NEC VT70 Series, VT80 Series, VT60 Series, NP610 Series, NP-M350X Series Service Manual Supplement

...
MODEL VT60 Series NP600 Series
VT70 Series NP610 Series VT80 Series NP-M350X Series VT90 Series NP-M420X Series NP3150 Series NP-M350XS Series NP3250 Series NP-P420X Series VT700 Series
VT770 Series NP905 Series
SERVICE MANUAL SUPPLEMENT
Better Service
Better Reputation
Better Profit
Optical alignment jig (optical axis alignment/polarizer alignment)
SAFETY CAUTION:
Before servicing this chassis, it is important that the service
technician read and follow the “Safety Precautions” and
“Product Safety Notice” in this Service Manual.
WARNING:
SHOCK HAZARD - Use an isolation transformer when servicing.
NEC DISPLAY SOLUTIONS, LTD.
SAFETY PRECAUTIONS
2-1
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This symbol warns the user that uninsulated voltage within th e u ni t may have sufficient magnitude to cause electric shock. Therefore, it is dangerous to make any kind of contact with any part inside of this unit.
This symbol aler ts th e u ser t hat i mportant literature conce rn in g t he operation and maintenance of this unit has been included. Therefore, it should be read carefully in order to avoid any problems.
ATTENTION
RISQUE D'ELECTROCUTION
NE PAS OUVRIR
MISE EN GARDE: A FI N DE REDUIRE LES RISQUES D' ELECTR OC UT IO N, NE
PAS DEPO SER LE C OUVE RCLE , IL N' Y A A UCU N E P I ECE UTILISABLE A L'INTERIEUR DE CET APPAREIL. NE CONFIER LES TRAVAUX D'ENTRETIEN QU'A UN PERSONNEL QUALIFIE.
Ce symbole a pour but de prévenir I' utilisateur de la présence d' une tension dangereuse, non isolée se trouvant à l' intérieur de l'
appareil. Elle est d' une intensité sufsante pour constituer un risque
d' électrocution. Eviter le contact avec les pièces à l' intérieur de cet appareil.
Ce symbole a pour but de prévenir l' utilisateur de la présence d' importantes instructions concernant l' entretien et le fonctionnement de
cet appareil. Par conséquent, elles doivent être lues attentivement an
d' éviter des problèmes.
WARNING
HEATSINK MAY BE ENERGIZED. TEST BEFORE TOUCHING.
Heat sink located on the power board, is electried.
mark is putted on the primary heat sink. Pay attention to this area.
2-2
SAFETY PRECAUTIONS
During servicing carefully observe the following.
1. OBSERVE ALL PRECAUTIONS
Items and locations that require special care during
serv-icing, such as the cabinet, chassis, and parts are labelled with individual safety instructions. Carefully comply with these instructions and all precautions in the instruction manual.
2. BE CAREFUL OF ELECTRIC SHOCK
The chassis carries an AC voltage. If you touch the chassis while it is still alive, you will get a severe shock. If you think the chassis is alive, use an isolating transformer o r gloves, or pul l out t he plug before replacing any parts.
3. USE SPECIFIED PARTS
The components hav e be en chosen for min imu m
ammability and for specic levels of resistance value
and with s tand v oltag e. Re p lacem e nt pa r ts mu st ma tch these orig ina l sp ecifica tio ns. Parts whose specifications are particularly vital to safe use and maintenance of the set are marked on the circuit diagrams and parts list. Substitution of these parts can be dangerous for you
and the customer, so use only specied parts.
4. REMOUNT ALL PARTS AND RECONNECT ALL WIRES AS ORIGINALLY INSTALLED
For safety, insula t i n g tape and tub e s are u s e d throughout, but some lift-off parts on the printed wiring
board require special attention.
All wires are positioned away from high-temperature and high-voltage parts, and, if removed for servicing, they m u s t be retu n e d precise l y to thei r o r iginal positions.
5. LAMP
Be very careful of the lamp because it generates high heat while it is used at high voltage. When replacing the bulb, make sure it is cool enough.
6. LENS
Do not l ook i n to th e len s dur i ng pr oject i on. This important to avoid damage to the eyes.
7. SERVICING
At the time of repair or inspection services, use an earth band (wrist band), without fail.
8. RUN A COMPLETE SAFETY CHECK AT THE COMPLETION OF SERVICING
Aft e r com p l e tion of serv i c i ng, co n firm th a t a l l screws, parts, and wiring, removed or disconnected for servicing, have b een returned to their o riginal positions. Also examine if the serviced sections and peripheral areas have suffered from any deterioration as a result of servicing. In addition, check insulation between external metallic parts and blades of wall­outlet plugs. This examina tion is indispensable in
conrming complete establishment of safety.
(Insulation check) Pull out a plug from a wall outlet to disconnect the connection cable. Then turn on the POWER switch. Use a 500V megger (Note 2) and confirm that the
insulation resistance is 1MΩ or more between each
terminal of the plug and exposed external metal (Note
1). If the measured value is below the specied level, then it is necessary to inspect and x the set.
(Note 1)
Exposed external metal....RGB input terminals, control
terminals, etc. (Note 2) If a 500V megger is not available for an unavoidable reason, then use a circuit tester or the like for inspection.
Loading...