Nady Systems USB-2S User Manual

ONE YEAR WARRANTY
Nady Systems, Inc. warrants to the original consumer purchaser that your unit is free from any defects in material or workmanship for a period of one year from the date of purchase. If any such defect is discovered within the warranty period, Nady Systems, Inc. will repair
or malfunction upon delivery or shipping prepaid to Nady Systems.
This warranty does not apply to defects or physical damage resulting from abuse, neglect, accident, improper repair, alteration, or unreasonable use of the unit resulting in cracked or broken cases or parts, or units damaged by excessive heat, and does not apply to batteries or damage caused by leaking batteries. This warranty does
not cover nish or appearance items nor items damaged in shipment
en route to Nady Systems, Inc. for repair. You must include proof of date and place of purchase (i.e., photocopy of your bill of sale) or we cannot be responsible for repairs or replacement. See Service section for further instructions.
Any applicable implied warranties including warranties of
merchantability and tness are hereby limited to one year from
date of purchase. Consequential or incidental damages resulting from a breach of any applicable express or implied warranties are hereby excluded. This warranty is in lieu of all other agreements and warranties, general or special, express or implied and no representative or person is authorized to assume for us any other liability in connection with the sale or use of this Nady Systems’ product.
USB-2S MICROPHONE
STEREO CONDENSER MICROPHONE
WITH USB AUDIO INTERFACE
Note: Some states do not allow limitations on how long implied warranties last and do not allow exclusion of incidental or consequential damages, so the above limitations and exclusions may not
apply to you. This warranty gives you specic legal rights, and you may also have other rights
which may vary from state to state.
International Customers: For service, please contact the NADY AUDIO distributor in your
country via the dealer from whom you purchased this product.
www.nady.com
6701 Shellmound Street | Emeryville, CA USA 94608
T 510.652.2411 | F 510.652.5075
Made In China
USB-2S MICROPHONE
STEREO CONDENSER MICROPHONE WITH USB AUDIO INTERFACE
Congratulations on your purchase of the Nady USB-2S Condenser Microphone. The USB-2S allows for stereo recording to a computer such as live performances in any environment. It is a useful tool for VOIP, multimedia, news and broadcast applications using netbooks and laptops for remote stereo recording of concerts,
lectures, or even ambient outdoor sounds in stereo for and TV. With the USB-2S
you are given the opportunity to record performances and sound effects from anywhere in the world on a computer in full stereo.
FEATURES
• Perfect for high quality stereo recordings of vocals and acoustic instruments
• Two capsules in an X/Y pattern
• Connects directly to any computer with a USB 2.0 (or higher) input port for
easy plug & play operation
• Features two large pressure-gradient condenser gold-sputtered diaphragm for
warm, natural reproduction
• Full frequency response with rich warmth and crisp, transparent audio
• Minimal noise, wide dynamic range, and maximum SPL capacity
• Rugged compact construction with protective mesh grill
• Basemount mic holder ts any standard mic stand
• 10’ USB cable included
UNPACKING, INSPECTION, STORAGE AND TRANSPORT
Your USB-2S microphone was carefully packed at the factory, and the carton was designed for protection during shipping. Please retain this container in the unlikely event the microphone needs to be returned for servicing.
STANDARD ITEMS SUPPLIED
USB-2S Microphone 10’ USB cable Microphone Basemount User Guide
Warranty Card
GETTING STARTED
Windows 7 / Vista
1. Connect the USB-2S to the computer using the supplied USB cable. The LED
will light to indicate that the microphone is receiving USB power. Windows
will automatically install the drivers. The USB-2S is now recognized as a win­dows audio input device.
2. The USB-2S should be recognized and assigned as default input device. Should this not occur, it can be assigned manually by accessing Sounds and Audio Devices in Control Panel. To set your USB-5H as the default device and change computer-controlled gain, access the control panel Select “Nady USB
Microphone” as Sound recording Default device under the Audio tab. Most re-
cording software allows user to select which device to use within the program itself.
4. Adjust headphone level using volume control on the USH-2S microphone
Windows XP
1. Connect the USB-2S to the computer using the supplied USB cable. The
LED will light to indicate that the microphone is receiving USB power. Windows
will automatically install the drivers. The USB-2S is now recognized as a win­dows audio input device.
2. The USB-2S should be recognized and assigned as default input device. Should this not occur, it can be assigned manually by accessing Sounds and Audio Devices in Control Panel. To set your USB-2S as the default device and change computer-controlled gain, access the control panel Select “Nady USB
OPTIONAL ACCESSORIES
Shockmount (SSM-3)
Foam windscreen (FW-2)
Microphone Pop Filter with stand clamp (MPF-6) Mic stand with boom (MST-5B)
Microphone shockmount/pop lter (SSPF-4)
Sony Acid 8 Software
Microphone” as Sound recording Default device under the Audio tab. Most re­cording software allows user to select which device to use within the program itself.
3. Adjust headphone level using volume control on the USH-2S microphone
Mac OSX
1. Connect the USB-2S to the computer using the supplied USB cable. The LED will light to indicate that the microphone is receiving USB power.
2. Congure your DAW software to select the microphone as your input device.
This can usually be done in your Hardware Options by selecting “Nady USB Mi­crophone”. 3 The USB-2S should be recognized and assigned as default input device. Should this not occur, it can be assigned manually by accessing Sound options under System Preferences. The microphone LED will blink when it is communi­cating properly with your software.
4. Adjust headphone level using volume control on the USH-2S microphone
Depending on the application, the mic can either be handheld or mounted on any microphone stand or desktop stand with the supplied mount. Be aware of feedback. This can be caused by microphone being too close to speakers. Ex­perimenting with the position of the mic with respect to the audio source will ensure the optimum results you are seeking in any given application.
SPECIFICATIONS
Type.........................Condenser microphone w/2 pressure gradient diaphragms
Frequency Response ............................................................20 Hz – 20K Hz
Polar Pattern.......................................................... Cardioid X/Y Bidirectional
Sensitivity ...............................................................................18+/-0.5mV
Max SPL (0.5% THD) ........................................................................130dB
Digital Output Interface .......................................................................USB
Resolution.........................................................................................16 bit
Sampling rate .........................................................................44.1 - 48KHz
Power Requirements .........................................Power supplied from USB port
Size.........................................................................7.1” x 2” (180 x 50mm)
Weight....................................................................................5.3oz (435g)
PRECAUTIONS
• The USB-2S should never be dropped or subjected to extreme shock. Store
only in a padded case to protect it during transport.
• Keep the microphone away from extremely high temperatures (above 140°F or 60°C ) and humidity. Avoid leaving the microphone in direct sunlight for long
periods of time.
• When using the microphone outdoors, avoid prolonged exposure to moisture.
• To protect the mic cartridge and ensure the longest possible useful life, it is
highly recommended that for vocal applications, an external foam windscreen be used over the ball grille. This will prevent the buildup of saliva and perspira­tion on the cartridge diaphragm, which degrades performance and shortens the useful life of the microphone. This will also eliminate wind noise when the mic is used in a windy outdoor environment.
SERVICE
(U.S.) Should your Nady USB-2S require service, please contact the Nady Customer Ser­vice Department via telephone: (510) 652-2411 or e-mail: service@nady.com. (INTERNATIONAL) For service, please contact the Nady distributor in your country through the dealer from whom you purchased this product. The warranty card supplied with this system provides valuable warranty and service information. Store it in a safe place for future reference. Do not attempt to service this unit yourself as it will void your warranty.
Loading...