Key Features .......................................................................................................................................... 3
Note for Ordering ................................................................................................................................ 21
Server Management ............................................................................................................................ 21
OS Support Matrix for PCI Cards ...................................................................................................... 22
Supporting PCI cards and Installable Slots ..................................................................................... 22
Copyright Notice and Liability Disclaimer ........................................................................................ 23
REVISION HISTORY ..................................................................................................... 24
NEC Corporation Revision 1.0, February 2012 2
Page 3
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Model
GT110d-S
3.5-inch drive model
2.5-inch drive model
Part Number
N8100-1859F
N8100-1860F
Processor
Type
Intel® Core™ i3-2120 processor
Clock speed
3.30 GHz
Number of Processor
1
Cache
3 MB
Cores and Threads
2C / 4T
Chipset
Intel® C204 Chipset
Memory
Type
DDR3-1333 ECC Unbuffered DIMM
Standard capacity
0 GB
Maximum capacity
32 GB (4 x 8 GB)
Internal Storage
Standard capacity
0 GB
Maximum capacity
SATA : 6 TB (2 x 3 TB)
SAS: 2.7 TB (3 x 900 GB)
SATA : 3 TB (3x 1 TB)
SSD : 300 GB (3 x 100 GB)
Disk Controller
SATA : 3Gb/s (Integrated)
SATA : 3Gb/s (Integrated)
SAS: 6Gb/s (Optional)
RAID
SATA :
1 2
RAID 0/1
SATA :
1 2
RAID 0/1 (Standard),
RAID 5/6 (Optional)
SAS : RAID 0/1/5/6 (Optional)
Hot Plug
-
Supported
Optical Disk Drive
Slim DVD-ROM
3.5-inch Media Bays
[free]
1 [1]
Disk Drive Bays [free]
3.5-inch: 2 [2]
2.5-inch: 3[3]
Expansion Slots [free]
Total: 2 slots available
2 [2] x PCIe 2.0 x4 (x8 connector)
Video Controller (VRAM)
Integrated in Server Management Controller (32MB)
Interfaces
1 x VGA (15-pin mini D-sub,1x rear)
1 x Serial (9-pin mini D-sub, RS232-C, Serial A, 1 x rear)
8x USB2.0 (2 x front, 4 x rear, 2 x internal)
2x 1000BASE-T LAN connector (1000BASE-T / 100BASE-TX /
10BASE-T, RJ-45, 2 x rear)
1 x Management LAN connector (100BASE-TX / 10BASE-T,
RJ-45, 1 x rear)
Server Management
EXPRESSSCOPE Engine 3
System FAN
Standard
Technical Specification
Key Features
Ultra compact form of 93mm in width, 13 liter in volume
Up to 32 GB of high speed DDR3-1333 memory
Full manageability by integrated EXPRESSSCOPE Engine 3
Whisper quiet at 35dB in maximum configuration with operation status
Function in maximum 40° C / 104° F ambient temperature
Specification
NEC Corporation Revision 1.0, February 2012 3
Page 4
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Operating: 10° to 40° C / 50° to 104° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE
Operating systems
Microsoft® Windows Server® 2003 R2, Standard Edition SP2 or later
Microsoft® Windows Server® 2003 R2, Standard x64 Edition SP2 or later
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 Standard (x64)
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Enterprise (x64)
Microsoft Windows Server 2008 R2 Standard
Microsoft Windows Server 2008 R2 Enterprise
Red Hat Enterprise Linux 5.6 or later 4
Red Hat Enterprise Linux 5.6 or later (EM64T)
4
Red Hat Enterprise Linux 6.1 or later 4
Red Hat Enterprise Linux 6.1 or later (EM64T)
4
VMware ESXi™ 5.0
1
Embedded SATA RAID controller is supported only on Windows operating systems.
2
Embedded SATA RAID Controller does not support RAID 10 configured with 2TB and 3TB HDDs.
3
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
4
For Linux support, contact our sales representative or go to the NEC website at:
Microsoft Windows Server 2003 R2, Standard x64 Edition
Microsoft Windows Server 2008 Standard (x64)
Microsoft Windows Server 2008 R2 Standard (x64)
32 GB
64 GB
Microsoft Windows Server 2003 R2, Enterprise Edition
Microsoft Windows Server 2008 Enterprise
32 GB
1 TB
Microsoft Windows Server 2003 R2, Enterprise x64 Edition
32 GB
2 TB
Microsoft Windows Server 2008 Enterprise (x64)
Microsoft Windows Server 2008 R2 Enterprise (x64)
32 GB
16 GB
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 6
16 GB
256 GB
Red Hat Enterprise Linux 5 (EM64T)
32 GB
2 TB
Red Hat Enterprise Linux 6 (EM64T)
32 GB
Server Configuration
1 Base Models
2 Memory
Available slots: 4
NOTE:
One memory kit must be installed.
To install by double of memory kit is recommended in order to increase memory transfer
speed by the dual-channel symmetric configuration.
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
The maximum available memory is less than the maximum physical memory supported by your system
because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary
depending on the type and the number of PCI cards you are using.
NEC Corporation Revision 1.0, February 2012 8
Page 9
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Non-RAID
On-board SATA
RAID
Optional RAID
Controller
128MB Cache
512MB Cache
256MB Cache
Refer to 3.2.1
Refer to 3.2.2
Refer to 3.2.3
Refer to 3.2.4
RAID 0/1
SATA
SATA
SATA
SATA
Available Disk
Non-RAID
RAID 5/6
Embedded SATA
RAID
Optional RAID
Controller
128MB Cache
256MB Cache
512MB Cache
256MB Cache
Refer to 3.2.5
Refer to 3.2.6
Refer to3.2.7
Refer to 3.2.8
Refer to 3.2.9
RAID 0/1
SATA, SSD
SAS, SATA, SSD
SAS, SATA, SSD
SAS, SATA, SSD
SAS, SATA, SSD
Available Disk
3 Internal Hard Disk Drives
3.1 RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration
3.1.1 3.5-inch Drive
NOTE:
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
All hard drives within a RAID array should be of the same capacity.
An optional RAID controller occupies one PCI slot.
3.1.2 2.5-inch Drive
NOTE:
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
All hard drives within a RAID array should be of the same capacity and rotation speed.
Mixing SAS and SATA hard drives in the same system is not supported.
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller..
An optional RAID controller occupies one PCI slot.
NEC Corporation Revision 1.0, February 2012 9
Page 10
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
2 x SATA ports, RAID 0/1 capable
(Standard)
Cable
Internal SATA Cable
1x SATA to 1x SATA , 2 sets
(Standard)
HDD Cage
3.5-inch HDD Cage
2 x 3.5-inch non hot plug (fixed) hard drive bays
(Standard)
HDD
2 slots available
160GB HDD
1 x 160 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-372
250GB HDD
1 x 250 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-373
500GB HDD
1 x 500 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-343
1TB HDD
1 x 1 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-260
2TB HDD
1 x 2 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-284
3TB HDD
1 x 3 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-339
3.2 Internal Drive Configuration
3.2.1 3.5-inch Drive with Embedded SATA Controller
NOTE:
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
3 TB HDDs are not supported with the embedded SATA non-RAID controller.
All hard drives within a RAID array should be of the same capacity.
NEC Corporation Revision 1.0, February 2012 10
Page 11
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (128MB, RAID 0/1)
Promise SuperTrak TX8760T-128
RAID 0/1/10, 128MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA
3Gb/s, LP / FH
N8103-128
RAID BBU
Recommended
RAID Battery Backup Unit
for Promise SuperTrak EX8760T
N8103-141
Cable
Required
Internal SATA Cable
1x mini-SAS to 2x SATA
K410-253(00)
HDD Cage
3.5-inch HDD Cage
2 x 3.5-inch non hot plug (fixed) hard drive bays
(Standard)
HDD
2 slots available
160GB HDD
1 x 160 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-372
250GB HDD
1 x 250 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-373
500GB HDD
1 x 500 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-343
1TB HDD
1 x 1 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-260
2TB HDD
1 x 2 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-284
3TB HDD
1 x 3 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-339
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (256MB, RAID 0/1)
LSI MegaRAID SAS 9264-8i
RAID 0/1, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s,
LP / FH
N8103-129
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9264
N8103-121
Cable
Required
Internal SATA Cable
1x mini-SAS to 2x SATA
K410-253(00)
HDD Cage
3.5-inch HDD Cage
2 x 3.5-inch non hot plug (fixed) hard drive bays
(Standard)
HDD
2 slots available
160GB HDD
1 x 160 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-372
250GB HDD
1 x 250 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-373
500GB HDD
1 x 500 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-343
1TB HDD
1 x 1 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-260
2TB HDD
1 x 2 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-284
3.2.2 3.5-inch Drive with RAID 0/1 Controller with 128 MB Cache
NOTE:
All hard drives within a RAID array should be of the same capacity.
3.2.3 3.5-inch Drive with RAID 0/1 Controller with 256 MB Cache
NOTE:
All hard drives within a RAID array should be of the same capacity.
NEC Corporation Revision 1.0, February 2012 11
Page 12
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
Raid Controller(512MB, RAID0/1/5/6)
Promise SuperTrak EX8760T-512
RAID 0/1/5/6, 512MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA
3Gb/s, LP / FH
N8103-134
RAID BBU
Recommended
RAID Battery Backup Unit
for Promise SuperTrak EX8760T
N8103-141
Cable
Required
Internal SATA Cable
1x mini-SAS to 2x SATA
K410-253(00)
HDD Cage
3.5-inch HDD Cage
4 x 3.5-inch non hot plug (fixed) hard drive bays
(Standard)
HDD
2 slots available
160GB HDD
1 x 160 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-372
250GB HDD
1 x 250 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-373
500GB HDD
1 x 500 GB, 3.5-inch, SATA2, 7,200 rpm
N8150-343
1TB HDD
1 x 1 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-260
2TB HDD
1 x 2 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-284
3TB HDD
1 x 3 TB, 3.5-inch, SATA2, 7,200 rpm
N8150-339
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x SATA ports, RAID 0/1/10 capable
(Standard)
Cable
Required
Internal SATA Cable
3x SATA to 1x mini-SAS
K410-241(00)
HDD Cage
2.5-inch HDD Cage
3 x 2.5-inch hot plug hard drive bays
(Standard)
HDD
4 slots
available
SATA
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-276
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-277
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8150-334
SSD
100GB SSD
1 x 100 GB, 2.5-inch, SATA2
N8150-707
3.2.4 3.5-inch Drive with RAID 0/1 Controller with 512 MB Cache
NOTE:
All hard drives within a RAID array should be of the same capacity.
3.2.5 2.5-inch Drive with Embedded SATA Controller
NOTE
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
All hard drives within a RAID array should be of the same capacity and rotation speed.
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller..
NEC Corporation Revision 1.0, February 2012 12
Page 13
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (128MB, RAID 0/1)
Promise SuperTrak TX8760T-128
RAID 0/1, 128MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s,
LP / FH
N8103-128
RAID BBU
Recommended
RAID Battery Backup Unit
for Promise SuperTrak EX8760T
N8103-141
Cable
Required
Internal SAS/SATA Cable
1x mini-SAS to 4x Fixed SAS
K410-180(00)
HDD Cage
2.5-inch HDD Cage
3 x 2.5-inch hot plug hard drive bays
(Standard)
HDD
3 slots
available
SAS
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-374
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-375
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-376
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-377
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-332
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-378
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-379
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-331
SATA
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-276
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-277
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8150-334
SSD
100GB SSD
1 x 100 GB, 2.5-inch, SATA2
N8150-707
3.2.6 2.5-inch Drive with RAID 0/1 Controller with 128 MB Cache
NEC Corporation Revision 1.0, February 2012 13
All hard drives within a RAID array should be of the same capacity and rotation speed.
Mixing SAS and SATA hard drives in the same system is not supported.
NOTE:
Page 14
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (256MB, RAID 0/1)
LSI MegaRAID SAS 9264-8i
RAID 0/1, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 3Gb/s,
LP / FH
N8103-129
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9264
N8103-121
Cable
Required
Internal SAS/SATA Cable
1x mini-SAS to 4x Fixed SAS
K410-180(00)
HDD Cage
2.5-inch HDD Cage
3 x 2.5-inch hot plug hard drive bays
(Standard)
HDD
3 slots
available
SAS
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-374
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-375
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-376
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-377
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-332
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-378
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-379
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-331
SATA
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-276
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-277
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8150-334
SSD
100GB SSD
1 x 100 GB, 2.5-inch, SATA2
N8150-707
3.2.7 2.5-inch Drive with RAID 0/1 Controller with 256 MB Cache
NEC Corporation Revision 1.0, February 2012 14
All hard drives within a RAID array should be of the same capacity and rotation speed.
Mixing SAS and SATA hard drives in the same system is not supported.
NOTE:
Page 15
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (256MB, RAID 0/1/5/6)
LSI MegaRAID SAS 9264-8i
RAID 0/1/5/6/10/50, 256MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s,
SATA 3Gb/s, LP / FH
N8103-130
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9264
N8103-121
Cable
Required
Internal SAS/SATA Cable
1x mini-SAS to 4x Fixed SAS
K410-180(00)
HDD Cage
2.5-inch HDD Cage
3 x 2.5-inch hot plug hard drive bays
(Standard)
HDD
3 slots
available
SAS
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-374
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-375
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-376
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-377
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-332
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-378
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-379
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-331
SATA
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-276
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-277
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8150-334
SSD
100GB SSD
1 x 100 GB, 2.5-inch, SATA2
N8150-707
3.2.8 2.5-inch Drive with RAID 5/6 Controller with 256 MB Cache
NEC Corporation Revision 1.0, February 2012 15
NOTE:
All hard drives within a RAID array should be of the same capacity and rotation speed.
Mixing SAS and SATA hard drives in the same system is not supported.
Page 16
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
Raid Controller(512MB, RAID0/1/5/6)
Promise SuperTrak EX8760T-512
RAID 0/1/5/6/10/50, 512MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s,
SATA 3Gb/s, LP / FH
N8103-134
RAID BBU
Recommended
RAID Battery Backup Unit
for Promise SuperTrak EX8760T
N8103-141
Cable
Required
Internal SAS/SATA Cable
1x mini-SAS to 4x Fixed SAS
K410-180(00)
HDD Cage
2.5-inch HDD Cage
3 x 2.5-inch hot plug hard drive bays
(Standard)
HDD
3 slots
available
SAS
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-374
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-375
450GB HDD
1 x 450 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-376
600GB HDD
1 x 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-377
900GB HDD
1 x 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
N8150-332
73.2GB HDD
1 x 73.2 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-378
146.5GB HDD
1 x 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-379
300GB HDD
1 x 300 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
N8150-331
SATA
160GB HDD
1 x 160 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-276
500GB HDD
1 x 500 GB, 2.5-inch, SATA2, 7,200 rpm
N8150-277
1TB HDD
1 x 1 TB, 2.5-inch, SATA2, 7,200 rpm
N8150-334
SSD
100GB SSD
1 x 100 GB, 2.5-inch, SATA2
N8150-707
3.2.9 2.5-inch Drive with RAID 5/6 Controller with 512 MB Cache
NEC Corporation Revision 1.0, February 2012 16
NOTE:
All hard drives within a RAID array should be of the same capacity and rotation speed.
Mixing SAS and SATA hard drives in the same system is not supported.
Page 17
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Product Name / Description
Part Number
Slim DVD-ROM drive
(Standard)
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
N8151-104F
Category
Product Name / Description
Part Number
Controller
Internal USB Controller
1 x USB port or 1 x pin-header for front panel USB
(Standard)
Cable
Required
Internal USB Cable
1x Internal USB to 1x USB device
NOTE:
The cable is required to install USB tape drive only.
K410-255(00)
Internal USB Cable
1x pin-header for front panel USB to 1x USB device and 1x front
panel USB port
NOTE:
The cable is required to install internal flash memory and USB
tape drive.
A USB tape drive occupies one front USB port.
K410-245(00)
Drive
1 bay available
Internal DAT (USB)
DDS3 / DDS4 / DAT72, Native capacity 36 GB
NOTE: DDS1 / DDS2 format are not supported
N8151-69
DAT
DAT72
USB
Refer to 5.2.1
Refer to 5.2.2
USB
RDX
4 Internal Optical Drive
Available Bays: 1
NOTE:
To install internal DVD Super Multi drive, the standard DVD-ROM drive needs to be removed.
5 Internal Tape / RDX drives
5.1 Tape / RDX Drive Selection
Refer the section according to the type of tape drives.
NOTE:
No tape drive can be installed if you install optional 2.5-inch HDD Cage.
5.2 Tape / RDX Configuration
5.2.1 DAT / USB
NEC Corporation Revision 1.0, February 2012 17
Page 18
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Controller
Internal USB Controller
1 x USB port or 1 x pin-header for front panel USB
(Standard)
Cable
Required
Internal USB Cable
1x Internal USB to 1x USB device
NOTE:
The cable is required to install USB tape drive only.
K410-255(00)
Internal USB Cable
1x pin-header for front panel USB to 1x USB device and 1x front
panel USB port
NOTE:
The cable is required to install internal flash memory and USB
tape drive.
A USB tape drive occupies one front USB port.
K410-245(00)
Drive
1 bay available
Internal RDX (USB)
N8151-86
Product Name / Description
Part Number
Internal Flash Memory
Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without
DVD media
NOTE:
Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the
flash memory.
The following operations can be performed with the flash memory:
- Installation of Windows server with express setup
- Installation of Starter Pack—the package of NEC qualified drivers and system setting
tools
- Installation of NEC ESMPRO Agent and Universal RAID Utility
- Performance of the Test and Diagnosis Tool
N8115-05
5.2.2 RDX
6 Internal Flash Memory
Available socket: 1
NEC Corporation Revision 1.0, February 2012 18
Page 19
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
LAN
1000BASE-T Adapter (2ch)
Broadcom NetXtreme II 5709 Dual port Network Interface Card
PCIe x4, LP / FH
NOTE:
Teaming and bonding features across the standard LAN and the
LAN controller are supported on Windows Server 2003R2 / 2008
/ 2008R2 and Red Hat Linux 5.x Operating system.
Up to 2 teams per system and 2 ports per team is supported in
the teaming and bonding feature.
N8104-134
Product Name / Description
Part Number
Keyboard and Mouse Pack (US)
1 x 104-keys White USB keyboard, 1 x USB White Optical Wheel Mouse
(Standard)
Product Name / Description
Part Number
Remote KVM and Media License kit
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
- Displays a graphics console on the web browser of the remote terminal
(PC/server).
- Controls keyboard and mouse via the remote terminals' web browser
Remote media:
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
N8115-04
7 PCI Card
7.1 LAN Controller
8 Other Add-in Components
8.1 Input Devices
9 Add-on Components
9.1 Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the
standard management features. For more extensive remote KVM and remote media features, choose the
following kit.
NEC Corporation Revision 1.0, February 2012 19
Page 20
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Category
Product Name / Description
Part Number
Front Bezel
Dust Proof Bezel with Sensor
Including 1 set of filter replacement sensors, 1 set of dust proof
filters
N8146-19
Filter
Dust proof filter (5 pcs.)
For N8146-19 Dust Proof filter
Removal capacity of particles : Up to 1 μm-sized
N8147-22
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-86
Category
Product Name
Drive supported
Part Number
RDX
RDX Cartridge (320GB)
N8151-86
N8152-26
RDX Cartridge (500GB)
N8151-86
N8152-27
RDX Cartridge (1TB)
N8151-86
N8152-33
DAT
DAT72(36GB) Medium 5 pack
N8151-69
N8152-08
9.2 Dust / Insect Proof Kit
The GT110d-S server supports the dust resistant feature. Choose the following kit to install the system in
dusty places..
9.3 Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
9.4 Medium and Cartridge
NEC Corporation Revision 1.0, February 2012 20
Page 21
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Standard
With Remote KVM
and Media License
kit
Hardware
monitoring
Temperature/voltage/power/
fan /degeneration (memory/hard drive)
Hardware event log collection
Boot monitoring
Booting, BIOS/POST stall, OS stall,
shutdown
Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)
Remote KVM
POST/BIOS setup, DOS utility
(via LAN)
Panic screen, Boot screen
Text-based screen (OS console)
GUI-based screen (OS console)
-
Remote control
Remote reset/power on-off/ dump
(via LAN)
Configure power capping setting
-
- Configure BIOS setting (items limited)
OS shutdown
Remote media (CD/DVD/FD)
-
Server Management Command Line
Protocol (DMTF compliant)
Remote control via Web browser
(without dedicated app)
Remote batch
Scheduling (without UPS)
Maintenance
Save/restore BIOS/BMC setting to/from a
dedicated flash memory
Others
Set automatic IP address via DNS/DHCP
Remote wakeup
Wake On LAN, Wake On Ring
Centralized
management
Monitoring and control of multiple servers
Industry standard
IPMI
2.0
2.0
References
Note for Ordering
Parts number provided may be needed to modify by country/region when you order the products.
For example, the operable parts number for N8100-1738F in EMEA is N8100-1730F-O, adding "-O", the
country-specific identifier for EMEA, after the parts number.
Please consult our sales representative for your country identifier.
Server Management
The EXPRESSSCOPE Engine 3, integrated into the GT110d-S server, provides superior remote control
and system management features listed in the table below.
NEC Corporation Revision 1.0, February 2012 21
Page 22
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
The USB interface is not guaranteed to work properly for all USB devices.
NEC Corporation Revision 1.0, February 2012 23
Page 24
CONFIGRATION GUIDE – NEC Express5800/GT110d-S / Liquid cooling model
Revision
Date
Description
1.0
February 13, 2012
Initial release
Revision History
NEC Corporation Revision 1.0, February 2012 24
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.