Nedap N V VELOS5 User Manual

Page 1
Antenna 1
-
8
Antenna 17
-
24
Antenna 9
-
16
Antenna 25
-
32
VP
1004 ISO
Reader
Multiplexer
Quick start
The Velos VP installed in a V-box. A VP
Inputs / Outputs / Antennas
- 8
antennas,
- 2
outputs available to act
1004 is a Velos component t
1004 is connected to the Velos CAN-bus and controlled by a
auto scanning one by one (max 10x VP1004 per VP
ivate e.g. lights and 2 inputs for reading e.g.
Po
wer
Supply
VP2001
max 3m
V
P1004
hat is used to identify animals. The VP
8001) switches
V
P8001
To PC (LAN ethernet)
1004 must be
V
P1004
VP8001 (
VPU
).
V
P1004
Next VP1004
Next VP1004
FCC ID: CGDVELOS5 and IC: 1444A-VELOS5
Compliance statement (pa
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference receive
Déclaration Conformité
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer au (2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas vou de cet appareil.
rt15.19)
d, including interference that may cause undesired operation.
cune interférence, et
V
P1004
lu
Warning (part15.21)
Changes or modifications not expressly approved by party responsibl the equipment. This in particular is applicable for the antenna which can be delivered with the VP4001 System.
VP
1004- ISO
Reader Multiplexer
Quick start
e for compliance could void the user s authority to operate
9-
2011 Doc.part.
no. 5277434 45
.01
B 1/ 4
Page 2
H
L
VP1004
VP1004
LAN
o
range
(
to next VP1004)
antenna
o
range
Velos cable
Lmax = 80m Max =
5
x VP1004
Velos cable Lmax = 80m M
ax = 5x VP1004
V
P8001 (1)
V
P8001 (2)
Connections
Velos cable
black
red
VP1004
OUT
blue white
blue
VP1004
orange white
red
Details VP
Vin CAN
SYNC I/O 1 ..
ANTENNA F SYNC
2
blue white
blue
black
Velos cable IN
1004 inputs and outputs
FI/F
C C
+
-
~ ~ +
O
­+
-
Input voltage 24 VDC, +20% -20% Minus CAN high (cable twisted pair with CL) CAN low (cable twisted pair with CH) Shielding of CAN-bus cable Synchronisation See above Output max 400mA Output max 400mA Minus for Input
I
O
Antenna (core) Antenn Frequency synchronisation FI=in FO=out
orange white
(no plus or minus, cable must be twisted pair)
/ 1.7A input
output (O
a (shield of coax cable)
) and minus input (I)
VP
1004- ISO
Reader Multiplexer
Quick start
9-
2011 Doc.part.
no. 5277434 45
.01
B 2/ 4
Page 3
Details Velos cable
Red (+) Black (
-)
Power
1,5 mm
2
Blue (C Blue/white (C Shield
Part No. 7705310
Antennas
A VP1004 has an automatic tuning module. The status is shown with LED indicators. Only V-sense antennas types can be used. Not all types are compati use.
Display menu
DISPLAY ADDRESS
Shows the actual address
SET ADDRESS
Change the address
ANTENNA POWER
Min/max 10 / 99. Normally set to 99. Possible to set a lower value.
Orange (Sync) Orange/white (Sync) Shield
h)
l)
display
Communication
0,34 mm Twisted pair shielded
HF Synchronisation
0,34 mm Twisted pair shielded
ble, check compatibility before
2
2
push button
ANTENNA SENSITIVITY SQUELCH
Min/max 9 / 0. Normally set to 0. Poss
SIGNAL LEVEL FDX
Shows signal level measured by the FDX receiver
SIGNAL LEVEL HDX
Shows signal level measured by the HDX receiver
TEST IDENTIFICATION
Shows last 2 digits of a tag number
DISPLAY ERROR
Shows error code
TEST OUTPUT
L1 L5
TEST INPUT
I1 i5
SETTINGS TO DEFAULT
All HF settings back to factory settings (enter 99)
ible to set a lower value.
VP
1004- ISO
Press button until blinking Press button short
Reader Multiplexer
Quick start
9-
To leave menu: press button until display is empty
2011 Doc.part.
no. 5277434 45
.01
B 3/ 4
Page 4
Specifications VP 1004
LED indicators
POWER STATUS
Display V in
V out
LAST
O1 .. O
I1 .. I ID
2
2
Green on off
on off
Blue Slow breathing Fast blinkin Address indicated
Green on off Orange Orange blinking Red Green on off Orange blinking Red blinking Green on off
V­Orange blinking Red Red blinking Green on off Red blinking Green on off Green one by one Green on Red on
g
V-
Power on No power
Operating ok Downloading or error during download No communication Communication status ok Input power applied No power Low power, lower then 20V Wrong CAN-bus connection, Vin and Vout swapped Error, plus and minus swapped Output power No power Low power Error, plus and minus swapped
pack is last one on the CAN-bus
pack is not last one on the CAN-bus CAN-bus error and last V-pack on CAN-bus CAN-bus error CAN-bus warning / wrong connected Output on Output off Output error / ove Input contact open Input contact closed Antenna ok Antenna ok and tag identified Antenna
rload
error / not connected /
not tuned correctly
Dimensions CAN Power
Software Inputs Outputs Antennas Detection distance Synchronization Environment
IP class Always use a NEDAP power supply. The Nedap guarantee
indicated in For more detailed information contact your local Nedap supplier or check the internet site.
This information is furnished for guidance, and with no guarantee as to its accura licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specificatio availability of goods mentioned in it are subject to change without notice; i part, without the written consent of the publisher.
© Nedap N.V., AGRI P.O. Box 104 NL-7140 AC GROENLO The Netherlands
VP
1004- ISO
this manual. I
Reader Multiplexer
143 x 120 x 68 mm LxWxH (excluding mounting rail) Weight: ± 360 gr CAN-bus communication Input voltage 25 VDC, +20% -20% Min power consumption 300 mA with antenna switched on Protected against reverse connection power supply Downloadable by the CAN network Reading inputs, analog (0-40V) and digital. Suitable for NPN and PNP sensors. Max. 0.4 Amp by current limiter, short-circuiting protected 800 µH. Different types possible. Varies per antenna Synchronization according to ISO 11785 / 24631 Temperature: Operating: -10
Relative humidity: 10
IP 30. When installed in V-box IP 65
nstall data cables at a safe distance from (high) powered cables
Quick start
9-
125 kBit
93% non condensing
55 °C, Storage: -25
-regulations are only valid when is installed as
-6 70 °C
(cover and cables installed correctly !)
cy or completeness; its publication conveys no
t is not to be reproduced in any way, in whole or in
2011 Doc.part.
no. 5277434 45
.01
ns and
B 4/ 4
Loading...