3.1.1 INSTALLING LOG SET INTO EXISTING FIREPLACE 8
3.1.2 INSTALLING LOG SET INTO MANTEL 9
3.2 HARD WIRING INSTALLATION 10
3.3 SECURING THE LOG SET 11
4.0 OPERATING INSTRUCTIONS 12
4.1 OPERATING CONTROL PANEL 12
4.2 OPERATING BY REMOTE CONTROL 13
4.3 REMOTE BATTERY INSTALLATION 13
5.0 FINISHING 14
5.1 NEFI24H LOG PLACEMENT 14
5.2 NEFI27H LOG PLACEMENT 14
5.3 EMBER BED PLACEMENT 15
5.4 CHARCOAL EMBER PLACEMENT 16
6.0 WIRING DIAGRAM 17
7.0 REPLACEMENT PARTS 18
7.1 NEFI24H OVERVIEW 19
7.2 NEFI27H OVERVIEW 20
8.0 TROUBLESHOOTING 21
9.0 WARRANTY 22
10.0 NOTES 23
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
W415-1461 / C / 08.04.16
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your municipality
for recycling instructions.
1.0 INTRODUCTION
!
WARNING
• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF
CONTACTED.
• Do not operate appliance before reading and understanding operating instructions. Failure to operate
appliance according to operating instructions could cause fi re or injury.
• Risk of burns. Power to the appliance should be turned off and the appliance allowed to cool before
servicing. To disconnect power to the appliance, turn controls to off, then remove plug from outlet.
• Do not install damaged, incomplete or substitute components.
• Do not burn wood or other materials in this appliance.
• Young children should be carefully supervised when they are in the same room as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier
is recommended if there are at risk individuals in the house. To restrict access to an appliance or stove,
install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the
room and away from hot surfaces.
• Clothing or other fl ammable material should not be placed on or near the appliance.
• Due to high temperatures, the appliance should be located out of traffi c and away from furniture and
draperies.
• Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot
surfaces.
• Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
• Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
from hot surfaces. These screens and guards must be fastened to the fl oor.
• Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
• It is imperative that the control compartments, circulating blower and its passageway in the appliance
and are kept clean. The appliance should be inspected before use and at least annually by a qualifi ed
service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding
material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and
other fl ammable vapors and liquids.
• Under no circumstances should this appliance be modifi ed.
• Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician
to inspect the appliance and to replace any part of the control system which has been under water.
• Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the
glass should be done by a licensed or qualifi ed service person.
• Do not strike or slam shut the appliance glass door.
• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As
with all plastic bags, these are not toys and should be kept away from children and infants.
• Servicing should be done only while the appliance is disconnected from the power supply circuit.
• Always unplug appliance when not in use.
• Do not operate this appliance with a damaged cord or plug after the appliance malfunctions, has been
dropped or damaged in any manner. Return appliance to authorized service facility for examination,
electrical or mechanical adjustment, or repair.
• Do not use outdoors.
• Never locate appliance where it may fall into a bathtub or other water container.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord
away from traffi c area and where it will not be tripped over.
• Connect to properly grounded outlets only.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an
electric shock or fi re, or damage the appliance.
• To prevent a possible fi re, do not block air intakes or exhaust in any manner. Do not use on soft
surfaces, like a carpet, where openings may become blocked.
• Always plug appliances directly into a wall outlet/receptacle. Never use an extension cord or
relocatable power tap (outlet/power strip).
• Ensure clearances to combustibles are maintained when building a mantel or shelves above the
appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting,
discolouration or damage to decorations, a T.V. or other electronic components.
3.7C
3
EN
W415-1461 / C / 08.04.16
EN
4
1.1 DIMENSIONS
NEFI24H ILLUSTRATED
FRONT VIEWSIDE VIEW
24"
610mm
14"
356mm
356mm
14"
27"
686mm
NEFI27H ILLUSTRATED
15 1/2"
393mm
14"
356mm
W415-1461 / C / 08.04.16
A.
B.
C.
D.
E.
This electric appliance meets the construction and safety standards of H.U.D. for application in manufactured
homes when installed according to these instructions.
!
WARNING
1.2 LISTING APPROVALS
This log set has been tested in accordance with the
CSA Standards for fixed and location-dedicated electric
room appliances in the United States and Canada. If
you need assistance during installation, please contact
your local dealer.
NOTE: This log set must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition in the United States or
the Canadian Electric Code, CSA C22.1 in Canada.
1.3 GENERAL INSTRUCTIONS
Model Number
Description
Voltage
Watts
Amps
Appliance Width
Appliance Height
Appliance Depth
Net Weight
Gross Weight
5
NEFI24HNEFI27H
24" Electric
Logset Insert
120V AC120V AC
Max 1500WMax 1500W
15 AMP Grounded
Circuit
24" (610mm)27" (686mm)
14"
(356mm)
14" (356mm)14" (356mm)
25.4lbs (11.5kg)29.5lbs (13.4kg)
35.3lbs (16kg)40.3lbs (18.3kg)
27" Electric
Logset Insert
15 AMP Grounded Circuit
15 1/2" (393mm)
EN
READ THESE INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION. FAILURE TO
FOLLOW THEM COULD CAUSE AN APPLIANCE MALFUNCTION RESULTING IN SERIOUS INJURY
AND/OR PROPERTY DAMAGE.
ALL ELECTRIC APPLIANCES HAVE HOT AND ARCING OR SPARKING PARTS INSIDE. DO NOT USE
IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE PRESENT.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE OPTIONAL
ACCESSORIES LISTED IN THESE INSTRUCTIONS. USE OF OPTIONAL ACCESSORIES NOT
SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE WARRANTY AND/OR
RESULT IN A SAFETY HAZARD.
DO NOT OPEN. RISK OF ELECTRIC SHOCK. NO USER-SERVICEABLE PARTS INSIDE.
DO NOT USE DAMAGED ELECTRICAL CORDS.
SERVICING SHOULD BE DONE ONLY WHILE THE APPLIANCE IS DISCONNECTED FROM THE
POWER SUPPLY CIRCUIT.
TO PREVENT ELECTRIC SHOCK MATCH THE WIDE BLADE OF PLUG TO WIDE SLOT OF
RECEPTACLE AND FULLY INSERT.
Prior to plugging your appliance into an electrical outlet, verify that the house circuit breakers for the
outlet are on.
The appliance may emit a slight, harmless odour when fi rst used. This odour is normal and it is caused
by the initial heating of internal appliance elements and will not occur again.
If your appliance does not emit heat, consult the operation section of this manual for further
information.
Use with a CSA- or UL-certifi ed surge protector.
Do not route the power cord directly underneath the appliance.
4.8B
As with most electronic devices, your new log set has been designed to operate at temperatures between
5°C (41°F) and 35° C (95°F). During the colder winter months, allow the log set to reach room temperature
before turning it on.
W415-1461 / C / 08.04.16
6
SAMPLE
1.4 RATING PLATE INFORMATION
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARD: CSA 22.2 NO. 46 AND UL 1278 /
EN
HOMOLOGUÉ SELON LES NORMES NATIONALES CANADIENNES ET AMÉRICAINES:CSA 22.2 NO. 46 UL 1278
ELECTRIC FIREPLACE. SUITABLE FOR
BEDROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE
HOME INSTALLATION.
FOYER À ÉLECTRIQUE. HOMOLOGUE POUR
INSTALLATION DANS UNE CHAMBRE A
COUCHER, UNE SALLE DE BAIN ET UN STUDIO.
APPROPRIE POUR INSTALLATION DANS UNE
MAISON MOBILE.
MASTER CONTRACT: 161746
FREQUENCY: 60Hz FRÉQUENCE: 60Hz
POWER: 1500W PUISSANCE: 1500W
DATE CODE: XXXXX CODE DE DATE:DESIGNED IN NORTH AMERCIA
BY WOLF STEEL LTD.
WOLF STEEL LTD.
24 NAPOLEON ROAD,
BARRIE, ON, L4M 0G8 CANADA
MADE IN CHINA
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model of the appliance.
For rating plate location, see “LABEL LOCATION” section.
This illustration is for reference only. Refer to the rating plate on the log set for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
NOTE: Do not use the log set during mobile home transportation.
1.5 LABEL LOCATION
"DO NOT COVER"
LABEL (W385-1946)
MODEL / MODÈLE:
VOLTAGE: 120 VAC TENSION: 120VCA
FABRIQUE EN CHINE
SERIAL NUMBER/NO. DE SERIE:
CONTRAT-CADRE: 161746
NEFI24H
DESIGN AMERIQUE DE NORD
PAR WOLF STEEL LTD.
NEFI24
ATTENTION
LABEL
(W385-2133)
WARNING
LABEL
(W385-1943)
W385-2026 / A
W415-1461 / C / 08.04.16
LEFT SIDE
FRONT
RATING PLATE WITH
SERIAL NUMBER
NEFI24H (W385-2026)
NEFI27H (W385-2066)
WARNING LABEL
(W385-1944)
CAUTION LABEL
(W385-1945)
RIGHT SIDE
!
WARNING
2.0 LOCATING LOG SET
This appliance is for use on 120 volts. The cord has a plug
as shown in (A). An adapter as shown in (C) is available for
connecting three-blade grounding type plugs to two-slot
receptacles. The green grounding plug extending from the
adapter must be connected to a permanent ground such as
a properly grounded outlet box. The adapter should not be
used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove
plug from outlet.
DUE TO HIGH TEMPERATURES, THIS ELECTRIC APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC. KEEP COMBUSTIBLE MATERIALS SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS,
CLOTHES AND CURTAINS AT LEAST 36" FROM THE FRONT OF THE APPLIANCE.
NEVER LOCATE THIS ELECTRIC APPLIANCE WHERE IT MAY FALL INTO A BATHTUB OR OTHER
WATER CONTAINER.
WEAR SAFETY GLOVES AND SAFETY GLASSES FOR PROTECTION DURING INSTALLATION AND
MAINTENANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE ELECTRIC APPLIANCE
MUST NOT BE INSTALLED AGAINST VAPOR BARRIER OR EXPOSED INSULATION. LOCALIZED
OVERHEATING COULD OCCUR AND A FIRE COULD RESULT.
DO NOT EXPOSE THE ELECTRIC APPLIANCE TO THE ELEMENTS (SUCH AS RAIN, ETC.)
2.1 UNPACKING AND TESTING LOG SET
Carefully remove the appliance from the box and remove the support brackets. Prior to installing the
appliance, remove all packaging material and test to make sure the appliance operates properly by plugging
the power supply cord into a conveniently located 120V, 15 Amp minimum grounded outlet.
7
EN
2.2 GROUNDING LOG SET
NOTE: Must be connected to a dedicated 15 amp circuit.
The use of an extension cord is NOT permitted.
GROUNDING METHODS
METAL SCREW
(A)
COVER OF
GROUNDED
OUTLET BOX
GROUNDING PIN
(C)
GROUNDING
(B)
ADAPTER
MEANS
NOT ALLOWED IN CANADA
96.1
W415-1461 / C / 08.04.16
8
!
WARNING
68.5A
3.0 INSTALLATION
EN
RISK OF FIRE! THE POWER CORD MUST NOT BE PINCHED AGAINST A SHARP EDGE. SECURE CORD TO AVOID
TRIPPING OR SNAGGING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY. DO NOT RUN
CORD UNDER CARPETING. DO NOT COVER CORD WITH THROW RUGS, RUNNERS OR THE LIKE. ARRANGE CORD
RISK OF FIRE! TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKE OR EXHAUST IN ANY MANNER. DO NOT
RISK OF FIRE! DO NOT BLOW OR PLACE INSULATION AGAINST THE APPLIANCE.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES.
USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER
THIS APPLIANCE IS HEAVY. IT IS HIGHLY RECOMMENDED THAT TWO PEOPLE INSTALL THIS APPLIANCE.
HEATER VENTS ON THE ELECTRIC APPLIANCE CANNOT, IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE
DO NOT RUN THE POWER CORD HORIZONTALLY, DIRECTLY BELOW THE APPLIANCE.
NOTE: Follow all National and local electrical codes.
3.1 LOG SET INSTALLATION
The log set can be installed in any location. It is suggested to install the log set into an existing fireplace or a
wood mantel for aesthetic purposes.
AWAY FROM TRAFFIC AREAS AND WHERE IT WILL NOT BE TRIPPED OVER.
USE ON SOFT SURFACES WHERE OPENINGS MAY BECOME BLOCKED.
WARRANTY AND/OR RESULT IN A SAFETY HAZARD.
FLAMMABLE VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
HAZARD.
Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high
traffic areas.
3.1.1 INSTALLING LOG SET INTO EXISTING FIREPLACE
The log set insert must be installed in an opening with the minimum cavity sizes shown below:
MINIMUM FIREPLACE CAVITY SIZE
HEIGHT WIDTHDEPTH
LOG SETABC
NEFI24H15"
(381mm)
NEFI27H16"
(406mm)
NOTE: Seal all chimney drafts with non-combustible materials to prevent any chimney debris from
falling onto the log set. Cap the top of the chimney flue to prevent rain from entering.
Plug the log set into an outlet which has a 15Amp, 120V rating. If it is necessary to hard wire the log set see
"HARD WIRING INSTALLATION" section.
WARNING: Due to the high temperatures, do not use existing fireplace doors which close or seal off
the log set. If installed behind any fireplace door, allow heat to be exhausted. If using existing screens,
the screen must provide adequate airflow in front of the log set.
24"
(610mm)
27 1/2"
(698mm)
14"
(356mm)
14"
(356mm)
Do not install the log set
into a cavity smaller than
that referenced in the
table.
A
B
C
W415-1461 / C / 08.04.16
3.1.2 INSTALLING LOG SET INTO MANTEL
MANTEL
!
MANTEL
STEP 1: LIFT
STEP 2: INSERT
STEP 3:
SET APPLIANCE
!
!
NOTE: To prevent damaging the base of the mantel, carefully lift the log set into the mantel while
avoiding contact with the front edge of the mantel base.
A.With two people, lift the log set up and insert into the opening. Do not push or slide the bottom of the
log set on the floor base, see Figure 1.
B.Set the log set down and into place, see Figure 2.
9
EN
Fig. 1
NE GLISSEZ PASL'APPAREIL
DO NOT SLIDE LOGSET
Fig. 2
MANTEL
STEP 2: INSERT
STEP 1: LIFT
W415-1461 / C / 08.04.16
10
GREEN
BLACK
WHITE
3.2 HARD WIRING INSTALLATION
EN
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
HARD WIRING CONNECTION
If it is necessary to hard wire, a qualified electrician must remove the cord connection, and wire directly to the
household wiring. The wire and power supply breaker must be rated for 120V and a minimum of 15 Amps.
This log set must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
NOTE: There are 3 wires from the fireplace junction; white (neutral), black (power L1) and green
(ground) that connect to 120V power supply (breaker panel), see below.
!
WARNING
NOTE: It is recommended to
secure the log set after hard
wiring, refer to "SECURING
THE LOG SET" section.
White, Green and
Black wires:
Connect to 120V
power supply.
A. Remove the securing screw from the electrical cover plate, located on the rear of the log set.
B. Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole.
C. Separate the black, white and green wires that have the wire nuts on them.
D. Remove the wire nuts and secure the black wire (power L1) to the black (power L1) lead of the
power supply. Connect the white wire from the unit to the white (neutral) wire from the power
supply. Connect the green wire to the ground wire.
E.Resecure the cover plate.
FIREPLACE
JUNCTION
BLACK
WHITE
GREEN
(L1)
(N)
(G)
WIRE NUT
BLACK
WHITE
GREEN
SUPPLY
POWER
W415-1461 / C / 08.04.16
NOTE: Leave enough
wire so that the log
set can be removed
from the enclosure
without disconnecting
the power supply.
3.3 SECURING THE LOG SET
NOTE: It is recommended to secure the log set especially if hard wiring the log set.
11
A.Place the log set in a position which provides optimum flame performance. NOTE: To achieve flame
effect, the log set should be set 1" away from the rear wall.
B. Secure in place using 2 screws (not supplied).
EN
W415-1461 / C / 08.04.16
POWER
Turns the appliance ON/OFF.
FLAME & EMBER LIGHTCONTROL
HEATER CONTROL
TIMER
TEMPERATURECONTROL
Controls Flame brightness and the Ember Light.
5 Settings
: Flame & Ember off (FO), Ember on but Flame off (LL), small Flame & Ember (F1), medium Flame & Ember (F2), brightest Flame and Ember (F3).Default setting is (F3).
Turns the Heater and Blower ON/OFF.
4 Settings: Heater & Blower off (HO), Blower on (BL), lowheat (H1), high heat (H2). Default setting is (HO).
Timer can be programed to run appliance for specific lengths of time (30mins. minimum to 6hrs maximum).Default setting is Timer de-select.
Press and hold the Timer button for 5 seconds. Thiswill change the button to Temperature Control, or viceversa. There are 7 temperature settings (61
°F, 64°F, 70°
F,
75
°F, 81°F, 85°F and OFF).
Default setting is de-select Temperature Control.
F° / C° SWITCH
Hold 5
seconds
To change temperature format, Fahrenheit or Celsius.Press and hold the Flame button for 5 seconds.Default setting is Fahrenheit.
HEATER LOCK
Hold 5
seconds
Heater button can be locked or unlocked by holding theHeater button for 5 seconds.Default setting is heater unlock
Hold 5
seconds
12
4.0 OPERATING INSTRUCTIONS
Once the log set has been plugged into a grounded electrical outlet or hard wired to a dedicated 120V power
EN
supply, it is ready to operate.
ATTENTION: Ensure the house circuit breakers for the power supply are turned on. When initially
connecting the appliance into a power source the unit will perfom an LED check. The unit will flash
on and off for 5 seconds.
4.1 OPERATING CONTROL PANEL
The Control Panel is located on the front of the log set.
W415-1461 / C / 08.04.16
4.2 OPERATING BY REMOTE CONTROL
WARNING
!
TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND
CHILDREN. DO NOT USE IN CRIBS, BED, CARRIAGES OR PLAY PENS. THIS BAG IS NOT A TOY.
KNOT BEFORE THROWING AWAY.
NOTE: When operating the remote control, it must be directed towards the front center of the log set.
A.The power button can be used to turn the log set on/off. Pressing
this button activates the power to the log set. Pressing the
power button again will turn off the log set. The ember and log will
fade after 4 seconds after turning off the log set.
B.To adjust the flame brightness and ember log light, press the flame
button . There is one ember log light and three flame brightness
levels to cycle through and then an off setting (LL, F1, F2, F3 and
then F0). F3 is the brightest flame level, LL is the ember log light
only.
C.To control the thermostat function press the thermostat button .
There are 7 temperature settings (61°F, 64°F, 70°F, 75°F, 81°F 85°F
and off). The default setting will display Fahrenheit. Press the
thermostat button to cycle through the settings. Once you have
selected the desired temperature the heater will automatically
operate until that temperature is reached. When the room
temperature is 2 degrees lower than the temperature setting, the
heater will turn on.
13
EN
D.To activate the heater and blower, press the heater button , the
blower will turn on. Press the heater button again to set desired low
or high heat temperature; press the heater button again to turn off
the heater.
E.The timer controls all operating modes of the log set. To activate the
timer, press the timer button , the icon will illuminate and the time
will appear on the LED display. To choose the desired time, continue to press the timer button, there
are 8 settings (30mins,1h, 2h, 3h, 4h, 5h, 6h and off). The fireplace will turn off at the setting time.
F.To turn off the log set, press the power button once on the remote, or press the power button once on
the control panel on the unit.
NOTE: This hand held remote control must remain within 6 meters or 19 feet of the log set to be
effective.
4.3 REMOTE BATTERY INSTALLATION
1. To replace the existing battery, remote the battery
holder.
2. To remove the battery holder, turn remote onto
front side and press the left side lever towards the
center while pulling the battery holder out using the
slot provided.
3. Replace existing battery, type CR 2025, with a
new battery and reinstall the battery holder into the
remote by sliding it into position, as shown.
4. Battery cover is secure onto the remote control
when a "CLICKING" noise is heard.
REMOTE
(REAR SIDE)
BATTERY (CR 2025)
BATTERY COVER
W415-1461 / C / 08.04.16
14
!
WARNING
5.0 FINISHING
EN
5.1 NEFI24H LOG PLACEMENT
1
POWER SUPPLY SERVICE MUST BE COMPLETED PRIOR TO FINISHING TO AVOID
RECONSTRUCTION.
HEAT VENTS AND AIR OPENINGS CANNOT BE COVERED IN ANY CIRCUMSTANCES.
PIN
2
#1
Place the log (#1) onto the pin.
Ensure the log is secure onto the
pin, as shown.
Place the logs shown on the location
dimples on the burner platform.
3
Place log (#2) onto the pin. Ensure
the log is secure onto the pin, as
shown.
#2
5.2 NEFI27H LOG PLACEMENT
12
PIN
PIN
#1
Place the logs shown on the location
W415-1461 / C / 08.04.16
dimples on the burner platform.
Place log (#1) onto the pin. Ensure the log
is secure onto the pin, as shown.
34
PIN
15
EN
Place log (#2) onto the pin. Ensure the log
is secure onto the pin, as shown.
5.3 EMBER BED PLACEMENT
#2
#3
Place log (#3) onto the pin. Ensure the log
is secure onto the pin, as shown.
Place the ember bed over the LED tray, as
shown.
W415-1461 / C / 08.04.16
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.