NEC Express5800-320Lb Upgrade Guide

Express5800/320Lb Software Notes

EXPRESSBUILDER 3.005b-G
Update Notes
Express5800/320Lb EXPRESSBUILDER 3.005b-G Update Notes Page 1 of 9
Proprietary Notice and Liability Disclaimer
The information disclosed in this document, including all designs and related materials, is the valuable property of NEC Solutions (America), Inc. and/or its licensors. NEC Solutions (America), Inc. and/or its licensors, as appropriate, reserve all patent, copyright and other proprietary rights to this document, including all design, manufacturing, reproduction, use, and sales rights thereto, except to the extent said rights are expressly granted to others.
The NEC Solutions (America), Inc. product(s) discussed in this document are warranted in accordance with the terms of the Warranty Statement accompanying each product. However, actual performance of each product is dependent upon factors such as system configuration, customer data, and operator control. Since implementation by customers of each product may vary, the suitability of specific product configurations and applications must be determined by the customer and is not warranted by NEC Solutions (America), Inc.
To allow for design and specification improvements, the information in this document is subject to change at any time, without notice. Reproduction of this document or portions thereof without prior written approval of NEC Solutions (America), Inc. is prohibited.
Trademarks
Microsoft, Windows, and Windows 2000 are registered trademarks of Microsoft Corporation. VERITAS Volume Manager is a trademark of VERITAS Software Corporation. All other trademarks and registered trademarks are the property of their respective
trademark owners.
PN: 455-01705-000 November 2003
Copyright 2003
NEC Solutions (America), Inc
10850 Gold Center Drive, Suite 200,
Rancho Cordova, CA 95670
All Rights Reserved
Express5800/320Lb EXPRESSBUILDER 3.005b-G Update Notes Page 2 of 9

Overview

This document describes the procedure to upgrade the specific drivers and software for your 320Lb (FT Control Software) to version 2.0.1. In addition to general code improvement and minor fixes, the FT Control Software 2.0.1 adds support for 1GB DIMM, ExpressCluster software and Microsoft Windows 2000 Service Pack 4. If you plan to install any of the following: 1GB DIMM memory sticks, use NEC ExpressCluster software or Microsoft Windows 2000 Service Pack 4, please upgrade your 320Lb FT Control Software to version 2.0.1

FT Control Software version 2.0.1 Upgrade Procedure for 320Lb

Prerequisites for Upgrade

A. Back up the system boot disks prior to performing this upgrade
in the event of the rare occurrence that the OS fails to start
during or after the upgrade. B. BIOS Version 3.4.1 installed. C. The 363-01639-002 EXPRESSBUILDER CD version 3.005b-G. D. Microsoft Windows 2000 Service Pack 4 CD or the Service Pack
4 executable saved on your local hard drive. E. The 455-01705-000 EXPRESSBUILDER 3.005b-G Update Notes
(this document). F. The Veritas Volume Manager 3.1 License Key. G. The 456-01675-000 Express5800/320Lb/320Lb-R User’s Guide
(available on EXPRESSBUILDER). H. 1 GB DIMMs are not installed. I. Document the Network (LAN) teaming configuration in the Intel
PROSet II utility so that they can be restored after the upgrade. J. Document the disk mirroring configuration so that it can be
restored after the upgrade, if necessary. K. Review the documentation below.

Cautions and Restrictions

a. The 320Lb may appear to hang with a blank screen when
shutting down prior to a restart. This behavior has typically
been noted when a USB to PS2 converter is used for the mouse
and/or keyboard, with or without a KVM switch. As a
workaround for this situation, remove and replace the
keyboard/mouse USB cable in the USB port. System operation
should continue after the cable is removed. b. As with any change in memory configuration under a Microsoft
Windows operating system, the paging size should be reviewed
and changed if required. c. The memory dump location in Startup and Recovery section of
System properties should be reviewed after any memory
Express5800/320Lb EXPRESSBUILDER 3.005b-G Update Notes Page 3 of 9