Nevion DA-AES User Manual

Page 1
DA-AES
User manual
Rev. J
Nevion
Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99
nevion.com
Page 2
DA-AES Rev. J
Nevion Europe P.O. Box 1020
3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99
Nevion USA
1600 Emerson Avenue
Oxnard, CA 93033, USA
Toll free North America: (866) 515-0811
Outside North America: +1 (805) 247-
8560
E-mail: support@nevion.com
See http://www.nevion.com/support/ for service hours for customer support globally.
Rev.
Repl.
Date
Sign
Change description
J 8 2015-05-14
MB
Cover page update; DoC removed; no other changes to content
8 7 2012-06-12
AA /
JRW
New template.
7 6 2008-07-14
Added Declaration of Conformity.
6 5 2007-10-25
New front page and removed old logo.
5 4 2007-10-05
Added Materials Declaration and EFUP
4 3 2005-10-05
Removed comment regarding Gyda override chapter 3
3 2 2004-11-16
Gyda override description corrected chapter 4
2 1 2004-11-10
Errors regarding pin numbering corrected in chapter 4
1 0 2004-10-12
Changed from Gyda to DIP in chapter 3. Changed 1:4 cross mode.
0 A 2004-04-27
Changed chapter 3
A - 2004-01-23
Preliminary version
Nevion Support
Revision history
Current revision of this document is the uppermost in the table below.
nevion.com | 2
Page 3
DA-AES Rev. J
Contents
Revision history ...................................................................................................................... 2
1 Product overview ................................................................................................................. 4
2 Specifications ................................................................................................ ...................... 5
3 Configuration ................................ ................................................................ ....................... 6
4 Connections ........................................................................................................................ 7
4.1 Connector module ............................................................................................................ 7
4.2 Mounting the connector module ....................................................................................... 8
5 Operation ............................................................................................................................ 9
5.1 Module status ................................................................................................................... 9
5.1.1 Front panel – status monitoring ..................................................................................... 9
5.2 Interface with GYDA and RS-422 command set ............................................................... 9
5.2.1 DA-AES command table ................................................................................................ 9
General environmental requirements for Nevion equipment ................................................. 11
Product Warranty ................................................................................................................. 12
Appendix A Materials declaration and recycling information ................................................. 13
A.1 Materials declaration ...................................................................................................... 13
A.2 Recycling information ..................................................................................................... 13
nevion.com | 3
Page 4
DA-AES Rev. J
1 Product overview
The DA-AES is a Digital Audio Distribution Amplifier. The DA-AES can be configured as either 1 input and 8 outputs or dual 1 input and 4 outputs. The Distribution Amplifier supports sample rate 15-96 kHz and has balanced inputs and outputs. The DA-AES is designed for all digital audio distribution purposes in studio, duplication and Broadcast applications.
Figure 1: DA-AES - AES distribution amplifier
nevion.com | 4
Page 5
DA-AES Rev. J
2 Specifications
Electrical Input:
Number of inputs: 1 or 2 Standard: AES-3 Supported Sample Rate: 15-96 kHz Signal Amplitude: 0.2-7Vp-p Connector: DB15 balanced Impedance: 110 ohms nominal
Electrical Output:
Number of outputs: 8 or 4+4 Connector: DB25 balanced Signal amplitude: 4Vp-p ±1Vp-p Impedance: 110 ohms nominal
Features:
Configurable dual 1 input to 4 outputs or single 1 input to 8 outputs
Electrical:
Power: +5V DC / 0.5 W Control: Control system for access to setup and module status
with BITE (Built-In Test Equipment) for use with GYDA Control System.
nevion.com | 5
Page 6
DA-AES Rev. J
SW1-1
SW1-2
SW1-3
Function
Off
Off
On
AES1 input to AES1 outputs, AES2 input to AES2 outputs
Off
On
On
AES1 input to AES2 outputs, AES2 input to AES1 outputs
On
Off
On
AES1 input to AES1 and AES2 outputs
On
On
On
AES2 input to AES1 and AES2 outputs
X X Off
Gyda controls the setting
3 Configuration
The DA-AES supports either single 1 input to 8 outputs or dual two inputs to 4 outputs.
DIP switch SW1-4 is reserved for future options. When DIP switch 1-3 is on, LEDs should blink when DIP switch 1-1 or 1-2 is changed.
nevion.com | 6
Figure 2: DA-AES board layout
Page 7
DA-AES Rev. J
Function
Pin
AES channel 1 positive input (AES1 +)
7
AES channel 1 negative input (AES1 –)
15
AES channel 2 positive input (AES2 +)
10
AES channel 2 negative input (AES2 –)
3
Ground
2, 5, 8, 11, 14
Function
Pin
AES channel 1 positive output 1
24
AES channel 1 negative output 1
12
AES channel 1 positive output 2
10
AES channel 1 negative output 2
23
AES channel 1 positive output 3
21
AES channel 1 negative output 3
9
AES channel 1 positive output 4
7
AES channel 1 negative output 4
20
AES channel 2 positive output 1
18
AES channel 2 negative output 1
6
AES channel 2 positive output 2
4
AES channel 2 negative output 2
17
AES channel 2 positive output 3
15
AES channel 2 negative output 3
3
AES channel 2 positive output 4
1
AES channel 2 negative output 4
14
Ground
2, 5, 8, 11,13, 16,19,22,25
4 Connections
4.1 Connector module
Figure 3: Overview of the AES-C1 connector module
The DA-AES has a dedicated connector module: AES-C1. This module is mounted at the rear of the sub-rack. The module is shown in Figure 3. J4 is the input DSUB connector, while J6 is the output connector.
J4:
J6:
nevion.com | 7
Page 8
DA-AES Rev. J
4.2 Mounting the connector module
The details of how the connector module is mounted, is found in the user manual for the sub-rack frame FR-2RU-10-2.
This manual is also available from our web site: http://nevion.com
nevion.com | 8
Page 9
DA-AES Rev. J
Command
Response
Comment
?
See protocol description
The “hello” command
info
Module status information
reset
OK
Set input configuration to DIP switch setting
set norm8
OK
Set AES1 input to AES1 and AES2 outputs
set norm4
OK
Set AES1 input to AES1 outputs and AES2 input to AES2 outputs
set cross8
OK
Set AES2 to AES1 and AES2 outputs
set cross4
OK
Set AES1 input to AES2 outputs and AES2 input to AES1 outputs
Diode \
state
Red LED
Yellow LED
Green LED
No light
Status
Module is faulty
Module is OK Module power is OK
Module has no power
Signal on ch1
Signal not present
Signal present
Signal on ch2
Signal not present
Signal present
5 Operation
5.1 Module status
The status of the module can be monitored in two ways:
1. GYDA System Controller (optional). GYDA System Controller is a separate module giving detailed information on the card status. The GYDA controller is described in a separate user manual.
2. LEDs at the front of the sub-rack. LEDs are mounted on the module itself. The functions of the LEDs are described in sections 5.1.
5.1.1 Front panel – status monitoring
The status of the module can be easily monitored visually by the LEDs at the front of the module. The LEDs are visible through the front panel. The LED on top tells if the DA-AES is ok or not (green LED means ok – red is alarm). The second and third LED tells if there is an AES stream present on one or both input channels. When data stream is present, the LED is green. If there is no data stream, the LED is red. The functions of the different LEDs are summarized in the table below.
5.2 Interface with GYDA and RS-422 command set
All commands follow the flashlink protocol and can be used for direct control access to the modul. The control system can either be a GYDA-SC or a third-party control system with integrated flashlink protocol. The module can also be manually controlled with a VT100 compatible terminal program.
The protocol can be found on our web page; http://nevion.com
5.2.1 DA-AES command table
nevion.com | 9
Page 10
DA-AES Rev. J
nevion.com | 10
Page 11
DA-AES Rev. J
1.
The equipment will meet the guaranteed performance specification under the following environmental conditions:
-
Operating room temperature range:
0°C to 45°C
-
Operating relative humidity range:
<90% (non-condensing)
2.
The equipment will operate without damage under the following environmental conditions:
-
Temperature range:
-10°C to 50°C
-
Relative humidity range:
<95% (non-condensing)
General environmental requirements for Nevion equipment
nevion.com | 11
Page 12
DA-AES Rev. J
Product Warranty
The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Nevion, which are available on the company web site:
www.nevion.com
nevion.com | 12
Page 13
DA-AES Rev. J
組成名稱
Part Name
Toxic or hazardous substances and elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
六价铬
Hexavalent
Chromium
(Cr(VI))
多溴联苯
Polybrominated
biphenyls
(PBB)
多溴二苯醚
Polybrominated
diphenyl ethers
(PBDE)
DA-AES
O O O O O
O
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006.
Appendix A Materials declaration and recycling information
A.1 Materials declaration
For product sold into China after 1st March 2007, we comply with the “Administrative Measure on the Control of Pollution by Electronic Information Products”. In the first
stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information.
This is indicated by the product marking:
A.2 Recycling information
Nevion provides assistance to customers and recyclers through our web site
http://www.nevion.com/. Please contact Nevions Customer Support for assistance with
recycling if this site does not show the information you require. Where it is not possible to return the product to Nevion or its agents for recycling, the
following general information may be of assistance:
Before attempting disassembly, ensure the product is completely disconnected
from power and signal connections.
All major parts are marked or labeled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices.
nevion.com | 13
Loading...