NEC Express5800-R120e-2M Data Sheet

Idle Category (1S and 2S only)
Category D: Managed Dual Installed Processor (2P) Servers
®
ENERGY STAR
Power and Performance Data Sheet
Model Name: Express5800/R120e-2M
System Characteristics
Form Factor Available Processor Sockets Available DIMM Slots / Max Memory Capacity ECC and/or Fully Buffered DIMMs Available Expansion Slots Minimum and Maximum # of Hard Drives Redundant Power Supply Capable? Power Supply Make and Model Delta Electronics, Inc. DPS-800QB A Power Supply Output Rating* (watts) Minimum and Maximum # of Power Supplies Input Power Range (AC or DC) Power Supply Efficiency at Specified Loadings* Power Supply Power Factor at Specified Loadings*
Operating Systems Supported Installed Operating System for Testing
* Note: Power supply information is for a single power supply only
System Configurations
Configuration ID N8100-2044Y N8100-2044Y N8100-2045Y Processor Information
Memory Information
Internal Storage
I/O Devices None SAS Raid Card x1
Power Supply Number and Redundancy Configuration Management Controller or Service Processor Installed? Yes Yes Yes
Other Hardware Features / Accessories None None None
Power Data
2 Socket Server 2 24slots / 1536GB max. DDR3-1600 ECC DIMMs 6 slots Min: 1hdd unit ; Max: 16 hdd units Yes
800W 1 to 2 115Vac and 230Vac
91.67@20%, 94.09@50%, 91.95@100%
0.96@20%, 0.99@50%, 0.99@100% Microsoft Windows Server 2008 R2 Standard
Microsoft Windows Server 2008 R2 Enterprise etc. Microsoft Windows Server 2008 R2 Standard
Minimum Typical Maximum
Intel Xeon E5-2640 v2
2GHz
DDR3-1600
4GB x4
SATA 6Gbps 7200rpm
250GB x1
DPS-800QB A
800W x1
Intel Xeon E5-2640 v2
2GHz
DDR3-1600
64GB x8
SAS 6Gbps 15000rpm
300GB x3
DPS-800QB A
800W x2
Intel Xeon E5-2650 v2
SAS 6Gbps 15000rpm
Fibre Channel card x1
Minimum Typical Maximum
2.6GHz
DDR3-1600
64GB x24
300GB x16
SAS Raid Card x1
SAS HBA card x1
Ethernet card x3
Ethernet riser card x1
DPS-800QB A
800W x2
ENERGY STAR Idle Power Allowance (1S and 2S only) 174W 1234W 3454W Measured Idle Power (watts) 99.4 164.4 313.3 Power at Full Load* (watts) 169.4 237.1 443.6 Benchmark / Method Used for Full Load Test Test Voltage and Frequency for Idle and Full Load Test Range of Total Estimated Energy Usage ** (kWh/year) 1741 to 2968 2880 to 4154 5489 to 7772 Link to Detailed Power Calculator (if available)
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100%
full load operation. The calculation also includes typical data center overhead at a ratio
Power and Performance for Benchmark #1
Benchmark Used and Type of Workload Avg. Power Measured During Benchmark Run 169.4W 237.1W 443.6W Benchmark Performance Score 71.00Mpixel/s 70.18Mpixel/s 93.14Mpixel/s Power Performance Ratio (perf score/avg. power) 0.42 0.30 0.21 Link to Full Benchm ark Report (Where Available) N/A N/A N/A
Benchmark #1Benchmark #2
Power and Performance for Benchmark #2 (optional)
Benchmark Used and Type of Workload Avg. Power Measured During Benchmark Run Benchmark Performance Score Power Performance Ratio (perf score/avg. power) Link to Full Benchm ark Report (Where Available)
Use SiSoftware Sandra Engineer Standard 2010.SP1a
230V / 60Hz
Minimum Typical Maximum
SiSoftware Sandra Engineer Standard 2010.SP1a
Minimum Typical Maximum
YesN
o
Yes
N
oNoY
es
Yes
N
o
NoNoNoNoNo
No
Include specific information on ENERGY STAR Qualified SKUs or configurations
ENERGY STAR Power and Performance Data Sheet
Model Name: Express5800/R120e-2M
Page 2 of 3
Power Saving Features
Processor Dynamic Voltage and Frequency Scaling Processor or Core Reduced Power States Power Capping Variable Speed Fan Control Based on Power or Thermal Readings Low Power Memory States Low Power I/O States Liquid Cooling Capability
Other1: Other2: Other3: Other4:
Shipment
Power and Temperature Measurement and Reporting
Enabled on
Input Power Available & Accuracy? Input Air Temp Available & Accuracy? Processor Utilization Available? Other Data Measurements Available & Accuracy? Compatible Protocols for Data Collection Averaging method and time period
Thermal Information*
Total Power Dissipation (watts) 169.4W 237.1W 443.6W Delta Temperature at Exhaust at Peak Temp. (˚C) 3.2 5.6 6.7 Airflow at Maximum Fan Speed (CFM) at Peak Temp. 65.5 70.6 72.5 Airflow at Nominal Fan Speed (CFM) at Nominal Temp. 51.1 53.8 42.8
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008
Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5 Peak temperature is defined as 35 ˚C, Nominal Tempera
Notes
1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on XX/XX/XX. For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org
Yes, +/- 5% for 80W ~800W , +/-10W for ~100W Yes, +/- 2(c) Yes
IPMI Non Averaging, 1 sec. interval sampling.
Minimum Typical Maximum
ENERGY STAR Qualified Configurations
End-User Enabling
Required
Qualified Configuration ID: N8100-2044Y, N 8100-2045Y, N8100-2072F(w/ E5-2640v2, 2650v2)