Nec 2464, 1232, 824, 308 INSTALLATION MANUAL

HYBRID TELEPHONE SYSTEM
GROUPHONE
Issue-1
December, 1998
INSTRUCTION
AND
INSTALLATION MANUAL
Model 308/824/1232/2464
Issue No. Date
1 December, 1998 1st release for following ROM version:
TX-Z 308: 3.0 TX-Z 824: 5.0 TX-Z 1232/2464: 3.0 (CPU-B1)
Remarks
Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a warranty of, or representation with respect to, any of the equipment covered. This manual is subject to change without notice and Nitsuko has no obligation to provide any updates or corrections to this manual. Further, Nitsuko also reserves the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No representation is made that this manual is complete or accurate in all respects and Nitsuko shall not be liable for any errors or omissions. In no event shall Nitsuko be liable for any incidental or consequential damages in connection with the use of this manual. No part of this document may be photocopied or reproduced without prior written consent of Nitsuko.
(C) 1998 by Nitsuko Corporation. All Rights Reserved.
Printed in Japan
This manual consists of eight parts:
PART 1: INTRODUCTION PART 2: SPECIFICATIONS PART 3: SYSTEM INSTALLATION PART 4: FEATURE DESCRIPTION AND OPERATION PART 5: SYSTEM PROGRAMMING PART 6: PROGRAM RECORD FORM PART 7: OPTIONAL ITEMS (Caller-ID, FAXU, VAU) PART 8: HOW TO USE FOR SINGLE LINE TELEPHONE
PART 1
INTRODUCTION
The TX-Z 308/824/1232/2464 system is a microprocessor-based, state-of-the-art communications system which offers you superb service, and the flexibility and featur es which are usually only found on larger, more expensive systems.
The TX-Z 308/824/1232/2464 system is designed to give you the best custom-designed services available, making it as easy to use as it is to install. The system can operate by itself or behind a Private Branch Exchange (PBX). The TX-Z 308 system is ideal choice for small or home office. It starts with three lines and eight extensions. TX-Z 824 system can grow in size from the basic four outside lines and eight extensions to eight outside lines and twenty-four extensions. Main Equipment for TX-Z 1232/2464 system is slot type expansion cabinet and expandable using one cabinet. This system can grow in size from twelve outside lines and thirty-tw o extensions to tw enty­four outside lines and sixty-four extensions only adding expansion mother board and power supply unit.
With the touch of a few keys, you will have such sophisticated features as Abbreviated Dialing, Repeat Dialing, Conference Call, and Paging etc. at your fingertips. You can also have text message with display phone!
The possibilities are almost limitless. The system offers you t he flexible assignment of outside lines, and a toll restriction package that can be tailored to suit your needs. Optional equipments (Doorphone, BGM/External MOH input, External Paging output, SMDR I/F, Fax Machine, Voice Mail) can be installed if you desire. Such options are guaranteed to expand and enrich the already wide horizons of your system.
One of the excellent points about TX-Z 308/824/1232/2464 system are powerful features provided for single line telephone. Most of features provided for key telephone can be used on single line telephone. Also, you do not need exclusive interface unit to connect single line telephones to TX-Z 308/824/1232/2464 system. It means that y ou can use t he same interface unit as key t elephone.
This manual will provide you with step-by-step instructions for the installation of the basic equipment, the procedure for customizing your system so that it serves your office or company's particular needs, and the easy, almost effortless instructions for using your t elephones.
NOTE:
equipment or attempting any installation.
Please read through this entire manual at least once before ordering any additional
PART 2
SPECIFICATIONS
General Description System Configuration Visual Indication Audible Indication
General Description
System Capacity
Items TX-Z 308 System
System Size 308 Trunk Line 3 Extension 8
Key Telephone Max. 7 (No. 10 to No. 16)
Single Line Telephone Max. 6 (No. 12 to No. 17) Intercom Talk Path 2 Paging Path 1 DTMF Receiver 2 Doorphone Interface 2 External Speaker Output 1 External MOH Input 1 PF Transfer Line 1
(Fixed to CO No. 1 to Ext. No. 17)
Items TX-Z 824 System
System Size 408 616 824 Trunk Line 4 6 8 Extension 8 16 24
Key Telephone 8 16 24
Single Line Telephone 8 16 24 DLS Console Max. 3 (Use DLS console as DSS console.) Intercom Talk Path 6 Paging Path 2 DTMF Receiver 2 4 6 Doorphone Interface 2 BGM Input 1 External Speaker Output 2 External MOH Input 1 Ringer Unit 1 PF Transfer Line 4
¾ 2-1 ¾
General Description
System Capacity
Items TX-Z 1232/2464 System
System Size 1232 2464 Trunk Line 12 24 Extension 32 64
Key Telephone 32 64
Single Line Telephone 32 64
DSS Console 1 2 Intercom Talk Path 10 Paging Path 2 DTMF Receiver 8 16 Doorphone Interface 2 BGM Input 1 External Speaker Output 2 External MOH Input 1 Ringer Unit 1 2 PF Transfer Line 12
Note:
When one DSS Console is connected, one intercom talk path is occupied. When DSS Console, Paging Path or BGM Input is used, intercom talk path(s) will be used.
¾ 2-2 ¾
General Description
Electrical Specifications
Station Cable Length Limit
Key Telephone Single Line Telephone Doorphone Box
* Off-premises extension is not allowed. In other words, do not run the wire
in outdoor.
308M 90 V AC to 264 V AC, 50/60 Hz.
Primary Power
Power Consumption
Secondary Power +5 V DC, +6 V DC, +12 V DC, +28 V DC.
824M-100 90 V AC to 134 V AC, 50/60 Hz. 824M-200 180 V AC to 264 V AC, 50/60 Hz. 2464M 90 V AC to 264 V AC, 50/60 Hz. 308 40 VA maximum. 824 85 VA maximum. 1232 195 VA maximum. 2464 390 VA maximum.
300 m (0.5 f two-pair twisted cable). 1,125 m (0.5 f one-pair twisted cable). 150 m (0.5 f one-pair twisted cable).
Power Supplies
External Equipment Specifications
Background Music (BGM) /Specifications
Input Impedance Input Level Maximum Input 1 Vrms
External Music On Hole (MOH) Specifications
Input Impedance Input Level Maximum Input 1 Vrms
External Paging Speaker Specifications
Output Impedance Output Level Maximum Output 400 mV rms
600 W Nominal 250 mV (-10 dBm).
600 W Nominal 250 mV (-10 dBm).
600 W Nominal 250 mV (-10 dBm).
¾ 2-3 ¾
General Description
Mechanical specifications
Main Equipment
Key Telephone
DSS Console
DLS Console
Doorphone Box
Items
TX-Z 308 TX-Z 824 TX-Z
1232/2464
Display Type
Standard Type
Dimensions (W
335 ´ 265 ´ 90/1.9 475 ´ 325 ´ 104/5.00
494.6 ´ 362 ´ 230/6.70
221 ´ 170 ´ 88/0.80 (TXD) 216 ´ 177 ´ 81/0.75 (BTXD) 221 ´ 170 ´ 88/0.75 (TD) 216 ´ 177 ´ 81/0.70 (BTD) 221 ´ 170 ´ 63/0.50 (64 D DSS) 216 ´ 177 ´ 59/0.50 (64 BD DSS) 221 ´ 62.5 ´ 63/0.20 (24 DL DLS) 212 ´ 60 ´ 59/0.20 (24 BDL DLS) 132 ´ 100 ´ 35/0.20
D
H mm)/Weights (Kg)
´´´´
´´´´
Environmental Specifications
Items Environmental Requir em e nt s
Temperature
Humidity 10% to 95% noncondensing.
System 0 to 45 degree C (32 to 113 degree F). Doorphone
-20 to 60 degree C (-4 to 140 degree F).
¾ 2-4 ¾
System Configuration (TX-Z 308)
Name Description
NX.E-308M TXZ ME TX-Z 308 Main Equipment 1
NX.E-6TD TXZ KTS 6 Line keys, standard type Key
Telephone NX.E-6TXD TXZ KTS 6 Line keys, display type Key Telephone NX.E-12TD TXZ KTS 12 Line keys, standard type Key
Telephone NX.E-12TXD TXZ KTS 12 Line keys, display type Key Telephone NX.E-6BTD TXZ KTS 6 Line keys, standard type Key
Telephone NX.E-6BTXD TXZ KTS 6 Line keys, display type Key Telephone NX.E-12BTD TXZ KTS 12 Line keys, standard type Key
Telephone NX.E-12BTXD TXZ KTS 12 Line keys, display type Key Telephone
NX7E-3SMDR-A1 SMDR interface card 1
Doorphone I/F, relay contacts, EXMOH NX7E-3DHEXU-A1
NX7E-3FAXU-A1 FAX Transfer /DUD Interface Card 1 NX7E-3CIDU-A1 Caller-ID Interface Card 1
NT-S-D6 2-wire doorphone box 2 DX2E-32i/NX7E
BATTERY BOX NX.E TXZ W.M.K Wall-mount bracket As
NX.E TXZ ABB.CARD SET
DX.E ABB.CARD SET
input, EXP output
External backup battery box 1
Pull-out type abbreviated dial number
card (20 pcs)
Stand type abbreviated dial number card
(20 pcs)
Quantity
/System
1 to 7
1
needed
As
needed
As
needed
Remarks
CPU, Power Supply, battery charger, 3-Trunk/8­extension interface, ringer, 1 PF transfer circuit included.
1st Model. Modular station cable
included.
2nd Model. Modular station cable
included.
Note 2 Note 2
Music source is required for EXMOH.
Note 2 Note 2
Complied with Bellcore Spec.
NP2.6 or equivalent batteries are required.
1 pce. per key telephone.
Note 1: Note 2:
The above list shows composition of a system with full capacity. A maximum of 2 out of these 4 optional cards can be installed in TX-Z 308 Main
Equipment.
<Abbreviat ions used>
EXMOH: External Music On Hold EXP: External Paging KTS: Key Telephone Set ME: Main Equipment SMDR: Station Message Detail Recording SLT: Single Line Telephone DUD: Direct Universal Dialing
¾ 2-5 ¾
System Configuration (TX-Z 824)
Name Description
NX.E-824M TXZ ME(1) TX-Z 824 Main Equipment for 100V NX.E-824M TXZ ME(2) TX-Z 824 Main Equipment for 200V
NX.E-6TD TXZ KTS NX.E-6TXD TXZ KTS 6 Line keys, display type Key Telephone NX.E-12TD TXZ KTS NX.E-12TXD TXZ KTS 12 Line keys, display type Key Telephone NX.E-6BTD TXZ KTS NX.E-6BTXD TXZ KTS 6 Line keys, display type Key Telephone NX.E-12BTD TXZ KTS NX.E-12BTXD TXZ KTS 12 Line keys, display type Key Telephone
NX7E-208E-A1 2-Trunk/8-extension card NX7E-008E-A1 8-extension card
NX7E-4PFU-A1 4 PF transfer card 1
NX7E-8DHEXU-A1
NX7E-8RGU-A1 Ringer unit for Single Line Telephone 1
NX7E-8SMDR-A1 SMDR interface card
NX7E-8SMCID-A1 Caller-ID/SMDR interface card
NX7E-8CID ADAPTOR Caller-ID adapter 1
NX.E-24DL TXZ DLS
NX.E-24BDL TXZ DLS NT-S-D6 2-wire doorphone box 2 8DHEXU is required. NVM-2 Model 1
NVM-2 Model 2
NVM-22
Voice Mail I/F Voice Mail Interface Unit DX2E-32i/NX7E
BATTERY BOX
6 Line keys, standard type Key
Telephone
12 Line keys, standard type Key
Telephone
6 Line keys, standard type Key
Telephone
12 Line keys, standard type Key
Telephone
Doorphone I/F, relay contacts
EXMOH/BGM input, EXP output
24 key DLS Console for 1st Model Key
Telephone (used as DSS Console)
24 key DLS Console for 2nd Model Key
Telephone (used as DSS Console)
Voice Mail with 2 ports, 2 hour voice
storage, 50 mailboxes.
Voice Mail with 4 ports, 4 hour voice
storage, 50 mailboxes.
Voice Mail with 2-4 ports, 25 hour voice
storage, 50-100 mailboxes.
External backup battery box 1
Quantity
/System
1
24
2
1
1
3
As
needed
As
needed
As
needed
As
needed
Remarks
CPU, Power Supply, battery charger, and 4­Trunk/8-extension interface included.
1st Model. Modular station cable
included.
2nd Model. Modular station cable
included.
4 power failure transfer circuits for SLT.
Music sources are required for EXMOH, BGM.
1 pce. for a system when SLT is connected.
Needed to use SMDR printer.
Needed to use Caller­ID/SMDR
1 set for 8 Trunk lines Complied with Bellcore
Spec.
Connected to display type key telephone.
1 Voice Mail I/F is required for 2 ports.
1 Voice Mail I/F is required for 2 ports.
1 Voice Mail I/F is required per port.
Required for VM connection
NP2.6 or equivalent batteries are required.
¾ 2-6 ¾
System Configuration (TX-Z 824)
Name Description
NX.E TXZ W.M.K Wall-mount bracket NX.E TXZ
ABB. CARD SET DX.E
ABB. CARD SET
NOTE:
The above list shows composition of a system with full capacity.
Pull-out type abbreviated dial number
card (20 pcs)
Stand type abbreviated dial number card
(20 pcs)
Quantity
/System
As
needed
As
needed
As
needed
Remarks
1 pce. per key telephone.
¾ 2-7 ¾
System Configuration (TX-Z 1232/2464)
Name Description
NX.E-2464M TXZ ME TX-Z 1232/2464 Main Equipment 1 1
NX7E-12MB Basic mother board NX7E-12PS Power supply unit
NX7E-24POWU DC/DC power supply, battery charger NX7E-24EPMB-A1 Expansion mother board for 2464 NX7E-12PS Expansion power supply unit for 2464
NX7E-24CPU-B1 System main processing unit 1 1
NX7E-408U-A1 4-Trunk/8-extension card NX7E-008U-A1 8-extension card
NX7E-24DHU-A1 2-doorphone I/F card 1 1 Daughter board for 24CPU NX7E-24SMDR-A1 SMDR interface card NX7E-24SMCID-A1 Caller-ID/SMDR interface card
NX7E-8CID Adapter Caller-ID adapter 2 3
NX7E-12PFU-A1 12-Trunk line PF transfer card 1 1 NX7E-24VAU-A1 Voice announce unit 1 1 NX7E-8RGU-A1 Ringer unit for Single Line Telephone 1 2 DX2E-32i/NX7E
BATTERY BOX NT-S-D6 2-wire doorphone box 2 2 24DHU is required.
NVM-2 Model 1
NVM-2 Model 2
NVM-22
Voice Mail I/F Voice Mail Interface Unit
NX.E-24DL TXZ DLS
NX.E-24BDL TXZ DLS
NX.E-64D TXZ DSS
NX.E-64BD TXZ DSS
External backup battery box 1 1
Voice Mail with 2 ports, 2 hour voice storage, 50 mailboxes.
Voice Mail with 4 ports, 4 hour voice storage, 50 mailboxes.
Voice Mail with 2-4 ports, 25 hour voice storage, 50-100 mailboxes.
24 key DLS console for 1st Model Key Telephone
24 key DLS console for 2nd Model Key Telephone
64 key DSS console for 1st Model Key Telephone
64 key DSS console for 2nd Model Key Telephone
Quantity
/System
1232 2464
1
-
1
-
48
11
As
needed
As
needed
As
needed
As
needed
816
12
Remarks
Factory equipped units
BGM and EXMOH input, 2 relay contacts, and Caller­ID software included.
Can not be installed to Slot No.4 and No.8.
Needed to use Caller-ID 1 set for 8 Trunk lines Complied with Bellcore
Spec. 12 power failure transfer
circuits for SLT.
Common unit with TX-Z 824
NP2.6 or equivalent batteries are required.
1 Voice Mail I/F is required for 2 ports.
1 Voice Mail I/F is required for 2 ports.
1 Voice Mail I/F is required per port.
Required for VM connection
Connected to display type Key Telephone
Included in the extension quantity
¾ 2-8 ¾
System Configuration (TX-Z 1232/2464)
Name Description
NX.E-6TD TXZ KTS NX.E-6TXD TXZ KTS 6 Line keys, display type Key Telephone NX.E-12TD TXZ KTS
NX.E-12TXD TXZ KTS
NX.E-6BTD TXZ KTS NX.E-6BTXD TXZ KTS 6 Line keys, display type Key Telephone NX.E-12BTD TXZ KTS
NX.E-12BTXD TXZ KTS
NX.E TXZ W.M.K Wall-mount bracket NX.E TXZ
ABB. CARD SET DX.E
ABB. CARD SET
6 Line keys, standard type Key Telephone
12 Line keys, standard type Key Telephone
12 Line keys, display type Key Telephone
6 Line keys, standard type Key Telephone
12 Line keys, standard type Key Telephone
12 Line keys, display type Key Telephone
Pull-out type abbreviated dial number card (20 pcs)
Stand type abbreviated dial number card (20 pcs)
Quantity
/System
1232 2464
32 64
As
needed
As
needed
As
needed
Remarks
1st Model. Modular station cable
included.
2nd Model. Modular station cable
included.
1 pce. per key telephone.
¾ 2-9 ¾
1. LED Indication (KTS) LED Category Interval (sec) Location
Trunk Line Incoming Call 60 IPM Flash
Trunk Line Hold 120 IPM Flash
Visual Indication
Line
ICM
Trunk Line I-Hold 300 IPM Flutter
Trunk Exclusive Hold 120 IPM Flicker
Trunk Line Busy
Intercom Incoming Call 300 IPM Flutter
Intercom Hold 120 IPM Flicker
Intercom Busy
Steady
Steady
TRFR
Call Forward Transferred Extension/Follow-Me Transferred Extension
Call Forward Originating Extension/Follow-Me Originating Extension
Night Service (Manual)
Night Service (Automatic)
300 IPM Flutter
60 IPM Flash
Steady
120 IPM Flash
¾ 2-10 ¾
Visual Indication
LED Category Interval (sec) Location
Do Not Disturb Steady
Trunk Line DND 120 IPM Flash
DND
Executive Call Forward Transferred Extension
DND Message in Active
Microphone Off Steady
Monitored Extension (BTD, BTXD TEL)
Monitoring Extension (BTD, BTXD TEL)
SPK Speaker On Steady
60 IPM Flash
120 IPM Flicker
300 IPM FlutterMIC
120 IPM Flicker
MW
MON
Message Waiting Received (TD, TXD TEL)
Message Waiting Originated
(TD, TXD TEL)
Monitored Extension (TD, TXD TEL)
Monitoring Extension (TD, TXD TEL)
120 IPM Flicker
120 IPM Flicker
300 IPM Flutter
120 IPM Flicker
¾ 2-11 ¾
Visual Indication
LED Category Interval (sec) Location
DSS
(BLF)
Indica
-tor
Extension Busy/Intercom Incoming/DND Extension
Message Waiting Received (BTD, BTXD TEL)
Message Waiting Originated
(BTD, BTXD TEL) Intercom Line Incoming
Call (BTD, BTXD TEL)
Trunk Line Incoming Call (BTD, BTXD TEL)
Steady
120 IPM Flicker
120 IPM Flicker
300 IPM Flutter
60 IPM Flash
¾ 2-12 ¾
2. LED Indication (DLS) LED Category Interval (sec) Location
Extension Busy St eady
Visual Indication
DLS
(824)
DLS (1232) (2464)
Intercom Incoming Called Extension
DND Extension
Trunk Line Incoming Call 60 IPM Flash
Trunk Line Hold 120 IPM Flash
Trunk Line I-Hold 300 IPM Flutter
Trunk Line Exclusive Hold 120 IPM Flicker
120 IPM Flash
300 IPM Flutter
Trunk Line Busy
Steady
¾ 2-13 ¾
Audible Indication
1. Tone Interval Indication ( KTS) Category Interval (sec) Location
Trunk Line Incoming Call 600/450/16 Hz FM
Trunk Line Off-Hook Signal Tone (Speaker Busy)
Trunk Line Automatic Recall 600/450/16 Hz FM
Three-Minute Tone 600 Hz 3 Splash
Toll Restriction and Each Password Entry Failed
Line Available in Trunk Queuing 600/450/16 Hz FM
Paging/Doorphone Splash Tone 800 Hz 2 Splash
600/450/16 Hz FM
600 Hz 1 Splash
Intercom Call (Voice) Splash Tone (MIC ON)
Intercom Call (Voice) Splash Tone (MIC OFF)
Intercom Signal Call 450/16 Hz AM
Intercom Off-Hook Signaling Tone 450/16 Hz AM
¾ 2-14 ¾
800 Hz 1 Splash
800 Hz 2 Splash
Audible Indication
Category Interval (sec) Location
Intercom Off-Hook Signaling Tone (DSS Console)
Intercom Ring-Back Tone 450/16 Hz AM
Intercom Dial Tone 400 Hz
Intercom Busy Tone 400 Hz
Intercom DND Tone 400 Hz
Intercom Unobtainable Tone 400 Hz
450/16 Hz AM
Intercom Callback Recall 600/450/16 Hz FM
Emergency Alarm 1
Emergency Alarm 2
Alarm Clock 600 Hz
Call Forward/Follow-Me Accepted 600 Hz 1 Splash
600 Hz (TEL)
800 Hz (EX-SPK)
600 Hz (TEL)
800 Hz (EX-SPK)
¾ 2-15 ¾
Audible Indication
Category Interval (sec) Location
Key Touch Tone 600 Hz 1 Splash
Call Forward/Follow-Me Denied (Toll Restriction/Each Error Tone)
Warning Tone when Dial Block is Set (No-LCD(TD, BTD) TEL)
Automatic Repeat Dial Waiting Tone 600 Hz 2 Splash
Break-In Notification Tone 400 Hz
Message Playback Confirmation Tone (TX-Z 1232/2464)
KTS Local Dial Tone 400 Hz
600 Hz 3 Splash
600 Hz 3 Splash
400 Hz
KTS Local Busy Tone 400 Hz
Long Conversation Cutoff Warning Tone
¾ 2-16 ¾
400 Hz
Audible Indication
2. Tone Interval Indication ( SLT) Category Interval (sec) Location
SLT Local Dial Tone 1
SLT Local Dial Tone 2
SLT Local Busy tone 400 Hz
Hold Transfer to Busy SLT 400 Hz
Break-In Start Tone 400 Hz
Break-In Notification Tone 400 Hz
400 Hz
(#78-B=0)
400 Hz
(#78-B=1)
MW SLT Dial Tone (When SLT is Set MW)
DISA SLT Dial Tone 1
DISA SLT Dial Tone 2
SLT Ringer 1 (Trunk Calls/Doorphone Calls)
(TX-Z 308/824) SLT Ringer 1
Trunk Calls/Doorphone Calls) (TX-Z 1232/2464)
400 Hz
400 Hz
(#78-B=0)
400 Hz
(#78-B=1)
16 Hz
16 Hz
¾ 2-17 ¾
SLT Ringer 2
Audible Indication
Category Interval (sec) Location
(Intercom Calls/ Hold Transfer/ Recall) (TX-Z 308/824)
SLT Ringer 2 (Intercom Calls/Hold Transfer/
Recall) (TX-Z 1232/2464)
Message Playback Confirmation Tone (TX-Z 1232/2464)
Long Conversation Cutoff Warning Tone
16 Hz
16 Hz
400 Hz
400 Hz
¾ 2-18 ¾
PART 3
SYSTEM INSTALLATION
Precaution 3-1 Installation of TX-Z 308 System 3-2 Installation of TX-Z 824 System 3-3 Installation of TX-Z 1232/2464 System

Precaution

Please read the following notes concerning installation and connection before installing the system.
Ÿ Never attempt to insert wires, pins, etc. into the vents or other holes of this unit. Ÿ If there is any trouble, discon nect the unit from the tel ephone line. Plug the telep hone direct ly to the
telephone line. If the telephone operates properly, do not reconnect the unit to the line until the trouble has been repaired. If the telephone does not operate pr operly, the chanc es are that the tr ouble is in the telephone system, and not in the unit.
Ÿ Do not use benzine, thinner, or the l ike, or any abrasive p owder to clean the cabinet. W ipe it with a
soft cloth.
WARNING
WHEN A FAILURE OCCURS WHICH RESULTS IN THE INTERNAL PARTS BECOMING
ACCESSIBLE, DISCONNECT THE POWER SUPPLY CORD IMMEDIATELY AND RETURN THIS UNIT TO YOUR DEALER.
DISCONNECT THE TELECOM CONNECTION BEFORE DISCONNECTING THE POWER
CONNECTION PRIOR TO RELOCATING THE EQUIPMENT, AND RECONNECT THE POWER FIRST.
THIS UNIT IS EQUIPPED W ITH AN EARTHING CONTACT PLUG FOR SAF ETY REASONS
THIS PLUG MUST ONLY BE CONNECTED TO AN EARNING CONTACT SOCKET WHICH HAS BEEN INSTALLED ACCORDING TO REGULATIONS.
THE POWER SOCKET WALL OUTLET SHOULD BE LOCATED NEAR THIS EQUIPMENT
AND BE EASILY ACCESSIBL E.
TO PREVENT FIRE OR SHOCK HAZ ARD, DO NOT EX POSE THIS PROD UCT T O RAIN OR
ANY TYPE OF MOISTURE.
Precaution
Safety Installation Instructions
When installing teleph one wiring, bas ic safety prec autions sh ould always be f ollowed to re duce the risk of fire, electric shock and injury to persons, including the following:
1. Never install telephone wiring during a lightning storm.
2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
3. Never touch non-insulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
4. Use caution when installing or modifying telephone lines.
Installation Precautions
This set is exclusively made for wall mounting only. Avoid installing in the following places. (Doing so may result malfunction, noise or discoloration.)
1. In direct sunlight and hot, cold, or humid places. (Temperature range: 0°C-45°C/32°F- 113°F)
2. Sulfuric gases produced in areas where there are thermal springs, etc., may damage the equipment or contacts.
3. Places in which shocks or vibrations are frequent or strong.
4. Dusty places, or places where water or oil may come into contact with the unit.
5. Near high-frequency generating devices such as sewing machines or electric welders.
6. On or near computers telexes, or other office equipment, as well as microwave ovens or air conditioners, (It is preferable not to install in the same room with the above equipment.)
7. Install at least 1.8 m (6 feet) from radios and televisions. (both the main unit and a key telephone)
8. Do not obstruct area around the main unit (for reasons of maintenance and inspection - be especially careful to allow space for cooling above and at the sides of the main unit).
Wiring Precautions
Make sure to keep the following instructions when wiring.
1. Do no t wire the telephon e cable in p arallel with an AC power source, computer, telex, etc. If the cables are run near those wires, shi eld the cables with metal tubing or use shielded ca bles and ground the shields.
2. If cables are run on the floor, use protectors or the like to protect the wires where the y may be stepped on. Avoid wiring under carpets.
3. Avoid using the same power supply outlet for computers, telexes, and other office equipment. Otherwise, the TX-Z 308's system operation m ay be interrupt ed by the inducti on noise from suc h equipment.
4. Ple ase use one pair telephon e wire for extension con nection of (telephone) eq uipment such as standard telephones, answering machines, etc., except key telephones.
5. T he AC cord must be plugged off during wiring. After all the wiring are completed, plug t he AC cord into an AC outlet.
6. Mis-wiring may cause the system to operate improperly.
7. If an extension does not operat e properly, disconn ect the telephone f rom the extension line and then connect again, or plug off the AC cord of the system and then on again.
8. The TX-Z 308 is equipped with a 3-wire grounding type plug. This is for safety. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet.
9. Use twisted pair cable for Trunk line connection.
10.Tr unk Lines should be ins tal le d with lighting protectors. (Ask your dealer)
11.The aerial distribution wiring is not allowed.
PART3-1
INSTALLATION OF
TX-Z 308 SYSTEM
Table of Contents
Name and Location....................................................................................... 3-1-1
Wall Mounting ............................................................................................... 3-1-1
Opening Front Cover..................................................................................... 3-1-2
Frame Ground Connection ...........................................................................3-1-2
Extension Connection ................................................................................... 3-1-2
Trunk Line Connection..................................................................................3-1-4
Installation of 3SMDR and Printer/PC .......................................................... 3-1-5
Installation of 3DHEXU ................................................................................. 3-1-8
After Wiring.................................................................................................. 3-1-10
24 V DC Battery Supply.............................................................................. 3-1-11
Note: Refer to PART 7 for installation of 3CIDU-A1 and 3FAXU-A1.
Name and Location
Overview of the Main Unit Inside View of the Main Unit
Power Indicator
Initialization Switch
Extension 4-pin Jacks
Trunk 2-pin Jack
AC cord
Ground Terminal Cable Holders
Wall Mounting
Front Cover
1. Place the template (included) on the wal l to mark the four screw positions.
2. Install the four screws (included) into the wall.
3. Hook the main unit on the screw heads.
¾
3-1-1
¾
Loading...