NAPCO NP-4CC615DCUL Instructions Manual

R
333 Bayview Avenue
Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440
© NAPCO 2005
NP- 4CC615DCUL
4 CAMERA 6-15VDC
POWER SUPPLY
WI1332A 12/05
POWER SUPPLY DESCRIPTION
The NP- 4CC615DCUL CCTV Power Supply contains four (4) individually fused outputs for powering video ac­cessories such as CCTV Cameras, etc. The NP­4CC615DCUL CCTV Power Supply provides 6-15VDC distributed via four fused outputs with a total of up to 2.5A continuous supply current.
FEATURES
Listed (UL 2044)
Input:
Input 24VAC 40VA or 24VAC 50VA, UL Listed Plug-in
transformer.
Output:
6 to 15 VDC field adjustable.
Transformer
Output current
5.5 to 12VDC
24VAC, 40VA 2.25 Amps 1.8 Amps 24VAC, 50VA 2.5 Amps 2 Amps
Fuse Ratings:
Output fuses are rated at 1.0 Amps
Visual Indicators:
AC input and DC output LED indicators.
Additional Features
:
Power ON/OFF switch.
Spare fuses included.
Unit maintains camera synchronization.
Ease of installation saves time and eliminates costly
labor.
Enclosure Dimensions:
115mm(H) x 220mm(W) x 250mm(D)
Output current
12 - 15VDC
INSTALLATION INSTRUCTIONS
1. Mount the NP- 4CC615DCUL in desired location.
2. Connect 24VAC 40VA or 50VA UL listed, class 2, plug-in transformer to terminals marked [X`FMR].
3. Adjust output voltage using trim pot on the board prior to connecting CCTV devices.
4. Switch SW1 to OFF position.
5. Connect each DC CCTV cameras to terminal marked [+ OUT1 - to + OUT4 -] carefully observing correct polarity. Note: It is important to measure output volt­age before connecting devices to help avoid potential damage.
CAUTION: Determine the maximum operating
voltage of the equipment being powered before adjusting the output voltage.
6. Switch SW1 (see image above) to ON position.
7. Green LED will illuminate when unit is powered.
8. Upon completion of wiring, secure enclosure door with catch.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or mois­ture. This installation should be made by quali­fied service personnel and should conform to all local codes and in accordance with the National Electrical Code.
Terminal Identification
Terminal
Legend
X`FMR Low voltage AC input (24VAC 40VA or 50VA) from UL
+ OUT1 ---
through
+ OUT4 ---
listed, class 2 plug-in transformers.
Positive and Negative adjustable DC outputs. Up to (12VDC - 2.5 Amps total continuous output), 12­15VDC 2 Amps total continuous output.
Function/Description
Enclosure Dimensions
Loading...