CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
EN
OPERATING INSTRUCTIONS
MODEL 2300 MEETS THE 2015 U.S ENVIRONMENTAL PROTECTION AGENCY (E.P.A) CRIB WOOD EMISSION LIMIT FOR WOOD STOVES SOLD AFTER MAY 15,
2015, 40 C.F. R. PART 60. THIS STOVE HAS BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482.
2300
PEDESTAL MODEL
SAFETY INFORMATION
WARNING
!
If the information in these instructions is not followed exactly ,
a fi re or explosion may result causing property damage,
personal injury or death. Improper installation, adjustment,
alteration, service or maintenance can cause injury or
property damage, bodily injury or even death. Please read
entire manual before you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. Do not install an unvented gas log set into the appliance.
FR
PG
37
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too
close can catch fi re.
- Children and pets must be kept from touching the appliance when it is
hot.
- The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi re authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- At least 14 square inches (90.3 square centimeters) of outside air must
be admitted to the room or directly to the unit through a 4” (101.6mm)
diameter pipe.
- This appliance is designed to burn natural wood only. Higher effi ciencies
and lower emissions generally result when burning air dried seasoned
hardwoods, as compared to softwoods or to green or freshly cut
hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine oil,
etc.
- Do not burn trash or garbage, lawn clippings / waste, rubber, waste
petroleum products, paints or paint thinners / solvents, plastic, materials
containing asbestos, construction debris, railroad ties or treated wood,
manure or animal remains, salt water driftwood or salted materials,
unseasoned wood, coal, charcoal, coloured paper, cardboard, plywood or
particleboard.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts
to achieve heat output rates that exceed design specifi cations can result
in steel distortion and damage.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
NOTE: The camera icon indicates video tutorials are available as additional reference, visit
http://mynapoleon.napoleonproducts.com/download/index/44/1
1.0 INSTALLATION OVERVIEW 3
2.0 INTRODUCTION 4
2.1 DIMENSIONS 5
2.2 SPECIFICATIONS 5
2.3 GENERAL INSTRUCTIONS 6
2.4 GENERAL INFORMATION 7
2.5 RATING PLATE INFORMATION 8
3.0 PRE-INSTALLATION PREPARATION 9
3.1 APPLIANCE PLACEMENT 9
3.2 CLEARANCE TO COMBUSTIBLES 9
3.3 FLOOR PROTECTION 10
3.4 OUTSIDE AIR 10
4.0 INSTALLATION 11
4.1 CHIMNEY 12
4.1.1 CHIMNEY CONNECTION 13
4.1.2 ADDING SECTIONS 14
4.1.3 TYPICAL THROUGH THE CEILING 15
4.1.4 TYPICAL THROUGH THE WALL 16
4.1.5 TYPICAL EXISTING MASONRY 16
5.0 FINISHING 17
5.1 DOOR REMOVAL / INSTALLATION 17
5.2 DOOR HANDLE INSTALLATION 17
5.3 BRICKS AND BAFFLE INSTALLATION 18
6.0 OPTIONAL KIT INSTALLATIONS 19
6.1 BLOWER KIT INSTALLATION 19
6.1.1 BLOWER INSTALLATION 19
7.0 OPERATION 20
7.1 OPTIMUM BURN METHOD 21
7.2 AIR CONTROL 22
7.3 FIRE EXTINGUISHERS / SMOKE & CARBON MONOXIDE DETECTORS 22
7.4 FUEL 23
7.5 LIGHTING A FIRE 23
7.5.1 FLASH FIRE 23
7.5.2 EXTENDED FIRE 24
7.6 SMOKING 24
8.0 MAINTENANCE 24
8.1 ASH REMOVAL PROCEDURES 25
8.2 CREOSOTE FORMATION AND REMOVAL 25
8.3 RUNAWAY OR CHIMNEY FIRE 26
8.4 CHIMNEY CLEANING 26
8.5 GLASS REPLACEMENT 27
8.6 GASKET REPLACEMENT 27
8.7 SECONDARY AIR MANIFOLD REPLACEMENT 28
8.8 CARE OF GLASS 29
8.9 CARE OF PLATED PARTS 29
8.10 WOOD 30
9.0 REPLACEMENTS 31
9.1 OVERVIEW 32
10.0 TROUBLESHOOTING 33
11.0 WARRANTY 34
11.0 SERVICE HISTORY 35
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
W415-1473 / A / 09.30.16
1.0 INSTALLATION OVERVIEW
3
Draft, see “AIR CONTROL”
section.
Door, see “DOOR
REMOVAL /
INSTALLATION”
section.
Brick and Baffles, see
“BRICK AND BAFFLES
INSTALLATION” section.
EN
Rating plate, see
“RATING PLATE
INFORMATION”
section.
Blower, see
“OPTIONAL BLOWER
INSTALLATION”
section.
Handle, see “DOOR
HANDLE INSTALLATION”
section.
Ash Drawer, see “ASH REMOVAL
PROCEDURES" section of the manual as
well as the optional ash drawer kit EP20LAD
for the leg model and optional ash pan kit
EP20PAD for the pedestal model.
Outside air, see “OUTSIDE AIR”
section.
W415-1473 / A / 09.30.16
4
2.0 INTRODUCTION
EN
!
WARNING
• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
• ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND
IS PROHIBITED.
• Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance
according to operating instructions could cause fi re or injury.
• Before installing this appliance, contact the local building or fi re authority and follow their guidelines.
• This appliance must be installed by a qualifi ed installer.
• Risk of burns. The appliance should be turned off and cooled before servicing.
• Do not operate without fully assembling all components.
• Do not let the appliance become hot enough for any part to glow red.
• Do not install damaged, incomplete or substitute components.
• Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may
be sharp.
• Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid
burns or clothing ignition.
• Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there
are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable safety gate to
keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
• Clothing or other fl ammable material should not be placed on or near the appliance. Objects placed in front of the
appliance must be kept a minimum of 4 feet (1.2m) away from the front face of the appliance.
• Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
• Ensure you have incorporated adequate safety measures to protect infants/toddlers from touching hot surfaces.
• Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
• Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot
surfaces. These screens and guards must be fastened to the fl oor.
• Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
• Under no circumstances should this appliance be modifi ed.
• This appliance must not be connected to a chimney fl ue pipe servicing a separate solid fuel burning appliance.
• Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should
be done by a licensed or qualifi ed service person.
• Do not strike or slam shut the appliance glass door.
• Only doors / optional fronts certifi ed with the appliance are to be installed on the appliance.
• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all
plastic bags, these are not toys and should be kept away from children and infants.
• If the appliance is not properly installed, a house fi re may result. Do not expose the appliance to the elements (ex.
rain, etc.) and keep the appliance dry at all times. Wet insulation will produce an odour when the appliance is used.
• The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as required.
• Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc.
• Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to smoke
spillage in your home.
• Lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or too
green or freshly cut hardwoods. Burning wet unseasoned wood can cause excessive creosote accumulation.
When this is ignited it can cause a chimney fi re that may result in a serious house fi re.
• This appliance is designed to burn natural wood only. Do not burn trash or garbage, lawn clippings / waste,
rubber, waste petroleum products, paints or paint thinners / solvents, plastic, materials containing asbestos,
construction debris, railroad ties or treated wood, manure or animal remains, salt water driftwood or salted
materials, unseasoned wood, coal, charcoal, coloured paper, gift wrapping, cardboard, plywood or particleboard.
Burning these materials may result in release of toxic fumes or render the appliance ineffective and cause smoke.
• Burn wood directly on the fi rebricks. Do not elevate grate or otherwise raise the fi re.
• Do not store wood within appliance installation clearances or within the space required for re-fueling and ash removal.
• Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away
from the home or structure until completely cool.
• Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance.
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage to
decorations, a T.V. or other electronic components.
• If equipped, the catalyst must be installed and in good working order. It is recommended that the catalyst is
inspected at least 3 times per heating season.
3.17G
W415-1473 / A / 09.30.16
2.1 DIMENSIONS
5
2.2 SPECIFICATIONS
31 3/4"
806mm
29 1/8"
740mm
7"
178mm
25 3/8"
12 3/4"
324mm
EN
644mm
6"
152mm
DIA.
SPECIFICATIONS2300
CHAMBER (D.W.H)22 1/2” x 18” x 12” (57.2cm X 45.7cm X 30.5cm )
CAPACITY3.0 FT3 (0.9m3)
APPROX. AREA HEATED**1000-3500 FT2 (305m2 - 1067mm2 )
MAXIMUM HEAT OUTPUT ***85,000 BTU/Hr
HEAT OUTPUT*11,800 - 34,000 BTU/Hr
DURATION LOW FIRE**12 HRS
WEIGHT w/o BRICKS285 LBS (129kg)
WEIGHT OF BRICKS114 LBS (52kg)
IDEAL WOOD LENGTH21” (533mm)
* As tested using test method 28
** Figures will vary considerably with individual conditions.
*** Wolf Steel Ltd. estimated realistic BTU/hr with cordwood logs and regular refueling.
W415-1473 / A / 09.30.16
6
2.3 GENERAL INSTRUCTIONS
EN
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH
LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
THIS APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET. TO
REDUCE RISK OF FIRE OR PREVENT INJURY, DO NOT INSTALL A VENTED OR UNVENTED GAS LOG
BURNING YOUR UNIT WITH THE ASH DUMP DOOR OPEN OR AJAR CREATES A FIRE HAZARD THAT
MAY RESULT IN DISCOLOURATION TO THE GOLD PLATED DOOR, INTERNAL DAMAGE TO THE
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
THIS APPLIANCE AND IT’S COMPONENTS ARE DESIGNED TO BE INSTALLED AND OPERATED AS A
SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED
BY THESE INSTALLATION INSTRUCTIONS, WILL VOID THE LISTING AND MAY VOID THE PRODUCT
WARRANTY. IT MAY ALSO CREATE A HAZARDOUS INSTALLATION. READ THROUGH THESE
INSTRUCTIONS THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM
!
WARNING
THE UNITED STATES.
SET INTO THE APPLIANCE.
APPLIANCE OR A HOUSE CHIMNEY FIRE.
CAREFULLY THROUGHOUT YOUR PROJECT.
4.7
• Before beginning your installation, consult with your local building code agency or fi re offi cials and
insurance representative to ensure compliance.
• Non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke open a
window near the appliance.
• Remove any dust or debris off the top of the appliance before fi ring the appliance as the paint will
become soft as the appliance heats up and will harden as the appliance cures. To cure the paint on
your appliance burn your appliance moderately hot during the fi rst few fi res.
• To keep the gasket from sticking to the appliance as the paint is curing, periodically open the door
every 5-10 minutes.
• For the fi rst two weeks use generous amounts of fuel and burn the appliance with the damper wide
open for an hour as the appliance goes through a process of eliminating moisture in the steel and
fi rebricks. The initial heat output will be reduced while the moisture is being drawn from the appliance
and it will be necessary to build several hot fi res to remove this moisture. DURING THIS PROCESS
DO NOT OVERFIRE THE APPLIANCE. REDUCE THE AMOUNT OF AIR COMING INTO THE
APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED.
W415-1473 / A / 09.30.16
2.4 GENERAL INFORMATION
We suggest that our woodburning hearth products
be installed and serviced by professionals who are
certified in the U.S. by the National Fireplace
Institute® (NFI) as NFI Woodburning Specialists or
who are certified in Canada by
Wood Energy Technical
Training (WETT).
DO NOT OPERATE THIS APPLIANCE WITHOUT THE PEDESTAL INSTALLED.
Your appliance has been specifi cally designed to meet the 2015 U.S.A. EPA particulate emission standards and
has been extensively tested in Canadian and American laboratories. This system is the most effi cient, simple and
trouble free we know and works as follows:
The chimney vent system used on your wood burning appliance should be designed with the least amount of
restriction possible to enable the exhaust products to easily fl ow through it. Chimney vent systems that are too
short or too long can also have an adverse affect on the fl ow of exhaust through it. The wood burning appliance
and chimney vent system also require a suffi cient supply of combustion air not only to support the combustion in
the combustion chamber but to replace the exhaust leaving it so it can fl ow freely up through the vent system and
out into the atmosphere. It is the correct balance of combustion air and the chimney vent system that will ensure
the appliance provides you with its optimum performance.
Combustion air enters through two holes in the bottom
which can be adjusted by a single air control. Air from
the front hole goes up on either side of the door into
a preheating airwash located across the top and then
down the window to feed the fi re and also to ensure that
the glass remains clean. Air from this hole also feeds
directly into the combustion chamber at hearth level.
Secondary air from the rear hole travels up the back in
the secondary air housing to the manifold located at the
top and shoots out laterally to oxidize the gases below
the smoke exit.
The combustion chamber is lined with high temperature
fi rebrick on both sides, the back and across the bottom,
with a layer of fi bre baffl es at the top to maintain a
high temperature in the combustion chamber so that
gases mixing with the preheated air from the secondary
air manifold tube are easily ignited and burned. The
appliance sides and back are shielded to direct the heat
upwards and forwards into the room.
!
WARNING
PRIMARY AIR
SECONDARY AIR
FLUE GLASS
HOT SECONDARY AIR
FIBRE BRICKS
REFRACTORY
2 SIDES, BACK
& BOTTOM
7
EN
CERAMIC
GLASS
AIR CONTROL
CLOSED
OPEN
COMBUSTION AIR
INTAKE
Be sure to provide suffi cient combustion air. There are many other appliances in your home competing for air such
as: a kitchen range hood, forced air heating devices or a bathroom exhaust fan.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
After extended periods of non-operation such as following a vacation or a warm weather season, the appliance
may emit a slight odour for a few hours. This is caused by dust particles on the fi rebox burning off. Open a window
to suffi ciently ventilate the room.
CALIFORNIA PROP 65 WARNING:
Use of this product may produce smoke which contains
chemicals known to the State of California to cause cancer,
birth defects, or other reproductive harm.
If optional ash drawer is purchased, ensure that the ash
dump door is tightly closed, allow the door to snap shut
dislodging anything (ashes or pieces of coal) that may be
stuck in the opening.
If outside air is utilized, you should never experience a shortage of combustion air. If you choose not to utilize
outside air and experience draft or smoking problems, you may need to open a door, a window or otherwise
provide some method of supplying combustion air to the appliance.
W415-1473 / A / 09.30.16
8
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emissions standards. Not approved for sale after May 15, 2020. Certifié conforme à la norme
d’ émanation de particles de 2015. Non approuvé pour la vente après le 15 mai, 2020. 40 CFR Part 60, Subpart AAA. 2.8 Grams Per
Hour / 2015 Crib Wood / 2.8 Grammes par heure / Crib Wood 2015
CC
)CK WALL (M
4545
WALL (M/L)WALL (M/L)
(
/
)
A
S
OLE PO
SUR UNE BA
QUI DOIT DÉPASSER LQUI DO
OR DOUDO
NTLY. UNDER CERTAIN
ITIONS OF USE CREOSOTE
NECT POWERNECT POWER
ENTENT
OIS SEULEMENT. N’UTILISEZ PAS DEIS SEULEMENT. N’UTILISEZ PAS
CHENET OU NE SURÉLEVEZ PAS LENET OU NE SURÉLEVEZ PAS L
SU
RE.
A
ENT: RISQU
CONDITCONDI
CRÉOCRÉ
2.5 RATING PLATE INFORMATION
EN
For rating plate location, see
“INSTALLATION OVERVIEW” section.
This illustration is for reference only.
Refer to the rating plate on the appliance
for accurate information.
NOTE: The rating plate must remain
with the appliance at all times. It must
not be removed.
LISTED SOLID FUEL BURNING SPACE HEATER / POÊLE À COMBUSTIBLE SOLIDE
9700539 (WSL)
4001657 (NGZ)
INSTALL AND USE ONL Y IN
ACCORDANCE WITH THE
MANUFACTURER’S INSTRUCTIONS
AND LOCAL BUILDING CODES.
MINIMUM CEILING HEIGHT: 7FT
(2.13m)
HEARTH EXTENSION / COMBUSTIBLE FLOOR PROTECTION: IF
INSTALLED ON A COMBUSTIBLE
FLOOR, UNIT MUST BE PLACED ON
A NON-COMBUSTIBLE FLOOR
PROTECTOR EXTENDING 18”
(455mm) IN FRONT AND 8” (205mm) TO
THE SIDES AND BACK.
CHIMNEY TYPE: MINIMUM 6”
(152mm) DIAMETER APPROVED
RESIDENTIAL TYPE FOR MOBILE
HOME USE A CHIMNEY LISTED TO
ULC S629 IN CANADA OR UL 103HT IN
THE USA.
CHIMNEY CONNECTOR: 6” (152mm)
DIAMETER MINIMUM 24 GAUGE
STEEL MINIMUM CLEARANCE
FROM HORIZONTAL CONNECTOR
AND CEILING 18” (455mm).
DO NOT OBSTRUCT SPACE UNDER
HEATER.
SPECIAL METHODS ARE
REQUIRED WHEN PASSING A
CHIMNEY THROUGH A WALL OR
CEILING. SEE INSTRUCTIONS AND
BUILDING CODES.
DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
FUEL: FOR USE WITH WOOD ONLY.
DO NOT USE GRATE OR ELEVATE
FIRE. BUILD WOOD FIRE DIRECTLY
ON HEARTH.
WARNING: RISK OF SMOKE
SPILLAGE. OPERATE ONLY WITH
DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH
CERAMIC GLASS.
DO NOT OVERFIRE. IF HEATER OR
CHIMNEY CONNECTORS GLOW,
YOU ARE OVERFIRING. INSPECT
AND CLEAN CHIMNEY
FREQUENTLY. UNDER CERTAIN
CONDITIONS OF USE CREOSOTE
BUIL D - U P MAYOCCUR RAPIDLY .
OPTIONAL BLOWER KIT: EP-62,
115V, 60HZ, 0.82AMP. ROUTE CORD
AWAY FROM UNIT.
DANGER: RISK OF ELECTRICAL
SHOCK. DISCONNECT POWER
BEFORE SERVICING UNIT.
4001659 (WUSA)
4001658 (NAC)
HOMOLOGUÉ TESTED TO: / TESTÉ SELON : UL1482 / ULC S627
POUR INSTALLATION ET UTILISATION
CONFORMÉMENT AUX INSTRUCTIONS
DU FABRICANT ET AUX CODES LOCAUX
DU BÂTIMENT.
HAUTEUR DE PLAFOND MINIMAL 7PI
(2,13m).
PROLONGEMENT D’ÂTRE/PROTECTION
DU PLANCHER COMBUSTIBLE: SI
INSTALLÉ SUR UN PLANCHER
COMBUSTIBLE, L’APPAREIL DOIT ÊTRE
PLACÉ SUR UNE PLAQUE PROTECTRICE
INCOMBUSTIBLE S’ÉTENDANT SUR 18”
(455mm) À L’AVANT ET 8” (205mm) À
L’ARRIÈRE ET SUR LES CÔTÉS.
TYPE DE CHEMINÉE: DIAMÈTRE MINIMAL
DE 6” (152mm) APPROUVÉE POUR USAGE
RÉSIDENTIEL. MAISON MOBILE
EMPLOYEZ UNE CHEMINÉE
HOMOLOGUÉE ULC S629 AU CANADA OU
UL 103HT AUX ÉTATS-UNIS.
RACCORD DE CHEMINÉE: DIAMÈTRE DE
6” (152mm) D’ACIER DE CALIBRE 24
MINIMUM. 18” (455mm) DE DÉGAGEMENT
MINIMAL ENTRE LE RACCORD
HORIZONTAL ET LE PLAFOND.
NE RIEN ENTREPOSER SOUS
L’APPAREIL.
DES MÉTHODES SPÉCIALES SONT
REQUISES LORSQU’UNE CHEMINÉE
TRAVERSE UN MUR OU UN PLAFOND.
VOIR LES INSTRUCTIONS ET LES CODES
DU BÂTIMENT.
NE PAS RACCORDER À LA CHEMINÉE
D’UN AUTRE APPAREIL.
COMBUSTIBLE: POUR USAGE AVEC LE
BOIS SEULEMENT. N’UTILISEZ PAS DE
CHENET OU NE SURÉLEVEZ PAS LE
BOIS. PRÉPAREZ LE FEU DIRECTEMENT
R L’ÂTRE.
SUR L’ÂTRE.
VERTISSEMENT: RISQUE
AVERTISSEMENT: RISQUE
D’ÉCHAPPEMENT DE FUMÉE. TENIR LA
PORTE FERMÉE LORSQUE LE POÊLE
FONCTIONNE. REMPLACEZ LA VITRE PAR
UNE VITRE EN CÉRAMIQUE SEULEMENT.
NE SURCHAUFFEZ PAS L’APPAREIL. SI
L’APPAREIL OU LES RACCORDS
ROUGEOIENT, L’APPAREIL SURCHAUFFE.
INSPECTEZ ET NETTOYEZ LA CHEMINÉE
FRÉQUEMMENT. DANS CERTAINES
CONDITIONS, DES DÉPÔTS DE
CRÉOSOTE PEUVENT SE FORMER
RAPIDEMENT.
SOUFFLERIE OPTIONNELLE: EP-62, 115V,
60HZ, 0,82A. TENEZ LE CORDON
ÉLECTRIQUE LOIN DE L’APPAREIL.
DANGER: RISQUE DE SECOUSSE
ÉLECTRIQUE. DÉBRANCHEZ AVANT DE
PROCÉDER À L’ENTRETIEN.
MODEL / MODÈLE - EPA 1900
1900
S9
CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTIONS IN YOUR LOCAL AREA. A MINIMUM
CLEARANCE OF 18 INCHES (457mm) TO THE CHIMNEY CONNECTOR
MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPRÈS DES AUTORITÉS LOCALES DU
BÂTIMENT ET DU SERVICE DES INCENDIES AU SUJET DES
RESTRICTIONS ET DES INSPECTIONS D’INSTALLATION DANS VOTRE
RÉGION. UN DÉGAGEMENT MINIMALE DE 18 POUCES (457mm)
JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR
L’AUTORITÉ AYANT JURIDICTION.
BACK WALL (M/A)
B
IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT
MUST BE PLACED ON ANAPPROVED NON-COMBUSTIBLE HEARTH
PAD, THAT EXTENDS 8” (200MM) BEYOND THE STOVE SIDES AND
BACK, AND 18” (455MM) TO THE FRONT.
SI LE POÊLE EST INSTALL
I LE P
ÊTRE PLACÉ
ÊTREPLACÉ SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE
QUI DOIT DÉPASSER LES CÔTÉS ET L ’AMÉRE DU
ET SE PROLONGER DE 18” (455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL USING SINGLE
OR DOUBLE WALL CHIMNEY CONNECTORS / DÉGAGEMENT
MINIMAL AUX MATÉRIAUX COMBUSTIBLE AVEC DES CONDUITS DE
RACCORDEMENT À PAROI SIMPLE OU À DOUBLE PAROI
THIS WOOD APPLIANCE NEEDS PERIODIC INSPECTION AND REPAIR
FOR PROPER OPERATION. CONSULT THE OWNER'S MANUAL FOR
FURTHER INFORMATION. IT IS AGAINST UNITED STATES FEDERAL
REGULATIONS TO OPERATE THIS WOOD APPLIANCE IN A MANNER
CONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE
OWNER'S MANUAL.
CET APPAREIL AU BOIS DOIT FAIRE L'OBJET D'UNE INSPECTION ET
D'UN ENTRETIEN PÉRIODIQUES POUR UN FONCTIONNEMENT
ADÉQUAT. CONSULTEZ LE MANUEL D'INSTRUCTIONS POUR PLUS
D'INFORMATION. LES RÈGLEMENTS FÉDÉRAUX DE L'ÉTATS-UNIS
INTERDISENT D'UTILISER CET APPAREIL DE CHAUFFAGE D'UNE
MANIÈRE ALLANT À L'ENCONTRE DES INSTRUCTIONS DE
FONCTIONNEMENT CONTENUES DANS CE MANUEL.
BACK WALL (M/A)
BACK WALL (M/A
L
M
45°
A
IDE WALL
SIDE WALL (M/L)
É SUR UN PLANCHER COMBUSTIBLE, IL DOIT
FROM HEATER / DU POÊLE
RESIDENTIAL / RÉSIDENTIEL
A. 22IN/PO (560 mm)
B. 12IN/PO (305mm)
C. 8IN/PO (205mm)
8"
C
SIDE WALL (M/L)
18"
POÊLE DE 8” (200mm)
8"
MANUFACTURE DATE: / DATE DE FABRICATION:
YEAR:
MONTH:
2016
243658710912111
CAUTION:
ATTENTION:
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emissions standards. Not approved for sale after May 15, 2020. Certifié conforme à la norme
d’ émanation de particles de 2015. Non approuvé pour la vente après le 15 mai, 2020. 40 CFR Part 60, Subpart AAA. 2.8 Grams Per
Hour / 2015 Crib Wood / 2.8 Grammes par heure / Crib Wood 2015
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
20172018
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AW A Y . CONT ACT MA Y CAUSE
SKIN BURNS.
QUAND L’APP AREIL FONCTIONNE, LA SURFACE DEVIENT
CHAUDE. NE PAS TOUCHER. TENIR LES ENF ANTS, LES
VÊTEMENTS ET LES MEUBLES À L’ÉCART . LE CONT ACT PEUT
CAUSER DES BRÛLURES À LA PEAU.
EPA1900
20192020
W385-2032 / B
8"
W415-1473 / A / 09.30.16
1900 SERIES RATING PLATE ILLUSTRATED
3.0 PRE-INSTALLATION PREPARATION
3.1 APPLIANCE PLACEMENT
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the
requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 4 feet (1.2m) of the front of the appliance.
3.2 CLEARANCE TO COMBUSTIBLES
!
WARNING
DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (2.1m)
(CEILING OF ENCLOSURE TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT)
SIDEWALL (A)22" (55.9cm)22" (55.9cm)
SIDEWALL TO FLUE (B)31 3/4" (80.6cm)31 3/4" (80.6cm)
BACK WALL (C)12" (30.5cm)12" (30.5cm)
BACK WALL TO FLUE (D)15 1/2" (39.4cm)15 1/2" (39.4cm)
CORNER (E)8" (203mm)8" (203mm)
CEILING (F)84" (2134mm)84" (2134mm)
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply
with NFPA 211 or CAN/CSA-B365.
E
SIDE WALL
F
W415-1473 / A / 09.30.16
10
3.3 FLOOR PROTECTION
EMBER PROTECTOR:
EN
3.4 OUTSIDE AIR
This appliance must be installed on a non-combustible protector that extends to the front, sides and back of the
appliance as per the minimum requirements below.
NOTE: Ember protection is required for spark and ash shielding, not for limiting fl oor temperatures
from the radiant heat of the appliance. The appliance was designed and safety tested so that without
any protection, the fl oor will not overheat.
L
J
IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING
The following are signs that a fresh air kit may be required:
• When there is combustion present: Wood burns
poorly, smoke spills, back-draft takes place and
your chimney does not draw steadily.
• In the winter there is too much condensation on
the windows.
• Opening a window seems to alleviate the above
symptoms.
• A ventilation system is installed in the house.
• Other devices are present that exhaust house air.
• The house has tight fi tting windows and/or is
equipped with a well-sealed vapour barrier.
11 11/16"
13 3/8"
340mm
If possible connect the air intake at the pedestal’s back or bottom to the outside with a 4" (102mm) diameter
fresh air kit available at your local authorized dealer / distributor.
297mm
W415-1473 / A / 09.30.16
4.0 INSTALLATION
11
!
WARNING
WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION.
CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS
NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF
COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE
BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES
ARE HAZARDOUS. DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN
FROM ATTIC SPACES, BASEMENTS OR ABOVE THE ROOFING WHERE OTHER HEATING APPLIANCES
OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR. THESE PRECAUTIONS WILL REDUCE THE
POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL. THE OUTSIDE AIR INLET MUST
REMAIN CLEAR OF LEAVES, DEBRIS ICE AND/OR SNOW. IT MUST BE UNRESTRICTED WHILE
APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE
AND AN INABILITY TO MAINTAIN A FIRE. SMOKE SPILLAGE CAN ALSO SET OFF SMOKE ALARMS.
NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE APPLIANCE MUST NOT BE
INSTALLED AGAINST VAPOUR BARRIERS OR EXPOSED INSULATION. LOCALIZED OVERHEATING
COULD OCCUR AND A FIRE COULD RESULT.
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT
AIR, GRILLE OR LOUVRE OPENINGS. DO NOT ADD A HOOD.
TO PREVENT PERSONAL INJURY KEEP HAND TOOLS IN GOOD CONDITION, SHARPEN CUTTING
EDGES AND MAKE SURE TOOL HANDLES ARE SECURE.
ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO THE ENCLOSURE TO PREVENT FIRES.
68.3C
EN
W415-1473 / A / 09.30.16
12
4.1 CHIMNEY
EN
!
WARNING
NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE.
THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO
COMBUSTIBLE CHASE MATERIALS TO CAUSE FIRE.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE.
TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING
THE PROVISIONS OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.
TO PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE
WEATHER, WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST RESISTANT PAINT.
DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHER
MATERIAL. INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO
OVERHEAT.
MAINTAIN A MINIMUM 2” (50.8mm) AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT
ALL TIMES (EXCLUDING THE CHIMNEY CONNECTOR). FAILURE TO MAINTAIN THIS 2” (50.8mm) AIR
CLEARANCE WILL CAUSE A STRUCTURE FIRE. NEVER FILL THIS SPACE WITH ANY TYPE OF MATERIAL.
DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP, STORM COLLAR AND
TERMINATION CAP ARE PACKAGED WITH THESE PARTS. MINIMUM CLEARANCE TO
COMBUSTIBLES WILL VARY DEPENDING ON THEIR DESIGN.
DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIAL
TO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED.
FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOOR AREA.
THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT
ABOVE THE APPLIANCE. ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS A
MINIMUM OF 1/4” (21.2mm) PER FOOT (METER) AND ALL CONNECTIONS MUST BE TIGHT AND
SECURED BY THREE SHEET METAL SCREWS EQUALLY SPACED. AN UNINSULATED SMOKE PIPE
SHALL NOT PASS THROUGH AN ATTIC, ROOF SPACE, CLOSET, OR SIMILAR CONCEALED SPACE,
OR THROUGH A FLOOR, CEILING, WALL OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTION.
DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION.
63.8A
Your appliance may be connected to a factory built or masonry chimney. If you are using a factory built
chimney, it must comply with ULCS629 (Canada) or UL103 HT (USA) standards. It must therefore be a 6"
(152mm) HT Type (2100°F) chimney. Use only specifi ed components with no substitutions. It is extremely
important that it be installed according to the manufacturer's specifi cations. The manufacturer's installation
instructions and specifi ed clearances should always be followed in accordance with local and national codes.
In Canada the CSA B365 and the CSA C22.1 installation codes are to be followed. In the USA the ANSI NFPA
70 and ANSI NFPA 211 installation codes are to be followed.
Chimney and chimney connector must be in good condition and kept clean.
W415-1473 / A / 09.30.16
4.1.1 CHIMNEY CONNECTION
13
Your chimney connector and chimney must have the same diameter as the appliance’s exhaust fl ue outlet.
The appliance pipe must be made of aluminized or cold roll steel with a minimum 24 gauge thickness. It is
strictly forbidden to use galvanized steel.
A 6” (152mm) diameter single wall chimney connector, used to connect the appliance to the chimney, must be
installed with the crimped end toward the appliance. This will ensure that the moisture which condenses from the
burning wood will fl ow back into the fi re chamber. Each joint in the chimney connector must be secured with at
least three sheet metal screws.
For installation of your chimney connector, the following recommendations may be useful.
• The chimney connector must be short and straight. For optimum performance it is recommended that
all horizontal runs have a minimum 1/4” (6mm) rise per foot, with the upper end of the section toward
the chimney. For safe and proper operation of the appliance, see “INSTALLATION” instructions.
• To insure a good draft, the total horizontal vent length should not exceed 40% of the chimney height
above the appliance. All horizontal smoke pipe must slope slightly upwards a minimum of 1/4”
(6.4mm) per foot (meter) and all connections must be tight. In the case of vertical installation, the total
length of the connector can be longer and connected without problem to the chimney at the ceiling
level.
• There should never be more than two 90° elbows in the entire connector and chimney system. Never
start with a 90° elbow. Always go up vertically for at least 2 feet (0.6m) from the fl ue collar before using
a 90° elbow.
• The connector must not pass through any combustible material, nor may it pass through a concealed
space (such as an attic, roof space, or closet). If passing through a wall, ceiling, or into a masonry
chimney, use either chimney components listed for that specifi c use, or means acceptable to local
authorities having jurisdiction over the installation.
EN
This appliance must be connected to:
A.A chimney complying with the requirements for
Type HT chimneys in the Standard for Chimneys,
Factory-Built, Residential Type and Building Heating
Appliance, or
B.A code-approved masonry chimney with a fl ue
liner. Vent the stove into a masonry chimney or an
approved, insulated solid-fuel stainless-steel chimney
with as short and straight a length of 6” (152.4mm)
diameter
to a masonry chimney must be by a metal or masonry
thimble cemented in place.
chimney connector as possible. Connection
TOWARD
APPLIANCE
MALE END OF
CONNECTOR
OR CHIMNEY
PIPE
FLUE GAS
DIRECTION
58.1B
W415-1473 / A / 09.30.16
14
A
4.1.2 ADDING SECTIONS
dd chimney sections, according to the manufacturers installation instructions. The chimney must extend at
EN
least, 3 feet (1m) above its point of contact with the roof and at least 24 inches (61cm) higher than any wall,
roof, building or obstacle within 10 feet (3m) horizontally.
LESS THAN
10 FEET
(3m)
24” (61cm)
MIN
3 FT (1m)
MIN
3 FT
(1m)
MIN
24” (61cm) MIN
10 FT (3m)
TO NEAREST
ROOFLINE
RIDGE
LESS THAN
10 FT (3m)
10 FEET
(3m)
OR MORE
3 FT (1m)
3 FT (1m)
MIN
24” (61cm)
MIN
MIN
FLAT ROOF
WALL
59.1B
W415-1473 / A / 09.30.16
4.1.3 TYPICAL THROUGH THE CEILING
15
A.Move the stove into position with the fl ue centered, midpoint between two
joists to prevent having to cut them. Use a plumb bob to line up the center.
B. Cut and frame an opening in the ceiling to provide a 2” (50.8mm) clearance
between the outside of the chimney and any combustible material. DO NOT
FILL THIS SPACE WITH ANY TYPE OF MATERIAL.
Nail headers between the joist for extra support.
Firestop spacers must be placed on the
bottom of each framed opening in any fl oor
or ceiling that the chimney passes through.
HEADERS
If your chimney system is enclosed within
the attic area, a rafter radiation shield is
required.
C.Hold a plumb bob from the underside of
the roof to determine where the opening in
FIRESTOP SPACER UNDERSIDE OF JOIST
the roof should be. Cut and frame the roof
opening to maintain proper 2” (50.8mm) clearances.
NOTE: The chimney must be supported at the ceiling or roof so that it’s
weight does not rest on the appliance and must comply with it’s
manufacturer’s instructions.
LISTED
CHIMNEY
SPECIFIED
CLEARANCE
MAINTAIN
2” (50.8mm)
CLEARANCE
LISTED CHIMNEY
EN
TERMINAL
STORM
COLLAR
FLASHING
ROOF
INSULATION
CEILING
SUPPORT
TO STOVE
FLOOR
PROTECTOR
CHIMNEY
SUPPORT
CHIMNEY
CONNECTOR
COMBUSTIBLE
WALL
60.1B
W415-1473 / A / 09.30.16
16
FLOOR
PROTECTOR
CHIMNEY
CONNECTOR
COMBUSTIBLE
WALL
CLEARANCE
EAVE
RAFTER
CLEARANCE WITH FIRESTOP
CEILING JOIST
THIMBLE
4.1.4 TYPICAL THROUGH THE WALL
If possible, design the installation so that the connector does not pass through a combustible wall. If during
EN
your installation you must pass through a combustible wall, check with your building inspector before you
begin. Also check with the chimney connector manufacturer for any specifi c requirements.
Consult with your dealer regarding special connection components available for use for wall pass-throughs.
Use only parts that have been tested and listed for use in a wall pass-through.
COMBUSTIBLE
OUTSIDE WALL
SECTION
LISTED
CHIMNEY
TO
STOVE
THIMBLE
PIPE
WALL SPACER
FOR OUTSIDE
LISTED
CHIMNEY
2” (50.8mm)
CLEARANCE
INSULATED
SUPPORT
WALL
“T”
WALL
ROOF
COMBUSTIBLE
CHIMNEY
CONNECTOR
MAINTAIN 2”
(50.8mm) CLEARANCE
THROUGH EAVE
CEILING
TERMINAL
STORM
COLLAR
FLASHING
4.1.5 TYPICAL EXISTING MASONRY
You can also install your appliance using your existing
masonry chimney. To do so, follow the guidelines
below. Use a factory-built thimble, or construct
your own brick thimble. If you are using a masonry
chimney, it is important that it be built in compliance
with the specifi cations of the Building Code in
your region. It must normally be lined with fi re clay
bricks, metal or clay tiles sealed together with fi re
cement. (Round fl ues are the most effi cient). The
maximum fl ue size is 8” (203.2mm) x 8” (203.2mm)
square or 6” (152.4mm) round. For greater diameters
it is necessary to install a 6” stainless steel liner.
FLOOR
PROTECTOR
COMBUSTIBLE
WALL
61.1A
62.1A
W415-1473 / A / 09.30.16
5.0 FINISHING
17
5.1 DOOR REMOVAL / INSTALLATION
A.Pivot the door open and lift up to
clear the bushings. Do not pivot the
door any further than necessary.
B.Carefully set the door aside and
pull the pins out from the door
bushings. Repeat in reverse order
to install the door.
C.Install the door in reverse order.
5.2 DOOR HANDLE INSTALLATION
BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT
MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE.
DO NOT STRIKE OR SLAM DOOR.
NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT.
!
WARNING
PINS
EN
NOTE: DOOR MAY NOT BE AS
ILLUSTRATED
FRONT VIEW
DOOR
DOOR
HANDLE
SPRING
WASHER
SPACER
DOOR HANDLE
LATCH
LOCK
NUT
NOTE: Position of
door handle latch.
98.1
W415-1473 / A / 09.30.16
18
5.3 BRICKS AND BAFFLE INSTALLATION
EN
!
WARNING
OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE
TEMPERATURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING
ENCLOSURE.
With appliance and chimney installation completed, move the bricks into place for your appliance as
illustrated.
A. Install the bottom bricks, working from the back of the appliance forward.
B. Before installing the back bricks, loosen the screw holding the brick retainer and ensure that it has
been moved forward. Install the six bricks along the back wall by pivoting the bricks up under the
brick retainer. Retighten the screw.
C.Referring to the appropriate illustration for your appliance, install the fi rst two rows of side bricks
as shown. Pivot fi bre baffl e into place, with the brick retainer down and towards the outside of the
appliance. Slide top row of bricks into place to support the baffl e. Baffl e must sit fl at on outside
row of bricks as well as the fl ange on the manifold shield. Push baffl e all the way to the rear of the
fi rebox, leaving a minimum of a 1" (25mm) gap along the front. This will allow fl ue gases to escape
the fi rebox.
D.Install the 4 bricks along the front opening.
NOTE: Do not operate if baffl e and manifold shield are not in position.
(All Firebricks are 1 1/4” (32mm) Thick)
FIREBRICK
DIMENSIONS
4 1/2” x 9” (114mm x 229mm)W090-0015 (X23)
A
PAR T #
F
FIREBRICK
DIMENSIONS
RS Notched Brick
4 1/2” x 9” (114mm x 229mm)
PAR T #
W090-0208 (X1)
B
C
D
E
3” x 9” (76mm x 229mm)W090-0166 (X4)
4 1/2” x 4 1/2” (114mm x 114mm)W090-0003 (X2)
3” x 9” (76mm x 229mm)W090-0002 (X2)
LS Notched Brick
4 1/2” x 9” (114mm x 229mm)
NOTE: BRICKS
E & F ARE
NOTCHED AT
REAR.
F
G
B
B
E
A
A
A
A
H
W090-0207 (X1)
C
A
A
G
H
2 1/4” x 9” (57mm x 229mm) W090-0018 (X1)
2 1/4” x 6 1/8” (57mm x 79mm)W090-0019 (X1)
4 1/2” x 2 1/2” (114mm x 64mm)W090-0016 (X1)
I
J
4 1/2” x 6 1/2" (114mm x 165mm)
Ash Plug
W510-0011 (X1)
BRICK
RETAINERS
E
A
A
A
A
I
A
D
A
A
B
A
A
J
D
A
A
B
F
C
A
A
A
A
AA
(Fibre Baffles)
W018-0130 X2
W415-1473 / A / 09.30.16
6.0 OPTIONAL KIT INSTALLATIONS
19
6.1 BLOWER KIT INSTALLATION
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
Provisions have been made on the appliance to install an optional blower kit (EP65) that comes complete
with a variable speed switch to turn the blower on and off, as well as adjusting the blower speed and a
thermostatic sensor to thermally activate the blower.
Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to
prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from
this condition is not covered by the warranty policy.
Use of the blower increases the output of heat.
TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
VOID THE WARRANTY AND CERTIFICATION.
CONTACT WITH MOVING OR HOT OBJECTS.
!
WARNING
CORD BENEATH THE APPLIANCE.
EN
51.5
6.1.1 BLOWER INSTALLATION
A. Ensure the thermal disc bracket is in the correct position, refer to Figure 1.
B. Remove the knock-out from the back of the appliance.
C. Install the blower and housing as shown using the 4 screws supplied, refer to Figure 2.
D. Loosen the thermal disc bracket (2 screws) and slide the bracket until the thermal disc is touching the
rear of the fi rebox and secure.
Fig. 1
THERMAL DISC BRACKET
Fig. 2
KNOCKOUT
SCREWS
BLOWER
THERMAL DISC
BRACKET
W415-1473 / A / 09.30.16
20
7.0 OPERATION
EN
!
WARNING
ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT DURING
START UP AND RE-FUELING. ALWAYS WEAR GLOVES TO PREVENT INJURY. DO NOT LEAVE THE
FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED AS UNSTABLE WOOD COULD FALL OUT OF
THE FIRE CHAMBER CREATING A FIRE HAZARD TO YOUR HOME.
NEVER LEAVE CHILDREN UNATTENDED WHEN THERE IS A FIRE BURNING IN THE APPLIANCE.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID,
OR SIMILAR LIQUIDS TO START OR ‘FRESHEN UP’ A FIRE IN THIS APPLIANCE. KEEP ALL SUCH
LIQUIDS WELL AWAY FROM THE APPLIANCE WHILE IT IS IN USE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE SHOULD BE KEPT A MINIMUM OF 4 feet
(1.2m) FROM THE FRONT FACE.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE
TESTING AUTHORITY IS CONSIDERED BREACHING CSA B365 (CANADA) AND ANSI NFPA 211 (USA).
OPEN AIR CONTROL (AND DAMPER WHEN FITTED) BEFORE OPENING FIRING DOOR.
HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS. WEAR GLOVES TO OPERATE YOUR APPLIANCE.
BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD
THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE.
THIS WOOD APPLIANCE HAS A MANUFACTURER-SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL REGULATIONS IN THE UNITED STATES TO ALTER THIS
SETTING OR OTHERWISE OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
Your Timberwolf EPA listed product is a Hi-tech appliance, designed with the most advanced technology. The
appliance is extremely airtight. It has an exclusive direct outside air supply (optional kit), a safety feature
designed to prevent spillage, and to keep your house free of carbon monoxide, in case of a down drafting
chimney or an internal negative pressure. This appliance requires periodic inspection and repair for proper
operation. It is against federal regulations in the United States to operate this appliance in a manner
inconsistent with operating instructions in this manual.
The fi rst fi re(s) in your appliance will be diffi cult to get going and keep going with little amount of heat being
generated. This is a result of the moisture being driven out of the fi re brick. During the break-in period (the fi rst 2 or
3 fi res) create only small, fi res using kindling; this will allow the fi rebrick to cure. Do not be alarmed if small hairline
cracks develop in the fi rebrick. This is a normal occurrence and does not pose a safety hazard. The paint may also
smell a little for the fi rst few fi res as it cures and you may wish to open a door or window to alleviate the smell.
To start, a brisk fi re is required. Place loosely crumpled paper on the fl oor of the appliance and cover with dry kindling.
Open the air control fully by sliding control all the way to the right. Light the paper and leave the door slightly ajar (one
inch) until all kindling is burning. To maintain a brisk fi re, a hot coal bed must be established and maintained.
During the refueling and rekindling of a cool fi re, or a fi re that has been burned down to the charcoal phase,
operate the appliance at a medium to high fi ring rate for about 10 minutes to ensure the temperature reaches
600°F (315°C)
Slowly add larger wood (2x4 size pieces). Lay the pieces lengthwise from side to side in the hot coal bed with a
shallow trench between, so that the primary air can fl ow directly into this trench and ignite the fuel above. When the
fi re seems to be at its peak, medium sized logs may be added. Once these logs have caught fi re, carefully close the
door. (Closing the door too quickly after refueling will reduce the fi rebox temperature and result in an unsatisfactory
burn.) Remember it is more effi cient to burn medium sized wood, briskly, and refuel frequently than to load the
appliance with large logs that result in a smouldering, ineffi cient fi re and dirty glass.
W415-1473 / A / 09.30.16
21
As soon as the door is closed, you will observe a change in the fl ame pattern. The fl ames will get smaller and lazier
because less oxygen is getting into the combustion chamber. The fl ames, however, are more effi cient. The fl ames
will remain lazy but become larger again as soon as the fi rebricks have been heated thoroughly and the chimney
becomes heated and provides a good draft. At this point, the roaring fi re that you see when the door is opened is
wastefully drawing heated room air up the chimney, certainly not desirable. Always operate with the door fully closed
once the medium sized logs have caught fi re.
You can now add larger pieces of wood and operate the appliance normally. Once the appliance is entirely
hot, it will burn very effi ciently with little smoke from the chimney. There will be a bed of orange coals in the
fi rebox and secondary fl ames fl ickering just below the top baffl es. You can safely fi ll the fi rebox with wood
to the top of the door and will get best burns if you keep the appliance pipe temperatures between 250°F
(120°C) and 450°F (270°C). A surface thermometer will help regulate this.
Without a appliance thermometer, you are working blindly and have no idea of how the appliance is
operating! An appliance thermometer offers a guide to performance and should be located 18" (457mm)
above the fl ue collar. Install the thermometer according to manufacturers instructions.
Can’t get the fi re going?
Use more kindling and paper. Assuming the chimney and vent are sized correctly and there is suffi cient
combustion air, the lack of suffi ciently dry quantities of small kindling is the problem. Thumb size is a good
gauge for small kindling diameter.
Can’t get heat out of the appliance?
One of two things may have happened. The appliance door may have been closed prematurely and the
appliance itself has not reached optimum temperature. Reopen the door and/or draft control to re-establish
a brisk fi re. The other problem may have been wet wood. The typical symptom is sizzling wood and moisture
being driven from the wood.
EN
7.1 OPTIMUM BURN METHOD
For optimal emissions performance and effi ciency follow these simple guidelines when using your appliance:
A. Maintain a 2" (51mm) deep, hot, glowing red coal bed.
B. Burn dry seasoned wood with less than 20% moisture content and burn so that the glass door
remains clean.
C.A stove thermometer 18" (457mm) up on the single wall stove pipe should indicate 350°F (176°C) as
an average temperature.
D.Maintain a minimal trace of smoke coming from the chimney when the appliance is burning as
intended.
E.Inspect and replace all necessary components such as gaskets, manifolds, glass and other
components which may affect the overall appliance performance.
F.Ensure an adequate draft to control burn rate and temperature.
Refer to “OPERATION” and “MAINTENANCE” sections for detailed information.
W415-1473 / A / 09.30.16
22
7.2 AIR CONTROL
EN
THIS WOOD APPLIANCE HAS A MANUFACTURER-SET MINIMUM LOW BURN RATE AND MAXIMUM
HIGH BURN RATE THAT MUST NOT BE ALTERED. IT IS AGAINST FEDERAL REGULATIONS IN THE
UNITED STATES TO ALTER THIS SETTING OR OTHERWISE OPERATE THIS WOOD APPLIANCE IN A
Draft is the force which moves air from the fi rebox up through the
chimney. The amount of draft in your chimney depends on the length
and diameter of chimney, local geography, nearby obstructions and other
factors including the amount of heat generated by the fi re which can be
measured by an appliance thermometer.
Adjusting the air control regulates the temperature. The draft can be
adjusted from a low burn rate with the handle in fully, to a high rate with
the handle fully out.
Inadequate draft may cause back-puffi ng into the room through the
appliance and chimney connector points and may cause plugging of the chimney. Too much draft may
cause an excessive temperature in the appliance, glowing red appliance parts or chimney connectors or an
uncontrollable burn which can lead to a chimney fi re or permanent damage to the appliance.
Do not operate your appliance for longer than 30 minutes with the draft control on “HIGH” (fully open).
!
WARNING
MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL.
ASH LIP
7.3 FIRE EXTINGUISHERS / SMOKE & CARBON MONOXIDE DETECTORS
NOTE: Always check your smoke and CO detectors are working properly.
All homes with a solid fuel burning appliance should have at least one fi re extinguisher in a central location,
known to all and at least one smoke detector and carbon monoxide (CO) detector in the room containing the
appliance. If the smoke detector sounds an alarm, correct the cause but do not de-activate or relocate the
smoke detector. If the carbon monoxide detector sounds an alarm, immediately vent the area, evacuate and
call your local fi re department.
91.1A
W415-1473 / A / 09.30.16
Loading...
+ 50 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.