Nevion DA -3GHD 3GHD -8-PL, DA -3GHD 3GHD -8, DA-3GHD-8-PL, DA-3GHD-8 User Manual

Page 1
Nevion HQ:
Nevion Europe, P.O. Box 1020, 3204 Sandefjord, Norway
Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com
DA-3GHD-8-PL / DA-3GHD-8
with or without passive loop-through
User manual
Rev. 3
Page 2
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 2
Nevion Support
Nevion Europe P.O. Box 1020
3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99
Nevion USA
1600 Emerson Avenue
Oxnard, CA 93033, USA
Toll free North America: (866) 515-0811
Outside North America: +1 (805) 247-8560
E-mail: support@nevion.com
See http://www.nevion.com/support/ for service hours for customer support globally.
Revision history
Current revision of this document is the uppermost in the table below.
Rev.
Repl.
Date
Sign
Change description
3 2 2012-06-18
SHH
- Updated chapter 4 that slot 1 cannot be used for 3G-SDI.
2 1 2012-04-23
RB
- Updated table 2 with corrections of LED functions.
- Specifies in chapter 4 that slot 1 cannot be used
with current product revision.
1 0 2012-01-09
RB
- Added the product DA-3GHD-8 to the document.
- Updated table for cable equalization.
0 - 2011-10-10
RB
Release revision (not published)
Page 3
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 3
Contents
Revision history .......................................................................................................... 2
1 Product overview ..................................................................................................... 4
2 Specifications .......................................................................................................... 5
2.1 Electrical Outputs ............................................................................................................ 5
2.2 Electrical Inputs ............................................................................................................... 5
2.3 Features .......................................................................................................................... 7
2.4 Supported standards ....................................................................................................... 7
2.5 General ........................................................................................................................... 7
3 Configuration ........................................................................................................... 8
3.1 Configuration Examples................................................................................................... 9
4 Connections ........................................................................................................... 10
5 Operation ............................................................................................................... 12
General environmental requirements for Nevion equipment..................................... 13
Product Warranty ...................................................................................................... 14
Appendix A Materials declaration and recycling information..................................... 15
A.1 Materials declaration ......................................................................................................15
A.2 Recycling information .....................................................................................................15
EC Declaration of Conformity ................................................................................... 16
Page 4
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 4
1 Product overview
The Flashlink DA-3GHD-8-PL and DA-3GHD-8 is a multi bit-rate distribution amplifier module providing high performance media distribution for various signal formats from 19.4Mbps up to 2970Mbps. The unit can be configured to do cable equalizing and reclocking of SMPTE 424M, SMPTE 292 and SMPTE 259M signal formats.
Both modules provide 8 reclocked non-inverting outputs, and the DA-3GHD-8-PL also provides a passive loop-through output. The passive loop-through output facilitates distribution of the source signal to multiple cards without corruption due to powerdown or removal of cards. The passive loop-through output must be terminated into 75 ohm, either by connecting it to a subsequent DA-3GHD-8-PL, or by attaching a 75 ohm BNC terminator.
Both modules will detect HD and SD rates and automatically switch to correct output slew­rate. The reclocker supports the bit-rates 270Mbps, 1483.5Mbps, 1485Mbps, 2967Mbps and 2970Mbps. For other rates the reclocker can automatically switch to bypass mode and the DA-3GHD-8-PL/DA-3GHD-8 will work as a non-reclocking distribution amplifier with cable equalizer. The DA-3GHD-8-PL/DA-3GHD-8 also supports reclocking of DVB-ASI at 270Mbps, enabling all possible rates including empty transport streams with only K28.5 padding packets. All 8 outputs (and the passive loop-through output) are non-inverting and suitable for DVB-ASI.
The DA-3GHD-8-PL/DA-3GHD-8 is designed for all distribution purposes in studio, duplication and Broadcast applications.
Figure 1: DA-3GHD-8-PL / DA-3GHD-8
Reclocker
EQ
Microcontroller
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
Remote Control
Bypass
Passive Loop­Through (-PL version only)
Bypass
Format
IN
Page 5
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 5
2 Specifications
2.1 Electrical Outputs
Number of outputs
8 reclocked 1 passive loop-through (-PL version)
Connectors
75 Ohm BNC
Output Return loss
- < -15dB, 5MHz -1.5GHz
- < -10dB, 1.5GHz - 3GHz
Output signal level
800mV +/- 10%
Output signal rise / fall time 20% - 80%
- SD limit: [0.4ns – 1.5ns]; <0.5ns rise/fall var.
- HD limit: < 270ps, <100ps rise/fall var.
- 3G HD limit: <135ps, <50ps rise/fall var.
Amplitude overshoot
<10%
Polarity
- All outputs are non-inverting
Output timing jitter
- SD: <0.2 UI
- HD: <1 UI
- 3G HD: <1UI
Output alignment jitter
- SD: <0.15 UI
- HD: <0.15 UI
- 3G HD: <0.2UI
2.2 Electrical Inputs
Number of inputs
1
Connectors
75 Ohm BNC
Input Return loss
- < -15dB, 5MHz -1.5GHz
- < -10dB, 1.5GHz - 3GHz
Jitter tolerance
- SD limit:
- 10Hz-10kHz: >1 UI
- 10kHz-10MHz: >0.2 UI
- HD limit:
- 10Hz-100kHz: >1 UI
- 100kHz-150MHz: >0.2 UI
- 3G HD limit:
- 10Hz-100kHz: >2 UI
- 100kHz-300MHz: >0.3 UI
Page 6
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 6
Cable equalization, DA-3GHD-8.
Format
Min.
Typical
Comments
SD-SDI
300m
Belden 8281 BER< 10E-12 Total length of cable included patching between modules
325m HD-SDI
150m
Belden 1694A BER< 10E-12 Total length of cable included patching between modules
200m
3GHD-SDI
70m
100m
Cable equalization, DA-3GHD-8-PL, single unit.
Format
Min.
Typical
Comments
SD-SDI
200m1,2
Belden 8281 BER< 10E-12 Total length of cable included patching between modules
225m
2,3
HD-SDI 50m
1,2
Belden 1694A BER< 10E-12 Total length of cable included patching between modules
75m
2,3
3GHD-SDI
30m
1,2
40m
2,3
Cable equalization, DA-3GHD-8-PL, two looped units.
Format
Min.
Typical
Comments
SD-SDI
200m
1,2
Belden 8281 BER< 10E-12 Total length of cable included patching between modules
225m
2,3
HD-SDI 50m
1,2
Belden 1694A BER< 10E-12 Total length of cable included patching between modules
60m
2,3
3GHD-SDI
25m
1,2
25m
2,3
Cable equalization, DA-3GHD-8-PL, three looped units.
Format
Min.
Typical
Comments
SD-SDI
175m
1,2
Belden 8281 BER< 10E-12 Total length of cable included patching between modules
200m
2,3
HD-SDI 30m
1,2
Belden 1694A BER< 10E-12 Total length of cable included patching between modules
50m
2,3
3GHD-SDI
15m
1,2
20m
2,3
1
Measured with the following parameters at the limits of the standards simultaneously;
Amplitude (+/- 10%), Ambient temperature (0ºC/45ºC), Generator jitter:
- SD-SDI: 10Hz-10kHz: >1 UI 10kHz – 10MHz: >0.2 UI
- HD-SDI: 10Hz-100kHz: >1 UI 100kHz–150MHz: >0.2 UI
- 3GHD-SDI: 10Hz-100kHz: >2 UI 100kHz–300MHz: >0.3 UI
2
Specified termination at the loop end required. 75 ohm terminations mounted at all unused output ports for HD-SDI and 3GHD-
SDI required.
3
Well within limits of standards
Page 7
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 7
2.3 Features
Re-clocking:
Automatic SD/ HD detection
Automatic output slew rate adjustment according to SMPTE­259M and SMPTE-292M/ SMPTE424M
Supported clock rates:
270, 1483.5, 1485, 2967, 2970Mbps
Input equalizer:
Eq. bypass for non-video formats or low bit rates
2.4 Supported standards
SMPTE:
SMPTE424M, SMPTE292M, SMPTE259M, SMPTE305M, SMPTE310M
DVB-ASI:
EN50083-9
2.5 General
DC power consumption:
+5V / 1.4W
Page 8
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 8
3 Configuration
The DA-3GHD-8-PL/DA-3GHD-8 supports a number of different formats. The correct configuration can either be set with a DIP switch or with GYDA Control System. The layout of DA-3GHD-8-PL/DA-3GHD-8 is shown in the drawing below with the DIP switch to the upper left position.
Figure 2: DA-3GHD-8-PL/DA-3GHD-8 module layout
DIP switch configuration must be set according to Table 1:
Switch #
Label
Function DIP=OFF
Function DIP=ON
Comment
1
---
2
---
3
---
4
---
5
ABYP
No auto bypass
Reclocker bypass if unsupported bitrate
Auto bypass of reclocker
6
RCL
Reclocker Bypass
Reclocker ON
Reclocker mode
7
EQ
Cable equalizer Bypass
Cable equalizer ON
Equalizer mode
8
OVR
GYDA control Config. with GYDA
Override GYDA control Config. with DIP switch
Select GYDA config. mode
Table 1: DA-3GHD-8-PL/DA-3GHD-8 DIP switches
All DIP switches are off when pointing towards the release handle.
Page 9
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 9
3.1 Configuration Examples
Typical configurations for DA-3GHD-8-PL/DA-3GHD-8:
Figure 3: Default all off; Gyda controls the card
Figure 4: DIP control; Equalizing and reclocking turned on
Figure 5: Same as above, but if the input signal is something else than the supported bit-rates,
the reclocker will automatically enter bypass mode
- - -
- - -
- - -
- - -
ABYP
RCL
EQ
OVR
ON
1 8 - - -
- - -
- - -
- - -
ABYP
RCL
EQ
OVR
ON
1 8 - - -
- - -
- - -
- - -
ABYP
RCL
EQ
OVR
ON
1
8
Page 10
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 10
4 Connections
Both module versions have a dedicated connector backplane which is mounted at the rear of the sub-rack. The backplane layout is shown in Figure 6.
Due to signal performance discrepancies in slot 1 (leftmost position), slot 1 may not be used with this product for 3G-SDI.
HD, SD and ASI meets is not affected and meets their respective performance specifications.
Figure 6: Layout of the backplanes DA-3GHD-8-PL-C1 and DA-3GHD-8-C1.
The electrical input signal is connected to the IN BNC. On the -PL version the signal is then passively looped to the LOOP-OUT BNC. The LOOP-OUT BNC must not be left open, if it is not connected to another DA-3GHD-8-PL-C1 backplane, it must be equipped with a good quality 75ohm termination. All OUT1 to OUT8 BNC’s provides non-inverted signals and can be used for all formats, included DVB-ASI. Unused outputs should be terminated with 75ohm.
Note: In an application with two or three distribution cards looped together, the source SDI­signal will travel through several BCN connector interconnects. It is therefore very important that those connectors are of good quality and specified for the bitrate used. Only new and fresh interconnection equipment should be used. This is especially important to 3G-SDI.
Page 11
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 11
See the following drawings for illustration of how the DA-3GHD-8-PL modules are looped together:
IN LOOP-OUT
OUT5
OUT6
OUT7
OUT8
OUT1
OUT2
OUT3
OUT4
Source cable
Termination
Total cable length = Source cable
Figure 7: Single module
IN LOOP-OUT
OUT5
OUT6
OUT7
OUT8
OUT1
OUT2
OUT3
OUT4
IN LOOP-OUT
OUT5
OUT6
OUT7
OUT8
OUT1
OUT2
OUT3
OUT4
Source cable
L1
Termination
Total cable length = Source cable + L1
Figure 8: Two modules looped
IN LOOP-OUT
OUT5
OUT6
OUT7
OUT8
OUT1
OUT2
OUT3
OUT4
IN LOOP-OUT
OUT5
OUT6
OUT7
OUT8
OUT1
OUT2
OUT3
OUT4
IN LOOP-OUT
OUT5
OUT6
OUT7
OUT8
OUT1
OUT2
OUT3
OUT4
Source cable
L1
L2
Termination
Total cable
length = Source cable + L1 + L2
Figure 9: Three modules looped
Page 12
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 12
5 Operation
The status of the module can be easily monitored visually by LED’s at the front of the module. The LED’s are visible through the front panel as shown in Figure 10.
Figure 10: Panel indicator overview for DA-3GHD-8-PL/DA-3GHD-8 (text not printed on the front
panel).
The functions of the different LED’s are described in Table 2.
Diode \ state
Red LED
Yellow LED
Green LED
No light
Status
Module is faulty
Module is OK Module has power
Module has no power
Signal
No input signal
EQ bypassed or muted
Input signal present Rate
Rate not detected
Recl. bypassed
Reclocker locked
Fourth LED not used
Table 2: LED status description
Status
Signal
Rate
Not used
Page 13
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 13
General environmental requirements for Nevion equipment
1.
The equipment will meet the guaranteed performance specification under the following environmental conditions:
-
Operating room temperature range:
0°C to 50°C
-
Operating relative humidity range:
<90% (non-condensing)
2.
The equipment will operate without damage under the following environmental conditions:
-
Temperature range:
-5°C to 55°C
-
Relative humidity range:
<95% (non-condensing)
Page 14
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 14
Product Warranty
The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Nevion, which are available on the company web site:
www.nevion.com
Page 15
DA-3GHD-8-PL / DA-3GHD-8 Rev. 3
nevion.com | 15
Appendix A Materials declaration and recycling information
A.1 Materials declaration
For product sold into China after 1st March 2007, we comply with the “Administrative Measure on the Control of Pollution by Electronic Information Products”. In the first stage of
this legislation, content of six hazardous materials has to be declared. The table below shows the required information.
組成名稱
Part Name
Toxic or hazardous substances and elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
六价铬
Hexavalent
Chromium
(Cr(VI))
多溴联苯
Polybrominated
biphenyls
(PBB)
多溴二苯醚
Polybrominated
diphenyl ethers
(PBDE)
DA-3GHD-8-PL DA-3GHD-8
O O O O O
O
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006.
This is indicated by the product marking:
A.2 Recycling information
Nevion provides assistance to customers and recyclers through our web site
http://www.nevion.com/. Please contact Nevions Customer Support for assistance with
recycling if this site does not show the information you require. Where it is not possible to return the product to Nevion or its agents for recycling, the
following general information may be of assistance:
Before attempting disassembly, ensure the product is completely disconnected from
power and signal connections.
All major parts are marked or labeled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices.
Page 16
Nevion HQ:
Nevion Europe, P.O. Box 1020, 3204 Sandefjord, Norway
Tel: +47 33 48 99 99 – Fax: +47 33 48 99 98 – www.nevion.com
EC Declaration of Conformity
MANUFACTURER
Nevion
AUTHORIZED REPRESENTATIVE (Established within the EEA)
Not applicable
MODEL NUMBER(S)
DA-3GHD-8-PL / DA-3GHD-8
DESCRIPTION
1x8 non-inverting 3GHD-SDI and ASI Distribution Amplifier with or without passive loop-through
DIRECTIVES this equipment complies with
Low voltage (EU Directive 2006/95/EC) EMC (EU Directive 2004/108/EC) RoHS (EU Directive 2002/95/EC) China RoHS4 WEEE (EU Directive 2002/96/EC) REACH
HARMONISED STANDARDS applied in order to verify compliance with Directive(s)
EN 55103-1:1996 EN 55103-2:1996 EN 60950-1:2006
TEST REPORTS ISSUED BY
Notified/Competent Body
Report no:
TECHNICAL CONSTRUCTION FILE NO
Not applicable
YEAR WHICH THE CE-MARK WAS AFFIXED
2012
TEST AUTHORIZED SIGNATORY
MANUFACTURER
AUTHORIZED REPRESENTATIVE (Established within EEA)
Date of Issue
2012-03-08
Place of Issue
Not applicable
Sandefjord, Norway
Name
Thomas Øhrbom
Position
VP of Business Support Systems, Nevion (authorized signature)
4
Administration on the Control of Pollution Caused by Electronic Information Products
Loading...