A.2 Recycling information ..................................................................................................... 14
nevion.com | 3
Page 4
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
SDI-CHO-2x1
2x1 SD-SDI changeover
SDI-CHO-2x1-PB
2x1 SD-SDI change over with passive bypass
Figure 1 - SDI-CHO-2x1 Serial Digital Video Change-over
1 Product overview
The flashlink SDI-CHO-2x1-PB/SDI-CHO-2x1 is a serial digital video 2x1 change-over
module providing high performance line protection for various signal formats from
1Mbps up to 540Mbps. The unit can be configured to perform cable equalizing and reclocking of SMPTE 259M and DVB-ASI signal formats. The switching criteria can be
selected to be based on loss of input signal or loss of lock (re-clocker). The switch can
either be latching or non-latching (in loss of lock mode, only latching switch is
available). It is also possible to control the switch with GPI inputs, with the GYDA
system controller or with the open protocol RS422 interface.
The two inputs typically provide automatic cable equalizers for up to 300 meters of
cable (Belden 8281A at 270Mbps) with a 2 x 1 switch in front of a re-clocker with 4
outputs. The re-clocker supports the bit-rates; 143, 177, 270, 360 and 540Mbps. For
other rates, the re-clocker automatically switches to bypass mode and the SDI-CHO2x1 will work as a non-re-clocking 2x1 change-over unit with cable equalizer. The SDICHO-2x1 also has a special DVB-ASI mode, enabling all possible rates including
empty transport streams with only K28.5 padding packets. 2 outputs are non-inverting
to support DVB-ASI compatibility.
The SDI-CHO-2x1 is designed for various line protection applications for studio,
campus, broadcast and telecom. The SDI-CHO-2x1-PB also features a relayed bypass
of both inputs to its respective outputs ensuring signal bypass at power down or card
failure/ upgrade.
New in firmware version 2.0.0 or newer: When latched to standby input, latch will not
hold against missing signal on standby input if the signal on main input has been
restored. Also, a secondary timer has been added, which handles de-bouncing of the
“signal on main input returns” condition. The primary timer handles de-bouncing of LOS
on both main and standby inputs.
1.1 Product versions
nevion.com | 4
Page 5
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
2 Specifications
Electrical Input
Number of inputs: 2
Data rate NRZ: 1 to 540 Mbps
Equalization: Automatic (typical up to 300m Belden
8281A)
Cable reclocker can be bypassed to
support
bit rates down to 1Mbps.
Impedance: 75 ohm
Return loss: >15dB @ 540MHz
Signal level: nom. 800mV
apx. 200mV min. when equalizer switched
to Bypass
Connector: BNC
Electrical Output
Number of outputs: 4
Connector: BNC
Impedance: 75 ohm
Return loss: >15dB @ 540MHz
Jitter: max 0.2UI
Peak to peak signal level: 0.8V 0.1V
Signal polarity 2 outputs non inverting, 2 outputs inverting
Power: +5V DC / 3W Max.
Control: Control system for access to setup and
module status
With BITE (Built-In Test Equipment) for
use with Multicon Gyda Control System
Supported standards
SMPTE: SMPTE259M, SMPTE305.2M,
SMPTE310M, SMPTE344M
DVB-ASI: EN50083-9
nevion.com | 5
Page 6
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
Switch #
Label
Function DIP=OFF
Function DIP=ON
Comment
1
LTC
Non-latching switch. Will
automatically return to main
when input signal present
Latching switch. Must be reset
to return from standby to main
“Sticky” switching
2
IN1
Input 2 priority
Input 1 priority
Select main input
3
L/R
Loss of signal based switch
decision
Reclocker based switch
decision
Signal integrity
decision
4
TME
Ripple rejection OFF
Ripple rejection ON (variable
delay)
Timing
5
RCL
Reclocker Bypass
Reclocker ON
Reclocker mode
6
EQ
Cable equaliser Bypass
(Loss of signal based switch
decision will not work on this
mode)
Cable equaliser ON
Equaliser mode
7
ASI
SDI 177Mbps Reclocker
support
DVB-ASI Reclocker support
ASI mode
8
OVR
GYDA control
Config. with GYDA
Override GYDA control
Config. with DIP switch
Select GYDA
config. mode
Figure 2 - SDI-CHO-2x1 board layout
3 Format Configuration
The SDI-CHO-2x1/-PB can support a number of different formats. The correct
configuration can either be set with a DIP switch or with the Multicon Gyda Control
System. The layout of SDI-CHO-2x1 is shown in the drawing below with the DIP switch
to the upper left position.
DIP switch configuration must be set according to the table below:
All DIP switches are off when pointing towards the release handle.
When the default setting is selected, all clock rates for SDI and DVB-ASI are
automatically configured by the module itself.
nevion.com | 6
Page 7
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
3.1 Configuration Examples
Typical configurations for SDI-CHO-2x1:
Figure 3 - Default for SDI or DVB-ASI;
Non-latching, Input1=main, LOS based, Reclocking, Ripple rejection OFF
Figure 4 - SDI or DVB-ASI; Latching, Reclocker based decision
Figure 5 - Transparent Mode for Non-supported rates with Ripple rejection timer;
Latching, LOS based decision, Time ON, reclocking OFF
nevion.com | 7
Page 8
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
4 Connections
The SDI-CHO-2x1 and SDI-CHO-2x1-PB has dedicated connector modules, SDI-CHO2x1-C1 and FRS-HD-CHO-C1. These modules are mounted at the rear of the subrack. The modules are shown in the figure below.
The electrical input signals are connected to the IN1 and IN2 BNC’s. The electrical
outputs are connected to the O1 to O4 BNC’s. Please note that only 2 outputs are non-
inverted and suitable for DVB-ASI. The Sync input connectors are not in use on this
product.
The details of how the connector module is mounted, is found in the user
manual for the sub-rack frame FR-2RU-10-2-xx.
This manual is also available from our web site: http://www.nevion.com/
4.1 Mounting the connector module.
The details of how the connector module is mounted, is found in the user manual for
the sub-rack frame FR-2RU-10-2-xx.
This manual is also available from our web site: http://www.nevion.com/
nevion.com | 8
Page 9
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
Signal
Name
Pin #
Mode
Direction
Status
General error status for the
module.
Pin 1
Open Collector
Output
LOS
Loss Of Signal at selected input
Pin 2
Open Collector
Output
Input 1
Input 1 selected (IN1)
Pin 3
Open Collector
Output
Input 2
Input 2 selected (IN2)
Pin 4
Open Collector
Output
Reset
Reset selected input to main
Pin 5
TTL, 0V =
active level
Input
Set
Set selected input to standby
Pin 6
TTL, 0V =
active level
Input
Ground
0 volt pin
Pin 8
0V.
5 Module status
The status of the module can be monitored in three ways.
1. GYDA System Controller (optional).
2. GPI at the rear of the sub-rack.
3. LED’s at the front of the sub-rack.
Of these three, the GPI and the LED’s are mounted on the module itself, whereas the
GYDA System Controller is a separate module giving detailed information on the card
status. The functions of the GPI and the LED’s are described in sections 5.1 and 5.2.
The GYDA controller is described in a separate user manual.
5.1 GPI ALARM and Control – Module Status Outputs and
selection of inputs
These outputs can be used for wiring up alarms for third party control systems. The
GPI outputs are open collector outputs, sinking to ground when an alarm is triggered.
The GPI connector is shown in figure 7.
The two GPI inputs can be used to control switching of inputs.
Electrical Maximums for GPI outputs
Max current: 100mA
Max voltage: 30V
SDI-CHO-2X1 module GPI pinning:
Figure 7 - GPI Pin layout
nevion.com | 9
Page 10
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
Diode \ state
Red LED
Yellow LED
Green LED
No light
Status
Module is faulty
Module is OK
Module power is OK
Module has no
power
Lock&LOS
Loss Of Signal & No
Reclocker lock
Signal present & No
Reclocker lock
Signal present &
Reclocker in lock
Input 1
No input signal on
Input 1
Signal present & not
selected
Signal present &
Input 1 selected
Input 2
No input signal on
Input 2
Signal present & not
selected
Signal present &
Input 2 selected
5.2 Front Panel - Status Monitoring
The status of the module can be easily monitored visually by the LED’s at the front of
the module. The LED’s are visible through the front panel as shown in figure 8 below.
Figure 8 - Front panel indicator overview for SDI-CHO-2x1 ((Text not printed on the front
panel).
The SDI-CHO-2x1 has 4 LED’s each showing a status corresponding to the GPI
pinning. The position of the different LED’s is shown in figure 8.
nevion.com | 10
Page 11
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
Command
Response
Comment
?
See protocol description
The “hello” command
info
Module status information
reset
OK
Reset latch to main input channel.
set auto
OK
Set to automatic input channel selection. Automatic input
selection enabled.
set main
OK
Set to main input channel. Automatic input selection
disabled.
set standby
OK
Set to standby input channel. Automatic input selection
disabled.
timer off
OK
Switch off time delay for input selection automatics
timer on
OK
Switch on time delay for input selection automatics
timer xx
OK
xx is the delay time for the timer. For firmware version
2.0.0 or newer, this is only used for switching from main
to standby. (Value stored in EEPROM)
timer_rst xx
OK
xx is the delay time for the secondary timer, used on FW
2.0.0 or newer to reset back to main. (Value stored in
EEPROM)
mode los
OK
Input selection automatics based on loss of signal
mode rcl
OK
Input selection automatics based on reclocker in lock
asi on
OK
Set DVB-ASI Reclocker support
asi off
OK
Set SDI 177Mbps Reclocker support
latch on
OK
Latching switch. Must be reset to return from standby to
main
latch off
OK
Non-latching switch. Will automatically return to main
when input signal is present
rcl on
OK
Reclocker on
rcl off
OK
Reclocker Bypass
eq on
OK
Cable equaliser on
eq off
OK
Cable equaliser Bypass (Los of signal based switch
decision will not work on this mode)
main 1
OK
Input 1 configured as main. Input 2 is standby.
main 2
OK
Input 2 configured as main. Input 1 is standby.
6 Interface with GYDA and RS-422 command set
All commands follow the flashlink protocol and can be used for direct control access to
the modul. The control system can either be a GYDA-SC or a third-party control
system with integrated flashlink protocol. The module can also be manually controlled
with a VT100 compatible terminal program.
The protocol can be found on our web page; http://www.network-electronics.com
6.1 SDI-CHO-2x1 Command table
nevion.com | 11
Page 12
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
1.
The equipment will meet the guaranteed performance specification
under the following environmental conditions:
-
Operating room
temperature range:
0°C to 40°C
-
Operating relative humidity
range:
<90% (non-condensing)
2.
The equipment will operate without damage under the following
environmental conditions:
-
Temperature range:
-10°C to 50°C
-
Relative humidity range:
<95% (non-condensing)
General environmental requirements for Nevion equipment
nevion.com | 12
Page 13
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
Product Warranty
The warranty terms and conditions for the product(s) covered by this manual follow the
General Sales Conditions by Nevion, which are available on the company web site:
www.nevion.com
nevion.com | 13
Page 14
SDI-CHO-2x1/ SDI-CHO-2x1-PB Rev. E
組成名稱
Part Name
Toxic or hazardous substances and elements
鉛
Lead
(Pb)
汞
Mercury
(Hg)
镉
Cadmium
(Cd)
六价铬
Hexavalent
Chromium
(Cr(VI))
多溴联苯
Polybrominated
biphenyls
(PBB)
多溴二苯醚
Polybrominated
diphenyl ethers
(PBDE)
SDI-CHO-2x1
SDI-CHO-2x1-PB
O O O O O
O
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is
below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used
for this part is above the limit requirement in SJ/T11363-2006.
Appendix A Materials declaration and recycling
information
A.1 Materials declaration
For product sold into China after 1st March 2007, we comply with the “Administrative
Measure on the Control of Pollution by Electronic Information Products”. In the first
stage of this legislation, content of six hazardous materials has to be declared. The
table below shows the required information.
This is indicated by the product marking:
A.2 Recycling information
Nevion provides assistance to customers and recyclers through our web site
http://www.nevion.com/. Please contact Nevion’s Customer Support for assistance with
recycling if this site does not show the information you require.
Where it is not possible to return the product to Nevion or its agents for recycling, the
following general information may be of assistance:
Before attempting disassembly, ensure the product is completely disconnected
from power and signal connections.
All major parts are marked or labeled to show their material content.
Depending on the date of manufacture, this product may contain lead in solder.
Some circuit boards may contain battery-backed memory devices.
nevion.com | 14
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.