Napco NETLINK DATASHEET

Get security staff on the scene faster with
NetLink online alarm reporting at a standard PC,
plus dramatically reduce T1 phone line costs.
In an emergency every minute counts …
NAPCO NetLink intranet/internet alarm reporting puts campus, retail or private security staff directly online with their security system using their standard PC. Receiving pinpointed alarm reports as they happen enables faster dispatches. Plus, using the internet or their own intranet instead of phone lines for alarm reporting can save thousands of dollars in traditional T1 phone line costs.
Transform a security office’s standard PC into an onsite monitoring
receiver using campus or retail intranet
Uniquely, NO dedicated central station receiver required; uses
Napco NetLink CS Software Application – ideal in a guard station
Saves thousands in budget dollars on phoneline charges
Use for primary and/or backup reporting of alarms over a TCIP/
IP based network and/or telephone lines (telco)
Security system with NetLink module sends encrypted alarm data
(alarms, status, supervisories) through TCP/IP network, securely with dynamic IP addressing.
Allows high-speed downloading via campus LAN ;
supports network-based automation routines
The NAPCO NetLink System enables Napco Gemini GEM-P816, 1632, 3200, 9600 and X255 Hybrid Panels to report alarms and status over the Internet or a local intranet (providing primary or backup reporting), using a programmable NetLink Panel Module and Windows-based NetLink Software (NL-CSRCV) on a standard PC (no dedicated central station receiver required).
With NetLink Software (NL-CSRCV) the standard PC is virtually transformed into a remote monitoring receiver, eliminating new equipment costs and saving maintenance costs on old, proprietary receivers. The PC securely receives encrypted alarm data sent from the NetLink Panel Module thru a TCP/IP network. Plus, NetLink Software supervises each NetLink Module, receives alarms and easily enables a security office, for example, to view alarms in real time, as well as reviewing event history (openings/closings) and managing data by account. The software can also be used to route events to an automation system. Furthermore, Napco Panels’ PCD-Quickloader Software can support panel program downloading through the intranet or a corporate WAN, in addition to the uploading of logs
and other data.
Manufacturing great security products is all we do. It’s that simple.
PRELIMINARY SPECIFICATIONS:
SYSTEM REQUIREMENTS:
NETLINK PANEL MODULE (NL-MOD):
The PC-configurable NAPCO NetLink™ NL-MOD enables reporting of alarms over a TCP/IP based (Intranet or Internet) network. Alarm reporting, previously via telephone lines/ telco only, can now be communicated over both a TCP/IP network and/or Telco, or via the TCP/IP network as a backup. The NL-MOD module is connected to the on-board serial port of the GEM-X255, GEM­P3200 and GEM-P9600 NAPCO GEMINI Control Panel, or is connected via the bell and PGM wires from the GEM-P1632, GEM-P816, NAPCO Express and other control panels.
NetLink Central Station Receiver Application (NL-CSRCV) The NetLink Software, NL-CSRCV, is a Windows-based application that is designed to act as a remote monitoring receiver. In place of receiving alarm data through a telephone line, the NL-CSRCV application receives encrypted alarm data sent from the NL-MOD through a TCP/IP network. The NL-CSRCV software can supervise each NL-MOD, receive alarms, provide a means of maintaining accounts and provide a means of displaying alarms and event history (opening/ closing, etc.). The NL-CSRCV could be used to display alarm events locally or can be used to route events to an automation system. For more information, see the NL-CSRCV User Guide OI294.
System Hardware Requirements:
Compatible Gemini Control Panels GEM-X255, GEM-P3200
and GEM-P9600; GEM-P1632, GEM-P816 (check WI for exact firmware version)
Standard 6 conductor modular RJ12 Cable, 1 foot in length
(provided). Required for full zone reporting/downloading.
Access to the local area network.
A standard CAT5 network cable for connection to the LAN
PC Requirements for Software (NL-CSRCV):
Windows® XP Professional installed on a dedicated PC
Intel® Pentium® 4 (2GHz processor or faster) with at least
512 MB RAM.
Hard drive space 20GB or higher.
NAPCO Tested and certified using a Dell™ Dimension™
Series 2400 & 4400 PC. (For other models, contact Napco Technical Support.)
Network Card requirements: 100 BaseT Ethernet.
Note: Not supported - Hyper-Threading technology, Dual Processors and Windows® XP Themes.
ORDERING INFORMATION:
NL-MOD NetLink Panel Module NL-CSRCV Central Station Receiver Application Software for
use in standard PC. NL-CSRCV/PC Above, preinstalled and configured in turnkey computer system. (Call for PC specs or special requirements.) NL-MODCONFIG Download software utility for initially programming/configuring Panel Module. PCD-WINDOWS Napco Panel Up/Downloading Software (version 4.4 or greater)
NL-MOD SPECIFICATIONS:
Dimensions: 1 1/2” x 7” x 4 3/4” (HxWxD) Input Voltage: 13.0-10.0VDC. Input Current: Maximum current (@8 VDC) = 100mA,nominal
current (@12VDC) = 80mA (supplied by control panel connections). Available panel combined auxiliary current is reduced by 100mA. Outputs: PGM-style open collector (negative trigger) with a maximum sink current of 50mA.
333 Bayview Avenue, Amityville, New York 11701 USA 1-800-645-9445 www.napcosecurity.com
Preliminary specifications, subject to change. Gemini, NetLink and Quickloader are trademarks of NAPCO. Windows, Dell, Intel and Pentium are trademarks of their respective companies. © NAPCO, 9/04 A482