p
Installation Manual
Senzafil Control Unit
1. Mounting Instructions
Nedap recommends to use the Nedap Light Controls Box to build-in the control unit. (Nedap p/n …………..)
2. Connections
Note: The control unit must never be installed in a metal power cabinet. This would im
ede wireless communication.
Use of error contact
+24Vdc
+24Vdc
O
Indicator
ON inputs
o e.g. PLC
1-10V DIM inputs
Details inputs and outputs
+24V* + +24Vdc / 2% power input Input current: 0.3Adc max
- gnd
RS232 Optional
CAN Optional
Group 1..8 ON ON/OFF Input Closed=ON Open=OFF Levels: <3.5Vdc OFF and >4.5Vdc ON DIM DIM Input (Source current: 1mA (for light sensors)) Via switch: Closed=50% Open=100% Via 10kΩ potmeter: 0kΩ=50% 10kΩ=100% Via 1-10V Light Sensor: 1V=50% 10V=100% Via 1-10V PLC/BMS: 1V=50% 10V=100% ERR Error Output Contact to gnd: 30V/2A max
* NOTE: Use isolated 24Vdc limited power supply with 2.5A max current. For US/Canada use a listed class 2 power
supply. (e.g. MAIN WELL type GS15E-6P1J)
Control Unit Senzafil Copyright © NEDAP Installation Manual
Page 2
2. Led indications
POWER
CRTL
RF
LAMP ERROR x
4. Specifications
Input Voltage
On Power on Off Power off Fast blinking Controlling lamps Regular blinking (1s) EEPROM error (RF LED also blinking) Off Control ready Irregular blinking Receiving RF packets Regular blinking (1s) EEPROM error (CTRL LED also blinking) Off Receiving no RF packets On Lamp driver fault group x (>threshold) Blinking Lamp fault group x Off No errors group x
24Vdc ±2%
Operating temperature
Safety
EMC
Dimensions (l x b x h) 145 x 120 x 65 mm
0 – 60°C
EN60950 / Design to meet UL60950-1
EN301489-1 / FCC47 part 15 and 18
FCC Declarations
Compliance statement (part 15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Warning (part 15.21)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20cm separation distance between the antenna and all persons.
Version: 1.0 Nedap P/N: 8015228
Control Unit Senzafil Copyright © NEDAP Installation Manual