iBridge® Touch Screen Tablet Keypad
Installation and Mounting Instructions
WI1944E 06/13
GENERAL DESCRIPTION
Napco's IBR-ITAB iBridge® touch screen tablet keypad is a highresolution LCD android tablet that
provides wireless access to all the
features of your alarm system.
The IBR-ITAB keypad is simple to
use, with its intuitive menu-driven
icons and prompts to help guide
you. The wall docking station provides charging to the IBR-ITAB's
internal battery (its integral charg-
IBR-ITAB Wireless
Touchscreen Tablet
ing circuit ensures automatic recharging as required). The décor-neutral IBR-ITABSTAND angled tabletop stand and docking station provides charging and
convenient desktop usage, is ideal for bedrooms, kitchens, etc.
FEATURES
The IBR-ITAB keypad has many convenient features:
• Touch screen control of security system--and more--from
anywhere in the home
• Easy on/off magnetic wall mounting frame (IBR-ITABSTAND
angled tabletop stand and docking station also available)
• Integrated IP video viewing of iSee Video cameras
• Message Minder recordable voice messages
• Internet browser-enabled
• Handy on-screen tools including weather, calculator, etc.
• High-speed, powerful processor
• Large high-resolution 800 x 480 pixel display for clarity
• Intuitive touch screen display with icons and menu driven
prompts (English only)
• 802.11 Wireless Wi-Fi Connectivity
• Digital picture frame or slideshow through a standard USB
memory stick / thumb drive
• Family Message Center - Record and playback messages for
family members Over two minutes of recordable time
• Entry/Exit countdown displayed
• Add or delete User Codes
• Quickly and easily bypass zones
• The IBR-ITAB Tablet Keypad is one part of the integrated
Napco iBridge
• Virtual Keypad
• Z-Wave
• Integrated iSee Video
Compatible with the following control panels:
• Freedom F-64
• LIBRA-P432EX
• GEM-P816
• GEM-P1632
• GEM-P1664
• GEM-P3200
• GEM-P9600
• GEM-X255
®
Remote Control Services that include:
®
Home Controls
Note: A standard wired keypad must be installed and enrolled
in the system before adding a IBR-ITAB keypad. Visit www.
napcosecurity.com for ordering information and evaluated Z-
Wave devices.
KEYPAD SPECIFICATIONS
Electrical Ratings
Battery: Integral Polymer Lithium-ion
Capacity: 1800mAh, 5-6 hours per charge
Speaker: 1 Integral 2W
Charger: 12VDC/2A DC Adapter, cable length 70" (180cm)
Electrical Ratings (Fully Discharged Battery)
Screen on, charging idle: 12VDC, 845mA
Clicking menu items: 12VDC, 945mA
Electrical Ratings (Fully Charged Battery)
Screen on, charging idle: 12VDC, 300mA
Clicking menu items: 12VDC, 380mA
Features
Hardware Platform: ARM11™ processor family
CPU: Samsung™ 65nm S3C6410 Mobile Processor CPU
1200MHz (up to 1.2GHz)
Frequency: 667-800MHz
RAM: 256MB DDR
ROM Flash: 1GB
Wi-Fi: 802.11b/g with built in Antenna
LCD Size: 7 inch digital screen
Resolution Ratio: 800 x 480 x 32 WVGA, 16:9 Wide Screen,
Color
Pixels: 260,000 million
Touch Screen: Digital and full-screen, Resistance
Microphone: Integral high sensitivity, voice input
External Card: Push-push type Micro SD Port, Max 32GB
USB Host Cable: USB A Female, for Mouse, keyboard HUB,
etc.
Video: Composite Video, 3.5mm to RCA Port
Firmware: Google Android 1.6
Audio: Compatible with WMA, MP3, WAV, AAC
Images: JPG (Max 2048x2048 pixels) with Slide Show
Video: MPEG-4/H.263/H.264
Housing
Dimensions (HxWxD): 7.5" x 4.7" x 0.4" (19cm x 12cmm x
10cm)
Weight: 11.6oz (330g)
Operating Temperature: 0-49ºC (32-120°F)
SELECTING THE MOUNTING LOCATION
Two items must be considered when planning the system layout:
1. The mounting location selected for the IBR-ITAB keypad
must permit a continuous wireless connection between the
IBR-ITAB keypad and the IBR-WIFI-MOD (see WI1942) or
the ISEE-WAP (see WI2049).
2. In addition, the wall-mounted Charging Station requires
1
power supplied from two wires intended to be hidden within
the mounting surface. These two wires are connected to a
power supply that can be plugged into any standard
120VAC outlet, such as in a basement or other distant location. Note: Power wires are polarized, and MUST be in-
stalled as detailed in the installation instructions that follow.
To ensure a continuous wireless connection between the IBRITAB keypad and the IBR-WIFI-MOD or ISEE-WAP, select a location for the Charging Station that is within a reasonable distance from the IBR-WIFI-MOD or ISEE-WAP. Choose a location
as high above ground level as practical, keeping in mind that
metal objects may adversely affect reception. Although wood and
wallboard construction will have little effect upon signal strength,
concrete or brick can reduce signal strength by up to 35%, while
steel-reinforced concrete or metal lath and plaster can reduce signal strength as much as 90%.
Mount the IBR-ITAB keypad Charging Station indoors only, and
avoid high condensation areas such as bathrooms. Avoid mounting in locations where direct sunlight or bright light shines directly
on the screen.
CHARGING STATION INSTALLATION
HOLLOW WALL
If installing into a 3-gang box, see instructions to the right. To
secure the Wall Mounting Plate directly to a hollow dry wall or
similar surface, proceed as follows:
1. Select the mounting location preferably at eye level for easy
viewing by the user. Select a mounting location that allows
the power wires to be hidden within the mounting surface.
Furthermore, in the image below, note how the "Wire Hole in
Wall Mounting Plate" aligns with the "Wire Hole in Mounting
Surface". The two power wires are connected to the power
supply that is plugged into any standard 120VAC outlet located in a basement or other distant location. IMPORTANT:
The positive power supply wire is marked with red heat
shrink tubing; be sure not to dislodge this red marking when
routing wires, as polarity MUST be maintained.
(HW1854)
Finishin g
Cover
Plate
2. With the final mounting location selected, drill the power wire
hole in the mounting surface. Snake the two power wires
from the power supply source location into the interior of the
mounting surface (wall), then out through the power wire
hole drilled in the mounting surface.
3. Using wire nuts or connectors appropriate for the installation,
connect the red wire from the Wall Mounting Plate to the
2
(SC461) #6 x 1" long
sheet metal Phillips
flat head Type A
screws (6)*
Hollow Wall Installations
"Wire Hole
in Wall
Mounting
Plate"
(9HW1836ASSY)
Wall Mounting
Plate
"Wire
Hole in
Mounting
Surface"
positive power supply wire marked with the red heat shrink
tubing. Connect the black wire from the Wall Mounting Plate
to the other black power supply wire. If the red heat shrink
tubing was dislodged and you are uncertain as to the polarity, use a voltmeter to determine the polarity. Push wires
into the power wire hole in the mounting surface, leaving the
Wall Mounting Plate flush against the mounting surface.
4. Use the Wall Mounting Plate as a template, marking the 6
screw holes with a pencil.
5. Drill 6 holes 3/16" diameter for mollies (anchors). Tap mollies (anchors) into wall with hammer.
6. Secure Wall Mounting Plate to wall with six #6 x 1" long
sheet metal Phillips flat head Type A screws (part SC461).
7. To hide the screw heads installed in the previous step, a Finishing Cover Plate (HW1854) is provided. Firmly press the
Finishing Cover Plate into the Wall Mounting Plate until the
top and bottom snaps fully engage.
To enroll the IBR-ITAB into the security system using an
IBR-WIFI-MOD see WI1942; if using an ISEE-WAP see
WI2049.
CHARGING STATION INSTALLATION
3-GANG BOX
If installing the Wall Mounting Plate directly to a hollow dry wall
or similar surface, see instructions at left. To secure the Wall
Mounting Plate to a 3-gang box, proceed as follows:
1. Select the mounting location preferably at eye level for easy
viewing by the user. Reference the diagram below; with the
3-gang box installed, notice how the Wall Mounting Plate
two power wires are intended to run through the largest hole
in the Gang Box Insert into the 3-Gang Box. These two
power wires are connected to the two power wires from the
power supply that are routed into the 3-Gang Box. The
power supply is plugged into any standard 120VAC outlet
located in a basement or other distant location.
2. With the 3-Gang Box installed, snake the two power supply
wires from the transformer power source location into the 3Gang Box.
IMPORTANT: The positive power supply wire is marked
with red heat shrink tubing; be sure not to dislodge this red
marking when routing wires, as polarity MUST be maintained.
3. Run the Wall Mounting Plate two power wires through the
largest hole in the Gang Box Insert and into the 3-Gang Box.
Using wire nuts or connectors appropriate for the installation,
(SC523)
Screws (6)
(SC652) #6 x 1" long
Hi-Low Phillips flat
head screws (6)
3-Gang Box
(Installer provided)
(9HW1836ASSY)
Wall Mounting
(HW1854)
Finishin g
Cover Plate
3-Gang Box Installations
Plate
(HW1848)
Gang Box
Insert
connect the red wire from the Wall Mounting Plate to the
positive power supply wire marked with the red heat shrink
tubing. Connect the black wire from the Wall Mounting
Plate to the other black power supply wire. If the red heat
shrink tubing was dislodged and you are uncertain as to
the polarity, use a voltmeter to determine the polarity.
4. Using the 6 screws (SC523), secure the Gang Box Insert
to the 3-Gang Box as shown in the illustration above. Hide
ers (LA3001) provided.
5. Secure the Wall Mounting Plate to the Gang Box Insert
with the six #6 x 1" long Hi-Low Phillips flat head screws
(part SC652) as shown in the illustration above. Hide
these screw heads with the Finishing Cover Plate
(HW1854). Firmly press the Finishing Cover Plate into the
Wall Mounting Plate until the top and bottom snaps fully
engage.
the screw heads with the 3/8" diameter circular white stick-
WIRING OVERVIEW with IBR-ZREMOTE and ISEE-WAP
CONTROL
PANEL
STANDARD
KEYPAD
IBR-ZREMOTE
Remote Services
NETWORK
Internet
TO PANEL SERIAL PORT (only
needed for IBR-ZREMOTE CS
communication or panel
RED
BLACK
GREEN
YELLOW
KEYPAD BUS
downloading)
RED
BLACK
(((
(
(
(
IBR-ITAB-HW
THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC.
This equipment generates and uses radio-frequency energy and, if not installed and used
properly, that is, in strict accordance with the manufacturer's instructions, may cause
interference to radio and television reception. It has been type tested and found to comply with
the limits for a Class-B computing device in accordance with the specifications in Subpart J of
Part 15 of FCC Rules, which are designed to provide reasonable protection against such
interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause interference to radio or television reception, which can be determined by
Z-WAVE DEVICES
CAMERAS
(
(
(
NETWORK
GREEN
YELLOW
BROADBAND
MODEM
(((
(
(
(
(
(
(
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures: reorient the receiving antenna; relocate the computer
with respect to the receiver; move the computer away from the receiver; plug the computer into
a different outlet so that computer and receiv er are on different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician
for additional suggestions. The user may find the following booklet prepared by the Federal
Communications Commission helpful: “How to Identify and Resolve Radio-TV Interference
Problems”. This booklet is available from the U.S. Government Printing Office, Washington, DC
20402; Stock No. 004-000-00345-4.
IBR-ITAB
ISEE-WAP
(((
CUSTOMER ROUTER
(Wireless or Wired-only)
3