MSI MS-95Q6 Schematic 0624

Page 1
5
4
3
2
1
MS-95Q6
D D
REV:0D 2008 05/21
01 COVER 02 1U Boards Connction 03 JFAN_MB1 04 FAN1-FAN7 05 CPLD
C C
06 SAS Connector 07 DSD 08 LED 09 Power Connector & MISC
B B
MICRO-STAR
MICRO-STAR
A A
5
4
3
MICRO-STAR Title
Title
Title
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
COVER 0D
COVER 0D
COVER 0D
Date: Sheet
Date: Sheet
Date: Sheet
2
of
19Tuesday, June 24, 2008
of
19Tuesday, June 24, 2008
of
19Tuesday, June 24, 2008
1
Page 2
5
1U Bords Connection
4
3
2
SATA Header
7654321
1 GND 2 TX+ 3 TX­4 GND 5 RX­6 RX+ 7 GND
1
D D
9197
MiniSAS1
JFP1
POWER
JFL1
JFR1
STATA1
JSGPIO1
JUSB1
STATA2
JUSB2
S8 S9 S10 S11 S12 S13 S14
S1 S2 S3 S4 S5 S6 S7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
S1 GND S2 TX+ S3 TX­S4 GND S5 RX­S6 RX+ S7 GND
SAS Connector
SAS HDD
CPU1 CPU2
C C
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
95Q6
JPWR1
JSGPIO1
JFAN1
JFAN_MB
JFAN2 JFAN3
JFAN4 JFAN5 JFAN6
SATA0 SATA1 SATA2
SASC0
SASC1
JFAN7
SASC2
S14 S13 S12 S11 S10 S9 S8
S7 S6 S5 S4 S3 S2 S1
S1 GND S2 RX+ S3 RX­S4 GND S5 TX­S6 TX+ S7 GND
SATA HDD
JFAN1 JFAN2
B B
95Q5
JFAN_MB1
JFR1
JSGPIO1
JPWR1
SASC0
SASC1
JFAN3 JFAN4 JFAN5 JFAN6
SASC2
MiniSAS1
MiniSAS2
SASC3
SASC4
SASC5
JFAN7
7654321
S1 GND S2 RX+ S3 RX­S4 GND S5 TX­S6 TX+ S7 GND
95T2
VGA1
A A
5
JFP1
USB1 USB2
4
UEB2
LED1
LED2
LED3
BTN3
BTN1
BTN2
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
MS-95Q6
MS-95Q6
MS-95Q6
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
1U Boards Connction(1) 0D
1U Boards Connction(1) 0D
1U Boards Connction(1) 0D
Date: Sheet of
Date: Sheet of
3
2
Date: Sheet of
1
29Tuesday, June 24, 2008
29Tuesday, June 24, 2008
29Tuesday, June 24, 2008
Page 3
5
JFANSEL1_1-2
JFANSEL1_1-2
JUMPER-1X2A_GREEN-RH-1
JUMPER-1X2A_GREEN-RH-1
JFANSEL1
JFANSEL1
R196 10KR0402R196 10KR0402
1 2
R213 51R0402R213 51R0402
D D
3
H1X3M_BLACK-RH-2
H1X3M_BLACK-RH-2
J_FANSEL1 FAN Select
1-2
Non Option Fan
2-3
Full Fan
C C
4
JFANSEL2_1-2
JFANSEL2_1-2
JUMPER-1X2A_GREEN-RH-1
JUMPER-1X2A_GREEN-RH-1
R75
R75
JFANSEL2
JFANSEL2
X_4.7KR0402
X_4.7KR0402
X_4.7KR0402
X_4.7KR0402
R76
R76
1 2 3
H1X3M_BLACK-RH-2
H1X3M_BLACK-RH-2
Jumper(1-2)Jumper(1-2)
J_FANSEL2 FAN Select
1-2 2-3
VCC3VCC3
R195 10KR0402R195 10KR0402
FAN_SELECT2FAN_SELECT1
R212 51R0402R212 51R0402
Non Option Fan Full Fan
NEC REQUEST
R77
R77
X_4.7KR0402
X_4.7KR0402
R78
R78
X_4.7KR0402
X_4.7KR0402
3
OC CHANGE
FANTACH1_M4
FANTACH1_BAK4
FANTACH2_M4
FANTACH2_BAK4
FANTACH3_M4 FANTACH3_BAK4 FANTACH4_M4
FANTACH4_BAK4
FANTACH5_M4
FANTACH5_BAK4
FANTACH6_M4
FANTACH6_BAK4
FANTACH7_M4
FANTACH7_BAK4
2
FANTACH1_M FANTACH1_BAK FANTACH2_M FANTACH2_BAK FANTACH3_M FANTACH3_BAK FANTACH4_M FANTACH4_BAK FANTACH5_M FANTACH5_BAK FANTACH6_M FANTACH6_BAK FANTACH7_M FANTACH7_BAK FANTACH8_M
BHEAD2X15_2MM_NP30
BHEAD2X15_2MM_NP30
1U_2U_SEL
1U 0 2U 1
JFAN_MB1
JFAN_MB1
1 2 3 5
9 11 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
FAN_SELECT1 FAN_SELECT2
4 6 87
FPWM_CPU
10
FPWM_DIMM
12
FPWM_PWR
14
SMB_HWM_3V3SB_CLK SMB_HWM_3V3SB_DAT
1U_2U_SEL
R82
R82 X_0R
X_0R
VCC3
R80 0RR80 0R
1
NC for 2U BP
ATX_PG
R810R R810R
NEC REQUEST
ATX_PG 5
OC CHANGE
U83
VCC3
R65
R65
10KR0402
10KR0402
FAN_F5_N_M FAN_F5_BAK_N
U83
1
SCL
2
SDA
3
A0
4
A1
5
A2
6
I/O0
7
I/O1
8
VSS
SMBUS ADDR: 0X30
1 2
U84
U84
1
SCL
2
SDA
3
A0
4
A1
5
A2
6
I/O0
7
I/O1
8
VSS
R124 0RR124 0R R125 0RR125 0R R126 0RR126 0R R127 0RR127 0R
R128 0RR128 0R R129 0RR129 0R
R130 0RR130 0R
FPWM3 FPWM4 FPWM5 FPWM6
FPWM2 FPWM7
FPWM1
FPWM3 5 FPWM4 5 FPWM5 5 FPWM6 5
FPWM2 5 FPWM7 5
FPWM1 5
SMB_HWM_3V3SB_CLK SMB_HWM_3V3SB_DAT
FAN_F1_N_M8
FAN_F1_BAK_N8
FAN_F1_N_M FAN_F1_BAK_N
FPWM_CPU
FPWM_DIMM
FPWM_PWR
0B CHANGE
B B
SMB_HWM_3V3SB_CLK SMB_HWM_3V3SB_DAT
FAN_F5_N_M8
FAN_F5_BAK_N8
SMBUS ADDR: 0X32
A A
5
4
3
2
VCC3
16
VDD
15
RESET
14
I/O7
13
I/O6
12
I/O5
11
I/O4
10
I/O3
9
I/O2
PCA9557PW-T_TSSOP16-RH
PCA9557PW-T_TSSOP16-RH
VCC3
16
VDD
15
RESET
14
I/O7
13
I/O6
12
I/O5
11
I/O4
10
I/O3
9
I/O2
PCA9557PW-T_TSSOP16-RH
PCA9557PW-T_TSSOP16-RH
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
MS-95Q6
MS-95Q6
MS-95Q6
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
J1 & JCD1 0D
J1 & JCD1 0D
J1 & JCD1 0D
Date: Sheet
Date: Sheet
Date: Sheet
FAN_F4_BAK_N FAN_F4_N_M FAN_F3_BAK_N FAN_F3_N_M FAN_F2_BAK_N FAN_F2_N_M
FAN_F7_BAK_N FAN_F7_N_M FAN_F6_BAK_N FAN_F6_N_M
R131
R131
4.7KR0402
4.7KR0402
FAN_F4_BAK_N 8 FAN_F4_N_M 8 FAN_F3_BAK_N 8 FAN_F3_N_M 8 FAN_F2_BAK_N 8 FAN_F2_N_M 8
FAN_F7_BAK_N 8 FAN_F6_BAK_N 8
FAN_F7_N_M 8 FAN_F6_N_M 8
NEC REQUEST
1
OC CHANGE
of
39Tuesday, June 24, 2008
of
39Tuesday, June 24, 2008
of
39Tuesday, June 24, 2008
Page 4
5
R12 0RR12 0R
FPWM1_FAN
FPWM1_FAN5
NEC REQUEST
OC CHANGE
D D
R9 0RR9 0R
FPWM2_FAN
FPWM2_FAN5
NEC REQUEST
OC CHANGE
R70 0RR70 0R
FPWM3_FAN
FPWM3_FAN5
NEC REQUEST
C C
FPWM4_FAN
FPWM4_FAN5
NEC REQUEST
FPWM5_FAN
FPWM5_FAN5
NEC REQUEST
B B
FPWM6_FAN
FPWM6_FAN5
NEC REQUEST
FPWM7_FAN5
FPWM7_FAN
NEC REQUEST
A A
OC CHANGE
R71 0RR71 0R
OC CHANGE
R72 0RR72 0R
OC CHANGE
R73 0RR73 0R
OC CHANGE
R10RR1
0R
OC CHANGE
FANTACH3_B
FANTACH3
FANTACH4_B
FANTACH4
FANTACH7_B
FANTACH7
VCC12 VCC12
JFAN1
JFAN1
1
FANTACH1_B
FANTACH1
FANTACH2_B
FANTACH2
FANTACH5_B
FANTACH5
FANTACH6_B
FANTACH6
2 3 4 5 6 7 8
C4
BH1X8-1.25PITCH_NATURE-RH
BH1X8-1.25PITCH_NATURE-RH
C10u16Y1206C4C10u16Y1206
VCC12
JFAN2
JFAN2
1 2 3 4 5 6 7 8
C3
BH1X8-1.25PITCH_NATURE-RH
BH1X8-1.25PITCH_NATURE-RH
C10u16Y1206C3C10u16Y1206
VCC12 VCC12
JFAN3
JFAN3
1 2 3 4 5 6 7 8
C6
BH1X8-1.25PITCH_NATURE-RH
BH1X8-1.25PITCH_NATURE-RH
C10u16Y1206C6C10u16Y1206
VCC12
JFAN4
JFAN4
1 2 3 4 5 6 7 8
C7
BH1X8-1.25PITCH_NATURE-RH
BH1X8-1.25PITCH_NATURE-RH
C10u16Y1206C7C10u16Y1206
VCC12
JFAN5
JFAN5
1 2 3 4 5 6 7 8
BH1X8-1.25PITCH_NATURE-RH
BH1X8-1.25PITCH_NATURE-RH
C8
C10u16Y1206C8C10u16Y1206
VCC12
JFAN6
JFAN6
1 2 3 4 5 6 7 8
BH1X8-1.25PITCH_NATURE-RH
BH1X8-1.25PITCH_NATURE-RH
C1 C10u16Y1206C1C10u16Y1206
VCC12
JFAN7
JFAN7
1 2 3 4 5 6 7 8
C5
BH1X8-1.25PITCH_NATURE-RH
BH1X8-1.25PITCH_NATURE-RH
C10u16Y1206C5C10u16Y1206
4
VCC12
D14
D14
A C
BAS32L_LL34
BAS32L_LL34
VCC12
D6 BAS32L_LL34D6BAS32L_LL34
A C
FANTACH2_B
D10
D10
A C
BAS32L_LL34
BAS32L_LL34
FANTACH3_B
VCC12
D12
D12
A C
BAS32L_LL34
BAS32L_LL34
FANTACH4_B
VCC12
D8
A C
BAS32L_LL34D8BAS32L_LL34
FANTACH5_B
VCC12
D1
A C
BAS32L_LL34D1BAS32L_LL34
FANTACH6_B FANTACH6
VCC12
D4
A C
BAS32L_LL34D4BAS32L_LL34
FANTACH7_B
A C
VCC12
VCC12
VCC12
VCC12
VCC12
VCC12
D13
D13 BAS32L_LL34
BAS32L_LL34
FANTACH1FANTACH1_B
D5 BAS32L_LL34D5BAS32L_LL34
A C
FANTACH2
D9
A C
BAS32L_LL34D9BAS32L_LL34
FANTACH3
D11
D11
A C
BAS32L_LL34
BAS32L_LL34
FANTACH4
D7
A C
BAS32L_LL34D7BAS32L_LL34
FANTACH5
D2
A C
BAS32L_LL34D2BAS32L_LL34
D3
A C
BAS32L_LL34D3BAS32L_LL34
FANTACH7
VCC12 VCC12
C22
C22
C2.2u16Y0805
C2.2u16Y0805
C2
C2
C2.2u16Y0805
C2.2u16Y0805
3
VCC12
VCC12
VCC12
VCC12
78
78
78
78
2
123456
RN16
RN16
8P4R-10KR
8P4R-10KR
123456
RN1
RN1
123456
RN6
RN6
FANTACH4
FANTACH4_B
123456
RN17
RN17
FANTACH6 FANTACH6_B FANTACH7
FANTACH7_B
FANTACH1_B FANTACH1
8P4R-10KR
8P4R-10KR
FANTACH3 FANTACH3_B FANTACH2_B FANTACH2
8P4R-10KR
8P4R-10KR
FANTACH5
8P4R-10KR
8P4R-10KR
FANTACH1_B FANTACH1
FANTACH5 FANTACH5_BFANTACH5_B FANTACH4 FANTACH4_B
RN15 8P4R-4.7KRRN15 8P4R-4.7KR
1 2 3 4 5 6 7 8
FANTACH3 FANTACH3_B FANTACH2_B FANTACH2
RN10
RN10
1 2 3 4 5 6 7 8
FANTACH6 FANTACH6_B FANTACH7 FANTACH7_B
RN7
RN7
8P4R-4.7KR
8P4R-4.7KR
1 2 3 4 5 6 7 8
RN11
RN11
8P4R-4.7KR
8P4R-4.7KR
8P4R-4.7KR
8P4R-4.7KR
RN12 8P4R-4.7KRRN12 8P4R-4.7KR
1 2 3 4 5 6 7 8
8P4R-4.7KR
8P4R-4.7KR
1
FANTACH1_BAK 3 FANTACH1_M 3
123456
78
RN14
RN14
8P4R-4.7KR
8P4R-4.7KR
FANTACH3_M 3 FANTACH3_BAK 3 FANTACH2_BAK 3 FANTACH2_M 3
123456
78
FANTACH5_M 3 FANTACH5_BAK 3 FANTACH4_M 3 FANTACH4_BAK 3
123456
78
RN13
RN13 8P4R-4.7KR
8P4R-4.7KR
FANTACH6_M 3 FANTACH6_BAK 3 FANTACH7_M 3
123456
78
RN8
RN8
FANTACH7_BAK 3
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
MS-95Q6
MS-95Q6
MS-95Q6
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
CPU FAN5 FAN6 0D
CPU FAN5 FAN6 0D
CPU FAN5 FAN6 0D
Date: Sheet of
Date: Sheet of
5
4
3
2
Date: Sheet of
1
49Tuesday, June 24, 2008
49Tuesday, June 24, 2008
49Tuesday, June 24, 2008
Page 5
5
D D
C C
4
3
2
1
VCC3
12
36
U41
U41
FPWM13 FPWM23 FPWM33 FPWM43
ATX_PG_CH
FPWM53 FPWM63 FPWM73
B B
Ref_F10HZ
44
A0/GOE0
45
A1
46
A2
47
A3
48
A4
2
A5
3
A6
4
A7
7
A8
8
A9
9
A10
10
A11
14
A12
15
A13
16
A14
17
A15
43
CLK0/I
18
CLK1/I
19
CLK2/I
42
CLK3/I
VCC#36
GND#13
LC4032V-75TN48C_TQFP48-RH
LC4032V-75TN48C_TQFP48-RH
A A
5
13
6
30
R116
FPWM1_FAN
20
5
VCCO(Bank 1)
GND(Bank0)
B15/GOE1
TDO
TMS
B10 B11 B12 B13 B14
TCK
B0
21
B1
22
B2
23
B3
24
B4
26
B5
27
B6
FPWM7_FAN
28
B7
31
B8
32
B9
33 34 38 39 40 41
1
TDI
35 11 25
VCC#12
VCCO(Bank 0)
GND(Bank 1)
GND#37
29
37
1U_2U_select
TDI_CPLD TDO_CPLD TCK_CPLD TMS_CPLD
FPWM1_FAN 4 FPWM2_FAN 4 FPWM3_FAN 4 FPWM4_FAN 4
R415 0RR415 0R
FPWM5_FAN 4 FPWM6_FAN 4 FPWM7_FAN 4
1U: pull down. 2U: pull high
ATX_PG3
VCC3 VCC3
U61E
U61E
147
11 10
SN74LVC14APWR_TSSOP14
SN74LVC14APWR_TSSOP14
FPWM13
13 12
FPWM23 FPWM33 FPWM43 FPWM53 FPWM63 FPWM73
4
3
R116
150KR
150KR
C10u6.3X5-RH
C10u6.3X5-RH
U61F
U61F
147
ATX_PG_CH
SN74LVC14APWR_TSSOP14
SN74LVC14APWR_TSSOP14
R67 X_0RR67 X_0R R69 X_0RR69 X_0R R68 X_0RR68 X_0R R66 X_0RR66 X_0R R62 X_0RR62 X_0R R63 X_0RR63 X_0R R64 X_0RR64 X_0R
FPWM7_FAN
C371
C371
FPWM1_FAN
U61B
U61B
147
3 4
SN74LVC14APWR_TSSOP14
SN74LVC14APWR_TSSOP14
OD CHANGE
FPWM2_FAN 4 FPWM3_FAN 4 FPWM4_FAN 4 FPWM5_FAN 4 FPWM6_FAN 4
FPWM7_FAN 4
2
147
U61C
U61C
5 6
SN74LVC14APWR_TSSOP14
SN74LVC14APWR_TSSOP14
VCC3
C286
C286
C0.1u16X
C0.1u16X
VCC3
R412 4.7KRR412 4.7KR R413 4.7KRR413 4.7KR
FPWM1_FAN 4
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
Date: Sheet
Date: Sheet
Date: Sheet
R414 4.7KRR414 4.7KR
MS-95Q6
MS-95Q6
MS-95Q6
Power FAN7 0D
Power FAN7 0D
Power FAN7 0D
VCC3VCC3VCC3
9 8
TDO_CPLD TDI_CPLD
TMS_CPLD
TMS_CPLD TCK_CPLD
147
U61D
U61D
Ref_F10HZ
SN74LVC14APWR_TSSOP14
SN74LVC14APWR_TSSOP14
JP5
JP5
1
VCC
2
TDO
3
TDI
4
ispEN
5
TRST
6
TMS
7
GND
8
TCK
X_H1X8M_BLACK-RH-1
X_H1X8M_BLACK-RH-1
of
59Tuesday, June 24, 2008
of
59Tuesday, June 24, 2008
of
59Tuesday, June 24, 2008
1
Page 6
5
NEC REQUEST
RX0+ RX0-
TX0­TX0+
VCCA1
R144 0RR144 0R
OD CHANGE
Near SASC
FB1
FB1
X_80_600mA
X_80_600mA
FB2
FB2
X_80_600mA
X_80_600mA
MATED1 7,8
VCC5
READY1 7
VCC12
NEC REQUEST OD CHANGE
SASC0
SASC0
D D
SAS29PSF-ST_BLACK-RH-1
C C
SAS29PSF-ST_BLACK-RH-1
RX0+ RX0- RX1-
TX0­TX0+
OD CHANGE
GND
TP+
GND
RP+ GND GND
RS+ GND
TS+ GND
V33(pre)
v5(pre)
GND
READY_LED
GND
V12(pre)
S1 S2 S3
TP-
S4 S5
RP-
S6 S7 S8 S9 S10
RS-
S11 S12
TS-
S13 S14 1
V33
2
V33
3 4
Gnd
5
Gnd
6
Gnd
7 8
V5
9
V5
10 11 12 13 14
V12
15
V12
1 2 3 4 5 6 7
SATA7PM_BLACK-P-RH
SATA7PM_BLACK-P-RH
SATA0
SATA0
GND HT+ HT­GND HR­HR+ GND
VCC12A1
Vref1.1V_0
Vref1.1V_0
4
C59
C59 C57
C57
C58
C58 C56
C56
X_C0.1u25Y
X_C0.1u25Y X_C0.1u25Y
X_C0.1u25Y
X_C0.1u25Y
X_C0.1u25Y X_C0.1u25Y
X_C0.1u25Y
SASC1
SASC1
READY_LED
SAS29PSF-ST_BLACK-RH-1
SAS29PSF-ST_BLACK-RH-1
RX1+
TX1­TX1+
OD CHANGE
GND
GND
GND GND
GND
GND
V33(pre)
v5(pre)
GND GND
V12(pre)
TP+
RP­RP+
RS+ RS-
TS+ V33
V33 Gnd
Gnd Gnd
V12 V12
3
NEC REQUEST OD CHANGE
Near SASC
FB4
S1 S2 S3
TP-
S4 S5 S6 S7 S8 S9 S10 S11 S12
TS-
S13 S14 1 2 3 4 5 6 7 8
V5
9
V5
10 11 12 13 14 15
FB4
RX1+ RX1-
FB3
FB3
TX1­TX1+
VCCA2
R145 0RR145 0R
VCC12A2
SATA1
SATA1
1
GND
2
HT+
3
HT-
4
GND
5
HR-
6
HR+
7
GND
SATA7PM_BLACK-P-RH
SATA7PM_BLACK-P-RH
X_80_600mA
X_80_600mA
X_80_600mA
X_80_600mA
MATED2 7,8 MATED3 7,8
VCC12
NEC REQUEST OB CHANGE
C63
C63
Vref1.1V_1
C61
C61
Vref1.1V_1
C62
C62 C60
C60
NEC REQUEST
VCC5
OD CHANGE
READY2 7 READY3 7
X_C0.1u25Y
X_C0.1u25Y X_C0.1u25Y
X_C0.1u25Y
X_C0.1u25Y
X_C0.1u25Y X_C0.1u25Y
X_C0.1u25Y
SASC2
SASC2
GND
TP+
TP-
GND
RP-
RP+ GND GND
RS+
RS-
GND
TS-
TS+ GND
V33
V33
V33(pre)
Gnd
Gnd
Gnd
v5(pre)
V5 V5
GND
READY_LED
GND
V12(pre)
V12
V12
SAS29PSF-ST_BLACK-RH-1
SAS29PSF-ST_BLACK-RH-1
RX2+ RX2-
TX2­TX2+
OD CHANGE
S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
2
Near SASC
FB6
FB6
RX2+ RX2-
FB5
FB5
TX2­TX2+
VCCA3
R146 0RR146 0R
VCC12A3
SATA2
SATA2
1
GND
2
HT+
3
HT-
4
GND
5
HR-
6
HR+
7
GND
SATA7PM_BLACK-P-RH
SATA7PM_BLACK-P-RH
Vref1.1V_2
X_80_600mA
X_80_600mA
Vref1.1V_2
X_80_600mA
X_80_600mA
VCC5
VCC12
C67
C67
X_C0.1u25Y
X_C0.1u25Y
C65
C65
X_C0.1u25Y
X_C0.1u25Y
C66
C66
X_C0.1u25Y
X_C0.1u25Y
C64
C64
X_C0.1u25Y
X_C0.1u25Y
NEC REQUEST OD CHANGE
NEC REQUEST OD CHANGE
1
VCC12A3
VCCA3
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
MS-95Q6
MS-95Q6
MS-95Q6
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
SAS Connector 0D
SAS Connector 0D
SAS Connector 0D
Date: Sheet
Date: Sheet
2
Date: Sheet
1
of
69Tuesday, June 24, 2008
of
69Tuesday, June 24, 2008
of
69Tuesday, June 24, 2008
C46
C46 C1u16Y
C1u16Y
3 1
2
R54 2.7R2512R54 2.7R2512
R52 10R2512R52 10R2512
R95
R95
X_220R1%
X_220R1%
R159
R159
X_180R1%
X_180R1%
NEC REQUEST OD CHANGE
VCC12A2
VCCA2
VCC12A1
VCCA1
4
VCC12
VCC5
C22u16Y1210
C22u16Y1210
R97
R97
X_100R
X_100R
VR1
VR1
X_APL431BAC
X_APL431BAC
C30
C30
C47
C47 C0.1u25Y
C0.1u25Y
R92
R92
X_220R1%
X_220R1%
VR2
VR2
R96
R96
2
X_APL431BAC
X_APL431BAC
X_180R1%
X_180R1%
3 1
VCC5 VCC5VCC5
R158
R158
X_100R
X_100R
3 1
C32
C32
C22u16Y1210
C22u16Y1210
R93
R93
X_220R1%
X_220R1%
Vref1.1V_1 Vref1.1V_2Vref1.1V_0
R94
R94
2
X_180R1%
X_180R1%
3
R160
R160
X_100R
X_100R
VR3
VR3
X_APL431BAC
X_APL431BAC
C1u16Y
C1u16Y
C44
C44 C1u16Y
C1u16Y
R56 2.7R2512R56 2.7R2512
R55 10R2512R55 10R2512
R58 2.7R2512R58 2.7R2512
R57 10R2512R57 10R2512
VCC12
B B
VCC5
C43
C43
C33
C33
C22u16Y1210
C22u16Y1210
VCC12
VCC5
A A
C31
C31
C22u16Y1210
C22u16Y1210
C0.1u25Y
C0.1u25Y
C45
C45
C0.1u25Y
C0.1u25Y
C22u16Y1210
C22u16Y1210
C22u16Y1210
C22u16Y1210
5
C29
C29
C48
C48
C34
C34
Page 7
5
VCC3 VCC5
DSD1
DSD1
13
45
9
39
VCC31VCC
VCC
VCC
SGClock
62 61 58 57
52 51 50 49
56 55 54 53
12
8 7 6
14 15 16 17
64 44
5 21 20
22 24 23 25
43 42 41 40 38 36 35 34
48 26
SGClock SGLoad SGDout SGDin
P_GPI_7_7 P_GPI_7_6 P_GPI_7_5 P_GPI_7_4
P_GPI_8_7 P_GPI_8_6 P_GPI_8_5 P_GPI_8_4
SClock_A SLoad_A SDin_A SDout_A
SClock_B SLoad_B SDin_B SDout_B
Clk32KHZ ResetL MasterSel CntSel_1 CntSel_0
TMS TCK TDI TDO
SlotExistH_7 SlotExistH_6 SlotExistH_5 SlotExistH_4 SlotExistH_3 SlotExistH_2 SlotExistH_1 SlotExistH_0
MateNtfh Mate_Inv
GND10GND
SGLoad
P_GPI_7_5 P_GPI_7_4
SCLOCK_ASCLOCK_A
SLOAD_A
SDATAOUT_A
SDATAIN_A
Clk32KHz Reset# MasterSel Cntsel_1 Cntsel_0
TMS TCK TDI TDO
MateNtfh Mate_Inv
SGDin SGDout
D D
C C
B B
VCC
06/28/07 nec request
04/09/07 nec request
GND
GND
GND60GND65GND79GND
GND
46
32
11
37
88
VCC59VCC63VCC80VCC
VCC
GND
93
90
94
LED_AmbL_7
LED_GmL_7
HDD_RdyL_7
LED_AmbL_6
LED_GmL_6
HDD_RdyL_6
LED_AmbL_5
LED_GmL_5
HDD_RdyL_5
LED_AmbL_4
LED_GmL_4
HDD_RdyL_4
LED_AmbL_3
LED_GmL_3
HDD_RdyL_3
LED_AmbL_2
LED_GmL_2
HDD_RdyL_2
LED_AmbL_1
LED_GmL_1
HDD_RdyL_1
LED_AmbL_0
LED_GmL_0 HDD_RdyL_0
LED_G_Inv LED_A_Inv HDD_R_Inv HDLED_2P
GIbLED_2P
GLED_GrnL GLED_AmbL GLED_G_Inv GLED_A_Inv
[EPM570T100C5N_TQFP100-RH]
[EPM570T100C5N_TQFP100-RH]
HDD LDE Control
VCC3
R39
R39
X_1KR0402
X_1KR0402
HDLED_2P GIBLED_2P LED_A_INV LED_G_INV
R40
A A
R40
1KR0402
1KR0402
VCC3 VCC3
R48
R48
X_1KR0402
X_1KR0402
R41
R41
1KR0402
1KR0402
5
R19
R19
X_1KR0402
X_1KR0402
R20
R20
1KR0402
1KR0402
VCC3
R17
R17
X_1KR0402
X_1KR0402
R18
R18
1KR0402
1KR0402
69 70 68 67
MateH_7
73 74 72 71
MateH_6
77 78 76 75
MateH_5
83 84 82 81
MateH_4
87 89 86 85
MateH_3
95 96 92 91
MateH_2
99 100 98 97
MateH_1
3 4 2 1
MateH_0
28 29 27 47 66
19 18 30 33
JUMPER-1X2A_GREEN-RH-1
JUMPER-1X2A_GREEN-RH-1
Default:2-3
4
JSGPIO1
JSGPIO1
SGClock
1 2
SGLoad
3 4
SGDin SGDout
6
5 7
8
9
BH2X5[10]_BLACK-RH-2
BH2X5[10]_BLACK-RH-2
JSGPIO2
JSGPIO2
SCLOCK_ASCLOCK_A SDATAOUT_A
1 2 3 4
R530RR53
BH2X5[9]_White-RH-2
BH2X5[9]_White-RH-2
0R
OC CHANGE
NEC REQUEST OD CHANGE
FAIL3#
FAIL3# 8
GREEN3#
GREEN3# 8
READY3
MATED3
R142 0RR142 0R R143 0RR143 0R
FAIL2#
FAIL2# 8
GREEN2#
GREEN2# 8
READY2
MATED2
R141 0RR141 0R R140 0RR140 0R
FAIL1#
FAIL1# 8
GREEN1#
GREEN1# 8
READY1
MATED1
R139 0RR139 0R
R138 0RR138 0R
LED_G_INV LED_A_INV HDD_R_INV HDLED_2P GIBLED_2P
GLOBAL_ACT
GLOBAL_FAIL GLED_G_INV GLED_A_INV
JP1 : 1-2 =SAS 2-3=SATA
VCC3
JP1_2-3
JP1_2-3
R6
JP1
JP1
1KR0402R61KR0402
1
HDD_R_INV
2 3
H1X3M_BLACK-RH-2
H1X3M_BLACK-RH-2
4
2.5HDSEL GLOBAL ACT# GLOBAL FAIL#
SDATAIN_ASLOAD_A
675 8 10
READY3 6 MATED3 6,8
READY2 6 MATED2 6,8
READY1 6 MATED1 6,8
NEC REQUEST OD CHANGE
R87
R87
X_4.7KR0402
X_4.7KR0402
R86
R86
X_4.7KR0402
X_4.7KR0402
3
VCC5 VCC5VCC5
R10
R10 10KR
10KR
1 2
R740RR74
0R
VCC3
DSD CLK
C39
C39 C0.1u25Y
C0.1u25Y
R14
R14
1KR0402
1KR0402
R15
R15
X_1KR0402
X_1KR0402
VCC3
R16
R16 10KR
10KR
1 2
VCC3
OD CHANGE
VCC3
R44
R44
X_1KR0402
X_1KR0402
R45
R45
1KR0402
1KR0402
OSC1
OSC1
4
VDD
Tri-state1GND
OSC-32.768KHZ25_S-RH
OSC-32.768KHZ25_S-RH
NEC REQUEST OC CHANGE
GLOBAL_ACT
GLOBAL_FAIL
OD CHANGE
READY2 READY3READY1
MateNtfhMate_Inv
3
OUT
2
VCC3
Q11
Q11
G
VCC3
Q10
Q10
G
3
R27
R27 10KR
10KR
1 2
RN18
RN18
SGDout
12
SGDin
34
SGLoad
56
SGClock
78
X_8P4R-220R0402
X_8P4R-220R0402
Clk32KHz
R47 0RR47 0R
R46
R46 100KRT1%
100KRT1%
R136
R136 220R0402
220R0402
75R0402
75R0402
GLOBAL ACT#
R137
R137
DS
N-2N7002E-E3-T1_SOT23-3-RH
N-2N7002E-E3-T1_SOT23-3-RH
R133
R133
X_0R
X_0R
R134
R134 220R0402
220R0402
75R0402
75R0402
GLOBAL FAIL#
R135
R135
DS
N-2N7002E-E3-T1_SOT23-3-RH
N-2N7002E-E3-T1_SOT23-3-RH
R132
R132
X_0R
X_0R
JP3
JP3
R11
R11 10KR
10KR
C0.1u25Y
C0.1u25Y C14
C14
C54 X_C20p50NC54 X_C20p50N C53 X_C20p50NC53 X_C20p50N C51 X_C20p50NC51 X_C20p50N C49 X_C20p50NC49 X_C20p50N
JP3_2-3
JP3_2-3
X_JUMPER-1X2A_GREEN-RH-1
X_JUMPER-1X2A_GREEN-RH-1
X_H1X3M_BLACK-RH-2
X_H1X3M_BLACK-RH-2
VCC3
R3
X_1KR0402R3X_1KR0402
1 2 3
VCC3
R4
R5
1KR0402R51KR0402
R60
R60 10KR0402
10KR0402
TDO TDI
TMS TCK
JP6_1-2
JP6_1-2
JUMPER-1X2A_GREEN-RH-1
JUMPER-1X2A_GREEN-RH-1
JP6
JP6
1 2 3
H1X3M_BLACK-RH-2
H1X3M_BLACK-RH-2
X_1KR0402R4X_1KR0402
MasterSel
VCC3
P_GPI_7_4 P_GPI_7_5
R21 4.7KR0402R21 4.7KR0402
2
VCC5VCC5
R22
R22 10KR
10KR
MATED2MATED1
1 2
C0.1u25Y
C0.1u25Y C18
C18
VCC3
OD CHANGE
JP2_2_3
JP2_2_3
JUMPER-1X2A_GREEN-RH-1
JUMPER-1X2A_GREEN-RH-1
R59
R59
10KR0402
10KR0402
(Cut pin5)
R61
R61 10KR0402
10KR0402
VCC3 VCC3
R13
R13
4.7KR0402
4.7KR0402
VCC3
JP2
JP2
1
Cntsel_0 Cntsel_1
2 3
H1X3M_BLACK-RH-2
H1X3M_BLACK-RH-2
JPLD1
JPLD1
1 2 3 4 5 6 7 8
H1X8[5]M_BLACK-RH-1
H1X8[5]M_BLACK-RH-1
JP7_1-2
JP7_1-2
JUMPER-1X2A_GREEN-RH-1
JUMPER-1X2A_GREEN-RH-1
R79
R79
X_4.7KR0402
X_4.7KR0402
JP7
JP7
1
R83
R83
2
R50 4.7KR0402R50 4.7KR0402
3
H1X3M_BLACK-RH-2
H1X3M_BLACK-RH-2
X_4.7KR0402
X_4.7KR0402
2
R34
R34 10KR
10KR
C0.1u25Y
C0.1u25Y C23
C23
RN9
RN9
8P4R-2.2KR
8P4R-2.2KR
R89
R89
R7
X_4.7KR0402
X_4.7KR0402
1KR0402R71KR0402
R88
R88
X_4.7KR0402
X_4.7KR0402
NEC REQUEST OD CHANGE
NEC REQUEST OD CHANGE
R84
R84
R51
R51
X_4.7KR0402
X_4.7KR0402
4.7KR0402
4.7KR0402 R85
R85
X_4.7KR0402
X_4.7KR0402
1
1 2
MATED3
SCLOCK_A
12
SLOAD_A
34
SDATAOUT_A
56
SDATAIN_A
78
C20p50N
C20p50N
C16
C16
C20p50N
C20p50N
JUMPER-1X2A_GREEN-RH-1
JUMPER-1X2A_GREEN-RH-1
JP4
JP4
1 2 3
H1X3M_BLACK-RH-2
H1X3M_BLACK-RH-2
C10
C10
C20p50NC9C20p50N
VCC3
R8
1KR0402R81KR0402
NEC REQUEST OD CHANGE
C9
C17
C17
C20p50N
C20p50N
JP4_2_3
JP4_2_3
R90
R90
X_4.7KR0402
X_4.7KR0402
R91
R91
X_4.7KR0402
X_4.7KR0402
VCC3
R33
R33
1KR0402
1KR0402
Reset#
C24
C24
C0.1u16X
C0.1u16X
Global LED and Control
VCC3 VCC3
R25
R23
R23
1KR0402
1KR0402
GLED_G_INV GLED_A_INV
R24
R24
X_1KR0402
X_1KR0402
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
MS-95Q6
MS-95Q6
MS-95Q6
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
DSD 0D
DSD 0D
DSD 0D
Date: Sheet
Date: Sheet
Date: Sheet
R25
1KR0402
1KR0402
R26
R26
X_1KR0402
X_1KR0402
1
of
79Tuesday, June 24, 2008
of
79Tuesday, June 24, 2008
of
79Tuesday, June 24, 2008
Page 8
5
4
3
2
1
VCC3
D D
C C
B B
A A
VCC3
VCC3
VCC3
5
VCC3
VCC3
R29
R29
R28
R28
R37
R37
SAS LED
LED0
LED0
G
G
2 1 4 3
Y
Y
LED04-[YG]-25mA2.8V_3025-RH
LED04-[YG]-25mA2.8V_3025-RH
100R
100R
HDDPWR1
LED1
LED1
G
G
2 1 4 3
Y
Y
LED04-[YG]-25mA2.8V_3025-RH
LED04-[YG]-25mA2.8V_3025-RH
100R
100R
HDDPWR2
LED2
LED2
G
G
2 1 4 3
Y
Y
LED04-[YG]-25mA2.8V_3025-RH
LED04-[YG]-25mA2.8V_3025-RH
100R
100R
HDDPWR3
R42 100RR42 100R
R49 100RR49 100R
LED_MAT0
LED_MAT0
1 2
LED04-G-30mA2.1V_20125-RH
LED04-G-30mA2.1V_20125-RH
R38 100RR38 100R
LED_MAT1
LED_MAT1
1 2
LED04-G-30mA2.1V_20125-RH
LED04-G-30mA2.1V_20125-RH
LED_MAT2
LED_MAT2
1 2
LED04-G-30mA2.1V_20125-RH
LED04-G-30mA2.1V_20125-RH
R43 100RR43 100R
R32 0RR32 0R
100R
100R
R31
R31
R36
R36
R30 0RR30 0R
R35 0RR35 0R
GREEN2#
100R
100R
GREEN1#
FAIL1#
FAIL2#
GREEN3#
FAIL3#
GREEN1# 7
FAIL1# 7
MATED1 6,7
GREEN2# 7
FAIL2# 7
MATED2 6,7
GREEN3# 7
FAIL3# 7
MATED3 6,7
4
3
VCC3
VCC3
VCC3
VCC3
43 21
RN2
RN2
1 2 3 4 5 6 7 8
8P4R-100R
8P4R-100R
RN4
RN4
1 2 3 4 5 6 7 8
8P4R-100R
8P4R-100R
RN5
RN5
1 2 3 4 5 6 7 8
8P4R-100R
8P4R-100R
RN3
RN3
1 2 3 4 5 6 7 8
8P4R-100R
8P4R-100R
FAN LED
FAN_F1_NL FAN_F1_ML
FAN_F2_NL FAN_F2_ML FAN_F3_NL FAN_F3_ML
FAN_F5_NL FAN_F5_ML FAN_F4_ML FAN_F4_NL
FAN_F7_NL FAN_F7_ML FAN_F6_NL FAN_F6_ML
2
NEC REQUEST
FAN_LED1
FAN_LED1
A
FAN_F1_ML
FAN_F1_NL
FAN_F2_ML
FAN_F2_NL
FAN_F3_ML
FAN_F3_NL
FAN_F4_ML
FAN_F4_NL
FAN_F5_ML
FAN_F5_NL
FAN_F6_ML
FAN_F6_NL
FAN_F7_ML
FAN_F7_NL
A
12
34
A
A
LED01-G*2-25mA2.2V-RH
LED01-G*2-25mA2.2V-RH
FAN_LED2
FAN_LED2
A
A
12
34
A
A
LED01-G*2-25mA2.2V-RH
LED01-G*2-25mA2.2V-RH FAN_LED3
FAN_LED3
A
A
12
34
A
A
LED01-G*2-25mA2.2V-RH
LED01-G*2-25mA2.2V-RH
FAN_LED4
FAN_LED4
A
A
12
34
A
A
LED01-G*2-25mA2.2V-RH
LED01-G*2-25mA2.2V-RH FAN_LED5
FAN_LED5
A
A
12
34
A
A
LED01-G*2-25mA2.2V-RH
LED01-G*2-25mA2.2V-RH
FAN_LED6
FAN_LED6
A
A
12
34
A
A
LED01-G*2-25mA2.2V-RH
LED01-G*2-25mA2.2V-RH FAN_LED7
FAN_LED7
A
A
12
34
A
A
LED01-G*2-25mA2.2V-RH
LED01-G*2-25mA2.2V-RH
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
MS-95Q6
MS-95Q6
MS-95Q6
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
LED 0D
LED 0D
LED 0D
Date: Sheet
Date: Sheet
Date: Sheet
FAN_F1_N_M 3
FAN_F1_BAK_N 3
FAN_F2_N_M 3
FAN_F2_BAK_N 3
FAN_F3_N_M 3
FAN_F3_BAK_N 3
FAN_F4_N_M 3
FAN_F4_BAK_N 3
FAN_F5_N_M 3
FAN_F5_BAK_N 3
FAN_F6_N_M 3
FAN_F6_BAK_N 3
FAN_F7_N_M 3
FAN_F7_BAK_N 3
1
OD CHANGE
of
89Tuesday, June 24, 2008
of
89Tuesday, June 24, 2008
of
89Tuesday, June 24, 2008
Page 9
5
4
3
2
1
VCC12 VCC12
D D
C C
VCC5 VCC3
VCC5
C27
C27
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
VCC12
JPWR1
JPWR1
3.3V4GND
3
5V
2
12V
1
12V
PWRCONN8P_WHITE-RH
PWRCONN8P_WHITE-RH
C15
C15
C26
C26
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
GND GND GND
8 7 6 5
C25
C25
C50
C50
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
C55
C55
X_C0.1u25Y
X_C0.1u25Y
C52
C52
C35
C35
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
X_C0.1u25Y0402-RH
C28
C28
X_C0.1u25Y
X_C0.1u25Y
Ci1
Ci1
X_C0.1u25Y
X_C0.1u25Y
VCC5
Ci2
Ci2
X_C0.1u25Y
X_C0.1u25Y
PCB1
PCB1
P30-095Q60C-K10
P30-095Q60C-K10
VCC12 VCC12
C13
VCC5
C37
C37
X_C0.1u25Y
X_C0.1u25Y
C12
C12
X_C0.1u25Y
X_C0.1u25Y
C13 X_C0.1u25Y
X_C0.1u25Y
C38
C38 C0.1u25Y
C0.1u25Y
C36
C36
C2.2u16Y0805
C2.2u16Y0805
C11
C11 C2.2u16Y0805
C2.2u16Y0805
VCC3
C21
C21 X_C0.1u25Y
X_C0.1u25Y
C42
C42 X_C0.1u25Y
X_C0.1u25Y
C20
C20 X_C0.1u25Y
X_C0.1u25Y
C41
C41 C0.1u25Y
C0.1u25Y
C19
C19
C2.2u16Y0805
C2.2u16Y0805
C40
C40
C2.2u16Y0805
C2.2u16Y0805
For FCI SAS Connect
BS3
BS11
BS11 X_MH
X_MH
1
H1
2
H2
3
H3
4
H4
5
H5
6
H6
7
H7
8
H8
B B
A A
9
H9
BS7
BS7 X_MH
X_MH
1
H1
2
H2
3
H3
4
H4
5
H5
6
H6
7
H7
8
H8
9
H9
BJ1
BJ1 X_HOLES_NR157D157
X_HOLES_NR157D157 BJ2
BJ2 X_HOLES_NR157D157
X_HOLES_NR157D157 BJ3
BJ3 X_HOLES_NR157D157
X_HOLES_NR157D157 BJ4
BJ4 X_HOLES_NR157D157
X_HOLES_NR157D157
BS3 X_MH
X_MH
H1 H2 H3 H4 H5 H6 H7 H8 H9
BS4
BS4 X_MH
X_MH
H1 H2 H3 H4 H5 H6 H7 H8 H9
5
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
BS9
BS9 X_MH
X_MH
H1 H2 H3 H4 H5 H6 H7 H8 H9
BS1
BS1 X_MH
X_MH
H1 H2 H3 H4 H5 H6 H7 H8 H9
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
BS5
BS5 X_MH
X_MH
H1 H2 H3 H4 H5 H6 H7 H8 H9
BS2
BS10
BS10
X_MH
1 2 3 4 5 6 7 8 9
X_MH
H1 H2 H3 H4 H5 H6 H7 H8 H9
4
1 2 3 4 5 6 7 8 9
BS2 X_MH
X_MH
1
H1
2
H2
3
H3
4
H4
5
H5
6
H6
7
H7
8
H8
9
H9
BS8
BS8 X_MH
X_MH
1
H1
2
H2
3
H3
4
H4
5
H5
6
H6
7
H7
8
H8
9
H9
HOLES_R339D197_PT
Support FCI SAS change to 9.5mm
TOP SIDE COUPLE BOT SIDE COUPLE
95ohm( 8 / 8 / 20 ) of SAS
JIP4
JIP4
1
L1_8mil_P
X_H1X4_black
X_H1X4_black
X_H1X2_black
X_H1X2_black
3
2 3
L1_8mil_N L4_8mil_N
4
60ohm( 7/ 7 ) 60ohm( 7 / 7)
JIP1
JIP1
1
L1_7mil
2
VCC5
VCC5
2
95ohm( 8 / 8 / 20 ) of SAS
JIP5
JIP5
1
L4_8mil_P
X_H1X4_black
X_H1X4_black
X_H1X2_black
X_H1X2_black
FM5
FM5
1 2
X_FM
X_FM
FM2
FM2
1 2
X_FM
X_FM
MICRO-STAR
MICRO-STAR
MICRO-STAR Title
Title
Title
Size Document Number Rev
Size Document Number Rev
Size Document Number Rev
Date: Sheet
Date: Sheet
Date: Sheet
2 3 4
1 2
1 2
FM4
FM4
X_FM
X_FM
L4_7mil
FM6
FM6
1 2
X_FM
X_FM
FM3
FM3
1 2
X_FM
X_FM
1
FM7
FM7
1 2
X_FM
X_FM
99Tuesday, June 24, 2008
99Tuesday, June 24, 2008
99Tuesday, June 24, 2008
of
of
of
FM1
FM1
1 2
X_FM
X_FM
JIP6
JIP6
FM8
FM8
1 2
X_FM
X_FM
FM9
FM9
1 2
X_FM
X_FM
MS-95Q6
MS-95Q6
MS-95Q6
Power & Layout components 0D
Power & Layout components 0D
Power & Layout components 0D
Loading...