The CD4013B dual D flip-flop is a monolithic complementary MOS (CMOS) integrated circuit constructed with N- and
P-channel enhancement mode transistors. Each flip-flop
has independent data, set, reset, and clock inputs and ‘‘Q’’
and ‘‘Q
’’ outputs. These devices can be used for shift regis-
ter applications, and by connecting ‘‘Q
’’ output to the data
input, for counter and toggle applications. The logic level
present at the ‘‘D’’ input is transferred to the Q output during
the positive-going transition of the clock pulse. Setting or
resetting is independent of the clock and is accomplished
by a high level on the set or reset line respectively.
Connection Diagram
Dual-In-Line Package
Features
Y
Wide supply voltage range3.0V to 15V
Y
High noise immunity0.45 VDD(typ.)
Y
Low power TTLfan out of 2 driving 74L
compatibilityor 1 driving 74LS
Applications
Y
Automotive
Y
Data terminals
Y
Instrumentation
Y
Medical electronics
Y
Alarm system
Y
Industrial electronics
Y
Remote metering
Y
Computers
Order Number CD4013B
Top View
TL/F/5946– 1
Truth Table
²
CL
L 00001
L10010
Kx00QQ
xx1001
xx0110
xx1111
No change
e
²
Level change
e
Don’t care case
x
C
1995 National Semiconductor CorporationRRD-B30M105/Printed in U. S. A.
TL/F/5946
DRSQQ
Page 2
Absolute Maximum Ratings (Notes1&2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
DC Supply Voltage (V
DD
Input Voltage (VIN)
Storage Temp. Range (TS)
)
b
0.5 VDCtoa18 V
b
0.5 VDCto V
a
0.5 V
DD
b
65§Ctoa150§C
DC
DC
Power Dissipation (PD)
Dual-In-Line700 mW
Small Outline500 mW
Lead Temperature (T
(Soldering, 10 seconds)260
)
L
C
§
DC Electrical Characteristics CD4013BM (Note 2)
SymbolParameterConditions
I
DD
V
V
V
V
I
OL
I
OH
I
IN
Quiescent Device V
CurrentV
Low Level
OL
Output VoltageV
High Level
OH
Output VoltageV
Low Level
IL
Input VoltageV
High Level
IH
Input VoltageV
Low Level Output V
Current (Note 3)V
High Level Output V
Current (Note 3)V
Input CurrentV
e
DD
e
DD
e
V
DD
k
I
l
l
O
e
DD
e
V
DD
e
V
DD
k
I
l
l
O
e
DD
e
V
DD
e
V
DD
k
I
l
l
O
e
DD
e
V
DD
e
V
DD
k
I
l
l
O
e
DD
e
V
DD
e
V
DD
e
DD
e
DD
e
V
DD
e
DD
e
DD
e
V
DD
e
DD
e
V
DD
e
5V, V
10V, V
15V, V
1.0 mA
5V0.050.050.05V
10V0.050.050.05V
15V0.050.050.05V
1.0 mA
5V4.954.954.95V
10V9.959.959.95V
15V14.9514.9514.95V
1.0 mA
5V, V
10V, V
15V, V
1.0 mA
5V, V
10V, V
15V, V
5V, V
10V, V
15V, V
5V, V
10V, V
15V, V
15V, V
15V, V
VDDor V
IN
e
IN
e
IN
e
O
e
O
e
O
e
O
e
O
e
O
e
O
e
O
e
O
e
O
e
O
e
O
e
IN
e
IN
SS
VDDor V
SS
VDDor V
SS
0.5V or 4.5V1.51.51.5V
1.0V or 9.0V3.03.03.0V
1.5V or 13.5V4.04.04.0V
0.5V or 4.5V3.53.53.5V
1.0V or 9.0V7.07.07.0V
1.5V or 13.5V11.011.011.0V
0.4V0.640.510.880.36mA
0.5V1.61.32.250.9mA
1.5V4.23.48.82.4mA
4.6V
9.5V
13.5V
0V
15V0.110
Recommended Operating
Conditions
DC Supply Voltage (VDD)
Input Voltage (VIN)0V
Operating Temperature Range (TA)
CD4013BM
CD4013BC
b
55§C
MinMaxMinTypMaxMinMax
1.01.030mA
2.02.060mA
4.04.0120m A
b
0.64
b
1.6
b
4.2
b
0.1
(Note 2)
a
b
0.51b0.88
b
1.3b2.25
b
3.4b8.8
b
a
25§C
b
5
b
10
0.1
b
5
0.11.0mA
3VDCtoa15 V
to VDDV
DC
b
55§Ctoa125§C
b
40§Ctoa85§C
a
125§C
b
0.36mA
b
0.9mA
b
2.4mA
b
1.0mA
DC
DC
Units
DC Electrical Characteristics CD4013BC (Note 2)
SymbolParameterConditions
I
DD
V
OL
V
OH
V
IL
Quiescent Device V
CurrentV
Low Level
Output VoltageV
High Level
Output VoltageV
Low Level
Input VoltageV
e
DD
e
DD
e
V
DD
k
I
l
l
O
e
DD
e
V
DD
e
V
DD
k
I
l
l
O
e
DD
e
V
DD
e
V
DD
k
I
l
l
O
e
DD
e
V
DD
e
V
DD
e
5V, V
10V, V
15V, V
1.0 mA
5V0.050.050.05V
10V0.050.050.05V
15V0.050.050.05V
1.0 mA
5V4.954.954.95V
10V9.959.959.95V
15V14.9514.9514.95V
1.0 mA
5V, V
10V, V
15V, V
VDDor V
IN
e
IN
e
IN
e
O
e
O
e
O
SS
VDDor V
SS
VDDor V
SS
0.5V or 4.5V1.51.51.5V
1.0V or 9.0V3.03.03.0V
1.5V or 13.5V4.04.04.0V
2
b
40§C
a
25§C
a
85§C
MinMaxMinTyp MaxMinMax
4.04.030mA
8.08.060mA
16.016.0120m A
Units
Page 3
DC Electrical Characteristics CD4013BC (Note 2) (Continued)
b
SymbolParameterConditions
40§C
MinMaxMinTypMaxMinMax
V
I
OL
I
OH
I
IN
High Level
IH
Input VoltageV
Low Level Output V
Current (Note 3)V
High Level Output V
Current (Note 3)V
Input CurrentV
Note 1: ‘‘Absolute Maximum Ratings’’ are those values beyond which the safety of the device cannot be guaranteed, they are not meant to imply that the devices
should be operated at these limits. The tables of ‘‘Recommended Operating Conditions’’ and ‘‘Electrical Characteristics’’ provide conditions for actual device
operation.
Note 2: V
Note 3: I
e
0V unless otherwise specified.
SS
and IOLare measured one output at a time.
OH
AC Electrical Characteristics* T
k
I
1.0 mA
l
l
O
e
DD
e
V
DD
e
V
DD
e
DD
e
DD
e
V
DD
e
DD
e
DD
e
V
DD
e
DD
e
V
DD
5V, V
10V, V
15V, V
5V, V
10V, V
15V, V
5V, V
10V, V
15V, V
15V, V
15V, V
e
0.5V or 4.5V3.53.53.5V
O
e
1.0V or 9.0V7.07.07.0V
O
e
1.5V or 13.5V11.011.011.0V
O
e
0.4V0.520.440.880.36mA
O
e
0.5V1.31.12.250.9mA
O
e
1.5V3.63.08.82.4mA
O
e
4.6V
O
e
9.5V
O
e
13.5V
O
e
0V
IN
e
15V0.310
IN
e
A
25§C, C
b
b
b
L
0.52
1.3
3.6
e
b
50 pF, R
0.3
e
L
SymbolParameterConditionsMinTypMaxUnits
CLOCK OPERATION
t
PHL,tPLH
t
THL,tTLH
tWL,t
WH
t
RCL,tFCL
t
SU
f
CL
Propagation Delay TimeV
Transition TimeV
Minimum ClockV
Pulse WidthV
Maximum Clock Rise andV
Fall TimeV
Minimum Set-Up TimeV
Maximum ClockV
FrequencyV
e
5V200350ns
DD
e
V
10V80160ns
DD
e
V
15V65120ns
DD
e
5V100200ns
DD
e
V
10V50100ns
DD
e
V
15V4080ns
DD
e
5V100200ns
DD
e
10V4080ns
DD
e
V
15V3265ns
DD
e
5V15ms
DD
e
10V10ms
DD
e
V
15V5ms
DD
e
5V2040ns
DD
e
V
10V1530ns
DD
e
V
15V1225ns
DD
e
5V2.55MHz
DD
e
10V6.212.5MHz
DD
e
V
15V7.615.5MHz
DD
SET AND RESET OPERATION
t
,Propagation Delay TimeV
PHL(R)
t
PLH(S)
t
,Minimum Set andV
WH(R)
t
WH(S)
C
IN
*AC Parameters are guaranteed by DC correlated testing.
Reset Pulse WidthV
Average Input CapacitanceAny Input57.5pF
e
5V150300ns
DD
e
V
10V65130ns
DD
e
V
15V4590ns
DD
e
5V90180ns
DD
e
10V4080ns
DD
e
V
15V2550ns
DD
a
25§C
b
0.44b0.88
b
1.1b2.25
b
3.0b8.8
b
5
b
b
10
0.3
b
5
0.31.0mA
200k, unless otherwise noted
a
85§C
b
0.36mA
b
0.9mA
b
2.4mA
b
1.0mA
Units
3
Page 4
Schematic Diagram
TL/F/5946– 4
TL/F/5946– 3
TL/F/5946– 2
4
Page 5
Logic Diagram
Switching Time Waveforms
TL/F/5946– 5
TL/F/5946– 6
5
Page 6
Physical Dimensions inches (millimeters)
Ceramic Dual-In-Line Package (J)
Order Number CD4013BMJ or CD4013BCJ
CD4013BM/CD4013BC Dual D Flip-Flop
NS Package Number J14A
Molded Dual-In-Line Package (N)
Order Number CD4013BMN or CD4013BCN
NS Package Number N14A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or 2. A critical component is any component of a life
systems which, (a) are intended for surgical implantsupport device or system whose failure to perform can
into the body, or (b) support or sustain life, and whosebe reasonably expected to cause the failure of the life
failure to perform, when properly used in accordancesupport device or system, or to affect its safety or
with instructions for use provided in the labeling, caneffectiveness.
be reasonably expected to result in a significant injury
to the user.
National SemiconductorNational SemiconductorNational SemiconductorNational Semiconductor
CorporationEuropeHong Kong Ltd.Japan Ltd.
1111 West Bardin RoadFax: (
Arlington, TX 76017Email: cnjwge@tevm2.nsc.comOcean Centre, 5 Canton Rd.Fax: 81-043-299-2408
Tel: 1(800) 272-9959Deutsch Tel: (
Fax: 1(800) 737-7018English Tel: (
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.