COMPACT POWER RELAYS
mm inch
30.4
1.197
30.0
1.181
19.0
.748
FEATURES
• High inrush current capability
1 Form A: 163 A inrush (TV-8)
2 Form A: 111 A inrush (TV-5)
• High dielectric withstanding for transient protection:
JC can withstand 10,000 V surge in µ s between coil and contact.
• Electrical life:
1 Form A: 10
5
ope. at 15 A 250 V AC resistive load
2 Form A: 10
5
ope.
at 10 A 250 V AC resistive load
• TÜV also approved
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form A 2 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
30 m Ω
(Cd free type: 100 m Ω )
Contact material Silver alloy
Contact force, min. 30 g
Rating
(resistive
load)
Maximum switching power 3,750 VA 2,500 VA
Maximum switching volt-
age
250 V AC 250 V AC
Max. switching current 15 A 10 A
Expected
life (min.
operation)
Mechanical 5 × 10
6
Electrical
(resistive)
10 A 250 V AC 10
5
—
5A 250 V AC — 10
5
Minimum operating power 576 mW 640 mW
Nominal operating power 900 mW 1,000 mW
Maximum operating speed 20 cpm.
Initial insulation resistance*
1
Min. 100 M Ω at 500 V DC
Initial
breakdown
voltage*
2
Between open contacts
2,000 V rms for 1 min.
(N.C. contact of 1a1b: 1,000 Vr ms)
Between contacts sets
2,000 Vrms for 1 min.
Between contacts and coil
4,000 Vrms for 1 min.
Operate time*
3
(at nominal voltage)
Approx. 15 ms
Release time(without diode)*
3
(at nominal voltage)
Approx. 2 ms
Temperature rise
(at nominal voltage)
Max. 55 ° C
Shock
resistance
Functional*
4
196 m/s
2
{20 G}
Destructive*
5
980 m/s
2
{100 G}
Vibration
resistance
Functional*
6
98 m/s
2
{10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
[1a1b type at double amplitude:
1.0 mm, 58.8 m/s
2
{6 G}]
Destructive
117.6 m/s
2
{12 G}, 10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation,
transport and storage*
7
(Not freezing and condensing at low temperature)
Ambient
temp.
–50 ° C to +60 ° C –58 ° F to +140 ° F
Humidity 5 to 85%R.H.
Unit weight Approx. 31 g 1.09 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement of same location as "Intial breakdown voltage" section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10 µ s
*
7
Refer to 5. Conditions for operation, transpor t and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
TYPICAL APPLICATIONS
Automatic garage door openers
Microwave ovens
Dryers
Vending machines
Copiers
Air conditioners
Stereo equipment
TV sets
ORDERING INFORMATION
1a F TM DC12VEx. JC
Contact
arrangement
1a: 1 Form A
2a: 2 Form A
Nil: PC board terminal
S: Plug-in terminal
TM: Top mounting
DC 5, 6, 12, 24, 48 V
(Notes) 1. TV rated types available 1 Form A: TV 8; 2 Form A: TV-5.
Notes ))2. For UL/CSA recognized types, add suffix UL/CSA.
Notes ))3. Standard packing Carton: 50 pcs.; Case: 200 pcs.
Notes ))4. For Cd free contact material type, add suffix “-F”.
Mounting classification Coil voltage