NAIS JQ1P-B-9V, JQ1P-B-6V, JQ1P-B-24V, JQ1P-B-18V, JQ1P-B-12V Datasheet

...
71
JQ RELAYS
VDE
HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY
mm inch
20
.787
10
.394
15.6
.614
FEATURES
• High electrical noise immunity
• High switching capacity in a compact package
• High sensitivity: 200 mW (1a), 400 mW (1c)
• High surge voltage: 8,000 V between contacts and coil
• UL, CSA, VDE, TÜV, SEMKO approved
• Class B coil insulation type available
SPECIFICATIONS
Contact
Expected electrical life (min. operations)
Coil (at 20°C 68°F)
Characteristics
Remarks
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as "Initial breakdown voltage" section *2Detection current: 10 mA *3Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *
4
Excluding contact bounce time *5Measured conditions
*
6
Half-wave pulse of sine wave: 11ms; detection time: 10µs *7Half-wave pulse of sine wave: 6ms *8Detection time: 10µs *
9
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24). *
10
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F
with 20°C 68°F as a reference) and use a coil impressed voltage that is within
the maximum allowable voltage range.
Standard type High capacity type
Arrangement 1 Form A, 1 Form C
Initial contact resistance, max. (By voltage drop 6 V DC 1 A)
100 m
Contact material Silver alloy
Rating
(resistive)
Nominal switching capacity
1a
5 A 125 V AC 2 A 250 V AC
5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
1c
N.O.
5 A 125 V AC 2 A 250 V AC
3 A 30 V AC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
N.C.
2 A 125 V AC 1 A 250 V AC
1 A 30 V DC
3 A 125 V AC 2 A 250 V AC
1 A 30 V DC
Max. switching power
1a 625 VA, 150 W 1,250 VA, 150 W
1c
N.O. 625 VA, 90 W 1,250 V AC, 150 W N.C. 250 VA, 30 W 500 V AC, 30 W
Max. switching voltage
250 V AC, 110 V DC (0.3A)
Max. switching current
N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A
Expected mechanical life (at 180 cpm)(min. operations)
10
7
Type Switching capacity No. of operations
Standard type
1a
5 A 125 V AC 3 A 125 V AC 2 A 250 V AC
5 A 30 V DC
5×10
4
2×10
5
2×10
5
10
5
1c
N.O.
5 A 125 V AC 2 A 250 V AC
3 A 30 V DC
5×10
4
2×10
5
10
5
N.C.
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
2×10
5
2×10
5
10
5
High capacity type
1a
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
1c
N.O.
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
N.C.
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
2×10
5
2×10
5
10
5
Nominal operating power 1a: 200 mW 1c: 400 mW
Max. operating speed 20 cpm Initial insulation resistance*
1
Min. 1,000 MΩ at 500 V DC
Initial breakdown voltage*
2
Between open contacts
1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
Between contacts and coil
4,000 Vrms for 1 min.
Surge voltage between contact and coil*
3
8,000 V
Operate time*4 (at nominal voltage) Approx. 5 ms Release time*
4
(at nominal voltage)(without diode)
Approx. 2 ms
Temperature rise*
5
Max. 45°C
Shock resistance
Functional*
6
Min. 294 m/s2 {30 G}
Destructive*
7
Min. 980 m/s2 {100 G}
Vibration resistance
Functional*
8
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
Destructive
117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm
Conditions for operation, transport and storage*
9
(Not freezing and condens­ing at low temperature)
Ambient temp.*
10
–40°C to +85°C
–40°F to +185°F
Humidity 5 to 85% R.H.
Unit weight Approx. 7 g .25 oz
Standard type
Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C 158°F
High capacity type
Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C 158°F
JQ
72
TYPES AND COIL DATA at 20°C 68°F
Part No.
Nominal
voltage, V DC
Pick-up
voltage, V DC
(min.)
Drop-out
voltage, V DC
(min.)
Nominal
operating
current, mA
Nominal
operating
power, mW
Coil resistance,
Ω (±
10%)
Max. allowable
voltage, V DC
1 Form A
Standard type
JQ1a-5V 5 3.75 0.25 40
200
125
180% of
nominal voltage
(at 20°C 68°F)
JQ1a-6V 6 4.5 0.3 33.3 180 JQ1a-9V 9 6.75 0.45 22.2 405 JQ1a-12V 12 9 0.6 16.7 720 JQ1a-18V 18 13.5 0.9 11.1 1,620 JQ1a-24V 24 18 1.2 8.3 2,880
High capacity type
JQ1aP-5V 5 4 0.25 40
200
125
130% of nominal voltage (at 85°C 185°F)
JQ1aP-6V 6 4.8 0.3 33.3 180 JQ1aP-9V 9 7.2 0.45 22.2 405 JQ1aP-12V 12 9.6 0.6 16.7 720 JQ1aP-18V 18 14.4 0.9 11.1 1,620 JQ1aP-24V 24 19.2 1.2 8.3 2,880
1 Form C
Standard type
JQ1-5V 5 3.75 0.25 80
400
62.5
150% of nominal voltage
(at 20°C 68°F)
JQ1-6V 6 4.5 0.3 66.7 90 JQ1-9V 9 6.75 0.45 44.4 202.5 JQ1-12V 12 9 0.6 33.3 360 JQ1-18V 18 13.5 0.9 22.2 810 JQ1-24V 24 18 1.2 16.7 1,440 JQ1-48V 48 36 2.4 8.3 5,760
High capacity type
JQ1P-5V 5 4 0.25 80
400
62.5
110% of nominal voltage (at 85°C 185°F)
JQ1P-6V 6 4.8 0.3 66.7 90 JQ1P-9V 9 7.2 0.45 44.4 202.5 JQ1P-12V 12 9.6 0.6 33.3 360 JQ1P-18V 18 14.4 0.9 22.2 810 JQ1P-24V 24 19.2 1.2 16.7 1,440 JQ1P-48V 48 38.4 2.4 8.3 5,760
TYPICAL APPLICATIONS
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
ORDERING INFORMATION
Contact
arrangement 1a: 1 Form A
1: 1 Form C
Nil: Standard P: High capacity
5, 6, 9, 12, 18, 24, 48* V
Contact capacity
Nil: Class E coil insulation B: Class B coil insulation
Coil insulation class Coil voltage (DC)
UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type
1a P BEx. JQ 12 V