Napco EN50131-1 DATASHEET

GEM-P1664 Series:
8 to 64 Zone Hybrid Hardwire/Wireless Controls
Suitable for EN50131-1 Installations
The GEM-P1664 Series hardwire/
wireless control panel with
partitioning ideal to standardize
on for both residential &
commercial applications!
8 to 64 hardwire/wireless zones (including two 2-wire fire
zones)
Programmable partitioning for up to four areas
Up to 64 users
Supports full range of reliable NAPCO Wireless crystal-
control transmitters– proven to outperform leading competitive brands in independent tests!
Choice of custom alphanumeric, digital and icon keypads
Temperature display on keypad (with optional
temperature sensor), shown at left.
NAPCO manufacturing ensures product quality and is ISO9001: 2000 certified
Two configurations for every application requirement:
GEM-P1664EX model suitable for use in EN50131-1 Installations (wall mount transformer not included).
GEM-P1664EX-230 model suitable for use in EN50131-1 CE installations. Unit is CE marked and
includes internally mounted 230V transformer.
GEM-P1664 zone hybrid control
The GEM-P1664 Hybrid 8 to 64-Zone Control/ Communicator features 8 zones expandable to 64 zones with multiplexing and supports proven, reliable, NAPCO crystal-control transmitters and uses advanced helically-filtered receivers, too. Supporting up to 64 user codes and 8 16 relays, the GEM-P1664 comes in two configurations suitable for EN50131-1 and/or CE installations. This Gem control features easy “Self-Programming Plus” keypad programming (for all zones), which includes new alpha keypad question-prompts, even for setting test timer, fire zones and exit/entry and follower zones. Additionally, the panel can be remote up/downloaded using easy-to-use NAPCO Quickloader Software (V5.0 or greater) with true Windows-style functionality, including cut/paste, drop/drag, etc.
FEATURES
8 Hardwire/Wireless Zones on board
Up to 64 zones with multiplex expansion
including 2 two 2-wire fire zones
With multiplexing, can accommodate up to
64 EOL zones (from custom alpha keypads or multiplex modules)
EZ Programming2 More comprehensive,
menu-driven programming for all zones plus test timer.
Up to 64 user codes
Up to 4 areas
3 on-board outputs, up to16 external relay
outputs (RM3008s).
Up to 2 NAPCO helically-filtered, crystal-
control RF receivers
Interior bypass group with programmable
automatic interior bypass
600 event log
Auto Arm
Uses up to 7 of any of the Classic/RP- or K-
Series Stay & Away keypads
Programmable telephone line cut supervision
with delay
3 Keypad panics (F, P, A)
Supports all major communicator formats,
including: 4/2, SIA, 4+2 and Point ID, plus pager
Backup/double/split reporting; three 20-digit
telephone numbers
Dynamic battery test
Reports alarms, restores and troubles by zone.
2 programmable entry delay times
Chime by zone
8 EOL burglary zones programmable for area,
E/E delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, cross zoning , etc.
Supports series zone doubling and Loop
supervision using double EOL resistors (feature requires use of GEM-EZM4/8 Multiplex Modules)
Multiplex Expandability with GEM EZM4/8 or
GEM EZM8 zone expansion modules
Quickloader up/downloading, including
unique unattended method
Choice of RF receivers
Partitioning by area
Event log with open/close suppression
Event log viewable at keypad (total log,
burglar alarm log, fire alarm log, system trouble log, o/c log)
Cellphone-style keypad programming of zone
descriptions ( text)
Programmable 50Hz Clock Setting
Programmable Daylight Savings Time
Programmable Security Bypass (code required
for bypass)
Un-Bypassing while disarmed (code required)
Temperature Display at Keypad (-30 to 600C
Celsius or -22 to 1400F Fahrenheit) with optional GEM-TEMP64 Indoor/Outdoor Temperature Sensor (Note: Keypad Temperature Display replaces Date on Display)
Programmable High/Low Temperature Alarm
Reporting (requires feature enabled; zone 6)
24 Hour day zone trouble
Programmable security blocking of keypad
display messages –Informational displays made visible contingent on user’s assigned area(s) within system
Programmable Swinger Shutdown (2 or 3
activations – selectable)
Zone Anding/Cross Zoning (Grouping of zones
in which sequential zone activation is required to generate an alarm)
SPECIFICATIONS
Environmental Classification: Class I (+5C to +40C),
Class II (-10C to +40C) and Class III (-25C to +50C)
Input power: 16.5VAC via Class 2 plug-in 20VA, 40VA
or 50VA transformer
Loop voltage: 10-13VDCdc
Loop current: 32.5mA with 2.2k ohm EOLR; 5mA for
2-wire fire
Loop resistance: 300 ohm max.; 50 ohm max for
2-wire fire
Aux & remote power: 12VDC regulated (11.7 to
12.5VDC)
Maximum Combined standby current: 650mA
Maximum Alarm current: 2A
Burg. voltage output: 1
Programmable negative outputs: 2
Loop response 750ms, programmable 50ms to
2,000ms
POWER (With Type A Power Supply):
Grades 1 and 2 Installations with 4AH battery:
Maximum combined standby current: 210mA Maximum combined standby current and alarm current: 650mA
Grades 1 and 2 installations with 7AHbattery:
Maximum combined standby current is: 460mA Maximum combined standby current and alarm current: 500mA
Grade 3 installations (requires 7AH battery):
Maximum combined standby current is : 110mA Maximum combined standby current and alarm current: 500mA
ORDERING INFORMATION
GEM-P1664EX Control Panel suitable for use in EN50131-1 Installations (transformer not supplied). GEM-P1664EX-230 Control panel, as above, prewired with transformer (included) suitable for use in EN50131-1 CE installations., CE marked. PCD2000 NAPCO QUICKLOADER® Up/ Downloading Software For panel programming, requires version 5.0 or greater. (Windows­based). GEM-RP1CAe2 Deluxe Custom Alphanumeric Dual-Line Display Keypad with built in 4-Zone Expansion Module. Classic NAPCO user functionality. (New Black and White Decorator Styling). (Firmware Version 9A+) GEM-K1CA, as above, with STAY and AWAY user functionality. (Firmware Version 9A+)
GEM-TEMP64 Optional temperature sensor, for use with either of the two keypads above, programmable for celsius or fahrenheit. Indoor or outdoor temperature display at keypad. GEM-RP2ASe2 Alpha/Icon Keypad (Version 7 firmware+ support required). GEM-K2AS, as above, with STAY and AWAY user functionality. (Version 7 firmware+ support required). GEM-RP3DGTL Digital Keypad (Version 3 firmware+ support required). GEM-K3DGTL, as above, with STAY and AWAY user functionality. (Version 3 firmware+ support required). GEM-EZM4/8 Mulitplex Module for 4 to 8 zones expansion (supports series zone doubling and loop supervision using double EOL resistors).
GEM-EZM8 8-Zone Mulitplex Module
Choice of NAPCO Wireless Receivers & Full Range of NAPCO GEM or Libra Wireless Transmitters (consult manual for selection for your region’s frequency):
GEM-K4RF Fixed English Language Display
Keypad with 32Pt. Built-in Wireless Receiver (Version 2 firmware+). GEM-K4RF-SPAN Spanish Language version of above. Note: Other language versions, also available:
Call NAPCO International Sales for info.
LIBRA RECV255-433 255 point receiver LIBRA RECV8-433 8 point receiver LIBRA-REC16433 Wireless 16 Point Receiver LIBRAREC96433 Wireless 96 Point Receiver LIBRA-TRANS433 Wireless Door Contact LIBRA-PIR433 Wireless PIR LIBRA-KEYF433 Wireless KeyFob LIBRA-SMK433 Wireless Smoke Detector LIBRA-GB433 Wireless Glass Break Sensor GEM-RECV255 Wireless Receiver, 96 Zones GEM-RECV96 Wireless Receiver, 96 Zones GEM-RECV16 Wireless Receiver, 16 Zones GEM-RECV8 Wireless Receiver, 8 Zones GEM-TRANS2 Window/Door Transmitter, 2-Pt GEM-RTRANS Recessed Window/Door
Transmitter
GEM-KEYF Key Fob Transmitter GEM-SMK Wireless Smoke Detector GEM-PIR Wireless PIR GEM-PIRPET Wireless Pet Immune Transmitter GEM-DT Wireless Dual-Technology Sensor GEM-GB Wireless Glass-Break Detector WI1388 Instruction/Programming Manual WI1386 Instruction/Programming Manual with
RP1/K1 Keypads WI1418 GEM-EZM4/8 Zone Expansion with GEM-P1664 Control
333 Bayview Ave., Amityville, NY, USA 11701
+1.631.842.9400 +1 (631) 842-2382 fax
www.napcosecurity.com
NASDAQ: NSSC
email: 4-intl-sales@napcosecurity.com
A497 © NAPCO, 6/05
Preliminary specifications subject to change.