National Instruments CB-27 Installation Manual

CB-27 C
This installation guide describes how to connect the CB-27 connector block. With the CB-27 connector block, you can easily connect analog and digital signals to the following National Instruments (NI) 27-pin PCMCIA data acquisition (DAQ) devices:
DAQCard-AO-2DC
•DAQCard-500
•DAQCard-516
NI PCMCIA-4350
B
LOCKINSTALLATION
G
UIDE
Note
device user manual for compatibility information.
Other NI PCMCIA DAQ devices may be compatible with the CB-27. Refer to the
The CB-27 consists of a connector block with 28 screw terminals and a 30-position right angle connector with ejector ears. Each screw terminal corresponds to a pin number on the 30-position connector. Refer to the DAQ device user manual for connector pinout information.
Conventions
The following conventions are used in this guide:
» The » symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on the product, refer to the Read Me First: Safety and Radio-Frequency Interference document, shipped with the product, for precautions to take.
DAQCard™, National Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents inyour software, the patents.txt file on your CD, or ni.com/patents.
ni.com
© 1995–2002 National Instruments Corp. All rights reserved.
October 2002
320933C-01
bold Bold text denotes items that you must select or click in the software, such
as menu items and dialog box options. Bold text also denotes parameter names.
italic Italic text denotes variables, emphasis, a cross reference, or an introduction
to a key concept. This font also denotes text that is a placeholder for a word or value that you must supply.
monospace
Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames and extensions, and code excerpts.
What You Need to Get Started
To set up and use the CB-27, you need the following components:
A computer
CB-27 connector block
CB-27 Connector Block Installation Guide
PR27-30F I/O cable or PSH 32-30F cable (for the NI PCMCIA-4350)
CB-27 quick-reference label
One of the following devices:
NI PCMCIA-4350
DAQCard-AO-2DC
DAQCard-500
DAQCard-516
Other PCMCIA DAQ device
Read Me First: Safety and Radio-Frequency Interference
Number 2 Phillips screwdriver
1/8 in. flathead screwdriver
Tie wraps
CB-27 Connector Block Installation Guide 2 ni.com
Installing the CB-27
Caution
Refer to the Read Me First: Safety and Radio-Frequency Interference document
before removing equipment covers or connecting/disconnecting any signal wires.
To connect the CB-27 to the DAQ device, complete the following steps:
1. Insert the DAQ device into the PCMCIA slot of the computer.
2. Plug the PR27-30F into the 27-pin connector on the DAQ device or the PSH32-30F cable into the 32-pin connector on the NI PCMCIA-4350.
Caution
The PR27-30F and PSH32-30F cables are keyed so that you can insert them only one way. Do not put strain on the I/O cable when inserting it into and removing it from the DAQCard and the CB-27 connector block.
3. Connect the signals to the CB-27 connector block. Refer to the
Connecting the Signals section for instructions.
4. Insert the other end of the PR27-30F or PSH32-30F cable into the CB-27 connector. The cable connector is keyed with a centered tab that you must align with the slot on the CB-27 mating header. Firmly push in the cable connector until the ejector ears on the CB-27 connector snap into position.
Note
Make sure that the PR27-30F ribbon cable or the PSH32-30F cable is not twisted
between the DAQ device and the CB-27.
© National Instruments Corporation 3 CB-27 Connector Block Installation Guide