Nevion DA-3GHD-2x42x4 User Manual

Page 1
Nevion Europe
P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98
www.nevion.com
DA-3GHD-2x4
Multi Rate 3GHD-SDI Distribution Amplifier
User manual
Page 2
DA-3GHD-2x4 Rev. 0
nevion.com | 2
Nevion Support
Nevion Europe P.O. Box 1020
3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99
Nevion USA
1600 Emerson Avenue
Oxnard, CA 93033, USA
Toll free North America: (866) 515-0811
Outside North America: +1 (805) 247-8560
E-mail: support@nevion.com
See http://www.nevion.com/support/ for service hours for customer support globally.
Revision history
Current revision of this document is the uppermost in the table below.
Rev.
Repl.
Date
Sign
Change description
0 A 2011-01-31
MR
Initial version
Page 3
DA-3GHD-2x4 Rev. 0
nevion.com | 3
Contents
Revision history .......................................................................................................... 2
1 Product overview ..................................................................................................... 4
2 Specifications .......................................................................................................... 6
3 Configuration ........................................................................................................... 7
3.1 Configuration Examples................................................................................................... 8
4 Connections ............................................................................................................. 9
5 Operation ............................................................................................................... 11
General environmental requirements for Nevion equipment..................................... 13
Product Warranty ...................................................................................................... 14
Appendix A Materials declaration and recycling information..................................... 15
A.1 Materials declaration ......................................................................................................15
A.2 Recycling information .....................................................................................................15
EC Declaration of Conformity ................................................................................... 16
Page 4
DA-3GHD-2x4 Rev. 0
nevion.com | 4
1 Product overview
The Flashlink DA-3GHD-2x4 is a multi bit-rate distribution amplifier module providing high performance media distribution for various signal formats from 19.4Mbps up to 2970Mbps. The unit can be configured to do cable equalizing and reclocking of SMPTE 424M, SMPTE 292M and SMPTE 259M signal formats.
The two inputs typically provide automatic cable equalizing for up to 70 meters of cable (Belden 1694A at 2970Mbps) with a total of 6 or 8 reclocked outputs. The DA-3GHD-2x4 will detect HD and SD rates and automatically switch to the correct output slew-rate.
The reclockers support the bit-rates 270Mbps, 1483.5Mbps, 1485Mbps 2967Mbps and 2970Mbps. For other rates, the reclockers automatically switch to bypass mode, and the DA­3GHD-2x4 will work as a non-reclocking distribution amplifier with cable equalizers.
The DA-3GHD-2x4 also supports reclocking of DVB-ASI at 270Mbps, enabling all possible rates including empty transport streams with only K28.5 padding packets. 4 of the outputs are non-inverting and suitable for DVB-ASI.
The unit can be configured as a 1 x 8/6 distribution amplifier. Both input ports can be used. The included intelligent change-over feature gives the ability to change input based on input signal loss, loss of lock, EDH errors or a combination of the above.
There is also included a passive bypass function (with backplane board C2 and C4) from both inputs to non-inverted outputs with less than 15 m loss of cable length (enables full redundancy in case of mains failure).
The DA-3GHD-2x4 is designed for all distribution purposes in studio, duplication and broadcast applications.
The DA-3GHD-2x4 main board can be combined with 4 different backplane boards giving functions as follows:
Table 1. Product overview.
Please observe that –G versions cannot be used with N-Box, Flashlink one module desktop box, due to mechanical issues.
Product
Type of backplane board
# Outputs
GPI I/O
Relay (passive loop-through)
19240 DA-3GHD-2x4
Version C1
8
No
No
19241 DA-3GHD-2x4-PB
Version C2
8
No
Yes
19242 DA-3GHD-2x3-G
Version C3
6
Yes
No
19243 DA-3GHD-2x3-PB-G
Version C4
6
Yes
Yes
Page 5
DA-3GHD-2x4 Rev. 0
nevion.com | 5
Figure 1. DA-3GHD-2x4 block diagram
Page 6
DA-3GHD-2x4 Rev. 0
nevion.com | 6
2 Specifications
Electrical Outputs
Connectors
75 Ohm BNC
Output Return loss
- < -15dB, 5MHz -1.5GHz
- < -10dB, 1.5GHz - 3GHz
Output signal level
800mV +/- 10%
Output signal rise / fall time 20% - 80%
- SD limit: [0.4ns – 1.5ns]; <0.5ns rise/fall var.
- HD limit: < 270ps, <100ps rise/fall var.
- 3G HD limit: <135ps, <50ps rise/fall var.
Amplitude overshoot
<10%
Polarity
- Output O1A, O1B, O2A and O2B: Non inverting electrical
- Remaining outputs: inverting electrical
Output timing jitter
- SD: <0.2 UI
- HD: <1 UI
- 3G HD: <1UI
Output alignment jitter
- SD: <0.15 UI
- HD: <0.15 UI
- 3G HD: <0.2UI
Electrical Inputs
Connectors
75 Ohm BNC
Input Cable Eq. @270Mbps
>300m w/Belden 1694A, with BER < 10E-12
Input Cable Eq. @1485Mbps
>100m w/Belden 1694A, with BER < 10E-12
Input Cable Eq. @2970Mbps
>70m w/Belden 1694A, with BER < 10E-12
Input Return loss
- < -15dB, 5MHz -1.5GHz
- < -10dB, 1.5GHz - 3GHz
Jitter tolerance
- SD limit:
- 10Hz-1kHz: >1 UI
- 10kHz – 5MHz: >0.2 UI
- HD limit:
- 10Hz-100kHz: >1 UI
- 100kHz–10MHz: >0.2 UI
- 3G HD limit:
- 10Hz-100kHz: >2 UI
- 100kHz–10MHz: >0.3 UI
Features
Reclocking:
Automatic SD/ HD detection Automatic output slew rate adjustment according to SMPTE 259M and SMPTE 292M / SMPTE 424M
Supported clock rates:
270, 1483.5, 1485, 2967, 2970Mbps
Input equalizers:
Eq. bypass for non-video formats or low bit rates
Supported standards
SMPTE:
SMPTE 424M, SMPTE 292M, SMPTE 259M, SMPTE 305M, SMPTE 310M
DVB-ASI:
EN50083-9 (on non-inverting outputs)
General
DC power consumption:
+5V / < 4.5W
Page 7
DA-3GHD-2x4 Rev. 0
nevion.com | 7
3 Configuration
The DA-3GHD-2x4 supports a number of different formats. The correct configuration can either be set with a DIP switch or with the GYDA system controller. The layout of DA-3GHD­2x4 is shown in the drawing below with the DIP switch to the upper left position.
Figure 2. DA-3GHD-2x4 module DIP switches
DIP switch configuration must be set according to the table below:
Switch #
Label
Function DIP=OFF
Function DIP=ON
Comment
1
CHO
Not used
2
IN1
Input 1 stby, 2 main
Input 1 main, 2 stby
Select main/standby
3
S/D
Single distributed output
Dual distributed output
Single or dual distribution amplifier
4
RUL
Not used
5
LTC
Not used
6
RCL
Reclocker Bypass
Reclocker ON
Reclocker mode
7
EQ
Cable equalizer Bypass (Loss of signal will not work on this mode)
Cable equalizer ON
Equalizer mode 8
OVR
Module controlled by Gyda system controller
Module controlled by DIP switches
Select GYDA config. mode
Table 2. DA-3GHD DIP switches
All DIP switches are off when pointing towards the release handle.
DIP-switch
Page 8
DA-3GHD-2x4 Rev. 0
nevion.com | 8
3.1 Configuration Examples
Typical configurations for DA-3GHD-2x4:
Figure 3. Distribution mode, Input 1 priority, Input 1 to all outputs, reclocker and equalizer on
Figure 4. Distribution mode, Input 2 priority, Input 1 to 4 outputs, Input 2 to 4 outputs, transparent mode without equalization and reclocking.
Page 9
DA-3GHD-2x4 Rev. 0
nevion.com | 9
4 Connections
The DA-3GHD-2x4 has four dedicated back planes: DA-3GHD-2x4-C1, - C2, - C3 and – C4. These modules are mounted at the rear of the sub-rack. The modules are shown in figure 7 to 10.
Figure 7. Overview of the DA-3GHD-2x4-C1 connector module
Figure 8. Overview of the DA-3GHD-2x4-C2 connector module
Page 10
DA-3GHD-2x4 Rev. 0
nevion.com | 10
Figure 9. Overview of the DA-3GHD-2x4-C3 connector module
Figure 10. Overview of the DA-3GHD-2x4-C4 connector module
The electrical input signals are connected to the IN1 and IN2 BNCs and the electrical outputs are connected to the O-- BNCs.
Please note that O1A, O1B, O2A and O2B have inverted signals. DVB-ASI cannot be used on these outputs.
Unused inputs and outputs should be terminated with 75 ohm to meet the specifications.
Page 11
DA-3GHD-2x4 Rev. 0
nevion.com | 11
5 Operation
The status of the module can be easily monitored visually by the LEDs at the front of the module. The LEDs are visible through the front panel as shown in Error! Reference source
not found. below.
Figure 11: Panel indicator overview for (Text not printed on the front panel).
The functions of the different LEDs are described in .
Diode \ state
Red LED
Yellow LED
Green LED
No light
Status
Module is faulty
Module is OK Module has power
Module has no power
LOL & LOS 1 (Input 1)
No Reclocker Lock & Loss Of Signal
No Reclocker lock & Signal present
Reclocker in lock & Signal present
LOL & LOS 2 (Input 2)
No Reclocker Lock & Loss Of Signal
No Reclocker lock & Signal present
Reclocker in lock & Signal present Main/Bypass
No stable input
Bypass selected
Main selected
Table 3: LED status description
Status
LOL & LOS 1
LOL & LOS 2
Main/Bypass
Page 12
DA-3GHD-2x4 Rev. 0
nevion.com | 12
GPI name
(setup1/
setup2)
Function
(setup1/ setup2)
Pin #
Mode
Direction
Electrical
Maximums
for GPI
outputs:
Max current:
100mA
Max voltage:
30V
Max power:
200mW
Status
General error status for the module.
Pin 1
Inverted Open Collector (open is alarm)
Output LOS
1
Loss of signal or lock at selected input
Pin 2
Open Collector
Output Input 1
Input 1 selected (IN1)
Pin 3
Open Collector
Output
Input 2
Input 2 selected (IN2)
Pin 4
Open Collector
Output
Reset
Reset selected input to main
Pin 5
TTL, 0V = active level
Input
Set
Set selected input to standby
Pin 6
TTL, 0V = active level
Input Not used
Pin 7
Ground
0 volt pin
Pin 8
0V.
Table 4 - Description of GPI interface
Figure 12. GPI Interface
Page 13
DA-3GHD-2x4 Rev. 0
nevion.com | 13
General environmental requirements for Nevion equipment
1.
The equipment will meet the guaranteed performance specification under the following environmental conditions:
-
Operating room temperature range:
0°C to 45°C
-
Operating relative humidity range:
<90% (non-condensing)
2.
The equipment will operate without damage under the following environmental conditions:
-
Temperature range:
-10°C to 55°C
-
Relative humidity range:
<95% (non-condensing)
Page 14
DA-3GHD-2x4 Rev. 0
nevion.com | 14
Product Warranty
The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Nevion, which are available on the company web site:
www.nevion.com
Page 15
DA-3GHD-2x4 Rev. 0
nevion.com | 15
Appendix A Materials declaration and recycling information
A.1 Materials declaration
For product sold into China after 1st March 2007, we comply with the “Administrative Measure on the Control of Pollution by Electronic Information Products”. In the first stage of
this legislation, content of six hazardous materials has to be declared. The table below shows the required information.
組成名稱
Part Name
Toxic or hazardous substances and elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
六价铬
Hexavalent
Chromium
(Cr(VI))
多溴联苯
Polybrominated
biphenyls
(PBB)
多溴二苯醚
Polybrominated
diphenyl ethers
(PBDE)
DA-3GHD-2x4
O O O O O
O
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006.
This is indicated by the product marking:
A.2 Recycling information
Nevion provides assistance to customers and recyclers through our web site
http://www.nevion.com/. Please contact Nevions Customer Support for assistance with
recycling if this site does not show the information you require. Where it is not possible to return the product to Nevion or its agents for recycling, the
following general information may be of assistance:
Before attempting disassembly, ensure the product is completely disconnected from
power and signal connections.
All major parts are marked or labeled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices.
Page 16
Nevion Europe
P.O. Box 1020, 3204 Sandefjord, Norway – Tel: +47 33 48 99 99 – Fax: +47 33 48 99 98
www.nevion.com
EC Declaration of Conformity
MANUFACTURER
Nevion Europe AS P.O. Box 1020, 3204 Sandefjord, Norway
AUTHORIZED REPRESENTATIVE (Established within the EEA)
Not applicable
MODEL NUMBER(S)
DA-3GHD-2x4
DESCRIPTION
Multi Rate 3GHD-SDI Distribution Amplifier
DIRECTIVES this equipment complies with
Low voltage (EU Directive 2006/95/EC) EMC (EU Directive 2004/108/EC) RoHS (EU Directive 2002/95/EC) China RoHS1 WEEE (EU Directive 2002/96/EC) REACH
HARMONISED STANDARDS applied in order to verify compliance with Directive(s)
EN 55103-1:2010 EN 55103-2:2010
TEST REPORTS ISSUED BY
Notified/Competent Body
Report no:
TECHNICAL CONSTRUCTION FILE NO
Not applicable
YEAR WHICH THE CE-MARK WAS AFFIXED
2011
TEST AUTHORIZED SIGNATORY
MANUFACTURER
AUTHORIZED REPRESENTATIVE (Established within EEA)
Date of Issue
2011-02-03
Place of Issue
Not applicable
Sandefjord, Norway
Name
Thomas Øhrbom
Position
QA Director, Nevion Europe (authorized signature)
1
Administration on the Control of Pollution Caused by Electronic Information Products
Loading...