Multi-Contact MA250 User Manual

Advanced Contact Technology
MA000 (de_en)
MA250 (it_en) Montageanleitung
Istruzioni per il montaggio
Indice
Istruizoni per la sicurezza ............................................................2
Esempio di connessione in parallelo .........................................3
Angolo di curvatura del cavo .....................................................3
MA000 (de_en)
MA250 (it_en) Assembly instructions
Assembly instructions
PV Branch plug PV-AZS4 PV Branch socket PV-AZB4
Content
Safety Instructions ......................................................................2
Example of parallel connections ................................................3
Cable routing .............................................................................3
PV-AZS4 PV-AZB4
www.multi-contact.com 1 / 4
Advanced Contact Technology
Istruzioni per la sicurezza Safety Instructions
I prodotti possono essere montati e installati solo da esperti qualifi cati e formati, rispettando tutte le disposizioni di sicurez- za e le norme di legge applicabili. Multi-Contact (MC) declina qualsiasi responsabilità derivante dal mancato rispetto delle presenti avvertenze.
Utilizzare esclusivamente i pezzi e gli attrezzi indicati da MC. Rispettare sempre le procedure qui descritte per la preparazi­one e il montaggio, poiché in caso contrario non potranno es­sere garantiti né la sicurezza né il rispetto delle caratteristiche tecniche indicate. Non apportare in nessun modo modifi che al prodotto.
I connettori non di fabbricazione MC, che possono essere col­legati con elementi MC e che a volte sono indicati dal produt­tore come “compatibili con MC“, non soddisfano i requisiti per un collegamento elettrico sicuro e stabile nel tempo e, per motivi di sicurezza, non possono essere collegati con elementi MC. MC declina quindi qualsiasi responsabilità nel caso in cui questi connettori non autorizzati da MC vengano collegati con elementi MC e causino quindi dei danni.
I lavori qui descritti non possono essere eseguiti su pezzi sotto tensione o corrente.
La protezione da scosse elettriche deve essere ga­rantita nel prodotto fi nale e accertata dall’utente.
I connettori non possono essere staccati sotto cari­co. È consentito collegare e staccare i connettori sotto tensione.
I connettori sono impermeabili in conformità con la
classe di protezione IP, ma non sono idonei all’uso prolungato sott‘acqua. Non mettere il connettore a diretto contatto con la copertura del tetto.
Proteggere i connettori non utilizzati da umidità e
sporco con una capsula di chiusura (MC4 codice
32.0716 per prese e 32.0717 per spine). I connettori sporchi non possono essere collegati tra loro.
MC consiglia di non utilizzare né cavi in PVC né cavi
non stagnati del tipo H07RN-F.
The products may be assembled and installed only by suitably qualifi ed and trained specialists with due observance of all ap- plicable safety regulations. Multi-Contact (MC) declines any liability in the event of failure to observe these warnings.
Use only the components and tools specifi ed by MC. Do not deviate from the preparation and assembly procedures descri­bed here, since in this event, in the event of self-assembly, no guarantee can be given as to safety or conformity with the technical data. Do not modify the product in any way.
Connectors not made by MC which can be mated with MC elements and in some cases are also described as ”MC-com­patible” do not conform to the requirements for safe electri­cal connection with long-term stability, and for safety reasons must not be plugged together with MC elements. MC can therefore accept no liability for damage which occurs as a re­sult of mating these connectors which lack MC approval with MC elements.
The work described here must not be carried out on live or load-carrying parts.
Protection from electric shock must be assured by the end product and its user.
The plug connections must not be disconnected under load. Plugging and unplugging when live is permitted.
The plug connectors are watertight in accordance
with IP protection class. However, they are not suitable for continuous operation under water. Do not place the plug connectors directly on the roof membrane.
Unmated plug connectors must be protected from
moisture and dirt with a sealing cap (MC4 Article No. 32.0716 for sockets and 32.0717 for plugs). The male and female parts must not be plugged together when soiled.
MC does not recommend the use of either PVC
cables or untinned cables of type H07RN-F.
Ulteriori caratteristiche tecniche sono indicate nel
catalogo del prodotto.
For further technical data please see the product
catalogue.
Spiegazione dei simboli Explanation of the symbols
Pericolo! Voltaggi pericolosi
Pericolo! Area pericolosa Warning of a hazard area
Consiglio utile Useful hint or tip
2 / 4 www.multi-contact.com
Warning of dangerous voltages