimum fireplace
dimension must be 24" high, 29-1/2" wide, and 6" deep.
(2) For minimum dimensions for the sidewall and mantel, see Figure 7.
(3) Center the heater in fireplace opening.
(4) NOTE: See “Producing Adequate Ventilation” page 32.
NOTE: The installer of this appliance must mechanically (peel and stick) attach the marking
supplied with this unvented appliance before installing to the inside of the firebox of the solid-fuel
burning fireplace or listed ventless firebox enclosure into which the unvented fireplace insert is
installed. See the example of the marking on page 8 of this manual.
CAUTION: Cutting any sheet-metal parts of the solid-fuel burning fireplace or listed ventless
enclosure in which the unvented fireplace is to be installed is prohibited.
NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch
(37.5) diameter or less may be drilled through the lower sides or bottom of the firebox in a proper
workmanlike manner. This access hole must be plugged with non-combustible insulation after the
gas supply line has been installed.”
“Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applicable)
can be removed from the fireplace before installing the unvented fireplace insert.”
“Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.”
“ Trim panels or surrounds shall not seal ventilation openings in the fireplace.”
NOTE: After the unit is positioned in fireplace, mark the trim panels as follows:
A. Set the side panels in place, flat against the fireplace. Mark down the inside edge of the trim
panel to make a vertical reference line.
LEFT SIDE
7"
24"
6"
Figure 7
24"
20"
RIGHT SIDE
29-1/2"
Page 29
B. Set the top (long) trim panel in place on top of unit. The panel should be flat against the
Page 25
outside face of the fireplace, and standing vertically. Mark along the lower edge of the trim
panel with a pencil to make reference line for mounting.
(4) Slide the unit out of the fireplace far enough to work behind the trim panel reference lines with a
screw gun.
NOTE: You need to make sure the supply gas line is hooked up at this time. Be sure
to check for leaks at the connection using soap and water. DO NOT USE OPEN FLAME TEST FOR LEAKS.
(5) With screws provided with fireplace kit, attach both side trim panels. Next, attach top trim
panels.
(6) Slide the heater back into the fireplace with the trim panels flat against the face of the fireplace.
(7) After hooking up gas line, checking for leaks, and mounting trim panels slide heater into
fireplace.
(8) Place logs on burner base as shown on page 6. or 7.
(9) For gas hook-up and pressure tap test, see instruction in Section II.
WARNING: Solid-Fuels shall not be burned in a fireplace in which an unvented room heater is
installed.
CAUTION: Any outside air ducts and/or ash dumps in the fireplace shall be permanently closed at
time of appliance installation.
WARNING: Before installing in a solid-fuel burning fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.
Page 30
O
SECTION IV
Page 26
MODEL 329(FS)
FREESTANDING INSTALLATION
(1) Determine the exact position of your gas heater.
NOTE: Due to high temperatures, this heater should be located out of traffic areas and
away from furniture and draperies.
NOTE: For safe installation the minimum clearances must be met. See Figure 9.
0"
WALL
0"
REAR WALL
WALL
0"
CORNER INSTALLATI
LEFT
WALL
REAR WALL
NOTE:
DIMENSIONS SHOWN ARE
MINIMUM CLEARANCE TO
COMBUSTIBLE WALL.
4”
7"
FACING UNIT
STOVE
0"
7"
RIGHT
WALL
Figure 10
CEILING
42"
26"
SIDE VIEW
Figure 9
CAUTION: The installation must conform with local codes ,or in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.
NOTE: See Section II for gas hookup and pressure check.
(2) Make sure you have the right valve for your type of gas. Check label on side of valve. Position
logs as shown in Log Placement Section, Page 6. Or 7. Position screen before leaving heater
unattended.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
WA RN I NG : “Young children should be carefully supervised when they are in the same
room with the appliance.” “
face temperature and should stay away to avoid burns or clothing ignition.”
Children and adults should be alerted to the hazards of high sur-
WA RN I NG : When the appliance is installed directly on carpeting, tile or other combus-
tible material, other than wood flooring, the appliance shall be installed on a metal or
wood panel extending the full width and depth of the appliance.
Page 31
FREESTANDING PEDESTAL
Page 27
INSTALLATION
(1) Lay the heater on its back (use a drop-cloth to protect the back of the heater and the surface
of your flooring). Place pedestal against bottom of heater. Center pedestal from left to right
and from front to rear. Mark the holes on the angle on the top of the pedestal. Lay the
pedestal aside. Drill the marks. Replace the pedestal and secure with the provided screws.
(2) Stand heater to the upright position. Place heater in the desired location. At this point you
may want to secure the pedestal to the floor with screws or an “ell” bracket.
(3) Hook up gas supply line. Check for leaks with mild soapy water. See page 5, Installation
Clearances and Gas Connection.
Page 32
Page 28
SECTION V
MODEL 329
ALCOVE INSTALLATION
CAUTION: READ ENTIRE MANUAL BEFORE INSTALLING HEATER.
(1) For clearances, see Figure 10. The minimum must be met.
(2) For Installation and Gas Hookup Connection see Section II.
CAUTION: The installation must conform with local codes ,or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/NFPA54.
WARNING: DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE ROOM HEATER AND TO REPLACE ANY PART
OF THE CONTROL SYSTEM AND GAS CONTROL WHICH HAS BEEN
UNDER WATER.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE PERSONAL INJURY OR
LOSS OF LIFE. PROPERTY DAMAGE. REFER TO THIS MANUAL.
WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN
BE DANGEROUS.”
LEFT
WALL
REAR WALL
NOTE:
DIMENSIONS SHOWN ARE
MINIMUM CLEARANCE TO
COMBUSTIBLE WALL.
7"
FACING UNIT
STOVE
0"
7"
RIGHT
WALL
CEILING
0"
26"
REAR WALL
Figure 10
SIDE VIEW
Page 33
Page 29
INSTALLATION OF MODEL 329 (WS) WITH
OPTIONAL WOODEN SURROUND (KIT#PAKDFP34)
See page 24, figure 7 for Clearances to Combustible Materials.
(1) When choosing the right location for your heater and mantel keep the following in mind:
NOTE: Due to high temperatures, this heater should be located out of traffic areas
and away from furniture and draperies.
CAUTION: The installation must conform with local codes ,or in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.
NOTE: See Section II for gas hookup and pressure check.
WAR NI NG : “Young children should be carefully supervised when they are in the same
room with the appliance.” “Children and adults should be alerted to the hazards of high
surface temperature and should stay away to avoid burns or clothing ignition.”
(2) Position screen before leaving heater unattended.
(3) Follow instructions for assembly of Wooden Surround (Mantel) supplied with the mantel.
TOOLS NEEDED: Medium Phillips screwdriver, tape measure, power drill, and 5/16" socket.
STEP 1: Lay out all components.
STEP 2: Assemble end panels A & B to top front rail C.
STEP 3: Stand end panels and top front rail into hearth.
NOTE: (Position back of end panels with back of hearth centering assembly from
each end). Install front screws first, then pull back towards the inside to square the
mantel. Install screws through back holes.
STEP 4: The owner must decide at this time if parts D, E, and F are to be wood or green. Beginning
with panel E stand chosen color face out on hearth flush against stop block located inside end panel A
and attach. Position the left end of top window D on top of E and attach. Slide panel F under the
right end of D and attach.
SECTION VI
END PANEL A
END PANEL B
E
F
END PANEL A
END PANEL
B
Page 34
STEP 5: After mantel has been assembled, take metal strips out of box supplied with mantel.
Page 30
Position the side strips on each side of your 329 with a maximum of 9 3/4" from back of stove
to the edge of your metal strip. Attach with self tapping screws.
STEP 6: Take the top strip and screw it to the top of your 329 overlapping your side panels on
it.
STEP 7: Place a cloth or blanket over the front portions of mantel as not to scar the wooden
part of the mantel.
STEP 8: Take fireplace and slide it into the opening of the mantel from the front side. Slide it
in far enough that the edge of the side and the top panels snug up against the front side of your
mantel. Center up.
STEP 9: Remove cloth or blanket from underneath stove.
STEP 10: Take the two metal “ell” brackets with the screws provided and anchor the back of
the fireplace to the mantel.
STEP 11: Place top on to the mantel, flush with the back and equal on each end. Secure both
ends and middle with screws.
Installation and repairs should be performed by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person.
More frequent cleaning may be required due to excessive lint from carpeting, bedding
material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
This appliance may be installed in an After Market* Manufactured Mobile Home, where not
prohibited by state or local codes.
• (After Market: Completion of sale, not for the purpose of resale from the manufacturer).
For mobile home installation instruction follow instructions provided in this manual
completely.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
NOTE: See section VIII for “Producing Adequate Ventilation”.
Page 36
PRODUCING ADEQUATE
Page 32
VENTILATION
This section is for residential or manufactured (mobile) installation
“This heater shall not be installed in a confined space or unusually tight construction unless provisions are adequate combustion and ventilation air.”
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space
whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8m 3 per kw) of the
aggregate input rating of all appliances installed in that space and an unconfined space as a
space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8m
the aggregate input rating of all appliances installed in that space. Rooms communicating
directly with the space in which the appliances are installed, through openings not furnished
with doors, are considered a part of the unconfined space.
“WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS
SMALLER THAN THAT DEFINED AS AN UNCONFINED SPACE OR IF THE
BUILDING IS OF UNUSUALLY TIGHT CONSTRUCTION, PROVIDE ADEQUATE
COMBUSTION AND VENTILATION AIR BY ONE OF THE METHODS DESCRIBED
IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, SECTION 5.3 OR
APPLICABLE LOCAL CODES.”
Unusually tight construction is defined as construction where:
a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder
with a rating of 1 perm (6 x 10
b) Weather stripping has been added on openable windows and doors, and
c) Caulking or sealants are applied to areas such as joints around window and door frames,
between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations
for plumbing, electrical, and gas lines, and at other openings.
-11
kg per pa-sec-m2) or less with openings gasketed or sealed;
3
per kw) of
NOTE: SOME AREAS IN THE UNITED STATES HAVE HIGHER REQUIREMENTS
FOR CUBIC FEET PER 1000 BTU/ HOUR INPUT. (EX. CINCINNATI, OHIO CODES
REQUIRE 70 CUBIC FEET). CHECK YOUR LOCAL CODE BEFORE
INSTALLATION.
DETERMINING FRESH-AIR FLOW FOR
HEATER LOCATION
DETERMINE IF YOU HAVE A CONFINED OR UNCONFINED SPACE
Use this worksheet to determine if you have confined or unconfined space.
SPACE: Includes the room in which you will install heater plus adjoining rooms with
doorless passageways or ventilation grills between the rooms.
Page 37
Page 33
1. Determine the volume of the space (length x width x height).
Length x Width x Height =_________cu.ft.(volume of space)
EXAMPLE: 20 ft.(Length) x 16 ft.(Width) x 8 ft.(ceiling Height)=
2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the
volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum BTU/Hr the
space can support.
_________(volume of space)/50 cu. ft. =maximum BTU/Hr the space can support)
EXAMPLE: 2560 cu. ft. (volume of space /50 cu. Ft .= 51.2 or
51200 (maximum BTU/Hr the space can support)
3. Add the BTU/Hr of all fuel burning appliances in the space.
Vent-free heater _______________BTU/Hr
Gas water heater* _______________BTU/Hr
Gas furnace _______________BTU/Hr
Vented gas heater _______________BTU/Hr
Gas fireplace logs _______________BTU/Hr
Other gas appliances* + _______________BTU/Hr
Total = _______________BTU/Hr
Example: Gas water heater 40000 BTU/Hr
Vent-free heater + 18000 B
TU/Hr
Total = 58000 BTU/Hr
*Does not include direct-vent gas appliances. Direct-vent draws combustion air
from the outdoors and vents to the outdoors.
4. Compare the maximum BTU/Hr the space can support with the actual amount of BTU/
Hr used.
____________BTU/Hr (maximum the space can support)
____________BTU/Hr (actual amount of BTU/Hr used)
Example: 51200 BTU/Hr (maximum the space can support)
58000 BTU/Hr (actual amount of BTU/Hr used)
The space in the above example is a confined space because the actual BTU/Hr used is more
than the maximum BTU/Hr the space can support. You must provide additional fresh
air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining
room. If the extra space provides an unconfined space, remove door to adjoining room or add
ventilation grills between rooms. See “Ventilation Air From Inside Building”, page 34.
B. Vent room directly to the outdoors. See “Ventilation Air From Outdoors”, page 35.
C. Install a lower BTU/Hr heater, if lower BTU/Hr size makes room unconfined.
If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the
space is an unconfined space. You will need no additional fresh air ventilation.
WAR NI NG : YOU MUST PROVIDE ADDITIONAL VENTILATION AIR IN A
CONFINED SPACE
Page 38
VENTILATION AIR
Page 34
VENTILATION AIR FROM INSIDE BUILDING
This fresh air would come from an adjoining unconfined space. When venting to an adjoining space,
you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces. (See Options 1 and 2, Figure 11.) You can also remove
door into adjoining room. (See Option 3, Figure 11.)
WARNING
REWORK WORKSHEET, ADDING THE SPACE OF THE ADJOINING UNCONFINED
SPACE. THE COMBINED SPACES MUST HAVE ENOUGH FRESH AIR TO SUPPLY ALL
APPLIANCES IN BOTH SPACES.
NOTE: Each opening shall have a minimum free area of 1 square inch per 1000
BTU’s per hour of the total input ratings of all gas utilization equipment in the confined
space, but not less than 100 square inches.
Figure 11 Ventilation Air From Inside Building
Page 39
VENTILATION AIR FROM OUTDOORS
Page 35
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent
openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly
to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, “Air For Combustion and Ventilation” for required size of
ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet air into attic if attic has a
thermostat-controlled power vent. Heated air entering the attic will activate the power
unit.
Ventilated Attic
Outlet Air
Outlet Air
Inlet Air
Inlet Air
To Attic
To
Crawl
Space
Ventilated
Crawl Space
Figure 14 - Ventilation Air From Outdoors
WARNING
THIS APPLIANCE MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT,
POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING
INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUELBURNING APPLIANCES IN YOUR HOME.
Page 40
IMPORTANT SAFEGUARDS
Page 36
Although your gas logs are very realistic in appearance, it is not a real burning fireplace and must not be
used for burning rejected material.
• To avoid irreparable damage to the heater or personal injury, matches, paper, garbage, or any other
material must not be placed or thrown on top of the logs or into the flames.
• To avoid personal injury, do not touch hot surfaces when the heater is operating.
• Close supervision is necessary when the heater is being operated near children.
WARNING: THE LOGS ARE MANUFACTURED FROM
BONDED CERAMIC FIBER. THIS IS A COMMONLY USED
MATERIAL IN INDUSTRY WORLDWIDE. IN THE EVENT THAT A
LOG SHOULD BE REMOVED, CARE SHOULD BE TAKEN NOT TO
DAMAGE THE BONDED MATERIAL.
INTENTIONAL MISUSE OR DELIBERATELY FRAGMENTING THE
MATERIAL COULD LEAD TO INHALING FIBERS AND BE
HAZARDOUS TO YOUR HEALTH.
THIS HEATER IS INTENDED FOR USE AS A GAS HEATER
FIREPLACE AS DESCRIBED IN THESE INSTRUCTIONS. IT SHOULD
NOT BE USED FOR ANY OTHER PURPOSE.
CLEANING
CAUTION: BEFORE CLEANING OR MOVING THESE LOGS OR
OTHER PARTS OF THE HEATER, BE SURE TO READ THE ABOVE
SECTIONS ON “IMPORTANT SAFEGUARDS.”
The appliance must be turned “OFF” before cleaning inside the firebox (burn
area), make sure the pilot is “OFF” completely and the appliance has cooled.
• All cleaning should be carried out when the heater is cold. Limited cleaning is required
with normal use. Dusting the front of the base, the top of the piezo cover, or the control
knob panel may be required occasionally. Do not use cleaning fluids to clean the logs or
any other part of the heater.
• If the flames show unusual shapes or behavior, or if burner fails to ignite properly, the
burner holes may require cleaning. If this occurs, contact your nearest dealer to service the
heater.
• The heater can be cleaned by removing the logs. Lift the logs gently, as not to damage the
fiber pieces. The logs have been spot glued in place for shipping, use caution when
removing. Lift each log by holding it carefully at each end. Use a vacuum cleaner to
remove dust and loose particles from the base, logs and around the burner and ODS/Pilot.
Gloves are recommended to prevent fibers from breaking the skin. If skin is broken, clean
with soap and water.
WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in
sooting and property damage.
Page 41
TROUBLESHOOTING
Page 37
WARNING
TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING.
ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR
HEATER.
CAUTION
NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN ODS/
PILOT. THIS CAN DAMAGE ODS/PILOT.
OBSERVED
PROBLEM
Igniter button is pressed no
spark at ODS/Pilot
OBSERVED
PROBLEM
Igniter button is pressed
Spark at ODS/Pilot
No Ignition
POSSIBLE
CAUSE
1. Igniter electrode positioned
incorrectly
2. Igniter electrode broken
3. Igniter electrode not
connected to igniter cable
4. Igniter cable pinched or wet
5. Piezo igniter nut is loose
6. Broken igniter cable
7. Bad piezo igniter
POSSIBLE
CAUSE
1. Gas supply turned off or
manual shutoff valve is
closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
SOLUTION
1. Replace igniter
2. Replace igniter
3. Reconnect igniter cable
4. Free igniter cable if pinched
by any metal or tubing. Keep
igniter cable dry.
5. Tighten nut holding piezo
igniter to heater cabinet. Nut
is located inside heater
cabinet at top.
6. Replace igniter cable
7. Replace piezo igniter
SOLUTION
1. Turn on gas supply or open
manual shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while in
PILOT position.
Page 42
Page 38
OBSERVED
PROBLEM
ODS/PILOT lights but flame
goes out when control knob is
released
4. Air in gas lines when
installed
5. Depleted gas supply
6. ODS/Pilot is clogged
7. Gas regulator setting is not
correct
POSSIBLE
PROBLEM
1. Control knob is not fully
pressed in
2. Control knob not pressed in
long enough
3. Safety interlock system has
been triggered (if equipped)
4. Manual shutoff valve not
fully open
5. Thermocouple connection
loose at control valve.
6. Pilot flame not touching
thermocouple, which allows
thermocouple to cool,
causing pilot flame to go
out. This problem can be
caused by one or both of the
following:
A) low gas pressure
B) dirty or partially
clogged ODS/Pilot
7. Control valve damaged
4. Continue to hold down control
knob. Repeat igniting
operation until air is removed.
5. Contact local propane gas
company
6. Clean ODS/Pilot or replace
ODS/Pilot assembly
7. Replace gas regulator
SOLUTION
1. Press control knob completely
2. After ODS/Pilot lights keep
control knob pressed 30
seconds
3. Wait 1 minute for safety
interlock system to reset
4. Fully open manual shutoff
valve
5. Hand tighten until snug, then
tighten 1/4 turn
6. A) contact local propane gas
company
B) Clean ODS/Pilot (See
Cleaning and Maintenance),
or replace ODS/Pilot
assembly
7. Replace valve control
Page 43
OBSERVED
Page 39
PROBLEM
Burner does not light after ODS/
Pilot is lit
Delayed ignition of burner
Burner backfiring during
combustion
Slight smoke or odor during
initial operation
Heater produces a whistling
noise when burner is lit
POSSIBLE
CAUSE
1. Burner orifice is clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Burner orifice is clogged or
damaged
2. Burner damaged
3. Gas regulator defective
1. Residues from manufacturing
process
1. Turning control knob to HI
position when burner is cold
(if equipped with this type of
valve)
2. Air in gas line
3. Air passageways on heater
blocked
4. Dirty or partially clogged
burner orifice
SOLUTION
1. Clean burner (see Cleaning
and Maintenance) or replace
burner orifice
2. Contact local propane gas
company
1. Contact local propane gas
company.
2. Clean burner (see Cleaning
and Maintenance) or replace
burner orifice
1. Clean burner (see Cleaning
and Maintenance) or replace
burner orifice
2. Replace burner
3. Replace gas regulator
1. Problem will stop after a few
hours of operation
1. Turn control knob to LOW
position and allow to warm
2. Operate burner until air is
removed from line. Call
local propane company to
check gas line.
3. Observe minimum
installation clearances
4. Clean burner or replace
orifice
Page 44
Page 40
IF YOU SMELL GAS:
* DO NOT TRY TO LIGHT APPLIANCE
* DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY
PHONE IN YOUR BUILDING
* IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S
PHONE. FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.
* IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
IMPORTANT: Operating heater where impurities in the air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc. create
fumes. These fumes may mix with combustion air and create odors.
WARNING
OBSERVED
PROBLEM
Heater produces a clinking/
ticking noise just after burner is lit
or shut off
Heater produces unwanted odors
Heater shuts off in use
(ODS operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
POSSIBLE
CAUSE
1. Metal expands while heating
or contracts while cooling
1. Heater burning vapors from
paint, hairspray, glues, etc.
(See Important above)
2. Low fuel supply
3. Gas leak (See WARNING
above)
1. Not enough fresh air is
available.
2. Low line pressure
3. ODS/Pilot is partially clogged
1. Gas leak (See WARNING,
above).
2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak (See WARNING,
above).
SOLUTION
1. This is common with most
heaters. If noise is excessive,
contact a qualified service
person.
1. Ventilate room. Stop using
odor causing products while
heater is running.
2. Refill supply tank.
3. Locate and control all leaks.
See Checking Gas
Connections.
1. Open window/door for
ventilation
2. Contact local propane co.
3. Clean ODS/Pilot
1. Locate and correct all leaks
(see Checking Gas
Connections)
2. Replace control valve
1. Remove foreign matter from
gas tubing
2. Locate and correct all leaks
(see Checking Gas
Connections).
Page 45
SERVICING
Page 41
Repair and replacement work should only be performed by a qualified service technician.
Always shut off the gas supply and make sure heater is cool before beginning any service
operation. Check for gas leaks after servicing.
REPAIR PARTS
A parts list with exploded view follows. Always include correct name, part number, and model
number of the heater when ordering service parts. Please contact your local dealer or distributor
when ordering . If one is not available, you may contact.
New Buck Corporation
8000 Highway 226 South
Spruce Pine, NC 28777
Page 46
REPLACEMENT PARTS
Page 42
ITT VALVE
(Picture on page 43)
KEY# PART DESCRIPTION PART NUMBER
1. Carling Switch PE RA911VB
2. Female Terminals PE 5X425
3. Piezo Striker PE 124461
4. Piezo 14" Igniter Wire PE UL3573
5. Pilot (NAT.) Copreci PE 2150053 - NAT.
5. Pilot (LP) Copreci PE 2150054 - LP
6. Pilot Tube 1/4" MF 147AL
7. 1/8" x 1/4" Compression Adapter PH 6842
8. Regulator (LP) Maxitrol PE RV12LF90
8. Regulator (NAT.) Maxitrol PE RV12LF30
9. 3/8" Supply Tube PO 38812ALMTUB
10. 3/8" x 3/8" Elbow (Brass) PH 4966
11. Generator ITT PE G251F245
12. Jumper Wire 6" PE 65 JUMPER
13. 3/8" IPT Male & Female Connector PH 4866
14. 1/2" x 12" Gas Connector PO 20-2131-12
15. Gas Ball Valve PO 110-553
16. Valve (LP) ITT PE B67SA-233
16. Valve (NAT.) ITT PE B67RA-234
17. Burner Tube 3/8" PO 38117ALMTUB
18. Orifice Holder PO 54ORFHLD
19. Orifice PO ORIFICE
20. Burner Tube PO DTBURN
21. Burner Base PSNV 0000
OTHER PARTS (NOT SHOWN)
22. Fan Motor PE SBRO84
23. Power Cord PE 400240
24. Strain Release PE 400320
25. Thermostat PE 400130
26. Male Terminals PE 5X428
27. Jumper Wire 12" PE 12JUMPER
28. Gas Log Set PO C-3329
29. Fan Speed Control Label PE KB9724
30. Rheostat PE 204
31. Rheostat Knob PE 204A
32. Heyco 1-1/4" Grommet PE HEYCO2883
Page 47
21
Page 43
20
19
18
16
17
8
9
THERMO
GEN
ADJ
PILOT
7
6
5
4
11
10
12
3
ITT
GENERAL
CONTROLS
AUX
2
T
E
S
E
R
N
O
O
T
S
T
S
E
O
R
IL
P
P
OFF
ON
13
1
14
15
Page 48
REPLACEMENT PARTS
Page 44
SIT MODULATING VALVE
OR SIT MANUAL VALVE
(Picture on page 45)
KEY# PART DESCRIPTION PART NUMBER
1. Pilot (NAT.) Copreci PE 2150053 - NAT.
1. Pilot (LP) Copreci PE 2150054 - LP
2. Thermopile (Copreci) PE TPT100 / 433
3a. Pilot Tube 1/4" MF 147AL
3b. Pilot Tube 1/4" MF 147AL
4. Burner Tube 3/8" PO 38ALMTUB
5. Pilot Regulator (LP) Maxitrol PE RV 122F90
5. Pilot Regulator (NAT.) Maxitrol PE RV 122F30
6. Burner Tube PO DTBURN
7. Orifice Holder PO 54ORFHLD
8. Orifice PO ORIFICE
9. Valve (LP) SIT (Modulating) PE 0630504
9. Valve (NAT.) SIT (Modulating) PE 0630504
9A. Valve (LP) SIT Manual PE0630.522
9A. Valve (NAT.) SIT Manual PE0630.522
10. Burner Base PSNV0000
11. Valve Regulator (LP) Maxitrol PE RV20LF90
11. Valve Regulator (NAT.) Maxitrol PE RV20LF35
Black Pipe:
12. Brass 90 degree street elbow PH1166
13. 3/8" x 1-1/2" Nipples (1) PO 38112BINIP
14. 3/8" x 5" Nipples (1) PO 385BINIP
15. Brass Pipe Bushing PH11086
16. 1/2" x 12" Gas Connector PO 20-2131-12
17. 3/8" Straight to 3/8" Flare Connector PH 4866
18. 1/8" x 1/4" Compression Adaptor PH 6842
19. Gas Ball Valve PO 110-533
OTHER PARTS (NOT SHOWN)
20. Fan Motor PE SBRO84
21. Power Cord PE 400240
22. Strain Release PE 400320
23. Thermostat PE 400130
24. Male Terminals PE 5X428
25. Jumper Wire 12" PE 12JUMPER
26. Gas Log Set PO C-3329
27. Fan Speed Control Label PE KB9724
28. Rheostat PE 204
29. Rheostat Knob PE 204A
30. Heyco 1-1/4" Grommet PE HEYCO2883
Page 49
Page 45
10
9
8
7
4
L
O
12
Sit
I
F
F
O
PILOT
11
12
13
14
15
6
H
19
17
16
1
2
3B
5
18
3A
Page 50
REPLACEMENT PARTS
Page 46
SIT MILLIVOLT VALVE
Picture on Page 47
KEY# PART DESCRIPTION PART NUMBER
1. 820 MV. S.I.T. VALVE LP-PE 820636
NAT– PE 820637
2. GENERATOR (PILOT ASSEMBLY)
3. BURNER TUBE PO DTBURN
4. O.D.S PILOT (L.P.) O.P. ASSEMBLY PE 8404C
O.D.S PILOT (NAT.) O.P. ASSEMBLY PE 8204C
5. THERMO-COUPLE (PILOT ASSEMBLY)
6. 2"-3/8" BLACKIRON NIPPLE PO 382BINIP
7. BURNER SUPPLY LINE ELBOW PH4966
8. 21" PILOT TUBE 3/16" MF 31621ALMTUB
9. ORIFICE PO ORIFICE
10. ORIFICE HOLDER PO 54ORFHLD
11. 3/8" NUT & SLEEVE PH 616 & PH 606
12. PIEZO STRIKER PE 124461
13. CARLING SWITCH
(AUTO/OFF/MANUAL) PE RC211RB
14. 12" SWITCH WIRES PE 12JUMPER
15. 12" GENERATOR WIRE (PILOT ASSEMBLY)
16. 14 3/4" x 3/8" BURNER SUPPLY TUBE PO 381434ALMTUB
17. 3/8" FIP TO 1/2" MPT PIPE BUSHING PH 11086
18. 1/2" BALL VALVE WITH PRESSURE TAP PO 110-553
19. 1/2" FLARE TO 1/2" STRAIGHT (FLEX LINE ASSEMBLY)
20. 1/2" FLEX LINE PO 20-213-12
21. 1/2" FLARE TO 3/8" FLARE PH 4286
Page 51
15
Page 47
SIT MILLIVOLT
8 16
2
7
4
3
5
10
11
1
6
17
9
18
19
20
21
12
13
14
Page 52
REPLACEMENT PARTS FOR
Page 48
EMBER STOVE BASE (ESB)
(PICTURE ON PAGE 49)
A parts list with exploded view follows. Always include correct name, part number, and model
number of the heater when ordering service parts.
KEY# PART DESCRIPTION PART NUMBER
SIT - MILLIVOLT
1. O.D.S. PILOT (L.P.) O.P. ASSEMBLY PE 8404C
1. O.D.S. PILOT (NAT) O.P. ASSEMBLY PE 8204C
2. GENERATOR ASSEMBLY (Part of Pilot Assembly)
3. PILOT TUBE 3/16" MF 31612 ALMTUB
4. GENERATOR WIRE (Part of Pilot Assembly)
5. REAR BURNER PO VE1002
FRONT BURNER PO 383436
6. INLET ELBOW PH 4966
7. 3/8" COMP. NUT & SLEEVE PH 616 & PH 606
8. 3/8" BURNER SUPPLY TUBE (FLEX)
- 3 pieces 12" PO T6-12
9. 24" SWITCH WIRES PE 30JUMPER
10. CARLING SWITCH
(AUTO/OFF/MANUAL) PE RC211RB
11. PIEZO STRIKER PE 124461
12. PIEZO 18" IGNITOR WIRE PE 8400-014
13. MALE RUN TEE FITTING PH 64A-66
14. THERMO-COUPLE
15. MANIFOLD OUTLET CONNECTOR PH 68A-6C
16. ORIFICES L.P.
FRONT #1.25mm PO 125 MVORF
REAR #.046” PO 046 MVORF
NATURAL
FRONT #2.05mm PO 205 MVORF
REAR #48 PO 48 MVORF
17. 820 mv. S.I.T. VALVE LP - PE 820-636
NAT - PE 820-637
18. 8”L 3/8”BURNER SUPPLY LINE MF382ALMTUB
(3/4”-3/8” FLARE/3/8” COMP. N&S FITTINGS)
* LOG SET EMBER STOVE BASE (CERAMIC)
Page 53
10
Page 49
REPAIR PARTS
A parts list with exploded view follows. Always include correct name,
part number, and model number of the heater when ordering service
parts. Please contact your local dealer or distributor when ordering . If
one is not available, you may contact.
New Buck Corporation
8000 Highway 226 South
Spruce Pine, NC 28777
15
6
11
8
ESB
SIT MILLIVOLT
13
12
8
7
16
16
17
5
6
4
14
1
2
3
Page 54
Page 50
NEW BUCK CORPORATION
We reserve the right to amend these specifications at any time without notice. The only
warranty applicable is our standard written warranty. We offer no other warranty, expressed or
implied.
LIMITED WARRANTY
VENT-FREE GAS LOG HEATER
New Buck warrants this product to be free from defects in materials and components for two
(2) years from the date of first purchase, provided that the product has been properly installed,
operated, and maintained in accordance with all applicable instructions. To make a claim
under this warranty the Bill of Sale or canceled check must be presented.
This warranty is extended only to the original retail purchaser and covers the cost of parts
required to restore the heater to proper condition. Warranty parts MUST be obtained through
an authorized Buck Stove dealer and/or New Buck, who will provide original factory
replacement parts. Failure to use original factory replacement parts voids this warranty. The
heater MUST be installed by a qualified installer in accordance with all local codes and
instructions furnished with the unit.
Warranty does not apply to parts that are not in original condition, normal wear and tear, or
parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance
or defects caused by improper installation.
WARRANTY DOES NOT COVER:
- Removal and re-installation cost
- Labor costs for replacements or repairs
- Transportation
- Cost of service call to diagnose trouble
- Painted surfaces
- Damage or defect caused by improper installation, accident, misuse, abuse, or alteration
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT
GOVERNS THE SALE OF THE PRODUCT, THIS EXPRESS WARRANTY EXCLUDES
ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF
ANY AND ALL WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR FROM THE DATE
OF FIRST PURCHASE. NEW BUCK LIABILITY IS HEREBY LIMITED TO THE
PURCHASE PRICE OF THE PRODUCT AND NEW BUCK SHALL NOT BE LIABLE FOR
ANY OTHER DAMAGES WHATSOEVER INCLUDING INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or
limitation of incidental or consequential damages, so the above limitation on implied
warranties, or exclusion on damages may not apply to you.
This warranty gives you specific legal rights. Other rights may vary from state to state.
Page 55
Page 51