Napoleon Fireplaces WF 6, WF9, WF18 User Manual

Page 1
SERIAL / SÉRIE#______________________
INDOOR AIR QUALITY
DECORATIVE INDOOR WATERFALLS
THAT PURIFY AND HUMIDIFY THEAIR
WF 6/9/18
MANUFACTURED BY / MANUFACTURE PAR:NAPOLEON APPLIANCE CORP.,
214 BAYVIEW DR., BARRIE, ONTARIO, CANADA L4N 4Y8 PHONE: (705)726-4278
FAX:(705)725-2564 EMAIL: ask@nac.on.ca WEB SITE: www.napoleongrills.com
GARDER CE LIVRE POUR RÉFÉRENCES FUTURES
N415-0128 / MAR 16/05
Page 2
R
WATERFALLS
NAPOLEON waterfalls are manufactured under the strict Standard of the world recognized
ISO 9001-2000 Quality Assurance Certificate.
NAPOLEON products are designed with superior components and materials, and are assembled
by trained craftsmen who take great pride in their work. Every component is thoroughly in-
spected by a qualified technician before packaging and shipping to ensure that you, the
customer, receive the quality product you expect from NAPOLEON.
NAPOLEON WATERFALL PRESIDENT'S WARRANTY
NAPOLEON warrants the materials and workmanship in your new NAPOLEON Waterfall against
defects for a period of one year. This excludes filters, light bulbs, and UV light bulbs.
NAPOLEON shall not be liable for any transportation charges, labour costs, installation or removal
costs, water damage or export duties.
CONDITIONSAND LIMITATIONS
"NAPOLEON warrants its products against manufacturing defects to the original purchaser only (ie., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with NAPOLEON), provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:"
This factory warranty is non-transferable and may not be extended what-so-ever by any of our representatives.
The waterfall must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, hostile environments, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, rust, painted finishes, abrasive and chemical cleaners, nor chipping on porcelain enamel parts, nor any components used in the installation of the waterfall.
Should deterioration of parts occur to the degree of non-performance within the duration of the warranted coverage, a replacement part will be provided.
In the first year only, this warranty extends to the replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
After the first year, with respect to this President's Limited Lifetime Warranty NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
NAPOLEON will not be responsible for the installation, labour or any other costs or expenses related to the re-installation of a warranted part, and such expenses are not covered by this warranty.
Notwithstanding any provision contained in this President's Limited Lifetime Warranty NAPOLEON's responsiblity under this warranty is defined as above and it shall not in any event extend to any incidental, consequential, or indirect damages.
This warranty defines the obligation and liability of NAPOLEON with respect to the NAPOLEON waterfall and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product.
Any damages to the waterfall due to weather damage, hail, rough handling, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from NAPOLEON. The warranty registration card must be returned within fourteen days to register the warranty or you can register on-line at www.napoleongrills.com.
NAPOLEON reserves the right to have its representative inspect any product or part prior to honouring any warranty claim.
NAPOLEON shall not be liable for any transportation charges, labour costs, installation or removal cost, water damage or export duties.
2
Page 3
indoor air quality
Yournew NAPOLEON waterfall will dramatically improvethe indoor air quality inyour home. The waterfall isa natural humidifier
which helpsalleviate dry skin and allergies. This is extremely beneficial in dryclimates and also cold climateswhere forced air furnaces dry the air. The waterfall also cleansthe air by attracting contaminants. Moving water attracts airborne particles, such as dust, pet dander,pollen and other pollutants. The waterfall draws these particles into the water, which is then filtered through a 5 micron filter before being recirculated. Theresultis cleaner,fresher,humidifiedair. Waterfalls also generate negative ions. These odourless tastelessinvisible molecules are created innature as air molecules break apartdueto sunlight, radiation, and movingair and water. Researchers now believe that negative ionsaid in alleviating depression, reducingstress and boosting energy.
installation Tools and materials required
Before you begin hookingup the fountain ensure that you have access to the following materials and tools. Tools:
-utility knife
- adjustable wrench
- 3/8” nut driver
-pliers
- flat screw driver
Materials:
- saddle valve and 1/4” tubing (ice makerplumbing kit) (required if unit is being connected to house water supply)
- teflon tape
- possible additional 1/2” i.d. tubing and 3/4” i.d. tubing depending on location of unit.
- liquid TSP (Trisodium Phosphate) or TSP Substitute cleaner
appropriate location
There are several things to considerwhen choosing the appropriate locationto install your waterfall. The waterfall is designed tobe installed into a 2” x4” interior wall. Thewaterfallshould not be installed ina load bearing wall,
unless it can be framed in with proper supports and headers as required by your local building codes. Check with your local building authority for specifications. Installingthewaterfallin an exterior wall isnot recommended, as it cannot beproperly insulated. If there are no suitable alternativelocations, then the waterfall canbe installed in a 2” x6” wall using rigid foaminsulation between the exterior of the house and the back of the fountain. The waterfall cannot be installedin a 2” x 4” exterior wall.
The lights,pump and optional UV-light require power. Make sure you choosea location that has the availablepower within reach of
the supplied electrical cords. The receptaclemust be GFI (ground faultinterrupt) protected. Electrical workmust be done by a qualifiedelectrician. Check with your local building authorityforspecifications for your area. Do not runextensioncords behind walls.
An area to locate the pump module is also required. It should be located as close to the fountainas possible and in a location
that is easily accessible forservicing and maintaining the module. For every 1 foot that the pump moduleis located away from the fountain unit, 1 inch of drop is required from the fountain basin drain outlet to the pump module drain inlet.
The waterfall is designed tobe connected toawater source, to automatically refillthe basin as water evaporates,and to a drain,
in case of accidental overflow. The unit can be operated without the water source connection, but is not recommended. The water will evaporate naturally and willrequire additional water to ensureproper flow and pump operation. Damage to thepump incurred by running dry is not covered by warranty. The waterfall must be hooked-up to a drain which will allow the tank to be purged for routine cleaning, and will prevent theunit from overflowing if thefloat valve malfunctions.
Waterdamage to surrounding objects in your home is not covered in your NAPOLEON warranty. The waterfall is designed to not
splash, however if it is notproperly installed or maintained, some splashing mayoccur. Protect delicate nearby surfaces that could be damaged by splashing. Donot trim with materials that can be damaged by moisture such as particle board or MDF. It is best to install the unit in stone, marble,glass, tile etc.
Although your NAPOLEON Waterfall will be beneficial to the air quality of your home, excess moisture can lead to the formation of
mold and mildew. It is recommended that all homes have some formof humidity control and air exchange system to prevent such an occurence.
3
Page 4
water
Waterisperhapsthemost critical component in thewaterfall. Dirty orcontaminatedwater will quickly cause operationalproblems
with your waterfall. House water must be softened and filtered if the unit is to be connected to the water supply. RO (Reverse Osmosis) water will give the best results, and require the least amount of maintenance. Iftheunit is not being connected to the house supply,distilledbottledwater is recommended. The provided filter and optionalUV-lightcannotpreventhard water deposits from forming on the surfaces of your waterfall. Hard water will also cause pluggedpassagesand manifold ports, reducing the flow effect on the waterfall surface. Thelife-spanof the pump will also be adversely affected due to the use of hard water. Use of RO or distilled water is by far thebest way of ensuring yearsof carefree enjoyment from yourwaterfall.
The provided particle filter will helpprevent clogging of the manifold ports that disperse the water down the face of thewaterfall.
The water that flows down the face will attract dust, debris particles and mould spores that are floating in the air in your home. This will help to naturally filterthe air you breath andkeep your home cleaner. However thefilter will become contaminated and the water flow will be reduced overtime. We recommendthat the filter be replaced whenever the waterfall iscleaned, every 3-4 months or sooner as deemed necessary by poor water flow. Thefilters can be purchased through your authorized NAPOLEON dealer.
The optional ultraviolet-light will help destroyany green algae, bacteria, mouldor mildew found in thewater. Flowingwater is fairly
resistant to this kindof growth, but in time the water will become contaminatedand the system will have to be flushed and thor­oughly cleaned. Not only unsightly but mould and bacteria growth will plug the manifold ports, reducing the flow of water and can damage the water pump over time. The optional UV-light will help to keep your waterfall relatively maintenance free by keeping the water cleaner for a longer period of time. TheUV-bulbmustbe replaced every year to ensure proper operation. The UV-bulbsare availablefrom your authorized NAPOLEON dealer.
The waterfall is designed tobe connected directly to awater source. Waterfallsarenaturalhumidifiersfor the environment. The
amount of water the waterfall consumes daily is dependant upon how dry the air is, and how large thewaterfall surface is. Thereis a float valve that will open as the water level drops,allowing water toenter the system. Thiswillensure that the water level is kept at the height required for proper operation of the water pump. The pump should never be allowed to run dry and damage resulting from that will not be covered by warranty. If there is not a suitablewater source to behad nearby,thewaterfall can be installedas a stand-alonesystem,but the water level willhave to be monitored frequentlyand supplemented as needed.
WATER PUMPS
The water pump supplied with yourwaterfall has been selected forits high flow volume, efficiency,quietoperation and reliability.
The pump is suitable for pushing water to a height of 12 feet, however the flow is reduced greatly at that height. This must be kept in mind when finding a location for the pump and water basin, so the pump module must be located on the same floor as the fountain. The system has aflow control valve after the filter that can beadjusted to provide thedesired flow rate on the waterfall surface.
The pump must be kept submersed in water at all times while in operation. Thewater acts as a cooling agent for the pump,
preventing the pump from overheating. Lowwater levels, frequently turning the pump on and off and impurities in the water from poor waterfall maintenance will shorten thelife of the pump. Ifmaintainedproperly,thepumpwill provide years of reliable service.
If you hear excessive noise coming from your pump, check first to see that you have enough water in the basin to keep the pump
fully submerged below 1-2” of water. The pump should not be vibrating against the tub, but if it is, it can be isolated by placing a small piece of sponge between the pump and the basin. Be sure to not block or restrict in any way the pump’s water inlet.
ELECTRICAL REQUIREMENTS
The waterfall will require 2 separate 110voltelectricalreceptacles, one for the lightsandone for the water pump. GFIrecepta-
cles must be used, because of theuse of water and possibility of contact.
It is not required that the receptacles be wired ontheir own circuit, asthe pump, lights and optional UV-lightdrawvery little
current. If there isalready a heavy load elsewhereon that circuit or youhave trouble with breakers tripping,a separate circuit will need to be installed. Anycircuit wiring or GFI installation must be done by a qualifiedelectrician. Ifyouwould like to be able to turn the fountain on and off, the receptacles should be wired to a wall switch. Twowall switched receptacles are recommended, one for the pump and UV-light(optional) and one for the lights. This will allow you to turn the lights on and off independently of the fountain.
4
Page 5
INSTALLATION
The framing dimensions are included in the framing specifications drawing. Theunit is designed to be installedafterdrywalling.
For added protection water resistant drywall (green board) or cement board are recommended in the vicinityof the fountain. The fountainis designed to be attachedto the studs overthe drywall along both vertical sides of the fountainusing drywall screws. This will leave a basically flush surface to trim over. Leak test thewaterfall before fully enclosing. All trimused on the fountain should be made of real wood (not MDF), or any other material that is not damaged by moisture, with several coatsof a water proof coating (paint or urethane) depending on the desired look. The bottom piece of trim can only be nailed at the ends, because it is mounted in front of the stainless basin. It should besiliconed to the stainless basin foradditional support.
After installing the fountain, connect the piping as shown in the piping diagrams. Thetubing to connect the unit overflow to the
house drain is not supplied. If the unit is being connected to the water supply, use an ice maker plumbing kit (not supplied) to connect the water supply to the float valve. When the unit is operational, adjust the float valve so that it turns the water offwhen the top of the pump is submerged below 1-2” of water. Ensure that the wing nut on the side of the float valve is properly tightened. Connect the light wire to the terminals on thetransformer.
WATERFALL SURFACE MATERIALS
The waterfall is supplied witha stainless steel panel for the water to flow over. The surface of the stainlesssteelmust be cleaned
to remove any grease or oilymaterials left behind from themanufacturing process. The protective coatingwill also leave a residue behind. Any residue left on the surface,or oily residue from your hands, will repel the water and prevent a sheet of water from forming over the panel. Thiswill give you thin streams of water with large dry spots in between. Cleaning thepanelwith liquid TSP (orTSPSubstitute) will remove any residue or filmthat is impeding the progress of thewater. Clean the panelthoroughly two or three times before the first use.
Before starting the waterfall, the entirepanel surface should be wetdown, either by spraybottle, or wet cloth. This will help the
water to spread evenly acrossthe panel. The wave effectof water flowing down thepanel, will be attained after the panelis covered in water. The wave patterncan be adjusted by increasing or restricting the flow of water with the valve at the side of thefilter. Adjust the valve to achieve the effectthat is most pleasingto your eye. Itis importantto remember that too little water flow can causedry spotsto reappear on thesurface of the waterfall. Youcan increase the flow of water slightly until they disappear. Lightly rubbing a wet cloth or Scotchbrite pad (careful not to scratch the stainless steel surface), across the panel may be enough to remove any dry spots.
TO FOUNTAIN
FROMBASIN
TO DRAIN TO DRAIN
VALVE
FULL OPEN
GROOVEDACRYLICPANEL: An optional grooved acrylic panel which enhances the ripple effect can be purchased at your
authorized NAPOLEON dealer. It is designed to be placedin front of the stainless steel panel. This panel must be cleaned with liquid TSP (or TSP Substitute) before being placed in the unit, to prevent dust and debris from the manufacturing process from entering the water. Use caution when cleaning the grooves on the panel as the machined edges can be very sharp. The acrylic panelis supplied with double sidedtape,which is used to attachthe acrylic panel to thestainlesssteel panel. Run threestrips vertically down the panel (one at each side and one down the centre. Remove the backing, and adhere the acrylic panel to the stainlesspanel. Ensure that thebottom of the acrylic paneland the stainless panel are flush. The acrylic panel will requiremore water to achieve the same wave effect as the stainless panel, as the grooves will fill and retainwater. Again any dry spotscanbe removed by rubbing horizontally with a Scotchbrite pad.
FROMBASIN
PARTIALOPEN
TO FOUNTAIN
VALVE
5
Page 6
BACKBOARD
WF6
BACKBOARD
WF9 WF18
BACKBOARD
MORTAR
TILES
23.625”
CUSTOM SURFACEPANEL: Panels can also be made using materials such as mirror,
glass, slate, marble or ceramic tilefor display in your waterfall. If tiling, use waterproof cement board as a backer,availableat any building centre. Cut the cement board to the size of your existing stainless steel panel. Ensurethatthe tiles can be used in a wet environment. Porce­lain tiles are recommended. Tilethe surface, using thinset mortar,asyou would a ceramic tile floor or bathroom wall. Itis not necessary to leave a gap or grout line in your tile. Ensurethat the bottom edge of the tiles are flush with the bottom edge of the cement board. Youcan choose any colour or pattern that you like, to match the room or surroundings. The water will flow overthe tiles, just as it does on the stainless steel panel,but be sure to keep the edges of the tiles fairly flush to each other to prevent the water from splashing off. Surfaces less than 3/8” thick, such as glass or mirror,can be installed in front of the stainless panel. Thestainlesspanelmustbe removed for all panels thicker than 3/8” up to a maximum of 3/4”. Do not use glue to attach the tiles to the back panel, as some types of glue or epoxy will leach out into the water,causing the filter and manifold to plug.
35.250”
MORTAR
TILES
35.50”
35.250”
70.50”
MORTAR
TILES
35.50”
CLEANING AND MAINTENANCE
The waterfall should be drained and cleaned every 3-4 months, possibly more depending on the qualityof the water. The water-
fall surface can be cleaned using a warm soap and water mixture. Do not use harsh abrasive cleaners on the surface of the stainlesssteel panel or it will permanently scratch the surface. Any wiping motion shouldbe done in thedirection of the grain. If small scratches do occur,they can be blended out by gentle rubbing in the direction of the grain with a Scotchbrite pad.
The water should be completelyflushed and drained from thesystem - switch the valve to
the purge setting, and run the pump to pump the water out. Refill the tank, run the water through the fountain for 3 minutes and purge again. If calcium or hard water depositsare forming on the panel or anywhere else in the system, cycle CLR solution through the system until the deposits are removed thenpurge the system a fewtimes with water.
If there are spots on the panel that dry out, check that there are no blocked ports in the
manifold tube. Remove the three nuts that secure the tube cover,and remove the cover. Re­move the tube by flexing it out in the centre. This will allow the ends to pull out. Poke the holes out with an opened paper clip, and then flush the tube with water. Clean the angled surface that the manifold sprays onto with liquid TSP (or TSP substitute). Itis critical that this surface is extremely clean. Install the tube back into the unit, with the portsaiming straight down and refill with water. Installthe tube cover and test the unit.
MANIFOLDTUBE
TUBE COVER
FROMBASIN
TO FOUNTAIN
TO DRAIN
VALVE
PURGEPOSITION
The filter should be replaced every 3-4 months. To replace, unplug the pump. Lay a towel under the filter housing, as water will
drain out of the housing when opening. Unscrew the housing, and remove the filter. Replace with a new filter (part #N252-0001) available through your authorized NAPOLEON dealer. Push the new filter firmly onto the collar in the bottom of the housing. Screw the housing back onto the unit. This must be screwed on very tightly,or it will leak.
6
Page 7
TROUBLESHOOTING
Problem Possible Causes Solution
Waternot flowing. Pump not plugged in.
Insufficientwaterlevel. Add water to recommended level. Pump must be submerged by 1-2” at all
Waterflowcontrol valve turnedoff.
Filterplugged. Pumpis“vapour-locked”. The pump may have an air bubble in it,preventing it from pushingwater
Pump burned out. Replacepump.
Dryspotsonwaterfall surface.
Lights not working. Lights not plugged in. Pluglightsintonearestelectricalreceptacle.
(optional)
Improperstart-upprocedure.
Insufficientflow. Surfacenot cleaned
properly. Pluggedportsin manifold. Turnoffwater and remove manifold tube. Inspect andclean. See cleaning
Bulb(s)are broken. Replace light bulb(s). UV-lightnotplugged in. PlugUV-lightinto nearestelectricalreceptacle.UV-lightnotworking.
Bulb no longer good. ReplaceUV-lightbulb.
Plugpump into nearest GFI protected receptacle.
times. Turnvalvetoonposition.
Replacefilter.
through. Unplug thepump, and plug itback in several times,or momentarily turnthe valve to the purge setting.
Ensuresurface of waterfall is wet before starting by sprayingwithwater or washingwith wet cloth.
Increaseflowby opening water flow valve. Cleanwith liquidTSP(orTSPSubstitute)toremove oily residue.
instructions.
Waterleakingon floor.
Drainisgurgling. Insufficientdropfrom
Waterdrippingfrom lip oftop retainer.
Leakingconnection. Checkall connections and ensure they are tight. If leaking, re-tighten. Waterleveltoohigh. Check that the basin drain is hooked-up properly and not blocked,
Weldleakinginwaterfall housing.
Waterleakingout sides of waterfall.
fountaintobasin. P-trapcreatedin drain line. Ensurethat there is a consistent slopefrom the fountain outlet to basin inlet
Certaindrainconfigurations mayhave a tendency to gurgle.
Decorativepanelisnot touchingfront lip of retainer.
preventing water from escaping. Ensurethatthere is adequate drop from the fountain to the basin. Also check that the float valve is workingproperly andnot overfilling the basin.
Inspectwaterfall thoughly and ascertain exactly where the leak is coming from. Drain allwater,anddry thoroughly. Apply a bead of clearsilicone to the inside surface of theweld. Let stand24hours before re-filling with water.
Wipe the sides of thewaterfall frame with an oiled(WD40) rag to repel water.
Ensure there is at least 1” per foot drop fromthe fountain outlet to the basin inlet.
with no dips that would trap water. Reduce the flow through the flow control valve, orloosen the white fittingin
the left hand drain (loosen a couple of turns at a time, and then test).
Removethe panel and flex out the panel tension springs. Ensurepositive tensionon panel. Replace the decorative panel.
7
Page 8
ORDERING REPLACEMENT PARTS
Before contacting the customer service department, check theNAC web site for moreextensive cleaning, maintenance, trouble-
shooting and part replacement instructions atwww.napoleongrills.com. Contactthe factory directly for replacementpartsand warranty claims. The customer servicedepartmentis available between 9 AM and 5 PM(Eastern standard time) at 1-866-820-8686 or fax at 1-705-727-4282. Inorder to process a claim, we must be provided with the following information:
1. Model and serial number of the unit.
2. Part number and description.
3.Aconcise description of the problem ('broken' is not sufficient).
4. Proof of purchase (photocopy of the invoice).
In some cases the customer service representativemay request to have thepartsreturned to the factory forinspection, before
providing replacement parts. The parts must beshipped prepaid to the attention of the customer service departmentwith the above information.
Before contacting customer service, kindly notethat the following items arenot covered by the warranty:
-costsfor transportation,brokerage or export duties
-labour costs for removal and reinstallation
-costsforservice calls to diagnose problems
-discolorationof stainless steel parts
-partfailure due to lackof cleaning and maintenance,or use of impropercleaners.
NOTES
8
Page 9
FRAMING SPECIFICATIONS
2x6 HEADER PANEL RECOMMENDED
CHECK WITH LOCAL CODES
HEIGHT
Ø1.50”
24”
RECOMMENDED*
CHECK WITH YOUR LOCAL BUILDING AUTHORITY FOR COMPLETE FRAMING GUIDELINES. THE CHART
BELOW WILL GIVE YOU THE OPENING SIZE REQUIRED FOR EACH MODEL.
4.00” CENTERS
WF6 WF9
WF18
WIDTH
49.00”
49.00”
84.25”
WIDTHHEIGHTMODEL
26.750”
38.625”
38.625”
*Additional height may be required to ensure adequate drop to the pump module.
9
Page 10
PIPING DIAGRAM WITHOUT UV LIGHT
6X N570-0043 (8-32 X 3/4")
1
TO
ELECTRICAL
OUTLET
2
FROMTHREE
WAY VALVE TO
WATERFALL
A
FROM BASIN TO
WATERFALL DRAIN
INSTALLTHE SUPPLIED
HOSE CLAMPS ON EITHER
SIDE OF THE BASIN
CUT THE SHORT PIECE OF BLACK
TUBING TO 14”
OVERFLOW
PROTECTION
FROM WATERFALL
DRAIN TO BASIN
B
B
A
WATER
FILTER
FROM THREE WAY
VALVE TO WATERFALL
FROM WATER
SOURCE TO
FLOATVALVE
SADDLEVALVE
(NOTINCLUDED)
FLOW CONTROL
VALVE/PURGE
VALVE
TO DRAIN
PURGE LINE
REMOVE COMPONENTS FROM BASINANDASSEMBLEAS SHOWN. THE FITTINGS REQUIREDAREALREADYATTACHED
TOTHE FILTERANDBASIN. MEASUREAND CUT THE LINES TO THE LENGTH NECESSARY, PUSH ONTOTHE BARBED FITTINGSAND SECURE WITH THE SUPPLIED HOSE CLAMPS. LEAK TEST THE WA TERFALLBEFORE FULLYENCLOSING.
10
Page 11
PIPING DIAGRAM WITH UV-LIGHT
9X N570-0043 (8-32 X 3/4")
TO
ELECTRICAL
OUTLET
1
3
2
4
FROM THREE
WAY VALVE TO
WATERFALL
A
FROM BASIN TO
WATERFALL DRAIN
INSTALLTHE SUPPLIED
HOSE CLAMPS ON EITHER
SIDE OF THE BASIN
OVERFLOW
PROTECTION
TO DRAIN
FROM WATERFALL
DRAIN TO BASIN
B
B
PURGE LINE
UV
LIGHT
A
WATER
FILTER
FROM THREE WAY
VALVE TO WATERFALL
FROM WATER
SOURCE TO
FLOATVALVE
SADDLEVALVE
FLOW CONTROL
VALVE/PURGE
VALVE
REMOVE COMPONENTS FROM BASINANDASSEMBLEAS SHOWN. THE FITTINGS REQUIREDAREALREADY ATTACHED
TOTHE FILTERANDBASIN. WHEN USING THE OPTIONAL UV-LIGHT, THE BARBED ELBOW FITTING ON THE ‘IN’ SIDE OF THE FILTERWILLNEED TO BE REMOVED AND THREADED INTO THE ELBOWATTHE BOTTOM OFTHE UV-LIGHT. THENCON­NECTTHE UV-LIGHTDIRECTLYTO THE FILTER. USE TEFLON TAPETOSEALTHESE CONNECTIONS. ENSURE THATTHE SUPPLIED GROUND WIRE IS CONNECTED FROM THE GROUNDINGTERMINALON THE UV LIGHT TO EITHER GROUNDED COPPER PLUMBING,ORTHEGROUND IN YOUR ELECTRICALSYSTEM. USETHE SUPPLIED SHORT PIECE OF BLACK TUBING TO RUN FROM THE PUMP TOTHE UV LIGHT. MEASUREAND CUT THE LINES TO THE LENGTH NECESSARY, PUSH ONTO THE BARBED FITTINGS AND SECURE WITH THE SUPPLIED HOSE CLAMPS. LEAK TEST THE WATERF ALLBEFORE FULL YENCLOSING.
11
Page 12
WATERFALL SURFACE INSTALLATION
Thestainlesssteelpanelprovided with the waterfall is installed simply by sliding the topofthe panel under the retaining bracket at
the top of the waterfall, and pushing it high enough to slip over the bottom support brackets. The welded brackets that protrude at an anglefrom the waterfall housing, merely provide pressureto the panel to prevent it from bowing. The optional acrylic panel can be placed in front of the stainlesssteelpanelinthe same manner. If building your ownceramic tile or slate background, youmust remove thestainlesssteel panel, because of the thickness of the tileand cement board backing.
PARTS LIST
ITEM WF6 PART WF9 PART WF18 PART PARTS DESCRIPTION
1 n010-0446 n010-0447 n010-0448 main housing x 2 n010-0449 n 010-0450 n010-0451 water supply line assembly x 3 n432-0014 n432-0015 n432-0015 manifold x 4 n105-0008 n 105-0008 n105-0008 rubber grommet x 5 n080-0169 n080-0170 n080-0170 w ater pinch bracket x 6 n450-0009 n450-0009 n450-0009 10-24 nut x 7 n402-0006 n 402-0006 n402-0006 lighting track WF6 - 20" long WF9/18 - 32" long x 8 n402-0004 n402-0004 n402-0004 lighting track end cap x
9 n402-0005 n 402-0005 n402-0005 lighting track power connection x 10 n402-0007 n402-0007 n402-0007 light socket x 11 n402-0003 n402-0003 n402-0003 light bulb x 12 n200-0071 n200-0072 n200-0072 light cover x
n707-0002 n707-0002 n707-0002 12 volt transformer x 13 n255-0033 n255-0033 n255-0033 1/2" femalepipeto 1/2" barb adapter fitting x 14 n160-0012 n160-0012 n160-0012 5/8" hose clamp x 15 n160-0013 n160-0013 n160-0013 1" hose clam p x 16 n255-0034 n255-0034 n255-0034 3/4" bulkhead fitting x 17 n255-0037 n255-0037 n255-0037 3/4" male pipe to 3/4" barb elbow fitting x 18 n475-0149 n475-0150 n475-0151 w aterfall panel - stainless steel x
n475-0152 n475-0153 n475-0154 w aterfallpanel- black grooved acrylic ac 19 n335-0037 n335-0037 n335-0037 w ater basin lid x 20 n185-0002c n185-0002c n185-0002c water basin x 21 n255-0035 n255-0035 n255-0035 1/4" femalepipeto 1/2" barb adapter fitting x 22 n517-0001 n517-0001 n517-0001 w ater pump x 23 n725-0023 n725-0023 n725-0023 float valve x 24 n010-0443 n010-0443 n010-0443 w ater basin housing x 25 n725-0022 n725-0022 n725-0022 3-way valve x 26 n255-0041 n255-0041 n255-0041 3/4" male pipe to 1/2" barb adapter fitting x 27 n350-0052 n350-0052 n350-0052 filter housing x 28 n252-0001 n252-0001 n252-0001 replacement filter (5 micron) ac 29 n080-0177 n080-0177 n080-0177 filter mounting bracket x 30 n570-0043 n570-0043 n570-0043 8-32 x 3/4" stainless steel screw x 31 n402-0002 n402-0002 n402-0002 ultra violet light ac 32 n402-0008 n402-0008 n402-0008 ultra violet replacementbulb ac 33 n080-0171 n080-0171 n080-0171 ultra violet lightmounting bracket ac 34 n255-0042 n255-0042 n255-0042 fitting, plastic 1/2" male pipe - 1/2" barb elbow x 35 n255-0039 n255-0039 n255-0039 fitting, plastic 1/2" female pipe - 1/2" female pipe elbow ac 36 n255-0040 n255-0040 n255-0040 3/4" male pipe x 1/2" female pipe bushing x
12
x-standard x-compris ac-accessory ac - accessoires
Page 13
PARTS DIAGRAM
13
Loading...