Napco CICP1100 DATASHEET

MICROTERM
CICP1100 Single Door Intelligent Controller
Up to 63 CIC Intelligent Controllers (Microterm, Miniterm, Smarterm or Superterm) can be intermixed on the same communications network. (A maximum of 31 Microterms are permitted on each network.) Multiple communication networks (ports) can be connected to the CardAccess® server for maximum system expansion. Controller communication choices include: hardwire (repeat or multi-drop mode), LAN/WAN, dial-up or fiber optics for maximum flexibility. The Microterm supports RS232 and RS422 communication formats for optimal system configuration.
This Intelligent Controller is UL Listed for UL294 (Access Control System Unit), UL1076 (Proprietary Burglar Alarm Unit) and UL1950 (Information Technology Equipment).**
Microterm Capacities
Cards 1400 standard
Readers (5-wire) 1 or 2 (Wiegand output)
The Microterm (CICP1100) has 2 inputs, 1 tamper alarm and 3 outputs, and is housed in a steel enclosure.
Microterm is a single-door intelligent controller designed to be installed at or near the protected door. The Microterm is capable of controlling all access control functions for one door, including two-reader support. The two-reader configuration is generally used for in-reader and out-reader applications. It is possible to use the Microterm’s 2-reader configuration on two separate doors with certain limitations. This distributed processor-based panel will operate as a standalone unit in the event server communications is interrupted. The Microterm is programmed via CIC CardAccess® software program. Once programmed, the controller does not require continuous server communications, as it automatically stores system transactions in its internal memory. The Microterm (CICP1100) has 2 inputs, 1 tamper alarm and 3 outputs, and is housed in a steel enclosure.
The Microterm accepts industry standard Wiegand output devices and supports virtually all card/reader technologies. Proximity, Biometric, Magnetic Stripe, Barcode, Wiegand, Barium Ferrite, Keypad and Smart Readers are easily connected and controlled. The Microterm can store multiple card (bit) formats in its internal memory, making it a cost-effective retrofit panel. Supporting multiple bit formats allows existing card populations and readers to remain in place. An optional standby battery is available, providing 4-6 hours standby power. The Microterm includes a lithium battery for up to one year of data protection.
Keypads (5-wire) 1 or 2 (Wiegand output)
Keypads (7-wire) 1 X-Y Matrix type
Readers w/Keypad
Standard Inputs
Expanded Inputs
Standard Outputs
Expanded Outputs
Transaction Buffer
Time Schedules 128
Access Groups 1000
Holidays 50
Reader Power 100mA@5VDC
Battery Backup
Enclosure
UL Listings UL294, UL1076, UL1950**
** UL1950 replaced with EN60950 in Q2/2003
1 5-wire Reader with 1 X-Y Matrix Keypads
2 (Supervised)
N/A
3 Form C rated at 3A@24VDC/VAC
N/A
1000 Standard (exp. to 30,000)
4-6 hours (optional)
Size 7.5”H x 7.5”W x 2”D, 2lbs.
Continental Instruments, A Napco Security Group Company 355 Bayview Ave., Amityville, NY 11701
(631) 842-9400 FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H
t
C
u
Door Lock
G
G
C
3000
abase and
C
s
S
r
CICE1940
1
r
2
Required if server is not located
0
k
000
p
.
p
p
2
000'
2
000'
2
000'
2
000'
2
32
50'
i
m
Sm
Microterm Components
QTY. Part No. Description
1
1
1
1 Optional
CICP1100
Standard
Standard
CICP1100BAT-2
Typical Door Configuration
See Continental Instruments Configuration Guide for additional detailed system wiring information.
A or B
RS422 to Panels
Stand-alone single- or two-door controller with standard 1,400 card capacity, 2 alarm inputs, tamper alarm, 3 relay outputs and printer output. Unit ships complete in a steel enclosure.
12VDC Wallmount Power Supply included.
15-conductor wiring Harness included.
CICP1100BAT-2 Battery Standby - Input 120VAC, Output 12VDC to temporary power the Microterm only in the event of a power failure.
G
Door Contact
ardAccess
Dat ommunication
Door Lock
Power Supply
Continental
Instruments llc
G
Request
to Exit
Electric
H
Door Strike
NOTE: Request to Exit motion detectors will require
an additional 12VDC power cable. Exit devices are typically mounted on the egress side of door.
Polling Line Converte
RS232 to RS42
within 5
RS2
Max.
erve
ard Reader
G
Request
to Exit B
PL-
42
. 4
Request to Exi
Motion Detector
Door Contact
G
ertermSu
CICP1100 Single Door Intelligent Controller
Continental Instrument’s Controllers can connect to the CardAccess Server via hardwire (shown below), LAN/WAN dial-up modem or fiber optics. See the CIC Configuration Guide for additional detailed system information.
RS422 Repeat Mode Communications Networ
4
' max. distance between controllers.
to 63 controllers on a Repeat Mode Network
U
RS42
Max. 4
RS42
Max. 4
ertermSu
RS42
Max. 4
arter
RS42
nitermM
Continental Instruments, A Napco Security Group Company 355 Bayview Ave., Amityville, NY 11701
(631) 842-9400 FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H
CardAccess® and CI SQL 3000™ are trademarks of Continental/NAPCO. © Continental Instruments/NAPCO, 2003.