Planning your Installation
Heater Placement
Installation Options
Floor Protection Requirements
Safety Features
Outside Air
Mobile Home
12-13 GENERAL VENTING
Type of Vent
Installing Pellet Vent
Venting the Pellet Heater
Pellet Vent Termination
Alcove Installation (NPS40 Only)
Minimum Air Terminal Installations
14-17
NPS40 INSTALLATIONS
Minimum Clearance to Combustibles
Straight Installation
Corner Installation
Vertical Installation Examples
Horizontal Exhaust Through Wall Installation
Through wall with vertical rise and horizontal
termination installation
Minimum Inside vertical clearance
Class A Chimney Retrofi t
Hearth Mount Installation
17-22
NPI40 INSTALLATIONS
Minimum Clearance to Combustibles
Minimum Mantle Clearances
Rear or Top Vent Conversion Instructions
Installation Overview
Installation into a Masonry Fireplace
Prior to Installation
Installation into a masonry fi replace
Horizontal Vent Installation
Vertical Vent Installation
Installation into a Factory Built Fireplace
Framing (Built-in)
Prior to Installation
Installation into a masonry fi replace
Liner Installation
Installation into a combustible built in enclosure
Minimum framing dimensions
Minimum Enclosure Clearances
23
Flashing Installation
Trivet NPI40
Installing the viewing door NPS40 and NPI40
24
OPERATING INSTRUCTIONS
Start up
Shut down
Lighting heater manually
Proper pellet loading
25-28 GENERAL MAINTENANCE NPS40
AND NPI40
29 NORMAL OPERATING SOUNDS
30 WIRING DIAGRAM
31-35 REPLACEMENT PARTS
36-38 TROUBLE SHOOTING
39 MAINTENANCE LOG
40 NOTES
NPI40 FINISHING
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
Before installation, consult with the authority having jurisdiction (building department, fi re department etc...) to
determine if there is the need to obtain a permit.
W415-0616 / B / 02.18.08
NAPOLEON ® Pellet Heaters are manufactured under the strict Standard of the World Recognized
ISO 9001 : 2000 Quality Assurance Certifi cate.
NAPOLEON ® products are designed with superior components and materials, assembled by trained craftsmen
who take great pride in their work. The complete fi replace is thoroughly inspected by a qualifi ed technician before
packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON ®.
NAPOLEON PELLET HEATERS PRESIDENT'S LIFETIME LIMITED
WARRANTY
The following materials and workmanship in your new NAPOLEON® Pellet Heater are warranted against
defects for as long as you own the heater. This covers: the pellet hopper, outer shell, ceramic glass (thermal
breakage only) and ash drawer.
The combustion chamber and heat exchanger are warranted against defects for a period of fi ve years. All
other wearable parts and electrical components such as blowers, thermal switches and burn pot are covered and
Napoleon® will provide replacement parts free of charge during the fi rst year of the limited warranty.
Labour related to warranty repair is covered free of charge during the fi rst year. Repair work, however, requires
the prior approval of an authorized company offi cial. Labour costs to the account of NAPOLEON® are based
on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON®
dealer.
3
CONDITIONS AND LIMITATIONS
NAPOLEON® warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears
on the warranty registration card fi led with NAPOLEON® -- provided that the purchase was made through an authorized NAPOLEON® dealer and is subject to the following
conditions and limitations:
This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
The Pellet Heater must be installed by an authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with
the product and all local and national building and fi re codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect. Operating heater on high for extended periods
of time, is neglect. Parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and chemical cleaners nor chipping on porce-
lain enamel parts, nor any venting components used in the installation of the fi replace.
In the fi rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been
operated in accordance with the operation instructions and under normal conditions.
After the fi rst year, with respect to the President's Limited Lifetime Warranty, NAPOLEON® may, at its discretion, fully discharge all obligations with respect to this warranty by
refunding to the original warranted purchaser the wholesale price of any warranted but defective parts).
After the fi rst year, NAPOLEON® will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such
expenses are not covered by this warranty.
Notwithstanding any provisions contained in the President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defi ned as above and it shall not in
any event extend to any incidental, consequential or indirect damages.
This warranty defi nes the obligations and liability of NAPOLEON® with respect to the NAPOLEON® pellet heater and any other warranties expressed or implied with respect
to this product, its components or accessories are excluded.
NAPOLEON® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON® will not be
responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation,
excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust blowers, furnaces,
clothes dryers, etc.
Any damages to fi replace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation,
damaging chemicals or cleaners will not be the responsibility of NAPOLEON®.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty regis-
tration card must be returned within fourteen days to register the warranty.
Regular cleaning of the fi ne ash generated during the operation of this heater is a necessary part of maintaining your pellet heater. Failure of any components, which is at-
tributed to poor maintenance, is not warrantable and will not be covered by this policy.
NAPOLEON® reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGIS-
Thank you for purchasing the Napoleon® Pellet Heater.
This heater is designed for use with Pelletized Wood Only.
Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.
Keep this manual handy for future reference.
This Pellet Heater, when installed, must be electrically grounded in accordance with the local codes, or in the absence of local codes, use
the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National Electrical Code in the United States.
This heater will not operate using natural draft or without a power source for the blower systems and fuel feed system.
PELLET QUALITY
Pellet quality is important, please read the following:
Your Napoleon® Pellet Heater has been designed to burn premium hard or soft wood pellets only. Do not use any other type of
fuel such as fi re logs or fi re starting pellet, as this will void the warranties stated in this manual.
The performance and heat output of the pellet heater is directly related to the quality and moisture of the pellets.
Store pellets in a cool dry area to prevent moisture absorption.
CAUTION: It is important to select and use only pellets that are dry and free of dirt or any impurities such as high salt content. Dirty fuel
will adversely affect the operation and performance of the unit and will void the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet manufacturers. We recommend the use of pellets that meet or exceed these standards. Ask your dealer
for a recommended pellet type.
P.F.I. PELLET STANDARDS:
Fines (fi ne particles)1% maximum through a 1/8" screen
Bulk Density40 pound per cubic foot minimum
Size1/4" to 5/16" diameter, 1/2" - 1 1/2" long maximum
Ash Content1% maximum (Premium grade)
3% maximum (Standard grade)
Moisture Content8% maximum
Heat ContentApproximately 8200 BTU per pound minimum
If the fuel does not comply to this standard the unit may not operate as designed.
We recommend the use of premium grade (1% ash content) for longer stove life and less frequent cleaning.
SPECIFICATIONS
Approximate Maximum Heating Capacity (in square feet)* 800 to 2000 Sq. Feet
* Heating capacity will vary depending on the home's fl oor plan, degree of insulation, and the outside temperature. It is also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on
fuel quality may occur.
HEATING SPECIFICATIONS
(NPS40), 45 Hours (NPI40)
W415-0616 / B / 02.18.08
DIMENSIONS
7
Figures 1a-b
Figures 2a-c
NPS40
NPI40 with NI800 Flashing Shown
W415-0616 / B / 02.18.08
8
Figures 3a-c
DIMENSIONS CONTINUED
NPI40 with AK9 Adapter and CISK Flashing Shown
W415-0616 / B / 02.18.08
Figures 4a-c
9
DIMENSIONS CONTINUED
NPI40 with AK8 Adapter and GICSK Flashing Shown
W415-0616 / B / 02.18.08
10
Electrical Rating115 Volts, 3.6 Amps, 60Hz
Watts During Start-Up Sequence
Watts During Operation180 (approximately)
NPS40 Width22 3/8"
NPS40 Height30 1/2"
NPS40 Depth26 5/8"
Weight210 Pounds
Exhaust Collar3"
Intake Collar2"
NPS40 Hopper Cap.55 Pounds
NPI40 Hopper Cap.45 Pounds
EPAExempt
Burn Rate**1.0 to 5.0 (Pounds Per Hour)
BTU/h**8500 to 42500
Minimum Fireplace Opening
Size
* In order to install fl ashing fl ush to fi nished wall and centered
within the opening the front opening of the fi replace or enclosure
must be 32 5/8" wide.
SPECIFICATIONSEPA COMPLIANCE
400 (approximately)
Front: 22 1/2* W x 20 5/8 H x
14 1/4 D
Back: 20 3/8 W
This heater is EPA exempt from Phase II requirements, but has
been tested for emissions using EPA test methods by Warnock
Hersey.
GENERAL INSTALLATION
PLANNING YOUR INSTALLATION
!
WARNING
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO
FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
Check with local building offi cials for any permits required for
installation of this pellet heater and notify your insurance company
before proceeding with installation.
Before installing we recommend placing the heater outside and
load 5 pounds of pellets inside the hopper. Plug the heater in and
let it run on HIGH until the pellets run out. This will cure the paint
and burn off the oils on the steel, there by minimizing any smell
inside the home.
HEATER PLACEMENT
Have an authorized Napoleon® dealer install the heater. If you
install the heater yourself, have your dealer review your installation
plans and/or installation.
Draw out a detailed plan of the installation including dimensions
and verify the dimensions with the requirements listed in this
manual.
For built-in enclosures, when determining the location of the
heater, locate the wall studs (for horizontal penetrations). You may
wish to adjust the heater position slightly to ensure the vent does
not intersect with a framing member.
Heater must be positioned so that no combustibles are within, or
can swing within (e.g. drapes, doors), 48" of the front of the heater.
If the heater is placed in a location where the ceiling height is less
than 7' above the base of the heater, the installation must follow
the requirements in the section "Alcove Installations Requirements"
W415-0616 / B / 02.18.08
NPS40:
To install in a Residential or Mobile Home see the section "Mobile
Home Requirements".
For alcove installations see the section "Alcove Installation
Requirements".
For horizontal vent or vertical vent see the section "General Venting".
See the section "Outside Air" for this option.
NPI40:
The insert can be adapted to vent out the rear or vertically.
To install as an insert into an existing masonry fi replace factory
built fi replace or a built in combustible enclosure see Insert Installation.
FLOOR PROTECTION REQUIREMENTS
NPS40:
The heater must be installed on a non-combustible fl oor protector
extending the full depth of the heater and extending a minimum 6"
in front and on either side (minimum .018" thick - 26 gauge).
The fl oor protector must extend under and 2" beyond each side
and rear of a "Tee" (if used).
NPI40:
In the case of the NPI40, the fl oor protector must have a R-value
of 0.4 hr ft²°F
BTU
INSTALLATION OPTIONS
11
SAFETY FEATURES
HIGH LIMIT SWITCH:
Your heater is equipped with a high limit switch. In the event that
the temperature of the heater approaches an unsafe operating
temperature, this switch will shut down the pellet feed, which will
eventually shut down the unit. If this happens, it is important to fi nd
out why the unit overheated. Contact your local dealer.
LOW LIMIT SWITCH:
This switch will automatically shut down the heater if the fi re goes
out.
BLOWER OVER-RIDE SWITCH:
Your heater is equipped with a convection blower that circulates
hot air into your room. This switch will automatically turn the blower
on, when the temperature at the back of the fi re box reaches a certain temperature. The blower can cycle from your desired setting
to maximum speed depending on the feed rate. When the heater
cools back down, the blower will return to the initial setting.
VACUUM SWITCH:
This switch will sense lack of air fl ow through the heater and
shut down the pellet feed. This lack of fl ow could be caused by a
blocked vent.
POWER FAILURE:
In the event of a power failure, the heater will shut down. Once
power is restored, the heater will re-start, unless the convection
air temperature has gone above the high limit switch setting. If this
happens, contact your local dealer.
The heater must be grounded to
the steel chassis of the mobile
home (Some states do not require
this; check with your local building
department).
WARNING: DO NOT INSTALL IN
A SLEEPING ROOM.
CAUTION: THE STRUCTURAL
INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,
AND CEILING ROOF MUST BE
MAINTAINED.
Figure 5
OUTSIDE AIR
Available from your Napoleon Dealer (114KT)
Outside air must not be drawn from an enclosed space (garage,
unventilated crawl space).
NOTE: Napoleon® strongly suggests using outside air for all residential installations, especially for those that are energy effi cient,
air-tight homes.
Outside air supply must not be over 15' long.
Outside air vents must be made with 1 3/4" diameter or larger
metal or aluminum duct with a metal screen attached to the end to
keep out rodents (P.V.C. or other materials may not be used).
The outside air inlet must not be above or within 12" of the chimney termination, must have a rain cap or down-turned elbow to
prevent the water from entering and be located so that it will not
become plugged by snow or other material.
Outside air is mandatory for a combustible built-in enclosure install
for the NPI40.
MOBILE HOME
Installation into a manufactured home or mobile home should be
installed in accordance with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United
States or the Mobile Home Standard, CAN/CSA Z240 MH Series,
in Canada.
W415-0616 / B / 02.18.08
12
GENERAL VENTING
PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE
TO ANY COMBUSTIBLE (install vent at clearances specifi ed by
the vent manufacturer).
DO NOT CONNECT THE PELLET VENT TO A VENT OR CHIMNEY SERVING ANY OTHER APPLIANCE OR HEATER.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
TYPE OF VENT
Must be an approved 3" or 4" Diameter Type "L" or "PL" vent,
vented to the outside or connect the vent to a factory built type "A"
chimney using an adaptor; and/or stainless steel chimney liner for
masonry fi replace installations. Use 4" diameter vent if vent or liner
height is over 15' or if installation is over 4,000' above sea level.
INSTALLING THE PELLET VENT
The vent must have a support bracket every 5' when on the exterior wall.
To achieve optimum performance, keep vent runs as short as possible, especially on horizontal installations.
MAXIMUM VENTING:
Maximum venting height is 33'. Maximum horizontal offset is 10'.
Use no more than 180° of elbows (two 90' elbows, or two 45'
elbows and one 90' elbow, etc), plus termination.
VENT INSTALLATION:
Termination must exhaust above the air inlet elevation, and parallel
or above the exhaust output of the pellet appliance. It is recommended that at least 3' of vertical pipe be installed to create some
natural draft. This is to help prevent the possibility of smoke or
odour during the appliance shut down or in the event of a power
outage.
Horizontal sections must
have a 1/4" rise every 12"
of travel if longer than 3'.
VENTING THE PELLET HEATER
Use an approved wall thimble when passing the vent through
walls and a ceiling support/fi re stop spacer when passing the vent
through ceilings (maintain a 3" clearance to any combustibles).
PELLET VENT TERMINATION
The vent termination must have an approved cap (to prevent water
from entering) or a 45° downturn.
If the termination is located on a windy side of the house, a shield
is recommended to prevent soot from building up on the side of the
house.
Horizontal terminations must protrude 12" from the wall, vertical
terminations require a minimum 24" above the highest point that it
penetrates through the roof.
Depending on pellet quality, vent confi guration and air settings,
black soot may occur on the terminal wall.
ALCOVE INSTALLATION (NPS40 ONLY)
The pellet vent connections must be sealed with
HI-Temp RTV Silicone and
screwed together with at
least 3 3/8" long stainless
steel screws. Seal each
vent section by injecting
a liberal amount of 500°F
(260°C) RTV silicone
sealant into the gap. We
recommend sealing the
outside of the vent connections to permit easier
access when
servicing.
Figure 6
Figure 7
Minimum Alcove Dimensions
W415-0616 / B / 02.18.08