NAIS HP2-AC48V, HP2-AC6V, HP2-DC110V, HP2-DC12V, HP2-DC48V Datasheet

...
411
HP-RELAYS
10 AMP POWER RELAY
2c, 3c
mm inch
25
.984
36
1.417
44.5
1.752
FEATURES
• Interchangeable with existing models
• Long life and high reliability
• High contact capacity up to 10 A 250 V AC
• Available with plug-in/solder and quick-connect terminals
SPECIFICATIONS (at 20 ° C 68 ° F)
Contacts
Remarks
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as "initial breakdown voltage" section
*
2
Detection current; 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10 µ s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 60 Hz, 20 ° C 68 ° F)
Arrangement 2 Form C 3 Form C 4 Form C Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
15 m Ω
Contact material Silver
Silver
alloy
Rating
Nominal switching capacity
10 A 250 V AC (resistive)
2 Form C 3 Form C 4 Form C Maximum operating speed 20 cpm Initial insulation resistance*
1
more than 100 M Ω at 500 V DC
Breakdown voltage*
2
Between open contacts
1,000
Vrms
2,000 Vrms
1,000 Vrms
Between contact sets
1,500
Vrms
2,000 Vrms
1,500 Vrms
Between contact and coil
1,500
Vrms
2,000 Vrms
1,500 Vrms
Operate time*
3
(at nominal voltage)
Approx.
15 ms
Approx. 25 ms
Release time (without diode)*
3
(at nominal voltage)
Approx.
15 ms
Approx. 25 ms
Temperature rise Max. 65 ° C Shock resistance
Functional*
4
98 m/s
2
{10 G}
Destructive*
5
980 m/s
2
{100 G}
Vibration resistance
Functional*
6
58.8 m/s
2
{6 G}, 10 to 55 Hz
at 1 mm double amplitude
Destructive
117.6 m/s
2
{12 G}, 10 to 55 Hz
at 2 mm double amplitude
Conditions for opera­tion, transport and storage*
7
(Not freezing and condensing at low temperature)
Ambient temp.
–50 ° C to +40 ° C
–58 ° F to +104 ° F
Humidity 5 to 85% R.H.
Unit weight
Approx.
60g
2.12 oz
Approx.
100g
3.53 oz
Approx.
125g
4.41 oz
LIFE DATA
Contact rating and expected life For AC load type
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
Voltage 125 V AC 250 V AC
Expected life
(min. operations)
Electrical
life
Load Resistive (cos ϕ
]
1) Inductive (cos ϕ
]
0.4) Resistive (cos ϕ
]
1) Inductive (cos ϕ
]
0.4)
Current
10 A 7.5 A 2 × 10
5
10 A 7.5 A 7.5 A 5 A 5 × 10
5
5 A3 A3 A2 A1
×
10
6
1A 0.7 A 0.6 A 0.4 A 2 × 10
6
Mechanical life 1 × 10
7
HP
412
Contact rating and expected life For DC load type
Voltage 24 V DC 125 V DC
Expected life
(min. operations)
Electrical
life
Load Resistive (cos ϕ
]
1) Inductive (cos ϕ
]
0.4) Resistive (cos ϕ
]
1) Inductive (cos ϕ
]
0.4)
Current
—7 A— —2
×
10
5
7.5 A 5 A 0.5 A 0.4 A 5 × 10
5
5 A 3 A 0.3 A 0.2 A 1 × 10
6
1A 0.6 A 0.1 A 0.06 A 2 × 10
6
Mechanical life 1 × 10
7
Life curve
Notes:
1. F or DC inductive loads, use an arc suppress­ing circuit.
2. When used under a DC load operating at high repetition rate with considerable arcing, corrosion of the contacts and/or the contact blades is likely to occur. When using the relay under conditions of high temperature, humidity or high repetition rate, it is suggested that the relay cover be removed to facilitate extended operation.
10
0
100
200
300
400
500
600
700
800
900
1,000
Load current, A
Operations, ×10
4
125 V AC cosϕ = 1
5
2
5
0
V
A
C
c
o
s
ϕ
=
1
Mechanical life more than 10,000,000 operations
TYPICAL APPLICATIONS
HP relays enjoy wide use in v arious appli­cations, particularly in automation con­trols and remote controls. Applications include: Industrial machinery
Machine tool Food processing packing machines Office equipment Coin operate devices Home appliances
Transportation Communication and measuring devices Amusement devices
ORDERING INFORMATION
Ex. HP 3
Contact arrangement
2: 2 Form C 3: 3 Form C 4: 4 Form C
(Notes) 1. For UL/CSA or VDE recognized types, add suffix UL/CSA or VDE (HP2-TM type VDE application under way)
2. Standard packing Carton: 50 pcs. Case: 200 pcs.
3. UL/CSA approved type is standard.
Nil: Standard plug-in terminal M: Direct mounting (3 Form C only) TM: Top mounting (2 Form C only) L: Lamp wired, standard plug-in terminal
AC 6, 12, 24, 48, 115, 220, 240 V DC 6, 12, 24, 48, 110 V
Terminal Coil voltage
M AC240V
TYPES AND COIL DATA
1. Standard plug-in terminal type (without lamp wired)
DC TYPES at 20 ° C 68 ° F
Type Part No.
Nominal coil
voltage, V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable
voltage, V DC
Coil
resistance,
Ω ( ±
10%)
Nominal coil
current, mA
Nominal operating power, W
2 Form C
HP2-DC6V 6 4.8 0.9 6.6 25 240 1.5 HP2-DC12V 12 9.6 1.8 13.2 110 109 1.3 HP2-DC24V 24 19.2 3.6 26.4 440 54.5 1.3 HP2-DC48V 48 38.4 7.2 52.8 1,800 26.7 1.3 HP2-DC110V 110 88 16.5 121 7,300 15.0 1.7
3 Form C
HP3-DC6V 6 4.8 0.9 6.6 24 250 1.5 HP3-DC12V 12 9.6 1.8 13.2 100 120 1.4 HP3-DC24V 24 19.2 3.6 26.4 400 60 1.4 HP3-DC48V 48 38.4 7.2 52.8 1,560 31 1.5 HP3-DC110V 110 88 16.5 121 7,450 14.9 1.6
4 Form C
HP4-DC6V 6 4.8 0.9 6.6 22 273 1.6 HP4-DC12V 12 9.6 1.8 13.2 95 127 1.5 HP4-DC24V 24 19.2 3.6 26.4 380 63 1.5 HP4-DC48V 48 38.4 7.2 52.8 1,500 32 1.5 HP4-DC110V 110 88 16.5 121 7,000 15.7 1.7
HP
413
AC TYPE (50/60 Hz) at 60 Hz, 20 ° C 68 ° F
Type Part No.
Nominal coil
voltage, V AC
Pick-up
voltage,
V AC (max.)
Drop-out
voltage,
V AC (min.)
Max.
allowable
voltage, V AC
Inductance, HNominal coil
current, mA
Nominal
operating
power, VA
2 Form C
HP2-AC6V 6 4.8 1.8 6.6 0.049 310 1.9 HP2-AC12V 12 9.6 3.6 13.2 0.190 160 1.9 HP2-AC24V 24 19.2 7.2 26.4 0.776 78 1.9 HP2-AC48V 48 38.4 14.4 52.8 3.106 39 1.9 HP2-AC115V 115 92 34.5 126.5 15.83 18 2.1 HP2-AC220V 220 176 66 242 57.90 9.5 2.1 HP2-AC240V 240 192 72 264 66.26 9.0 2.2
3 Form C
HP3-AC6V 6 4.8 1.8 6.6 0.030 520 3.1 HP3-AC12V 12 9.6 3.6 13.2 0.119 260 3.1 HP3-AC24V 24 19.2 7.2 26.4 0.475 130 3.1 HP3-AC48V 48 38.4 14.4 52.8 1.899 65 3.1 HP3-AC115V 115 92 34.5 126.5 10.36 28.5 3.3 HP3-AC220V 220 176 66 242 39.32 14.2 3.1 HP3-AC240V 240 192 72 264 44.05 13.9 3.3
4 Form C
HP4-AC6V 6 4.8 1.8 6.6 0.019 800 4.8 HP4-AC12V 12 9.6 3.6 13.2 0.077 400 4.8 HP4-AC24V 24 19.2 7.2 26.4 0.309 200 4.8 HP4-AC48V 48 38.4 14.4 52.8 1.292 95 4.6 HP4-AC115V 115 92 34.5 126.5 6.953 42 4.8 HP4-AC220V 220 176 66 242 26.57 21 4.6 HP4-AC240V 240 192 72 264 29.75 20.5 4.9
NOTES
1. The range of coil current for AC relays is ± 15% (60 Hz). For DC relays it is
±
10% at 20 ° C, 68 ° F.
2. The HP relay will operate in a range from 80% to 110% of the nominal coil voltage. It is, however, recommended that the relay be used in the range of 85% to 110% of the nominal coil volt­age, with the temporary voltage varia­tion taken into consideration.
3. When the operating voltage of AC re-
lays drops below 80% of the nominal coil voltage, the relay will generate a considerable amount of heat which is not recommended for maximum effi­ciency.
4. The coil resistance of DC types is the measured value of the coil at a temper­ature of 20 ° C 68 ° F. If the coil tempera- ture changes by ± 1 ° C, the measured value of the coil resistance should be increased or decreased by 0.4%.
5. For applications from 220 V to 240 V DC, connect a resistor in series with the relay coil. See chart for resistor val­ues.
Voltage 2 Form C 3 Form C 4 Form C
220 V DC
7.3 k Ω (5 W)
7.45 k Ω (5 W)
7 k Ω
(5 W)
240 V DC
8.7 k Ω (5 W)
8.8 k Ω (5 W)
8.3 k Ω (5 W)
2. Standard plug-in terminal type (with lamp wired)
DC TYPES at 20 ° C 68 ° F
Type Part No.
Nominal coil
voltage,
V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable
voltage,
V DC
Coil
resistance,
Ω ( ±
10%)
Nominal coil
current,
mA
Nominal
operating
power,
W
2 Form C
LED
HP2-L-DC6V 6 4.8 0.9 6.6 25 240 1.5 HP2-L-DC12V 12 9.6 1.8 13.2 110 109 1.3 HP2-L-DC24V 24 19.2 3.6 26.4 440 54.5 1.3 HP2-L-DC48V 48 38.4 7.2 52.8 1,800 26.7 1.3
Neon lamp HP2-L-DC110V 110 88 16.5 121 7,300 15.0 1.7
3 Form C
LED
HP3-L-DC6V 6 4.8 0.9 6.6 24 250 1.5 HP3-L-DC12V 12 9.6 1.8 13.2 100 120 1.4 HP3-L-DC24V 24 19.2 3.6 26.4 400 60 1.4 HP3-L-DC48V 48 38.4 7.2 52.8 1,560 31 1.5
Neon lamp HP3-L-DC110V 110 88 16.5 121 7,450 14.9 1.6
4 Form C
LED
HP4-L-DC6V 6 4.8 0.9 6.6 22 273 1.6 HP4-L-DC12V 12 9.6 1.8 13.2 95 127 1.5 HP4-L-DC24V 24 19.2 3.6 26.4 380 63 1.5 HP4-L-DC48V 48 38.4 7.2 52.8 1,500 32 1.5
Neon lamp HP4-L-DC110V 110 88 16.5 121 7,000 15.7 1.7
HP
414
AC TYPE (50/60 Hz) at 60 Hz, 20 ° C 68 ° F
3. Top Mounting (TM) and direct mounting (M) type
DC TYPES at 20 ° C 68 ° F
AC TYPE (50/60 Hz) at 60 Hz, 20 ° C 68 ° F
Type Part No.
Nominal coil
voltage,
V AC
Pick-up voltage,
V AC (max.)
Drop-out
voltage,
V AC (min.)
Max.
allowable
voltage,
V AC
Inductance,
H
Nominal coil
current,
mA
Nominal
operating
power,
VA
2 Form C
LED
HP2-L-AC6V 6 4.8 1.8 6.6 0.049 310 1.9 HP2-L-AC12V 12 9.6 3.6 13.2 0.190 160 1.9 HP2-L-AC24V 24 19.2 7.2 26.4 0.776 78 1.9
Neon lamp
HP2-L-AC115V 115 92 34.5 126.5 15.83 18 2.1 HP2-L-AC220V 220 176 66 242 57.90 9.5 2.1 HP2-L-AC240V 240 192 72 264 66.26 9.0 2.2
3 Form C
LED
HP3-L-AC6V 6 4.8 1.8 6.6 0.030 520 3.1 HP3-L-AC12V 12 9.6 3.6 13.2 0.119 260 3.1 HP3-L-AC24V 24 19.2 7.2 26.4 0.475 130 3.1
Neon lamp
HP3-L-AC115V 115 92 34.5 126.5 10.36 28.5 3.3 HP3-L-AC220V 220 176 66 242 39.32 14.2 3.1 HP3-L-AC240V 240 192 72 264 44.05 13.9 3.3
4 Form C
LED
HP4-L-AC6V 6 4.8 1.8 6.6 0.019 800 4.8 HP4-L-AC12V 12 9.6 3.6 13.2 0.077 400 4.8 HP4-L-AC24V 24 19.2 7.2 26.4 0.309 200 4.8
Neon lamp
HP4-L-AC115V 115 92 34.5 126.5 6.953 42 4.8 HP4-L-AC220V 220 176 66 242 26.57 21 4.6 HP4-L-AC240V 240 192 72 264 29.75 20.5 4.9
Type Part No.
Nominal coil
voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable
voltage,
V DC
Coil
resistance,
Ω ( ±
10%)
Nominal coil
current,
mA
Nominal
operating
power,
W
2 Form C
Top Mounting Type (TM)
HP2-TM-DC6V 6 4.8 0.9 6.6 25 240 1.5 HP2-TM-DC12V 12 9.6 1.8 13.2 110 109 1.3 HP2-TM-DC24V 24 19.2 3.6 26.4 440 54.5 1.3 HP2-TM-DC48V 48 38.4 7.2 52.8 1,800 26.7 1.3 HP2-TM-DC110V 110 88 16.5 121 7,300 15.0 1.7
3 Form C
Direct Mounting Type (TM)
HP3-M-DC6V 6 4.8 0.9 6.6 24 250 1.5 HP3-M-DC12V 12 9.6 1.8 13.2 100 120 1.4 HP3-M-DC24V 24 19.2 3.6 26.4 400 60 1.4 HP3-M-DC48V 48 38.4 7.2 52.8 1$B!"(J560 31 1.5 HP3-M-DC110V 110 88 16.5 121 7,450 14.9 1.6
Type Part No.
Nominal coil
voltage,
V AC
Pick-up voltage,
V AC (max.)
Drop-out
voltage,
V AC (min.)
Max.
allowable
voltage,
V AC
Inductance,
H
Nominal coil
current,
mA
Nominal
operating
power,
VA
2 Form C
Top Mounting Type (TM)
HP2-TM-AC6V 6 4.8 1.8 6.6 0.049 310 1.9 HP2-TM-AC12V 12 9.6 3.6 13.2 0.190 160 1.9 HP2-TM-AC24V 24 19.2 7.2 26.4 0.776 78 1.9 HP2-TM-AC48V 48 38.4 14.4 52.8 3.106 39 1.9 HP2-TM-AC115V 115 92 34.5 126.5 15.83 18 2.1 HP2-TM-AC220V 220 176 66 242 57.90 9.5 2.1 HP2-TM-AC240V 240 192 72 264 66.26 9.0 2.2
3 Form C
Direct Mounting Type (M)
HP3-M-AC6V 6 4.8 1.8 6.6 0.030 520 3.1 HP3-M-AC12V 12 9.6 3.6 13.2 0.119 260 3.1 HP3-M-AC24V 24 19.2 7.2 26.4 0.475 130 3.1 HP3-M-AC48V 48 38.4 14.4 52.8 1.899 65 3.1 HP3-M-AC115V 115 92 34.5 126.5 10.36 28.5 3.3 HP3-M-AC220V 220 176 66 242 39.32 14.2 3.1 HP3-M-AC240V 240 192 72 264 44.05 13.9 3.3
Loading...