NEC Express5800-320Fd User Setup Information

N8800-122F/132F, EXP320J
NEC Express5800/320Fd-LR
N8800-123F/133F, EXP320K
NEC Express5800/320Fd-MR
User's Guide (Setup)
10-2008
856-127506-102-D
PROPRIETARY NOTICE AND LIABILITY DISCLAIMER
The information disclosed in this document, including all designs and related materials, is the valuable property of NEC Corporation (NEC) and /or its licensors. NEC and/or its licensors, as appropriate, reserve all patent, copyright and other proprietary rights to this document, including all design, manufacturing, reproduction, use, and sales rights thereto, except to the extent said rights are expressly granted to others.
The NEC product(s) discussed in this document are warranted in accordance with the terms of the Warranty Statement accompanying each product. However, actual performance of each such product is dependent upon factors such as system configuration, customer data, and operator control. Since implementation by customers of each product may vary, the suitability of specific product configurations and applications must be determined by the customer and is not warranted by NEC.
To allow for design and specification improvements, the information in this document is subject to change at any time, without notice. Reproduction of this document or portions thereof without prior written approval of NEC is prohibited.
Forth Printing, Oct 2008
Copyright 2008
NEC Corporation
7-1 Shiba 5-Chome, Minato-Ku
Tokyo 108-8001, Japan
All Rights Reserved
Printed in Japan
Keep this User's Guide handy for quick reference when necessary.
Safety Indications
To use NEC Express5800 series safely, follow the instructions in this User's Guide. This guide explains components that pose a danger, types of dangers caused by failing to follow the
instructions, and actions taken to prevent them; such components are labeled warning. This guide and warning labels use “WARNING” and “CAUTION” to indicate a danger dependin g on
the degree. These terms are defined as follows:
WARNING
CAUTION
This guide uses the following three types of symbols to give indications and precautions against a danger. They are defined as follows:
Indicates that there is a risk of a danger. Each image symbolizes a particular type of danger. (Attention)
Indicates what you must not do. Each image symbolizes a particular type of prohibition. (Prohibited actions)
Indicates what you must do. Each image symbolizes a particular type of action necessary to avoid a danger. (Mandatory actions)
(Example)
High temperature.
Symbol indicating a prohibited action (may not always be indicated)
Term indicating a degree of danger
Indicates a danger that could lead to a death or serious injury. Indicates a danger that could lead to a burn, other injuries or damage to
physical assets.
Symbol to draw attention
CAUTION
Immediately after the power-off, system components such as hard disk are very hot. Wait the server to cool down completely before adding/removing some component.
Description of a danger
Symbols and its descriptions used in this User’s Guide and warning labels are as follows:
Attention
Indicates a risk of an electric shock.
Indicates a risk of a personal injury due to heat.
Indicates a risk of catching your fingers.
Indicates a risk of a fire or smoke.
Indicates a general precaution or warning that is not defined herein.
Indicates a risk of losing eyesight due to laser beam.
Indicates a risk of an explosion.
Indicates a risk of a personal injury.
Prohibited actions
Indicates a general prohibition that is not defined herein.
Do no touch the indicated area. There is a risk of an electric shock or fire.
Do not touch with wet hands. There is a risk of an electric shock.
Keep from flame. There is a risk of a fire.
Avoid using water or liquid nearby. If it spills on the equipment, there is a risk of an electric shock or fire.
Do not disassemble, repair, or modify the equipment. There is a risk of an electric shock or fire.
Mandatory actions
Unplug the server. There is a risk of an electric shock or fire.
Indicates a general action to take that is not defined herein. Make sure to follow the instructions.
For detailed notes to set up the machine safely, refer to “NOTES FOR SAFE HANDLING” on page 1-2.
NOTE: Th is equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
CE Statement Warning: This is a Class A product. In residential environment, this product may cause radio
interference, in which case the user may be required to take adequate measures (EN55022).
CLASS 1 LASER PRODUCT
NOTE: This product provides resistance against hardware faults with its redundant hardware
modules. However, this does not mean complete fault-tolerance is assured. For example, there is a risk of system down when: – A fatal fault occurs in software. – Both modules within a redundant hardware pair break down. – A fatal fault occurs in a non-redundant component, such as the clock generator circuitry
or the interconnect backplane.
– The entire system is cut off from AC power.
This system is classified as a CLASS 1 LASER PRODUCT. This label id located on the internal DVD-ROM installed in your system.
安全注意事項
安全標示
請參考本用戶指南中的指示以安全使用NEC Express5800系列伺服器。
本用戶指南說明了設備何處有危險、危險類型、如何避免危險等。在設備可預計到的危險之處或其附近 貼有警告標籤。
用戶指南及警告標籤中,根據危險程度不同,使用“警告"、“注意"等詞,含義如下:
WARNING
CAUTION
對危險的提示表示有如下三種符號,具體含義如下所述:
表示該處可能發生危險。符號為危險內容的圖案。(注意)
(用戶指南中範例)
表示禁止行為。符號中或其附近的圖案為禁止行為內容。(禁止行為)
表示強制行為。符號中的圖案為強制必須做的行為內容。即為避免危險必需的行為。(強 制行為)
表示如不遵守該指示,可能引發人員傷亡。
表示如不遵守該指示,可能發生燒傷等身體損傷或造成物質損失。
注意符號
表示危險程度的用語
CAUTION
注意高溫。 本產品關閉電源後,內置硬碟等內部設備仍然處於高溫狀態。請在充分冷卻之後 進行拆裝。
禁止行為的提示符號(有可能沒 有此類提示)
危險提示內容
注意
本書及警告標籤中使用的符號
表示有觸電的危險。
表示有因高溫而負傷的危險。
表示有手指等被夾住的危險。
表示有冒煙或者著火的危險。
表示非特定的一般的提醒警告。
表示有因雷射導致失明的危險。
禁止行為
表示有爆炸的危險。
表示有受傷的危險。
表示非特定的一般禁止。
不要觸摸指定區域。有觸電或著火的危險。
不要用濕手觸摸。有觸電的危險。
遠離火源。有著火的危險。
遠離液體。如果沾到液體,有觸電或著火的危險。
請不要對本設備進行拆卸、修理、改造。有觸電和發生火災的危險。
強制行為
請將本設備的電源插頭從伺服器上拔下。有發生火災和觸電的危險。
對非特定的一般使用者的行為進行指示。請按照說明進行操作。
CLASS 1 LASER PRODUCT
注意: 本產品通過多餘的硬體模組提供硬體容錯性能。但是這並不表示能夠保證完全容錯。
如,在以下情況下可能發生宕機: – 軟體發生致命故障。 – 多餘硬體雙方均發生故障,不能運行。 – 時鐘產生器線路或內部連接背板等非多餘元件發生致命故障。 – 切斷了整個系統的AC電源
這是CLASS 1 LASER PRODUCT。該標籤貼於系統的內部光碟。
Trademarks and Patents
NEC EXPRESSBUILDER, NEC ESMPRO and DianaScope are registered trademarks of NEC Corporation.
Microsoft, Windows, Windows Server, Windows NT, and MS-DOS are registered trademarks of Microsoft Corporation in the United States and other countries.
Intel and Pentium are registered trademarks of Intel Corporation. AT is a registered trademark of International Business Machines Corporation in the United States
and other countries. Adobe, the Adobe logo, Acrobat, and the Acrobat logo are trademarks of Adobe Systems
Incorporated. Datalight is a registered trademark of Datalight, Inc. ROM-DOS is a trademark of Datalight, Inc. Xeon is a trademark of Intel Corporation in the United States. DLT and DLTtape are trademarks of
Quantum Corporation in the United States. Mozilla is a registered trademark of Mozilla Foundation. Netscape is a registered trademark of Netscape Communications Corporation in the United States
and other countries. Java is a registered trademark of Sun Microsystems, Inc in the United States and other countries.
All other product, brand, or trade names used in this publication are the trademarks or registered trademarks of their respective trademark owners.
Microsoft Windows Server 2003 R2 Standard x64 edition operating system and Microsoft Windows Server 2003 R2 Enterprise x64 Edition operating system or Microsoft Windows Server 2003 Enterprise x64 Edition operating system are called Windows Server 2003 x64 Edition for short. Microsoft Windows Server 2003 R2 32-bit Standard Edition operating system, Microsoft Windows Server 2003 R2 32-bit Enterprise Edition operating system, Microsoft Windows Server 2003 Standard Edition operating system and Microsoft Windows Server 2003 Enterprise Edition operating system are called Windows Server 2003 for short. Microsoft Windows 2000 Server operating system, Microsoft Windows 2000 Advanced Server operating system and Microsoft Windows 2000 Professional operating system are called Windows 2000 for short. Microsoft Windows Vista Business operating system is called Windows Vista for short. Microsoft Windows XP Professional x64 Edition operating system is called Windows XP x64 Edition for short. Microsoft Windows XP Home Edition operating system and Microsoft Windows XP Professional operating system are called Windows XP for short. Microsoft Windows NT Server network operating system version 3.51/4.0 and Microsoft Windows NT Workstation operating system version 3.51/4.0 are called Windows NT for short. Microsoft Windows Millennium Edition Operating System is called Windows Me for short. Microsoft Windows 98 operating system is called Windows 98 for short. Microsoft Windows 95 operating system is called Windows 95 for short. Names used with sample applications are all fictitious. They are unrelated to any existing product names, names of organi zat i ons, or individual names.
Avocent and DVC (DAMBRACKAS VIDEO COMPRESSION) are registered trademarks of Avocent US in the United States and other countries. N8815-005/006, ft remote management card, adops the DVC technology of Avocent US.
The patent numbers for the DVC technology of Avocent US. US Patent Number: 5,732,212/5,937 ,1 7 6/ 6, 63 3, 9 05/6,681,250/6,701,380 (others patents pending)
Taiwanese Patent Number: 173784 European Patent Number: 0 740 811
Notes:
(1) No part of this manual may be reproduced in any form without prior written permission of
NEC Corporation. (2) The contents of this manual are subject to change without prior notice. (3) The contents of this manual shall not be copied or altered without prior written permission of
NEC Corporation. (4) All efforts have been made to ensure the accuracy of all information in this manual. If you find
any part unclear, incorrect, or omitted in this manual, contact the sales agent where you
purchased this product. (5) NEC assumes no liability arising from the use of this product, nor any liability for incidental or
consequential damage arising from the use of this manual regardless of (4) above.
© NEC Corporation 2008
ii
Preface
Welcome to the NEC Express5800/ft series. NEC Express5800/ft series is a “fault-tolerant (ft)” server focusing on “high reliability” in terms of
fault-tolerance, in addition to “high performance,” “scalability,” and “general versatility” provided by NEC Express5800 series. In the event of trouble, its dual configuration will allow the system to instantaneously isolate the failed parts to assure non-stop running; operation will be moved smoothly from one module to the other, minimizing damage to it. You can use NEC Express5800/ft series in a mission-critical system where high availability is required. By the use of Windows Server 2003 operating system, it also provides outstanding openness for general-purpose applications, etc.
To make the best use of these features, read this User's Guide thoroughly to understand how to operate NEC Express5800/ft series.
開始
這次,請購買敝社的 Express5800/ft 服務器,實在謝謝。 Express5800/ft 服務器系列 Express5800 系列的「高性能」,是「擴展性」,「通用性」的特長之
外又加上,考慮與耐故障性出色的「高(貴)的可靠性」,被開發了的「Fault Tolerant 服務器」。 在要求是把向從不給予由於在萬一障礙的發生中根據也雙重化,把障礙地方做為瞬間割開的 事業務影響繼續做動作,一邊的組件已經一方的組件業務交待順暢地進行,業務給予的損壞 做為最小限度控制住的事可能的系統的本裝置,高(貴)的可用性的基幹業務中也可以放心使用。 同時,根據 Windows 操作系統的採用,能適用通用應用軟件等,開放性也出色。 為了到最大限度拉出本裝置有的機能,很好地變成為變成使用之前正式文本為念,充分地裝 置的對待也請理解。
About This User’s Guide
This User's Guide helps a user to properly setup and use the product. Consult this guide when you set up the product.
Keep this manual and the separate volume of User’s Guide handy. This User's Guide is intended for users who have a good kn owl edge on the basic use of Windows
operating systems and general I/O devices such as a keyboard and mouse.
How to Use This User's Guide
This guide explains the procedures you should perform before you begin system operation after you purchased the product. Read the guide in order from Chapter 1. If you perform procedures according to this guide, you will set up the product properly.
Chapter 4 describes how to install the operating system. Chapter 5 describes post-installa ti on procedures. Chapter 6 explains how to troubleshoot if you cannot set up the product properly. Refer to “SYSTEM REPAIR” on page 6-2 for details about system configurations and repairs of this product. Refer to “TROUBLESHOOTING” on page 6-13 if you feel you failed to set up the product.
iii
See this User’s Guide for details of this product’s operation, and functions and operations of the hardware and the system.
Additional Symbols
The following symbols are used throughout this User's Guide in addition to the caution symbols described at the beginning.
IMPORTANT: CHECK:
TIPS:
Important points or instructions to keep in mind when using the server or software
Something you need to make sure when using the server or software
Helpful information, something useful to know
About our Web Service
Information on NEC Express5800/ft series including modification modules is also available on our web site, NEC Express5800 Web Site Asia Pacific:
http://www.nec.co.jp/express/index.html
iv
關於正式文本
使正式文本,是為了確實安裝本裝置,能使用的輔導。進行安裝的時候請利用。使正式文本 及另冊的用指南請經常放置在實體旁邊無論什麼時候能看。
正式文本,作為所的關於 Windows 等的操作系統和鍵盤,鼠標的一般的輸入輸出設備等的 基本的處理有了充分的知識的用對象被記載。
正式文本讀方法
正式文本,本裝置的購買後,關於到能為止的系統的運用次序明著。如果做從 1 章順序讀, 隨著被記載的明的操作,確實能安裝本裝置。4 章,如果把安裝被本裝置編入的操作系統與 (第一次把電源做為 ON的時候的安裝次序)重新重新安裝操作系統的重新安裝(OS 的時候的安 裝次序)分成購買的時候明著。安裝的目的合起讀請分開。5 章,明著對安裝完成後必要 的各種工作的次序。還 6 章「故障嗎?想的時候」那麼,不能很好地安裝的情況的應對方法 被記載。本裝置的系統設定和有關修復的信息「系統的修復」(6-2 頁),「安裝失敗了嗎?如果 有」隨心的事,請看「故障找」(6-15 頁)。再者,卷末有索引。按照必要請有效的利用。
本裝置的運用和硬件及系統具體的機能·操作的說明請參照另冊的用戶指南。
關於本文中的記號
除了正式文本卷頭表現了的安全有關的注意記號以外使用著 3 種記號。變成這些的記號和意 義為理解,請確實處理裝置。
重要: 檢查:
使用服務器或者軟件的時候預先記的重要的要點又指示
需要你服務器或者使用軟件的時候,確實做(製作)的什麼
暗示:
有用的信息,暗示
關於正式文本的再購買
如果被遺失了正式文本,最近的銷售店,或購買的銷售店請諮詢。能從用指南,和添加的 光碟收納的在線文獻的一部分,下面的主頁下載。
Contents
Preface..................................................................................................................................ii
v
開始........................................................................................................................................ii
About This User’s Guide....................................................................................................iii
How to Use This User's Guide.......................................................................................... iii
Additional Symbols........................................................................................................... iii
About our Web Service..................................................................................................... iii
關於正式文本........................................................................................................................iv
正式文本讀方法 ................................................................................................................iv
關於本文中的記號............................................................................................................. iv
關於正式文本的再購買......................................................................................................iv
CHAPTER 1 BEFORE USING........................................................................................1-1
在使用前 .............................................................................................................................1-2
NOTES FOR SAFE HANDLING........................................................................................1-3
Warning Label ................................................................................................................1-3
為了把有為了安全對待的注 ................................................................................................1-4
關於警告標籤 …………………………………………….………………………………….. 1-4
PRECAUTIONS FOR SAFETY..........................................................................................1-5
General...........................................................................................................................1-5
Use of Power Supply and Power Cord...........................................................................1-6
Installation, Relocation, Storage and Connection..........................................................1-7
Cleaning and Handling of Internal Devices....................................................................1-8
During Operation............................................................................................................1-9
Rack-mount Model .......................................................................................................1-10
安全注意事項................................................................................................................................1-12
一般注意事項...........................................................................................................................1-12
使用電源及電源線注意事項 ...................................................................................................1-13
安裝,移動,保管及連接注意事項 .......................................................................................1-15
整理及操作內部設備時的注意事項 .......................................................................................1-17
操作注意事項...........................................................................................................................1-18
機架式伺服器的注意事項.......................................................................................................1-19
vi
UNPACKAGING.............................................................................................................. 1-20
Accessories.................................................................................................................. 1-20
確認箱子的內容的........................................................................................................................1-21
關於附屬品本….........................................................................................................................1-21
CHAPTER 2 ABOUT OPERATING SYSTEM................................................................ 2-1
INSTALLING Windows Server 2003 x64 Editions/ Windows Server 2003 ................. 2-2
About OS Installation..................................................................................................... 2-2
CHAPTER 3 INSTALLING SERVER..............................................................................3-1
INSTALLATION................................................................................................................. 3-2
Rack-mount Model......................................................................................................... 3-2
Installing the device to the rack (N8140-74/92/93/94/98/99)......................................... 3-5
Unmounting the device from the rack (N8140-74/92/93/94/98/99) ............................. 3-12
INSTALLING the Tower Conversion Kit (N8843-002)................................................. 3-13
Connect peripheral devices to NEC Express5800/ft series....................................... 3-18
CHAPTER 4 WINDOWS SETUP.................................................................................... 4-1
SETUP FLOW ................................................................................................................... 4-3
Step 1: Procedure to Install and Reinstall OS .............................................................. 4-4
Size of the Partition to be Created................................................................................. 4-6
Step 2: Prepare for Express Setup................................................................................. 4-8
2-1: Prepare NEC Express5800/ft series ...................................................................... 4-8
Step 3: Disable OS Boot Monitoring Function............................................................ 4-10
Step 4A : Start Express Setup...................................................................................... 4-16
Flow of Setup Procedures ........................................................................................... 4-17
Setup Procedures........................................................................................................ 4-18
Step 4B: Manual Setup.................................................................................................. 4-25
Preparing to Install....................................................................................................... 4-25
Installing Windows....................................................................................................... 4-27
Changing Drive Letters................................................................................................ 4-30
Step 5: Windows Server 2003 Service Pack Installation........................................... 4-31
vii
Step 6: Set Duplex LAN Configuration.........................................................................4-31
Overview.......................................................................................................................4-31
NEC Express5800/ft Series Duplication Rule ..............................................................4-33
Duplex Configuration Setup..........................................................................................4-33
Step 7: Set Dual Disk Configuration.............................................................................4-38
Setting Dual Disk Configuration by RDR (Rapid Disk Resync) function......................4-38
Step 8: Update Software................................................................................................4-45
Step 9: Connect and Configure Options......................................................................4-46
Step 10: Create Volume .................................................................................................4-47
Step 11: Set Network for NEC ESMPRO Agent ...........................................................4-48
Step 12: Enable OS Boot Monitoring Function ...........................................................4-50
Step 13: Make Settings for Failure Management ........................................................4-51
Set Memory Dump (Debug Information) ......................................................................4-51
Set Dr. Watson.............................................................................................................4-57
Install a Network Monitor..............................................................................................4-58
Set Recovery Console..................................................................................................4-59
Step 15: Back up System Information..........................................................................4-60
CHAPTER 5 PROCEDURES AFTER COMPLETION OF INSTALLATION...................5-1
INSTALLING MANAGEMENT UTILITIES.........................................................................5-2
Updating the System......................................................................................................5-2
NEC ESMPRO Agent.....................................................................................................5-3
NEC ESMPRO Manager..............................................................................................5-12
CONFIRMING THE ft Server Control Software VERSION...........................................5-13
APPLYING Windows Service Pack...............................................................................5-14
Notes to apply the Windows Service Pack...................................................................5-14
Applying Windows Service Pack..................................................................................5-14
COMPRESSING A SYSTEM DRIVE...............................................................................5-15
ABOUT Windows Update (APLYING SECURITY PATCHES)......................................5-15
CHAPTER 6 TROUBLESHOOTING...............................................................................6-1
SYSTEM REPAIR ..............................................................................................................6-2
Preparation.....................................................................................................................6-4
Starting up Recovery Console........................................................................................6-5
Updating the System......................................................................................................6-9
viii
Installing ft Server Control Software............................................................................ 6-13
TROUBLESHOOTING .................................................................................................... 6-15
Problems with NEC EXPRESSBUILDER.................................................................... 6-15
Problems with Windows Setup.................................................................................... 6-16
Problems with Express Setup...................................................................................... 6-18
Problems with NEC ESMPRO Setup........................................................................... 6-19
Problems with System Repair...................................................................................... 6-20
APPENDIX A ABOUT SERVICES .................................................................................A-1
Chapter 1
Before Using
This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go through this chapter before you start setup of the product.
1-2 Before Using
在使用前
為了把本裝置做為安全確實變成使用必要的關於信息,實體及附屬品等記載著。在安裝實體之前,必定 請讀。同時,關於本文中的名稱請參照用指南的「與各部分的名稱功能」的項
Before Using 1-3
NOTES FOR SAFE HANDLING
The following section describes necessary information to use the product properly and safely.
Warning Label
Warning label is placed in the certain part of the system so that the user stays alert to possible risks. Do not remove or damage the label.
If this label is missing, about to peel off, or illegible, contact your sales agent. The figures below show the location of this label on the server.
Front of Device
1-4 Before Using
為了把有為了安全對待的注
意的本裝置做為安全確實變成使用必要的信息被記載。
關於警告標籤
隱藏實體內的危險性的零部件和那個週邊警告標籤被粘貼。這個是為了請操縱本裝置的時候,
經常在顧客裡(上)認識能考慮的危險性的東西(揭下標籤,請別弄髒)。如果這個標籤沒被粘貼,
剝落懸掛著,髒等做不能辨認的時候購買的銷售店請聯絡。
對以下表現被本產品粘貼的標籤的位置。
設備前部
Before Using 1-5
PRECAUTIONS FOR SAFETY
This section provides precautions for using the server safely. Read this section carefully to ensure proper and safe use of the server. For symbol meanings, see “Safety Indications” described in the previous section.
General
Do not use the server in an operation where human lives ar e invo lved or hi gh reliab ilit y is required.
This equipment is not intended for use in controlling or use with facilities or systems where human lives are involved or high reliability is required, including medical devices or nuclear, aerospace, transportation, and traffic control facilities. NEC assumes no liability for any accidents or damage to physical assets resulting from the use of this equipment in such systems or facilities.
Do not continue to use the server if you detect smoke, odor, or noise. If the server emits smoke, odor, or noise, immediately flip off the POWER switch,
unplug the cords, and contact your sales agent. There is a risk of a fire.
Do not insert a wire or metal object. Do not insert a wire or metal objects into a vent or disk drive slot. There is a risk of an
electric shock.
Prevent water or foreign objects from getting into the server. Do not let water or foreign objects (e.g., pins or paper clips) enter the server. There is
a risk of a fire, electric shock, and breakdown. When such things acci dentall y enter the server, immediately turn off the power and unplug the cords. Contact your sales agent instead of trying to disassemble it yourself.
WARNING
CAUTION
1-6 Before Using
Use of Power Supply and Power Cord
WARNING
Do not handle power plugs with a wet hand. Do not plug/unplug power cords with a wet hand. There is a risk of an electric shock.
Do not connect the ground wire to a gas pipe. Never connect the ground wire to a gas pipe. There is a risk of a gas explosion.
CAUTION
Do not plug the cords in nonconforming outlets. Use wall outlets with specified voltage and power type. There is a risk of a fire or
current leakage. Avoid installing the server where you may need extension cords. If the cords do not
meet the power specifications, there is a risk of overheating that could lead to a fire.
Do not plug too many cords in a single outlet. If the rated current is exceeded, there is a risk of overheating that could lead to a fire.
Do not plug the cords insecurely. Insert the plug firmly into an outlet. There is a risk of heat or fire due to poor contact. If
dust settles on the slots and it absorbs moisture, there is also a risk of heat or fire.
Do not use nonconforming power cords.
AC cord is to spend the thing of the next specifications: You also have to observe the following prohibitions to prevent an electric shock or fire
caused by damage to the cords. Do not pull on the cords. Do not pinch the cords. Do not bend the cords. Keep chemicals away from the cords. Do not twist the cords. Do not place any object on the cords. Do not use cords as bundled. Do not alter, modify, or repair the cords. Do not staple the cords. Do not use any damaged cord. (Replace it with a new one of the same specifications . For replacement procedures, contact your sales agent.)
Installation, Relocation, Storage and Connection
Do not install the server in an unsuitable place. Install the server in such a place as specified in this User's Guide. Avoid the
following locations. There is a risk of a fire.
a dusty place a humid place located near a boiler, etc a place exposed to direct sunlight an unstable place
Do not use or store this product in a corrosive environment. Avoid the usage or storage of this product in an environment which may be
exposed to corrosive gases, such as those including but not limited to : sulfur dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, ammonia and/or ozone. Avoid installing NEC Express5800/ft series in a dusty environment or one that may be exposed to corrosive materials such as sodium chloride and/or sulfur. Avoid installing this product in an environment that may have excessive metal flakes or conductive particles in the air. Such environments may cause corrosion or short circuits within this product, resulting in not only damage to this product, but may even lead to be a fire hazard. If there are any concerns regarding the environment at the planned site of installation or storage, please contact your sales agent.
Do not use any non-designated interface cable. Use only interface cables designated by NEC; identify which component or
connector to attach beforehand. If you use a wrong cable or make a wrong connection, there is a risk of short-circuit that could lead to a fire.
You also have to observe the following prohibitions about handling and connecting interface cables:
Do not use any damaged cable connector. Do not step on the cable. Do not place any object on the cable. Do not use the server with loose cable connections. Do not use damaged cables.
CAUTION
Before Using 1-7
1-8 Before Using
Cleaning and Handling of Internal Devices
WARNING
Do not disassemble, repair, or alter the server. Unless described herein, never attempt to disassemble, repair, or alter the server.
There is a risk of an electric shock or fire as well as malfunction.
Do not look into the DVD-ROM drive. The DVD-ROM drive uses a laser beam. Do not look or insert a mirror inside while the
system is on. A laser beam is invisible; if your eyes get exposed to it, there is a risk of losing eyesight.
Do not detach a lithium battery yourself. This equipment has a lithium battery. Do not detach it yourself. If the battery is
exposed to fire or water, it could explode. When the lithium battery is running down and the server does not work correctly, contact your sales agent instead of disassembling, replacing or recharging it yourself.
Disconnect the power plugs before cleaning the server. Even though built-in options for the server can be replaced while the power cords are
connected to power source, be sure to follow the instructions described in this User’s Guide. Do not touch any internal device of the server unless instructed by this User ’s Guide. There is a risk of an electric shock. Make sure to power off the server and disconnect the power plug from a power outlet before cleaning or installing/removing internal optional devices. Touching any internal device of the server with its power cords connected to power source may cause an electric shock even if the server is off-powered. Disconnect the power plug from the outlet occasionally and clean the p lug with a dry cloth. Heat will be generated if condensation is formed on a dust y plug, which may cause a fire.
CAUTION
High temperature Immediately after powering off the system, system components such as hard disk may
be very hot. Wait for the server to cool down completely before adding/removing components.
Make sure to completely insert cables and boards. Completely insert all power cords, interface cables and/or boards. An incompletely
inserted component may cause a contact failure, resulting in fire and/or smoke.
Protect the unused connectors with the protective cap. The unused power cord connectors are covered with the protective cap to prevent
short circuits and electrical hazards. When removing the power cord connector from the internal devices, attach the protective cap to the connector. Failure to follow this warning may cause a fire or an electric shock.
During Operation
Keep animals away. Keep animals away from the server. Animal’s waste or hair may get inside the server
to cause a fire or electric shock.
Do not place any object on top of the server. The object may fall off to cause injuries, damage to hardware and/or a fire.
Do not leave the DVD tray ejected. Dust may get in the server to cause malfunction. The ejected tray may also become a
cause of injuries.
Do not touch the server when it thunders. Unplug the server when it threatens to thunder. If it starts to thunder before you unplug
the server, do not touch the server or cables. There is a risk of a fire or electric shock.
CAUTION
CAUTION
Before Using 1-9
1-10 Before Using
Rack-mount Model
Do not install the server on a nonconforming rack. Install the server on a 19-inch rack conforming to the EIA standard. Do not use the
server without a rack or install it on a nonconforming rack. The server may not function properly, and there is a risk of damage to physical assets or injuries. For suitable racks, contact your sales agent.
Do not use the server in an unsuitable place. Do not install a server rack in an unsuitable environment.
Other systems also may be affected, and the rack may fall over to cause a fire or injuries. For details about installation environment and quake-resistant engineering, see the attached manual or contact your sales agent.
Be careful not to hurt your fingers. Exercise great care not to hurt your fingers on the rail when you m ount/dismount the
server into/from the rack.
Carry or install the server by more than 3 people. To avoid a risk of injuries, users should not attempt to carry or install the server into a
rack. Installation should be performed by trained maintenance personnel.
Do not install the server in such a manner that its weight is imposed on a single place. To distribute the weight, use stabilizers or attach two or more racks. Unstable rack
may fall down to cause injuries.
Do not assemble parts alone. It takes at least two people to mount doors and trays to a rack. If you handle them
alone, you may drop some parts to cause a breakage or injuries.
Do not pull a device out of the rack if the rack is unstable. Before pulling out a device, make sure that the rack is fixed (by stabilizers or
quake-resistant engineering).
Do not leave more than one device pulled out from the rack. If you pull out more than one device, the rack may fall down. You can only pull out one
device at a time.
WARNING
CAUTION
Before Using 1-11
CAUTION
Do not install excessive wiring. To prevent burns, fires, and d amage to the server, make sure that the rated load of the
power branch circuit is not exceeded. For more information on installation and wiring of power-related facilities, contact your electrician or local power company.
Do not pull out a device during operation. Do not pull out or remove a device while it is running. T here is a risk of malfunction
and a device may be detached from a rack to cause injuries.
1-12 Before Using
安全注意事項
本節講述安全使用本伺服器所需的注意事項。為了您正確安全地使用本伺服器,請仔細閱讀該節內容。 符號的相關說明請參考“安全標示(SAFETY INDICATIONS)"說明。
一般注意事項
WARNING
不要用於危及人命和需要高度可靠性的操作上。
本產品不要安裝在醫療設備、原子能設備、航空宇宙機器、運輸設備等會危及人 命以及需要高度可靠性的設備和機器上,也不要使用本產品來控制這些機器。如 果將本產品用於這類系統的設備及機器,造成人身事故及財產損失等後果,本公 司概不負責。
發生冒煙、異味、雜音時不要使用。 發生冒煙、異味、雜音等時,請直接關閉電源POWER,並將電源插頭從插座上拔
下。然後請與經銷商或維護服務公司聯繫。繼續使用會導致火災。
不要插入鐵絲和金屬片。
不要將金屬片和鐵絲等異物插入通氣孔或軟碟機、光碟機的縫隙。有觸電的危險。
在海外不使用。
本裝置,是日本國內專用的裝置。在海外不能使用。在海外使用這個裝置的話成 為火災和觸電的原因。
設備內不要進水和異物。
設備內不要進入水、針、夾子等異物。有可能導致火災和觸電。一旦進入異物, 請立即關閉電源,將電源插頭從插座上拔下來。不要自行拆卸,請與經銷商或維 護服務公司聯繫。
CAUTION
使用電源及電源線注意事項
不要用濕手拿電源插頭。
不要用濕手插拔電源插頭。有觸電的危險。
不要把地線連接到煤氣管道上。
請勿將地線連接到煤氣管道上。有導致煤氣爆炸的危險。
不要插入未指定的插座。
電源請使用指定電壓及電源的壁式插座。使用未指定的電源會造成火災和漏電。 請避免使用延長線安裝設備。如果連接與本產品電源規格不相符的電線,會因過 熱而導致火災。
不要在一個插座上插接多個電源線。
插座如果超過額定電流,會因過熱而導致火災的危險。
不要只插入一半。
請將電源插頭直插到底部。如果插入一半會因接觸不良而發熱,造成火災。另外, 插入部如附著灰塵、水滴等,會因發熱導致火災。
不要使用未指定的電源線。 請使用下列規格的AC電源線。
此外,操作和連接電源線時請遵循以下注意事項。
不要拖拽電源線。 不要夾電源線。 不要彎折電源線。 不要使電源線靠近化學藥品。 不要扭曲電源線。 不要在電源線上載入物品。 不要捆綁電源線。 不要對電源線進行改造、加工、修復。 不要用固定器等固定電源線。 不要使用損傷的電源線。(損傷的電源線要立即更換為相同規格的電源線。更
換事宜請與經銷商或維護服務公司聯繫)
WARNING
CAUTION
Before Using 1-13
1-14 Before Using
3極點用的電源插座以外不使用。
被本裝置添加的電源編碼拿第3大頭針(earth pin)的3極點插頭被裝備。這個插 頭,只 3極點用的電源插座能使用。使用那個以外的電源插座的話,有觸電的可能。 其他的裝置和用途不使用添加的電源編碼
添加的電源編碼作為目的被設計連接到本裝置,使用的事,那個安全性被確認。 請別絕對其他的裝置和用途使用。有成為火災和觸電的原因的可能。
安裝,移動,保管及連接注意事項
不要安裝或存放在未指定的場所。
不要將本設備放置在如下場所和本書未指定的場所,有導致火災的危險。
灰塵較多的場所 熱水器旁等濕氣較高的場所 陽光直射的場所 不平穩的場所
不要在腐蝕性環境中使用或存放設備。
不要在有腐蝕性氣體(如二氧化硫、氫化硫、氮、氫、氨或臭氧等)的環境中使 用或存放本產品。 不要將本產品安裝在灰塵較多或含有腐蝕性物質如氯化鈉或硫磺等的地方。 不要將本產品安裝在空氣中含有過量金屬碎末或傳導粒子的地方。 上述環境可能導致本產品腐蝕或短路,因而損壞產品,甚至引起火災。 對產品安裝或存放環境有任何疑問,請與經銷商或維修服務公司聯繫。
CAUTION
Before Using 1-15
1-16 Before Using
CAUTION
不要使用未指定的信號線。
使用NEC指定的信號線,並在確認連接設備和介面後進行連接。使用未指定信號 線或連接錯誤等會造成短路、導致火災。 信號線的操作和連接,須遵守以下注意事項:
不要使用任何損壞的信號線接頭。 不要踩踏信號線。 不要在信號線上載入物品。 信號線接鬆動時不要使用。
不要使用任何損壞的信號線。
整理及操作內部設備時的注意事項
不要自行拆卸、修理或改造本伺服器。
除本書記載的情況外,不要進行拆卸、修理、改造。否則,不但可能導致設備不 能進行正常運行,還有發生觸電和火災的危險。
不要看光碟機內部。
光碟機使用了雷射,請不要在電源打開的狀態下觀看內部或插入鏡子等。雷射射 射入眼睛有導致失明的危險(雷射肉眼看不見)。
不要擅自拆除鋰電池。
本產品內部安裝有鋰電池。請不要拆下電池。鋰電池靠近火或浸水均有可能發生 爆炸。
由於電池使用期限而導致設備不能正常運行時,不要自行拆卸、更換、充電等, 請與經銷商或維護服務公司聯繫。
清潔伺服器前請拔下電源插座。
整理或拆裝本設備內部的選購配置時,要切斷設備電源,並拔下電源插頭。即使 已關閉電源,但連接著電源線,接觸到任何內部設備也有觸電的危險。
另外,請經常拔下電源插頭,用乾布擦拭灰塵和附著物。有灰塵或水滴等附著時 會發熱,有導致火災的危險。
WARNING
Before Using 1-17
注意高溫
本產品關閉電源後,內置硬碟等內部設備仍然處於高溫狀態。請在充分冷卻之後 進行拆裝。
確認安裝完畢。
電源線和信號線、配件板要確實安裝妥當。 安裝不牢有可能引起接觸不良,可能造成冒煙和著火。
CAUTION
1-18 Before Using
操作注意事項
CAUTION
請用保護蓋保護好未使用的介面。
請用保護蓋保護好未使用的電源線介面以防止短路或觸電。從內部設備上拔下電 源插頭時,用保護蓋蓋好介面,否則有導致火災或觸電的危險。
CAUTION
不要在打雷時觸摸機器。
打雷時請拔下電源插頭。如來不及拔下電源插頭,請不要觸摸設備及線纜等,防 止發生火災或觸電。
不要讓寵物靠近。
寵物的排泄物和毛髮進入設備可能導致火災和觸電。
設備上不要放置物品。
物品倒下可能引起傷亡,破壞硬體或導致火災。
不要將光碟機托盤拉出放置。
防止托盤中進入灰塵引起運轉錯誤。同時防止因碰撞等造成托盤損傷。
機架式伺服器的注意事項
Before Using 1-19
不要將設備安裝在未指定的機架上。 請將設備安裝在符合EIA標準的19英寸機架上。一定要將設備安裝在指定的機架上
才能使用。否則設備可能無法正常使用,並有可能損壞機器零部件或導致人身傷 害。關於合適的機架,請與您的經銷商聯繫。
請不要自行安裝本設備。
為了避免人身傷害,請不要自行將本機器安裝到機架上。應該由受過專業訓練的 維護人員來安裝。
安裝機器時不能將機器的所有重量由一個地方來承載。
為了分散重量,應該加裝固定器或者同時安裝兩個或更多的機架,否則機架可能 會傾倒導致人身傷害。
不要擅自組裝零部件。
將前門和托架安裝到機架上至少需要兩人共同完成,否則可能會因為零部件跌落 而導致損壞或者人身傷害。
不要從不牢固的機架中抽出設備。
在抽出設備之前請確認機架已經被穩固器或者通過抗震技術固定。
不要從機架抽出兩個或者兩個以上的設備。
同時抽出兩個或者兩個以上的設備可能導致機架傾倒。一次只能抽出一個設備。
不要裝配過多電線。
為了避免火災和設備損壞,請務必確保不要超過線路的額定負載。有關電力設備 的安裝和電線的更多資訊請聯繫電工或者當地的電力公司。
請小心不要夾住或碰傷手指。
將本機器安裝到機架上或者從機架上卸載的時候,請務必小心以免被滑軌劃傷手 指。 一個人不做搬送·設置
架的搬送·設置請以3人以上去。架倒下成為傷和周圍的破損的原因。特別有高度的 架(44U架等)對不穩定的狀態有根據穩定器等沒被固定的時候。必定以3人以上一 邊支撐架一邊請做搬送·設置。
CAUTION
<僅供維護人員閱讀>
1-20 Before Using
UNPACKAGING
This product and various accessories are in the special shipping box. Take them out from the box and check the individual items. Store the box and unused accessories in a safe place.
Accessories
This product is shipped with various accessories. See the packing list to make sure everything is included and check the individual items. If any component is missing or damaged, contact your sales agent.
Keep the accessories in a safe place. You will need them when you perform setup,
addition of options, or replacement of failed components.
To check NEC EXPRESSBUILDER components, see the attached list. Be sure to fill out and mail the software registration card that is shipped with the
operating system.
Make backup copies of included floppy disks, if any. Keep the original disks as the
master disks; use these copies in operation.
Improper use of an included floppy disk or DVD may alter your system environment. If
you find something unclear, stop using them and contact your sales agent.
Before Using 1-21
確認箱子的內容的
本產品和附屬品進入著專用的捆包箱子。從箱子取出各自檢點。捆包箱子和有餘了的附屬品請最後一幕
關於附屬品本
保管。
關於附屬品本
產品的捆包箱子的其中,對實體以外種種的附屬品進入著。確認參照添加的構成品表全部齊(整) 的事,請各自檢查。萬一不足的如果有東西和損傷的東西,請與購買的銷售店聯繫。
附屬品因為到做安裝的時候和選擇的增設,本裝置出現故障了的時候必要最後一幕請保管。 關於附屬品的「EXPRESSBUILDER」的構成品,請參照包裝中有的構成品表。 操作系統添加的軟件登記卡,請所定事項記入之後,必定投進郵筒。 如果軟盤被添加,請採用軟盤的接應。同時,作為 master disc 最後一幕保管添加的軟盤,請
使用備份盤。
附屬的軟盤再光碟機,有在使用方法上犯錯誤的話變更了顧客的系統環境的可能。如果關於
使用有不明的點,不做困難的操作請對購買的銷售店,或保守服務公司詢問。
1-22 Before Using
(This page is intentionally left blank.)
Chapter 2
About Operating System
This chapter gives essential information on the Windows system supported by the server and how to install it.
2-2 About Operating System
INSTALLING Windows Server 2003 x64 Editions/ Windows Server 2003
For installing an operating system on NEC Express5800/ft series, refer to the below description.
IMPORTANT:
The NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
Before performing the NEC EXPRESS5800/ft series setup, contact your sales agent about the latest release of ft Server Control Software.
About OS Installation
Read the notes here carefully before installing the operating system.
Operating System Supported by the NEC Express5800/ft series
The operating system that NEC Express5800/ft series supports is as follows:
- Microsoft® Windows Server
“Windows Server 2003 x64 Editions.”
For more information on how to install Windows Server 2003 x64 Editions, refer to “Manual Setup.”
- Microsoft® Windows Server
called “Windows Server 2003.”
For more information on how to install Windows Server 2003, refer to “Express Setup.”
NEC Express5800/ft series does not support any operating systems other than the above (e.g., Windows Server 2003 Standard Edition, Windows 2000 or Windows NT 4.0).
TM
2003 R2 Enterprise x64 Edition (English), hereafter called
TM
2003 R2 32-bit Enterprise Edition (English), hereafter
About Operating System 2-3
About Windows Server 2003
Use the Express Setup program to install Windows Server 2003. Note the following at installation:
IMPORTANT:
Complete all the setups such as the memory expansion and the BIOS setting before
installing Wind ows Server 2003.
NEC software package, which is to be purchased separately, is also provided with the
documentation for installation. However, see this User's Guide for installation into this server.
After completing the Express Setup program, make settings for failure management (e.g.,
memory dump (debug information) setting) according to Chapter 4.
The Express Setup is only applicable to Windows Server 2003; “Manual Setup” is
applicable to Windows Server 2003 x64 Editions. “Manual Setup” allows you to manually and individually install Windows Server 2003 x64 Editions, disk drivers and other utilities.
About Auto Installation of Utilities
The Express Setup installs the following utilities automatically.
Drivers and services for achieving duplicated operation NEC ESMPRO Agent
The Express Setup program is exclusively used for the NEC Express5800/ft series. To execute the setup program, simply select the item [Express Setup] from the menu displayed when starting the system through the provided “NEC EXPRESSBUILDER.” The setup program automatically performs the complete setups from hardware internal parameter/status settings to installation of the operating system (Windows Server 2003) and various utilities.
Use the NEC Express5800/ft series setup program for the first installation and reinstallation of the operating system. This program accomplishes complicate setups.
2-4 About Operating System
(This page is intentionally left blank.)
Chapter 3
Installing Server
This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express5800/ft series ready for use, and ho w t o connect pe ripherals.
3-2 Installing Server
y
r
INSTALLATION
This section describes installation of NEC Express5800/ft series.
Rack-mount Model
You can mount NEC Express5800/ft series on a rack that conforms to the EIA standards.
IMPORTANT:
NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
Installing a rack
To install a rack, see the instruction that comes with the rack, or contact your sales agent or maintenance personnel.
A room that can maintain the following
conditions:
[When operating]
Temperature: 10 to 35ºC*
Humidity: 20 to 80%
Temperature gradient: ±10ºC/hr
Atmospheric pressure: 749 to 1040hpa
[When not operating]
Temperature: 5 to 40ºC*
Humidity: 10 to 80%
Temperature gradient: ±15ºC/hr
Atmospheric pressure: 749 to 1040hpa
100V - 127 V or 200V - 240 V parallel bi-polar power outlet with grounding
Wall outlet within the reach of supplied power cord.
Level and reinforced floor.
* It is recommended to use the server in a room where
temperature can be kept between 15 and 25ºC.
Space 40 cm or more on top, 1 m or more on the front and rear, and 60 cm or more on the right and left.
Place where the rack is stabilized b
the stabilize
Installing Server 3-3
Observe the following precautions to use the server safely. There is a risk of a death or serious injury. For details, see “Notes for Safe Handling” in Chapter 1.
WARNING
Do not install the server in non-designated places. Do not connect the ground wire to a gas pipe.
Observe the following precautions to use the server safely. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling“ in Chapter 1.
Do not carry or install a rack alone. Do not install a rack in such a manner that its weight is imposed on a single
place.
Do not assemble or disassemble parts alone. Do not pull a device out of the rack if the rack is unstable. Do not leave more than one device pulled out from the rack. Do not install excessive wiring.
CAUTION
Do not install NEC Express5800/ft series in such places as listed below. If you locate racks or install the server in such places, the server may malfunction.
Place where you cannot pull out the components fully. Place that cannot sustain the total weight of the rack and its components. Place where you cannot use stabilizers or where you cannot perform installation without
quake-resistant engineering.
Place whose floor is uneven or inclined. Place where temperatures change widely (near a heater, an air conditioner, or a refrigerator). Place that is subject to intense vibration. Place where corrosive gas (sodium chloride, sulfur dioxide, hydrogen sulfide, nitrogen
dioxide, or ozone) is generated, or a place that is close to chemicals or exposed to chemicals.
Place whose floor is covered with non-antistatic carpet. Place that may be subject to falling objects. Place that is close to some equipment that generates intense magnetic field (e.g., TV set,
radio, broadcasting/communications antenna, power transmission wire, and electromagnetic crane). (If unavoidable, contact your sales agent to request proper shield construction.)
Place where the power cords of the server must be connected to outlets that share the outlet
of another device with large power consumption.
3-4 Installing Server
Place that is close to some equipment that causes power noises (e.g., sparks caused by
power-on/off using a relay). If you must install the server close to such equipment, request your sales agent for separate power cabling or noise filter installation.
Installing Server 3-5
Installing the device to the rack (N8140-74/92/93/94/98/99)
Install this device to the rack. Installing the device to our company’s racks (N8140-74/92/93/94/98/99) or to other company’s
racks is explained in this section.
Observe the following precautions to use the server safely. There is a risk of a death or serious injury. For details, see “Notes for Safe Handling“ in Chapter 1.
Do not use the product with the unspecified rack. Do not use the product at non-designated places.
Observe the following precautions to use the server safely. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling“ in Chapter 1.
Do not install or remove a rack alone. Do not install the server with the cover removed. Do not squeeze your fingers in the product.
IMPORTANT:
Temperature increase inside the rack and airflow
WARNING
CAUTION
If you install several components or the ventilation isn’t good inside the rack, the internal temperature may increase due to heat emitted from the components. When the operating temperatures of NEC Express5800/ft series (10 to 35°C) are exceeded, there is a risk of malfunction. You must take adequate precautions and measures for airflow inside the rack as well as in the room so that the internal temperature can be kept within thi s ra n ge du ring operation.
z Required tool To install the device to the rack, a Phillips-head screw drive is required.
3-6 Installing Server
r
Checking the place to install
Decide the place (height) to install. To keep balance, install it as low as you can on the rack. To install the rack, the height for 4U is required.
Imprinted mark (2 imprinted marks fo 5Us)
Places to install core nuts
4U (the height for installing this device)
Imprinted mark
IMPORTANT:
To install this device to the rack, the space for 1U is required for installing the USB compatible floppy disk drive, in addition to the space for 4U.
Next to the square hole of the rack, an imprinted mark is placed for 1U (This is the unit to show the height of the rack). This device is as high as 4U (about 176 mm), so install it between the imprinted marks that indicate the height of 4U.
Installing this device
Follow the steps below to set the 4U chassis to the rack.
Front side of 4U chassis
Back side of 4U chassis
IMPORTANT:
4U chassis weighs about 10 Kg. To mount, remove or replace it, be sure to hold it with two or more people.
The following are the required accessories. Check if you have them all. Tool Name Qty
- Bracket 2
- Panhead screw 4
- Washer for panhead screw 4
- Plate screw (short) 8
- Plate screw (long) 4
- Washer for plate screw 12
Installing Server 3-7
(top
)
TIPS:
Core nuts (8 pieces) are not included. Use the core nuts that are attached to the rack.
1. If the rack has front and rear doors, read the instruction that comes with the rack, and open
them.
2. Install the brackets from the rear side of the rack. Install the brackets with its flat side facing
inside. Place them with the round screws with washers that come with the device
symmetrically (total: 4). Fasten the screws tentatively not tightly.
Panhead screws with
of device
washers
4U
3U
2U
1U
Bottom of
device
Plate
Panhead screws with
washers
Bracket (flat sides are facing inside)
3-8 Installing Server
3. Fix the core nuts to the front side of the rack.
Attach them symmetrically (total: 8 core nuts).
4U (top of device)
3U
2U
1U
Bottom of device
Fix a core nut from inside of the rack. Hook either of the clips of the core nut to a square hole of the rack, and hook the other clip to a hole by a flat-blade screwdriver.
Core nuts
Core nuts
Inside of the rack
Outside of the rack
4. Insert the 4U chassis from the front side
of the rack.
Installing Server 3-9
5. Tentatively fasten the washers and plate
screws (short) to the 4 places on the front
and back sides (total: 8) from the rear.
6. Fasten tightly the washers and round
screws (long) to the 2 places on the left
and right sides (total: 4) from the front.
Washers and plate screws (short)
Washers and plate screws (short)
Washers and plate screws (long)
3-10 Installing Server
7. Fasten tightly the 4 round screws on the back
side and the 8 plate screws on the side panels (which you fastened tentatively).
Panhead screws on the side
panels
8. Mount the CPU/IO module 0.
Mount the module while lowering the lock so the module stacks on the way.
Plate screws on the side panels
Plate screws on the side panels
Lock
9. Fasten the levers on the left and right sides
with screws.
Installing Server 3-11
10. Mount the CPU/IO module 1 in the same way.
3-12 Installing Server
Unmounting the device from the rack (N8140-74/92/93/94/98/99)
Follow the steps below and unmount the device from the rack.
Observe the following precautions to use the server safely. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling“ in Chapter 1.
Do not carry or install a rack alone. Do not squeeze your fingers in the product Do not impose a weight on the device when it is pulled out from the rack. Do not pull a device out of the rack if the rack is unstable. Do not leave more than one device pulled out from the rack. Do not pull the device from the rack while it is operating.
CAUTION
1. Check that the device is powered off, and remove all the power cords and interface cables that
are connected to the device.
2. Remove the front bezel.
3. Loosen the screws on the left and right sides of the front panel of the CPU/IO module and
release the lock by pulling the ejector toward you.
4. Pull out the CPU/IO module gently from the rack.
IMPORTANT:
- When you pull out the device, do not load anything on its top. It is dangerous, since the
device becomes unstable and it may fall.
- Do not hold the handle on the front side or the convex part on the back side. To move
the device, hold the bottom.
- Since the device is locked and can not be pulled out, pull it out after releasing the lock
by lowering the lock on the side of the CPU/IO module.
5. Hold tightly when you unmount 4U chassis from the rack,. To remove the mechanical parts of the rack, see the installation procedure.
Installing Server 3-13
p
p
INSTALLING the Tower Conversion Kit (N8843-002)
This section describes how to install the rack-mount model of NEC Express5800/ft series without using the dedicated rack.
IMPORTANT:
NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
Select a suitable site for tower model.
CAUTION
Observe the following precautions to use the equipment safely. There are risks of a burn, injury, or damage to physical assets. For details, see “Notes for Safe Handling“ in Chapter 1.
Remove all modules before moving the equipment. Do not install the equipment in non-designated places.
Close enough to connect the keyboard and the display.
Room that can maintain the following conditions during server operation: Temperature: 10 to 35ºC* Humidity: 20 to 80% (non-condensing)
AC parallel bi-polar power outlet with grounding
Floor or a level and robust desk or table
Wall outlet within the reach of supplied power cord.
Clean and tidy room
Location with an enough open space to fully open the front bezel, at least 1 m from the front, 50 cm .from the rear, and 15 cm from the sides of the server (The front bezel extrudes about 50 mm from the right side of the server when fully o
ened.)
Uninterruptible Power Supply (UPS) to prevent momentary voltage drop due to power failure or lightning * * Optional. UPS is recommended for best use of features of NEC
Ex
ress5800/ft series.
* It is recommendable to use the server in a
room where temperature can be kept between 15 and 25ºC.
3-14 Installing Server
Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction.
Place where temperatures change widely (near a heater, air conditioner, or refrigerator). Place that is subject to intense vibration. Place where corrosive gas (sodium chloride, sulfur dioxide, hydroge n sulfide, nitrogen dioxide,
or ozone) is generated, or a place that is close to chemicals or exposed to chemicals.
Place whose floor is covered with non-antistatic carpet. Place that may be subject to falling objects. Place where you may step or trip on the power cords or interface cables. Place that is close to some equipment that generates intense magnetic field (e.g., TV set, radio,
broadcasting/communications antenna, power transmission wire, and electromagnetic crane). (If unavoidable, contact your sales agent to request proper shield construction.)
Place where the power cord of the server must be connected to an AC outlet that shares the
outlet of another device with large power consumption.
Place that is close to some equipment that causes power noises (e.g., sparks caused by
power-on/off using a relay). If you must install the server close to such equipment, request your sales agent for separate power cabling or noise filter installation.
It takes at least three people to carry the server; hold it firmly by its bottom and place it slowly on the selected site.
IMPORTANT:
Do not hold the front bezel to lift it, or it may detach, fall down, and break the server.
After placing the main cabinet, lock its two front casters out of four and screw the attached four stabilizers on the cabinet adjusting their height.
Screws
Lock lever
Stabilizer
Installing Server 3-15
Steps to Install the Rack-mount Model to the Tower Conversion Kit
Follow the procedure below to install the devices to the tower conversion kit.
1. Open the front door of the tower conversion kit.
If the door is locked, use the server-accessory key to unlock.
2. Confirm the spots to fix 8 core nuts on the front
of the chassis. See the figure on the right for where to fix the core nuts (4 on the front top and 4 on the front bottom.)
8 core nuts have been installed on the front of the chassis.
Tower conversion kit (on the front top)
Tower conversion kit (on the front bottom)
3. Insert the bracket from the front of the conversion
kit. Tuck the bracket firmly to the back.
3-16 Installing Server
4. Fix the bracket with four washers and countersunk
screws (long ones), two at the top and two at the bottom.
5. Fix the bracket with 4 washers and countersunk screws. See the figure on the right for where
to fix the screws (2 screws for the backside on the top, and 2 for the bottom of the tower conversion kit).
Top (toward the backside) Bottom (toward the backside)
6. Insert the device slowly and securely into the bracket.
If it becomes rocked and cannot insert any further, push and keep the rock lever to the left as push the device further inside.
7. Close the lever on the top and the bo ttom
of the device. Fix the device to the bracket with clinchers.
8. Take steps 6 to 8 to fix the other device to the bracket.
Installing Server 3-17
Lock lever
3-18 Installing Server
Connect peripheral devices to NEC Express5800/ft series
The server provides connectors for a wide variety of peripheral devices on its front and rear. The figure on the next page illustrates available peripheral devices for the server in the standard configuration, and locations of the connectors for the devices. After connecting the peripheral devices, connect the provided power cords with the server, and then plug the power cords into the power outlet.
Observe the following precautions to use the server safely. There is a risk of a death or serious injury. For details, see “Notes for Safe Handling“ in Chapter 1.
Do not hold the power plug with a wet hand. Do not connect the ground wire to a gas pipe.
WARNING
Observe the following precautions instructions for the safe use of the equipment. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling“ in Chapter 1.
Do not plug the power cord in a nonconforming outlet. Do not plug too many cords in a single outlet. Do not plug the cord insecurely. Do not use nonconforming power cords.
CAUTION
IMPORTANT:
Power off the server before connecting peripheral devices, with the exception of
peripherals with USB interface. Connecting a powered peripheral device to the powered server will cause malfunctions and failures.
To connect a third-party peripheral device or interface cable to the server, check with
your sales agent to see if they are compatible with NEC Express5800/ft series. Some third-party devices may not be used with the server.
The total cable length of SCSI device connections is up to 6 m, including the internal
SCSI cables.
The serial port connectors are reserved for maintenance. Place the USB floppy disk drive on the server. Space of 1U is needed to put it on the
server.
IMPORTANT:
)
A
Connection of optional devices
In the case of standard configuration, you need to complete setup of the operating
system before mounting optional PCI cards o r har d di sks that you purchased separately.
If N8803-035 is mounted, be sure to connect cables to the FC array unit before going
on to the next step.
LAN port (VTM) (Connect only when using the ft Remote Management Card
USB connection modem
USB floppy disk drive
Installing Server 3-19
Keyboard (via keyboard hub to USB mouse)
Display
Back of the device
FTER every peripheral device is connected, insert the power cord into a socket. the outlet.
Hub
(multiport repeater)
To a 1000Mbps network
Serial Interface
Connect the device with the serial interface (This cannot be used since it is for maintenance.)
3-20 Installing Server
Rotate the stopper clockwise, and insert the power cords to the AC inlets of the power unit.
Connect the plug at the other end of the power cord to a wall outlet with parallel double-pole grounds provided or to an uninterruptible power supply (UPS).
To use the functions of the server, you should connect the server to the UPS.
Stopper
IMPORTANT:
Be sure to use both of the power cords to make the server fault-tolerant. After connecting the power cords, wait at least 30 seconds before pressing the power
switch.
By pressing the power switch, the power switch’s fans starts to rotate.
To connect the power cords from the server to an
<Example>
uninterruptible power supply (UPS), use service outlets on the rear of the UPS.
The UPS service outlets are categorized into two groups: SWITCH OUT and UN-SWITCH OUT. (They may be called “OUTPUT1“ and “OUTPUT2“.)
To restrict the power supply from ESMPRO/AutomaticRunningController, connect the power cable to SWITCH OUT.
For constant power supply, connect the power cords to a UN-SWITCH OUT outlet. (Connect the modem that is in service for 24 hours to this outlet.)
When the power cords from the server are connected to a UPS, change the BIOS setup of the server to link with power supply from the UPS.
Select [AC-LINK] from [Server] on the BIOS setup utility and change parameters. See the separate volume of User’s Guide for details.
Windows Setup 4-1
Chapter 4
Windows Setup
This chapter describes procedures such as configuring OS Boot Monitoring function, setting dual LAN configuration, and setting dual disk configuration.
4-2 Windows Setup
Before starting Setup
Read this section before starting setup. This chapter describes two types of setup.
Procedures to Install and Reinstall the Windows OS
Installing and Reinstalling Windows Server 2003 x64 Edition
“Manual Install” is required to install/reinstall OS (Windows), the disk drivers and other utilities manually and individually.
Installing Windows Server 2003
Use NEC EXPRESSBUILDER to install/reinstall Windows Server 2003.
“Express Setup” is the setup program that is specific to NEC Express5800/ft series. NEC EXPRESSBUILDER DVD, a server accessory, runs this setup program. Express Setup enables automatic install of Windows Server 2003 and other various utilities.
Refer to “Procedure to Install and Reinstall OS.” Use this setup step if you want to reinstall OS or use the HDD with a partition setting that is different from the default partition setting.
Windows Setup 4-3
N
t
p
SETUP FLOW
0
This flow chart illustrates the flow of the setup
rocedures for the NEC Express5800/320Fd-MR.
Windows Server 2003 x64 Editions (Manual Setup)
Step 4B Manual Setup
Create [OEM-Disk]
Set OS (Windows) CD-ROM
Install driver in [OEM-Disk]
Start the OS installation
Apply [Update the system]
Install ft Server Control Software
EC ESMPRO/ServerAgen
and
Step 5 Install Windows Server 2003 Service Pack
Step 6 Set Dual LAN Configuration
Step 7 Set Dual Disk Configuration
Step 8 Update Software
Step 9 Connect and Configure Options
Step 1 Start the OS reinstallation setup procedure
Step 2 Prepare the OS reinstallation setup
Step 3 Disable OS Boot Monitoring Function
Windows Server 2003 (Express Setup)
Step 4A Express Setup
Set [NEC EXPRESSBUILDER] DVD
Specify the size of the partition for OS installation
Prepare for Windows Server 2003 R2 32-bit Enterprise Editions installation and ft Server Control Software installation
Set Windows Server 2003 R2 32-bit Enterprise Edition CD-ROM
Automatic installation of following software:
Windows Server 2003 R2 32-bit Enterprise Edition ft Server Control Software, ESMPRO Server/Agent
Step 10 Create Volume
Step 11 Set Network for NEC ESMPRO
Step 12 Enable OS Boot Monitoring
Step 13 Make Settings for Failure
Step 14 Back up System Information
: Entered or selected by the user
: Proceeds automatically
Completion
4-4 Windows Setup
Step 1: Procedure to Install and Reinstall OS
The following explains OS install and reinstall:
IMPORTANT:
“Express Setup” deletes all data on the disk used for installation/reinstallation, as
“Express Setup” formats the entire disk. If there is any data partition other than the system partition containing OS for reinstallation, you must back up the important data in the data partition first and then start “Express Setup.”
Do not apply service packs to NEC Express5800/ft series based on your judgment.
If you want to apply service packs, contact your sales agent for the latest application and apply service packs to NEC Express5800/ft series.
Following items are required for install/reinstall:
For Windows Server 2003 x64 Editions
NEC EXPRESSBUILDER DVD ft Server Control Software UPDATE CD-ROM
This CD-ROM is used to update ft Server Control Software; it may not be shipped with the equipment. (Not included if “NEC EXPRESSBUILDER”DVD contains the latest version of software programs at the time of shipment.)
Microsoft® Windows Server™ 2003 R2, Enterprise x64 Editions Disk 1
(hereinafter referred to as “Windows Server 2003 x64 Editions CD-ROM”) Microsoft® Windows Server™ 2003 R2, Enterprise x64 Edition Disk 2 (One set consists of 2 disks.)
Windows Server 2003 x64 Editions Service Pack CD-ROM
Apply Windows Server 2003 x64 Editions Service Pack 2.
Windows Server 2003 x64 Edition OEM-Disk for EXPRESSBUILDER (or one 1.44MB,
DOS-formatted 3.5-inch floppy disk.)
User’s Guide (Setup) (this manual) User’s Guide
For Windows Server 2003
NEC EXPRESSBUILDER (DVD) ft Server Control Software UPDATE CD-ROM
This CD-ROM is used to update ft Server Control Software; it may not be shipped with the equipment. (Not included if “NEC EXPRESSBUILDER”DVD contains the latest version of software programs at the time of shipment.)
Microsoft® Windows Server™ 2003 R2 32-bit Enterprise Edition Disk 1
(hereinafter referred to as “Windows Server 2003 CD-ROM”)
Windows Setup 4-5
Microsoft® Windows Server™ 2003 R2 32-bit Enterprise Edition Disk2 (One set consists of two disks.)
Windows Server 2003 Service Pack CD-ROM
It is recommended to apply the latest service pack supported by ft Server.
User’s Guide (Setup) (this manual) User’s Guide
IMPORTANT:
About the latest release of ft Server Control Software and purchase of the latest
version of its Update CD-ROM, ask your sales agent.
Before starting the setup, decide the size of the partition for the operating system.
4-6 Windows Setup
Size of the Partition to be Created
For Windows Server 2003 x64 Editions:
The required minimum size of a partition to install the system can be obtained from the following formula:
Size required for installation + paging file size + dump file size
Size required for installation = 5,900MB (Windows Server 2003 R2) Paging file size (recommended) = size of memory mounted* × 1.5 Dump file size = size of memory mounted* + 1MB
IMPORTANT:
The above paging file size is necessary for collecting debug information (memory
dump). The boot volume requires a paging file size that is large enough to store the dump file. Set an adequate paging file size for the entire system, since an inadequate amount of paging file might cause a harvest of incorrect debug information (memory dump).
The maximum size of the dump file is “mounted memory size + 1MB,” regardless of
the mounted memory and the debug information (the types of memory dump).
If you need to install other applications, add the capacity of hard disk required for those
applications.
For example, if memory of 1GB is mounted, the required minimum partition size obtained from the above formula is as follows:
5,900MB + (1,024MB × 1.5) + 512MB + 1MB = 7,949MB
For Windows Server 2003:
You can obtain the required minimum size of the partition to install the system from the following formula:
Size required for installation + paging file size + dump file size
Size required for installation = 5,300MB (Windows Server 2003 R2) Paging file size (recommended) = size of memory mounted* × 1.5 Dump file size = size of memory mounted* + 12MB
IMPORTANT:
The above paging file size is necessary for collecting the debug information (memory
dump). If a value smaller than the “Recommended” one is set for the initial size of the paging file, correct debug information (memory dump) may not be collected.
The maximum paging file size is 4095MB in a partition. If 1.5 times the size of
mounted memory is larger than 4095MB, set the size at 4095MB.
If the size of mounted memory is larger than 2GB, the maximum size of dump file is
“2048MB+12MB.”
Windows Setup 4-7
TIPS: The mounted memory size means the total of memory installed on a single CPU/IO
module.
For example, if memory of 1GB is mounted, the required minimum partition size obtained from the above formula is as follows:
5,300MB + (1024MB × 1.5) + (1024MB +12MB) = 7,842MB
4-8 Windows Setup
Step 2: Prepare for Express Setup
Before starting Express Setup, be sure to do the following. You can set up properly only when you make those preparations.
2-1: Prepare NEC Express5800/ft series
With the power of NEC Express5800/ft series off, follow the steps below:
1. Prepare NEC Express5800/ft series.
Mount the modules for both systems.
Mount only one hard disk to the Slot 1 of the CPU/IO module 0.
Remove all LAN cables.
Remove optional SCSI devices such as a tape device from the SCSI connector.
Remove cables from the connectors attached to the Fibre Channel board.
IMPORTANT:
Mount only one HDD to the designated slot of the designated CPU/IO module. If multiple HDDs are mounted, the hard disk to install OS cannot be determined.
2. Prepare the installation from the CPU/IO module 0. Mount a HDD to the designated place
when installing the OS.
The location of the parts required for operation and checking are shown below:
CPU/IO module 0 Power LED
CPU/IO module 0
CPU/IO module 0 POWER switch
Be sure to keep this turned on.
CPU/IO module 0 Status LED
CPU/IO module 1 Power LED
CPU/IO module 1 Status LED
CPU/IO module 1
CPU/IO module 1 Power switch
Front side of device
Mount only one HDD here when you install/reinst all OS .
CPU/IO module 0 DISK ACCSSS LED
CPU/IO module 1 DISK ACCESS LED
Windows Setup 4-9
AC Inlet Connector A
CPU/IO module 0 Status LED
PCI Slot Status LED
DUMP (NMI) Switch
CPU/IO module 1 Status LED
Rear side of device
AC Inlet
Connector B PCI Slot Status LED
When the AC power is on (The power cords are plugged into the wall outlet )
(1) Confirm the POWER LED of the CPU/IO module.
z If the POWER LED is illuminated, shut down the OS and unplug the AC
power cord after the POWER LED turns off.
z If the POWER LED is turned off, unplug the AC power cord.
(2) Execute the operation to be taken when AC power supply is turned off.
When the AC power is off (The power cord is not plugged into the outlet)
Connect the power cords to NEC Express5800/ft series in the following order:
(1) Connect the power cord to the AC inlet A connector. (2) Connect the power cord to the AC inlet B connector. (3) Make sure that the CPU/IO module status LED is turned off.
Preparation is now completed.
4-10 Windows Setup
Step 3: Disable OS Boot Monitoring Function
Check whether the power is ON and make settings for properly performing setup for later on. This server has a function to monitor the main unit at startup. (Enabled in the configuration at shipment) When installing/reinstalling the operating system, this monitoring function needs to be disabled; otherwise the OS may not install properly. Follow the steps in this section and make proper settings.
IMPORTANT:
If you skip the settings described here, the system will be forcefully restarted while Windows setup screen is shown and the setup will be unsuccessful. BIOS may repeat Windows setup in an invalid manner. In this case, you will need to restart the setup procedures from the beginning.
TIPS:
For details of operations for BIOS Setup Utility and parameters, see the separate volume of User’s Guide.
Procedure for Changing BIOS settings
1. Turn on the display and the peripheral equipment connected to the NEC Express5800/ft
series.
CHECK:
If the power cords are connected to a power controller like a UPS, make sure that it is powered on.
2. Detach the front bezel.
Windows Setup 4-11
3. Press the POWER switch located on the front side of the server. (You can see LEDs lit on
this side.)
module 0 Power LED
CPU/IO module 0 Status LED
CPU/IO module 1 Power LED
CPU/IO module 0CPU/IO
CPU/IO module 1 Power LED
CPU/IO module 1 Status LED
Front side of device
CPU/IO module 1
CPU/IO module 1 Power switch
IMPORTANT:
Do not turn off the power before the “NEC” logo appears.
After a while, the “NEC” logo will appear on the screen.
While the “NEC” logo is displayed on the screen, NEC Express5800/ft series performs a power-on self test (POST) to check itself. For details, see the separate volume of User’s Guide.
CHECK:
If the server finds errors during POST, it will interrupt POST and display the error message. See the separate volume of User’s Guide.
4-12 Windows Setup
4. When the message “Press <F2> to enter SETUP” or “Press <F2> to enter SETUP or Press <F12> to boot from Network” is displayed on the display screen, press F2.
The BIOS Setup Utility “SETUP” starts and the Main menu is displayed on the screen.
Example:
ftServer Setup
Main Advanced Security Server Boot Exit
System Time: [16:54:28]
System Date: [05/07/2007]
CPU Speed 2.70 GHz Physical CPUs 1
System Memory 640 KB Extended Memory 2047 MB Cache Ram 4096 KB
SATA AHCI Enable [Disabled]
Item Specific Help
<Tab>, <Shift-Tab>, or <Enter> selects field.
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults Esc Exit ←→ Select Menu Enter Select Sub Menu F10 Save and Exit
Windows Setup 4-13
p
5. Move the cursor onto “Server” and select “Server.”
The Server menu will be displayed:
ftServer Setup
Main Advanced Security Server Boot Exit
System Management
Console Redirection Event Log Configuration Monitoring Configuration
Post Error Pause: [Enabled]
AC-LINK: [Last State] Power On Delay Time: [ 0]
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults Esc Exit ←→ Select Menu Enter Select Sub Menu F10 Save and Exit
Item Specific Help
Additional setup menu to view server management features.
6. Move the cursor onto “Monitoring Configuration” and press Enter.
The Monitoring Configuration submenu appears:
Main Advanced Security Server Boot Exit
ftServer Setu
Monitoring Configuration Item Specific Help
FRB-2 Timer [Enabled]
PCI Enumeration Monitoring: [Enabled] PCI Enumeration Monitoring Timeout: [ 180]
Option ROM Scan Monitoring: [Enabled] Option ROM Scan Monitoring Timeout: [ 300]
OS Boot Monitoring: [Enabled] OS Boot Monitoring Timeout: [ 600]
POST Pause Monitoring: [Enabled] POST Pause Monitoring Time-out [ 180]
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults Esc Exit ←→ Select Menu Enter Select Sub Menu F10 Save and Exit
Disables/enables the FRB-2 Timer.
4-14 Windows Setup
7. Move the cursor onto “OS Boot Monitoring” and press Enter.
Parameters will be displayed.
8. Among the parameters, choose “Disabled” and press Enter.
The current display of the configuration for OS Boot Monitoring will be changed to “Disabled.”
ftServer Setup
Main Advanced Security Server Boot Exit
Monitoring Configuration Item Specific Help
FRB-2 Timer [Enabled]
PCI Enumeration Monitoring: [Enabled] PCI Enumeration Monitoring Timeout: [ 180]
Option ROM Scan Monitoring: [Enabled] Option ROM Scan Monitoring Timeout: [ 300]
OS Boot Monitoring: [Disabled]
OS Boot Monitoring Timeout: [ 600]
POST Pause Monitoring: [Enabled] POST Pause Monitoring Time-out [ 180]
Disables/enables the FRB-2 Timer.
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults Esc Exit ←→ Select Menu Enter Select Sub Menu F10 Save and Exit
Windows Setup 4-15
9. Press the Esc key to go back to the Server menu, and then move the cursor and select
“Exit” to display the Exit menu.
ftServer Setup
Main Advanced Security Server Boot Exit
Exit Saving Changes
Exit Discarding Changes Load Setup Defaults Discard Changes Save Changes
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults Esc Exit ←→ Select Menu Enter Select Sub Menu F10 Save and Exit
10. Move the cursor onto “Exit Saving Changes” and press Enter.
The confirmation window will appear.
Setup Confirmation
Save configuration changes and exit now? [Yes] [No]
11. Select “Yes” and press Enter.
Item Specific Help
Exit System Setup and save your changes to CMOS.
The configuration data is saved, SETUP terminated, and the system rebooted. This is the end of steps for switching OS Boot Monitoring function.
TIPS:
After the procedure above is completed, power off this server to prepare for installation. Then, referring to “Step 4A : Start Express Setup” on the next page to continue the setup.
4-16 Windows Setup
Step 4A : Start Express Setup
Set up with the Express Setup functions of NEC EXPRESSBUILDER.
“Express Setup” is a setup method for NEC Express5800 series that allows configuration of hardware internal parameters and status and installation of OS (Windows Server 2003) and various utilities in seamless manners by using “NEC EXPRESSBUILDER” DVD which comes with the server. Use the “Express Setup” to install the OS. It performs complicated setups automatically.
Express Setup edits the information required for the setup, saves it to a floppy disk before the setup, reads the information one by one at the setup and automatically performs a series of setup processes.
TIPS:
Parameters file is a setup file that stores the information set/selected during Express
Setup. Express Setup executes all the setup process automatically, based on this information. It is not necessary to sit by the system and check the status during the setup. If you use the parameters file that has been used last time, you can create the same setup condition as the previous one.
You can create a parameter file in advance, by using “Parameter File” in NEC
EXPRESSBUILDER.
If you create a parameters file in advance, you can skip the options that need to be
entered or selected during Express Setup. (You can create or modify the setup information in the parameters file, during Express Setup.) If any computer that is running on Windows XP/Vista/Windows Server 2003 is available, it is recommended to edit the setup information with parameters file Creator in advance.
This device does not include the floppy disk (FD) drive by standard. Prepare an
optional floppy drive when you create and use parameters file.
Windows Setup 4-17
t
Next
N
N
N
N
Flow of Setup Procedures
The following flow chart illustrates the setup procedures for Express Setup.
Remove the Floppy Disk and CD/DVD-ROM from the drive
Insert Windows CD-ROM
Loading parameters (Step 2)
ext
Select the operating system (Step 3)
RAID configuration (Step 4)
ext
Windows Confirm Setting / Input (Step 5 to 10)
ext
Save parameters (Step 11)
ext
Start Express Setup (Step 12)
Perform
Create the OS partition / format
Copying Windows driver
Copying Selected Application
Skip
Agree Software License Agreemen
Install OS Automatically
Log on Automatically
The installation is completed
: Process that needs to input or select : Process that proceeds
automatically
4-18 Windows Setup
Setup Procedures
Express Setup precedes the setup by selecting or inputting several parameters on the wizard. You can also save the parameters to a floppy disk as a parameters file.
CHECK:
To execute Express Setup with a parameter file, one empty 1.44MB formatted floppy disk is required. Prepare an empty floppy disk in advance.
When you reinstall OS, you can skip entering the parameter in the Wizard form, by reading the parameter file that has been saved.
IMPORTANT:
In case of changing the system configuration, update the system (page 6-8).
1. Turn the power of peripheral device on, and then turn on the server.
2. Insert the NEC EXPRESSBUILDER DVD into the optical disk drive of the server.
3. Press the RESET switch or press Ctrl, Alt, and Delete to reboot from the NEC
EXPRESSBUILDER. (You may also turn off and then on again to reboot the server.)
The system will boot from the DVD-ROM and NEC EXPRESSBUILDER starts. Select “OS installation *** default ***” from the boot selection menu. (If you do not hit any key, “OS installation” is selected automatically.)
The Top menu will appear.
4. Select [Perform the Express
setup] from the Top Menu, click [Next].
Windows Setup 4-19
5. [Load parameters] steps are displayed.
[Load parameters] (1) Select [Do not load parameters]. (2) Click [Next].
NOTE: If a floppy disk drive is
not connected, select this item.
[When you load parameters] (1) Insert the floppy disk
containing the parameters file.
(2) Select [Load parameters];
enter the file path of the parameters file into the text box.
(3) Click [Next].
6. Select the installing Operating
System.
Select [Install Windows (32-bit editions)] from the menu, click [Next].
4-20 Windows Setup
7. Enter the setting of a logical
drive.
[Enter RAID settings] steps are displayed. Retain the default value, and click [Next].
8. Specify the installing medium
and the Windows system partition.
[Specify medium / Partition] steps are displayed. Confirm the parameters, modify if necessary, and click [Next].
IMPORTANT:
About partition size
1. Specify the partition size larger than required minimum size for OS installation.
2. Do not specify larger partition size than the capacity of connected hard disk drive.
If you select “Create a new partition” at “Windows system drive settings,” the
contents of the hard disk will be all deleted.
If “Use existing partitions” is selected, EXPRESSBUJILDER installs the
Operating System to the first partition (first partition is deleted). The data in the other partition is kept if the system has two or more partitions (see the figure below).
Windows Setup 4-21
You cannot reinstall the system with the existing partition that is upgraded to
Dynamic Disk remained. Do not select “Use existing partitions” at “Windows system drive settings.”
9. Enter the user information
and client license mode.
[Enter basic parameters] steps are displayed. Confirm the parameters, modify if necessary, and then click [Next].
NOTE: Even if you do not input value into “Administrator password,”
“Confirm password,” “??????” is displayed.
4-22 Windows Setup
10. Enter the setting of
the network protocol.
[Enter Network Protocol] steps are displayed. Retain the default value, and click [Next].
11. Enter the domain or
workgroup name to be used.
[Enter domain account] steps are displayed. Retain the default value, and click [Next].
12. Select the installing
components.
[Select Windows components] steps are displayed. Retain the default value, and click [Next].
13. Select the installing
applications.
[Select applications] steps are displayed. Retain the default value, and click [Next].
14. Save the parameters.
[Save parameters] steps are displayed.
If you want to save the parameters, set free formatted floppy disk.
Select [Save parameters], enter the file path of the parameters files into the textbox and click [Next].
If not, select [Do not save Parameters].
Windows Setup 4-23
4-24 Windows Setup
15. The Express Setup will start
when you click [Perform] in [Start Express setup] step.
16. Remove NEC EXPRESSBUILDER DVD from the optical disk drive according to the
message.
If you proceed the setup y using setup parameter file, remove the floppy disk from the floppy disk drive.
Insert Windows Server 2003 CD-ROM into the optical disk drive.
[Agree Software License Agreement] screen appears.
17. Read the contents carefully and click [Yes] if you do agree. If do not agree, click [No].
NOTES:
If you do not agree to this agreement, the setup terminates and Windows Server
2003 will not be installed.
If “NetWare Gateway (and Client) Service” is specified to install, the window to
specify the details of “NetWare Gateway (and Client) Service” pops up on the first logon. Specify the appropriate value.
Windows Server 2003 and selected applications will be installed automatically and rebooted several times. After rebooting, it logs on to the system automatically.
18. Insert Microsoft Windows Server 2003 R2 Standard Edition DISK 2 into the optical disk
drive after the OS installation.
Hereafter, proceed operations according to the message.
When the installation has finished, remove Microsoft Windows Server 2003 R2 Standard Edition DISC 2 from the optical disk drive, and restart the system.
Now the Setup using Express Setup has completed.
Windows Setup 4-25
Step 4B: Manual Setup
Follow the procedures below to create “OEM-Disk” before starting the OS install.
Preparing to Install
Windows Server 2003 x64 Editions
You can create a Windows Server2003 x64 Edition OEM-Disk for EXPRESSBUILDER by following two procedures.
Create from EXPRESSBUI LDER
Select this procedure when the NEC Express5800 series is the only computer for creating Windows Server2003 x64 Edition OEM-Disk for EXPRESSBUILDER. If Windows Server 2003 x64 Editions operates on the NEC Express5800, you can also select [Create from the menu start by auto-run] described later.
The procedure is as follows:
1. Prepare one 3.5-inch floppy disk.
2. Insert the “NEC EXPRESSBUILDER”DVD into the optical disc drive.
3. Reset (Press <Ctrl> + <Alt> +<Del>) or power off to reboot the Express5800 series.
System launches from the DVD-ROM, and NEC EXPRESSBUILDER starts.
4. Select [Create the OEM-Disk for Windows] from the [Step 1, Top menu], then click [Next].
5. Select [Create Windows Server 2003 x64 Edition OEM-Disk for EXPRESSBUILDER] from
the [Create Windows OEM-Disk], then click [Perform].
6. Follow the instruction on the screen and set the floppy disk into the floppy disk drive.
[Windows Server 2003 x64 Editions OEM-Disk for EXPRESSBUILDER] is created.
Protect the disk from overwrite and label as [Windows Server 2003 x64 Edition OEM-Disk for EXPRESSBUILDER]. Store this OEM disk in a safe place.
Create from the menu start by auto run
Menu starts automatically by the auto run function when you load the DVD into an optical disc drive that is mounted on a computer running an operating system Windows 2000 + Internet Explorer
6.0, Windows XP, Windows Vista or Windows Server 2003. From this menu, you can create [Windows Server2003 x64 Edition OEM-Disk for EXPRESSBUILDER]. (Including Express the NEC 5800 series)
4-26 Windows Setup
The procedure is as follows:
1. Prepare one 3.5-inch floppy disk.
2. Start the operating system.
3. Insert the NEC EXPRESSBUILDER DVD into the optical disk drive. The menu launches.
4. Click [Create drive disk (for Windows)], and select [OEM-Disk for Widows Server 2003 x64
Edition].
NOTE:
This operation is also possible on the menu that appears by right click.
5. Follow the instruction on the screen and set the floppy disk into the floppy disk drive.
[Windows Server 2003 x64 Edition OEM-Disk for EXPRESSBUILDER]. Store this OEM disk in a safe place.
Windows Setup 4-27
Installing Windows
Windows Server 2003 x64 Editions Installation
Follow the procedure below to install.
1. Power on the system.
2. Load the backup CD-ROM DISK 1 or the Windows Server 2003 x64 Edition DISK 1 into
the optical disk drive.
3. After loading the backup CD-ROM DISC 1 or the Windows Server 2003 R2 x64 Edition
DISC 1 into the optical disc drive, reset (Press <Ctrl> + <Alt> +<Del>), or power off to reboot the NEC Express5800 series.
System launches from the CD-ROM, and NEC EXPRESSBUILDER starts.
IMPORTANT:
When a bootable OS is already installed on the HDD, press <Enter> key while [Press any key to boot from CD…] is appearing on the top of the screen. You do not need to operate this if no bootable OS is installed. If the Windows Setup screen does not appear after this operation, it means <Enter> key was not pressed properly. Power on to restart the system and start from the beginning.
4. Press <F6> key while either of the following messages appears on the screen.
On the top of the screen: [Setup is inspecting your computer’s configuration…] On the bottom of the screen: [Press F6 if you need to install a third party SCSI or RAID driver]
TIPS: After pressing <F6> key, no change appears on the screen.
4-28 Windows Setup
5. Press <S> key when the right message
appears.
The right message appears.
6. Set Windows Server 2003 x64 Edition OEM-Disk for EXPRESSBUILDER floppy disk into
the floppy disk drive, then press <Enter>. SCSI adapter list appears.
7. Select [Stratus Virtual Disk Driver], then press <Enter>.
Go back to the step 5 screen and press <Enter>.
8. Select [Stratus Embedded SAS Adapter], then press <Enter>
9. Press <Enter> and start Windows setup
when the right message appears.
IMPORTANT:
– On the process of the setup, the request to configure the partition size of
Windows Server 2003 x64 Editions installation appears on the screen.
– When you try to install Windows Server 2003 x64 Editions on a disk that has larger
partition than 2,097,152MB (2TB), the partition size should be 2,097,152MB and less.
Windows Setup 4-29
y
– When there are multiple logical drives, select a partition that you would like to
install the OS after the next message appears.
The following list shows the existing partitions and unpartitioned space on this computer. Use the UP and DOWN ARROW ke
– You cannot change drive letters for the system volume or the boot volume after
completing the setup. Make sure the drive letter is allocated to proper drive on this screen, and then proceed the setup. After completing the setup, the drive letters may not be the same as before the setup. If you would like to change the drive letters, follow the procedure [How to change drive letters] described later.
TIPS:
After copying the files, the system automatically reboots. You do not have to eject the floppy disk and the CD-ROM. When you do not eject the floppy disk, do not eject the CD-ROM either. Follow the instructions on the screen to continue the setup. Refer to [Fist Step Guide] for details.
s to select an item in the list.
10. After installing Windows Server 2003 x64 Editions, the system automatically reboots.
11. After logging on the system, [Windows Setup] screen appears.
IMPORTANT:
– [Windows Setup] screen may not appear; however, make sure to install
Microsoft Windows Server 2003 R2 x64 Editions DISK 2.
– After applying [Update the system], you can install Microsoft Windows Server
2003 x64 Edition DISK 2. Make sure to install Microsoft Windows Server 2003 R2 x64 Edition. [Windows Setup] screen does not appear this time.
12. Load the Microsoft Windows Server 2003 R2 x64 Edition DISK 2 into the Optical disk drive.
Check the setting, then click [OK].
13. After the installation, eject the Microsoft Windows Server 2003 R2 x64 Edition DISK 2 from
the Optical disk drive, then reboot the system.
14. Follow the steps below to update the system.
Do not input or output data during the update process.
a) After logging on to the system as a user with the Administrative account, insert NEC
EXPRESSBUILDER DVD into the drive of the server.
b) When the “Autorun Munu” screen appears, click [Setup Windows] and click [Update the
sysmte] on the menu.
4-30 Windows Setup
1) When the dialog box for confirmation of executing system update appears, click [OK]. The system update will start. Follow the instructions.
2) After the system update is completed, the dialog box below will be displayed. Click [OK]. The system will be rebooted. Eject a DVD from CD/DVD-ROM drive after the reboot process starts.
IMPORTANT:
When “Found New Hardware” wizard appears at the reboot, click [Cancel]. If the same message appears again, click [Cancel] again.
3) Reboot the system.
15. Install ft Server Control Software
IMPORTANT:
Terminate all programs before starting the installation. You must terminate all programs because the software will not be installed successfully, especially when Microsoft management console is running.
1. Follow the steps below to install ft Server Control Software.
a) After logging on to the system as a user with the Administrative account, insert the
“NEC EXPRESSBUILDER” DVD-ROM into the DVD-ROM drive of the server.
b) The menu screen starts up. Click [Setup software] and select [ft Server Control
Software] on the menu.
Follow the instructions to with the installation. The message “ft Server Control
Software, Now Installing... Please Wait.” is displayed while ft Server Control Software. Do not use the keyboard or mouse while this message is being displayed.
2. The system is rebooted during the installation.
The system is rebooted several times during the installation. Remove the DVD from the DVD-ROM drive once rebooting is started. After the system is rebooted, log in again as the user logged in before rebooting. Installation of the ft Server Control Software is continued.
3. The message “Installation finished.” is displayed.
Once the installation is completed, the message “Installation finished.” is displayed and
Windows Setup 4-31
the rebooting starts by clicking [OK]. Change this screen to check the message, as the message can hide behind the screen.
For using “ft Server Control Software UPDATE CD-ROM” to update ft Server Control Software: After installing the ft Server Control Software, follow the procedure on the setup card attached to the “ft Server Control Software UPDATE CD-ROM” and apply the update.
16. For how to install NEC ESMPRO/ServerAgent,
see “NEC ESMPRO Agent”(Page 5-3).
IMPORTANT:
Make sure that “System Update” is applied and that “ft Server Control Software” and “NEC ESMPRO Agent” are installed.
Follow Step5.
Changing Drive Letters
You can change the drive letters with the following procedure:
NOTE:
The following procedure does not change the drive letters for the system volume or the boot volume.
1. Go to the start menu, right click [My Computer], select [Manage] and then launch
[Computer Management].
2. Select [Disk Management] in the left window.
3. Select and right-click a volume that you want to change the drive letter,
then select [Change Drive Letter and Path for…].
4. Click [Change].
5. Click [Change Drive Letter or Path], then select a letter for the drive.
6. Click [OK].
7. Click [Yes] after confirming the following message.
8. Exit [Computer Management].
Changing the drive letter of a volume might cause programs to no longer run. Are you sure you want to change this drive letter?
4-32 Windows Setup
Windows Setup 4-33
Step 5: Windows Server 2003 Service Pack Installation
Installing Windows Server 2003 Service Pack
A Service Pack for Windows Server 2003 x64 Edition and Windows Server 2003 is not applied to the system immediately after Windows install and re-install.
Refer to “Applying Windows Service Pack” on page 5-14, and apply Windows Server 2003 x64 Edition and Windows Server 2003 Service Pack.
IMPORTANT:
The Service Pack 2 for Windows Server 2003 x64 Edition or for Windows Server 2003 must be installed on the NEC Express5800/ft server.
There is no Hot Fix when this User’s Guide is issued. Contact your sales representative for the latest Service pack or the Hot Fix.
Step 6: Set Duplex LAN Configuration
The NEC Express5800/ft series builds a duplex LAN configuration by using “Stratus emb-EB 2-Port Gigabit Adapter” mounted as standard on the CPU/IO module and extended PCI slot “NEC MT Gigabit Adapter,” “NEC MF Gigabit Adapter,” and “Stratus U575 Dual Port Copper Gigabit Adapter.”
Overview
The duplex LAN configuration is of three types as described below:
Adapter Fault Tolerance (AFT)
Adapter Fault Tolerance (AFT) is a feature that places more than one LAN controller on the same LAN (same segment), and automatically switches the process of the primary controller to the backup controller when any trouble occurred on the primary.
Adaptive Load Balancing (ALB)
Adaptive Load Balancing (ALB) is a feature that connects more than one LAN controller to the same hub and enhances the throughput by operating packet transmission from the server.
Receive Load Balancing (RLB) is enabled by default. Disable RLB. When RLB is enabled, the network duplex configuration may fail.
Switch Fault Tolerance (SFT)
Switch Fault Tolerance is a feature that provides the network availability as the failover target (standby) adapter takes over MAC address and L3 address by connecting each two adapters to each two switches when a problem occurs on the adapter, cable or connecting target. One is assigned to the primary adapter and the other is to the standby. The primary adapter
4-34 Windows Setup
communicates on the network.
Regarding the path redundancy, you need to construct the environment by using the spanning tree not only on the server side but also on the switch side. You need to set the priority of the switch so that the path through the primary adapter is available even when a switch on the path is broken and the path information is updated.
The other modes, “Static Link Aggregation” and “IEEE 802.3ad Link Aggregation” do not contribute to an enhancement of the fault tolerance. When a fault occurs, the communication performed on the controller with the fault will be lost; the backup controller does not take it over.
Windows Setup 4-35
NEC Express5800/ft Series Duplication Rule
Be sure to set the duplex configuration in the server.
Also, when you set the duplex configuration, be sure to use one CPU/IO module 0 adapter and one CPU/IO module 1 adapter.
e.g.1) Set the duplex configuration with the improved endurance using all the adapters.
CPU/IO module 0 CPU/IO module 1
Network
e.g.2) Set the duplex configuration for more than one LAN connection
CPU/IO module 0 CPU/IO module 1
Network 1 Network 2
Duplex Configuration Setup
The following describes the procedure to set duplex LAN configuration.
The procedure to set the duplex LAN configuration of the example 1 in “NEC Express5800/ft Series Duplication Rule” above is explained.
To set the duplex LAN configuration, log on as “Administrator” or a member of the group “Administrators.”
1. Start Device Manager.
4-36 Windows Setup
2. Select one target network adapter, right-click on it and select [Properties] from the
displayed menu to display the Properties window.
3. Select the [Teaming] tab in the Properties window. Check the radio button of [Team with
other adapters] and click [New Team…].