NetUP Streamer HDMI 8x User Manual

Page 1
NetUP Streamer HDMI 8x
User manual
1/7, Ulofa Palme str., Moscow, Russia
+7 (495)510-1025 | [email protected] | http://netup.tv
Page 2
NetUP Streamer HDMI 8x. User manual
Contents
Introduction ............................................................................ 3
Appearance and illustration ................................................................................................... 3
Specifications ......................................................................................................................... 5
Installation guide ..................................................................... 6
Device’s installation flow chart .............................................................................................. 6
Packing list check ................................................................................................................... 6
Safety instructions ................................................................................................................. 6
Environment requirement ..................................................................................................... 7
Grounding requirement ......................................................................................................... 7
LCD screen feature description ................................................ 8
Initializing and general settings ............................................................................................. 8
1 System Param ...................................................................................................................... 9
2 Modulator ......................................................................................................................... 10
3 Output Settings ................................................................................................................. 11
4 MUX Setting ...................................................................................................................... 11
5 Network Setting ................................................................................................................ 12
6 Configuration Setting ........................................................................................................ 13
7 Version .............................................................................................................................. 13
WEB NMS Operation ..............................................................14
Login ..................................................................................................................................... 14
Status.................................................................................................................................... 15
Encoder ................................................................................................................................ 16
MUX ...................................................................................................................................... 17
Modulator ............................................................................................................................ 19
Output .................................................................................................................................. 19
TS Config ............................................................................................................................... 22
System .................................................................................................................................. 23
Network ................................................................................................................................ 24
Password .............................................................................................................................. 24
Troubleshooting .........................................................................................25
2
Page 3
NetUP Streamer HDMI 8x. User manual
TS in – the input lock indicator
CH1-CH8 coding channels
All indicators will light on when the device is switched on
5
MENU key
6
LOCK key
Introduction
NetUP Streamer HDMI 8x is an all-in-one device, that integrates encoding, (MPEG-4/AVC H.264) multiplexing and modulation functions in a 1U case. It is capable of converting 8 HDMI signals and 1 ASI input to 2 DVB-T RF outputs in the frequency range of 30~999MHz. It is also equipped with 2 ASI ports and an IP port. The source signal may come from a satellite receiver, closed-circuit television camera, etc. The device’s output can be received by DVB-T standard TVs or DVB-T STBs. This device can be used for advertising or monitoring purposes in public places such as metro, market halls, theatres, hotels, resorts, etc.

Appearance and illustration

Front panel:
1 LCD screen
Power
2 Indicators
3 UP/DOWN, LEFT/RIGHT keys
4 ENTER key
3
Page 4
NetUP Streamer HDMI 8x. User manual
Rear panel:
1
HDMI ports
2
RF test port
3
RF output port
4
ASI input port
5
ASI output ports
6
DATA port (for IP signal output)
7
NMS (Network management port)
8
Power switch
9
Fuse
10
Power socket
11
Grounding pole
4
Page 5
NetUP Streamer HDMI 8x. User manual
Encoding
MPEG-4 AVC/H.264
Resolution
1920×1080_60p,1920×1080_50p
Bitrate
0.8Mbps~19Mbps (each channel)
Rate control
VBR/CBR
GOP Structure
IBBP
Advanced Pretreatment
Deinterlacing, Noise reduction, Sharpening
Encoding
MPEG-1 Layer 2, HE-AAC V2, LC- AAC
Bitrate
64Kbps~384Kbps (each channel)
1 ASI input multiplexed with local 8 channels of TS
PID remapping (automatically or manually)
Accurate PCR adjusting
Generate PSI/SI table automatically
Standard
EN300744
FFT mode
2K, 8K
Bandwidth
6MHz, 7MHz, 8MHz
Constellation
QPSK, 16QAM, 64QAM
Guard Interval
1/4, 1/8, 1/16, 1/32
FEC
1/2, 2/3, 3/4, 5/6, 7/8
MER
≥42dB
RF frequency
30~960MHz, 1KHz step
RF output level
-30~ -10dbm (77~97 dbµV), 0.1db step
RF out
2×RF DVB-T out
2×ASI to mirror one RF output, BNC interface Control
LCD/keyboard controls, web NMS support
Update
Ethernet software & hardware upgrade
Dimension (W×L×H)
482mm×328mm×44mm
Approx. weight
4kg
Temperature
0~45℃ (work); -20~80℃ (storage)
Power requirements
AC 100V-220V±10%, 50/60Hz
Power consumption
25W

Specifications

Input 8×HDMI and 1×ASI
Video
1920×1080_60i, 1920×1080_50i 1280×720_60p, 1280×720 _50p 720×576_50i, 720×480_60i
Audio
Multiplexing
Modulator
Output
Sample rate 48KHz
8×SPTS over UDP, RTP/RTSP, 1000Base-T Ethernet interface (unicast / multicast)
System
Other parameters
5
Page 6
NetUP Streamer HDMI 8x. User manual
Installation guide

Device’s installation flow chart

Packing list check

Installing device
Before installing and connecting the device, carefully read the environment and grounding requirements, as well as safety instructions for the sake of your safety and for the safety of the device
Packing list check
Check items according to packing list. Normally it should include the following items:
• NetUP Streamer HDMI 8x
Connecting grounding wire and power cord
Connecting signal cable
Setting parameter
Running device
• Power Cord
• HDMI cable
• ASI cable

Safety instructions

• Before installing and connecting the device make sure that the device was not damaged during
delivery.
• Install the device in an appropriate place. The device is designed to work in a clean and dry room.
It must be operated and maintained free of dust.
• Before switching on the device make sure that it is adjusted to the mains voltage you intend to
use. Make sure that you keep within the specifications – AC 100V-220V±10%, 50/60Hz.
• Check that all the cables are connected properly. Connect cables only to a device that is turned
off.
6
Page 7
NetUP Streamer HDMI 8x. User manual
Item
Requirement
Room space
When installing a rack in the room, make sure the distance between two
Room floor
Electric isolation. Dust free. The volume resistivity of ground anti-static
Environment
5~40℃ (sustainable), 0~45℃ (short time). Relative temperature
20%~80% (sustainable); 10%~90% (short time).
Pressure
86~105KPa
Door & window
Install rubber strip for sealing door-gaps and dual level glasses for windows.
Walls
Can be covered with wallpaper or dark paint.
Fire protection
Fire alarm system and extinguisher.
Power
The device requires AC 100V-220V±10%, 50/60Hz.

Environment requirement

rows of racks is 1.2~1.5m and the distance to the wall is at least 0.8m.
material: 1×107~1×1010 Ω. Grounding current limiting resistance: 1M (Floor bearing should be greater than 450Kg/m2).
temperature
Installing air-conditioning is recommended.
Please carefully check before running.

Grounding requirement

• Connect the ground wire to the grounding hardware on the device. Ground resistance should be
no more than 1 Ω
Grounding is essential for device’s functionality, surge and electronic interference
protection
• Keep proper contact with the metal housing of the device
• Grounding wire must be made out of copper and as thick and short as possible
• Make sure the two ends of grounding wire conduct electricity and are not rusty
• It is prohibited to use any other devices as a part of grounding electric circuit
• All racks should be connected with a protective copper strip. Ground loops should be avoided
• Grounding wire’s contact area with the rack should be no less than 25mm
2
7
Page 8
NetUP Streamer HDMI 8x. User manual
MENU
Cancel unsaved changes, resets to previous settings and returns to the previous
ENTER
Select a menu item and activates a parameter for modifying, or confirms the
LEFT / RIGHT
Navigate through the menu and choose between the available options
LOCK
Lock or unlock the screen. After pressing the lock key, the system will ask if you
LCD screen feature description
NetUP Streamer HDMI 8x has the LCD screen and keys on its front panel. You can use them to control and configure the device. Here is the description of keys’ functions:
menu
changes after modification
UP / DOWN
want to save the current changes. If you select “No”, the LCD will display the current configuration state

Initializing and general settings

After powering on the device, it will take a few seconds to initialize the system, and then the LCD will
show the device’s name and multiplex bitrate or max modulating bitrate in the first row, while channels’ respective input video resolution, frame rate and real-time encoding bitrate in the second row in turn. It shows as below:
Encoder Modulator 12.4/32.5Mbps 1 1080I 50 11.356M 2 1080I 50 11.356M
Press LOCK to enter the main menu and set the input and output parameters. The LCD will display the following pages:
1 System Param 2 Modulator 3 Output Setting 4 Mux Setting 5 Network Setting 6 Config Setting 7 Version
Use UP / Down to move through the list. The arrow icon (►) indicates which item has
been selected. Press ENTER to get to the submenu
8
Page 9
NetUP Streamer HDMI 8x. User manual
Item
Valid values
1.1 Bitrate (Mbps)
08.000
range from 0.8 to 19 Mbps
1.2 Bitrate Mode
CBR – Constant Bit Rate;
1.3 Profile [1] HIGH
HIGH or MAIN
1.4 Level [1] 1.2
range from 1.2 to 10

1 System Param

The System Param menu contains eight submenus, one for each of the eight encoding channels:
1.1 Channel 1
------------------
1.8 Channel 8
Select a channel and press ENTER to get to the submenu:
1 Video Param 2 Audio Param 3 Prg info
Select an item and press ENTER again.

1 Video Param

The Video Param menu gives you access to the following settings:
[1] CBR
VBR – Variable Bit Rate
Parameter’s current value is displayed under its name
1) Press ENTER to start editing.
2) Use UP / DOWN to select one of the possible values for the parameter. If you need to
enter a numeric value, first use LEFT / RIGHT to move the cursor to the desired position, and then set the value using the UP / DOWN buttons.
3) Press ENTER to apply changes or press MENU to return to the parameter list.
9
Page 10
NetUP Streamer HDMI 8x. User manual
Item
Valid values
2.1 Audio Bitrate [1] 64 Kbps
range from 64 to 384 Kbps
2.2 Audio Format
MPEG1 Layer II, LC-AAC and HE-AAC
Item
Valid values
3.1 Program Number 0x0101
integer
Item
Valid values
Bandwidth
6М, 7М and 8М
Constellation
QPSK, 16QAM or 64QAM
FFT
2К or 8К
Guard Interval
1/4, 1/8, 1/16, 1/32
Code rate
1/2, 2/3, 3/4, 5/6, 7/8
RF Frequency 1/2
range from 30 to 90 MHz with 1K step
RF level
range from -30 to -10 dbm (77~97dbµV) with 0.1db step
RF On 1/2
Off or On

2 Audio Param

The Audio Param menu gives you access to the following settings:
[1] MPEG1-Layer II

3 Prg info

The Prg info menu gives you access to the following settings:

2 Modulator

The Modulator menu gives you access to the following settings:
[1] 6M
[1] QPSK
[1] 2К
[1] 1/4
[1] 1/2
750.00MHz
-10.0 dbm
►Off
10
Page 11
NetUP Streamer HDMI 8x. User manual
Item
Valid values
1 Output Enable [1] OFF
UDP, RTP/RTSP or Off (disable an output).
2 Destination IP Address
224.002.002.002
IP address
3 Destination Port 1002
port
4 Filter Null Packet YES
YES or NO
5 TSID and ONID
TSID (Trans Stream ID); ONID (Original Network ID)
Item
Valid values
1 ASI output
[1] RF 1
RF 1 or RF 2

3 Output Settings

The Output Settings menu contains nine submenus, eight items for each of the SPTS outputs and one item for the ASI output:
Output 1
-----------------­Output 8 ASI Output
Select one of the SPTS outputs and press ENTER to get access to the following settings:
Select the ASI output and press ENTER to get access to the following settings:

4 MUX Setting

The MUX Setting menu contains three submenus:

4.1 Encoder Mux

4.2 ASI
4.3 PID Remap
Select an item and press ENTER.
4.1 Encoder Mux
The Encoder Mux menu gives you access to the following settings:
RF 1 Program list RF 2 Program list
11
Page 12
NetUP Streamer HDMI 8x. User manual
Item
Valid values
PID Remap
►Yes
Yes or No.
1) Press ENTER to open a list for editing.
2) Use UP / DOWN to select program that should be routed to the selected RF.
3) Use LEFT / RIGHT to select “Add” (add to list) or “Del” (remove from list).
4) Press ENTER to apply changes or press MENU to return to the program list.

4.2 ASI

The ASI menu gives you access to the following settings:
4.2.1 Program List
4.2.2 Parse Prog

4.3 PID Remap

5 Network Setting

The Network Setting menu contains two submenus:
5.1 NMS Interface
5.2 Data Interface
Select one of these items and press ENTER. Both of them give you access to the following settings:
5.1.1 IP Address
192.168.002.136
5.1.2 Subnet Mask
255.255.255.000
5.1.3 Default Gateway
192.168.002.001
5.1.4 MAC Address 201012345679
Use the web interface to modify MAC address
12
Page 13
NetUP Streamer HDMI 8x. User manual

6 Configuration Setting

The Configuration Setting menu gives access to following settings:
Save Config
►Yes
Restore Configuration
►Yes
Factory Set
►Yes
Select the Factory Set item and press ENTER to reset to factory settings

7 Version

Use the Version menu to check the current firmware versions:
7.1 SW Version X.XX
7.2 HW Version X.XX
13
Page 14
NetUP Streamer HDMI 8x. User manual
WEB NMS Operation
In addition to the buttons on the front panel, you can use the web interface to control NetUP Streamer HDMI 8x.

Login

Connect a personal computer and the device with net cable, and use ping command to confirm they are on the same network segment.
Make sure that the computer’s IP address is different from the device’s IP address;
otherwise, it would cause an IP conflict
The default IP address of NetUP Streamer HDMI 8x is 192.168.0.136. Thus, set the computer’s IP address to 192.168.0.X, where X can be from 0 to 255, except 136. Open a web browser, enter the device’s IP address in the browser address bar and press Enter. If the network is configured correctly, you will see the login interface (Figure 1). Enter username and password and click LOGIN to enter the web interface. Default username is “admin”, default password is “admin”.
Figure-1
14
Page 15
NetUP Streamer HDMI 8x. User manual
Use this menu to navigate
States of the
input
Output TS indicator.

Status

After login, you will get the Status page which displays the current system status (Figure-2).
between the interface pages
Figure-2
"Red" means error
HDMI inputs and the ASI
15
Page 16
NetUP Streamer HDMI 8x. User manual
Set Select a channel
See the channel’s input
status and bitrate
Confirm changes

Encoder

Open the Encoder page to set coding parameters for each channel (Figure-3).
parameters
resolution, encoding
Figure-3
16
Page 17
NetUP Streamer HDMI 8x. User manual

Operation area

Parse the
ASI input Output area
HDMI input Input area
Select the output
Open a window to
MUX
Open the MUX page to set program multiplexing parameters (Figure-4).
program list
programs
programs
modify program information
Figure-4
Operation area
update, expand or collapse program lists
enable or disable PID remapping
refresh an input or an output
move programs between the input and the output areas
modify program information
17
Page 18
NetUP Streamer HDMI 8x. User manual
Parameters that Confirm changes

Program modification window

Select a program and click on Edit to modify program information (Figure-5).
can be changed
Figure-5
18
Page 19
NetUP Streamer HDMI 8x. User manual
Bandwidth
6 MHz, 7 MHz, 8 MHz
Constellation
QPSK, 16QAM, 64QAM
FFT
2K, 8K
Guard Interval
1/4, 1/8, 1/16, 1/32
Code Rate
1/2, 2/3, 3/4, 5/6, 7/8
RF1-2 Frequency
30…960 MHz
RF Level
-30,0…-10,0 dbm
Confirm changes

Modulator

Use the Modulator page (Figure-6) to configure the following parameters:
Figure-6

Output

Use the Output page to set up outputs. There is a separate tab for each type of signal: IP Out Settings, DATA IP Settings, ASI Output.
19
Page 20
NetUP Streamer HDMI 8x. User manual
"Green" indicates that the
bitrate overflow
Press the
SPTS
Select one of the options; OFF,
output the corresponding MPTS
Confirm changes

IP Out Settings

Use the IP Out Settings tab to set up SPTS outputs (Figure-7).
output bitrate is normal.
"Red" indicates that the output
button to adjust output
Figure-7
Output Set window:
UDP, RTP / RTSP. Set OFF if you do not want to
20
Page 21
NetUP Streamer HDMI 8x. User manual
Confirm changes
Select the Confirm changes

DATA IP Settings

Use the DATA IP Settings tab to set network parameters (Figure-8).
Figure-8

ASI Output

Use the ASI Output tab to select TS output from ASI (Figure-9).
program
Figure-9
21
Page 22
NetUP Streamer HDMI 8x. User manual
Select the channel
Confirm changes
Add a program descriptor to NIT
Network information Virtual channel table

TS Config

Use the TS Config page contains the output TS, NIT and VCT settings for each of the output channels (Figure-10).
Figure-10
table
22
Page 23
NetUP Streamer HDMI 8x. User manual
Confirm changes
Descriptor settings

System

Use the System page to save or restore the system configuration, return to the factory settings and load the configuration file (Figure-11).
Figure-11
23
Page 24
NetUP Streamer HDMI 8x. User manual
Confirm changes
Confirm changes

Network

Use the Network page to edit networking parameters (Figure-12).
Figure-12

Password

Use the Password page to change current password and username (Figure-13).
Figure-13
24
Page 25
NetUP Streamer HDMI 8x. User manual

Troubleshooting

Check the following before troubleshooting:
• Whether the server room is well ventilated and hot air from the back panel of the device is
effectively removed?
• Does the supply voltage meet the power requirements of the device?
• Is the RF output level vary within the tolerant range?
• Are all cables connected correctly?
Turn off the device and unplug the power cord in the following cases:
• The power cord or socket is damaged.
• A liquid is splashed on the device.
• A short circuit has occurred.
• The device is in damp environment.
• The device suffered from physical damage.
• Longtime idle.
• After switching on and restoring to factory setting, device still cannot work properly.
• Maintenance needed.
Frequent on and off switching is prohibited; the interval between switching the device on
and off must be more than 10 seconds
25
Loading...