All indicators will light on when the device is switched on
5
MENU key
6
LOCK key
Introduction
NetUP Streamer HDMI 8x is an all-in-one device, that integrates encoding, (MPEG-4/AVC H.264)
multiplexing and modulation functions in a 1U case. It is capable of converting 8 HDMI signals and 1
ASI input to 2 DVB-T RF outputs in the frequency range of 30~999MHz. It is also equipped with 2 ASI
ports and an IP port. The source signal may come from a satellite receiver, closed-circuit television
camera, etc. The device’s output can be received by DVB-T standard TVs or DVB-T STBs.
This device can be used for advertising or monitoring purposes in public places such as metro, market
halls, theatres, hotels, resorts, etc.
Appearance and illustration
Front panel:
1 LCD screen
Power
2 Indicators
3 UP/DOWN, LEFT/RIGHT keys
4 ENTER key
3
Page 4
NetUP Streamer HDMI 8x. User manual
Rear panel:
1
HDMI ports
2
RF test port
3
RF output port
4
ASI input port
5
ASI output ports
6
DATA port (for IP signal output)
7
NMS (Network management port)
8
Power switch
9
Fuse
10
Power socket
11
Grounding pole
4
Page 5
NetUP Streamer HDMI 8x. User manual
Encoding
MPEG-4 AVC/H.264
Resolution
1920×1080_60p,1920×1080_50p
Bitrate
0.8Mbps~19Mbps (each channel)
Rate control
VBR/CBR
GOP Structure
IBBP
Advanced Pretreatment
Deinterlacing, Noise reduction, Sharpening
Encoding
MPEG-1 Layer 2, HE-AAC V2, LC- AAC
Bitrate
64Kbps~384Kbps (each channel)
1 ASI input multiplexed with local 8 channels of TS
PID remapping (automatically or manually)
Accurate PCR adjusting
Generate PSI/SI table automatically
Standard
EN300744
FFT mode
2K, 8K
Bandwidth
6MHz, 7MHz, 8MHz
Constellation
QPSK, 16QAM, 64QAM
Guard Interval
1/4, 1/8, 1/16, 1/32
FEC
1/2, 2/3, 3/4, 5/6, 7/8
MER
≥42dB
RF frequency
30~960MHz, 1KHz step
RF output level
-30~ -10dbm (77~97 dbµV), 0.1db step
RF out
2×RF DVB-T out
2×ASI to mirror one RF output, BNC interface
Control
8×SPTS over UDP, RTP/RTSP, 1000Base-T Ethernet interface (unicast / multicast)
System
Other
parameters
5
Page 6
NetUP Streamer HDMI 8x. User manual
Installation guide
Device’s installation flow chart
Packing list
check
Installing
device
Before installing and connecting the device, carefully read the environment and
grounding requirements, as well as safety instructions for the sake of your safety and for
the safety of the device
Packing list check
Check items according to packing list. Normally it should include the following items:
• NetUP Streamer HDMI 8x
Connecting
grounding
wire and
power cord
Connecting
signal cable
Setting
parameter
Running
device
• Power Cord
• HDMI cable
• ASI cable
Safety instructions
• Before installing and connecting the device make sure that the device was not damaged during
delivery.
• Install the device in an appropriate place. The device is designed to work in a clean and dry room.
It must be operated and maintained free of dust.
• Before switching on the device make sure that it is adjusted to the mains voltage you intend to
use. Make sure that you keep within the specifications – AC 100V-220V±10%, 50/60Hz.
• Check that all the cables are connected properly. Connect cables only to a device that is turned
off.
6
Page 7
NetUP Streamer HDMI 8x. User manual
Item
Requirement
Room space
When installing a rack in the room, make sure the distance between two
Room floor
Electric isolation. Dust free. The volume resistivity of ground anti-static
Environment
5~40℃ (sustainable), 0~45℃ (short time).
Relative temperature
20%~80% (sustainable); 10%~90% (short time).
Pressure
86~105KPa
Door & window
Install rubber strip for sealing door-gaps and dual level glasses for windows.
Walls
Can be covered with wallpaper or dark paint.
Fire protection
Fire alarm system and extinguisher.
Power
The device requires AC 100V-220V±10%, 50/60Hz.
Environment requirement
rows of racks is 1.2~1.5m and the distance to the wall is at least 0.8m.
material: 1×107~1×1010 Ω. Grounding current limiting resistance: 1M (Floor
bearing should be greater than 450Kg/m2).
temperature
Installing air-conditioning is recommended.
Please carefully check before running.
Grounding requirement
• Connect the ground wire to the grounding hardware on the device. Ground resistance should be
no more than 1 Ω
Grounding is essential for device’s functionality, surge and electronic interference
protection
• Keep proper contact with the metal housing of the device
• Grounding wire must be made out of copper and as thick and short as possible
• Make sure the two ends of grounding wire conduct electricity and are not rusty
• It is prohibited to use any other devices as a part of grounding electric circuit
• All racks should be connected with a protective copper strip. Ground loops should be avoided
• Grounding wire’s contact area with the rack should be no less than 25mm
2
7
Page 8
NetUP Streamer HDMI 8x. User manual
MENU
Cancel unsaved changes, resets to previous settings and returns to the previous
ENTER
Select a menu item and activates a parameter for modifying, or confirms the
LEFT / RIGHT
Navigate through the menu and choose between the available options
LOCK
Lock or unlock the screen. After pressing the lock key, the system will ask if you
LCD screen feature description
NetUP Streamer HDMI 8x has the LCD screen and keys on its front panel. You can use them to control
and configure the device. Here is the description of keys’ functions:
menu
changes after modification
UP / DOWN
want to save the current changes. If you select “No”, the LCD will display the
current configuration state
Initializing and general settings
After powering on the device, it will take a few seconds to initialize the system, and then the LCD will
show the device’s name and multiplex bitrate or max modulating bitrate in the first row, while
channels’ respective input video resolution, frame rate and real-time encoding bitrate in the second row in turn. It shows as below:
The Output Settings menu contains nine submenus, eight items for each of the SPTS outputs and one
item for the ASI output:
Output 1
-----------------Output 8
ASI Output
Select one of the SPTS outputs and press ENTER to get access to the following settings:
Select the ASI output and press ENTER to get access to the following settings:
4 MUX Setting
The MUX Setting menu contains three submenus:
4.1 Encoder Mux
4.2 ASI
4.3 PID Remap
Select an item and press ENTER.
4.1 Encoder Mux
The Encoder Mux menu gives you access to the following settings:
RF 1 Program list
RF 2 Program list
11
Page 12
NetUP Streamer HDMI 8x. User manual
Item
Valid values
PID Remap
►Yes
Yes or No.
1) Press ENTER to open a list for editing.
2) Use UP / DOWN to select program that should be routed to the selected RF.
3) Use LEFT / RIGHT to select “Add” (add to list) or “Del” (remove from list).
4) Press ENTER to apply changes or press MENU to return to the program list.
4.2 ASI
The ASI menu gives you access to the following settings:
4.2.1 Program List
4.2.2 Parse Prog
4.3 PID Remap
5 Network Setting
The Network Setting menu contains two submenus:
5.1 NMS Interface
5.2 Data Interface
Select one of these items and press ENTER. Both of them give you access to the following settings:
5.1.1 IP Address
192.168.002.136
5.1.2 Subnet Mask
255.255.255.000
5.1.3 Default Gateway
192.168.002.001
5.1.4 MAC Address
201012345679
Use the web interface to modify MAC address
12
Page 13
NetUP Streamer HDMI 8x. User manual
6 Configuration Setting
The Configuration Setting menu gives access to following settings:
Save Config
►Yes
Restore Configuration
►Yes
Factory Set
►Yes
Select the Factory Set item and press ENTER toreset to factory settings
7 Version
Use the Version menu to check the current firmware versions:
7.1 SW Version
X.XX
7.2 HW Version
X.XX
13
Page 14
NetUP Streamer HDMI 8x. User manual
WEB NMS Operation
In addition to the buttons on the front panel, you can use the web interface to control NetUP
Streamer HDMI 8x.
Login
Connect a personal computer and the device with net cable, and use ping command to confirm they
are on the same network segment.
Make sure that the computer’s IP address is different from the device’s IP address;
otherwise, it would cause an IP conflict
The default IP address of NetUP Streamer HDMI 8x is 192.168.0.136. Thus, set the computer’s IP
address to 192.168.0.X, where X can be from 0 to 255, except 136. Open a web browser, enter the
device’s IP address in the browser address bar and press Enter. If the network is configured correctly,
you will see the login interface (Figure 1).
Enter username and password and click LOGIN to enter the web interface. Default username is
“admin”, default password is “admin”.
Figure-1
14
Page 15
NetUP Streamer HDMI 8x. User manual
Use this menu to navigate
States of the
input
Output TS indicator.
Status
After login, you will get the Status page which displays the current system status (Figure-2).
between the interface
pages
Figure-2
"Red" means error
HDMI inputs
and the ASI
15
Page 16
NetUP Streamer HDMI 8x. User manual
Set
Select a channel
See the channel’s input
status and bitrate
Confirm changes
Encoder
Open the Encoder page to set coding parameters for each channel (Figure-3).
parameters
resolution, encoding
Figure-3
16
Page 17
NetUP Streamer HDMI 8x. User manual
Operation
area
Parse the
ASI input
Output area
HDMI input
Input area
Select the output
Open a window to
MUX
Open the MUX page to set program multiplexing parameters (Figure-4).
program list
programs
programs
modify program
information
Figure-4
Operation area
update, expand or collapse program lists
enable or disable PID remapping
refresh an input or an output
move programs between the input and the output areas
modify program information
17
Page 18
NetUP Streamer HDMI 8x. User manual
Parameters that
Confirm changes
Program modification window
Select a program and click on Edit to modify program information (Figure-5).
can be changed
Figure-5
18
Page 19
NetUP Streamer HDMI 8x. User manual
Bandwidth
6 MHz, 7 MHz, 8 MHz
Constellation
QPSK, 16QAM, 64QAM
FFT
2K, 8K
Guard Interval
1/4, 1/8, 1/16, 1/32
Code Rate
1/2, 2/3, 3/4, 5/6, 7/8
RF1-2 Frequency
30…960 MHz
RF Level
-30,0…-10,0 dbm
Confirm changes
Modulator
Use the Modulator page (Figure-6) to configure the following parameters:
Figure-6
Output
Use the Output page to set up outputs. There is a separate tab for each type of signal: IP Out
Settings, DATA IP Settings, ASI Output.
19
Page 20
NetUP Streamer HDMI 8x. User manual
"Green" indicates that the
bitrate overflow
Press the
SPTS
Select one of the options; OFF,
output the corresponding MPTS
Confirm changes
IP Out Settings
Use the IP Out Settings tab to set up SPTS outputs (Figure-7).
output bitrate is normal.
"Red" indicates that the output
button to
adjust output
Figure-7
Output Set window:
UDP, RTP / RTSP.
Set OFF if you do not want to
20
Page 21
NetUP Streamer HDMI 8x. User manual
Confirm changes
Select the
Confirm changes
DATA IP Settings
Use the DATA IP Settings tab to set network parameters (Figure-8).
Figure-8
ASI Output
Use the ASI Output tab to select TS output from ASI (Figure-9).
program
Figure-9
21
Page 22
NetUP Streamer HDMI 8x. User manual
Select the channel
Confirm changes
Add a program descriptor to NIT
Network information
Virtual channel table
TS Config
Use the TS Config page contains the output TS, NIT and VCT settings for each of the output channels
(Figure-10).
Figure-10
table
22
Page 23
NetUP Streamer HDMI 8x. User manual
Confirm changes
Descriptor settings
System
Use the System page to save or restore the system configuration, return to the factory settings and
load the configuration file (Figure-11).
Figure-11
23
Page 24
NetUP Streamer HDMI 8x. User manual
Confirm changes
Confirm changes
Network
Use the Network page to edit networking parameters (Figure-12).
Figure-12
Password
Use the Password page to change current password and username (Figure-13).
Figure-13
24
Page 25
NetUP Streamer HDMI 8x. User manual
Troubleshooting
Check the following before troubleshooting:
•Whether the server room is well ventilated and hot air from the back panel of the device is
effectively removed?
• Does the supply voltage meet the power requirements of the device?
• Is the RF output level vary within the tolerant range?
• Are all cables connected correctly?
Turn off the device and unplug the power cord in the following cases:
• The power cord or socket is damaged.
• A liquid is splashed on the device.
• A short circuit has occurred.
• The device is in damp environment.
• The device suffered from physical damage.
• Longtime idle.
• After switching on and restoring to factory setting, device still cannot work properly.
• Maintenance needed.
Frequent on and off switching is prohibited; the interval between switching the device on
and off must be more than 10 seconds
25
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.