110
JA-RELAYS
1 HORSE-POWER
COMPACT POWER RELAYS
TMP type TM type
mm inch
34.7
1.366
28.5
1.122
30.1
1.185
34.7
1.366
28.5
1.122
30.1
1.185
FEATURES
• High switching capacity — 55 A inrush, 15 A steady state
inductive load (1 Form A)
• Particularly suitable for air conditioners, dish washers, mi-
crowave ovens, ranges, central cleaning systems, copiers,
facsimiles, etc.
• Two types available
"TM" type for direct chassis mounting
"TMP" type for PC board mounting
• TV-rated types available
• TÜV also approved
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement
1 Form, A, 1 Form B, 1 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
30 m Ω
Contact material Silver alloy
Rating
(resistive
load)
Maximum switching power 3,750 VA
Maximum switching voltage 250 V AC
Max. switching current 15A
Expected
life (min.
operations)
Mechanical (at 180 cpm.) 5 × 10
6
Electrical
(at 20 cpm.)
1 Form A (Inrush 55 A,
Steady 15 A 250 VAC
cos
ϕ
= 0.7)
10
5
1 Form B, 1 Form C
(15 A 250 VAC,
cos ϕ = 1)
5 × 10
5
Nominal operating
power
DC type 1.2 W
AC type
1.4 VA (50 Hz)/1.3 VA (60 Hz)
Minimum operating
power
DC type 0.77 W
AC type
0.90 VA (50 Hz)/0.84 V A (60 Hz)
Maximum operating speed 20 cpm.
Initial insulation resistance*
1
Min. 100 M Ω at 500 V DC
Initial breakdown voltage*
2
Between open contacts
1,500 Vrms
Between contacts and coil
2,000 Vrms
Initial surge voltage between contacts
and coil*
3
Min. 5,000 V
Operate time*
4
(at 20 ° C) (at nominal voltage)
Approx. 10 ms*
5
Release time (without diode)*
4
(at 20 ° C) (at nominal voltage)
Approx. 2 ms*
5
Temperature rise (at 50 ° C)
(resistive)
Max. 70 ° C
Shock resistance
Functional*
6
98 m/s
2
{10 G}
Destructive*
7
980 m/s
2
{100 G}
Vibration
resistance
Functional*
8
88.2 m/s
2
{9 G}, 10 to 55 Hz
at double amplitude of 1.5 mm
Destructive
88.2 m/s
2
{9 G}, 10 to 55 Hz
at double amplitude of 1.5 mm
Conditions for operation,
transport and storage*
9
(Not freezing and condensing at low temperature)
Ambient
temp.
–10 ° C to +50 ° C
+14 ° F to +122 ° F
Humidity 5 to 85%R.H.
Unit weight Approx. 44 g 1.55 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
For the AC coil types, the operate/release time will diff er depending on the phase.
*
6
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
7
Half-wave pulse of sine wave: 6ms
*
8
Detection time: 10 µ s
*
9
Refer to 5. Conditions for operation, transpor t and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
TYPICAL APPLICATIONS
Air conditioners, microwave ovens, load
management equipment, copiers, process
control equipment
ORDERING INFORMATION
1a TM DC12V PEx. JA
Contact
arrangement
1c: 1 Form C
1a: 1 Form A
1b: 1 Form B
(Notes) 1. For UL/CSA recognized types, add suffix UL/CSA.
(Notes) 2. Standard packing Carton: 20 pcs.; Case: 200 pcs.
TM: Solder Terminal
TMP: Solder Teminal
and PCB Teminal
Nil: Standard type
P: Up-graded contact
rating type
(See next page)
DC 12, 24 V
AC 12, 24, 115 V
Mounting classification Coil voltage Classification