Napoleon Installation And Operating Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
MODEL 1100ML, 1100C, 1400ML & 1400C MEET THE 2015 U.S ENVIRONMENTAL PROTECTION AGENCY (E.P.A) CRIB WOOD EMISSION LIMIT FOR WOOD
APPLIANCES SOLD AFTER MAY 15, 2015, 40 C.F. R. PART 60. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO
STANDARDS: CSA B366.2, ULC S627, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
1100ML, 1100C,
1400ML, 1400C
LEG MODELS
SAFETY INFORMATION
EN
FR
PG
37
!
WARNING
If the information in these instructions is not followed exactly , a
fi re or explosion may result causing property damage, personal
injury or death. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage,
bodily injury or even death. Please read entire manual before
you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. T o reduce risk of fi re or injury , do not install an unvented
gas log set into the appliance.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too close
can catch fi re.
- Children and pets must be kept from touching the appliance when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi re authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- At least 14 square inches (90.3 square centimeters) of outside air must be
admitted to the room or directly to the unit through a 4” (101.6mm) diameter
pipe.
- This appliance is designed to burn natural wood only. Higher effi ciencies
and lower emissions generally result when burning air dried seasoned
hardwoods, as compared to softwoods or to green or freshly cut hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc.
- Do not burn trash or garbage, lawn clippings / waste, rubber, waste petroleum
products, paints or paint thinners / solvents, plastic, materials containing
asbestos, construction debris, railroad ties or treated wood, manure or animal
remains, salt water driftwood or salted materials, unseasoned wood, coal,
charcoal, coloured paper, cardboard, plywood or particleboard.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to
achieve heat output rates that exceed design specifi cations can result in steel
distortion and damage.
1400ML Illustrated
!
WARNING
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
5.2 DOOR REMOVAL / INSTALLATION (1100ML / 1400ML) 19
5.3 1100C/1400C DOOR REMOVAL / INSTALLATION 19
5.4 1400C CAST LID LEVELLING 20
5.5 DOOR HANDLE INSTALLATION 20
5.6 BRICKS AND BAFFLES INSTALLATION 21
6.0 OPTIONAL KIT INSTALLATIONS 22
6.1 OPTIONAL BLOWER INSTALLATION 22
6.2 OPTIONAL ASH DRAWER (1100ML/1400ML ONLY) 22
7.0 OPERATION 23
7.1 OPTIMUM BURN METHOD 24
7.2 AIR CONTROL 24
7.3 FIRE EXTINGUISHERS / SMOKE & CARBON MONOXIDE DETECTORS 25
7.4 LIGHTING A FIRE 25
7.4.1 FLASH FIRE 25
7.4.2 EXTENDED FIRE 25
7.5 SMOKING 25
8.0 MAINTENANCE 26
8.1 ASH REMOVAL PROCEDURES 26
8.1.1 APPLIANCES WITHOUT ASH PAN (1100ML/1400ML ONLY) 26
8.1.2 APPLIANCES WITH ASH PAN 26
8.2 CREOSOTE FORMATION AND REMOVAL 26
8.3 RUNAWAY OR CHIMNEY FIRE 27
8.4 CHIMNEY CLEANING 27
8.5 GLASS REPLACEMENT 28
8.6 GASKET REPLACEMENT 28
8.7 CARE OF GLASS 29
8.8 CARE OF PLATED PARTS 29
8.9 WOOD 30
9.0 REPLACEMENTS 31
10.0 TROUBLESHOOTING 33
11.0 WARRANTY 34
12.0 SERVICE HISTORY 35
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
W415-1467 / 04.22.15
1.0 INSTALLATION OVERVIEW
3
1400PL ILLUSTRATED
Door, see “DOOR AND
HANDLE INSTALLATION”
section.
Legs, see “LEG
INSTALLATION”
section.
Draft, see “AIR CONTROL”
section.
Rating Plate, see
“RATING PLATE
INFORMATION” section.
Blower, see “OPTIONAL
BLOWER KIT
INSTALLATION” section.
Ash drawer, see “OPTIONAL
ASH DRAWER KIT” section.
EN
Brick and Baffles, see
“BRICK AND BAFFLES
INSTALLATION” section.
W415-1467 / 04.22.15
4
2.0 INTRODUCTION
EN
• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
• ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND
IS PROHIBITED.
• Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance
according to operating instructions could cause fi re or injury.
• Before installing this appliance, contact the local building or fi re authority and follow their guidelines.
• This appliance must be installed by a qualifi ed installer.
• Risk of burns. The appliance should be turned off and cooled before servicing.
• Do not operate without fully assembling all components.
• Do not let the appliance become hot enough for any part to glow red.
• Do not install damaged, incomplete or substitute components.
• Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges
may be sharp.
• Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid
burns or clothing ignition.
• Young children should be carefully supervised when they are in the same room as the appliance. Toddlers,
young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if
there are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable safety
gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
• Clothing or other fl ammable material should not be placed on or near the appliance. Objects placed in front of
the appliance must be kept a minimum of 48” (1219.2mm) away from the front face of the appliance.
• Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
• Ensure you have incorporated adequate safety measures to protect infants/toddlers from touching hot surfaces.
• Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
• Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot
surfaces. These screens and guards must be fastened to the fl oor.
• Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
• Under no circumstances should this appliance be modifi ed.
• This appliance must not be connected to a chimney fl ue pipe servicing a separate solid fuel burning appliance.
• Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should
be done by a licensed or qualifi ed service person.
• Do not strike or slam shut the appliance glass door.
• Only doors / optional fronts certifi ed with the unit are to be installed on the appliance.
• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all
plastic bags, these are not toys and should be kept away from children and infants.
• If the appliance is not properly installed, a house fi re may result. Do not expose the appliance to the elements
(ex. rain, etc.) and keep the appliance dry at all times. Wet insulation will produce an odour when the appliance
is used.
• The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as required.
• Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc.
• Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to
smoke spillage in your home.
• Lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or too
green or freshly cut hardwoods. Burning wet unseasoned wood can cause excessive creosote accumulation.
When this is ignited it can cause a chimney fi re that may result in a serious house fi re.
• This appliance is designed to burn natural wood only. Do not burn trash or garbage, lawn clippings / waste,
rubber, waste petroleum products, paints or paint thinners / solvents, plastic, materials containing asbestos,
construction debris, railroad ties or treated wood, manure or animal remains, salt water driftwood or salted
materials, unseasoned wood, coal, charcoal, coloured paper, cardboard, plywood or particleboard. Burning
these materials may result in release of toxic fumes or render the appliance ineffective and cause smoke.
• Burn wood directly on the fi rebricks. Do not elevate grate or otherwise raise the fi re.
• Do not store wood within appliance installation clearances or within the space required for re-fueling and ash
removal.
• Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away
from the home or structure until completely cool.
• Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance.
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or
damage to decorations, a T.V. or other electronic components.
* As tested using test method 28
** Figures will vary considerably with individual conditions.
*** Wolf Steel Ltd. estimated realistic BTU/hr with cordwood logs and regular refueling.
W415-1467 / 04.22.15
6
2.3 GENERAL INSTRUCTIONS
EN
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH
LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
THIS APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET. TO
REDUCE RISK OF FIRE OR PREVENT INJURY, DO NOT INSTALL A VENTED OR UNVENTED GAS LOG
BURNING YOUR UNIT WITH THE ASH DUMP DOOR OPEN OR AJAR CREATES A FIRE HAZARD THAT
MAY RESULT IN DISCOLOURATION TO THE GOLD PLATED DOOR, INTERNAL DAMAGE TO THE
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
THIS APPLIANCE AND IT’S COMPONENTS ARE DESIGNED TO BE INSTALLED AND OPERATED AS A
SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED
BY THESE INSTALLATION INSTRUCTIONS, WILL VOID THE LISTING AND MAY VOID THE PRODUCT
WARRANTY. IT MAY ALSO CREATE A HAZARDOUS INSTALLATION. READ THROUGH THESE
INSTRUCTIONS THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM
!
WARNING
THE UNITED STATES.
SET INTO THE APPLIANCE.
APPLIANCE OR A HOUSE CHIMNEY FIRE.
CAREFULLY THROUGHOUT YOUR PROJECT.
4.7
• Before beginning your installation, consult with your local building code agency or fi re offi cials and
insurance representative to ensure compliance.
• Non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke open a
window near the appliance.
• Remove any dust or debris off the top of the appliance before fi ring the appliance as the paint will
become soft as the appliance heats up and will harden as the appliance cures. To cure the paint on
your appliance burn your appliance moderately hot during the fi rst few fi res.
• To keep the gasket from sticking to the appliance as the paint is curing, periodically open the door
every 5-10 minutes.
• For the fi rst two weeks use generous amounts of fuel and burn the appliance with the damper wide
open for an hour as the appliance goes through a process of eliminating moisture in the steel and
fi rebricks. The initial heat output will be reduced while the moisture is bring drawn from the appliance
and it will be necessary to build several hot fi res to remove this moisture. DURING THIS PROCESS
DO NOT OVERFIRE THE APPLIANCE. REDUCE THE AMOUNT OF AIR COMING INTO THE
APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED.
W415-1467 / 04.22.15
2.4 GENERAL INFORMATION
HOT SECONDARY AIR
FIBRE BRICKS
REFRACTORY
2 SIDES, BACK
& BOTTOM
SECONDARY AIR
PRIMARY AIR
FLUE GLASS
CERAMIC
GLASS
AIR CONTROL
COMBUSTION AIR
INTAKE
OPEN
CLOSED
We suggest that our woodburning hearth products
be installed and serviced by professionals who are
certified in the U.S. by the National Fireplace
Institue® (NFI) as NFI Woodburning Specialists or
who are certified in Canada by
Wood Energy Technical
Training (WETT).
DO NOT OPERATE THIS APPLIANCE WITHOUT THE LEGS INSTALLED.
Y our appliance has been specifi cally designed over many months of research to meet the 1990 U.S.A. EPA particulate
emission standards and have been extensively tested in Canadian and American laboratories. This system is the most
effi cient, simple and trouble free we know and works as follows:
The chimney vent system used on your wood burning appliance should be designed with the least amount of
restriction possible to enable the exhaust products to easily fl ow through it. Chimney vent systems that are
too short or too long can also have an adverse affect on the fl ow of exhaust through it. The wood burning
appliance and chimney vent system also require a suffi cient supply of combustion air not only to support the
combustion in the combustion chamber but to replace the exhaust leaving it so it can fl ow freely up through
the vent system and out into the atmosphere. It is the correct balance of combustion air and the chimney vent
system that will ensure the appliance provides you with its optimum performance.
Combustion air enters through two holes in the bottom
covered by a single draft control. Air from the front hole
goes up on either side of the door into a preheating airwash
located across the top and then down the window to feed
the fi re and also to ensure that the glass remains clean.
Air from this hole also feeds directly into the combustion
chamber at hearth level. Secondary air from the rear hole
travels up the back in the secondary air housing to the
manifold located at the top and shoots out laterally to oxidize
the gases below the smoke exit.
!
WARNING
7
EN
The combustion chamber is lined with high temperature
fi rebrick on 2 sides, the back and across the bottom,
with a layer of fi bre baffl es at the top to maintain a high
temperature in the combustion chamber so that gases
mixing with the preheated air from the secondary air
manifold tube are easily ignited and burned. The appliance
sides and back are shielded to direct the heat upwards and forwards into the room.
Be sure to provide suffi cient combustion air. There are many other appliances in your home competing for air such as:
a kitchen range hood, forced air heating devices or a bathroom exhaust fan.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
After extended periods of non-operation such as following a vacation or a warm weather season, the appliance may
emit a slight odour for a few hours. This is caused by dust particles on the fi rebox burning off. Open a window to
suffi ciently ventilate the room.
CALIFORNIA PROP 65 WARNING:
Use of this product may produce smoke which contains
chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.
If optional ash drawer is purchased, ensure that the ash dump
door is tightly closed, allow the door to snap shut dislodging
anything (ashes or pieces of coal) that may be stuck in the opening.
If you experience smoking problems, you may been to open a door, a window or otherwise provide some method of
supplying combustion air to the appliance.
W415-1467 / 04.22.15
8
2.5 RATING PLATE LOCATION
EN
For rating plate location, see
“INSTALLATION OVERVIEW”
This illustration is for reference
only. Refer to the rating plate on the
appliance for accurate information.
INSTALL AND USE ONLY IN
ACCORDANCE WITH THE
MANUFACTURER’S
INSTRUCTIONS AND LOCAL
BUILDING CODES.
MINIMUM CEILING HEIGHT:
7FT (2.13m)
HEARTH EXTENSION /
COMBUSTIBLE FLOOR
PROTECTION: IF INSTALLED
ON A COMBUSTIBLE FLOOR,
UNIT MUST BE PLACED ON A
NON-COMBUSTIBLE FLOOR
PROTECTOR EXTENDING 18”
(455mm) IN FRONT AND 8”
(205mm) TO THE SIDES AND
BACK.
CHIMNEY TYPE: MINIMUM 6”
(152mm) DIAMETER
APPROVED RESIDENTIAL
TYPE FOR MOBILE HOME USE
A CHIMNEY LISTED TO ULC
S629 IN CANADA OR UL 103HT
IN THE USA.
CHIMNEY CONNECTOR: 6”
(152mm) DIAMETER MINIMUM
24 GAUGE STEEL MINIMUM
CLEARANCE FROM
HORIZONTAL CONNECTOR
AND CEILING 18” (455mm).
DO NOT OBSTRUCT SPACE
UNDER HEATER.
SPECIAL METHODS ARE
REQUIRED WHEN PASSING A
CHIMNEY THROUGH A WALL
OR CEILING. SEE INSTRUCTIONS AND BUILDING CODES.
DO NOT CONNECT THIS UNIT
TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
FUEL: FOR USE WITH WOOD
ONLY. DO NOT USE GRATE OR
ELEVATE FIRE. BUILD WOOD
FIRE DIRECTLY ON HEARTH.
WARNING: RISK OF SMOKE
SPILLAGE. OPERATE ONLY
WITH DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH
CERAMIC GLASS.
DO NOT OVERFIRE. IF
HEATER OR CHIMNEY
CONNECTORS GLOW, YOU
ARE OVERFIRING. INSPECT
AND CLEAN CHIMNEY
FREQUENTLY. UNDER
CERTAIN CONDITIONS OF
USE CREOSOTE BUILD-UP
MAY OCCUR RAPIDLY.
OPTIONAL BLOWER KIT:
EP-62, 115V, 60HZ, 0.82AMP.
ROUTE CORD AWAY FROM
UNIT.
DANGER: RISK OF
ELECTRICAL SHOCK.
DISCONNECT POWER
BEFORE SERVICING UNIT.
INSERT: INSTALL AND USE
ONLY IN SOLID FUEL
BURNING FIREPLACES. DO
NOT REMOVE BRICKS OR
MORTAR FROM SOLID FUEL
BURNING FIREPLACE.
INSTALL WITH A POSITIVE
FLUE CONNECTOR AND
FACEPLATE.
S4
POUR INSTALLATION ET
UTILISATION CONFORM
INSTRUCTIONS DU FABRICANT ET
AUX CODES LOCAUX DU BÂTIMENT.
HAUTEUR DE PLAFOND MINIMAL
7PI (2,13m).
PROLONGEMENT
D’ÂTRE/PROTECTION DU
PLANCHER COMBUSTIBLE: SI
INSTALL
COMBUSTIBLE, L’APPAREIL DOIT
ÊTRE PLAC
PROTECTRICE INCOMBUSTIBLE
S’ÉTENDANT SUR 18” (455mm)
L’AVANT ET 8” (205mm) À L’ARRIÈRE
ET SUR LES CÔTÉS.
TYPE DE CHIMNÉE: DIAMÈTRE
MINIMAL DE 6” (152mm)
APPROUVÉE POUR USAGE
RÉSIDENTIEL. MAISON MOBILE
EMPLOYEZ UNE CHEMINÉE
HOMOLOGUÉE ULC S629 AU
CANADA OU UL 103HT AUX
ÉTATS-UNIS.
RACCORD DE CHEMINÉE:
DIAMÈTRE DE 6” (152mm) D’ACIER
DE CALIBRE 24 MINIMUM. 18”
(455mm) DE DÉGAGEMENT MINIMAL
ENTRE LE RACCORD HORIZONTAL
ET LE PLAFOND.
NE RIEN ENTREPOSER SOUS
L’APPAREIL.
DES MÉTHODES SPÉCIALES SONT
REQUISES LORSQU’UNE CHEMINÉE
TRAVERSE UN MUR OU UN
PLAFOND. VOIR LES INSTRUCTIONS ET LES CODES DU
BÂTIMENT.
NE PAS RACCORDER À LA
CHEMINÉE D’UN AUTRE APPAREIL.
COMBUSTIBLE: POUR USAGE AVEC
LE BOIS SEULEMENT. N’UTILISEZ
PAS DE CHENET OU NE
SURÉLEVEZ PAS LE BOIS.
PRÉPAREZ LE FEU DIRECTEMENT
SUR L’ÂTRE.
AVERTISSEMENT: RISQUE
D’ÉCHAPPEMENT DE FUMÉE. TENIR
LA PORTE FERMÉE LORSQUE LE
POÊLE FONCTIONNE. REMPLACEZ
LA VITRE PAR UNE VITRE EN
CÉRAMIQUE SEULEMENT.
NE SURCHAUFFEZ PAS L’APPAREIL.
SI L’APPAREIL OU LES RACCORDS
ROUGEOIENT, L’APPAREIL
SURCHAUFEE. INSPECTEZ ET
NETTOYEZ LA CHEMINÉE
FRÉQUEMMENT. DANS CERTAINES
CONDITIONS, DES DÉPÔTS DE
CRÉOSOTE PEUVENT SE FORMER
RAPIDEMENT.
SOUFFLERIE OPTIONNELLE: EP-62,
115V, 60HZ, 0,82A. TENEZ LE
CORDON ÉLECTRIQUE LOIN DE
L’APPAREIL.
DANGER: RISQUE DE SECOUSSE
ÉLECTRIQUE. DÉBRANCHEZ AVANT
DE PROCÉDER À L’ENTRETIEN.
ENCASTRÉ: INSTALLEZ ET UTILISEZ
SEULEMENT DANS UN FOYER À
COMBUSTIBLE SOLIDE. NE RETIREZ
PAS DE MORTIER, NI BRIQUES DU
FOYER À COMBUSTIBLE SOLIDE.
INSTALLEZ AVEC UNE GAINE
CONFORME ET UNE PLAQUE DE
RECOUVREMENT.
CAUTION:
ATTENTION:
U.S. Environmental Protection Agency Certified to comply with July 1990, particulate emissions standards/
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
Certifié conforme à la norme d’ émanation de particles de juillet 1990: 40 CFR Part 60, Subpart AAA
TESTED TO: / TESTÉ SELON : UL1482 / ULC S627
MODEL / MODÈLE - EPA 1400
14001400L1402
ÉMENT AUX
CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT).
A MINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY
É SUR UN PLANCHER
É SUR UNE PLAQUE
BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR
SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS
D’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTRE
INSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNE
PRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm)
JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANT
JURIDICTION.
À
BACK WALL (M/A)
IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT
EXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18”
(455mm) TO THE FRONT.
SI LE POÊLE EST INSTALL
SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER
LES CÔTÉS ET L’AMÉRE DU POÊ
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL
CHIMNEY CONNECTOR / DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX
COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:
USING DOUBLE WALL CONNECTOR /
UTILISATION D’UN CONDUIT DE
RACCORDEMENT À DOUBLE PAROI
1400
10IN/PO (254 mm)
6IN/PO (152 mm)
4IN/PO (102 mm)
*MODELS 1400 AND S4 MAY BE INSTALLED INTO A MOBILE HOME IN THE
UNITED STATES ONLY.
*LE MODÈLES 1400 ET S4 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISON
MOBILE AUX ÉTATS-UNIS SEULEMENT .
LISTED SOLID FUEL BURNING FIREPLACE INSERT /
ENCASTRÉ À C OMBUS TIBLE SOLIDE HOMOLOGUÉ
TESTED TO / TESTÉ SELON :
ULC S628 / UL 1482
CEILING / PLAFOND
D
FLOOR / PLANCHER
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AW A Y . CONT ACT MA Y CAUSE
SKIN BURNS.
QUAND L’APPAREIL FONCTIONNE, LA SURF ACE DEVIENT
CHAUDE. NE PAS TOUCHER. TENIR LES ENF ANTS, LES
VÊTEMENTS ET LES MEUBLES À L’ÉCART . LE CONT ACT PEUT
CAUSER DES BRÛLURES À LA PEAU.
CLEARANCES TO COMBUSTIBLE CONSTRUCTION /
DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:
(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)
A SIDE FACING / CÔTÉ 1 IN/PO (25mm)*
C
B TOP FACING / DESSUS 28 IN/PO (710mm)
B
C MANTEL / TABLETTE 28 IN/PO (710mm)
A
D SIDE WALL / MUR LATÉRAL 17 IN/PO (430mm)
*CLEARA NCE TO EDGE OF FLASHING / DÉGAGEMENT AU
BORD DE LA FAÇADE
C
SIDE WALL (M/L)
LE DE 8” (200mm) ET SE PROLONGER DE 18”
16IN/PO (406 mm)
12IN/PO (305 mm)
6IN/PO (152 mm)
DATE CODE / DE DATE
1400 SERIES RATING PLATE ILLUSTRATED
1450
B"
8"
A"
ALCOVE
S4
MAISON / MOBILE HOME*
16IN/PO (406 mm)
6IN/PO (152 mm)
4IN/PO (102mm)
EPI 1402
1400C
8"
8"
18"
S4
W385-1901
W415-1467 / 04.22.15
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with
MODEL / MODÈLE: 1400
2015 particulate emissions standards. Not approved for sale after May 15,2020.
Certifié conforme à la norme d’ émanation de particles de 2015. Non approuvé
pour la vente après le 15 mai, 2020. 40 CFR Part 60, Subpart AAA. 3.5 Grams
Per Hour / 2015 Crib Wood / 3.5 Grammes par heure / Crib Wood 2015.
This wood appliance needs periodic inspection and repair for proper operation.
Consult the owner’s manual for further information. it is against federal
regulations to operate this wood appliance in a manner inconsistent with the
operating instructions in the owner’s manual. / Cet appareil au bois doit faire
l'objet d'une inspection et d'un entretien périodiques pour un fonctionnement
adéquat. Consultez le manuel d'instructions pour plus d'information. Les
règlements fédéraux interdisent d'utiliser cet appareil de chauffage d'une
manière allant à l'encontre des instructions de fonctionnement contenues dans
ce manuel.
W385-2040
3.0 PRE-INSTALLATION PREPARATION
14"
23"
ALCOVE
4 FOOT
MAX
9”6”
3.1 APPLIANCE PLACEMENT
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 48” (1219.2mm) of the front of the appliance.
3.2 CLEARANCE TO COMBUSTIBLES
!
WARNING
DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (2.1m)
(CEILING OF ENCLOSURE TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT).
SIDEWALL (A)12" (305mm)12" (305mm)10" (254mm)10" (254mm)
SIDEWALL TO FLUE (B)21 3/4" (552mm)21 3/4" (552mm)19 3/4" (502mm)19 3/4" (502mm)
BACKWALL (C)10" (254mm)12" (305mm)6"(152mm)6" (152mm)
BACKWALL TO FLUE (D)13 1/2" (343mm)16 1/2" (419mm)9 1/2" (241mm)10 1/2" (267mm)
CORNER (E)6" (152mm)6" (152mm)2" (51mm)4" (102mm)
CEILING (F)84" (2134mm)84" (2134mm)84" (2134mm)84" (2134mm)
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply
with NFPA 211 or CAN/CSA-B365.
3.3 ALCOVE INSTALLATION
1100 series only may be installed, using a listed double wall connector,
such as Security DL6 in Canada, the Simpson Duravent Plus DVL in
the USA or an equivalent double wall connector, into an alcove having
a depth of no more than 4 feet and a height of at least 7 feet.
The minimum clearances are as shown.
A
BACK WALL
SIDE WALL
E
E
F
SIDE WALL
W415-1467 / 04.22.15
10
3.4 FLOOR PROTECTION
EMBER PROTECTOR:
EN
This appliance must be installed on a non-combustible protector that extends to the front, sides and back of the
appliance as per the minimum requirements below.
NOTE: Ember protection is required for spark and ash shielding, not for limiting fl oor temperatures
from the radiant heat of the appliance. The appliance was designed and safety tested so that without
any protection, the fl oor will not overheat.
L
J
3.5 OUTSIDE AIR
IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING APPLI-
The following are signs that a outside air kit may be required:
• When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
• In the winter there is too much condensation on the windows.
• Opening a window seems to alleviate the above symptoms.
• A ventilation system is installed in the house.
• Other devices are present that exhaust house air.
• The house has tight fi tting windows and/or is equipped with a
A. Connection from the appliance’s air intake to the outside is
B. Use a fresh air kit. Secure the aluminum liner by fl aring the end
C. Attach the rear knockout plate (located inside the ash pan for shipping purposes).
chimney does not draw steadily.
well-sealed vapour barrier.
mandatory in mobile homes only, either through a hole in the
wall or through the hole in the fl oor to line up with the knock out
in the leg model or the hole in the pedestal base.
once it is inserted through the hole in the base of the leg or
pedestal model. If the air intake is through the fl oor, the hole in the pedestal back must be covered with
sheet metal to avoid cold air spillage into the room. A cover plate is available from your Wolf Steel Ltd.
dealer. Avoid cutting away fl oor joists, wall studs, electrical wires or plumbing. Seal around the outside
pipe with insulation to prevent drafts.
W415-1467 / 04.22.15
3.6 MOBILE HOME
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE
THE APPLIANCE MUST BE PROVIDED WITH OUTSIDE COMBUSTION AIR.
USE A CHIMNEY CERTIFIED FOR WOOD BURNING UL 103 S629, TYPE HT (2100°F).
MODEL 1100ML, 1100C, 1400ML, and 1400C ARE APPROVED FOR INSTALLATION IN MOBILE HOMES
IN THE UNITED STATES ONLY.
!
WARNING
DO NOT INSTALL IN SLEEPING ROOM.
MAINTAINED.
THE APPLIANCE MUST BE BOLTED TO THE FLOOR.
INSTALL ACCORDING TO 24 CFR, PART 3280 (HUD).
11
EN
For specifi c clearances, see “MINIMUM
CLEARANCES TO COMBUSTIBLES” section.
The appliance must be installed between ceiling
joists, with radiation shield and roof fl ashing, so that
the structural strength, insulation and waterproof
qualities of the home are not lessened. Seal with
silicone to maintain a vapour barrier at the chimney
and outside air pipe penetrations.
This model is equipped with holes so that the
appliance can be bolted securely to the fl oor.
RAIN CAP
MOBILE HOME
ROOF FLASHING
RADIATION SHIELD
CEILING SUPPORT
TRIM COLLAR
APPLIANCE
BOL TED T O FLOOR
HEARTH PAD
OUTSIDE AIR CONNECTION
THROUGH WALL OR FLOOR
REMOVE TO
ALLOW FOR
TRANSPORATION
W415-1467 / 04.22.15
12
4.0 INSTALLATION
EN
CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE
APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE
APPLIANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES ARE HAZARDOUS.
DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN FROM ATTIC SPACES, BASEMENTS OR
ABOVE THE ROOFING WHERE OTHER HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR.
THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL. THE
OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES, DEBRIS ICE AND/OR SNOW. IT MUST BE UNRESTRICTED WHILE
APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE AND AN INABILITY
TO MAINTAIN A FIRE. SMOKE SPILLAGE CAN ALSO SET OFF SMOKE ALARMS.
NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE APPLIANCE MUST NOT BE INSTALLED
AGAINST VAPOUR BARRIERS OR EXPOSED INSULATION. LOCALIZED OVERHEATING COULD OCCUR AND A FIRE
!
WARNING
WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION.
COULD RESULT.
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT AIR, GRILLE OR
LOUVRE OPENINGS. DO NOT ADD A HOOD.
KEEP HAND TOOLS IN GOOD CONDITION, SHARPEN CUTTING EDGES AND MAKE SURE TOOL HANDLES ARE
SECURE.
ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO THE ENCLOSURE TO PREVENT FIRES.
68.3A
W415-1467 / 04.22.15
4.1 CHIMNEY
NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE. THE HIGHER
TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO COMBUSTIBLE
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE.
TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING THE
PROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE. TO
PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE WEATHER, WE
RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST-RESISTANT PAINT.
DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHER MATERIAL.
INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO OVERHEAT.
MAINTAIN A MINIMUM 2" AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT ALL TIMES.
FAILURE TO MAINTAIN THIS 2" AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE. NEVER FILL THIS
DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIAL
!
WARNING
CHASE MATERIALS TO CAUSE A FIRE.
SPACE WITH ANY TYPE OF MATERIAL.
TO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED.
13
EN
FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOOR AREA.
THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT
ABOVE THE STOVE. ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS A MINIMUM
OF 1/4” PER FOOT AND ALL CONNECTIONS MUST BE TIGHT AND SECURED BY THREE SHEET
METAL SCREWS EQUALLY SPACED. AN UNINSULATED SMOKE PIPE SHALL NOT PASS THROUGH
AN ATTIC, ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR THROUGH A FLOOR,
CEILING, WALL OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTIONS.
DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION.
Your appliance may be hooked up with a factory built or masonry chimney. If you are using a factory
built chimney, it must comply with ULCS629 (Canada) or UL103 (USA) standards. It must therefore be
a 6" (152mm) HT Type (2100°F) chimney. It is extremely important that it be installed according to the
manufacturer's specifi cations. The manufacturer's installation instructions and specifi ed clearances should
always be followed in accordance with local and national codes. In Canada the CSA B365 and the CSA C22.1
installation codes are to be followed. In the USA the ANSI NFPA 70 and ANSI NFPA 211 installation codes are
to be followed.
Chimney and chimney connector must be in good condition and kept clean.
W415-1467 / 04.22.15
14
A
4.1.1 CHIMNEY CONNECTION
Your chimney connector and chimney must have the same diameter as the appliance’s exhaust fl ue outlet. The
EN
appliance pipe must be made of aluminized or cold roll steel with a minimum 24 gauge thickness. It is strictly
forbidden to use galvanized steel.
A 6” (152mm) diameter single wall chimney connector, used to connect the appliance to the chimney, must be
installed with the crimped end toward the appliance. This will ensure that the moisture which condenses from the
burning wood will fl ow back into the fi re chamber. Each joint in the chimney connector must be secured with at least
three sheet metal screws.
For installation of your chimney connector, the following recommendations may be useful.
• The chimney connector must be short and straight. For optimum performance it is recommended that
all horizontal runs have a minimum 1/4” (6mm) rise per foot, with the upper end of the section toward
the chimney. For safe and proper operation of the appliance, see “INSTALLATION” instructions.
• To insure a good draft, the total horizontal length of the connector should never exceed 8' to 10' (2m to
3m). In the case of vertical installation, the total length of the connector can be longer and connected
without problem to the chimney at the ceiling level.
• There should never be more than two 90° elbows in the entire connector and chimney system. Never
start with a 90° elbow. Always go up vertically for at least 2 feet (0.6m) from the fl ue collar before using
a 90° elbow.
• The connector must not pass through any combustible material, nor may it pass through a concealed
space (such as an attic, roof space, or closet). If passing through a wall, ceiling, or into a masonry
chimney, use either chimney components listed for that specifi c use, or means acceptable to local
authorities having jurisdiction over the installation.
This appliance must be connected to:
. A chimney complying with the requirements for
Type HT chimneys in the Standard for Chimneys,
Factory-Built, Residential Type and Building Heating
Appliance, or
MALE END OF
B.A code-approved masonry chimney with a fl ue
liner. Vent the stove into a masonry chimney or an
approved, insulated solid-fuel stainless-steel chimney
with as short and straight a length of 6” (152.4mm)
diameter chimney connector as possible. Connection
to a masonry chimney must be by a metal or masonry
thimble cemented in place.
TOWARD
APPLIANCE
58.1B
CONNECTOR
OR CHIMNEY
PIPE
FLUE GAS
DIRECTION
W415-1467 / 04.22.15
4.1.2 ADDING SECTIONS
A
dd chimney sections, according to the manufacturers installation instructions. The chimney must extend at
least, 3 feet (1m) above its point of contact with the roof and at least 2 feet (0.6m) higher than any wall, roof,
building or obstacle within 10 feet (3m) horizontally.
15
EN
LESS THAN
10 FEET
(3m)
2 FT (0.6m)
MIN
3 FT (1m)
MIN
3 FT
(1m)
MIN
2 FT (0.6m) MIN
10 FT (3m)
TO NEAREST
ROOFLINE
RIDGE
LESS THAN
10 FT (3m)
10 FEET
(3m)
OR MORE
3 FT (1m)
3 FT (1m)
MIN
2 FT (0.6m)
MIN
MIN
FLAT ROOF
WALL
59.1B
W415-1467 / 04.22.15
16
4.1.3 TYPICAL THROUGH THE CEILING
A. Move the stove into position with the fl ue centered, midpoint between two
EN
B. Cut and frame an opening in the ceiling to provide a 2” (50.8mm) clearance
Nail headers between the joist for extra support.
joists to prevent having to cut them. Use a plumb bob to line up the center.
between the outside of the chimney and any combustible material. DO NOT
FILL THIS SPACE WITH ANY TYPE OF MATERIAL.
Firestop spacers must be placed on the
bottom of each framed opening in any fl oor
or ceiling that the chimney passes through.
If your chimney system is enclosed within
the attic area, a rafter radiation shield is
required.
HEADERS
C.Hold a plumb bob from the underside of
the roof to determine where the opening in
FIRESTOP SPACER UNDERSIDE OF JOIST
the roof should be. Cut and frame the roof
opening to maintain proper 2” (50.8mm) clearances.
NOTE: The chimney must be supported at the ceiling or roof so that it’s
weight does not rest on the appliance and must comply with it’s
manufacturer’s instructions.
LISTED
CHIMNEY
CEILING
SUPPORT
TO STOVE
SPECIFIED
CLEARANCE
MAINTAIN
2” (50.8mm)
CLEARANCE
LISTED CHIMNEY
CHIMNEY
SUPPORT
TERMINAL
STORM
COLLAR
FLASHING
ROOF
INSULATION
W415-1467 / 04.22.15
FLOOR
PROTECTOR
CHIMNEY
CONNECTOR
COMBUSTIBLE
WALL
60.1B
4.1.4 TYPICAL THROUGH THE WALL
If possible, design the installation so that the connector does not pass through a combustible wall. If during
your installation you must pass through a combustible wall, check with your building inspector before you
begin. Also check with the chimney connector manufacturer for any specifi c requirements.
Consult with your dealer regarding special connection components available for use for wall pass-throughs.
Use only parts that have been tested and listed for use in a wall pass-through.
COMBUSTIBLE
OUTSIDE WALL
LISTED
CHIMNEY
2” (50.8mm)
CLEARANCE
INSULATED
“T”
WALL
SUPPORT
WALL
CHIMNEY
TO
STOVE
THIMBLE
SECTION
LISTED
PIPE
WALL SPACER
FOR OUTSIDE
ROOF
COMBUSTIBLE
(50.8mm) CLEARANCE
THROUGH EAVE
CEILING
MAINTAIN 2”
17
EN
TERMINAL
STORM
COLLAR
FLASHING
CHIMNEY
CONNECTOR
FLOOR
PROTECTOR
COMBUSTIBLE
WALL
61.1A
W415-1467 / 04.22.15
18
FLOOR
PROTECTOR
CHIMNEY
CONNECTOR
COMBUSTIBLE
WALL
CLEARANCE
EAVE
RAFTER
CLEARANCE WITH FIRESTOP
CEILING JOIST
THIMBLE
4.1.5 TYPICAL EXISTING MASONRY
You can also install your appliance using your
EN
existing masonry chimney. To do so, follow the
guidelines below. Use a factory-built thimble,
or construct your own brick thimble. If you are
using a masonry chimney, it is important that it
be built in compliance with the specifi cations
of the Building Code in your region. It must
normally be lined with fi re clay bricks, metal
or clay tiles sealed together with fi re cement.
(Round fl ues are the most effi cient). The
maximum fl ue size is 8” (203.2mm) x 8”
(203.2mm) square or 6” (152.4mm) round.
For greater diameters it is necessary to
install a 6” stainless steel liner.
62.1A
W415-1467 / 04.22.15
5.0 FINISHING
5.1 LEG INSTALLATION (1100ML / 1400ML)
To avoid being damaged during shipping, the appliance has been bolted to the pallet
and must be unbolted before the appliance can be installed.
A. Remove the 4 nuts and washers from
the underside of the pallet.
B. Lift the appliance up and away from
the pallet to clear the threaded studs
sticking through the pallet. Place
the appliance on its back onto a
protective surface such as a carpet or
blanket to avoid scratches during leg
installation.
C. Remove the four additional nuts from
each of the four studs.
D. Use four of the nuts and washers removed above to install the legs as illustrated.
E. Lift the appliance up and gently set down on all four legs. Do not pivot appliance up on its legs, as this
could result in damage to the legs.
19
EN
5.2 DOOR REMOVAL / INSTALLATION (1100ML / 1400ML)
A. Pivot the door open and lift up to clear the
bushings. Do not pivot the door any further than
necessary.
B. Carefully set the door aside and pull the pins out
from the door bushings. Repeat in reverse order to
install the door.
5.3 1100C/1400C DOOR REMOVAL / INSTALLATION
A. 1400C only: Remove the cast lid.
B. Remove cast top.
C. Pull pin from top door hinge. It is important to hold the door while
removing the pin. Pivot the door to clear the top door hinge. Lift the door
off of the lower pin. Do not pivot the door any further than necessary.
Repeat in reverse order to install the door.
PINS
DOOR ADJUSTMENT: Loosen screws of top door bracket and slide side to side
to adjust the door hinge. Close door against paper seal to ensure proper door
seal.
W415-1467 / 04.22.15
20
5.4 1400C CAST LID LEVELLING
A. Loosen the clinching nut. (4 places)
EN
B.Tighten or loosen the levelling screw
in the adjusting nut.
C.Tighten the clinching nut.
5.5 DOOR HANDLE INSTALLATION
BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT
MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE.
LEVELLING
SCREW
ADJUSTING
NUT
HINGE
BRACKET
CAST TOP
CLINCHING
NUT
!
WARNING
DO NOT STRIKE OR SLAM DOOR.
NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT.
NOTE: DOOR MAY NOT BE AS
ILLUSTRATED
FRONT VIEW
DOOR
DOOR
HANDLE
SPRING
WASHER
DOOR HANDLE
LATCH
SPACER
LOCK
WASHER
NUT
W415-1467 / 04.22.15
NOTE: Position of
door handle latch.
98.1
5.6 BRICKS AND BAFFLES INSTALLATION
!
WARNING
OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERA-
TURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE.
With appliance and chimney installation completed, move the bricks into place for your appliance as
previously illustrated.
A. Install fi ve (1100ML) or six (1400ML) bricks along both sides of the appliance. Before installing the
back bricks, loosen the screw holding the retainer and ensure that it has been moved forward. Install
the six bricks along the back wall by pivoting the bricks up under the brick retainer. Retighten the
screw. NOTE: Center bricks have been cut.
B. Carefully pivot fi bre baffl e up onto the top of the side brick. Slide it over onto the fl ange of the manifold.
Ensure that the top baffl es are pushed all the way to the rear of the fi rebox, leaving a minimum of a 1”
(25mm) gap along the front. This will allow the fl ue gases to escape the fi rebox.
C. Install the bottom bricks, working from the back of the appliance forward.
D. Install the 4 bricks along the front.
NOTE: Do not operate if baffl e and manifold shield are not in position.
1100ML/1100C & 1400ML/1400C (All Firebricks are 1 1/4” (32mm) Thick)
21
EN
FIREBRICK
DIMENSIONS
A
B
C
D
E
4 1/2” x 9”
(114mm x 229mm)
3” x 9” (Molded)
(6mm x 229mm)
4 1/2” x 4 1/2”
(114mm x 144mm)
3” x 9”
(76mm x 229mm)
4 1/2” x 9”
(Notched)
(114mm x 229mm)
A
C
A
A
A
G
B
PART #
1100ML/1100C 1400ML/1400C1100ML/1100C1400ML/1400C
W090-0001
X15
W090-0002
X2
W090-0003
X2
W090-0166
X2
W090-0207X1W090-0207
1100ML/1100C1400ML/1400C
E
F
AAA
D
A
A
I
A
H
B
A
A
D
J
BRICK
RETAINERS
C
A
W090-0001
X21
W090-000
X2
N/A
W090-0166
X2
X1
(Fibre Baes)
W018-0077 X2
K
K
K
NOTE: BRICKS
E & F ARE
NOTCHED AT
REAR.
E
F
FIREBRICK
DIMENSIONS
4 1/2” x 9”
F
G
H
I
J
(Notched)
(114mm x 229mm)
2 1/4” x 9”
(57mm x 229mm)
2 1/4” x 6 1/8”
(64mm x 121mm)
2 1/2” x 4 1/2”
(64mm x 114mm)
1 1/2” x 4 1/2”
(38mm x 114mm)
G
W090-0208
A
A
A
A
A
A
B
A
A
A
H
B
X1
W090-0018
X1
W090-0019
X1
W090-0016
X1
W090-0017
X1
E
A
A
D
D
A
I
J
A
PART #
F
A
A
K
K
K
W090-0208
X1
W090-0018
X1
W090-0019
X1
W090-0016
X1
W090-0017
X1
BRICK
RETAINERS
(Fibre Baes)
W018-0078 X2
A
A
A
W415-1467 / 04.22.15
22
6.0 OPTIONAL KIT INSTALLATIONS
6.1 OPTIONAL BLOWER INSTALLATION
EN
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
CONTACT WITH MOVING OR HOT OBJECTS.
Drywall dust will penetrate into the blower bearings,
causing irreparable damage. Care must be taken to
prevent drywall dust from coming into contact with
the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.
Use of the blower increases the output of heat.
51.5
MOUNTING
BRACKET
NOTE: If the optional blower (EP62-1) is installed, the blower guard (W320-0011) must
be installed. This guard is available from your
Napoleon dealer.
Attach the mounting bracket to the blower assembly. Then attach the mounting bracket to the
back of your appliance, push on the variable speed
knob and plug into any grounded electrical outlet.
See “BLOWER INSTALLATION” leafl et for detailed
instructions.
6.2 OPTIONAL ASH DRAWER (1100ML/1400ML ONLY)
!
WARNING
IMPROPER DISPOSAL OF ASHES RESULT IN FIRES. DO NOT DISCARD ASHES IN CARDBOARD
IF USING A VACUUM TO CLEAN UP ASHES, BE SURE THE ASHES ARE ENTIRELY COOLED. USING
A VACUUM TO CLEAN UP WARM ASHES COULD CAUSE A FIRE INSIDE THE VACUUM.
NEVER OPERATE YOUR APPLIANCE WITH THE ASH PLUG (IF APPLICABLE) REMOVED.
FAILURE TO ACHIEVE A GOOD SEAL BETWEEN THE ASH OPENING, ASH PLUG OR ASH WELL DOOR
WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE APPLIANCE.
BOXES, DUMP IN BACK YARDS, OR STORE IN GARAGES.
BLOWER
ASSEMBLY
VARIABLE
SPEED
SWITCH
BLOWER GUARD
Provisions have been made on the appliance to
install an optional ash drawer kit.
The EPAD-KT kit allows for convenient removal
of excess ash. This kit can be purchased through
your authorized dealer / distributor.
W415-1467 / 04.22.15
Loading...