VP
1004 ISO
Reader
Multiplexer
Quick start
The Velos VP
installed in a V-box. A VP
Inputs / Outputs / Antennas
- 8
antennas,
- 2
outputs available to act
1004 is a Velos component t
1004 is connected to the Velos CAN-bus and controlled by a
auto scanning one by one (max 10x VP1004 per VP
ivate e.g. lights and 2 inputs for reading e.g.
Po
wer
Supply
VP2001
max 3m
V
P1004
hat is used to identify animals. The VP
8001)
switches
V
P8001
To PC (LAN ethernet)
1004 must be
V
P1004
VP8001 (
VPU
).
V
P1004
Next VP1004
Next VP1004
FCC ID: CGDVELOS5 and IC: 1444A-VELOS5
Compliance statement (pa
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference receive
Déclaration Conformité
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis aux deux
conditions suivantes:
(1) cet appareil ne doit causer au
(2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas vou
de cet appareil.
rt15.19)
d, including interference that may cause undesired operation.
cune interférence, et
V
P1004
lu
Warning (part15.21)
Changes or modifications not expressly approved by party responsibl
the equipment.
This in particular is applicable for the antenna which can be delivered with the VP4001 System.
VP
1004- ISO
Reader Multiplexer
-
Quick start
e for compliance could void the user s authority to operate
9-
2011 Doc.part.
no. 5277434 45
.01
B 1/ 4

V
P8001 (1)
V
P8001 (2)
Connections
Velos cable
black
red
VP1004
OUT
blue white
blue
VP1004
orange white
red
Details VP
Vin
CAN
SYNC
I/O 1 ..
ANTENNA
F SYNC
2
blue white
blue
black
Velos cable IN
1004 inputs and outputs
FI/F
C
C
+
-
~
~
+
O
+
-
Input voltage 24 VDC, +20% -20%
Minus
CAN high (cable twisted pair with CL)
CAN low (cable twisted pair with CH)
Shielding of CAN-bus cable
Synchronisation
See above
Output max 400mA
Output max 400mA
Minus for
Input
I
O
Antenna (core)
Antenn
Frequency synchronisation FI=in FO=out
orange white
(no plus or minus, cable must be twisted pair)
/ 1.7A input
output (O
a (shield of coax cable)
) and minus input (I)
VP
1004- ISO
Reader Multiplexer
-
Quick start
9-
2011 Doc.part.
no. 5277434 45
.01
B 2/ 4

Details Velos cable
Red (+)
Black (
-)
Power
1,5 mm
2
Blue (C
Blue/white (C
Shield
Part No. 7705310
Antennas
A VP1004 has an automatic tuning module. The status is shown with LED indicators.
Only V-sense antennas types can be used. Not all types are compati
use.
Display menu
DISPLAY ADDRESS
Shows the actual address
SET ADDRESS
Change the address
ANTENNA POWER
Min/max 10 / 99. Normally set to 99. Possible to set a lower value.
Orange (Sync)
Orange/white (Sync)
Shield
h)
l)
display
Communication
0,34 mm
Twisted pair shielded
HF Synchronisation
0,34 mm
Twisted pair shielded
ble, check compatibility before
2
2
push button
ANTENNA SENSITIVITY SQUELCH
Min/max 9 / 0. Normally set to 0. Poss
SIGNAL LEVEL FDX
Shows signal level measured by the FDX receiver
SIGNAL LEVEL HDX
Shows signal level measured by the HDX receiver
TEST IDENTIFICATION
Shows last 2 digits of a tag number
DISPLAY ERROR
Shows error code
TEST OUTPUT
L1 L5
TEST INPUT
I1 i5
SETTINGS TO DEFAULT
All HF settings back to factory settings (enter 99)
ible to set a lower value.
VP
1004- ISO
Press button until blinking
Press button short
Reader Multiplexer
-
Quick start
9-
To leave menu:
press button until display is empty
2011 Doc.part.
no. 5277434 45
.01
B 3/ 4

LED indicators
POWER
STATUS
Display
V in
V out
LAST
O1 .. O
I1 .. I
ID
2
2
Green on
off
on
off
Blue
Slow breathing
Fast blinkin
Address indicated
Green on
off
Orange
Orange blinking
Red
Green on
off
Orange blinking
Red blinking
Green on
off
VOrange blinking
Red
Red blinking
Green on
off
Red blinking
Green on
off
Green one by one
Green on
Red on
g
V-
Power on
No power
Operating ok
Downloading or error during download
No communication
Communication status ok
Input power applied
No power
Low power, lower then 20V
Wrong CAN-bus connection, Vin and Vout swapped
Error, plus and minus swapped
Output power
No power
Low power
Error, plus and minus swapped
pack is last one on the CAN-bus
pack is not last one on the CAN-bus
CAN-bus error and last V-pack on CAN-bus
CAN-bus error
CAN-bus warning / wrong connected
Output on
Output off
Output error / ove
Input contact open
Input contact closed
Antenna ok
Antenna ok and tag identified
Antenna
rload
error / not connected /
not tuned correctly
Dimensions
CAN
Power
Software
Inputs
Outputs
Antennas
Detection distance
Synchronization
Environment
IP class
Always use a NEDAP power supply. The Nedap guarantee
indicated in
For more detailed information contact your local Nedap supplier or check the internet site.
This information is furnished for guidance, and with no guarantee as to its accura
licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specificatio
availability of goods mentioned in it are subject to change without notice; i
part, without the written consent of the publisher.
© Nedap N.V., AGRI P.O. Box 104 NL-7140 AC GROENLO The Netherlands
VP
1004- ISO
this manual. I
Reader Multiplexer
143 x 120 x 68 mm LxWxH (excluding mounting rail) Weight: ± 360 gr
CAN-bus communication
Input voltage 25 VDC, +20% -20%
Min power consumption 300 mA with antenna switched on
Protected against reverse connection power supply
Downloadable by the CAN network
Reading inputs, analog (0-40V) and digital. Suitable for NPN and PNP sensors.
Max. 0.4 Amp by current limiter, short-circuiting protected
800 µH. Different types possible.
Varies per antenna
Synchronization according to ISO 11785 / 24631
Temperature: Operating: -10
Relative humidity: 10
IP 30. When installed in V-box IP 65
nstall data cables at a safe distance from (high) powered cables
-
Quick start
9-
125 kBit
93% non condensing
55 °C, Storage: -25
-regulations are only valid when is installed as
-6
70 °C
(cover and cables installed correctly !)
cy or completeness; its publication conveys no
t is not to be reproduced in any way, in whole or in
2011 Doc.part.
no. 5277434 45
.01
ns and
B 4/ 4