NEC M310, M110 Configuration Manual

NEC
M110/M310 Disk Array
Configuration Guide
Rev.1.2
21 May 2015
Information of disclosure and limitation of usage
NEC Corporation has all the rights about this material. You can not use this material for any purposes other than provided purpose. In addition, you can not duplicate, modify and disclose this material to any third party without permission of NEC Corporation. Meanwhile, we may change the contents of this guide without notice in the future.
NEC Corporation
Rev Date of revision Contents of revision
1.0 2014.10.1 First edition
1.1 2014.12.15 Chap2. M110 Component Selection (20) Correct Model Number (NF9120-SJ93/NF9120-SJ95)
Chap2. M310 Component Selection (18)
Correct cache capacity (NF5332-SC01SE/NF5332-SC02SE)
1.2 2015.05.21 New Feature
Support DC Power Supply Model Support SAS Disk Drive (2.5” 10krpm/1.8TB) *1 Support SAS SSD (2.5” 200GB, 3.5” 200GB) *1 Support NL-SAS Disk Drive (3.5” 7.2krpm/6TB) *1
1
NEC Confidential
*1 Storage Control Software Revision 0920 or above, and NEC StorageManager Ver9.2 or
above are required.
Table of Contents
1. Specifications ……….………………………………………………………….. 3
2. Component Selection
M110 Component Selection .………………………………………………... 5
M310 Component Selection .………………………………………………... 30
3. Rack Guide ……………………………………………………………………... 51
4. Disk Drive ….……………………………………………………………………. 52
5. Functions ……………………………………………….……………………….. 54
Appendix: Dynamic Pool Capacity List ..……………………………… Excel sheet
2
NEC Confidential
1. Specifications <M110>
3
NEC Confidential
M110
2.5" HDD: Max. 24 HDDs per controller or disk enclosure unit.
3.5" HDD: Max. 12 HDDs per controller or disk enclos ure unit.
Max. 120 HDDs supported. Up to four disk enc losure units with 2. 5" HDD and/or up to nine disk enclosur e units w ith 3.5" HDD can be connected to the controller unit.
SAS/NL-SAS/SSD are suppor ted on the sam e controller and disk enc losure unit. 2.5" and 3.5" m ixed HDD environments are not support ed on the same controller and disk enclos ure unit.
FC 8/16Gb x 2-8
10Gb x 2-8
1/10Gb x 2/4/8
SAS 12Gb x 4/8
8/16G FC x 2-4 + 10G iSCSI x 2-4
8/16G FC x 2-4 + 1/10G iSCSI x 2/4
Capacity
GB(single c ontroller]), 16GB(Dual c ontroller)
Backup tim e Unlimited
1 or 2
12Gbps SAS x 2(dual c ontroller), 12Gbps SAS x 1(si ngle controller)
SAS
300GB(15Krpm ), 600GB(15Krpm), 600GB (10Krpm), 1.2TB(10krpm ),
1.8TB(10krpm )
NL-SAS 2TB(7.2Krpm ), 4TB(7.2Krpm ), 6TB(7.2Krpm)
200GB, 400GB, 1.6TB
200GB, 400GB, 1.6TB
SAS (Max transfer s peed 12Gbps) x 2
120 units
(*3)
12 units
0, 1, 5, 6, TM, 10, 50, 60
1, 10, 5(4+P ), 50(4+P ), 6(4+PQ) /(8+PQ), 60(4+ PQ)(8+PQ)
Dimens ions 482 x 556.0 x 87.4 (2U)
Weight 31kg or less
AC:100 - 240V, DC: 48V
FC 505W
iSCSI(Opt ical) 510W
iSCSI(Copper ) 515W
Combo(O ptical) 510W
Combo(C opper) 510W
SAS 500W
FC 510W
iSCSI(Opt ical) 510W
iSCSI(Copper ) 520W
Combo(O ptical) 510W
Combo(C opper) 515W
SAS 505W
FC 455W
iSCSI(Opt ical) 455W
iSCSI(Copper ) 465W
Combo(O ptical) 455W
Combo(C opper) 460W
SAS 450W
350W
350W
3.5" 295W
Operating: 5 to 40°C, 10 - 80% Non-Operating: - 10 to +60℃, 5 - 80%
Windows , Linux,
VMware, Hyper-V, KVM
Intel Ivy Bridge 800 W x2 per Base unit. Hot Swap and R edundancy Support 800 W x2 per Base unit. Hot Swap and R edundancy Support
*2 Available to Hot swap,driv e failure detection and reb uild *3 Refer t o P.26 Com ponent Selection(21) [CAUTION:The Number of Disk Enclosur es] *4 See Suppor t matrix f or detailed information
*1 Support disk encryption f or SAS 2.5" 600GB(15krpm) , SAS 2.5" 600GB(10krpm ), NL-SAS 4TB(7.2krpm),
SSD 2.5" 200GB, and SS D 3.5" 200GB.[Not suppor ted in China]
2.5"
3.5"
2.5"
SAS(15k)
NL SAS(7.2k)
2.5"
SAS(15k)
SAS(10k)
Temperatur e / Humidity c onditions
3.5"
Hypervisor
Supported OS
(*4)
Open OS
Max Power cons umption (W)
DE
DAC
NL SAS(7.2k)
SAS(10K)
Number of c ontrollers
Power s upply
SSD
with 3.5" HDDs
SSD
SAS, NL-SAS
RAID levels
W x D x H mm
2.5"
3.5"
Optical
Copper
8/16G FC/10G iSCSI(O ptical)
Item
Host interfac e / Number of hos t ports
Cache
Chassis configuration
8/16G FC/10G iSCSI(Copper )
Intermix
Type of Proc essor
Power supply (include Fan)
Disk Array C ontroller
Disk Enc losure
Disk D rive
(*1,* 2)
iSCSI (10Gb)
Max. number of SSD
Disk I/F
Disk Enc losure
Max. number of disk dri ves
1. Specifications <M310>
4
NEC Confidential
M310
2.5" HDD: Max. 24 HDDs per controller or disk enclos ure unit.
3.5" HDD: Max. 12 HDDs per controller or disk enclos ure unit.
2.5" HDD: Max. 480 HDDs supported.
3.5" HDD: Max. 240 HDDs supported.
SAS/NL-SAS/SSD are supported on the same c ontroller and disk enclosur e unit. 2.5" and 3.5" mixed HDD environments are not supported on the sam e controller and dis k enclos ure unit.
8/16Gb x 2-8
10Gb x 2-8
1/10Gb x 8
8/16G FC x 2-4 + 10G iSCSI x 2-4
8/16G FC x 2-4 + 10G iSCSI x 4
24/48GB
Unlimited
2
12Gbps SAS x 2
300GB(15Krpm), 600GB(15Krpm ), 600GB(10Krpm), 1.2TB(10krp m),
1.8TB(10krpm )
2TB(7.2Krpm ), 4TB(7.2Krpm), 6TB(7.2Krpm )
200GB, 400GB, 1.6TB
200GB, 400GB, 1.6TB
SAS (Max transfer speed 12Gbps) x 2
480 units(2.5"), 240 units(3.5")
(*3)
480 units(2.5"), 240 units(3.5")
(*3)
0, 1, 5 ,6, TM, 10, 50, 60
1, 10, 5(4+P), 50(4+P ), 6(4+PQ)/( 8+PQ), 60(4+ PQ)/( 8+PQ)
Dim ensions 482 x 556.0 x 87.4 (2U)
Weight 31kg or less
AC:100 - 240V, DC 48V
FC 550W
iSCSI(Opt ical) 555W
iSCSI(Copper ) 560W
Combo( Optical) 555W
Combo( Copper) 555W
FC 555W
iSCSI(Opt ical) 560W
iSCSI(Copper ) 565W
Combo( Optical) 555W
Combo( Copper) 560W
FC 500W
iSCSI(Opt ical) 500W
iSCSI(Copper ) 510W
Combo( Optical) 500W
Combo( Copper) 505W
350W
350W
3.5" 295W
Operating: 5 to 40, 10 - 80% Non-Operating: -10 to +60℃, 5 - 80%
Window s, Linux, Solaris, HP-UX, AIX
VMWare, Hyper-V, KVM
Intel Ivy Bridge
800 W x4 per Base unit.
Hot Swap and Redundanc y Support
800 W x4 per Base unit.
Hot Swap and Redundanc y Support
*2 Available to Hot swap,drive failure detect ion and rebuild *3 R efer to P.47 Com ponent Selection(17) [CAUTION:The Number of D isk Enclosures ]
*4 See Support matrix for detailed information
*1 Support dis k encryption for SAS 2.5" 600GB(15krpm), S AS 2.5" 600GB(10krpm), NL-SAS 4TB(7.2krpm),
SSD 2.5" 200GB, and SSD 3.5" 200GB.[Not supported in China]
SAS(10k)
2.5"
3.5"
3.5"
2.5"
SAS(15k)
Disk Array C ontroller
SAS, NL-SAS
SSD
Item
Chassis configuration
Host interface / Number of host ports
FC
iSCSI (10Gb)
Intermix
8/16G FC/10G iSCS I(Optical)
8/16G FC/10G iSCS I(Copper)
Backup Tim e
Number of co ntrollers
DAC-DE I/F
SSD
NL-SAS
2.5"
Optical
Copper
DE
2.5"
Disk E nclosur e
Max. number of disk drives
DAC
3.5"
Cache
Capacity
NL SAS(7.2k)
Max Power cons umption (W)
Disk D rive
(*1, *2)
SAS
NL SAS(7.2k)
SAS(15k)
Max. number of SSD
RAID Level
W x D x H mm
Power s upply (include Fan)
Type of Processor
with 3.5" HDD s
Power Supply
Disk E nclosur e
Temper ature / Humidity conditions
Supported O S
(*3)
Open O S
Hypervisor
SAS(10k)
M110 Component Selection
5
NEC Confidential
2. M110 Component Selection (1)
n Structure
M110 Disk Array is a compact and entry level disk storage system in NEC Storage M-Series. M110 has the following host interfaces: 8/16Gb FC, 1/10Gb iSCSI, 12Gb SAS, Combo(FC and iSCSI). M110 base units support 24x 2.5” drives and 12x 3.5” drives per 2U chassis. Disk enclosures can include a mix of SAS disk drives, Nearline SAS disk drives and SAS SSD. Disk drives can be added to the maximum 120 disk drives by connecting disk enclosures.
n Overview : M110 Disk Array (2.5”)
6
NEC Confidential
SAS HDD/SAS SSD
SAS HDD/SAS SSD
SAS HDD/SAS SSD
Controller
BBU
Switch
Switch
Base unit
Power
Fan
DE#01
Switch
Switch
DE#04
Switch
Switch
Disk Enclosure
Refer to “The Number of Disk Enclosures”
Controller
Cache 8GB
BBU
Cache 8GB
DE#00Build-in
Power
Fan
Power
Disk Enclosure
Power
Fan
Fan
Host Port Card
SFP
SFP
Host Port Card
Fan
PowerSupply
Fan
PowerSupply
DISK Port
DISK Port
2. M110 Component Selection (2)
n Overview : M110 Disk Array (3.5”)
7
NEC Confidential
Controller
BBU
Switch
Switch
Base Unit
Power
Fan
DE#01
Switch
Switch
DE#09
Switch
Switch
Disk Enclosure
NL-SAS HDD/SAS SSD
Refer to “The Number of Disk Enclosures”
ControllerCache 8GB
BBU
Cache 8GB
NL-SAS HDD/SAS SSD
NL-SAS HDD/SAS SSD
DE#00Built-in)
Power
Fan
Power
Disk Enclosure
Power
Fan
Fan
Host Port Card
Fan
PowerSupply
Fan
PowerSupply
SFP
SFP
Host Port Card
DISK Port DISK Port
2. M110 Component Selection (3)
n Steps for Component Selection When Purchasing a New System
n Steps for Expansion
(4) Select Disk Enclosure (Number, Type, Power)
2.5” 3.5”
Refer to (2-1) Disk Array Unit, a) Base Unit
(1) Select Model of Disk Array Unit (Power/Disk Size)
(3) Select Disk Drive
(Type, Capacity, Number, Function/Hot Spare Disk)
2.5” 3.5”
Select Encryption
Function
SAS SSD NL-SAS SSD
Select Encryption
Function
Refer to (4) Disk Enclosure
Refer to (2-1) Disk Array Unit, b) Host Port Card
Refer to (3-1) Disk Drive
(2) Host Port Card (Host I/F)
(1)Select Model of Disk Array Unit
Add Server
/ HBA / NIC/
SAS Controller
Expand Disk
Capacity
(3)Select Disk Drive (5)Select Dummy HDD
(4)Select Disk Enclosure (6)Select Front Bezel
(7)Select Rack
(7) Select Rack
(6) Select Front Bezel
Refer to (6) Front Bezel
Refer to 3. Rack Guide
(5) Select Dummy HDD
Refer to (5) Dummy HDD
8
NEC Confidential
FC/10Gb iSCSI Combo
8Gb FC 12Gb SAS16Gb FC
1/10Gb iSCSI(Copper)
10Gb iSCSI(Optical)
2.5” 3.5”
Power SupplyAC,DC
Single Controller
Dual Controller
2.5” 3.5”
(2)Host Port Card
If FC, choose 8/16Gb FC 2/4/8 ports.
If 1Gb iSCSI, choose 1Gb iSCSI Copper 2/4/8 ports.
If 10Gb iSCSI, choose 10Gb iSCSI Copper/Optical 2/4/8 ports. If 12Gb SAS, choose 12Gb SAS 4/8 ports. If Combo, choose 8/16Gb FC 2/4 ports and 1/10Gb iSCSI
Copper/Optical 2/4 ports.
Ø Refer to M110 Component Selection (2-1): Product List,
b) Host Port Card
Ø Refer to M110 Component Selection (2-3) Choose Host
I/F
Choose Dual Controller Configuration (Controller card x 2) Ø Refer to M110 Component Selection (2-4): Dual
Controller vs. Single Controller
Choose M110 Disk Array Unit (2.5” model) Ø Refer to M110 Component Selection (2-1): Product List,
a) Base Unit
2. M110 Component Selection (4)
(1) System Requirement and Recommended Product
Choose Single Controller Configuration (Controller Card x
1) Ø Refer to M110 Component Selection (2-4): Dual
Controller vs. Single Controller
YES
NO
(3) High reliability and
availability are required.
YES
(2) Space-saving is
required.
(1) Host I/F is determined.
(4) Low cost is required.
YES
YES
An M110 Disk Array Unit does not include disk drives. A controller unit is not included with a base unit. Both the array controller unit and a controller card are required. The following steps and lists are references for choosing an appropriate product combination.
9
NEC Confidential
2. M110 Component Selection (5)
Model Number Product Name Remarks Accessories
*1
NF5322-SR01E
M110 Disk Array Unit
(2.5“)
• Power supply unit AC 100-240V
• 24 x 2.5” disk drives
• NEC Storage Rack Mount Kit
• List of accessories
• Ear Bezels *2(left and right)
• HW Document CD (User Guide, Setup Guide, Installation Guide)
• NEC Storage PathManager CD (Windows, Linux)
NF5322-SR00E
M110 Disk Array Unit
(3.5”)
• Power supply unit AC 100-240V
• 12 x 3.5” disk drives
NF5322­SR01DE
M110 Disk Array Unit
(2.5“) (DC 48V)
• Power supply unit DC 48V
• 24 x 2.5” disk drives
• NEC Storage Rack Mount Kit
• List of accessories
• Ear Bezels *2(left and right)
• HW Document CD (User Guide, Setup Guide, Installation Guide)
• NEC Storage PathManager CD
(Windows, Linux)
• DC Cables
NF5322­SR00DE
M110 Disk Array Unit
(3.5”) (DC 48V)
• Power supply unit DC 48V
• 12 x 3.5” disk drives
(2) Disk Array Unit (2-1) Base Unit
10
NEC Confidential
a) Dual controller
Model Number Product Name Remarks Accessories
*1
NF5322­SR01SE
M110 Disk Array Unit
(2.5“) Single
Controller model
• Power supply unit AC 100-240V
• 24 x 2.5” disk drives
• NEC Storage Rack Mount Kit
• List of accessories
• Ear Bezels *2(left and right)
• HW Document CD (User Guide, Setup Guide, Installation Guide)
• NEC Storage PathManager CD (Windows, Linux)
NF5322­SR00SE
M110 Disk Array Unit
(3.5”) Single
Controller model
• Power supply unit AC 100-240V
• 12 x 3.5” disk drives
b) Single Controller
*3
Model Number Product Name Remarks Accessories
*1
NF5322-SP00E
M110 option
Controller
For M110 single Controller model
• List of accessories
c) Option Controller for Single Controller model
*1No front bezel is attached in M-Series Disk Array Units. If necessary, purchase it separately. *2Ear bezels indicate the black cover panels at both ends of base unit.
*3No support on snapshot, data replication and cluster functions in Single Controller Configuration.
Refer to (2-4) Dual Controller vs. Single Controller for more details.
Ear bezel Ear bezel
NEC Confidential
11
2. M110 Component Selection (6)
Model
Number
Product Name Remarks Accessories
NF5322-
SF05E
Host Port Card
(FC 2Ports)
Host Port card x 1(SFP module-less)
- Blank slot x2 for FC SFP
List of accessories
NF5322-
SF06E
Host Port Card
(FC 4Ports)
Host Port card x 1(SFP module-less)
- Blank slot x4 for FC SFP
List of accessories
NF5322-
SF21E
Host Port Card
(10Gb iSCSI optical 2Ports)
Host Port card x 1(SFP module-less)
- Blank slot x2 for 10Gb iSCSI optical SFP
List of
accessories
NF5322-
SF22E
Host Port Card
(10Gb iSCSI optical 4Ports)
Host Port card x 1(SFP module-less)
- Blank slot x4 for 10Gb iSCSI optical SFP
List of accessories
NF5322-
SF23E
Host Port Card
(10Gb iSCSI Copper 2Ports)
Host Port card x 1
- 1/10Gb iSCSI Copper 2port
List of accessories
NF5322-
SF24E
Host Port Card
(10Gb iSCSI Copper 4Ports)
Host Port card x 1
- 1/10Gb iSCSI Copper 4port
List of
accessories
NF5322-
SF44E
Host Port Card
(12Gb SAS 4Ports)
Host Port card x 1
- 12Gb SAS 4port
List of accessories
NF5322-
SF83E
Host Port Card
(FC/10Gb iSCSI Optical Combo)
Host Port card x 1
- Blank slot x2 for FC SFP
- Blank slot x2 for 10Gb iSCSI optical SFP
List of accessories
NF5322-
SF84E
Host Port Card
(FC/10Gb iSCSI Copper Combo)
Host Port card x 1
- Blank slot x2 for FC SFP
- Blank slot x2 for 1/10Gb iSCSI copper
List of
accessories
2-2) Host Port Card
NEC Confidential
12
2. M110 Component Selection (7)
(2-3) SFP Module for FC, iSCSI(Optical), and Combo
In case of SFP module-less host port card, it is required to purchase appropriate SFP module. Refer to the following table and available SFP module combination on next page for appropriate SFP type and quantity.
Model Number Product Name Remark
NF5322-SFP08E SFP Module(8Gb FC) SFP module 8Gb FC x2 NF5322-SFP16E SFP Module(16Gb FC) SFP module 16Gb FC x2
NF5322-SFP10E SFP Module(10Gb iSCSI Optical) SFP module 10Gb iSCSI Optical x2
SFP(Small Form factor Pluggable) module SFP module is kind of the transceiver to communicate in a Fibre channel or Gigabit Ethernet. The connection of the apparatus is enabled by putting it on Host Port Card. Therefore, the arrangement of the SFP module becomes required.
Port
combination
per unit
8Gb FC SFP
[NF5322-SFP08E]
16G FC SFP
[NF5322-SFP16E]
8G FC 2Port 1 0
8G FC 4Port 2 0
8G FC 6Port 3 0
8G FC 8Port 4 0
16G FC 2Port 0 1
16G FC 4Port 0 2
16G FC 6Port 0 3
16G FC 8Port 0 4
8G FC 2Port 16G FC 2Port
1 1
8G FC 2Port 16G FC 4Port
1 2
8G FC 2Port 16G FC 6Port
1 3
8G FC 4Port 16G FC 2Port
2 1
8G FC 4Port 16G FC 4Port
2 2
8G FC 6Port 16G FC 2Port
3 1
Available SFP Module combination for Host Port Card (FC 4Port) [NF5322-SF06E]
The following table shows available SFP combination in case of M110 disk array(dual controller)
with two Host Port Card(FC 4Port).
Max 8 SFPs (corresponded to 4-Model Number) per unit are available.
2. M110 Component Selection (8)
NEC Confidential
13
M110 M110
* Caution for installation of FC SFP module
Mixed installation with 8Gb FC SFP and 16Gb FC SFP is available. However, you need to install each
SFP at the same position when you set up dual controller configuration.
Controller 1
Host Port Card
Port0 Port1 Port2 Port3
・・・SFP module (8Gb FC)
・・・SFP module 16Gb FC)
Controller 1
Host Port Card
Port0 Port1 Port2 Port3
Controller 0
Host Port Card
Port0 Port1 Port2 Port3
Controller 0
Host Port Card
Port0 Port1 Port2 Port3
2. M110 Component Selection (9)
NEC Confidential
14
NG
Good
Port
combination
per unit
8Gb FC SFP
[NF5322-SFP08E]
16G FC SFP
[NF5322-SFP16E]
8G FC 2Port 1 0
8G FC 4Port 2 0
16G FC 2Port 0 1
16G FC 4Port 0 2
8G FC 2Port 16G FC 2Port
1 1
The following table shows available SFP combination in case of M110 disk array(single controller) with
one Host Port Card(FC 4Port).
Max 4 SFPs (corresponded to 2-model Number) per unit are available.
Available SFP Module combination for Host Port Card(10Gb iSCSI Optical 4Port) [NF5322-SF22E]
The following table shows available SFP combination in case of M110 disk array(dual controller)
with two Host Port Card(10Gb iSCSI Optical 4Port).
Port combination
per unit
10Gb iSCSI Optical SFP
[NF5322-SFP10E]
10G iSCSI Optical 2Port
1
10G iSCSI Optical 4Port
2
10G iSCSI Optical 6Port
3
10G iSCSI Optical 8Port
4
The following table shows available SFP combination in case of M110 disk array(single controller)
with two Host Port Card(10Gb iSCSI Optical 4Port).
Port combination
per unit
10Gb iSCSI Optical SFP
[NF5322-SFP10E]
10G iSCSI Optical 2Port
1
10G iSCSI Optical 4Port
2
2. M110 Component Selection (10)
Max 8 SFPs (corresponded to 4-Model Number) per unit are available.
Max 4 SFPs (corresponded to 2-Model Number) per unit are available.
NEC Confidential
15
Available SFP Module combination for Host Port Card(FC/10Gb iSCSI Optical) [NF5322-SF83E]
The following table shows available SFP combination in case of M110 disk array(dual controller) with
two Host Port Card(FC / 10Gb iSCSI Optical).
Port combination
per unit
8Gb FC SFP
[NF5322-SFP08E]
16G FC SFP
[NF5322-SFP16E]
10Gb iSCSI Optical SFP
[NF5322-SFP10E]
8G FC 2Port 10G iSCSI Optical 2Port
1 0 1
16G FC 2Port 10G iSCSI Optical 2Port
0 1 1
Port combination
per unit
8Gb FC SFP
[NF5322-SFP08E]
16G FC SFP
[NF5322-SFP16E]
10Gb iSCSI Optical SFP
[NF5322-SFP10E]
8G FC 2Port 10G iSCSI Optical 2/4Port
1 0 1 or 2
8G FC 4Port 10G iSCSI Optical 2/4Port
2 0 1 or 2
16G FC 2Port 10G iSCSI Optical 2/4Port
0 1 1 or 2
16G FC 4Port 10G iSCSI Optical 2/4Port
0 2 1 or 2
8G FC 2Port 16G FC 2Port 10G iSCSI Optical 2/4Port
1 1 1 or 2
The following table shows available SFP combination in case of M110 disk array(single controller) with one Host Port Card(FC / 10Gb iSCSI Optical).
2. M110 Component Selection (11)
Max 4 iSCSI SFPs (corresponded to 2-Model Number) per unit are available.
Max 4 FC SFPs (corresponded to 2­Model Number) per unit are available.
Max 2 iSCSI SFPs (corresponded to 1­Model Number) per unit are available.
Max 2 FC SFPs (corresponded to 1­Model Number) per unit are available.
NEC Confidential
16
Available SFP Module combination for Host Port Card(FC/10Gb iSCSI Copper) [NF5322-SF84E]
Host Port Card(FC/10Gb iSCSI Copper) initially has 2port of 10Gb iSCSI Copper.
The following table shows available SFP combination in case of M110 disk array(dual controller) with
two Host Port Card(FC / 10Gb iSCSI Copper).
Port combination
per unit
8Gb FC SFP
[NF5322-
SFP08E]
16G FC SFP
[NF5322-
SFP16E]
8G FC 2Port 10Gb iSCSI Copper 2Port
1 0
16G FC 2Port 10Gb iSCSI Copper 2Port
0 1
Port combination
per unit
8Gb FC SFP
[NF5322-
SFP08E]
16G FC SFP
[NF5322-
SFP16E]
8G FC 2Port 10Gb iSCSI Copper 4Port
1 0
8G FC 4Port 10Gb iSCSI Copper 4Port
2 0
16G FC 2Port 10Gb iSCSI Copper 4Port
0 1
16G FC 4Port 10Gb iSCSI Copper 4Port
0 2
8G FC 2Port 16G FC 2Port 10Gb iSCSI Copper 4Port
1 1
The following table shows available SFP combination in case of M110 disk array(single controller)
with one Host Port Card(FC / 10Gb iSCSI Copper).
Unit with two FC/10Gb iSCSI Copper Host Port Card, has initially four 10 Gb iSCSI Copper ports.
2. M110 Component Selection (12)
Max 4 FC SFPs (corresponded to 2-Model Number) per unit are available.
Unit with one FC/10Gb iSCSI Copper Host Port Card, has initially two 10 Gb iSCSI Copper ports.
Max 2 FC SFPs (corresponded to 1­Module Number) per unit are available.
NEC Confidential
17
2. M110 Component Selection (13)
(2-4) Choose Host I/F
Notes: Single Controller Configuration
1) There is a case where the system crashes when a controller fails and although it is extremely rare, data integrity cannot be guaranteed. To maintain higher reliability, a dual controller configuration (standard model) is recommended.
2) Since write-cache is off, the write process does not use cache.
• 8/16Gb FC: High speed interface
• 10Gb iSCSI(Optical): High speed and easy connection interface
• 1/10Gb iSCSI(Copper): Low cost and easy connection interface
• 12Gb SAS: Low cost DAS(Direct Attached Storage) interface
• 16Gb FC and 10Gb iSCSI : Combo
(2-5) Dual Controller vs. Single Controller
18
NEC Confidential
u Characteristics
Pros High Functionality/High Availability Data Protection Online Firmware update Snapshot, In-box/Inter-box Replication
Cons Higher cost than single controller configuration
u Usage
Dual controller storage for requiring 24 hours x 7 days operation
(e.g.) System that provides services to users such as database
and groupware operation, etc.
Dual Controller Configuration
(Standard Model)
Single Controller Configuration
(Low Cost Model)
uCharacteristics
Pros
Lower cost than dual controller configuration
Cons
No support on cluster/FT server No snapshot/data replication No online Firmware upgrade
Usage
Single Controller storage for back up data as the primary back up
(e.g.) System which has a backup server connected with a
storage unit (single controller) as the primary backup and a tape drive as the secondary backup.
cont. cont.
cont.
2. M110 Component Selection (14)
(2-6) NEC StorageManager Suite
NEC StorageManager Express is embedded in storage M110. This software can manage an M110 with basic functionalities and no management server is necessary. W hen more functions are required such as data replication, purchase NEC StorageManager Suite that requires a management server. Refer to the table below for functions which are available with NEC StorageManager Suite.
*1FC and iSCSI host I/F are supported. SAS host I/F is not supported.
NEC StorageManager Suite specific functions
[] designates optional product packages which can be purchased with
NEC StorageManager Suite.
Supported Storage
M110
Monitor multiple storages
Linkage with ESMPRO
Linkage with SigmaSystemCenter
Event Link (Report by e-mail. Run executable)
Monitor performance [NEC Storage PerformanceMonitor]
Analyze performance [NEC Storage PerformanceNavigator]
Alert (Express Alert, cooperate with syslog)
In-box replication [NEC Storage DynamicDataReplication]
Inter-box replication [NEC Storage RemoteDataReplication]
*1
Prevent unauthorized access or modification of data [NEC Storage VolumeProtect]
19
NEC Confidential
○:Supported -:Not supported
2. M110 Component Selection (15)
Slots #00, #01, and #02 must be populated.
(3) Disk Drive (3-1) Disk Drive
When deciding how many disk drives are required, remember that logical disk capacity varies depending on disk drive type (I/F, capacity) and RAID type. The number of disk drives is dependent on
the amount of logical disk capacity that is required. The amount of required logical disk capacity varies depending on the amount of data usage and whether or not features (Snapshot, Replication) are required. Using required logical disk capacity and performance that is required, decide the number of disk drives, taking into account the disk drive type (I/F, capacity, rotation speed) and RAID type.
At least three disk drives have to be populated with any disk drive types (SAS/NL-SAS/SAS SSD)
Refer to “(5) Supported RAID” for supported RAID types.
(3-2) Disk Capacity (Considerations for System Volume)
A system volume, in which performance logs, etc. are automatically saved, is created in the first binding Pool. System volume capacity is 8.0 GB. (or 8.6GB if 1KB = 1000Byte)
(Considerations for Snapshot)
When using the snapshot feature, it is necessary to create a snapshot reservation area for replication of a master volume (snapshot).
(Considerations for Replication)
When implementing the replication feature, use the storage system information retention function* and create a replication reserved volume with the NEC StorageManager application. The capacity of a replication reserved volume is 8.0GB. (or 8.6GB if 1KB = 1000Byte)
When turning power off via a planned shutdown all storage system information (differential map, etc) will be backed up onto the replication reserved volume only if it was configured. If the replication reserved volume is not configured then storage system information will be lost on shutdown. When restarting after a planned shutdown, I/O load will be generated as data on the MV is fully copied to the RV. This startup load may be large enough to temporarily affect performance. It is recommended to operate 24 hours nonstop, especially if running without a replication reserved volume.
* Storage system information retention function is used to backup storage system information such as
the differential map between business volume (MV) and replication volume (RV) onto disk drives.
20
NEC Confidential
#00 #01 #02 #03 #04 #05 #06 #07 #08 #09 #0A #0B
#17
・・・
#00
#01
#02
#03
NEC Confidential 21
Considerations for Lifetime of Disk Drive
Lifetime of SAS HDD, Nearline SAS HDD and SAS SSD are 5 years.
2. M110 Component Selection (16)
(3-3) Disk Drive Type
Select a disk drive type from the following table and decide how many drives are needed.
2. M110 Component Selection (17)
22
NEC Confidential
Model Number Product Name
NF5322-SMA75E SAS Disk Drive(2.5" 15krpm/300GB ) NF5322-SMA78E SAS Disk Drive(2.5" 15krpm/600GB ) NF5322-SMA78LE
*1
SAS Disk Drive(2.5" 15krpm/600GB Self-encrypting) NF5322-SM768E SAS Disk Drive(2.5" 10krpm/600GB ) NF5322-SM768LE
*1
SAS Disk Drive(2.5" 10krpm/600GB Self-encrypting) NF5322-SM76AE SAS Disk Drive(2.5" 10krpm/1.2TB ) NF5322-SMB6CE
*3
SAS Disk Drive(2.5" 10krpm/1.8TB) NF5322-SSAG5E
*2
SAS SSD (2.5" 200GB) NF5322-SSAG5LE
*1 *2 *3
SAS SSD(2.5" 200GB Self-encrypting) NF5322-SSA96E
*2
SAS SSD (2.5” 400GB) NF5322-SSA9AE
*2
SAS SSD (2.5” 1.6TB) NF5322-SMA75GE SAS Disk Drive(2.5" 15krpm/300GB ) x 10 pcs NF5322-SMA78GE SAS Disk Drive(2.5" 15krpm/600GB ) x 10 pcs NF5322-SMA78LGE
*1
SAS Disk Drive(2.5" 15krpm/600GB Self-encrypting) x 10pcs NF5322-SM768GE SAS Disk Drive(2.5" 10krpm/600GB ) x 10 pcs NF5322-SM768LGE
*1
SAS Disk Drive(2.5" 10krpm/600GB Self-encrypting) x 10 pcs NF5322-SM76AGE SAS Disk Drive(2.5" 10krpm/1.2TB) x 10 pcs NF5322-SMB6CGE
*3
SAS Disk Drive(2.5" 10krpm/1.8TB) x 10 pcs NF5322-SSAG5GE
*2
SAS SSD (2.5" 200GB) x 10 pcs NF5322-SSAG5LGE
*1 *2 *3
SAS SSD(2.5" 200GB Self-encrypting) x 10 pcs NF5322-SSA96GE
*2
SAS SSD (2.5” 400GB) x 10 pcs NF5322-SSA9AGE
*2
SAS SSD (2.5” 1.6TB) x 10 pcs NF5322-SM708E NL-SAS Disk Drive(3.5" 7.2krpm/2TB) NF5322-SM70AE NL-SAS Disk Drive(3.5" 7.2krpm/4TB) NF5322-SM70ALE
*1
NL-SAS Disk Drive(3.5" 7.2krpm/4TB Self-encrypting) NF5322-SMB0CE
*3
NL-SAS Disk Drive(3.5" 7.2krpm/6TB) NF5322-SSAR5E
*2
SAS SSD (3.5" 200GB ) NF5322-SSAR5LE
*1 *2 *3
SAS SSD(3.5" 200GB Self-encrypting) NF5322-SSAF6E
*2
SAS SSD (3.5" 400GB ) NF5322-SSAFAE
*2
SAS SSD (3.5" 1.6TB) NF5322-SM708GE NL-SAS Disk Drive(3.5" 7.2krpm/2TB) x 10 pcs NF5322-SM70AGE NL-SAS Disk Drive(3.5" 7.2krpm/4TB) x 10 pcs NF5322-SM70ALGE
*1
NL-SAS Disk Drive(3.5" 7.2krpm/4TB Self- encrypting) x 10 pcs NF5322-SMB0CGE
*3
NL-SAS Disk Drive(3.5" 7.2krpm/6TB) x 10 pcs NF5322-SSAR5GE
*2
SAS SSD (3.5" 200GB) x 10 pcs NF5322-SSAR5LGE
*1 *2 *3
SAS SSD(3.5" 200GB Self-encrypting) x 10 pcs NF5322-SSAF6GE
*2
SAS SSD (3.5" 400GB) x 10 pcs NF5322-SSAFAGE
*2
SAS SSD (3.5" 1.6TB) x 10 pcs
*1 Encrypted HDDs are not supported in China
*2 In general, lead time of SSD is longer than lead time of HDD. When you order the SSD,
please consider two to three months lead time to get the SSD.
*3 Storage Control Software Revision 0920 or above, and NEC StorageManager Ver9.2 or
above are required.
2. M110 Component Selection (18)
(3-5) Supported RAID
NEC Storage M-Series supports the following RAID types. (Note: Only RAID-1, 10, 5/50(4+P), 6/60(4+PQ), 6/60(8+PQ) are supported with SSD)
(3-6) Dynamic Pool
NEC Storage M-Series supports only dynamic pools. LUN capacity can be modified dynamically. Capacity is constant regardless of the number of disk drives. It is slightly less than the table above. Striping is automatic when an applicable number of disk drives are used with RAID types that support it.
<Example> RAID-1 with 4 disk drives is automatically configured as RAID-10.
Refer to “5. Functions <Pool>” for more details about dynamic pool.
* RAID-0: Data is not protected.
RAID Type Configuration Number of physical disk drives Redundancy RAID Capacity
RAID-0 * None Physical disk capacity x 1
RAID-1/10 (1+1) x n 2 or more disk drives 1 Physical disk capacity x 1/2
RAID-5/50 (2+P) x n 3 or more disk drives 1 Physical disk capacity x 2/3
(4+P) x n 5 or more disk drives 1 Physical disk capacity x 4/5
(8+P) x n 9 or more disk drives 1 Physical disk capacity x 8/9
RAID-6/60 (4+PQ) x n 6 or more disk drives 2 Physical disk capacity x 2/3
(8+PQ) x n 10 or more disk drives 2 Physical disk capacity x 4/5
RAID-TM (1+1+1) x n 3 or more disk drives 2 Physical disk capacity x 1/3
(3-4) Disk Drive Usage
Both the base unit and SAS disk enclosures can include a mix of SAS disk drives/NL-SAS disk drives/SAS SSD and disk drives with different capacities and rotation speeds.
A pool must contain disk drives with the same interface. The capacity or rotation speed does not matter. However, it is strongly recommended to use devices of the same capacity and same rotation speed in a pool. When using different capacities of disk drive in a pool, the pool will be created based on the disk drive with the smallest capacity. In this case, the rest of larger disk drives are not available.
Since SAS and Nearline SAS are regarded as different interfaces, it is impossible to mix SAS and Nearline SAS in same pool. Also mix of HDD and SSD, mix of self-encrypting HDD and non-encrypting HDD is not available in same pool. For SSD, It is recommended to mix same SSD type and same capacity.
<Example> A pool configured by SAS disk drives (15krpm/300GB) and SAS disk drives (15krpm/600GB)
ØThe SAS disk drive (15krpm/600GB) is treated as a SAS disk drive (15krpm/300GB).
When using different speeds of disk drives in a pool, the pool will be created based on the slowest disk speed. In this case, performance will not be as good as expected because drives with faster speed are treated the same as drives with the slowest speed.
<Example> A pool configured by 2.5” SAS disk drives (15krpm/600GB) and 2.5” SAS disk drive(10krpm/600GB)
ØThe SAS disk drive (15krpm/600GB) is treated as a SAS disk drive (10krpm/600GB).
23
NEC Confidential
Loading...
+ 54 hidden pages