Nec 60004033 Quick Start Guide

Page 1
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Contents:
Product Description and Notes Page 1 Tilt Angle and Rotation Page 1 Ventilation Recommendations Page 2 Display Dimensions Page 3-4 Display Dimensions with stand Page 5 Optional Table Top Stand Dimensions Page 6 Dimensions of Optional Wall Mount (WMK-3255S) Page 7 Compute Module Integration Page 8 Control Codes Page 9 Input Terminals Page 10 Browser Control Page 10
Product Description
V404 P404
Power Consumption (Max Brightness) 95W 115W
Power Consumption (Overall Max)* 235W 260W
*Overall Max refers to when the unit is at max brightness and the following features are also active: OPS Slot, External Speaker, Raspberry Pi Compute Module Slot
NOTES:
This document is intended to be used as a reference guide to supply useful information for a design or installation. It is not intended to be a step-by step procedure for installation.
Any ceilings or walls must be strong enough to support the monitor and the installation must be in accordance with any local building codes. All mounts should make secure contact to wood studs.
4:3 sources can be displayed on the 16:9 screen in either normal aspect ratio with bars on the left or right, or stretched horizontally to fill the screen using the menus (see “Aspect Modes” in menus and user manual).
Distances are in inches, for millimeters multiply by 25.4.
Tilt Angle and Rotation
Monitor may be angled and rotated from normal landscape and portrait orientation to both face up and face down positioning. Rotate only clockwise for portrait orientation.
Display Resolution 1920 x 1080 at 60Hz
Maximum Supported Resolution 3840 x 2160 at 30Hz
Power Consumption (Typical) 75W 92W
BTU's (Typical) 255.91 BTU/hr 313.92 BTU/hr
BTU’s (Max Brightness) 324.15 BTU/hr 392.40 BTU/hr
BTU’s (Overall Max)* 801.85 BTU/hr 887.15 BTU/hr
Net Dimensions 36.1 x 20.9 x 2.2 in. / 918.0 x 530.6 x 54.7mm
Net Weight 40.3lbs. / 18.3kg
Rev 1.0
Page 2
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Ventilation Recommendations:
Dimensions below are recommended for proper ventilation when the unit is in a recessed area.
NOTE:
The ventilation space should not be covered or closed off at the front of the opening. If for some reason the opening needs to be covered, other means of ventilation will need to be incorporated into the design. Contact NEC for design review and recommendations.
Rev 1.0
Page 3
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Display dimensions:
Rev 1.0
Page 4
V404/P404 Installation Guide
40” LCD Display
Display dimensions (cont.):
NEC Display Solutions of America, Inc.
Rev 1.0
Page 5
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Display Dimensions (with ST-401 stand):
NOTE:
The ST-401 optional stand attaches to the VESA hole pattern on the back of the display and can be set so the display is either 30mm or 50mm from the tabletop
Rev 1.0
Page 6
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Optional Table Top Stand Dimensions (ST-322):
NOTE:
The Pole of the ST-401 stand connects directly to the VESA hole pattern on the back of the display.
Rev 1.0
Page 7
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Dimensions of Optional Wall Mount Kit (WMK-4655S):
Rev 1.0
Page 8
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Compute Module Integration:
Door on the back of the display can be opened by loosening captive screws.
Separate IO Board is necessary to accompany RPi Compute Module in unit
Rev 1.0
Page 9
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Control Codes:
NOTE: Contact your NEC rep for codes not listed.
Cable Connection:
Communication Protocol:
Interface: RS-232C Communication System: Asynchronous Baud Rate: 9600 bps Data Length: 8 bits Parity: None Stop Bit 1 bit Communication Code: ASCII
Interface: Ethernet (CSMA/CD Communication System: TCP/IP (Internet Protocol Suite) Communication Layer: Transport layer (TCP) IP Address: 192.168.0.10 (default out of box) Port Number: 7142 (Fixed)
NOTE: If so desired, jumper “Request to send” and “Clear to Send” together on both ends of the cable to simplify cable connection. These connections are not required. The only connections required are pins 2 (TxD), 3 (RxD) and 5 (GND).
Transmit Data+ Transmit Data­Receive Data+
Not Used Not Used Receive Data­Not Used Not Used
Rev 1.0
Page 10
NEC Display Solutions of America, Inc.
V404/P404 Installation Guide
40” LCD Display
Input Panel (Bottom)
Input Panel (Side - Rotated)
Browser Control
Information and control can also be available through the HTTP browser control menu. In order to accomplish this, type: http://<the Monitor’s IP address>/pd_index.html Note that the LAN Power needs to be turned on in order for the display to be controlled while the units are off. All displays are set to the IP address 192.168.0.10 as default. Note that Media Player has separate IP Address menu that can be accessed from the Monitor’s menu or directly using separate IP Address. IP Address for Media Player is set to 192.168.0.110 for default configuration Communicating network PC needs to be on the same subnet as display that is being communicated with
Rev 1.0
www.necdisplay.com V404/P404 Page 10 of 10
Loading...