
R
333 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
For Technical Service, (800) 645-9440
© NAPCO 2005
NP- 4CC615DCUL
4 CAMERA 6-15VDC
POWER SUPPLY
WI1332A 12/05
POWER SUPPLY DESCRIPTION
The NP- 4CC615DCUL CCTV Power Supply contains
four (4) individually fused outputs for powering video accessories such as CCTV Cameras, etc. The NP4CC615DCUL CCTV Power Supply provides 6-15VDC
distributed via four fused outputs with a total of up to 2.5A
continuous supply current.
FEATURES
• Listed (UL 2044)
Input:
• Input 24VAC 40VA or 24VAC 50VA, UL Listed Plug-in
transformer.
Output:
• 6 to 15 VDC field adjustable.
Transformer
Output current
5.5 to 12VDC
24VAC, 40VA 2.25 Amps 1.8 Amps
24VAC, 50VA 2.5 Amps 2 Amps
Fuse Ratings:
• Output fuses are rated at 1.0 Amps
Visual Indicators:
• AC input and DC output LED indicators.
Additional Features
:
• Power ON/OFF switch.
• Spare fuses included.
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates costly
labor.
Enclosure Dimensions:
115mm(H) x 220mm(W) x 250mm(D)
Output current
12 - 15VDC
INSTALLATION INSTRUCTIONS
1. Mount the NP- 4CC615DCUL in desired location.
2. Connect 24VAC 40VA or 50VA UL listed, class 2,
plug-in transformer to terminals marked [X`FMR].
3. Adjust output voltage using trim pot on the board prior
to connecting CCTV devices.
4. Switch SW1 to OFF position.
5. Connect each DC CCTV cameras to terminal marked
[+ OUT1 - to + OUT4 -] carefully observing correct
polarity. Note: It is important to measure output voltage before connecting devices to help avoid potential
damage.
CAUTION: Determine the maximum operating
voltage of the equipment being powered before
adjusting the output voltage.
6. Switch SW1 (see image above) to ON position.
7. Green LED will illuminate when unit is powered.
8. Upon completion of wiring, secure enclosure door
with catch.
WARNING: To reduce the risk of fire or electric
shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all
local codes and in accordance with the National
Electrical Code.
Terminal Identification
Terminal
Legend
X`FMR Low voltage AC input (24VAC 40VA or 50VA) from UL
+ OUT1 ---
through
+ OUT4 ---
listed, class 2 plug-in transformers.
Positive and Negative adjustable DC outputs.
Up to (12VDC - 2.5 Amps total continuous output), 1215VDC 2 Amps total continuous output.
Function/Description