Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your storage system.
February 13, 2015 Revision 2.1
NEC Corporation
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 4
Front and Rear Views ........................................................................................................................... 4
Dimensions (mm) .................................................................................................................................. 5
UNIT CONFIGURATION .................................................................................................. 8
1 External Drive Configuration ........................................................................................................ 8
COPYRIGHT NOTICE AND LIABILITY DISCLAIMER ................................................. 12
REVISION HISTORY ..................................................................................................... 13
NEC Corporation Revision 2.1 – February 13, 2015 2
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Model
2U SAS JBOD Enclosure
Part Number
N8192-101F
N8192-102F
Storage
Maximum Capacity
28.8 TB SAS
48 TB NL SAS
Hot Plug
Supported
Drive Bays
24
12
Interfaces
One SFF-8088 mini-SAS Connector
Redundant Power Supply
Standard, hot plug
Power Supply
Two hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Maximum Power Consumption
300 Watt
310 Watt
Dimensions (W x D x H )
455.0 x 569.0 x 88 mm / 17.9 x 22.4 x 3.4 in (2U)
Weight (Maximum)
29 kg, 63.93 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%

Technical Specification

Key Features

Compact direct attached storage Twenty four 2.5-inch or twelve 3.5-inch drive bays in 2U enclosure Superior reliability with hot plug redundant power supplies and redundant fans

Specification

NEC Corporation Revision 2.1 – February 13, 2015 3
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Legend
A.
ID LED
E.
Hard Drive Activity LED
B.
Service LED
F.
Hard Drive Fault LED
C.
Power LED
G.
Drive Bays
D.
Standby LED
A
B C
D
G
E F
A
B C
D
G
FE

External Views

Front and Rear Views

Front View

2U 2.5-inch SAS JBOD Enclosure
2U 3.5-inch SAS JBOD Enclosure
Optional Front Bezel Installed
NEC Corporation Revision 2.1 – February 13, 2015 4
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Legend
A.
Power Switch
H.
Controller Ready LED
B.
AC Inlet
I.
Controller Fault LED
C.
AC Power Good LED
J.
ID LED
D.
Power Fault LED
K.
SAS Link LED
E.
Service Action LED
L.
SAS Fault LED
F.
DC Power Good LED
M.
SFF-8088 mini-SAS Connector
G.
Standby Power Good LED
B
C
D
E
F
G
A
LH M
I
J K

Rear View

NEC Corporation Revision 2.1 – February 13, 2015 5
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure

Dimensions (mm)

2U 2.5-inch SAS JBOD Enclosure

NEC Corporation Revision 2.1 – February 13, 2015 6
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure

2U 3.5-inch SAS JBOD Enclosure

NEC Corporation Revision 2.1 – February 13, 2015 7
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID0/1/5/6)
LSI MegaRAID SAS 9285-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s,
SATA 6Gb/s
N8103-160
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9286CV-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 3.0 x8, SAS 6Gb/s,
SATA 6Gb/s, flash cache protection modules included
N8103-161
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9285-8e
N8103-162
Cable
1 to 2 Required
External SATA Cable
2 m, 1 x SFF-8088 to 1 x SFF-8088
K410-191(02)
Enclosure
1 to 2 Required
2U 2.5-inch SAS JBOD Enclosure
24 x 2.5-inch Hot-plug hard drive bays
N8192-101F
Bezel
Front Bezel
For N8192-101F/102F
N8192-302F
Drive
24 slots available
300GB HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-501
450GB HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-502
600GB HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-503
900GB HDD
1 x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-504
1.2TB HDD
1 x 1.2 TB, SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-508

Unit Configuration

1 External Drive Configuration

1.1 2U 2.5-inch SAS JBOD Enclosure (1)

NOTE:
Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Eight and more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
NEC Corporation Revision 2.1 – February 13, 2015 8
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash cache protection modules included
N8103-179
Cable
1 to 2 Required
External SATA Cable
2 m, 1 x SFF-8088 to 1 x SFF-8644
K410-322(02)
Enclosure
1 to 2 Required
2U 2.5-inch SAS JBOD Enclosure
24 x 2.5-inch Hot-plug hard drive bays
N8192-101F
Bezel
Front Bezel
For N8192-101F/102F
N8192-302F
Drive
24 slots available
300GB HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-501
450GB HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-502
600GB HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-503
900GB HDD
1 x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-504
1.2TB HDD
1 x 1.2 TB, SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-508

1.2 2U 2.5-inch SAS JBOD Enclosure (2)

NOTE:
Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Eight and more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
NEC Corporation Revision 2.1 – February 13, 2015 9
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID0/1/5/6)
LSI MegaRAID SAS 9285-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s
N8103-160
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9286CV-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 3.0 x8, SAS 6Gb/s, SATA 6Gb/s, flash cache protection modules included
N8103-161
RAID BBU
Recommended for N8103-160
RAID Battery Backup Unit
for N8103-160 LSI MegaRAID SAS 9285-8e
N8103-162
Cable
1 to 2 Required
External SATA Cable
2 m, 1 x SFF-8088 to 1 x SFF-8088
K410-191(02)
Enclosure
1 to 2 Required
2U 3.5-inch SAS JBOD Enclosure
12 x 3.5-inch Hot-plug hard drive bays
N8192-102F
Bezel
Front Bezel
For N8192-101F/102F
N8192-302F
Drive
12 slots available
1TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 1 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-505
2TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 2 TB NL SAS HDD,32.5-inch, 6Gb/s, 7,200 rpm
N8192-506
3TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 3 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-507
4TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 4 TB, NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-509

1.3 2U 3.5-inch SAS JBOD Enclosure (1)

NOTE:
Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Four or more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
NEC Corporation Revision 2.1 – February 13, 2015 10
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash cache protection modules included
N8103-179
Cable
1 to 2 Required
External SATA Cable
2 m, 1 x SFF-8088 to 1 x SFF-8644
K410-322(02)
Enclosure
1 to 2 Required
2U 3.5-inch SAS JBOD Enclosure
12 x 3.5-inch Hot-plug hard drive bays
N8192-102F
Bezel
Front Bezel
For N8192-101F/102F
N8192-302F
Drive
12 slots available
1TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 1 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-505
2TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 2 TB NL SAS HDD,32.5-inch, 6Gb/s, 7,200 rpm
N8192-506
3TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 3 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-507
4TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 4 TB, NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-509

1.4 2U 3.5-inch SAS JBOD Enclosure (2)

NOTE:
Storage controllers must be compatible with the server connected. The drive enclosures connected to one storage controller must be identical. One drive enclosure can be connected to one port of storage controller. Four or more disk drives must be installed. All hard drives within a RAID array should be of the same capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
NEC Corporation Revision 2.1 – February 13, 2015 11
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure

Copyright Notice and Liability Disclaimer

The information contained herein is subject to change without notice. All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein.
NEC Corporation Revision 2.1 – February 13, 2015 12
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
Revision
Date
Description
3.0
February 13, 2015
Other:
Corrected the type of SAS cable to connect with N8103-179 RAID Controller and JBOD
2.0
January 30, 2015
New products added:
RAID Controller (2GB, RAID0/1/5/6) / N8103-179
1.0
December 26, 2013
Initial release

Revision History