Mustek PowerMust 424 LCD, PowerMust 848 LCD, PowerMust 636 LCD Startup Manual

PowerMust 424 LCD/636 LCD/848 LCD
Line Interactive UPS
EN
1
Table of Contents
Safety Instructions
3
Package Contents & Overview
4
Installation & Initial Startup
5
Trouble Shooting
6
Specifications
7
Thank you for purchasing MUSTEK UPS. To safely operate this uninterruptible power supply system, please read and follow all instructions carefully. Read this manual thoroughly before attempting to unpack, install, or operate. You may keep this manual for further reference.
WARNUNG: Dies ist eine USV der Klasse C2. In Wohnansiedlungen kann dieses Erzeugnis Funkstörungen hervorrufen, dann muss der Benutzer zusätzliche Maßnahmen ergreifen." WARNING: This is a UPS Class C2. In residential subdivision the product may cause harmful interference, then the users have to take additional measures."
EN
2
Safety Instructions
This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the
unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs.
Internal battery voltage is 12 Vdc.  Connection to any other type of receptacle other than a two-pole, three-wire
grounded receptacle may result in shock hazard as well as violate local electrical codes.
In the event of an emergency, press the OFF button and disconnect the power cord
from the AC power supply to properly disable the UPS.
Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or
any other liquid-containing vessels on or near the unit.
This unit intended for installation in a controlled environment (temperature controlled,
indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output.  Do not attach a power strip or surge suppressor to the UPS.  Do not attach non-computer-related items, such as medical equipment, life-support
equipment, microwave ovens, or vacuum cleaners to UPS
To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.  Do not dispose of batteries in a fire as they may explode.  Do not open or mutilate the battery or batteries. Released electrolyte is harmful to
the skin and eyes. It may be toxic.
A battery can present a risk of electrical shock and high short circuit current. The
following precautions should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminals.
Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type of sealed lead-acid
battery.
This pluggable type A equipment with battery already installed by the supplier is
operator installable and may be operated by laymen.
During the installation of this equipment it should be assured that the sum of the
leakage currents of the UPS and the connected loads does not exceed 3.5 mA
Attention, hazardous through electric shock. Also with disconnection of this unit from
the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary.
The mains socket outlet that supplies the UPS shall be installed near the UPS and
shall be easily accessible.
EN
3
Package Contents
You should have received the following items inside of package:
- UPS Unit x 1
- Startup manual x 1
- Communication cable x 1
- Software CD
Overview
This compact UPS is to protect your PC data loss from power interruption. This UPS features LCD panel to display the situations of UPS unit.
Front Panel Overview:
Power switch Input voltage Output voltage AC mode indicator Load level indicator, flashing indicates
overload
Battery mode indicator Battery capacity indicator, flashing indicates
low battery
AC input Modem/Phone lineOutput receptacles x 2 USB Type B Communication port
Circuit breaker
EN
4
Installation & Initial Startup
NOTE: Before installation, please make sure nothing inside of package is
damaged. To protect your equipment from power failure, be sure that power switch must be kept in the “ON” position. Follow below steps to install your UPS unit.
Connect to Utility & Charging
Plug in the AC input cord to the wall outlet. For the best results, suggest to charge the battery at least 4 hours before initial use. The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit. CAUTION: NEVER to connect a laser printer or scanner to the UPS unit. This may cause the damage of the unit.
Turning On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch. You may check the front LED indicators for the status.
Cold Start Function
When the UPS is off and there is no power utility, its still possible to cold start the UPS unit to power the loads.
EN
5
Trouble Shooting
Problem
Possible Cause
Solutions
No words display on the front panel.
Battery voltage is too low
Charge the UPS unit up to 4 hours.
Battery failure.
Replace with the same type of battery.
Unit always on battery mode
Power cord loose
Re-plug the power cord.
Circuit breaker protected.
Press the breaker.
AC utility is too high or too low, or there is a blackout
Normal condition
When power failure, back-up time is shorten.
Overload of the UPS.
Remove some noncritical load.
Battery voltage is too low.
Charge battery 4 hours or more.
Battery defect due to high temperature operation environment, or improper operation to battery.
Replace with the same type of battery.
EN
6
Specification
MODEL
PowerMust
424 LCD
PowerMust
636 LCD
PowerMust
848 LCD
INPUT
Capacity
450VA/240W
650VA/360W
850VA/480W
Voltage
220/230/240 VAC
Voltage Range
162-290 VAC
OUTPUT
AC Voltage Regulation (Batt. Mode)
±10%
Frequency Range (Batt. Mode)
50Hz +/-1 Hz
Transfer Time
Typical 2-6 ms, 10 ms max.
Waveform (Batt. Mode)
Simulated Sine Wave
Protection
Short circuit and Overload Protection
BATTERY
Battery Type & Number
12 V/4.5 AH x 1
12 V/7 AH x 1
12 V/9 AH x 1
Typical Recharge Time
4 hours recover to 90% capacity
Protection
Discharge and Overcharge Protection
INDICATORS
LCD Display
AC mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and
Low Battery
ALARM
Battery Mode
Sounding every 10 seconds
Low Battery
Sounding every second
Overload
Sounding every 0.5 second
Battery Replacement
Sounding every 2 seconds
Fault
Continuously sounding
PHYSICAL
Dimension, DXWXH (mm)
287X100X142
Net Weight (kg)
3.55
4.25
4.9
ENVIRONMENT
Humidity
0-90 % RH @ 0- 40°C (non-condensing)
Noise Level
Less than 40dB
EN
7
PowerMust 424 LCD/636 LCD/848 LCD
Line Interaktiv USV
Anleitung zur Inbetriebnahme
DE
8
Inhaltsverzeichnis
Sicherheitshinweise
11
Lieferumfang und Ü bersicht
12
Installation und erste Inbetriebnahme
13
Problemlösungen
14
Technische Daten
15
Vielen Dank, dass Sie sich für diese USV von MUSTEK entschieden haben. Um diese unterbrechungsfreie Stromversorgung sicher zu betreiben, lesen Sie sich die folgenden Anweisungen vollständig durch, und befolgen Sie sie. Lesen Sie sich dieses Handbuch vollständig durch, bevor Sie Ihr Produkt auspacken, aufstellen und in Betrieb nehmen. Bewahren Sie dieses Handbuch für spätere Nachschlagezwecke auf.
DE
DE
Loading...
+ 19 hidden pages