CB-27 C
ONNECTOR
This installation guide describes how to connect the CB-27 connector
block. With the CB-27 connector block, you can easily connect analog and
digital signals to the following National Instruments (NI) 27-pin PCMCIA
data acquisition (DAQ) devices:
• DAQCard-AO-2DC
•DAQCard-500
•DAQCard-516
• NI PCMCIA-4350
B
LOCKINSTALLATION
G
UIDE
Note
device user manual for compatibility information.
Other NI PCMCIA DAQ devices may be compatible with the CB-27. Refer to the
The CB-27 consists of a connector block with 28 screw terminals and a
30-position right angle connector with ejector ears. Each screw terminal
corresponds to a pin number on the 30-position connector. Refer to the
DAQ device user manual for connector pinout information.
Conventions
The following conventions are used in this guide:
» The » symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to
pull down the File menu, select the Page Setup item, and select Options
from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to
avoid injury, data loss, or a system crash. When this symbol is marked on
the product, refer to the Read Me First: Safety and Radio-Frequency
Interference document, shipped with the product, for precautions to take.
DAQCard™, National Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. Product and
company names mentioned herein are trademarks or trade names of their respective companies. For patents covering
National Instruments products, refer to the appropriate location: Help»Patents inyour software, the patents.txt file
on your CD, or ni.com/patents.
ni.com
© 1995–2002 National Instruments Corp. All rights reserved.
October 2002
320933C-01

bold Bold text denotes items that you must select or click in the software, such
as menu items and dialog box options. Bold text also denotes parameter
names.
italic Italic text denotes variables, emphasis, a cross reference, or an introduction
to a key concept. This font also denotes text that is a placeholder for a word
or value that you must supply.
monospace
Text in this font denotes text or characters that you should enter from the
keyboard, sections of code, programming examples, and syntax examples.
This font is also used for the proper names of disk drives, paths, directories,
programs, subprograms, subroutines, device names, functions, operations,
variables, filenames and extensions, and code excerpts.
What You Need to Get Started
To set up and use the CB-27, you need the following components:
❑
A computer
❑
CB-27 connector block
CB-27 Connector Block Installation Guide
❑
❑
PR27-30F I/O cable or PSH 32-30F cable (for the NI PCMCIA-4350)
❑
CB-27 quick-reference label
❑
One of the following devices:
– NI PCMCIA-4350
– DAQCard-AO-2DC
– DAQCard-500
– DAQCard-516
– Other PCMCIA DAQ device
Read Me First: Safety and Radio-Frequency Interference
❑
❑
Number 2 Phillips screwdriver
❑
1/8 in. flathead screwdriver
❑
Tie wraps
CB-27 Connector Block Installation Guide 2 ni.com

Installing the CB-27
Caution
Refer to the Read Me First: Safety and Radio-Frequency Interference document
before removing equipment covers or connecting/disconnecting any signal wires.
To connect the CB-27 to the DAQ device, complete the following steps:
1. Insert the DAQ device into the PCMCIA slot of the computer.
2. Plug the PR27-30F into the 27-pin connector on the DAQ device or the
PSH32-30F cable into the 32-pin connector on the NI PCMCIA-4350.
Caution
The PR27-30F and PSH32-30F cables are keyed so that you can insert them only
one way. Do not put strain on the I/O cable when inserting it into and removing it from the
DAQCard and the CB-27 connector block.
3. Connect the signals to the CB-27 connector block. Refer to the
Connecting the Signals section for instructions.
4. Insert the other end of the PR27-30F or PSH32-30F cable into the
CB-27 connector. The cable connector is keyed with a centered tab that
you must align with the slot on the CB-27 mating header. Firmly push
in the cable connector until the ejector ears on the CB-27 connector
snap into position.
Note
Make sure that the PR27-30F ribbon cable or the PSH32-30F cable is not twisted
between the DAQ device and the CB-27.
© National Instruments Corporation 3 CB-27 Connector Block Installation Guide