Napoleon Fireplaces NZ6000 User Manual

0 (0)
Napoleon Fireplaces NZ6000 User Manual

2

WARNINGS & SAFETY PRECAUTIONS

W415-0594 / A / 02.15.07

3

TABLE of CONTENTS

PG 2-6 INTRODUCTION

Warnings and safety precautions Warranty

General Instructions

General Information

Care of Glass & Plated Parts

7 HI-EFFICIENCY HEATING

7-14 INSTALLATION / FRAMING

Location & Clearance Framing

Outside Combustion Air Mantel Clearance Hearth Extension

Faceplate, Uppergrill, Keystone & Door

14-18 CHIMNEY INSTALLATION

Adding Chimney Sections

Offset Chimney Installation Installing Flashing And Storm Collar Connection to a Masonry Chimney

Air Cooled Chimney Installation

18 FINISHING

Attaching the Handle and Air Control Knob

Top Firebrick and Baffle Installation

19-21 BLOWER INSTALLATION

NZ64 Blower Installation NZ 150-KT Kit

22 BLOWER REPLACEMENT NSK OPTIONAL SCREEN KIT

23-27 OPERATING INSTRUCTIONS

Operating sounds & Smells Starting a Fire

Draft Control

Fuel Loading and Burn Cycle Re-loading the fireplace Flash Fires

Overnight Burn

Ash Removal

27-28 MAINTENANCE

Run-Away or Chimney Fire

Fire Extinguishers and Smoke Detectors Door Glass / Gasket Replacement Creosote Formation And Removal

Selecting Wood

29-30 REPLACEMENTS

Replacement Parts Accessories

31TROUBLE SHOOTING

32RATING PLATE LOCATION

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

 

 

NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN.

W415-0594 / A / 02.15.07

4

NAPOLEON products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate.

NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.

NAPOLEON WOOD FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY

The following materials and workmanship in your new NAPOLEON wood fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel baffle retainer, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components, aluminum extrusion trims ashdrawer, and cast iron castings.

Electrical (110V) components and wearable parts such as blowers, thermal switch, switches, wiring, firebrick and gasketing are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty.

Labour related to warranty repair is covered free of charge during the first year. Repair work, however, requires the prior approval of an authorized company official. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer.

CONDITIONS AND LIMITATIONS

NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:

This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.

The wood fireplace must be installed by an authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes.

This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.

This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, nor any venting components used in the installation of the fireplace.

In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.

After the first year, with respect to the President's Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).

After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.

Notwithstanding any provisions contained in the President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages.

This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON wood fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.

NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.

The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.

NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.

W415-0594 / A / 02.15.07

5

INTRODUCTION

GENERAL INSTRUCTIONS

1. Combustion and dilution air is brought into the unit

4.

A single air control regulates the burn rate.

through the fresh air intake collars located on the top

5.

Inside the firebox combustion takes place and ex-

rear of the unit.

hausts out the chimney.

2. The combustion air is brought into the firebox through

6.

The optional blower can be installed to draw fresh

many small holes in the airwash located at the top and

outside air into the home (not recommended in colder

sides of the opening.

climates), then either the NZ150-KT kit or the NZ64 blower

 

3. The dilution air is introduced high in the firebox above

can be installed inside and will circulate the air into your

the baffle to cool the chimney.

home.

 

 

 

 

 

 

W415-0594 / A / 02.15.07

6

GENERAL INFORMATION

FEATURES

Maximum log length of 32"

Large firebox capacity - 4.8 cu ft.

Long burn time - up to 14 hours.

Large glass doors for maximum visibility

Firebrick lining for firebox protection

Optional 320 CFM blower for convection heat

Thermostat for automatic control of the blower

Outside air for combustion

HEATING SPECIFICATIONS

Approximate Heating Capacity up to 3,000 square feet

(Will vary with the home's floor plan, insulation and outside temperature.)

Maximum burning time up to 14 hours BTU Output per hour 10,000 to 80,000 (Cord wood method)

ELECTRICAL SPECIFICATIONS

The blower on "HIGH" draws 2.2 amps on 120 volts A.C. (approximately 250 watts).

PACKING LIST

Shipped with the fireplace:

Installation manual Baffle

Ember strip Log retainer

Flex duct w/ start collar 10' length, 6" dia (1 for NZ150-KT or blower kit and 2 for outside combustion air supplies).

Shipped with faceplate: faceplate

12 faceplate screws

Shipped with the door(s):

Installation instuctions and hardware

EPA COMPLIANCE

This heater has been certified epa exempt.

CALIFORNIA PROP 65 WARNING:

Use of this product may produce smoke which contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Do not use makeshift compromises during installation. Do not block or restrict air, grille or louvre openings! Do not add a hood.

Burning your unit with door open or ajar creates a fire hazard that may result in a house and/or chimney fire.

All venting connections must be in compliance with the chimney manufacturers installation instructions.

Clearances referred to throughout this manual are the minimum requirements.

Your Napoleon fireplace must be installed in accordance with all national and local building code standards and the standard of Chimney and Fireplaces, Vents and Solid Fuel Burning Appliances NFPA #211. Consult the authority having jurisdiction (such as municipal building department, fire department, fire prevention bureau, etc.) to determine the need to obtain a permit. If you are in doubt about the proper installation for your situation, contact your dealer or local building or fire official. The manufacturer does not guarantee that this fireplace and its options will completely heat your entire home.

Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.

It is recommended that in all cases, the fireplace be secured to the floor. Use the pallet packing brackets to accomplish this.

CARE OF GLASS, AND PLATED PARTS

If the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot fire will clean the glass. The most common reasons for dirty glass include: not using sufficient fuel to get the stove thoroughly hot, using green or wet wood, closing the draft so far that there is insufficient air for complete combustion. If it is necessary to clean

the glass, use a soft cloth with a non-abrasive cleaner.

Do not clean the glass when hot!

The glass is very strong but do not let burning fuel rest or fall against it and always close the door gently. Never force it shut!

If the glass should ever crack while the fire is burning, do not open the door until the fire is out and do not operate the stove again until the glass has been replaced with a new 5mm

thick piece of ceramic glass, available from your Napoleon / Wolf Steel Ltd. dealer. Do not substitute materials.

For information on glass removal and replacement, see Maintenance.

Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth.

W415-0594 / A / 02.15.07

7

HI-EFFICIENCY HEATING

A HOT AIR GRAVITY VENT SYSTEM (NZ221) may be

used to distribute heat to an adjoining room (located either above, or beside the room containing the fireplace) by way of vents. Air flow through this vent must be experimented with and the dampers of the grill adjusted manually to suit your requirements. This may take a few attempts; thereafter adjustments should no longer be required as is normally experienced with your central heating system registers.

The hot air vent must be installed in an upward direction! NEVER install in a downward direction. The hot air gravity vent system is not to be connected to a central heating system.

No more than two hot air gravity vents may be connected to the fireplace. Individual vent runs are not to exceed 10 feet.

All hot air gravity vents must be insulated.

INSTALLATION / FRAMING

51 1/2"

50 1/4"

43"

WARNING:

COMBUSTION AIR

ONLY

AVERTISSEMENT:

AIR COMBURANT

SEULEMENT

6 1/2"

4 3/8"

WARNING: BLOWER CONNECTION ONLY

AVERTISSEMENT: CONNEXION DE LA SOUFFLERIE SEULEMENT

19 3/8"

25 3/16"

30 3/4"

 

 

49 1/2"

 

 

24"

6 5/8"

 

 

 

8"

30 3/4"

10 3/4"

 

29 1/2"

 

 

27 1/2"

 

 

15"

 

24 3/4"

 

 

 

41"

 

 

48 5/8"

50" 87" 61 1/2"

30 3/4"

50"

21"

MIN

61 1/2"

When framing in unit,

allow for finishing material thickness.

"

1/

50

 

"

 

2

61

 

2 layers

of 1/2" cement board needed to fill gap A.

W415-0594 / A / 02.15.07

8

LOCATION AND CLEARANCES

The fireplace is shipped with a set-up face that is 1/8" larger on the top, bottom and each side than the faceplate. Leave the set-up face in place to act as a template when installing the finishing face.

Do not build shelves or cupboards into the area above the fireplace.

Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.

Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.

IMPORTANT

This unit, fully dressed, weighs 850 lbs (385.6kg)

Ensure there is adequate floor support for the unit, chimney and facing material. Some material could weigh thousands of pounds.

MAINTAIN THESE MINIMUM CLEARANCES TO

COMBUSTIBLES:

Framed enclosure

 

Rear

-

0" to stand-offs (rear)

Sides

-

6" to sides*

Ceiling

-

120" from the base of the unit

(enclosure)

 

(unless shielded with metal studs

 

 

and cement board).

Ceiling

-

84" from the base of the unit

(in front of fireplace)

Chimney

-

2" (follow manufacturers instructions)

 

-

1"

Hot Air Gravity Ductwork Insulation

This enclosure must provide greater clearance if air intake vents are run vertical along side the fireplace.

SOLID PACK CHIMNEY

Ceiling

- 120" from the base of the unit

(enclosure)

(unless shielded with metal studs

 

and cement board).

AIR COOLED

 

Ceiling

- 84" from the base of the unit

(enclosure)

 

We recommend that the fireplace be secured to the floor in all cases.

Using the door opening as a datum, level the fireplaceby shimming underneath the fireplace.

Remove and discard the lifting handles. Bend the tabs down and secure the unit to the floor.

The fireplace enclosure must be provided with sufficient air circulation to avoid a fire hazard. Install ventilation grilles (minimum openings of 40 sq. inches) at both floor and ceiling levels of the enclosure. These grilles must not restrict the flow of heat by more than 25%.

Do not install into any area having a height less than 7 feet (ceiling of enclosure to fireplace bottom, excluding hearth height).

The location of windows, doors and the traffic flow in the room where the stove is to be located should be considered. If possible, you should choose a location where the chimney will pass through the house without cutting a floor or roof joist.

W415-0594 / A / 02.15.07

9

WHEN USING A SOLID PACK CHIMNEY

The fireplace face and enclosure ceiling must be framed using 2x4 metal studs.

The minimum enclosure ceiling height is 7 feet. N o n - c o m b u s t i b l e materials (cement board and metal studs) must be used.

WHEN USING AN AIR COOLED CHIMNEY

W415-0594 / A / 02.15.07

10

OUTSIDE COMBUSTION AIR

Note: Incorporate a vertical loop or trap into air liners to reduce air flow when

unit is not in use.

Insulating the intake liners is recommended

in colder

climates to prevent condensation from occuring.

The Napoleon

Model NZ6000 takes outside air directly into the fireplace

through the openings in the left and right hand sides.

Decide on the most convenient location for the fresh air inlet ducts and

hoods which may be installed above or below floor level.

The fresh air inlet ducts and hoods must be installed.

Secure and seal the intake liners to the collars using 3 sheet metal screws, and high temperature sealant.

Vertical

Horizontal

rise is

run may be:

between:

 

6' & 10' max

5'

3' & 6'

15'

1' & 3'

20'

0' & 1'

25'

Included with the fireplace are:

- two 10' lengths of vent. Use a connector and seal if adding more length.

- two of intake hoods.

The vertical height of the air intake liner must not be greater than 2/3 the height of the chimney. If additional liner length is required, it may be doubled by increasing the size from 6" diameter to 8" diameter. Use a 6" to 8" increaser at the hood and a decreaser at the fireplace. Values in brackets represent 8" diameter intake liners.

The duct terminations must be located so they can not be blocked (i.e. snowdrifts). 4' above grade is recommended.

Make a 6 ½" inch hole to suit in an outside wall of the house. From outside, place the fresh air hood into the hole, open side down. Seal with caulking and secure.

MANTLE CLEARANCES

An optional combustible mantle must be a minimum of 12" above the top of the faceplate and not to extend more than 2" from the surface. See chart below for further information.

W415-0594 / A / 02.15.07

Loading...
+ 22 hidden pages