NEC NP-M311W Quick Start Manual

Page 1
NEC Display Solutions of America, Inc.
M311W Installation Guide
Ceiling Mounted and Desktop Rev 1.0
Contents
Product Description, Lens Specs, Notes and Formulas Pg 1 Diagrams & Distance Charts Cabinet Dimensions Ceiling Mount Dimensions Input Panel and Control Codes
Product Description
Type: 3 panel LCD projector, Dimensions: 13.4” (W) x 3.9” (H) x 10.2” (D) M311W 0.59” p-Si TFT w/MLA Weight: 6.6 lbs Resolution: 1280 x 800
Fan Noise: M311W: 35 dB / 28dB @ 1 meter Brightness: M311W - 3100 Lumens
Power Consumption: M311W: 311W (max) BTU’s: M311W 1061.18 BTU/hour
Lens Specifications
Throw Ratio: 1.3 – 2.2:1 (for 100” diagonal) Focal Length: 17.5mm 29.0mm Offset Angle: M311W: 6.6° - 10.9° (for 100” diagonal) F/#: 1.7 - 2.1
Screen Sizes: 25” - 300” diagonal (16:10) Manual Focus/Manual Zoom
Notes
For screen sizes not indicated on the projection tables, use the formulas below.
If the figures on the tables do not match the results of formulas, use the figures in the table.
All calculations are based on a 4:3 aspect ratio.  Distances are in inches, for millimeters multiply by 25.4.  Distances may vary 5%.
Formulas
The Projection Formulas use the image width for calculation. For proper projection placement, determine the image width for the desired screen size. Use the Screen Formulas below to calculate all screen dimensions. Plug in the width for “W” in the Projection Formulas. Refer to the diagrams and charts for popular screen sizes on page 2:
Definitions: 16:10 Screen Formulas:
W = Image Width W = H x 16/10 H = Image Height (size) H = W x 10/16 B = Vertical distance between lens center and screen center Screen Diagonal = W x 18.868/4 C = Throw distance D = Vertical distance between lens center and screen top (screen bottom for desktop application)
Projection Formulas: B = 0.2578W C (wide) = 1.361W – 1.68 C (tele) = 2.26W – 1.68 D = -0.055W
α (wide) = tan¯¹ (B/C(wide)) α (tele) = tan¯¹ (B/C(tele))
Pg 2 Pg 3-4 Pg 5 Pg 6
www.necdisplay.com M311W Page 1 of 6
Page 2
NEC Display Solutions of America, Inc.
M311W Installation Guide
Ceiling Mounted and Desktop Rev 1.0
Diagrams and Distance Charts
The following shows the proper relative positions of the projector and screen. Refer to the table to determine the position of installation. Distances are in inches. For millimeters multiply by 25.4.
Ceiling Mounted
4.56"
5.17"
Lens Offset From Mount Pipe
2.79
Desktop
2.22"
Distance Chart for popular 16:10 screens
Note:
For screen sizes not indicated on the projection
tables, use the formulas on page 1.
www.necdisplay.com M311W Page 2 of 6
Screen Size (16:10)
Diagonal Width(W) Height (H)
inches inches inches inches
57 48 30 12 64 - 107 11.0 - 6.6
66 56 35 14 75 - 125 11.0 - 6.6
68 58 36 15 77 - 128 11.0 - 6.6
75 64 40 16 85 - 143 10.9 - 6.6
79 67 42 17 90 - 150 10.9 - 6.6
85 72 45 19 96 - 161 10.9 - 6.6
92 78 49 20 105 - 176 10.9 - 6.6
98 83 52 21 112 - 186 10.9 - 6.6
102 86 54 22 116 - 194 10.9 - 6.6
111 94 59 24 127 - 212 10.9 - 6.6
113 96 60 25 129 - 215 10.9 - 6.6
123 104 65 27 140 - 233 10.9 - 6.6
125 106 66 27 142 - 237 10.8 - 6.6
147 125 78 32 168 - 280 10.8 - 6.5
149 126 79 33 170 - 284 10.8 - 6.5
213 181 113 47 244 - 407 10.8 - 6.5
255 216 135 56 292 - 486 10.8 - 6.5
C
Throw Distance
C
Throw Distance
B
C
w ide - tele
inches
D
inches
-3
-3
-3
-4
-4
-4
-4
-5
-5
-5
-5
-6
-6
-7
-7
-10
-12
Screen Top
D
Lens Ctr
B
Screen Ctr
Screen Ctr
B
Lens Ctr
D
Screen Bottom
α
w ide - tele
degrees
Page 3
NEC Display Solutions of America, Inc.
M311W Installation Guide
Ceiling Mounted and Desktop Rev 1.0
Cabinet Dimensions
The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
www.necdisplay.com M311W Page 3 of 6
Page 4
NEC Display Solutions of America, Inc.
M311W Installation Guide
Ceiling Mounted and Desktop Rev 1.0
Cabinet Dimensions (continued)
The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
www.necdisplay.com M311W Page 4 of 6
Page 5
NEC Display Solutions of America, Inc.
M311W Installation Guide
Ceiling Mounted and Desktop Rev 1.0
Optional Ceiling Mount Dimensions (Model #: M300CM)
The following drawings show the ceiling mount dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
www.necdisplay.com M311W Page 5 of 6
Page 6
NEC Display Solutions of America, Inc.
M311W Installation Guide
Ceiling Mounted and Desktop Rev 1.0
Input / Output Panel
PC Control Codes
Function Code Data
POWER ON 02H 00H 00H 00H 00H 02H POWER OFF 02H 01H 00H 00H 00H 03H INPUT SELECT COMPUTER1 02H 03H 00H 00H 02H 01H 01H 09H INPUT SELECT COMPUTER21 02H 03H 00H 00H 02H 01H 02H 0AH INPUT SELECT HDMI 02H 03H 00H 00H 02H 01H 1AH 22H INPUT SELECT VIDEO 02H 03H 00H 00H 02H 01H 06H 0EH INPUT SELECT S-VIDEO 02H 03H 00H 00H 02H 01H 0BH 13H INPUT SELECT VIEWER 02H 03H 00H 00H 02H 01H 1FH 27H INPUT SELECT NETWORK 02H 03H 00H 00H 02H 01H 20H 28H INPUT SELECT USB DISPLAY 02H 03H 00H 00H 02H 01H 22H 2AH PICTURE MUTE ON 02H 10H 00H 00H 00H 12H PICTURE MUTE OFF 02H 11H 00H 00H 00H 13H SOUND MUTE ON 02H 12H 00H 00H 00H 14H SOUND MUTE OFF 02H 13H 00H 00H 00H 15H PROJECTOR INFORMATION REQUEST 00H BFH 00H 00H 01H 02H C2H ERROR STATUS REQUEST 00H 88H 00H 00H 00H 88H INFORMATION REQUEST 03H 8AH 00H 00H 00H 8DH
Note: Contact your NEC rep for codes not listed.
Cable Connection
Communication Protocol:
Baud Rate: 38400 bps Data Length: 8 bits Parity: No Parity Stop Bit: One Bit X on/off: None Communications: Full duplex
12
67 8
34
PC Control Connector (D-Sub 9P)
NOTE 1 : Pins 1, 4, 6, and 9 are used inside the projector. NOTE 2: For long cable runs it is recomme nd ed to set communication speed within the projector to 9600 bps. NOTE 3: Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection.
To TxD of PC
To RxD of PC
To GND of PC
5
9
To RTS of PC To CTS of PC
www.necdisplay.com M311W Page 6 of 6