MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A
FREESTANDING FIREPLACE OR WITH AN
OPTIONAL WOODEN SURROUND
ON
VENT-FREE
WA RN I N G: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
− Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the fire department.
− Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to
section “ Producing Adequate Ventilation” page 12.
This appliance may be installed in an aftermarket, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
WARNING
This appliance is equipped for (natural or propane) gas .
Field conversion is not permitted.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Manufacturer: NEW BUCK CORPORATION
P.O. Box 69
8000 Highway 226 South
Spruce Pine, NC 28777
This appliance is intended for supplemental heating.
Revised December 2006
Page 2
Page 3
TABLE OF CONTENTS
Page 1
Safety Information and Warnings ........................................................................................ 3
IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY
BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THE APPLIANCE.
IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM
BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING.
Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or
nausea. If you have these signs, the heater may not be working properly. Get fresh air at once!
Have heater serviced.
Some people-pregnant women, persons with heart or lung disease, anemia, those under the
influence of alcohol, and those at high altitudes-are more affected by carbon monoxide than
others.
CAUTION: Strong drafts, such as a ceiling fan placed directly in front of the heater
(pulling from either direction) may create sooting. Sooting will discolor
walls.
1. The installation must conform with local codes ,or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA54.
2. This appliance may be installed in an After-Market* Manufactured (Mobile) Home,
where not prohibited by state or local codes.
* (After-Market: Completion of sale, not for purpose of resale from the manufacturer.)
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
NOTE: “Producing Adequate Ventilation” page 12.
IMPORTANT:
IS BENEFICIAL, INSTALLING HEATER IN ROOMS WITHOUT ADEQUATE
VENTILATION MAY CAUSE MILDEW TO FORM FROM TOO MUCH MOISTURE.
3. Never install this heater:
♦ in a recreational vehicle, bathroom, bedroom, or any other sleeping quarters
♦ where curtains, furniture, clothing, or other flammable objects are less than 42" from the
front of the heater
♦ in high traffic areas or in windy areas
4. Two models are available. One specific model for propane (LP), and one for natural gas.
Use the correct type gas for your home. Do not convert from one gas type to another.
“WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.”
VENT-FREE HEATERS ADD MOISTURE TO THE AIR. ALTHOUGH THIS
Page 6
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure.
Page 4
6. What To Do IF You Smell Gas:
Shut off gas supply.
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
7. When operated for the first time, the logs may emit a “paper burning” smell. This smell will
gradually diminish and will be totally eliminated after the first few hours of operation. Run the gas
logs with the flue damper open during this time. Do not use blower at this time.
8. “This heater shall not be installed in a confined space or unusually tight construction unless
provisions are provided for adequate combustion and ventilation air.” See “Producing
Adequate Ventilation”, page 12.
9. Surface of gas logs becomes very hot when operating. Keep children and adults away from hot
surface. Gas logs will remain hot for sometime after shutdown. Allow surface to cool before
touching.
10. Do not place clothing or other flammable material on or near the appliance.
11. If equipped, fresh air damper must be closed.
12. Keep appliance area clean and free from combustible materials, gasoline, and other flammable flammable vapors and liquids. .
13. If burner shuts off, do not relight until you provide fresh outside air. If burner continues to shut off,
have unit serviced.
14. Do not use this heater if any part has been under water. Immediately call qualified service
technician to inspect the room heater and to replace any part of the control system and any
gas control which has been under water.
15. Turn off the heater and let cool before servicing.
16. These logs are made of bonded fiber. When removing logs and base, do not damage the bonded
material. If the material is damaged extensively, loose fiber dust could be emitted into the air.
17. Any safety screen or guard removed for servicing an appliance must be replaced prior to
operating the heater.
18. This appliance is intended for supplemental heating.
19.
“WARNING: Any change to this heater or its controls can be dangerous.”
20. Installation and repairs should be performed by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
It is imperative that control compartments, burners and circulating air passageways of the
appliance be kept clean.
Page 7
21. All heater screens must be kept clean when operating the gas logs.
Page 5
”WARNING: Failure to keep the primary air opening (s) of the burner (s) clean may result
22. .
in sooting and property damage.”
23. Do not use this heater for burning trash or cooking. Never place matches, paper, garbage, or any
other material on top of logs or into the flames.
24. Do not install or operate this heater in areas where impurities in the air exist (such as tobacco
smoke or heavy cooking grease). Particles from impurities may discolor walls.
25. Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies.
26. Children and adults should be alerted to the hazards of high surface temperature and should
stay away to avoid burns or clothing ignition.
27. Young children should be carefully supervised when they are in the same room with the
appliance.
28. An unvented room heater having an input rating of more than 10,000 Btu per hour shall not
be installed in a bedroom or bathroom.
29. The appliance and its appliance main gas valve must be disconnected from the gas supply
pipping system during any pressure testing of that system at test pressure in excess of 1/2
psi (3.5 kPa).
30. The appliance must be isolated from the gas supply pipping system by closing its equipment
shut-off valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
31. “
WARNING: Do not allow fans to blow directly into fireplace. Avoid any drafts that alter
burner flame patterns.”
32. “
WARNING: Do not use a blower insert, heat exchanger insert or other accessory not
approved for use with this heater.”
33. Adequate clearances around air openings. Nothing may be placed over any of the air openings on
this appliance, or can any of the air openings be modified in anyway.
34. “Trim panels or surrounds shall not seal ventilation openings in the fireplace.”
35. “A fireplace screen must be in place when the appliance is operating and, unless other
provisions for combustion air are provided, the screen shall have opening(s) for introduction
of combustion air.
Page 8
MASONRY INSERT INSTALLATION/ SOLID
Page 6
FUEL BURNING FIREPLACE MODEL 32 (FP)
1. The Model 32 (FP) may be installed in a masonry fireplace.
“WARNING: Before installing in a
solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of
soot, creosote, ashes and loose paint by
a qualified chimney cleaner.”
NOTE: Any outside air ducts and / or
ash dumps in the fireplace shall be permanently closed at time of appliance
installation.
WALL
LEFT SIDE
7"
5”
13"
42”
24"
20"
16”
RIGHT SIDE
21-1/2"
FRONT
24” TO COMBUSTIBLES
25-1/2"
Figure 1
12"
“WARNING: Any glass doors shall be
fully opened when appliance is in operation.”
Your new Buck Vent-Free gas heater may be installed in a Residential or *After-Market Mobile
Home, where prohibited by state or local codes.
*After-Market: Completion of sale. Not for purpose of resale from the manufacturer.
This appliance is for use with the type of gas indicated on the rating plate. Not convertible
for use with other gases.
2. Minimum dimensions sidewall and mantel:
Sidewall-not less than 5" See Figure 1.
Mantel-not less than 16" See Figure 1.
3. Center Model 32 in masonry fireplace. Position front of heater even with front of fireplace
chamber if possible.
4. Place side trim panels flat against the fireplace. Draw a vertical reference line along the
inside edge of the trim panel.
5. Place top trim panel on top of unit. Draw reference line for mounting on lower edge of pane
NOTE: The installer of this appliance must mechanically (peel and stick) attach the marking
supplied with this unvented appliance before installing to the inside of the firebox of the solidfuel burning fireplace or listed ventless firebox enclosure into which the unvented fireplace insert is installed. See the example of the marking on page 18 of this manual.
CAUTION: Cutting any sheet-metal parts of the solid-fuel burning fireplace or listed ventless
enclosure in which the unvented fireplace is to be installed is prohibited.
NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5
inch (37.5) diameter or less may be drilled through the lower sides or bottom of the firebox in a
proper workmanlike manner. This access hole must be plugged with non-combustible insulation
after the gas supply line has been installed.”
“Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applicable) can
be removed from the fireplace before installing the unvented fireplace insert.”
“Smoke shelves shields and baffles may be removed if attached by mechanical fasteners.”
Page 9
6. Slide the unit out and install the trim panels with a drill or screw gun. (Self tapping screws
Page 7
provided).
NOTE: Make sure the gas supply line is hooked up at this time, and check for leaks at the
connection using soap and water.
CAUTION: Do Not use an open flame to check for leaks.
7. Place logs on the burner base as shown on page 16.
8. For gas hookup and pressure tap test, see instructions on pages 17 & 18.
NOTE: When operated for the first time, the logs and paint may emit a “paper burning smell”.
This smell will gradually diminish after a few hours of operation. Run the heater with the flue
damper, windows or doors, open during this time. DO NOT use blower at this time.
Page 10
FREESTANDING INSTALLATION
Page 8
MODEL 32 (FS)
1. Determine the exact location of your gas heater.
NOTE: Due to high temperatures, this heater should be located out of traffic areas and away
from furniture and draperies.
NOTE: For safe installation the minimum clearances must be met. See Figure 2. For floor
protector, see last paragraph, page 8.
NOTE: Clearance form
top of appliance to ceiling is 42”. (Not shown
in figure 2)
WALL
NOTE:
DIMENSIONS SHOWN ARE
MINIMUM CLEARANCE TO
COMBUSTIBLE WALL.
5"
4"
WALL
4"
4"
VE
STOVE
Figure 2
CAUTION: THE INSTALLATION MUST CONFORM TO LOCAL CODES. IN THE
ABSENCE OF LOCAL CODES, INSTALLATION MUST CONFORM WITH THE NATIONAL
FUEL GAS CODE,ANSI Z223.1/NFPA54.
NOTE: See page 17 for “Gas Connection” and page 18 for “Pressure Check”.
2. Check gas type. Use only the type of gas indicated on the valve rating plate. If the type of gas listed
on the plate is not your type of gas supply, DO NOT INSTALL.
model. Position logs as shown on page 16. Position screen before leaving heater unattended.
Contact your dealer for proper
WARNING: YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY
ARE IN THE SAME ROOM AS THE HEATER. DO NOT PLACE CLOTHING OR OTHER
FLAMMABLE MATERIAL ON OR NEAR THE HEATER.
NOTE: When the appliance is installed directly on carpeting, tile or other combustible material, other
than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width
and depth of the appliance.
Optional Pedestal (Part#FAP11) Instructions: Lay the heater on its back (use a drop-cloth to protect
the back of the heater and the surface of your flooring). Place pedestal against the bottom of the heater.
Center pedestal from left to right and from front to rear. Mark the holes on the angle of the top of the
STO
pedestal onto the bottom of the heater. Lay the pedestal aside.
Drill the marks made onto the heater with a 1/8” bite (not provided). Replace the pedestal and secure with the screws provided. Next stand the heater to the upright position. Place the
heater in the desired location following the clearances above in
figure 2. Note: At this point you may need
to secure the pedestal to the floor with screws or an “ell” bracket (not provided)
for safety concerns. Next hook up the gas supply line following the instructions in this manual completely.
Page 11
ALCOVE INSTALLATION
Page 9
CAUTION:
1. For clearances, see Figure 3. The minimum clearances must be met.
2. For “Installation and Gas Connection”, see page 17.
READ ENTIRE MANUAL BEFORE INSTALLING HEATER.
FOR YOUR SAFETY:
WHAT TO DO IF YOU SMELL GAS
-Do not try to light appliance.
-Do not touch any electrical switch.
-Do not use telephone in building.
-Call your gas supplier immediately, from a neighbor’s phone. Follow the gas supplier
instructions.
-If you cannot reach your gas supplier, call the Fire Department.
-Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of
this appliance or any other appliance.
WARNING: DO NOT USE THIS ROOM HEATER IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE ROOM HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM
AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
SERVICE, OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST BE PERFORMED
BY A QULIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
“WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.”
NOTE: The depth of the alcove must allow a 4" minimum clearance at the rear. The width of
the alcove must allow a 5” clearance on the right side and the left side. The height of the alcove
must allow for a 10” clearance form the top of the heater to the ceiling of the alcove. The front
edge of the heater must meet the front of the alcove, and have a minimum of 24” to any
combustible material.
WALL
NOTE:
DIMENSIONS SHOWN ARE
MINIMUM CLEARANCE TO
COMBUSTIBLE WALL.
5"
STOVE
FLOOR
PROTECTOR
10"
4"
Figure 3
Page 12
INSTALLATION OF MODEL 32 (WS)
Page 10
A. Determine the desired location for your heater and wooden surround. See “Freestanding
B To install metal filler strips to the surround (after completing step 2 of surround assembly),
C Make sure wooden mantel is in correct position. Place the heater into the surround. Connect gas line
D Make sure you leave 1/4" space between the metal filler strip and the top and sides of the heater.
NOTE: You will need to heave 1/2" space between the back of the wooden mantel and an adjacent
combustible wall.
NOTE: If a masonry hearth is built up under front bottom of heater, and you do not use the hearth
provided with the wooden surround, you must have 12" of non-combustible material from front bottom
edge of heater.
WITH OPTIONAL WOODEN SURROUND(KIT#PA-KDM32)
Installation” for minimum clearances.
position the wooden mantel over the unit, centering it up in the cabinet. Place the metal filler strips
to the side of the cabinet, allowing 1/4" air space between the strips and side of the cabinet. Make a
light pencil mark on strip. Remove the wooden mantel from around cabinet. Align the pencil mark
with the inner edge of the cabinet from back side. Using the screws provided with heater, fasten
strips to the back of the mantel.(At this point complete steps 3 and 4 of surround assembly)
to the heater, following all the instruction in this manual completely
You will also want to position the heater so you have 5 1/2" from outer lip of hot air vent to the
pieces of metal strips, not the wooden face of the mantel. See Figure 4.
5-1/2"
METAL STRIP
ON
Figure 4
(WS) ASSEMBLY INSTRUCTIONS
Tools Needed: Medium Phillips Screwdriver
Step 1: Lay out all components. (See diagram 1)
Step 2: Assemble end panels (A & B) to top front rail ( C ).(See section “B” above on this page)
Step 3: Stand end panels and top front rail onto hearth and fasten down with screws provided (See diagram 1).
NOTE: Position back of end panels with back of hearth centering assembly from each end. Install front
screws first, then pull back towards the inside to square the surround (mantel) up. Install screws through
back holes.
Step 4: Place top onto surround, flush with back and equal on each end. Secure both ends and middle
with screws provided.
CONTINUED ON PAGE 11
Page 13
EXPLODED VIEW OF MODEL 32 (WS)
Page 11
WOODEN SURROUND BASE (HEARTH)
(SHOWN AS VIEWED FROM REAR OF SURROUND)
INSTALLATION IN RESIDENTIAL
OR AFTER-MARKET MOBILE HOMES
A QUALIFIED SERVICE TECHNICIAN MUST INSTALL THIS HEATER.
CHECK FOR STATE AND LOCAL CODES CONCERNING INSTALLATION
CHECK GAS TYPE:
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE
RATING PLATE. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER
GASES.
INSTALLATION SUPPLIES:
Before installing the heater, gather the following materials:
- external regulator - ground joint union
(supplied by installer for propane) - sediment trap
- piping (check local codes) - tee joint
- manual shutoff valve* - pipe wrench
- test gauge connection* - sealant (resistant to LP gas)
* An C.S.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test
gauge connection. Purchase the optional C.S.A. design-certified manual shutoff valve from your dealer.
MAINTAIN THE MINIMUM CLEARANCES SHOWN THROUGHOUT THIS MANUAL. IF
POSSIBLE, PROVIDE GREATER CLEARANCES FROM FLOOR, CEILING, AND
ADJOINING WALL.
NOTE: See “Producing Adequate Ventilation” page 12.
.THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET*, PERMANENTLY
LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY LOCAL
CODES.
*After Market: Completion of sale, not for the purpose of resale from the manufacturer.
REQUIREMENTS.
NOTICE:
WARNING
Page 14
PRODUCING ADEQUATE
Page 12
VENTILATION
This section is for residential or manufactured (mobile) installation
“This heater shall not be installed in a confined space or unusually tight construction unless provisions are adequate combustion and ventilation air.”
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space
whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8m 3 per kw) of the
aggregate input rating of all appliances installed in that space and an unconfined space as a
space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8m
the aggregate input rating of all appliances installed in that space. Rooms communicating
directly with the space in which the appliances are installed, through openings not furnished
with doors, are considered a part of the unconfined space.
“WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS
SMALLER THAN THAT DEFINED AS AN UNCONFINED SPACE OR IF THE
BUILDING IS OF UNUSUALLY TIGHT CONSTRUCTION, PROVIDE ADEQUATE
COMBUSTION AND VENTILATION AIR BY ONE OF THE METHODS DESCRIBED
IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, SECTION 5.3 OR
APPLICABLE LOCAL CODES.”
Unusually tight construction is defined as construction where:
a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder
with a rating of 1 perm (6 x 10
b) Weather stripping has been added on openable windows and doors, and
c) Caulking or sealants are applied to areas such as joints around window and door frames,
between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations
for plumbing, electrical, and gas lines, and at other openings.
-11
kg per pa-sec-m2) or less with openings gasketed or sealed;
3
per kw) of
NOTE: SOME AREAS IN THE UNITED STATES HAVE HIGHER REQUIREMENTS
FOR CUBIC FEET PER 1000 BTU/ HOUR INPUT. (EX. CINCINNATI, OHIO CODES
REQUIRE 70 CUBIC FEET). CHECK YOUR LOCAL CODE BEFORE
INSTALLATION.
DETERMINING FRESH-AIR FLOW FOR
HEATER LOCATION
DETERMINE IF YOU HAVE A CONFINED OR UNCONFINED SPACE
Use this worksheet to determine if you have confined or unconfined space.
SPACE: Includes the room in which you will install heater plus adjoining rooms with
doorless passageways or ventilation grills between the rooms.
Page 15
Page 13
1. Determine the volume of the space (length x width x height).
Length x Width x Height =_________cu.ft.(volume of space)
EXAMPLE: 20 ft.(Length) x 16 ft.(Width) x 8 ft.(ceiling Height)=
2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the
volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum BTU/Hr the
space can support.
_________(volume of space)/50 cu. ft. =maximum BTU/Hr the space can support)
EXAMPLE: 2560 cu. ft. (volume of space /50 cu. Ft .= 51.2 or
51200 (maximum BTU/Hr the space can support)
3. Add the BTU/Hr of all fuel burning appliances in the space.
Vent-free heater _______________BTU/Hr
Gas water heater* _______________BTU/Hr
Gas furnace _______________BTU/Hr
Vented gas heater _______________BTU/Hr
Gas fireplace logs _______________BTU/Hr
Other gas appliances* + _______________BTU/Hr
Total = _______________BTU/Hr
Example: Gas water heater 40000 BTU/Hr
Vent-free heater + 18000 B
TU/Hr
Total = 58000 BTU/Hr
*Does not include direct-vent gas appliances. Direct-vent draws combustion air
from the outdoors and vents to the outdoors.
4. Compare the maximum BTU/Hr the space can support with the actual amount of BTU/
Hr used.
____________BTU/Hr (maximum the space can support)
____________BTU/Hr (actual amount of BTU/Hr used)
Example: 51200 BTU/Hr (maximum the space can support)
58000 BTU/Hr (actual amount of BTU/Hr used)
The space in the above example is a confined space because the actual BTU/Hr used is more
than the maximum BTU/Hr the space can support. You must provide additional fresh
air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining
room. If the extra space provides an unconfined space, remove door to adjoining room or add
ventilation grills between rooms. See “Ventilation Air From Inside Building”, page 21.
B. Vent room directly to the outdoors. See “Ventilation Air From Outdoors”, page 22.
C. Install a lower BTU/Hr heater, if lower BTU/Hr size makes room unconfined.
If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the
space is an unconfined space. You will need no additional fresh air ventilation.
WAR N I NG : YOU MUST PROVIDE ADDITIONAL VENTILATION AIR IN A
CONFINED SPACE
Page 16
VENTILATION AIR
Page 14
VENTILATION AIR FROM INSIDE BUILDING
This fresh air would come from an adjoining unconfined space. When venting to an adjoining
space, you must provide two permanent openings: one within 12" of the ceiling and one within
12" of the floor on the wall connecting the two spaces. (See Options 1 and 2, Figure 5). You
can also remove door into adjoining room. (See Option 3, Figure 5).
WARNING
REWORK WORKSHEET, ADDING THE SPACE OF THE ADJOINING
UNCONFINED SPACE. THE COMBINED SPACES MUST HAVE ENOUGH FRESH
AIR TO SUPPLY ALL APPLIANCES IN BOTH SPACES.
NOTE: Each opening shall have a minimum free area of 1 square inch per 1000 BTU’s per
hour of the total input ratings of all gas utilization equipment in the confined space, but not less
than 100 square inches.
Figure 5: Ventilation Air From Inside Building
NOTE: Drill holes on bottom of pedestal base on each corner. Unit must be fastened to floor
with screws.
Page 17
WARNING
Page 15
THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF
NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE
FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR
THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME.
VENTILATION AIR FROM OUTDOORS
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent
openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items
directly to the outdoors. These spaces include attics and crawl spaces. Follow the National
Fuel Gas Code NFPA 54/ANSI Z223.1, Section 4.3, “Air For Combustion and Ventilation” for
required size of ventilation grills or ducts. See Figure 6.
IMPORTANT: Do not provide openings for inlet air into attic if attic has a thermostatcontrolled power vent. Heated air entering the attic will activate the power unit.
Figure 6: Ventilation Air From Outdoors
Page 18
PREPARING LOG KIT
Page 16
Open the cartons containing the Burner Base and the M-3019 logs. The logs are numbered
as follows: (1) Front, (2) Rear, (3) Right side top, (4) Left side top.
WAR N I NG : POSITIONING OF LOGS IS VERY CRITICAL (SEE FIGURE 7).
(1) POSITION REAR LOG (#2) , IN REAR LOG HOLDERS, CENTERING LEFT TO
RIGHT.
(2) PLACE FRONT LOG (#1) OVER FRONT PART OF BURNER TUBE. LOCATE LOG
IN THE CENTER OF THE BURNER BASE. MAKE SURE THE MIDDLE SUPPORT
LEG OF THE FRONT LOG IS IN THE HOLDERS LOCATED IN THE CENTER OF
THE BURNER BASE, JUST BEHIND THE FRONT PART OF THE BURNER TUBE.
(3) TAKE RIGHT TOP LOG (#3) AND PLACE IT IN THE SLOTS LOCATED AT THE
RIGHT SIDE OF THE FRONT AND REAR LOGS, FACING THE BURNER BASE.
(4) PLACE LEFT TOP LOG (#4) IN THE SLOTS OF THE LEFT FRONT AND REAR
LOGS.
(5) WHEN IGNITING THE BURNER, CHECK AND MAKE SURE THE FLAME IS NOT
TOUCHING EITHER SIDE OF LOG (#3), OR LOG (#4). IF FLAME IS TOUCHING
LOGS ON EITHER SIDE, MOVE SLIGHTLY TO THE LEFT OR RIGHT TO
ELIMINATE THE FLAME FROM TOUCHING EITHER LOG.
TOP LEFT
REAR LOG
TOP RIGHT
FRONT LOG
Figure 7
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only
parts specifically approved with this heater may result in property damage or personal injury.
Page 19
GAS CONNECTION
Page 17
Check gas type. Use only the type of gas indicated on the valve rating plate. If the gas type
listed on the plate is not your type of gas supply, DO NOT INSTALL.
proper model.
Contact your dealer for
Always use an external regulator for all LP heaters to reduce the supply tank pressure to a
maximum of 14" W.C. This is in addition to the regulator furnished with the heater.
WARNING:CONNECTION DIRECTLY TO AN UNREGULATED LP TANK CAN
CAUSE AN EXPLOSION.
The normal gas connection is 3/8" N.P.T. made at the left side (facing the front of the
appliance) of the appliance. If a right side connection is desired, the connecting pipe may be
led under the rear of the burner base to terminate at the right hand side for connection at the
inlet of the valve.
NOTE: The connecting pipe must be internally tinned copper tubing for use with natural gas. Test for
leaks using a solution of soap and water after completing the connection. DO NOT USE OPEN
FLAME.
WAR N I NG : ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.
NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch
(37.5mm) diameter or less may be drilled through the lower sides or bottom of the fire box in a proper
workmanlike manner. This access hole must be plugged with non-combustible insulation after the gas
supply line has been installed.”
WARNING: Installation and repairs should be performed by a qualified service person. The
appliance should be inspected before use and at least annually by a professional service person.
More frequent cleaning may be required due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments, burners and circulating air passageways of the
appliance be kept clean.
Page 20
GAS PRESSURE CHECK
Page 18
Check the inlet pressure to the burner to ensure that it is shown in the table below.
NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT
Millivolt, and the left side for SIT Modulating.
The appliance and its appliance main gas valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2
psi (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shut
-off valve during any pressure testing of the gas supply piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
Maximum Heat Input 33,000 33,000 33,000 33,000
Minimum Heat Input 23,000 23,000 12,000 13,000
Gas Inlet Pressure
Maximum 10.5ins.W.C. 13ins.W.C. 10.5ins.W.C. 9.0ins.W.C.
Minimum * 5.0ins.W.C. *11ins.W.C. *5.0ins.W.C. *11ins.W.C.
Manifold Pressure
Maximum 3.5ins.W.C. 9.0ins.W.C. 3.5ins.W.C. 9.0ins.W.C.
Minimum 3.0ins.W.C. 8.2ins.W.C. 2.8ins.W.C. 7.2ins.W.C.
NOTE: On initial installation it may be necessary to bleed out air in the gas lines. Do this by
holding the control knob and turning the knob to the “PILOT” position for about 30 seconds.
To check the regulator pressure, remove the pressure tag plug at the left side of the regulator
facing the heater. The pressure should be checked with the heater burning and the control set
on high. After measuring the pressure, replace the pressure tap plug, ensuring that there are no
leaks.
* For the purpose of minimum input adjustment.
This appliance is equipped for (natural or propane) gas.
Field conversion is not permitted.
Solid fuels shall not be burned in the same fireplace where an unvented room heater has
been installed.
NOTE: The following label has been provided with this appliance and must be read and
then attached to the floor of the fireplace or firebox area beneath the appliance.
The label is a peel and stick label. Make sure the area is cleaned before attaching
the label to it.
“WARNING: This solid-fuel burning fireplace or listed ventless enclosure has been
converted for use with an unvented fireplace insert only. A solid-fuel burning
fireplace cannot be used for burning wood or solid fuels unless all original parts
have been replaced, and the fireplace re-approved by the authority having
jurisdiction. A ventless firebox enclosure cannot be used with an unvented gas log
unless all original parts have been replaced, and the ventless firebox enclosure reapproved by the authority having jurisdiction.”
WA RN I N G
Page 21
LIGHTING INSTRUCTIONS
Page 19
MILLIVO LT VALV E (ITT)
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY,
OR LOSS OF LIFE.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell around the appliance for gas. Be sure to smell next to the
floor because gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
♦ Do not try to light any appliance.
♦ Do not touch any electrical switch; do not use any phone in your building.
♦ Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
♦ If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob
will not push in or turn by hand, don’t try to repair it, call a qualified service technician.
Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system and
any gas control which has been under water.
Page 22
LIGHTING INSTRUCTIONS
Page 20
1. STOP! Read the safety information on previous page.
2. Make sure the manual shutoff valve is fully closed. If equipped with thermostat set to the lowest
setting.
3. Turn off all electrical power to the appliance.
4. Open access panel door located at bottom front of the appliance.
5. Turn control knob clockwise to the full “OFF” position.
ROCKER SWITCH
OFF
ON
PIEZO
IGNITOR ELECTRODE
THERMOGENERATOR
THERMOPILE
BURNER
PILOT
PILOT ASS'Y
PILOT BURNER
CONTROL KNOB
ITT VALVE
PILOT
ADJ
T
O
L
I
P
OFF
P
TO
RE
S
S
O
N
T
E
S
E
R
THERMO GEN
AUX
CONTROLS
ITT
GENERAL
BEFORE INSTALLING THERMOSTAT
REMOVE METAL CONNECTOR
9080706050
THERMOSTAT
FIGURE: 8
When hooking up a Wall Thermostat to valve, remove the Jumper Bar. Do not remove the existing
wires, simply add the wire from the Wall Thermostat to screws (one wire to each screw).
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety informationon the previous page.If you don’t smell
gas, go to the next step.
7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of the
appliance. Fully open the manual shutoff valve.
8. Push the ON/OFF toggle switch to “OFF” (rocker switch).
9. Turn gas control knob counterclockwise to the “PILOT” position.Press in gas control
knob for fifteen (15) seconds.
10. With control knob pressed in , push down (in) and release the ignitor button (ignitor button is
located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep
repeating this step until pilot lights.
11. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute, release the
gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 1
through 9.
• If the knob does not pop up when released, stop and immediately call your service technician or
gas supplier.
Page 23
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF”
Page 21
and call your service technician or gas supplier.
IGNITOR ELECTRODE
THERMO-COUPLE
THERMO-PILE
12. Turn control knob counterclockwise to the “ON” position. Push the “ON/OFF”
toggle switch to the “ON” position. The main burner should light.
13. Close access panel door.
14. Turn on all electrical power to the appliance.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall
Thermostat needs to be set at a higher temperature than the room temperature.
TO TURN OFF GAS TO
PILOT BURNER
APPLIANCE
SHUTTING OFF UNIT
1. Open access panel door located at bottom front of the appliance.
2. “If equip with thermostat set to lowest setting.”
3. Turn control knob clockwise to the “OFF” position.
4. Turn off all electric power to the appliance if service is to be performed.
5. Close access panel door.
SHUTTING OFF BURNER ONLY (Pilot stays lit.)
Turn control knob clockwise to the “PILOT” position.
CAUTION
DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL
SHUTOFF VALVE.
Page 24
THERMOSTAT CONTROL OPERATION
Page 22
• This valve operates off of millivolts produced by the generator. You may choose to use an
optional Wall Thermostat or Remote control. If so, see Figure 2, page 11 for wiring diagram.
MANUAL LIGHTING PROCEDURE
1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match
and a lighter rod.
2. Open access panel door located at bottom front of the appliance.
3. Place the match in the holder and light. With the left hand, turn the control knob
counterclockwise to “PILOT”position. Press in gas control knob for fifteen (15)
seconds.
4. Use rod to light match and ignite pilot. The pilot is located in front of the rear log and burner
on the right hand side of the appliance.
5. Continue to hold the control knob for an additional one (1) minute to ensure the pilot is lit.
6. Turn control knob counterclockwise to the “ON” position. Push the “ON/
OFF” toggle switch to the “ON” position. The main burner should light.
7. Close access panel door.
8. Turn on all electrical power to the appliance.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall Thermostat needs
to be set at a higher temperature than the room temperature.
Page 25
LIGHTING INSTRUCTION
Page 23
MODULATING VALVE (SIT)
OR MANUAL VALVE (SIT)
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.”
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to
the floor because gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup-
plier’s instructions.
• If you cannot reach your gas supplier, call the fire department.”
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob
will not push in or turn by hand, don’t try to repair it’ call a qualified service technician.
Force or attempted repair may result in a fire or explosion.”
D. Do not use this appliance if any part has been under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to replace any part of the control system and
any gas control which has been under water.”
Page 26
LIGHTING INSTRUCTION
Page 24
1. STOP! Read the safety information on preceding page 19.
2. Make sure manual shutoff valve is fully closed.
3. Turn off all electrical power to the appliance.
4. Open access panel door located at bottom front of the appliance.
5. Turn control knob clockwise to the full “OFF” position.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” on preceding page in the Safety Information. If you
don’t smell gas, go to the next step.
7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of
the appliance. Fully open the manual shutoff valve.
8. Press in and turn gas control knob counterclockwise to the “PILOT” position continue pressing in control knob for fifteen (15) seconds.
9. With control knob pressed in, push down (in) and release the ignitor button (ignitor button
is located on the left hand side of the gas control valve) . This will light pilot. If needed,
keep repeating this step until pilot lights.
10. Keep control knob pressed in for one (1) minute after lighting pilot. After one (1) minute,
release control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat
steps 1 through 9.
• If the knob does not pop up when released, stop and immediately call your service techni-
cian or gas supplier.
• “If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call
your services technician or gas supplier.”
Page 27
Page 25
11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the
gas control knob counterclockwise to your desired setting.
12. Close access panel door.
13. Turn on all electrical power to the appliance.
CAUTION
DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF
VALVE.
TO TURN OFF GAS TO APPLIANCE
SHUTTING OFF UNIT
1. Open access cover door.
2. Turn gas control knob clockwise to the full “OFF” position.
3. Turn off all electric power to the appliance if service is to be performed
4. Close access cover door.
SHUTTING OFF BURNER ONLY (pilot stays lit)
Turn control knob clockwise to the “PILOT” position.
CAUTION: Hot while in operation. Do Not Touch. Keep children, clothing, furniture,
gasoline, and other liquids having flammable vapors away.
CAUTION: DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE
MANUAL SHUTOFF VALVE.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury, or loss of life. Refer to owner’s information manual
provided with this appliance. Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
IMPORTANT: Always operate the appliance at the completely “ON” or the completely
“OFF” positions. Never use the heater at a setting between these positions as this can result in
improper combustion and excessive carbon monoxide emissions.
Page 28
THERMOSTAT CONTROL OPERATION
Page 26
1. The thermostat control on this heater differs from standard thermostats. Standard
thermostats simply turn the burner on and off. The thermostat used on this heater
senses the room temperature and adjusts the amount of gas flow to the burner. This
will increase or decrease the flame height. At times, the room may exceed the set
temperature, which will cause the burner to shut off. When room temperature drops
below the thermostat setting, the burner will cycle itself on again. The control knob can
be set to any level between “LO” and “HI”.
NOTE: The thermostat sensing bulb measures the temperature of air near the
heater cabinet. This may not always agree with room temperature (depending on
housing construction, installation location, room size, open air temperatures,
etc.). Frequent use of your heater will allow you to determine your personal
comfort levels.
MANUAL LIGHTING PROCEDURE
1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper
match and a lighter rod.
2. Open access panel door located at bottom front of the appliance.
3. Place the match in the holder and light. With the left hand, turn the control knob
counterclockwise to “PILOT”position. Press in gas control knob for fifteen
(15) seconds.
4. Use rod to light match and ignite pilot. The pilot is located in front of the rear log and
burner on the right hand side of the appliance.
5. Continue to hold the control knob for an additional one (1) minute to ensure the pilot is
lit.
6. Turn control knob counterclockwise to the “ON” position. Push the
“ON/ OFF” toggle switch to the “ON” position. The main burner should light.
7. Close access panel door.
8. Turn on all electrical power to the appliance.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall Thermostat
needs to be set at a higher temperature than the room temperature.
Page 29
FLAME CHECK
Page 27
A periodic check of the flames should be made. The pilot flame should always be present when
the gas logs are in operation. See Figure 11.
FLAME:
• Propane (LP) should produce a flame that is about 6" above the rear log. This flame
should be yellow.
• Natural gas should produce a flame that is about 3" to 4" above rear log. This flame should
be mostly blue except foot the top tips which should be yellow.
Natural
PILOT
Figure 11
Propane
PILOT
Page 30
WIRING DIAGRAM
T
Page 28
WARNING:
ELECTRICAL GROUNDING INSTRUCTION:
THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR
YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
NOTE: #PESBR084 Blower Motor
Rating: 120 volts/60HZ/1.1 Amps.
NOTE: For convenience, allow licensed electrician to install properly grounded
3-plug receptacle near unit.
THERMOSTAT
JUMPER
BLACK
RHEOSTA
BLACK
MOTOR
JUMPER
GREEN
POWER CORD
JUMPER
WHITE
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE
APPLIANCE
WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE
MATERIAL ON OR NEAR THE APPLIANCE.
NOTE: “If any of the original wire as supplied with the gas appliance must be
replaced, it must be replaced with a wire of at least a 105
NOTE: Installation and repair should be done by a qualified service person.
This heater should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative that control compartments
and circulating air passageways of the heater be kept clean.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation.
Verify proper operation after servicing.
o
C. temperature rating.”
Page 31
IMPORTANT SAFEGUARDS
Page 29
Although your gas logs are very realistic in appearance, it is not a real burning fireplace and must not be
used for burning rejected material.
• To avoid irreparable damage to the heater or personal injury, matches, paper, garbage, or any other
material must not be placed or thrown on top of the logs or into the flames.
• To avoid personal injury, do not touch hot surfaces when the heater is operating.
• Close supervision is necessary when the heater is being operated near children.
WARNING: THE LOGS ARE MANUFACTURED FROM
BONDED CERAMIC FIBER. THIS IS A COMMONLY USED
MATERIAL IN INDUSTRY WORLDWIDE. IN THE EVENT THAT A
LOG SHOULD BE REMOVED, CARE SHOULD BE TAKEN NOT TO
DAMAGE THE BONDED MATERIAL.
INTENTIONAL MISUSE OR DELIBERATELY FRAGMENTING THE
MATERIAL COULD LEAD TO INHALING FIBERS AND BE
HAZARDOUS TO YOUR HEALTH.
THIS HEATER IS INTENDED FOR USE AS A GAS HEATER
FIREPLACE AS DESCRIBED IN THESE INSTRUCTIONS. IT SHOULD
NOT BE USED FOR ANY OTHER PURPOSE.
CLEANING
CAUTION: BEFORE CLEANING OR MOVING THESE LOGS OR
OTHER PARTS OF THE HEATER, BE SURE TO READ THE ABOVE
SECTIONS ON “IMPORTANT SAFEGUARDS.”
The appliance must be turned “OFF” before cleaning inside the firebox (burn
area), make sure the pilot is “OFF” completely and the appliance has cooled.
• All cleaning should be carried out when the heater is cold. Limited cleaning is required
with normal use. Dusting the front of the base, the top of the piezo cover, or the control
knob panel may be required occasionally. Do not use cleaning fluids to clean the logs or
any other part of the heater.
• If the flames show unusual shapes or behavior, or if burner fails to ignite properly, the
burner holes may require cleaning. If this occurs, contact your nearest dealer to service the
heater.
• The heater can be cleaned by removing the logs. Lift the logs gently, as not to damage the
fiber pieces. The logs have been spot glued in place for shipping, use caution when
removing. Lift each log by holding it carefully at each end. Use a vacuum cleaner to
remove dust and loose particles from the base, logs and around the burner and ODS/Pilot.
Gloves are recommended to prevent fibers from breaking the skin. If skin is broken, clean
with soap and water.
WARNING: Failure to keep the primary air openings(s) of the burner(s) clean may result
in sooting and property damage.
Page 32
TROUBLE SHOOTING
Page 30
WARNING
TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING.
ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND
REPAIR HEATER.
CAUTION
NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN
ODS/PILOT. THIS CAN DAMAGE ODS/PILOT.
OBSERVED
PROBLEM
Igniter button is pressed no
spark at ODS/Pilot
OBSERVED
PROBLEM
Igniter button is pressed
Spark at ODS/Pilot
No Ignition
POSSIBLE
CAUSE
1. Igniter electrode positioned
incorrectly.
2. Igniter electrode broken
3. Igniter electrode not
connected to igniter cable
4. Igniter cable pinched or wet
5. Piezo igniter nut is loose
6. Broken igniter cable
7. Bad piezo igniter
POSSIBLE
CAUSE
1. Gas supply turned off or
manual shutoff valve is
closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
SOLUTION
1. Replace igniter
2. Replace igniter
3. Reconnect igniter cable
4. Free igniter cable if pinched
by any metal or tubing. Keep
igniter cable dry.
5. Tighten nut holding piezo
igniter to heater cabinet. Nut
is located inside heater
cabinet at top.
6. Replace igniter cable
7. Replace piezo igniter
SOLUTION
1. Turn on gas supply or open
manual shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while in
PILOT position.
Page 33
Page 31
OBSERVED
PROBLEM
ODS/PILOT lights but flame
goes out when control knob is
released
4. Air in gas lines when
installed
5. Depleted gas supply
6. ODS/Pilot is clogged
7. Gas regulator setting is not
correct
POSSIBLE
PROBLEM
1. Control knob is not fully
pressed in
2. Control knob not pressed in
long enough
3. Safety interlock system has
been triggered (if equipped)
4. Manual shutoff valve not
fully open
5. Thermocouple connection
loose at control valve.
6. Pilot flame not touching
thermocouple, which allows
thermocouple to cool,
causing pilot flame to go
out. This problem can be
caused by one or both of the
following:
A) low gas pressure
B) dirty or partially
clogged ODS/Pilot
7. Control valve damaged
4. Continue to hold down control
knob. Repeat igniting
operation until air is removed.
5. Contact local propane gas
company
6. Clean ODS/Pilot or replace
ODS/Pilot assembly
7. Replace gas regulator
SOLUTION
1. Press control knob completely
2. After ODS/Pilot lights keep
control knob pressed 30
seconds.
3. Wait 1 minute for safety
interlock system to reset.
4. Fully open manual shutoff
valve.
5. Hand tighten until snug, then
tighten 1/4 turn
6. A) contact local propane gas
company
B) Clean ODS/Pilot (See
Cleaning and Maintenance),
or replace ODS/Pilot
assembly
7. Replace valve control
Page 34
OBSERVED
Page 32
PROBLEM
Burner does not light after ODS/
Pilot is lit
Delayed ignition of burner
Burner backfiring during
combustion
Slight smoke or odor during
initial operation
Heater produces a whistling
noise when burner is lit
POSSIBLE
CAUSE
1. Burner orifice is clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Burner orifice is clogged or
damaged
2. Burner damaged
3. Gas regulator defective
1. Residues from manufacturing
process
1. Turning control knob to HI
position when burner is cold
(if equipped with this type of
valve)
2. Air in gas line
3. Air passageways on heater
blocked
4. Dirty or partially clogged
burner orifice
SOLUTION
1. Clean burner (see Cleaning
and Maintenance) or replace
burner orifice
2. Contact local propane gas
company
1. Contact local propane gas
company.
2. Clean burner (see Cleaning
and Maintenance) or replace
burner orifice
1. Clean burner (see Cleaning
and Maintenance) or replace
burner orifice
2. Replace burner
3. Replace gas regulator
1. Problem will stop after a few
hours of operation
1. Turn control knob to LOW
position and allow to warm
2. Operate burner until air is
removed from line. Call
local propane company to
check gas line.
3. Observe minimum
installation clearances
4. Clean burner or replace
orifice
Page 35
WARNING
Page 33
IF YOU SMELL GAS:
* SHUT OFF GAS SUPPLY
* DO NOT TRY TO LIGHT APPLIANCE
* DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY
PHONE IN YOUR BUILDING
* IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S
PHONE. FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.
* IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
IMPORTANT: Operating heater where impurities in the air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc. create
fumes. These fumes may mix with combustion air and create odors.
OBSERVED
PROBLEM
Heater produces a clinking/
ticking noise just after burner is lit
or shut off
Heater produces unwanted odors
Heater shuts off in use
(ODS operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
POSSIBLE
CAUSE
1. Metal expands while heating
or contracts while cooling.
1. Heater burning vapors from
paint, hairspray, glues, etc.
(See Important above)
2. Low fuel supply
3. Gas leak (See WARNING
above)
1. Not enough fresh air is
available.
2. Low line pressure
3. ODS/Pilot is partially clogged
1. Gas leak (See WARNING,
above).
2. Control valve defect
1. Foreign matter between
control valve and burner
2. Gas leak (See WARNING,
above).
SOLUTION
1. This is common with most
heaters. If noise is excessive,
contact a qualified service
person.
1. Ventilate room. Stop using
odor causing products while
heater is running.
2. Refill supply tank.
3. Locate and control all leaks.
See Checking Gas
Connections.
1. Open window/door for
ventilation
2. Contact local propane co.
3. Clean ODS/Pilot
1. Locate and correct all leaks
(see Checking Gas
Connections)
2. Replace control valve
1. Remove foreign matter from
gas tubing
2. Locate and correct all leaks
(see Checking Gas
Connections).
Page 36
SERVICING
Page 34
Repair and replacement work should only be performed by a qualified service technician.
Always shut off the gas supply and make sure heater is cool before beginning any service
operation. Check for gas leaks after servicing.
REPAIR PARTS
A parts list with exploded view follows. Always include correct name, part number, and model
number of the heater when ordering service parts. Please contact your local dealer or Distributor
when ordering, or if one is not available, you may contact:
New Buck Corporation
P.O. Box 69
Spruce Pine, NC 28777
(828)-765-6144
Page 37
REPLACEMENT PARTS
Page 35
ITT VALVE
(Picture on page 36)
KEY# PART DESCRIPTION PART NUMBER
1. Female Terminals PE 5X425
2. Regulator (LP) Maxitrol PE RV 12LF90
2. Regulator (NAT) Maxitrol PE RV 12LF30
3. Pilot (NAT) Copreci PE 2150053 - NAT
3. Pilot (LP) Copreci PE 2150054 - LP
4. Generator ITT PE G251F245
5. Carling Switch PE RA911VB
6. Piezo Striker PE 124461
7. Piezo 14" Igniter Wire PE UL3304
8. Pilot Tube 1/4" MF 147AL
9. Burner Tube 3/8" PO 38117ALMTUB
10. 3/8" Supply Tube PO 38812ALMTUB
11. 3/8" IPT Male & Female Connector PH 4866
12. 3/8" x 3/8" Elbow (Brass) PH 4966
13. Jumper Wire 6" PE 65 JUMPER
14. Burner PO DTBURN
15. Orifice Holder PO 54ORFHLD
16. Orifice PO ORIFICE
17. Valve (LP) ITT PE B67SA-233
17. Valve (NAT) ITT PE B67RA-234
18. Burner Base PO 300010
19. 1/8" x 1/4" Compression Adapter PH 6842
20. Regulator Tube 1/4" MF 147AL
OTHER PARTS (NOT SHOWN)
21. Fan Motor PE SBRO84
22. Power Cord PE 400240
23. Strain Release PE 400320
24. Thermostat PE 400130
25. Male Terminals PE 5X428
26. Jumper Wire 12" PE 12JUMPER
27. Gas Log Set PO C-3329
28. Fan Speed Control Label PE KB9724
29. Rheostat PE BC 204
30. Rheostat Knob PE BC 204A
31. Heyco 1-1/4" Grommet PE HEYCO2883
Page 38
14
Page 36
18
8
19
16
9
2
20
THERMO
GEN
AUX
12
ITT
GENERAL
CONTROLS
3
7
4
13
6
1
15
17
T
O
ADJ
PILOT
10
N
O
L
I
P
11
T
E
S
E
R
O
T
SS
E
R
P
OFF
ON
5
Page 39
REPLACEMENT PARTS
Page 37
SIT (MODULATING) OR (MANUAL) VALVE
(Picture on page 38)
KEY# PART DESCRIPTION PART NUMBER
1. Pilot (NAT) Copreci PE 2150053 - NAT
1. Pilot (LP) Copreci PE 2150054 - LP
2. Thermopile (Copreci) PE TPT100 / 90
3. Pilot Tube 1/4" MF 147AL
4. Burner Tube 3/8" PO 3817ALMTUB
5. 3/8" x 3/8" Elbow PH 4966
6. Burner PO DTBURN
7. Orifice Holder PO 54ORFHLD
8. Orifice PO ORIFICE
9. Valve (LP) SIT (Modulating) PE 0630504
9. Valve (NAT) SIT (Modulating) PE 0630504
9A. Valve (LP) SIT (Manual) PE0630.522
9A Valve (NAT) SIT (Manual) PE0630.522
10. Burner Base PO 300010
11. Valve Regulator (LP) Maxitrol PE RV20LF90
11. Valve Regulator (NAT) Maxitrol PE RV20LF35
Black Pipe:
12. 3/8" 90 Degree Elbows (2) PO 3890ELB
13. 3/8" x 1-1/2" Nipples (1) PO 38112BINIP
14. 3/8" x 3-1/2" Nipples (2) PO 38312BINIP
15. 3/8" Supply Tube PO 381434ALMTUB
16. 3/8" IPT Male & Female Connector PH 4866
17. Pilot Regulator (LP) Maxitrol PE RV 122F90
17. Pilot Regulator (NAT) Maxitrol PE RV 122F30
OTHER PARTS (NOT SHOWN)
18. Fan Motor PE SBRO84
19. Power Cord PE 400240
20. Strain Release PE 400320
21. Thermostat PE 400130
22. Male Terminals PE 5X428
23. Jumper Wire 12" PE 12JUMPER
24. Gas Log Set PO C-3329
25. Fan Speed Control Label PE KB9724
26. Rheostat PE BC 204
27. Rheostat Knob PE BC 204A
28. Heyco 1-1/4" Grommet PE HEYCO2883
Page 40
10
Page 38
6
5
12
16
11
L
O
14
PILOT
Sit
F
F
O
12
13
9
I
H
8
7
15
17
3
5
2
6
13
1
Page 41
NEW BUCK CORPORATION
Page 39
We reserve the right to amend these specifications at any time without notice. The only
warranty applicable is our standard written warranty. We offer no other warranty, expressed or
implied.
LIMITED WARRANTY
MODEL FP-32
New Buck warrants this product to be free from defects in materials and components for two (2)
years from the date of first purchase, provided that the product has been properly installed,
operated, and maintained in accordance with all applicable instructions. To make a claim under
this warranty the Bill of Sale or canceled check must be presented.
This warranty is extended only to the original retail purchaser and covers the cost of parts
required to restore the heater to proper condition. Warranty parts MUST be obtained through
an authorized Buck Stove dealer and/or New Buck, who will provide original factory
replacement parts. Failure to use original factory replacement parts voids this warranty. The
heater must be installed by a qualified installer in accordance with all local codes and
instructions furnished with the unit.
Warranty does not apply to parts that are not in original condition, normal wear and tear, or
parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance
or defects caused by improper installation.
WARRANTY DOES NOT COVER:
- Removal and re-installation cost
- Labor costs for replacements or repairs
- Transportation
- Cost of service call to diagnose trouble
- Painted surfaces
- Damage or defect caused by improper installation, accident, misuse, abuse, or alteration
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT
GOVERNS THE SALE OF THE PRODUCT, THIS EXPRESS WARRANTY EXCLUDES
ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF
ANY AND ALL WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR FROM THE DATE
OF FIRST PURCHASE. NEW BUCK LIABILITY IS HEREBY LIMITED TO THE
PURCHASE PRICE OF THE PRODUCT AND NEW BUCK SHALL NOT BE LIABLE FOR
ANY OTHER DAMAGES WHATSOEVER INCLUDING INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or
limitation of incidental or consequential damages, so the above limitation on implied warranties
or exclusion on damages may not apply to you.
This warranty gives you specific legal rights. Other rights may vary from state to state
Page 42
Page 40