1x !D Gate 1x Coax cable 3m/10ft
!D Gate
dimensions
1668
1668mm / 5.7ft
10 (oorpart)
orientation in the shop
462mm / 18.2”
462
60(2x)
195,5 828,75
1024,25
1024.25mm / 3.4ft
828.75mm / 2.7ft 195.5mm / 7.7”
70mm / 2.8”
70
57mm / 2.2”
57
100mm / 3.9”
100
distance between antennas
recommended - 2.0m / 6.5ft
absolute max. - 2.2m / 7ft
Power inserter
AB
all antennas
AB
sales oor
in the same
direction.
AB
GROENLO - HOLLAND
description:
quick reference !D Gate
Copyright © by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the
prior written permission of NEDAP.
AB
AB
AB
stock room
AB
drw: CB 2013/06/13
chk:
doc. article no: 5278988
rev. : C.01
sheet: 45.01 of 1
drawing: T5278-988

01
remove covers
02
drilling holes
ø 13mm / ø 0.5”
Cleaning Hilti-hit Place nut
Hilti-hit not included
0403
4x
4
M10
3
Metal M10
2
Nylon M10
(included in
installation set)
150mm / 5.9”
90mm / 3.5”
300mm / 11.8”
13mm / 0.5”
60mm / 2.4”
1
05
Nut (not included in installationset)
Nut (not included in installationset)
Retainer ring (not included in installationset)
Retainer ring (not included in installationset)
Nylon Insulation ring
Nylon Insulation ring (included in installationset)
(included in installation set)
Iron
Reinforced Concrete
Always mount an antenna insulated to the floor or wall
Iron
Reinforced Concrete
Always mount an antenna insulated to the oor or wall

processing unit
C
D
E
F
10
7
2
1
8
11
12
9
3
4
5
6
G
H
power supply
Out
In
Power for Reader
network IN
USB host
network OUT
USB service port
1 Green Processing unit at output
2 Blue Blink No device at output or Lan- modem (in case of OST integration)
Blue Continuous Power inserter at output
3 Red Power error
Power supply 9561811. One needed for
every installed system. (not included)
Not compatible with IEEE 802.3a* standard
Recommended to place in switch-room
1 Yellow Heartbeat
2 Green Disk access
3
1 2
3 Green Firmware running
+
buzzer
-
!D Reader
previous
next
Led Blue Orange Red Green Green
-
Firmware running Error RFID active Power

no coax cable needed
coax cable 3m / 10ft
1m / 3ft
0.5m / 1.5ft
1m / 3ft
2m / 6ft 2m / 6ft
required label free zone
recommended label free zone
2x coax cable 3m / 10ft
1m / 3ft
1m / 3ft
0.5m / 1.5ft

01
2 1
coax cable
02
03
previous
coax-cable 3m/10ft
2
2
1
1
next
Minimum bending
radius = >60mm/2.4”
note:
use only cat5e ethernet cable or better,
with all 8 wires connected.(straight cable)
processing unit
network IN
OUT
IN
RJ45 connector to ethernet
outlet - customer network.
note:
use only cat5e ethernet cable or better,
with all 8 wires connected.(straight cable)
coax cable
processing unit
network IN
place covers
processing unit
network OUT
RJ45 connector to ethernet
outlet - customer network.
connect voltage supply
Note :
230V
110V
The start up of all the
processes takes
approximately 3 minutes.
use rmware conguration quick reference.

Model: !D Gate Region 2
FCC ID: CGDSTOREIDG IC: 1444A-STOREIDG
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Cet appareil se conforme aux normes RSS 210 exemptés de license du Industry Canada.
L’opération est soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interférence, et
(2) cet appareil doit accepter n’importe quelle interférence, y inclus interférence qui peut causer
une opération non pas voulu de cet appareil.
Les changements ou modications n’ayant pas été expressément approuvés par la partie
responsable de la conformité peuvent faire perdre à l’utilisateur l’autorisation de faire fonctionner le
matériel.
FCC and IC Radiation Exposure Statement:
This equipment complies with FCC and Canadian radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of
3.65 cm between the radiator and your body. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
Cet équipement est conforme a RSS-102 limites énoncées pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale
de 3.65 cm entre le radiateur et votre corps.
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de Classe B est conforme à la norme Canadienne ICES-003