MQ-D306HA — TABLE OF CONTENTS
MQ-D306HA Gasoline Powered Diaphragm Pump
Proposition 65 Warning ............................................. 2
Table of Contents ...................................................... 3
Parts Ordering Procedures .................................... 4-5
Specifications (Pump/Engine) ....................................6
Pump Dimensions ......................................................7
Safety Message Alert Symbols .............................. 8-9
Rules For Safe Operation .................................. 10-11
General Information .................................................12
Pump Components .................................................. 13
Basic Engine ............................................................14
Pre-Inspection (Engine) ...........................................15
Pre-Set-up (Pump) ............................................. 16-17
Initial Start-up (Engine) ...................................... 18-19
Maintenance (Pump) ......................................... 20-21
Maintenance (Engine)........................................ 22-23
Preparation for Long-Term Storage ......................... 24
Troubleshooting (Pump)........................................... 25
Troubleshooting (Pump/Engine) ..............................26
Explanation Of Code In Remarks Column ............... 28
Suggested Spare Parts ............................................ 29
HONDA GX120K1QX2 Engine
Air Cleaner Assembly......................................... 36-37
Camshaft Assembly ........................................... 38-39
Carburetor Assembly ......................................... 40-41
Control Assembly ............................................... 42-43
Crankcase Cover Assembly ............................... 44-45
Crankshaft Assembly ......................................... 46-47
Cylinder Barrel Assembly ................................... 48-49
Cylinder Head Assembly .................................... 50-51
Fan Cover Assembly .......................................... 52-53
Flywheel Assembly ............................................ 54-55
Fuel Tank Assembly ........................................... 56-57
Ignition Coil Assembly ........................................ 58-59
Muffler Assembly ............................................... 60-61
Piston Assembly ................................................. 62-63
Recoil Starter Assembly..................................... 64-65
Gasket Kit Assembly .......................................... 66-67
Terms and Condition Of Sale
NOTE
Parts .................... 68
As a continuing effort to update our parts book, contact the MULTIQUIP literature department for the latest revision of your "Operation and Parts Manual"
Component Drawings
Water Box and Groove Assembly ...................... 30-31
Pump Assembly ................................................. 32-35
NOTE
PAGE 4 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
Specification and part number are subject to change without notice.
Effective: June 1st, 2005
Ordering parts has never been easier!
PARTS ORDERING PROCEDURES
Choose from three easy options:
Best Deal!
Order via Internet (Dealers Only):
Order parts on-line using Multiquip’s SmartEquip website!
View Parts Diagrams
Order Parts
Print Specification Information
Goto www.multiquip.com and click on
Order Par ts
to log in and save!
Order via Fax (Dealers Only):
All customers are welcome to order parts via Fax.
Domestic (US) Customers dial:
1-800-6-PARTS-7 (800-672-7877)
Order via Phone:
Non-Dealer Customers:
Contact your local Multiquip Dealer for parts or call 800-427-1244 for help in locating a dealer near you.
If you have an MQ Account, to obtain a Username and Password, E-mail us at:
parts@multiquip.com.
To obtain an MQ Account, contact your District Sales Manager for more information.
Use the
internet
Standard orders
on complete part numbers.*
Fax
your order in and qualify for a 3% Discount
on
Standard orders
complete part numbers.*
Domestic (US) Dealers Call:
1-800-427-1244
and qualify for a 5% Discount
for all orders which include
for all orders which include
International Customers
their local Multiquip Representatives for Parts Ordering information.
Note: Discounts Are Subject To Change
Note: Discounts Are Subject To Change
should contact
When ordering parts, please supply:
❒❒
Dealer Account Number
❒❒
❒❒
Dealer Name and Address
❒❒
❒❒
Shipping Address (if different than billing address)
❒❒
❒❒
Return Fax Number
❒❒ ❒❒
Applicable Model Number
❒❒
❒❒
Quantity, Part Number and Description of Each Part
❒❒
NOTE
www.multiquip.com
Unless otherwise indicated by customer, all orders are treated as within 24 hours. We will make every effort to ship if received prior to 2PM PST.
WE ACCEPT ALL MAJOR CREDIT CARDS!
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 5
❒❒
Specify Preferred Method of Shipment:
❒❒
Fed Ex/UPS
Next Day
Stock Orders
DHL Priority One Ground
Second/Third Day
Tr u c k
Standard Orders
Air Shipments
must be noted on fax or web order form.
the same day the order is received,
and will ship
MQ-D306HA— SPECIFICATIONS (PUMP/ENGINE)
)pmuP(snoitacificepS.1elbaT
epyT
pmuP
egrahcsiD&noitcuS
eziS
pmuP
gnipmuPmumixaM
yticapaC
mgarhpaiDH603-QM
).mm67(.ni00.3
ruoh/snollag001,5
)ruoh/sretil503,91(
retemaiDsdlioS.xaM)mm83(.ni5.1
tfiLxaM)sretem26.7(.tf52
daeH.xaM)sretem42.51(.tf05
thgi
eWteNyrD
).gK27(.sbl061
)enignE(snoitacificepS.2elbaT
ledoM2XQ1K021XGADNOH
elgniS,ekorts4delooc-riA
epyT
latnoziroH,VHO,rednilyC
enignEenilosaGtfahS
XeroB
enignE
leuF
noisnemiD
)HxWxL(
yrD
teN
thgieW
ekortS
tnemecalpsiD)ni-uc2.7(cc911
tuptuOxaM.M.P.R0063/.P.H0.4
yticapaCknaTleuF)sret
yticapaCliOebuL)sretil06(.stq36.0
lortnoCdeepS
dohteM
dohteMgnitratStratSlioceR
.ni7.1x.ni4.2
)mm24xmm06(
il5.2(.lagSU66.0
elibomotuAdedaelnU
enilosaG
epyTt
hgiew-ylFlagufirtneC
.ni5.21x4.31x7.11
)mm813x143x792(
).gK31(sbl7.82
PAGE 6 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
MQ-D306HA— DIMENSIONS (PUMP)
Figure 1. MQ-D306HA Pump Dimensions
snoisnemiD.3elbaT
LEDOM
AH603-QM
A
HTGNEL
.ni0.63
).mc19(
B
C
HTDIW
.ni0.91
).mc84(
THGIEH
.ni0.72
).mc96(
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 7
MQ-D306HA— SAFETY MESSAGE ALERT SYMBOLS
FOR YOUR SAFETY AND THE SAFETY OF OTHERS!
Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.
This Owner's Manual has been developed to provide complete instructions for the safe and efficient
NOTE
Before using these pumps, ensure that the operating individual has read and understands all instructions in this manual.
SAFETY MESSAGE ALERT SYMBOLS
The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION.
DANGERDANGER
DANGER
DANGERDANGER
You WILL be NOT follow directions.
KILLED
operation of the
D306HA Diaphragm Pump.
to the engine manufacturers instructions for data relative to its safe operation.
or
SERIOUSLY
injured if you DO
MQ Model
Refer
HAZARD SYMBOLS
Potential hazards associated with the operation of the
Model D-306H, B and R Diaphragm Pumps.
with Hazard Symbols which appear throughout this manual, and will be referenced in conjunction with Safety Message Alert Symbols.
Engine exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled. NEVER operate this equipment in a confined area or enclosed structure that does not provide ample free flow air.
DANGER - Explosive Fuel Hazards
Gasoline is extremely flammable, and
its vapors can cause an explosion if ignited. DO NOT start the engine near spilled fuel or combustible fluids.
DO NOT fill the fuel tank while the engine is running or hot. DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system. Store fuel in approved containers, in well-ventilated areas and away from sparks and flames.
MQ
will be referenced
WARNING - Lethal Exhaust Gas Hazards
WARNING - Burn Hazards
WARNINGWARNING
WARNING
WARNINGWARNING
You CAN be NOT follow directions.
CAUTION
You CAN be
KILLED
CAUTIONCAUTION
CAUTION
CAUTIONCAUTION
INJURED
PAGE 8 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
or
SERIOUSLY
if you DO NOT follow directions.
injured if you DO
Engine components can generate extreme heat. To prevent burns, DO NOT touch these areas while the engine is running or immediately after operations. Never operate the engine with heat shields or heat guards removed.
WARNING - Respiratory Hazards
ALWAYS wear approved
protection when required.
respiratory
MQ-D306HA— SAFETY MESSAGE ALERT SYMBOLS
CAUTION - Rotating Parts Hazards
NEVER operate equipment with covers,
or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury.
CAUTION - Accidental Starting Hazards
ALWAYS place the power source, circuit
breakers or ON/OFF switch in the OFF position, when the generator is not in use, unless connected to transfer switch.
CAUTION - Eye and Hearing Hazards
ALWAYS wear approved eye and
hearing protection.
CAUTION - Equipment Damage Hazards
Other important messages are provided throughout this manual to help prevent damage to your light tower, other property, or the surrounding environment.
CAUTION - Read Manual
Before attempting to operate the pump, and to avoid serious injury to personnel, always read and understand operation manual. Failure to read and understand operation manual could result in serious harm or even death!
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 9
MQ-D306HA — RULES FOR SAFE OPERATION
Read this manual!
DANGERDANGER
DANGER
DANGERDANGER
Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.
The following safety guidelines should always be used when operating the
GENERAL SAFETY
DO NOT operate or service this equipment before reading this entire manual.
This equipment should not be operated by persons under 18 years of age.
NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.
MQ Model D-306H Diaphragm Pump.
NEVER touch the hot exhaust
manifold, muffler or cylinder. Allow these parts to cool before servicing engine or mixer.
High Temperatures – Allow the engine to cool before adding fuel or performing service and maintenance functions. Contact with serious burns.
The engine section of this mixer requires an adequate free flow of cooling air. enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the mixer or engine and may cause injury to people. Remember the pump's engine gives off carbon monoxide gas.
NEVER
DEADLY
hot!
components can cause
operate the mixer in any
ALWAYS refuel in a well-ventilated area, away from sparks and open flames.
NEVER operate this equipment when not feeling well due to fatigue, llness or taking medicine.
NEVER operate this equipment under the influence of
ALWAYS wear proper respiratory (mask), hearing and eye protection equipment when operating the mixer.
NEVER place hands inside the drum while the blades are rotating.
Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.
Manufacture does not assume responsibility for any accident due to equipment modifications.
drugs
or
alcohol
.
ALWAYS use extreme caution when working with flammable liquids. When refueling, stop the engine and allow it to cool. DO NOT machine. Fire or explosion could result from fuel vapors, or if fuel is spilled on a hot engine.
NEVER operate the pump in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe
harm or even death.
Topping-off to filler port is dangerous, as it tends to spill fuel.
Maintain this equipment in a safe operating condition at all times.
ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.
smoke
around or near the
bodily
NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.
PAGE 10 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
MQ-D306HA — RULES FOR SAFE OPERATION
ALWAYS be sure the operator is familiar with proper safety
precautions and operation techniques before using pump.
NEVER leave the pump unattended, turn off engine when
unattended.
NEVER pump volatile, explosive, flammable or low flash point fluids. These fluids could ignite or explode.
NEVER operate the pump in an
Keep all
inexperienced
explosive
and
unauthorized
atmosphere.
people away
from the equipment at all times.
Before starting the pump, check that the clean-out cover is securely fasten.
ALWAYS ensure pump is on level ground before use.
Become familiar with the components of the pump before operating.
ALWAYS replace any worn or damaged warning decals.
NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.
NEVER open the priming plug when pump is hot. Hot water
inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug.
TRANSPORTING
MAINTENANCE
EMERGENCIES
ALWAYS shutdown engine before transporting. Tighten fuel tank cap securely and close fuel cock to
prevent fuel from spilling. Drain fuel when transporting pump over long distances
or bad roads.
NEVER lubricate components or attempt service on a running pump.
ALWAYS allow the pump a proper amount of time to cool before servicing.
Keep the pump in proper running condition. Fix damage to the pump immediately and always replace
broken parts. Dispose of hazardous waste properly. Examples of
potentially hazardous waste are used motor oil, fuel and fuel filters.
DO NOT use food or plastic containers to dispose of hazardous waste.
ALWAYS know the location of the nearest
extinguisher
and first aid kit.
fire
NEVER open the pump housing during operation or start the
pump with the clean-out cover removed. The rotating impeller inside the pump can cut or sever objects caught in it.
NEVER block or restrict flow from discharge hose. Remove
kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.
ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump.
In
winter
drain water from pump housing to prevent freezing.
ALWAYS test the engine
ON/OFF
switch before operating.
The purpose of this switch is to shut down the engine .
Refer to the
HONDA Engine Owner's Manual
for engine technical questions or information recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.
In emergencies nearest phone or
always
know the location of the
keep a phone on the job site
.
Also know the phone numbers of the nearest
ambulance, doctor
and
fire department
. This information will be invaluable in the case of an emergency.
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 11
MQ-D306HA — GENERAL INFORMATION
APPLICATION
MQ Model D305HA diaphragm
The
pump is designed to be used for de-watering applications. The suction and discharge ports on this pump
use a 3-inch diameter opening, which allows the pump to pump at rate of approximately 5,100 gallons/hour (gph) or 19,305 liters/hour (lph).
Diaphragm pumps use a positive displacement design rather than centrifugal force to move water through the casing. This means the pump will deliver a specific amount of flow per stroke, revolution or cycle. These pumps are commonly referred to as mud hogs, mud hens and mud suckers. Their names reflect their
Elevation
Higher elevations will effect the performance of the pump. Due to less atmospheric pressure at higher altitudes, pumps DO NOT have the priming ability that they have at sea level. This is due to the “thinner air” or lack of oxygen at higher altitudes.
A general rule of thumb is that for every 1,000 feet of elevation above sea level a pump will lose one foot of priming ability.
For example, in Flagstaff, Arizona where the elevation is approximately 7,000 feet, the pump would have a suction lift of only 18 feet rather than the 25 feet at sea level. Table 3 shows suction lift at various elevations.
popularity for use in applications where shallow depths and slurry water render centrifugal pumps ineffective
Power Plant
This diaphragm pump is powered by a 5.5 horsepower air cooled, 4-stroke, single cylinder, incorporates a low "
Oil Alert Feature
HONDA GX-120 gasoline engine that
" . The drive shaft of the
leveLaeS)840.3(0.01)275.4(0.51)690.6(0.02)026.7(0.52
,2)086.2(08.8)320.4(2.31)463.5(6.71)507.6(0.22
engine is coupled to an offset connecting rod that is coupled to a flexible diaphragm. The connecting rod alternately raises
000,6)301.2(09.6)961.3(4.01)602.4(8.31)372.5(3.71
(expands) and lowers (contracts) the diaphragm at a rate between 40 and 65 strokes per minute depending on engine speed.
,3(000,01)737.1(07.5)126.2(06.8)474.3(4.11)853.4(3.41
edutitlA
)sreteM(teeF
)016(000
)912,1(000,4)773.2(08.7)665.3(7.11)457.4(6.51)349.5(5.91
)928,1(
)834,2(000,8)988.1(02.6)438.2(03.9)977.3(4.21)427.4(5.51
)840
snoitavelEsuoiraVtatfiLnoitcuS.3elbaT
)sreteM(teeFnitfiLnoitcuS
Oil Alert Feature
In the event of
low oil
or
no oil
, the HONDA GX-120 engine has
Table 4 shows percentage drops in performance as elevation
increases. a built-in oil alarm engine shut-down feature. In the event the oil level is low the engine will automatically shut-down.
Suction Lift
This pump is intended to be used for dewatering applications and is capable of suction lifts up to 25 feet at sea level. For optimal suction lift performance keep the suction hose or line as short as possible. In general always place the pump as close to the water as possible.
Pump Support
The pump should always be placed on
solid stationary ground
in a level position.
NEVER place the pump on
soft soil
. The suction hose or pipe connection should always be checked for tightness and leaks. A small suction leak in the hose or fittings could prevent the pump from priming.
NOTE
suoiraVtassoLecnamrofreP.4elbaT
snoitavelE
edutitlA
sreteM(teeF
leveLaeS%001%001
)016(000,2%79%59
)912,1(000,4%59%19
)928,1(000,6%3
)834,2(000,8%19%38
)840,3(000,01%88%87
9%78
Please contact your nearest authorized MQ dealer for any accessories that your pump may require.
wolFegrahcsiDdaeHegrahcsiD
PAGE 12 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
MQ-D306HA — PUMP COMPONENTS
Figure 2 shows a typical application using the MQ D306HA series diaphragm pump. Please note that this pump is intended for the removal of clean water and water containing some debris and solids. Maximum size of solids should not exceed 1.5 inch (38 mm) in diameter. DO NOT set strainer on bottom of water bed. Placing the strainer above the water bed will prevent the pump from drawing in excessive amounts of sand and foreign debris.
NOTE
1. Pump – The MQ D306HA is a 3-inch diaphragm pump that is used in general de-watering applications. Typical dewatering applications consist of cleaning out cesspools and septic tanks, draining slow seepage from small excavations, trenches and construction sites, or pumping out industrial waste.
2. Fill Cap – Prior to operation, the pump casing should be filled with water. Remove this cap to add water to the pump. After the initial prime, a sufficient amount of water will be retained in the casing so that the operator will not need to re-prime later.
If the casing is dry or has insufficient water, the pump will have difficulty in priming which could lead to premature mechanical seal wear thus causing damage to the pump.
3. Discharge Port – Connect a 3-inch discharge hose to this port. Use two worm clamps to secure the hose.
Contact your nearest Multiquip dealer for quick disconnect hoses and fittings.
4. Worm Clamp – Used to secure the hose to the inlet and
5. Discharge Hose – Connect a flexible rubber hose to the
6. Suction Port – Connect a 3-inch inlet hose to this port.
7. Suction Hose – Connect a flexible rubber hose to the
8. Strainer – Always attach a strainer to bottom side of the
9. Support Body – This unit is equipped with a hinged
Figure 2. MQ-D306HA Pump Application
outlet ports on the pump. Use two clamps to secure the hose on the inlet side of the pump.
discharge port on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type discharge hose. Contact Multiquip parts department for ordering information.
Use two worm clamps to secure the hose.
suction port on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type suction hose. Contact Multiquip parts department for ordering information
suction hose to prevent large objects and debris from entering the pump. Strainer should be positioned so that it will remain completely under water. Running the pump with the strainer above water for long periods can damage pump.
support assembly, that allows for easy access to the pump body.
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 13
Figure 3. Engine Controls and
Components
MQ-D306HA — BASIC ENGINE
INITIAL SERVICING
The engine (Figure 3) must be checked for proper lubrication and filled with fuel prior to operation. Refer to the Honda manufacturers engine manual for instructions and details for operation and servicing.
1. Fuel Filler Cap – Remove this cap to add unleaded gasoline to the fuel tank. Make sure cap is tightened securely. DO NOT over fill.
Explosive FuelExplosive Fuel
Explosive Fuel
Explosive FuelExplosive Fuel
DANGER - Explosive Fuel
Adding fuel to the tank should be done only when the engine is stopped and has had an opportunity to cool down. In the event of a fuel spill, DO NOT attempt to start the engine until the fuel residue has been completely wiped up, and the area surrounding the engine is dry.
2. Throttle Lever – Used to adjust engine RPM speed (lever
SLOW
advanced forward
FAST
).
3. Engine ON/OFF Switch – ON position permits engine starting, OFF position stops engine operations.
4. Recoil Starter (pull rope) – Manual-starting method. Pull the starter grip until resistance is felt, then pull briskly and smoothly.
, lever back toward operator
6. Choke Lever – Used in the starting of a cold engine, or in cold weather conditions. The choke enriches the fuel mixture.
7. Air Cleaner – Prevents dirt and other debris from entering the fuel system. Remove wing-nut on top of air filter cannister to gain access to filter element.
NOTE
8. Spark Plug – Provides spark to the ignition system. Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean spark plug once a week.
9. Muffler – Used to reduce noise and emissions.
CAUTION - Burn Hazard
Engine components can generate extreme heat. To prevent burns, DO NOT touch these areas while the engine is running or immediately after operating. NEVER operate the engine with the muffler removed.
5. Fuel Valve Lever – OPEN to let fuel flow, CLOSE to stop the flow of fuel.
10. Fuel Tank – Holds unleaded gasoline. For additional information refer to engine owner's manual.
Operating the engine without an air filter, with a damaged air filter, or a filter in need of replacement will allow dirt to enter the engine, causing rapid engine wear.
PAGE 14 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
CAUTION - Read Manual
Please read the entire maintenance section in this manual before servicing the pump. In addition for operator safety, please read all safey messages at the begining of the manual
MQ-D306HA — PRE-INSPECTION (ENGINE)
Inspection
1. Clean the pump, removing dirt and dust, particularly the engine cooling air inlet, carburetor and air cleaner.
2. Check the air filter for dirt and dust. If air filter is dirty, replace air filter with a new one as required.
3. Check carburetor for external dirt and dust. Clean with dry compressed air.
4. Check fastening nuts and bolts for tightness.
Engine Oil Check
1. To check the engine oil level, place the pump on secure level ground with the engine stopped.
2. Remove the filler dipstick from the engine oil filler hole (Figure 4) and wipe clean.
Motor fuels are highly flammable and can be dangerous if mishandled. DO NOT smoke while refueling.
should be done only when the engine is stopped and has had an opportunity to cool down. DO NOT attempt to refuel the pump if the engine is
hot! or running
immediately.
fuel residue has been completely wiped up, and the area surrounding the engine is dry.
Figure 5. Engine Oil Dipstick (Oil Level)
epyTliO.5elbaT
nosaeS erutarepmeT epyTliO
remmuS rehgiHroC°52 03-W01EAS
llaF/gnirpS C°01~C°52 02/03-W01EAS
retniW rewoLroC°0 01-W01EAS
DANGER - Explosive Fuel
Adding fuel to the tank
In the event of any spilled fuel, wipe up
DO NOT attempt to start the engine until the
Fuel Check
Figure 4. Engine Oil Dipstick (Removal)
3. Insert and remove the dipstick without screwing it into the filler
neck. Check the oil level shown on the dipstick.
4. If the oil level is low (Figure 5), fill to the edge of the oil filler
hole with the recommended oil type (Table 5). Maximum oil capacity is .63 quarts (.60 liters)
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 15
1. Remove the gasoline cap located on top of fuel tank.
2. Visually inspect to see if the fuel level is low. If fuel is low, replenish with unleaded fuel.
3. When refueling, be sure to use a strainer for filtration. DO
NOT top-off fuel. Wipe up any spilled fuel
immediately!
Before Starting:
CAUTION - General Safety Precautions
NEVER operate the pump in a confined
area or enclosed area structure that does not provide ample
free flow of air
.
MQ-D306HA — PRE-SETUP (PUMP)
rigid
3. Remember suction hoses must be collapse when the pump is in operation.
4. Check that
Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.
the
discharge
hose (Figure 2) is not restricted.
enough not to
ALWAYS wear approved eye and hearing protection before operating the compactor.
Before Starting
1. Read safety instructions at the
beginning of manual.
2. Place pump as near to water as possible, on a firm flat, level surface.
3. To prime pump, remove fill cap (Figure 2) and fill pump casing with water. If the pump casing is not filled with water before starting, it will not begin pumping.
CAUTION - Pump Casing
Pump casing
must
be filled with water before using
5. The discharge hose is usually a
6. Make sure the
The strainer should be positioned so it will remain completely
under water
water for long periods can damage the pump.
pump. Otherwise pump will not be able to begin pumping.
DO NOT pump flammable fluids, corrosive chemicals or fluids
WARNING - Fill Cap
DO NOT open
fill cap
if pump is hot! Water inside may
containing toxic substances. These fluids can create potentially dangerous health and environmental hazards. Contact local authorities for assistance.
be under pressure.
Suction and discharge hoses are
NOTE
available from Multiquip. Contact your nearest dealer for more information.
collapsible
hose, however if a thin-walled discharge hose is not avail­able, a rigid suction hose can be substituted in its place.
suction strainer
securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled into the pump.
(Figure 2) is clean and
(thin-walled)
CAUTION - Strainer
. Running the pump with the strainer above
CAUTION - Flammable Fluids
4. Check for between the pump and engine housing, the seal inside the pump may be worn or damaged. Continued operation of the pump is not recommended. Further usage of the pump under these conditions may cause severe water damage to engine.
Hoses and Clamps
1. Check that all hoses are Make certain suction hose (Figure 2) does not have any air leakage. Tighten hose clamps and couplings as required.
2. It is recommended that 2 clamps be used when securing the suction hose to the inlet side (suction) of the pump.
leaks
between pump and engine. If water is leaking
This pump uses a water-cooled water from seeping into the engine. The passage of water through the pump casing lubricates the seal and prevents it from overheating. in the casing as this will cause damage to the mechanical
securely
PAGE 16 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
attached to the pump.
seal.
CAUTION - Mechanical Seal
mechanical seal
NEVER!
operate the pump without water
to prevent
MQ-D306HA — PRE-SETUP (PUMP)
Gear Reduction Oil (Transmission)
1. Remove the transmission oil level plug (Figure 6). If oil
begins to seep out as the plug is being removed, then it can be assumed that the transmission oil is at the proper operating level.
2. If oil does not seep out as the oil level plug is being removed,
then remove the transmission oil fill plug and fill with
SAE 80/90
Transmission oil capacity is capacity is 1-1/4 pints (590 ml.).
EP gear oil
to the proper operating level.
Connecting Rod Bearing Lubrication
1. Grease connecting rod bearing thru the access hole (Figure 7) every 25 hours of operation.
2. Use only NLG1 Grade #2 consistency.
premium lithium based grease
, conforming to
NOTE
Figure 6. Transmission Oil Level
Diaphragm pumps will handle fluids containing considerable solids (not to exceed 1.5 inch/28 mm), however, if the mixture is too heavy to be pumped, water must be added until the mixture becomes sufficiently fluid for pumping.
Figure 7. Connecting Rod Bearing Lubrication
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 17
MQ-D306HA— INITIAL START-UP (ENGINE)
CAUTION - Read Manual
DO NOT attempt to operate the pump until the
Safety, General Information and Inspection sections of this manual have been
thoroughly understood
This section is intended to assist the operator with the
start-up
this section be read carefully before attempting to use the pump in the field.
Starting the Engine (
1. Place the engine
of the diaphragm pump. It is extremely important that
position.
Figure 8. Engine Fuel Valve Lever (ON Position)
.
HONDA
fuel valve lever
read and
initial
engine)
(Figure 8) to the "ON"
4. Place the if starting a
5. Place the position.
choke lever
warm engine
Figure 11. Engine Choke Lever (Closed)
engine ON/OFF switch
(Figure 9) in the "CLOSED " position
or the
temperature is warm.
(Figure 12) in the "ON "
2. Move the position, about 1/3 of the way toward the fast position.
3. Place the starting a
throttle lever
Figure 9. Throttle Lever (1/3 Start Position)
choke lever
cold
engine.
(Figure 9) away from the slow
(Figure 10) in the "OPEN " position if
Figure 12. Engine ON/OFF Switch (ON Position)
6. Grasp the starter grip (Figure 13) and slowly pull it out. The resistance becomes the hardest at a certain position, corre­sponding to the compression point. Pull the starter grip briskly and smoothly for starting.
Figure 13. Starter Grip
Figure 10. Engine Choke Lever (Open)
PAGE 18 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
MQ-D306HA— INITIAL START-UP (ENGINE)
7. If the engine has started, slowly return the choke lever (Figure 14 ) to the “CLOSED” position. If the engine has not started repeat steps 1 through 6.
Figure 14. Choke Lever (Closed)
8. Before the pump is placed into operation, run the engine for several minutes. Check for fuel leaks, and noises that would associate with a lose component.
Stopping The Engine
Normal Shutdown
1. Move the throttle lever to the IDLE position (Figure 16) and run the engine for three minutes at low speed.
2. After the engine “OFF” position (Figure 17).
Figure 16. Throttle Lever (Idle)
cools
, turn the engine ON/OFF switch to the
To begin pumping, place the throttle lever (Figure 15) in the
9.
"RUN" position.
3. Place the position.
Figure 15. Throttle Lever (Run)
Emergency Showdown
Pump speed can be
NOTE
can be determined by trying to pump at several speeds. Limit maximum speed to 65 strokes per minute of the diaphragm (2,800 RPM engine speed).
the engine throttle control from full volume, 65 strokes per minute, to about 40 strokes per minute for lesser volume. Smoothest operation
regulated
1. Move the throttle lever quickly to the “IDLE
with
place the engine ON/OFF switch in the “OFF” position.
Figure 17. Engine ON/OFF Switch (OFF)
fuel shut-off lever
Figure 18. Fuel Valve Lever (OFF)
(Figure 18) in the ”OFF
position, and
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 19
MQ-D306HA — MAINTENANCE (PUMP)
Pump Vacuum Test
Pump Cleaning
After pumping water containing large amounts of dirt and
CAUTION - Priming Pump
DO NOT attempt to start the engine unless the pump has
previously been will occur if pump has not been primed.
primed
with water. Severe pump damage
debris, perform the following:
1. Remove the drain plug from the pump housing (Figure 2) and drain any water left in the pump.
3. Clean and remove dirt, debris from pump casing. Inspect impeller and volute for wear. Replace any damaged or
To perform the pump vacuum test do the following:
1. Remove the pump fill cap (Figure 2), and fill the pump with water.
2. Start the engine as outlined in the initial start-up section, and wait for the pump to begin pumping.
3. As shown in Figure 19 (next page), place a water hose inside the discharge opening of the pump, and turn on the water. This flow of water into the discharge opening will
prevent
4. Place the
the pump from running dry.
Pump Vacuum Tester
(P/N 7000030) over
worn parts.
Gear Reduction Oil (Transmission)
1. Change transmission oil after the first operation. Use SAE 80/90 capacity is 1-1/4 pints (590 ml.). Check oil level periodically and change oil after every
Connecting Rod Bearing Lubrication
1. Grease connecting rod bearing thru the access hole (Figure 7) every 25 hours of operation.
2. Use only NLG1 Grade #2 consistency.
the pump suction (inlet) opening (Figure 19) with the vacuum gauge facing upwards. It may be necessary to apply a small amount of water around the rubber seal of the vacuum tester to make a good suction fit.
5. Check and make sure that there are no air leaks between the vacuum tester and the inlet port on the pump. If air
Connecting Rod Bearing Lubrication
1. Keep interior of pump and valves clean. Flush out pump with clear water after operation.
2. Remove connecting rod guard occasionally and wipe up excess grease from connecting rod bearing.
leaks are present reseat vacuum tester.
40 hours
EP gear oil.
400 hours
premium lithium based grease
Transmission oil
of operation.
, conforming to
of
6. Run the pump for a few minutes while monitoring the vacuum gauge. If the gauge indicates a reading between
-25 and -20 in. Hg. (inches of mercury) then it can be assumed that the pump is working correctly.
25 in. Hg (inches of mercury)
NOTE
translates into 25 feet of lift at
level
.
sea
7. If the vacuum tester gauge indicates a reading
below
-20 in. Hg, it can then be assumed that the pump is not functioning correctly, and corrective action needs to be taken.
6. To test the
flapper valve
, shut down the engine. The vacuum tester should remain attached to the pump suction inlet port by vacuum. This indicates the pump's flapper valve is seating properly to hold water in the suction hose when the engine is stopped. This prevents backflow and allows for faster priming when the engine is restarted.
PAGE 20 — MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL — REV. #3 (01/09/07)
MQ-D306HA — MAINTENANCE (PUMP)
Figure 19. Pump Vacuum Tester
NOTE
MQ-D306HA DIAPHRAGM PUMP — OPERATION AND PARTS MANUAL— REV. #3 (01/09/07) — PAGE 21
Pressure reading may vary depending on altitude. See Tables 3 and 4.