Page 1

5
4
R
e
v
.
2
0
D
3
2
1
D D
MS-6758 ATX
CPU:
Intel Northwood/Prescott - 3.0G & Above
System Chipset:
Intel i875P Canter wood North Bridge
Intel ICH5 South Bridge
C C
On Board Chipset:
BIOS: Intel Firmware Hub
Audio Chip: ALC655/658 AC97 Codec
Super I/O: W83627THF LPC I/O
On Board LAN: RTL8100C/8110S
On Board IEEE1394: VIA VT6306
Clock Generator: ICS952611
Main Memory:
B B
DDR: Dual Channel DDR
Expansion Slots:
AGP 4X/8X Slot * 1
PCI Slot * 5
Intersil PWM:
Controller with driver: HIP6563CR
A A
Regulators
MS-7
01-MS-6758 Rev.20A Over view
02-Block Diagram
03-Power/Clock map
04-GPIO and PCI routing table
05-VRM 10.0
06-Clock Generator and MS-8
07-Intel Socket 478 P4 serial CPU_1
08-Intel Socket 478 P4 serial CPU_2
09-Intel Canter wood FSB/AGP
10-Intel Canter wood Memory
11-Intel Canter wood Power and GND
12-AGP Slot and KB/MS
13-DDR memory Channel A
14-DDR memory Channel B
15-DDR terminator resistor
16-Intel ICH5 Part_1
17-Intel ICH5 Part_2
18-Realtek ALC655/658 AC97 Codec
19-PCI Slot_1 & PCI Slot_2
20-PCI Slot_3 & PCI Slot_4
21-PCI Slot_5 & IDE
22-VIA VT6420 Serial ATA controller
23-VIA VT6306 IEEE1394 controller
24-RealTek RTL8100C/8110S LAN controller
25-W83627THF Super I/O
26-Parallel/Serial Port and USB
27-MS-7 ACPI controller
28-Front ATX Power and Firmware Hub
Title
MS-6758
Size Document Number Rev
Overview 20D
5
4
3
2
Date: Sheet
1
129Friday, February 13, 2004
of
Page 2

5
D D
4
3
2
1
Intel P4 CPU
VRM 10
REQ0
GNT0
REQ1
AGTL+
BUS
AGP 4X/8X BUS
AGP Slot
Intel MCH
Canterwood
DDR DIMM
DDR DIMM
DDR DIMM
INTEL
ICH_5
DDR DIMM
C C
GNT1
REQ2
GNT2
REQ3
GNT3
REQ4
GNT4
REQ5
GNT5
RealTek RTL8110S/8100C LAN Controller
PCI Slot_2
VIA VT6306 IEEE1394 Controller
PCI Slot_3
VIA VT6420 Serial ATA Controller
MS-8
USB Port 1
USB Port 2
USB Port 3
USB Port 4
USB BUS
Link
PCI BUS
PCI BUS
Configuration
PCI
SLOT_1
PCI PCI
SLOT_3 SLOT_5
Hub
USB Port 5
USB Port 6
USB Port 7
ICH5
Soruth Bridge
PCI Slot 2
PCI Slot 3
PCI Slot 1
PCI Slot 4
PCI Slot 5
Serial ATA
RTL8100C/8110S LAN
BUF_RST#
MS-8
Super
I/O
BIOS
ROM
USB Port 8
VIA VT6307
B B
IEEE1394 Port
LPC
IEEE1394
LPC Interface
AC97 Link BUS
AC97 Codec
DEV_RST#
SLOT_RST#
Flash Rom
SATA 1394 LAN
PCI Slot_1
PCI Slot_2
PCI Slot_3
PCI Slot_4
PCI Slot_5
AGP Slot
Keyboard
PS/2 Mouse
A A
5
WINBOND W83627THF
LPC Super I/O
4
Print Prot
MS-7 Reset
Title
MS-6758
Size Document Number Rev
Block Diagram 20D
3
2
Date: Sheet
1
229Friday, February 13, 2004
of
COM Port
Page 3

5
4
3
2
1
D D
C C
ATX 12V POWER Supply
3.3V 5V 5VSB 12V
MSI_MS7
ACPI Controller
Power Delivery Map
VRM 10.0
W83310DS
1.5V
2.6V
1.45/1.225
1.45/1.225
Intel Socket478 P4 serial CPU
Intel Canter wood
NB_VTT
Chipset Core Power
Chipset DRAM Power
AGP Slot
CPU Clock: 533/800MHz
NB clock: 533/800MHz
Clock: 66MHz
Clock: 100MHz
Clock: 66MHz
Clock: 33MHz
Clock: 33MHz
Clock: 33MHz
Clock: 33MHz
Intel Socket478 P4 serial CPU
Intel Canter wood
Intel ICH5 Serial ATA
AGP Slot
PCI Slot
PCI Slot
PCI Slot
PCI Slot
DDR DRAM
Clock: 33MHz
Clock: 33MHz
Clock: 33MHz
Clock: 33MHz
Clock: 33MHz
Clock: 48MHz
PCI Slot
Promise Serial ATA Controller
MSI MS-8
VIA VT6306 IEEE1394
W83627THF Super I/O
W83310DS
1.25V
DDR Terminator
Intel ICH5
B B
Chipset Core Power
3.3VDU
Other Logic
ICS952611 Clock Generator
Promise Serial ATA Controller1.8V
VIA VT6306 IEEE1394
W83627THF Super I/O
PCI Slot
A A
5
4
3
Clock: 66MHz
Clock: 33MHz
Clock: 14MHz
Clock: 66MHz
Intel ICH5
Intel CSA Gigabit LAN
Title
MS-6758
Size Document Number Rev
Power/Clock map 20D
2
Date: Sheet
1
329Friday, February 13, 2004
of
Page 4

5
D D
4
3
2
1
GPIO Table
GPIO on South Bridge
GPIO Name Function Active setup
GPI13 LPC_PME# Low
GPO33 Low is Disable
GPIO27 LPC_SMI# Low
GPIO32 FWH Protect High is Protect
GPIO on W83627THF Super I/O
GPIO Name Function Active setup
C C
B B
GPIO10
GPIO11
GPIO12
GPIO13
GPIO14
GPIO15
GPIO16
GPIO17
GPIO24
GPIO25
GPIO26
Low Low Low
Low Low High
Low High Low
Low High High
High Low Low
ICH_SATA HDD LED
DLED1+
DLED2+
DLED3DLED4DLED1DLED2DLED3+
DLED4+
PCB Version bit 1
PCB Version bit 2
PCB Version bit 3
GPIO24GPIO25GPIO26
LowHigh High
High LowHigh
HighHigh High
Low
Low
High
High
High
High
Low
Low
Low
Low
Low
Description
Standard
Media
No Define
No Define
No Define
No Define
No Define
No Define
PCI IRQ Routing Table
Device AD Select INTA#
PCI Slot_1
PCI Slot_2
PCI Slot_3
PCI Slot_4
PCI Slot_5
AGP Slot
VIA VT6420 SATA
VIA VT6306 1394
RTL8110S LAN AD22 PCI_IRQ#E
AD17 PCI_IRQ#A PCI_IRQ#B PCI_IRQ#C PCI_IRQ#D
AD18 PCI_IRQ#B PCI_IRQ#C PCI_IRQ#D PCI_IRQ#A
AD19 PCI_IRQ#C PCI_IRQ#D PCI_IRQ#A PCI_IRQ#B
AD20 PCI_IRQ#APCI_IRQ#D PCI_IRQ#B PCI_IRQ#C
AD21 PCI_IRQ#B PCI_IRQ#C PCI_IRQ#D PCI_IRQ#A
PCI_IRQ#A PCI_IRQ#BDefault
AD30 PCI_IRQ#G
AD25 PCI_IRQ#F
INTB# INTC# INTD#
PCI_IRQ#H
SMBus Address For DDR Memory
DDR Memory 1: A0
DDR Memory 2: A2
DDR Memory 3: A4
DDR Memory 4: A6
I/O Address For W83627THF Super I/O
W83627THF: 4E/ 48MHZ
GPIO on Firmware Hub
GPI0
GPI1
A A
5
Pri_IDE connector detect
Sec_IDE connector detect
Active setupGPIO Name Function
4
I/O Address For MSI MS-8 ASIC
MSI MS-8 ASIC: 2E/ 33MHz
3
2
Title
MS-6758
Size Document Number Rev
GPIO/Memory/PCI Configuration 20D
Date: Sheet
1
429Friday, February 13, 2004
of
Page 5

5
D D
R69 1.69KR1% R46 X_100R
VCORE VCC
VCORE
C C
R68 1.5KR1%
R67 100R
C74 C0.01U50X
R42 154KR1%
R58 2.43KR1%
R64 5.11KR1%
VRM_EN
VRM_VID4
VRM_VID3
VRM_VID2
VRM_VID1
VRM_VID0
VRM_VID5
R62
20KR1%
R65 X_3KR1%
C79
C5600P50X
+12VA
VRM_GD
VRM_GD27
VCC3
VRM_PWRGD
VRM_VID[5..0]
12
+
EC5
.CD1500U16EL20
CHOCK5 CH-1.1U25A-2
+12VA
C39
C1U16Y0805
VRM_PWRGD6,17,28
VRM_VID[5..0]6
U7
27
Enable
2
VRM_PWRGD
3
VRM_VID4
4
VRM_VID3
5
VRM_VID2
6
VRM_VID1
7
VRM_VID0
8
VRM_VID12.5
13
COMP
VFA
12
FB
VFB
14
VDIFF
15
VSENSE
16
RGND
11
REF
28
FS
10
TCOMP
ISL6556BCB_SOIC28
R37 5.62KR1%
R26 1KR1%
R233 1KR C271 X_C0.1U50Y
Closed to South Bridge
12
+
EC6
.CD1500U16EL20
VCC
PWM1
ISEN1
PWM2
ISEN2
PWM3
ISEN3
PWM4
ISN4
OVP
OFS
GND
Q14
N-MMBT3904_SOT23
VRM_PWRGD
4
26
22
R50 4.7KR1%
23
21
R53 4.7KR1%
20
18
R57 4.7KR1%
19
25
R48 4.7KR1%
24
1
R54 X_470KR1%
9
VREFB
17
12
+
EC4
.CD1500U16EL20
PWM1
ISEN1
PWM2
ISEN2
PWM3
ISEN3
PWM4
ISEN4
VRM_EN
12
+
EC53
.CD1500U16EL20
R39
1KR1%
C65
C1U16Y0805
VCC
VCC
C20
X_C1U16Y0805
C13
X_C0.1U50Y
3
C23 C0.1U50Y
ISEN3
ISEN4
C24 C0.1U50Y
+12VA
VIN12
C21
C0.1U50Y
ISEN1
C32 C0.1U50Y
ISEN2
C33 C0.1U50Y
+12VA
PWM3
PWM4
R14 4.7R0805
R15 4.7R0805
R20 4.7R0805
PWM1
PWM2
R18 4.7R0805
R19 4.7R0805
R16 4.7R0805
U1BOOT
U1VCC
C42
C0.1U50Y
U1GND
C30
C0.1U50Y
11
10
14
U6
1
PWM1
2
PWM2
11
BOOT1
10
BOOT2
14
VCC
5
PVCC
3
GND
6
PGND
HIP6602B_SO14
U4
1
PWM1
2
PWM2
BOOT1
BOOT2
VCC
5
PVCC
3
GND
6
PGND
HIP6602B_SO14
UGATE1
PHASE1
LGATE1
UGATE2
PHASE2
LGATE2
UGATE1
PHASE1
LGATE1
UGATE2
PHASE2
LGATE2
2
UGATE1
R5 2.2R0805
12
ISEN1
13
LGATE1 LG1
R444 2.2R0805
4
R1 2.2R0805
UGATE2
9
ISEN2
8
R445 2.2R0805
7
R3 2.2R0805
UGATE3
12
ISEN3
13
R446 2.2R0805
4
UGATE4
R13 2.2R0805
9
ISEN4
8
R447 2.2R0805
7
G
Q1
N-IPD09N03LA_TO252
G
Q9
N-IPD06N03LA_TO252
G
Q2
N-IPD09N03LA_TO252
LG2LGATE2
G
Q4
N-IPD06N03LA_TO252
G
Q3
N-IPD09N03LA_TO252
LG3LGATE3
Q5
N-IPD06N03LA_TO252
N-IPD09N03LA_TO252
Q6
N-IPD06N03LA_TO252
G
G
Q7
LG4LGATE4
G
VIN12
DS
C22
C1U16Y0805
DS
LG1
Q2042
X_N-IPB06N03LA_TO263
VIN12
DS
C1
C1U16Y0805
DS
LG2
Q2043
X_N-IPB06N03LA_TO263
DS
DS
DS
DS
VIN12
C11
C1U16Y0805
LG3
Q2044
X_N-IPB06N03LA_TO263
VIN12
C444
C1U16Y0805
LG4
Q2045
X_N-IPB06N03LA_TO263
G
G
G
G
1
DS
C18 C1000P50X
DS
C2 C1000P50X
DS
C16 C1000P50X
DS
C19 C1000P50X
R11
2.2R
R2
2.2R
R10
2.2R
R12
2.2R
UGATE3
ISEN3
LGATE3
VREFB
R47 2.15KR1%
Q16
DS
N-2N7002_SOT23
MSGPO2
G
VREFB
R41 10KR
Title
MS-6758
Size Document Number Rev
VRM 10.0 20D
Date: Sheet
1
529Friday, February 13, 2004
of
R49 8.45KR1% R51 4.22KR1%
Q17
B B
VRM_VID4
VRM_VID3
VRM_VID2
VRM_VID1
VRM_VID0
VRM_VID5
A A
5
RN11
7
8
5
6
3
4
1
2
8P4R-1KR
R43 1KR
R44 1KR
C59
X_C1U16Y0805
VCC3
+12VA
C40
C0.1U50Y
JPWR2
3
4
PWR-2X2M
4
1
GND
12V
2
GND
12V
ISEN1
CHOCK4 CH-0.9U25A
ISEN2
CHOCK2 CH-0.9U25A
ISEN3
CHOCK1 CH-0.9U25A
ISEN4
CHOCK3 CH-0.9U25A
VCORE
VCORE
3
DS
N-2N7002_SOT23
MSGPO0 MSGPO1
G
R45 10KR
U1BOOT
PWM3
U1VCC
U1GND
VREFB
Q18
DS
N-2N7002_SOT23
MSGPO0 6 MSGPO1 6 MSGPO2 6
G
R56 10KR
U5
2
BOOT
3
PWM
6
VCC
7
PVCC
4
GND
UGATE
PHASE
LGATE
1
8
5
X_HIP6601B_SOIC8
2
Page 6

5
U10
C200 C0.1U50Y
V33CLK
C190 C0.1U50Y
D D
C C
V33CLK
C191 C0.1U50Y
V33CLK
C193 C0.1U50Y
V33CLK
C192 C0.1U50Y
V33CLK
C223 C0.1U50Y
V33CLK
V33CLK
V33CLK
C218 C56P50N
C213 C56P50N
VRM_PWRGD5,17,28
14.318MHZ32P_D
VRM_PWRGD
3
VDD_REF
6
GND1
10
VDD_PCI1
11
GND2
17
VDD_PCI2
18
GND3
25
VDD_48M
28
VDD_3V66
29
GND5
35
VDD_SRC
38
GND6
41
VDD_CPU
44
GND7
48
VDDA
47
GND8
4
XTAL_IN
Y1
5
XTAL_OUT
34
VTT_PWRGD/PD#
ICS952611_SSOP48
CPU_CLK0
CPU_CLK0#
CPU_CLK1
CPU_CLK1#
SRC
SRC#
3V_66M_0
3V_66M_1
3V_66M_2
3V_66M_3
**FS3/48M_0GND4
**SEL24/48#
*FS_A/REF0
*FS_B/REF1
**FS2/PCI_F0
**FS4/PCI_F1
PCI_F2
PCI0
PCI1
PCI2
PCI3
PCI4
PCI5
PCI6
PCI7
SMBDATA
SMBCLK
RESET#
IREF
4
R142 33R1%
40
R143 33R1%
39
R140 33R1%
43
R141 33R1%
42
R144 33R1%
37
R145 33R1%
36
RN54 8P4R-33R
1
31
3
30
5
27
7
26
FS3
R183 33R
2324
R170 33R
22
REF0
R171 10KR1%
1
REF1
R187 10KR1%
2
7
FS2
7
5
3
FS4
8
1
RN94 8P4R-22R
9
P12
12
7
5
RN61 8P4R-33R
13
3
14
1
15
16
7
5
RN95 8P4R-33R
19
3
20
1
21
R360 4.7KR
33
32
R147 X_0R
45
R146 X_0R
R148 475R1%
46
3
CPU_CLK
CPU_CLK#
NB_CLK
NB_CLK#
SATA_CLK100
SATA_CLK100#
NB_CLK66
2
SB_CLK66
4
AGP_CLK66
6
EI_CLK66
8
SB_USB48M
SIO_48M
CPU_BSEL0
CPU_BSEL1
SB_PCLK33
8
SIO_PCLK33
6
MSI_PCLK33
4
FWH_PCLK33
2
PCI5_CLK
SATA_PCLK33
8
6
1394_PCLK33
4
PCI_PCLK1
2
PCI_PCLK2
PCI_PCLK3
8
6
PCI_PCLK4
4
PCI_PCLK5
2
TURBO
SMBDATA
SMBCLK
ICH_RST#
FP_RST#
CPU_CLK 7
CPU_CLK# 7
NB_CLK 9
NB_CLK# 9
SATA_CLK100 17
SATA_CLK100# 17
NB_CLK66 9
SB_CLK66 17
AGP_CLK66 12
EI_CLK66 24
SB_USB48M 17
SIO_48M 25
CPU_BSEL0 7
CPU_BSEL1 7
SB_PCLK33 16
SIO_PCLK33 25
FWH_PCLK33 28
PCI5_CLK 21
SATA_PCLK33 22
1394_PCLK33 23
PCI_PCLK1 19
PCI_PCLK2 19
PCI_PCLK3 20
PCI_PCLK4 20
PCI_PCLK5 21
TURBO 25
VCC3
SMBDATA 13,14,17,21,25,27
SMBCLK 13,14,17,21,25,27
ICH_RST# 17,28
FP_RST# 27,28
P12
FS2
FS3
FS4
CPU_CLK
CPU_CLK#
NB_CLK
NB_CLK#
SATA_CLK100
SATA_CLK100#
REF0
REF1
CPU_BSEL0
CPU_BSEL1
R182 2.2KR
R173 1KR
R167 1KR
R164 1KR
R137 49.9R1%
R134 49.9R1%
R135 49.9R1%
R136 49.9R1%
R138 49.9R1%
R139 49.9R1%
R172 33R
R188 33R
R177 1KR1%
R184 1KR1%
SB_14M
AC97_14M
SB_14M 17
AC97_14M 18
VCC3
VCC3
2
GP0_8.45K GP1_4.22K GP2_2.15K
00 0
00 1
01 0
101
100
10 1
11 0
111
CP17
V33CLK
X_COPPER
C196
C0.1U50Y
VCC3
C447
C10U6.3Y1206
1
Delt_V
0
0.4
0.2
0.6
0.1
0.5
0.3
0.7
U17
B B
LPC_LAD317,25
LPC_LAD217,25
LPC_LAD117,25,28
LPC_LAD017,25,28
LPC_FRAME#17,25,28
CHIP_RST#24,25,27,28
NB_BSEL19
NB_BSEL09
A A
MSI_PCLK33
LPC_SAD3
LPC_LAD3
LPC_SAD2
LPC_LAD2
LPC_LAD1
LPC_LAD0
LPC_FRAME#
CHIP_RST#
MS8_RST#
EN_DUBIOS
MSGPO0
MSGPO05
MSGPO1
MSGPO15
MSGPO2
MSGPO25
CPU_BSEL1
CPU_BSEL0
NB_BSEL1
NB_BSEL0
VRM_VID5
VRM_VID4
VRM_VID3
VRM_VID2
VRM_VID1
VRM_VID0
5
MS8-C
1
PCICLK
2
LAD3_OUT/GPIOC1
3
LAD3
4
LAD2_OUT/GPIOC3
5
LAD2
6
LAD1
7
LAD0
8
LFRAME#
9
PCIRST#
11
RSTOUT#
13
BEEP/GPIOB4/ENDLBIOS
14
PSON_OUT#/GPIOB2
15
PSON_IN#/GPIOB1
16
THERMTRIP#/GPIOB0
17
BSEL_IN1/GPIOA0
18
BSEL_IN0/GPIOA1
19
BSEL_OUT1/GPIOA2
20
BSEL_OUT0/GPIOA3
21
VID_OUT5
22
VID_OUT4
23
VID_OUT3
24
VID_OUT2
25
VID_OUT1
26
VID_OUT0
CPU_VID[5..0]
VRM_VID[5..0]5
MS-8
CPU_VID[5..0] 7
VRM_VID[5..0]
3VSB
ADDRSEL/GPIOC2
FRAME#/GPIOD7
STOP#/GPIOD6
SGNT0#/GPIOE1
SREQ0#/GPIOE0
SGNT1#/GPIOD5
SREQ1#/GPIOD4
SGNT2#/GPIOD3
SREQ2#/GPIOD2
PGNT#/GPIOD1
PREQ#/GPIOD0
VID_IN0
VID_IN1
VID_IN2
VID_IN3
VID_IN4
VID_IN5
3VSB
SLOTOCC#
VBAT
PWRBTN/GPIOB3
DGND0
DGND
4
48
AD_SEL
47
PCI_FRAME#
46
PCI_STOP#
45
PCI5_GNT#
44
PCI5_REQ#
43
1394_GNT#
42
1394_REQ#
41
PCI_GNT#0
40
PCI_REQ#0
39
PCI_GNT#5
38
PCI_REQ#5
37
CPU_VID0
35
CPU_VID1
34
CPU_VID2
33
CPU_VID3
32
CPU_VID4
31
CPU_VID5
30
29
SLOTSOC#
28
VBAT
27
12
10
36
3VDU
3VDU
PCI_FRAME# 16,19,20,21,22,23
PCI_STOP# 16,19,20,21,22,23
PCI5_GNT# 21
PCI5_REQ# 21
1394_GNT# 23
1394_REQ# 23
PCI_GNT#0 19
PCI_REQ#0 19
PCI_GNT#5 16
PCI_REQ#5 16
3VDU
SLOTSOC# 7
CS1 C0.1U16X
C288 C0.1U50Y
C311 C0.1U50Y
Closed to MS8 Power Pin
0730 Modified
EN_DUBIOS
EN_DUBIOS: High is Enable
EN_DUBIOS: Low is Disable
LPC_SAD3
LPC_LAD3
LPC_SAD2
LPC_LAD2
AD_SEL
VBAT
MS8 Address High is 4E/4F
MS8 Address Low is 2E/2F
NB_BSEL1
NB_BSEL0
SLOTSOC#
MS8_RST#
3
R294 X_1KR
R292 1KR
R291 X_0R
R289 0R
R290 X_0R
R288 0R
3VDU
Safe BIOS Function
R281 X_1KR
R277 1KR
R149 1KR
R267 1KR
R262 10MR
R293 X_0R
R295 0R
ICH_RST#
FP_RST#
FWH_AD3 28
FWH_AD2 28
3VDU
VCC1.5
VCC1.5
VBAT
2
CPU_VID4
CPU_VID3
CPU_VID1
CPU_VID0
CPU_VID2
CPU_VID5
7
8
5
6
3
4
1
2
RN62 8P4R-4.7KR
R260 4.7KR
R261 4.7KR
RN64 8P4R-2.7KR
PCI_REQ#5
PCI_REQ#0
PCI5_REQ#
VCC3
Title
MS-6758
Size Document Number Rev
Clock Generator and MS-8 20D
Date: Sheet
1394_REQ#
1394_GNT#
PCI5_GNT#
PCI_GNT#0
PCI_GNT#5
1
2
3
4
5
6
7
8
RN66 X_8P4R-2.7KR
1
2
3
4
5
6
7
8
1
629Friday, February 13, 2004
VCC
VCC3
of
Page 7

5
D D
CPU1A
_ZIF-SOCKET478
CPU_DBI#0
CPU_DBI#1
CPU_DBI#2
CPU_DBI#3
CPU_FERR#17
CPU_STPCLK#17
CPU_INIT#17,28
CPU_DBSY#9
CPU_DRDY#9
CPU_TRDY#9
CPU_ADS#9
CPU_LOCK#9
C C
CPU_THERMDA25
CPU_THERMTRIP#17
CPU_PROCHOT#9
CPU_BNR#9
CPU_HIT#9
CPU_HITM#9
CPU_BPRI#9
CPU_DEFER#9
LPC_AGND25
SLOTSOC#6
CPU_IGNNE#17
CPU_SMI#17
CPU_A20M#17
CPU_SLP#17
VID_PWRGD27
CPU_BSEL06
B B
CPU_BSEL16
CPU_PWRGD17
CPU_RST#9
CPU_FERR#
CPU_STPCLK#
CPU_INIT#
CPU_DBSY#
CPU_DRDY#
CPU_TRDY#
CPU_ADS#
CPU_LOCK#
CPU_BNR#
CPU_HIT#
CPU_HITM#
CPU_BPRI#
CPU_DEFER#
CPU_TDI
CPU_TDO
CPU_TMS
CPU_TRST#
CPU_TCK
CPU_THERMDA
LPC_AGND
CPU_THERMTRIP#
SLOTSOC#
CPU_PROCHOT#
CPU_IGNNE#
CPU_SMI#
CPU_A20M#
CPU_SLP#
VID_PWRGD
CPU_BSEL0
CPU_BSEL1
CPU_PWRGD
CPU_RST#
CPU_HD#63
CPU_HD#62
CPU_HD#61
CPU_HD#60
CPU_HD#59
CPU_HD#58
CPU_HD#57
CPU_HD#56
CPU_HD#55
CPU_HD#54
AF26
AB26
AE21
AF24
AF25
AB23
AB25
AA24
AA22
AA25
W25
W26
G25
P26
V21
AC3
AA3
AB2
A22
AD2
AD6
AD5
E21
V6
B6
Y4
W5
H5
H2
J6
G1
G4
G2
F3
E3
D2
E2
C1
D5
F7
E6
D4
B3
C4
A2
C3
B2
B5
C6
A7
Y21
Y24
Y23
Y26
V24
DBI0#
DBI1#
DBI2#
DBI3#
IERR#
MCERR#
FERR#
STPCLK#
BINIT#
INIT#
RSP#
DBSY#
DRDY#
TRDY#
ADS#
LOCK#
BNR#
HIT#
HITM#
BPRI#
DEFER#
TDI
TDO
TMS
TRST#
TCK
THERMDA
THERMDC
THERMTRIP#
GND/SKTOCC#
PROCHOT#
IGNNE#
SMI#
A20M#
SLP#
RESERVED0
RESERVED1
VCCVID_PWRGD
RESERVED4
RESERVED5
RESERVED6
BSEL0
BSEL1
PWRGOOD
RESET#
D63#
D62#
D61#
D60#
D59#
D58#
D57#
D56#
D55#
D54#
V22
CPU_AD#31
AB1Y1W2V3U4T5W1R6V2T4U3P6U1T2R3P4P3R2T1N5N4N2M1N1M4M3L2M6L3K1L6K4K2
A35#
A34#
A33#
A32#
D53#
D52#
D51#
D50#
D49#
D48#
D47#
U21
V25
U23
U24
U26
T23
CPU_AD#30
CPU_AD#29
A31#
A30#
A29#
D46#
D45#
D44#
T22
T25
T26
CPU_AD#28
CPU_AD#26
CPU_AD#25
CPU_AD#27
A28#
A27#
A26#
D43#
D42#
D41#
R24
R25
P24
R21
4
CPU_AD#24
CPU_AD#22
CPU_AD#23
A25#
A24#
A23#
A22#
D40#
D39#
D38#
D37#
N25
N26
M26
CPU_AD#20
CPU_AD#21
CPU_AD#18
CPU_AD#19
A21#
A20#
A19#
D36#
D35#
D34#
N23
M24
P21
N22
CPU_AD#16
CPU_AD#17
CPU_AD#15
A18#
A17#
A16#
A15#
D33#
D32#
D31#
D30#
M23
H25
K23
CPU_AD#12
CPU_AD#14
CPU_AD#13
CPU_AD#11
A14#
A13#
A12#
D29#
D28#
D27#
J24
L22
M21
H24
CPU_AD#8
CPU_AD#9
CPU_AD#10
A9#
A8#
A11#
A10#
D26#
D25#
D24#
D23#
G26
L21
D26
CPU_AD#5
CPU_AD#6
CPU_AD#7
A7#
A6#
A5#
D22#
D21#
D20#
F26
E25
F24
CPU_AD#4
CPU_AD#3
A4#
A3#
D19#
D18#
D17#
F23
G23
E24
AE25A5A4
DBR#
D16#
D15#
H22
D25
VCC_SENSE
D14#
D13#
J21
D23
C26
AD26
AC26
ITP_CLK1
ITP_CLK0
VSS_SENSE
D12#
D11#
D10#
D9#
H21
G22
B25
C24
CPU_VID4
CPU_VID5
AE1
AD3
VID5#
VID4#
D8#
D7#
D6#
C23
B24
3
CPU_VID3
CPU_VID2
CPU_VID1
AE2
AE3
AE4
VID3#
VID2#
VID1#
D5#
D4#
D3#
D22
C21
A25
CPU_VID0
AE5
VID0#
GTLREF3
GTLREF2
GTLREF1
GTLREF0
BPM5#
BPM4#
BPM3#
BPM2#
BPM1#
BPM0#
REQ4#
REQ3#
REQ2#
REQ1#
REQ0#
TESTHI12
TESTHI11
TESTHI10
TESTHI9
TESTHI8
ITPCLK1
ITPCLK0
TESTHI5
TESTHI4
TESTHI3
TESTHI2
TESTHI1
TESTHI0
BCLK1#
BCLK0#
COMP1
COMP0
ADSTB1#
ADSTB0#
DSTBP3#
DSTBP2#
DSTBP1#
DSTBP0#
DSTBN3#
DSTBN2#
DSTBN1#
DSTBN0#
LINT1/NMI
LINT0/INTR
D2#
D1#
D0#
A23
B22
B21
RS2#
RS1#
RS0#
AP1#
AP0#
BR0#
DP3#
DP2#
DP1#
DP0#
AA21
AA6
F20
F6
AB4
AA5
Y6
AC4
AB5
AC6
H3
J3
J4
K5
J1
AD25
A6
Y3
W4
U6
AB22
AA20
AC23
AC24
AC20
AC21
AA2
AD24
AF23
AF22
F4
G5
F1
V5
AC1
H6
P1
L24
L25
K26
K25
J26
R5
L5
W23
P23
J23
F21
W22
R22
K22
E22
E5
D1
CPU_GTLREF
CPU_BMP#5
CPU_BMP#4
CPU_BMP#3
CPU_BMP#2
CPU_BMP#1
CPU_BMP#0
CPU_REQ#4
CPU_REQ#3
CPU_REQ#2
CPU_REQ#1
CPU_REQ#0
TESTHI12
TESTHI11
TESTHI10
TESTHI9
TESTHI8
TESTHI2
TESTHI1
TESTHI0
CPU_CLK#
CPU_CLK
CPU_RS#2
CPU_RS#1
CPU_RS#0
CPU_BR#0
CPU_COMP1
CPU_COMP0
CPU_ADSTB#1
CPU_ADSTB#0
CPU_DSTB3
CPU_DSTB2
CPU_DSTB1
CPU_DSTB0
CPU_DSTB#3
CPU_DSTB#2
CPU_DSTB#1
CPU_DSTB#0
CPU_LINT1
CPU_LINT0
CPU_GTLREF 9
R82 62R
R29 62R
R84 62R
CPU_CLK# 6
CPU_CLK 6
CPU_RS#2 9
CPU_RS#1 9
CPU_RS#0 9
CPU_BR#0 9
R74 53.6R1%
R60 53.6R1%
CPU_ADSTB#1 9
CPU_ADSTB#0 9
CPU_DSTB3 9
CPU_DSTB2 9
CPU_DSTB1 9
CPU_DSTB0 9
CPU_DSTB#3 9
CPU_DSTB#2 9
CPU_DSTB#1 9
CPU_DSTB#0 9
CPU_LINT1 17
CPU_LINT0 17
VCORE
2
Trace width is 10 mils
Space is 7 mils
Closed to CPU
CPU_TDI
CPU_TDO
CPU_TMS
CPU_TRST#
CPU_TCK
VID_PWRGD
CPU_PWRGD
CPU_RST#
CPU_VID[5..0]
CPU_AD#[31..3]
CPU_DBI#[3..0]
CPU_HD#[63..0]
CPU_REQ#[4..0]
CPU_PROCHOT#
CPU_PWRGD
CPU_BR#0
CPU_RST#
TESTHI0
CPU_BMP#0
CPU_BMP#2
CPU_BMP#1
CPU_BMP#5
CPU_BMP#3
CPU_BMP#4
TESTHI10
TESTHI1
TESTHI9
TESTHI8
CPU_GTLREF
C116
X_C220P50N
RN28
1
2
3
4
5
6
7
8
8P4R-62R
RN30
1
2
3
4
5
6
7
8
8P4R-62R
RN27
1
2
3
4
5
6
7
8
8P4R-62R
VCORE
C117
C0.1U50Y
R36 X_150R1%
R32 X_75R1%
R31 X_47R
R35 680R
R30 X_47R
C63 X_C10P50Y
C283 X_C10P50Y
C112 X_C10P50Y
CPU_VID[5..0] 6
CPU_AD#[31..3] 9
CPU_DBI#[3..0] 9
CPU_HD#[63..0] 9
CPU_REQ#[4..0] 9
R34 62R
R240 330R
R33 200R
R89 62R
PCB
VCORE
VCORE
VCORE
R94
200R1%
R95
169R1%
1
VCORE
VCORE
PCB
CPU_HD#11
CPU_HD#10
CPU_HD#13
CPU_HD#15
CPU_HD#14
CPU_HD#12
CPU_HD#16
CPU_HD#17
CPU_HD#19
CPU_HD#18
CPU_HD#21
CPU_HD#23
CPU_HD#22
CPU_HD#20
CPU_HD#26
CPU_HD#31
CPU_HD#25
CPU_HD#28
CPU_HD#24
CPU_HD#30
CPU_HD#27
CPU_HD#29
CPU_HD#32
CPU_HD#33
CPU_HD#35
CPU_HD#34
CPU_HD#37
CPU_HD#39
CPU_HD#38
CPU_HD#36
CPU_HD#42
CPU_HD#47
CPU_HD#41
CPU_HD#44
CPU_HD#40
CPU_HD#46
CPU_HD#43
CPU_HD#45
CPU_HD#48
CPU_HD#53
CPU_HD#51
CPU_HD#50
CPU_HD#49
CPU_HD#52
CPU_HD#7
CPU_HD#8
CPU_HD#9
CPU_HD#4
CPU_HD#5
CPU_HD#6
CPU_HD#1
CPU_HD#2
CPU_HD#3
CPU_HD#0
_
A A
Title
MS-6758
Size Document Number Rev
Intel Pentium 4 CPU_1 20D
5
4
3
2
Date: Sheet
1
729Friday, February 13, 2004
of
Page 8

5
4
3
2
1
VCORE VCC_VID
CPU1B
A10
A12
A14
A16
A18
A20A8AA10
AA12
AA14
AA16
AA18
AA8
AB11
AB13
AB15
AB17
AB19
AB7
AB9
AC10
AC12
AC14
AC16
AC18
AC8
AD11
AD13
AD15
AD17
AD19
AD7
AD9
AE10
AE12
AE14
AE16
AE18
AE20
AE6
AE8
AF11
AF13
AF15
AF17
AF19
AF2
AF21
AF5
AF7
AF9
B11
B13
B15
B17
B19B7B9
C10
C12
C14
C16
C18
C20C8D11
D13
D15
D17
D19D7D9
E10
E12
E14
E16
E18
E20E8F11
F13
F15
F17
F19
AF4
VCC
VSS
VCC
VSS
VCC
VSS
G21G6G24
VCC
VCC
VCC
VSS
VSS
VSS
G3H1H23
F9
VCC
VCC_VID
VSS
VSS
VSS
VSS
H26H4J2
D D
C C
VCORE
0228 Modified
R81
X_680R
BOOT_SEL28
BOOT_SEL
_ZIF-SOCKET478
D10
VSS
A11
VSS
A13
VSS
A15
VSS
A17
VSS
A19
VSS
A21
VSS
A24
VSS
A26
VSS
A3
VSS
A9
VSS
AA1
VSS
AA11
VSS
AA13
VSS
AA15
VSS
AA17
VSS
AA19
VSS
AA23
VSS
AA26
VSS
AA4
VSS
AA7
VSS
AA9
VSS
AB10
VSS
AB12
VSS
AB14
VSS
AB16
VSS
AB18
VSS
AB20
VSS
AB21
VSS
AB24
VSS
AB3
VSS
AB6
VSS
AB8
VSS
AC11
VSS
AC13
VSS
AC15
VSS
AC17
VSS
AC19
VSS
AC2
VSS
AC22
VSS
AC25
VSS
AC5
VSS
AC7
VSS
AC9
VSS
AD1
VSS
VCC
VSS
AD10
VCC
VSS
AD12
VCC
VSS
AD14
VCC
VSS
AD16
VCC
VSS
AD18
AD21
VCC
VSS
VCC
VSS
AD23
AD4
VCC
VSS
AD8
VCC
VSS
AE11
VCC
VSS
VCC
VSS
AE13
VCC
VSS
AE15
VCC
VSS
AE17
VCC
VSS
AE19
VCC
VSS
AE22
VCC
VSS
AE24
AE26
VCC
VSS
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
AE7
AE9
AF1
AF10
AF12
AF14
AF16
AF18
AF20
AF6
AF8
B10
B12
B14
B16
B18
B23
B20
B26B4B8
C11
C13
C15
C17C2C19
C22
C25C5C7C9D12
D14
D16
D18
D20
D21D3D24D6D8E1E11
E13
E15
E17
E19
E23
E7E9F10
E4
E26
VSS
F12
F14
F16
F18F2F22
F25F5F8
AF3
VCC_VID
VSS
VSS
J22
AE23
VCCA
VSS
VSS
J25J5K21
VCCA
VCC_IOPLL
AD20
VSSA
VCC_IOPLL
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
AD22
Y5
Y25
Y22
Y2
W6
W3
W24
W21
V4
V26
V23
V1
U5
U25
U22
U2
T6
T3
T24
T21
R4
R26
R23
R1
P5
P25
P22
P2
N6
N3
N24
N21
M5
M25
M22
M2
L4
L26
L23
L1
K6
K3
K24
VSSA
B B
R83 X_0R
VCORE
12
+
EC54
.CD3300U6.3EL25
12
+
EC55
.CD3300U6.3EL25
12
+
EC56
.CD3300U6.3EL25
VCC_IOPLL
C118
C1U16Y
VCCA
C114
C1U16Y
C109
C22U10Y1206
VSSA
A A
5
4
Pin AE26 will be detected on Prescott .
12
+
EC57
.CD3300U6.3EL25
L6 4.7U100m_1206
L5 4.7U100m_1206
VCORE
VCORE
12
+
EC58
.CD3300U6.3EL25
VCORE
12
+
EC2029
.CD3300U6.3EL25
C85
C22U10Y1206
C86
C22U10Y1206
3
VCORE
C45
C10U6.3Y1206
C70
C22U10Y1206
C100
C22U10Y1206
C36
C22U10Y1206
12
+
C81
C100U2SP
HT1
_E91-0000036
123
123
4
4
C38
C22U10Y1206
12
+
C75
X_C100U6.3SP
VCORE
VCORE
VCORE
2
C44
C10U6.3Y1206
C102
C22U10Y1206
C101
C10U6.3Y1206
C71
C22U10Y1206
C99
C10U6.3Y1206
C35
C22U10Y1206
C37
C22U10Y1206
C47
C10U6.3Y1206
C46
C10U6.3Y1206
Title
MS-6758
Size Document Number Rev
Intel Pentium 4 CPU_2 20D
Date: Sheet
1
829Friday, February 13, 2004
of
Page 9

5
4
3
2
1
D D
C C
CPU_ADSTB#07
CPU_ADSTB#17
CPU_DSTB07
CPU_DSTB17
CPU_DSTB27
CPU_DSTB37
CPU_DSTB#07
CPU_DSTB#17
CPU_DSTB#27
CPU_DSTB#37
B B
CPU_RS#07
CPU_RS#17
CPU_RS#27
CPU_ADS#7
CPU_TRDY#7
CPU_DRDY#7
CPU_DEFER#7
CPU_HITM#7
CPU_HIT#7
CPU_LOCK#7
CPU_BR#07
CPU_BNR#7
CPU_BPRI#7
CPU_DBSY#7
A A
CPU_AD#3
CPU_AD#4
CPU_AD#5
CPU_AD#6
CPU_AD#7
CPU_AD#8
CPU_AD#9
CPU_AD#10
CPU_AD#11
CPU_AD#12
CPU_AD#13
CPU_AD#14
CPU_AD#15
CPU_AD#16
CPU_AD#17
CPU_AD#18
CPU_AD#19
CPU_AD#20
CPU_AD#21
CPU_AD#22
CPU_AD#23
CPU_AD#24
CPU_AD#25
CPU_AD#26
CPU_AD#27
CPU_AD#28
CPU_AD#29
CPU_AD#30
CPU_AD#31
CPU_REQ#0
CPU_REQ#1
CPU_REQ#2
CPU_REQ#3
CPU_REQ#4
CPU_ADSTB#0
CPU_ADSTB#1
NB_CLK
NB_CLK6
NB_CLK#
NB_CLK#6
HDRCOMP
HDSWING
CPU_DSTB0
CPU_DSTB1
CPU_DSTB2
CPU_DSTB3
CPU_DSTB#0
CPU_DSTB#1
CPU_DSTB#2
CPU_DSTB#3
CPU_DBI#0
CPU_DBI#1
CPU_DBI#2
CPU_DBI#3
CPU_RS#0
CPU_RS#1
CPU_RS#2
CPU_ADS#
CPU_TRDY#
CPU_DRDY#
CPU_DEFER#
CPU_HITM#
CPU_HIT#
CPU_LOCK#
CPU_BR#0
CPU_BNR#
CPU_BPRI#
CPU_DBSY#
HT2
1
1
2
2
_
NB_FAN
5
E13
G12
E10
H12
F11
E9
F9
J9
G8
H10
J11
J7
F7
H8
A17
C17
B17
B11
C9
C13
A14
A13
A15
D8
C8
B15
D14
C12
C7
E11
F13
G13
E12
G14
G9
D16
E8
E7
A12
A6
E26
F21
D22
G19
A26
E22
B23
F19
B31
F25
C20
J17
D12
G10
G11
A9
J13
A11
D10
A8
B7
C11
H14
B13
C14
B9
VCC1.5
CB14
X_C2.2U6.3Y
U9A
HA3
HA4
HA5
HA6
HA7
HA8
HA9
HA10
HA11
HA12
HA13
HA14
HA15
HA16
HA17
HA18
HA19
HA20
HA21#
HA22
HA23
HA24
HA25
HA26
HA27
HA28
HA29
HA30
HA31
HREQ0
HREQ1
HREQ2
HREQ3
HREQ4
HADSTB0
HADSTB1
HCLKP
HCLKN
HDRCOMP
HDSWING
HDSTBP0
HDSTBP1
HDSTBP2
HDSTBP3
HDSTBN0
HDSTBN1
HDSTBN2
HDSTBN3
DBI_0
DBI_1
DBI_2
DBI_3
RS0
RS1
RS2
ADS
HTRDY
DRDY
DEFER
HITM
HIT
HLOCK
BREQ0
BNR
BPRI
DBSY
(INTEL-RG82875-A2)
CB12
C1U16Y
HD10
HD11
HD12
HD13
HD14
HD15
HD16
HD17
HD18
HD19
HD20
HD21
HD22
HD23
HD24
HD25
HD26
HD27
HD28
HD29
HD30
HD31
HD32
HD33
HD34
HD35
HD36
HD37
HD38
FSB
HD39
HD40
HD41
HD42
HD43
HD44
HD45
HD46
HD47
HD48
HD49
HD50
HD51
HD52
HD53
HD54
HD55
HD56
HD57
HD58
HD59
HD60
HD61
HD62
HD63
GTLREF
HDVREF
PROCHOT#
BSEL0
BSEL1
CPURST#
PWROK#
CB13
X_C2.2U6.3Y
HD0
HD1
HD2
HD3
HD4
HD5
HD6
HD7
HD8
HD9
C29
D28
A28
E27
E28
C27
C28
B29
A29
B27
D26
C26
B25
A27
A25
C25
J21
H23
H20
H24
G26
H22
G23
G25
G21
E24
E25
G24
F23
G22
E23
E21
A23
C23
C24
A21
D24
C22
C21
A22
D20
B21
A19
B19
C18
C19
D18
A18
J19
G20
E20
E18
E19
G18
E17
F17
G16
E16
G15
J15
E14
H16
G17
E15
F15
A7
C10
C15
C16
H18
AE9
CB7
C1U16Y
CPU_HD#0
CPU_HD#1
CPU_HD#2
CPU_HD#3
CPU_HD#4
CPU_HD#5
CPU_HD#6
CPU_HD#7
CPU_HD#8
CPU_HD#9
CPU_HD#10
CPU_HD#11
CPU_HD#12
CPU_HD#13
CPU_HD#14
CPU_HD#15
CPU_HD#16
CPU_HD#17
CPU_HD#18
CPU_HD#19
CPU_HD#20
CPU_HD#21
CPU_HD#22
CPU_HD#23
CPU_HD#24
CPU_HD#25
CPU_HD#26
CPU_HD#27
CPU_HD#28
CPU_HD#29
CPU_HD#30
CPU_HD#31
CPU_HD#32
CPU_HD#33
CPU_HD#34
CPU_HD#35
CPU_HD#36
CPU_HD#37
CPU_HD#38
CPU_HD#39
CPU_HD#40
CPU_HD#41
CPU_HD#42
CPU_HD#43
CPU_HD#44
CPU_HD#45
CPU_HD#46
CPU_HD#47
CPU_HD#48
CPU_HD#49
CPU_HD#50
CPU_HD#51
CPU_HD#52
CPU_HD#53
CPU_HD#54
CPU_HD#55
CPU_HD#56
CPU_HD#57
CPU_HD#58
CPU_HD#59
CPU_HD#60
CPU_HD#61
CPU_HD#62
CPU_HD#63
CPU_GTLREF
NB_GTLREF
CPU_PROCHOT#
NB_BSEL0
NB_BSEL1
CPU_RST#
CHIP_PWROK
CPU_GTLREF 7
CPU_PROCHOT# 7
NB_BSEL0 6
NB_BSEL1 6
CPU_RST# 7
CHIP_PWROK 16,17,27
Trace width is 10 mils
Space is 7 mils
Closed to NB
NB_CSASWING
NB_CSAVREF
4
AGP_VSWING12
NB_HLSWING17
NB_CSASTRF24
NB_CSASTRS24
NB_HLSTRF17
NB_HLSTRS17
NB_HLVREF17
AGP_CBE012
AGP_CBE112
AGP_CBE212
AGP_CBE312
AGP_ST012
AGP_ST112
AGP_ST212
AGP_VREF12
NB_CLK666
PCI_RST#16,27
ICH_SYNC16
C2258
C0.1U50Y
C2260
C0.1U50Y
VTT_NB
AGP_CBE0
AGP_CBE1
AGP_CBE2
AGP_CBE3
AGP_ST0
AGP_ST1
AGP_ST2
AGP_VREF
AGP_VSWING
AGP_RCOMP
NB_CLK66
NB_HL0
NB_HL1
NB_HL2
NB_HL3
NB_HL4
NB_HL5
NB_HL6
NB_HL7
NB_HL8
NB_HL9
NB_HL10
NB_HLSTRF
NB_HLSTRS
NB_HLVREF
NB_HLSWING
NB_HLRCOMP
NB_CSA0
NB_CSA1
NB_CSA2
NB_CSA3
NB_CSA4
NB_CSA5
NB_CSA6
NB_CSA7
NB_CSA8
NB_CSA9
NB_CSA10
NB_CSASTRF
NB_CSASTRS
NB_CSAVREF
NB_CSASWING
NB_CSARCOMP
PCI_RST#
ICH_SYNC
R127 1KR
C175
C0.1U50Y
VCC1.5
R2338
226R1%
R2340
147R1%
R2341
113R1%
U9D
AG4
GCBE0
AC5
GCBE1
AA3
GCBE2
V3
GCBE3
U7
GST0
U8
GST1
W8
GST2
AD2
GVREF
AC1
GVSWING
AC3
GRCOMP
G7
GCLKIN
AL4
HI0
AK5
HI1
AM4
HI2
AJ6
HI3
AN6
HI4
AL8
HI5
AM8
HI6
AN7
HI7
AL7
HI8
AN4
HI9
AM6
HI10
AK6
HISTRF
AL5
HISTRS
AF1
HI_VREF
AD3
HI_SWING
AD1
HI_RCOMP
AG9
CI0
AK9
CI1
AL9
CI2
AH9
CI3
AF7
CI4
AF6
CI5
AG6
CI6
AH5
CI7
AH7
CI8
AE7
CI9
AH8
CI10
AK7
CISTRF
AJ8
CISTRS
AG1
CI_VREF
AE3
CI_SWING
AF2
CI_RCOMP
AF14
EXTTS
AE8
RSTIN
AC7
ICH_SYNC
AM31
RESERVED_1
AL32
RESERVED_2
AN9
RESERVED_3
AC9
RESERVED_4
AG8
RESERVED_5
A5
RESERVED_6
(INTEL-RG82875-A2)
AGP
HUB
CSA
NB_CSARCOMP
NB_CSAVREF
Closed to NB
NB_CSA[10..0]
3
GADSTBF0
GADSTBS0
GADSTBF1
GADSTBS1
GAD0
GAD1
GAD2
GAD3
GAD4
GAD5
GAD6
GAD7
GAD8
GAD9
GAD10
GAD11
GAD12
GAD13
GAD14
GAD15
GAD16
GAD17
GAD18
GAD19
GAD20
GAD21
GAD22
GAD23
GAD24
GAD25
GAD26
GAD27
GAD28
GAD29
GAD30
GAD31
GSBSTBF
GSBSTBS
GSBA0#
GSBA1#
GSBA2#
GSBA3#
GSBA4#
GSBA5#
GSBA6#
GSBA7#
GFRAME
GDEVSEL
GIRDY
VGA
GTRDY
GSTOP
GPAR/ADD_DETECT
GREQ
GGNT
GRBF
GWBF
DBI_HI
DBI_LO
R2339 52.3R1%
C2259 C0.1U50Y
AGP_ADSTBF0
AF3
AGP_ADSTBS0
AG3
AGP_ADSTBF1
V1
AGP_ADSTBS1
V2
AGP_AD0
AK1
AGP_AD1
AK2
AGP_AD2
AJ1
AGP_AD3
AK3
AGP_AD4
AJ3
AGP_AD5
AJ4
AGP_AD6
AH2
AGP_AD7
AH1
AGP_AD8
AF5
AGP_AD9
AE4
AGP_AD10
AE5
AGP_AD11
AD5
AGP_AD12
AD6
AGP_AD13
AD8
AGP_AD14
AC4
AGP_AD15
AC8
AGP_AD16
AA4
AGP_AD17
Y2
AGP_AD18
Y1
AGP_AD19
W1
AGP_AD20
Y3
AGP_AD21
W4
AGP_AD22
W3
AGP_AD23
U1
AGP_AD24
U3
AGP_AD25
U4
AGP_AD26
R1
AGP_AD27
T2
AGP_AD28
T3
AGP_AD29
R3
AGP_AD30
P1
AGP_AD31
R4
AGP_SBSTBF
Y6
AGP_SBSTBS
W5
AGP_SBA#0
V5
AGP_SBA#1
V6
AGP_SBA#2
Y7
AGP_SBA#3
W7
AGP_SBA#4
AA8
AGP_SBA#5
Y5
AGP_SBA#6
AA5
AGP_SBA#7
AA7
AGP_FRAME
AB7
AGP_DEVSEL
AB2
AGP_IRDY
AB6
AGP_TRDY
AB1
AGP_STOP
AB5
AGP_PAR
AB3
AGP_REQ
T5
AGP_GNT
T6
AGP_RBF
V7
AGP_WBF
U5
AGP_DBIH
N1
AGP_DBIL
P2
NB_CSA[10..0] 24
NB_HLRCOMP
AGP_RCOMP
HDRCOMP
AGP_VREF
NB_HLVREF
VCC1.5
AGP_ADSTBF0 12
AGP_ADSTBS0 12
AGP_ADSTBF1 12
AGP_ADSTBS1 12
AGP_SBSTBF 12
AGP_SBSTBS 12
AGP_FRAME 12
AGP_DEVSEL 12
AGP_IRDY 12
AGP_TRDY 12
AGP_STOP 12
AGP_PAR 12
AGP_REQ 12
AGP_GNT 12
AGP_RBF 12
AGP_WBF 12
AGP_DBIH 12
AGP_DBIL 12
R163 52.3R1%
R176 43.2R1%
R119 20R1%
C235 C0.1U50Y
C281 C0.1U50Y
Closed to NB
Trace width is 10 mils
Space is 7 mils
Closed to NB
NB_GTLREF
CB5
X_C0.1U50Y
Trace width is 10 mils
Space is 7 mils
Closed to NB
HDSWING
CB6
X_C0.1U50Y
Trace width is 10 mils
Space is 7 mils
Closed to NB
NB_HLSWING
CB18
X_C0.1U50Y
NB_HLVREF
VCC1.5
2
CB19
C0.1U50Y
CPU_AD#[31..3]
CPU_REQ#[4..0]
CPU_DBI#[3..0]
CPU_HD#[63..0]
NB_HL[10..0]
AGP_AD[31..0]
AGP_SBA#[7..0]
Title
Size Document Number Rev
Date: Sheet
VTT_NB
R123
200R1%
C170
C0.1U50Y
VTT_NB
R122
301R1%
C172
C0.1U50Y
C230
C0.1U50Y
C237
X_C0.1U50Y
CPU_AD#[31..3] 7
CPU_REQ#[4..0] 7
CPU_DBI#[3..0] 7
CPU_HD#[63..0] 7
NB_HL[10..0] 17
AGP_AD[31..0] 12
AGP_SBA#[7..0] 12
VCC1.5
R124
102R1%
R180
226R1%
R199
147R1%
R189
113R1%
MS-6758
Intel I875P FSB and AGP 20D
1
929Friday, February 13, 2004
of
Page 10

5
D D
DVREF
U9B
AC29
SMAA_A0
AH32
SMAA_A1
AG31
SMAA_A2
AJ29
SMAA_A3
AK30
SMAA_A4
AN28
SMAA_A5
AK28
SMAA_A6
AM27
SMAA_A7
AL27
SMAA_A8
AL26
SMAA_A9
AD30
SMAA_A10
AN26
SMAA_A11
AL24
SMAA_A12
W31
SBA_A0
AB30
SBA_A1
U31
SWE_A
T33
SCAS_A
V31
SRAS_A
T31
SCS_A0
P32
SCS_A1
T30
SCS_A2
R33
SCS_A3
AM24
SCKE_A0
AL22
SCKE_A1
AL23
SCKE_A2
AN23
SCKE_A3
AE31
SCMDCLK_A0
AE32
SCMDCLK_A0#
AN20
SCMDCLK_A1
AM21
SCMDCLK_A1#
J32
SCMDCLK_A2
J33
SCMDCLK_A2#
AG32
SCMDCLK_A3
AG33
SCMDCLK_A3#
AM19
SCMDCLK_A4
AL19
SCMDCLK_A4#
K30
SCMDCLK_A5
K31
SCMDCLK_A5#
AG13
SMXRCOMP
AN13
SMXRCOMPVOH
AH13
SMXRCOMPVOL
C32
SMVREF_A
AN15
SDQS_A0
AJ19
SDQS_A1
AL25
SDQS_A2
AL30
SDQS_A3
AA30
SDQS_A4
R31
SDQS_A5
J31
SDQS_A6
F30
SDQS_A7
AF33
SDQS_A8
(INTEL-RG82875-A2)
DDRB_MAB[12..0]
DDRB_CLK[5..0]
DDRB_CLK#[5..0]
AL15
SDQ_A0
AM15
SDQ_A1
AJ17
SDQ_A2
AM16
SDQ_A3
AN14
SDQ_A4
AK16
SDQ_A5
AL16
SDQ_A6
AN16
SDQ_A7
AL17
SDQ_A8
AN17
SDQ_A9
AL21
SDQ_A10
AM22
SDQ_A11
AL18
SDQ_A12
AN19
SDQ_A13
AK20
SDQ_A14
AN21
SDQ_A15
AK24
SDQ_A16
AN25
SDQ_A17
AK26
SDQ_A18
AM28
SDQ_A19
AN24
SDQ_A20
AM25
SDQ_A21
AN27
SDQ_A22
AL28
SDQ_A23
AN29
SDQ_A24
AL29
SDQ_A25
AJ31
SDQ_A26
AH30
SDQ_A27
AJ27
SDQ_A28
DDR Channel A
AJ28
SDQ_A29
AK31
SDQ_A30
AH31
SDQ_A31
AA28
SDQ_A32
AA33
SDQ_A33
Y33
SDQ_A34
W32
SDQ_A35
AA31
SDQ_A36
AA32
SDQ_A37
Y31
SDQ_A38
W33
SDQ_A39
V33
SDQ_A40
U32
SDQ_A41
P31
SDQ_A42
N31
SDQ_A43
V30
SDQ_A44
U33
SDQ_A45
M31
SDQ_A46
M33
SDQ_A47
L31
SDQ_A48
L32
SDQ_A49
H30
SDQ_A50
G33
SDQ_A51
L33
SDQ_A52
K33
SDQ_A53
H33
SDQ_A54
H31
SDQ_A55
F33
SDQ_A56
F31
SDQ_A57
D31
SDQ_A58
E31
SDQ_A59
G32
SDQ_A60
G31
SDQ_A61
E33
SDQ_A62
E32
SDQ_A63
AG30
SECC_A0
AF31
SECC_A1
AE33
SECC_A2
AC33
SECC_A3
AJ33
SECC_A4
AH33
SECC_A5
AC31
SECC_A6
AB33
SECC_A7
DDRB_MAB[12..0] 14,15
DDRB_CLK[5..0] 14
DDRB_CLK#[5..0] 14
DDRA_MD0
DDRA_MD1
DDRA_MD2
DDRA_MD3
DDRA_MD4
DDRA_MD5
DDRA_MD6
DDRA_MD7
DDRA_MD8
DDRA_MD9
DDRA_MD10
DDRA_MD11
DDRA_MD12
DDRA_MD13
DDRA_MD14
DDRA_MD15
DDRA_MD16
DDRA_MD17
DDRA_MD18
DDRA_MD19
DDRA_MD20
DDRA_MD21
DDRA_MD22
DDRA_MD23
DDRA_MD24
DDRA_MD25
DDRA_MD26
DDRA_MD27
DDRA_MD28
DDRA_MD29
DDRA_MD30
DDRA_MD31
DDRA_MD32
DDRA_MD33
DDRA_MD34
DDRA_MD35
DDRA_MD36
DDRA_MD37
DDRA_MD38
DDRA_MD39
DDRA_MD40
DDRA_MD41
DDRA_MD42
DDRA_MD43
DDRA_MD44
DDRA_MD45
DDRA_MD46
DDRA_MD47
DDRA_MD48
DDRA_MD49
DDRA_MD50
DDRA_MD51
DDRA_MD52
DDRA_MD53
DDRA_MD54
DDRA_MD55
DDRA_MD56
DDRA_MD57
DDRA_MD58
DDRA_MD59
DDRA_MD60
DDRA_MD61
DDRA_MD62
DDRA_MD63
DDRA_ECC0
DDRA_ECC1
DDRA_ECC2
DDRA_ECC3
DDRA_ECC4
DDRA_ECC5
DDRA_ECC6
DDRA_ECC7
DDRA_MAA0
DDRA_MAA1
DDRA_MAA2
DDRA_MAA3
DDRA_MAA4
DDRA_MAA5
DDRA_MAA6
DDRA_MAA7
DDRA_MAA8
DDRA_MAA9
DDRA_MAA10
DDRA_MAA11
DDRA_MAA12
DDRA_BANKA013,15
DDRA_BANKA113,15
DDRA_WE13,15
DDRA_CAS13,15
C C
B B
A A
DDRA_RAS13,15
DDRA_CS013,15
DDRA_CS113,15
DDRA_CS213,15
DDRA_CS313,15
DDRA_CKE013,15
DDRA_CKE113,15
DDRA_CKE213,15
DDRA_CKE313,15
DDRA_BANKA0
DDRA_BANKA1
DDRA_WE
DDRA_CAS
DDRA_RAS
DDRA_CS0
DDRA_CS1
DDRA_CS2
DDRA_CS3
DDRA_CKE0
DDRA_CKE1
DDRA_CKE2
DDRA_CKE3
DDRA_CLK0
DDRA_CLK#0
DDRA_CLK1
DDRA_CLK#1
DDRA_CLK2
DDRA_CLK#2
DDRA_CLK3
DDRA_CLK#3
DDRA_CLK4
DDRA_CLK#4
DDRA_CLK5
DDRA_CLK#5
DDRA_RCOMP
DDRA_RCOMPH
DDRA_RCOMPL
C125 X_C0.1U50Y
C119 C1U16Y0805
DDRA_DQS0
DDRA_DQS1
DDRA_DQS2
DDRA_DQS3
DDRA_DQS4
DDRA_DQS5
DDRA_DQS6
DDRA_DQS7
DDRA_DQS8
4
VDIMM
Trace width is 10 mils
Space is 7 mils
R213
42.2R1%
Closed to NB
C249
C4.7U10Y0805
DDRA_RCOMP
R214
42.2R1%
Trace width is 10 mils
Space is 7 mils
VDIMM
Closed to NB
C241
C1U16Y0805
R175
10KR1%
DDRA_RCOMPH
R162
30.1KR1%
VDIMM
C231
X_C0.1U50Y
C225
C0.1U50Y
Trace width is 10 mils
Space is 7 mils
R201
30.1KR1%
Closed to NB
VDIMM
R77
X_150R1%
R76
X_150R1%
DDRA_MAA[12..0]
DDRA_CLK[5..0]
DDRA_CLK#[5..0]
DDRA_DQS[8..0]
DDRA_MD[63..0]
DDRA_ECC[7..0]
DDRA_RCOMPL
R202
10KR1%
C246
C0.1U50Y
Trace width is 10 mils
Space is 7 mils
Closed to NB
DVREF
DDRA_MAA[12..0] 13,15
DDRA_CLK[5..0] 13
DDRA_CLK#[5..0] 13
DDRA_DQS[8..0] 13,15
DDRA_MD[63..0] 13,15
DDRA_ECC[7..0] 13,15
C250
C4.7U10Y0805
3
U9C
DDRB_MAB0
DDRB_MAB1
DDRB_MAB2
DDRB_MAB3
DDRB_MAB4
DDRB_MAB5
DDRB_MAB6
DDRB_MAB7
DDRB_MAB8
DDRB_MAB9
DDRB_MAB10
DDRB_MAB11
DDRB_MAB12
DDRB_BANKB014,15
DDRB_BANKB114,15
DDRB_WE14,15
DDRB_CAS14,15
DDRB_RAS14,15
DDRB_CS014,15
DDRB_CS114,15
DDRB_CS214,15
DDRB_CS314,15
DDRB_CKE014,15
DDRB_CKE114,15
DDRB_CKE214,15
DDRB_CKE314,15
DDRB_BANKB0
DDRB_BANKB1
DDRB_WE
DDRB_CAS
DDRB_RAS
DDRB_CS0
DDRB_CS1
DDRB_CS2
DDRB_CS3
DDRB_CKE0
DDRB_CKE1
DDRB_CKE2
DDRB_CKE3
DDRB_CLK0
DDRB_CLK#0
DDRB_CLK1
DDRB_CLK#1
DDRB_CLK2
DDRB_CLK#2
DDRB_CLK3
DDRB_CLK#3
DDRB_CLK4
DDRB_CLK#4
DDRB_CLK5
DDRB_CLK#5
DDRB_RCOMP
DDRB_RCOMPH
DDRB_RCOMPL
DDRB_VREF
DDRB_DQS0
DDRB_DQS1
DDRB_DQS2
DDRB_DQS3
DDRB_DQS4
DDRB_DQS5
DDRB_DQS6
DDRB_DQS7
DDRB_DQS8
AB26
SMAA_B0
AH29
SMAA_B1
AG29
SMAA_B2
AH27
SMAA_B3
AF27
SMAA_B4
AF24
SMAA_B5
AG25
SMAA_B6
AG23
SMAA_B7
AE23
SMAA_B8
AJ22
SMAA_B9
AA25
SMAA_B10
AG22
SMAA_B11
AL20
SMAA_B12
V26
SBA_B0
AB31
SBA_B1
U29
SWE_B
R25
SCAS_B
U28
SRAS_B
P26
SCS_B0
T29
SCS_B1
T27
SCS_B2
R27
SCS_B3
AE21
SCKE_B0
AF21
SCKE_B1
AG20
SCKE_B2
AH19
SCKE_B3
AE29
SCMDCLK_B0
AD29
SCMDCLK_B0#
AG18
SCMDCLK_B1
AF18
SCMDCLK_B1#
M30
SCMDCLK_B2
M29
SCMDCLK_B2#
AD27
SCMDCLK_B3
AC27
SCMDCLK_B3#
AG17
SCMDCLK_B4
AH17
SCMDCLK_B4#
M26
SCMDCLK_B5
M27
SCMDCLK_B5#
AD31
SMYRCOMP
N32
SMYRCOMPVOH
N33
SMYRCOMPVOL
AN12
SMVREF_B
AL14
SDQS_B0
AF16
SDQS_B1
AJ21
SDQS_B2
AG26
SDQS_B3
W25
SDQS_B4
R28
SDQS_B5
L29
SDQS_B6
K26
SDQS_B7
AC28
SDQS_B8
(INTEL-RG82875-A2)
DDRB_DQS[8..0]
DDRB_MD[63..0]
DDRB_ECC[7..0]
DDR Channel B
2
AG14
SDQ_B0
AL13
SDQ_B1
AK14
SDQ_B2
AJ15
SDQ_B3
AJ13
SDQ_B4
AM13
SDQ_B5
AJ14
SDQ_B6
AH15
SDQ_B7
AG15
SDQ_B8
AG16
SDQ_B9
AK18
SDQ_B10
AE19
SDQ_B11
AJ16
SDQ_B12
AE17
SDQ_B13
AG19
SDQ_B14
AJ18
SDQ_B15
AG21
SDQ_B16
AH21
SDQ_B17
AH23
SDQ_B18
AG24
SDQ_B19
AJ20
SDQ_B20
AF22
SDQ_B21
AJ23
SDQ_B22
AJ24
SDQ_B23
AJ25
SDQ_B24
AJ26
SDQ_B25
AG27
SDQ_B26
AD26
SDQ_B27
AF25
SDQ_B28
AE25
SDQ_B29
AE26
SDQ_B30
AG28
SDQ_B31
Y26
SDQ_B32
AA29
SDQ_B33
W27
SDQ_B34
V27
SDQ_B35
Y27
SDQ_B36
Y29
SDQ_B37
W28
SDQ_B38
W29
SDQ_B39
U27
SDQ_B40
T26
SDQ_B41
P27
SDQ_B42
N25
SDQ_B43
V29
SDQ_B44
U25
SDQ_B45
R29
SDQ_B46
P30
SDQ_B47
N29
SDQ_B48
N27
SDQ_B49
K29
SDQ_B50
L25
SDQ_B51
P29
SDQ_B52
N28
SDQ_B53
L28
SDQ_B54
L27
SDQ_B55
K27
SDQ_B56
H29
SDQ_B57
G29
SDQ_B58
H27
SDQ_B59
J29
SDQ_B60
J28
SDQ_B61
J27
SDQ_B62
G28
SDQ_B63
AE28
SECC_B0
AF29
SECC_B1
AB27
SECC_B2
AA27
SECC_B3
AE27
SECC_B4
AC25
SECC_B5
AD32
SECC_B6
AB29
SECC_B7
DDRB_DQS[8..0] 14,15
DDRB_MD[63..0] 14,15
DDRB_ECC[7..0] 14,15
DDRB_MD0
DDRB_MD1
DDRB_MD2
DDRB_MD3
DDRB_MD4
DDRB_MD5
DDRB_MD6
DDRB_MD7
DDRB_MD8
DDRB_MD9
DDRB_MD10
DDRB_MD11
DDRB_MD12
DDRB_MD13
DDRB_MD14
DDRB_MD15
DDRB_MD16
DDRB_MD17
DDRB_MD18
DDRB_MD19
DDRB_MD20
DDRB_MD21
DDRB_MD22
DDRB_MD23
DDRB_MD24
DDRB_MD25
DDRB_MD26
DDRB_MD27
DDRB_MD28
DDRB_MD29
DDRB_MD30
DDRB_MD31
DDRB_MD32
DDRB_MD33
DDRB_MD34
DDRB_MD35
DDRB_MD36
DDRB_MD37
DDRB_MD38
DDRB_MD39
DDRB_MD40
DDRB_MD41
DDRB_MD42
DDRB_MD43
DDRB_MD44
DDRB_MD45
DDRB_MD46
DDRB_MD47
DDRB_MD48
DDRB_MD49
DDRB_MD50
DDRB_MD51
DDRB_MD52
DDRB_MD53
DDRB_MD54
DDRB_MD55
DDRB_MD56
DDRB_MD57
DDRB_MD58
DDRB_MD59
DDRB_MD60
DDRB_MD61
DDRB_MD62
DDRB_MD63
DDRB_ECC0
DDRB_ECC1
DDRB_ECC2
DDRB_ECC3
DDRB_ECC4
DDRB_ECC5
DDRB_ECC6
DDRB_ECC7
C1U16Y
C134
V25_CAP3
R121
42.2R1%
DDRB_RCOMP
R117
42.2R1%
Trace width is 10 mils
Space is 7 mils
V25_CAP1
Closed to NB
R109
10KR1%
DDRB_RCOMPH
R107
30.1KR1%
V25_CAP1
R104
30.1KR1%
DDRB_RCOMPL
R108
10KR1%
VDIMM
Trace width is 10 mils
Space is 7 mils
R215
150R1%
Closed to NB
DDRB_VREF
R211
C1U16Y
150R1%
1
Trace width is 10 mils
Space is 7 mils
Closed to NB
C142
X_C0.1U50Y
C152
C0.1U50Y
Trace width is 10 mils
Space is 7 mils
Closed to NB
C145
C0.1U50Y
CB1
C220
X_C0.1U50Y
Title
MS-6758
Size Document Number Rev
Intel I875P DDR interface 20D
5
4
3
2
Date: Sheet
1
10 29Friday, February 13, 2004
of
Page 11

5
4
3
2
1
U9E
D D
C C
B B
A A
VTT_NB
VTT_NB
VTT_CAP4
VTT_CAP1
VTT_CAP2
VTT_CAP3
(INTEL-RG82875-A2)
L22
VTT
L21
VTT
L20
VTT
L19
VTT
L18
VTT
L17
VTT
L16
VTT
L15
VTT
L14
VTT
L13
VTT
K12
VTT
H6
VTT
H5
VTT
G6
VTT
G5
VTT
G4
VTT
F5
VTT
F4
VTT
E6
VTT
E5
VTT
E4
VTT
E3
VTT
D5
VTT
D4
VTT
D3
VTT
C6
VTT
C5
VTT
C4
VTT
C3
VTT
B5
VTT
B4
VTT
B3
VTT
A24
VTT
A20
VTT
A16
VTT
A10
VTT
D6
VTT
A4
VTT
AE13
TESTLOW
AM18
TESTLOW
AH20
TESTLOW
AH24
TESTLOW
AB32
TESTLOW
T32
TESTLOW
L30
TESTLOW
E29
TESTLOW
AK13
TESTLOW
AH16
TESTLOW
AH26
TESTLOW
AF28
TESTLOW
W30
TESTLOW
U30
TESTLOW
R26
TESTLOW
N26
TESTLOW
K9
TEST
K8
TEST
K10
TEST
K11
TEST
AC26
TEST
AK32
TEST
AH25
TEST
AK23
TEST
AK21
TEST
AE30
TEST
AK29
TEST
AM30
TEST
AK22
TEST
AF19
TEST
AN31
NC_1
AN3
NC_2
AM32
NC_3
AM2
NC_4
AL33
NC_5
AL1
NC_6
C33
NC_7
C1
NC_8
B32
NC_9
B2
NC_10
A31
NC_11
A3
NC_12
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
POWER
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VCC3_3
VCCA_FSB
VCCA_FSB
VCCA_DDR
VCCA_DDR
VCCA_DDR
VCCA_DDR
J25
J24
J23
J22
J20
J18
J16
J14
J12
J10
J8
H32
H28
H26
H25
H21
H19
H17
H15
H13
H11
H9
H7
H4
G30
G27
F32
F29
F28
F27
F26
F24
F22
F20
F18
F16
F14
F12
F10
F8
F6
F3
E30
E2
D32
D30
D29
D27
D25
D23
D21
D19
D17
D15
D13
D11
D9
D7
B6
D1
C31
C30
B30
B28
B26
B24
B22
B20
B18
B16
B14
B12
B10
B8
D2
C2
A30
AK33
AC23
AC22
AB23
NB_A30
NB_AK33
VCC3
VFSB15
VSM15
VCC1.5
VCC1.5
VCAP3
VCAP2
VCAP1
U9G
(INTEL-RG82875-A2)
Y20
VCC
Y18
VCC
Y16
VCC
Y14
VCC
W19
VCC
W17
VCC
W15
VCC
V20
VCC
V18
VCC
V16
VCC
V14
VCC
V11
VCC
U19
VCC
U17
VCC
U15
VCC
U11
VCC
T20
VCC
T18
VCC
T16
VCC
T14
VCC
T11
VCC
T10
VCC
R19
VCC
R17
VCC
R15
VCC
R11
VCC
R10
VCC
P20
VCC
P18
VCC
P16
VCC
P14
VCC
P11
VCC
P10
VCC
P9
VCC
N11
VCC
N10
VCC
N9
VCC
N8
VCC
N7
VCC
M11
VCC
M10
VCC
M9
VCC
M8
VCC
M7
VCC
M6
VCC
L11
VCC
L10
VCC
L9
VCC
L8
VCC
L7
VCC
L6
VCC
L5
VCC
K6
VCC
K5
VCC
J6
VCC
J5
VCC
AE1
VCC_AGP
AA1
VCC_AGP
T1
VCC_AGP
N4
VCC_AGP
N3
VCC_AGP
M4
VCC_AGP
M3
VCC_AGP
M2
VCC_AGP
L4
VCC_AGP
L3
VCC_AGP
L2
VCC_AGP
L1
VCC_AGP
K4
VCC_AGP
K3
VCC_AGP
K2
VCC_AGP
K1
VCC_AGP
J4
VCC_AGP
J3
VCC_AGP
J2
VCC_AGP
J1
VCC_AGP
H3
VCC_AGP
H2
VCC_AGP
H1
VCC_AGP
G3
VCC_AGP
G2
VCC_AGP
G1
VCC_AGP
F1
VCC_AGP
F2
VCCA_AGP
E1
VCCA_AGP
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCC_DDR
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
VCCHI
AN30
AN22
AN18
AN11
AN10
AM12
AM11
AM10
AL12
AL11
AL10
AK12
AK11
AK10
AJ12
AJ11
AJ10
AH12
AH11
AH10
AG12
AG11
AG10
AF12
AF11
AF10
AE15
AE12
AE11
AE10
AD33
AD24
AD22
AD20
AD18
AD16
AD14
AD12
AD11
AD10
AC21
AC19
AC17
AC15
AC13
AC12
AC11
AC10
AB24
AA23
Y24
W23
V24
U23
T24
R23
P33
P24
N23
D33
AN8
AN5
AA10
Y11
Y10
Y9
W11
W10
W9
V10
V9
U10
U9
T9
T8
T7
R9
R8
R7
R6
R5
P8
P7
P6
P5
N6
N5
M5
V25_CAP6
V25_CAP4
V25_CAP2
V25_CAP3
V25_CAP1
V25_CAP5
NB_AN8
VCAP4
VDIMM
V25_CAP3
VDIMM
V25_CAP1
VDIMM
VCC1.5
U9F
(INTEL-RG82875-A2)
AM29
VSS
AM26
VSS
AM23
VSS
AM20
VSS
AM17
VSS
AM14
VSS
AM9
VSS
AM7
VSS
AM5
VSS
AM3
VSS
AL31
VSS
AL6
VSS
AL3
VSS
AL2
VSS
AK27
VSS
AK25
VSS
AK19
VSS
AK17
VSS
AK15
VSS
AK8
VSS
AK4
VSS
AJ32
VSS
AJ30
VSS
AJ9
VSS
AJ7
VSS
AJ5
VSS
AJ2
VSS
AH28
VSS
AH22
VSS
AH18
VSS
AH14
VSS
AH6
VSS
AH4
VSS
AH3
VSS
AG7
VSS
AG5
VSS
AG2
VSS
AF32
VSS
AF30
VSS
AF26
VSS
AF23
VSS
AF20
VSS
AF17
VSS
AF15
VSS
AF13
VSS
AF9
VSS
AF8
VSS
AF4
VSS
AE24
VSS
AE22
VSS
AE20
VSS
AE18
VSS
AE16
VSS
AE14
VSS
AE6
VSS
AE2
VSS
AD28
VSS
AD25
VSS
AD23
VSS
AD21
VSS
AD19
VSS
AD17
VSS
AD15
VSS
AD13
VSS
AD9
VSS
AD7
VSS
AD4
VSS
AC32
VSS
AC30
VSS
AC24
VSS
AC20
VSS
AC18
VSS
AC16
VSS
AC14
VSS
AC6
VSS
AC2
VSS
AB28
VSS
AB25
VSS
AB11
VSS
AB10
VSS
AB9
VSS
AB8
VSS
AB4
VSS
AA26
VSS
AA24
VSS
AA11
VSS
AA9
VSS
AA6
VSS
AA2
VSS
GND
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
Y32
Y30
Y28
Y25
Y23
Y19
Y17
Y15
Y8
Y4
W26
W24
W20
W18
W16
W14
W6
W2
V32
V28
V25
V23
V19
V17
V15
V8
V4
U26
U24
U20
U18
U16
U14
U6
U2
T28
T25
T23
T19
T17
T15
T4
R32
R30
R24
R20
R18
R16
R14
R2
P28
P25
P23
P19
P17
P15
P4
P3
N30
N24
N2
M32
M28
M25
M24
M23
M1
L26
L24
L23
L12
K32
K28
K25
K24
K23
K22
K21
K20
K19
K18
K17
K16
K15
K14
K13
K7
J30
J26
VCC1.5
VCC1.5
VDIMM
VCC1.5
NB_A30
NB_AK33
NB_AN8
VTT_CAP4
VTT_CAP1
VTT_CAP2
VTT_CAP3
VCAP4
CB4
C1U16Y0805
CB15
C1U16Y0805
C133 C0.1U50Y
C177 C0.1U50Y
C226 C0.1U50Y
C144 C0.1U50Y
C151 C0.1U50Y
C157 C0.1U50Y
C165 C0.1U50Y
C234 C0.1U50Y
U9_X1
HS_HOOK
CP15
X_COPPER
L7
X_0.82U35m-2
CP16
X_COPPER
L8
X_60L3_30_0805
CB17
C1U16Y0805
CB16
C4.7U10Y0805
NB_HEATSINK
VFSB15
C182
C0.1U50Y
VSM15
C195
C0.1U50Y
CB9
C1U16Y
CB11
X_C1U10Y
VCAP3
VCAP2
VCAP1
V25_CAP1
V25_CAP2
V25_CAP3
V25_CAP4
V25_CAP5
V25_CAP6
VTT_NB
VTT_NB
C91
C0.1U50Y
C173
C0.1U50Y
C227 C0.1U50Y
C217 C0.1U50Y
C208 C0.1U50Y
C146 C0.1U50Y
C211 C0.1U50Y
C167 C0.1U50Y
C199 C0.1U50Y
C127 C0.1U50Y
C183 C0.1U50Y
U9_X2
HS_HOOK
CB8
C1U16Y0805
C179
C0.1U50Y
C247
C0.1U50Y
C186
C0.1U50Y
CB10
X_C4.7U10Y0805
C176
C0.1U50Y
C28
C0.1U50Y
C279
C0.1U50Y
C155
X_C0.1U50Y
C57
C0.1U50Y
C265
C0.1U50Y
Title
MS-6758
Size Document Number Rev
Intel I875P Power and Ground 20D
5
4
3
2
Date: Sheet
1
11 29Friday, February 13, 2004
of
Page 12

5
D D
4
3
2
1
AGPRST# changed to SLOT_RST#
AGP1
B1
OVRCNT#
VCC
VCC
AGP_REQ9
AGP_ST09
AGP_ST29
AGP_RBF9
VCC3
VCC3
3VDU
VCC3
VCC3
VCC1.5
VCC1.5
VCC1.5
VCC1.5
VCC1.5
VCC1.5
VCC1.5
PCI_IRQ#B
AGP_CLK66
AGP_REQ
AGP_ST0
AGP_ST2
AGP_RBF
AGP_DBIL
AGP_SBA#0
AGP_SBA#2
AGP_SBSTBF
AGP_SBA#4
AGP_SBA#6
AGP_AD31
AGP_AD29
AGP_AD27
AGP_AD25
AGP_ADSTBF1
AGP_AD23
AGP_AD21
AGP_AD19
AGP_AD17
AGP_CBE2
AGP_IRDY
AGP_DEVSEL
AGP_PERR#
R226 6.8KR
AGP_CBE1
AGP_AD14
AGP_AD10
AGP_AD8
AGP_ADSTBF0
AGP_AD7
AGP_AD5
AGP_AD3
AGP_AD1
AGP_VREF
C259
C0.1U50Y
PCI_IRQ#B16,19,20,21
AGP_CLK666
AGP_DBIL9
AGP_SBSTBF9
C C
AGP_ADSTBF19
AGP_CBE29
AGP_IRDY9
AGP_DEVSEL9
AGP_CBE19
B B
AGP_ADSTBF09
B2
5V
B3
5V
B4
USB+
B5
GND
B6
INTB#
B7
CLK
B8
REQ#
B9
VCC3
B10
ST0
B11
ST2
B12
RBF#
B13
GND
B14
RESV
B15
SBA0
B16
VCC3
B17
SBA2
B18
SB_STB
B19
GND
B20
SBA4
B21
SBA6
B22
RESV
B23
GND N
B24
3_3VAUX1
B25
VCC3
B26
AD31
B27
AD29
B28
VCC3
B29
AD27
B30
AD25
B31
GND
B32
AD_STB1
B33
AD23
B34
VDDQ
B35
AD21
B36
AD19
B37
GND
B38
AD17
B39
C/BE#2
B40
VDDQ
B41
IRDY#
B46
DEVSEL#
B47
VDDQ
B48
PERR#
B49
GND
B50
SERR#
B51
C/BE#1
B52
VDDQ
B53
AD14
B54
AD12
B55
GND
B56
AD10
B57
AD8
B58
VDDQ
B59
AD_STB0
B60
AD7
B61
GND
B62
AD5
B63
AD3
B64
VDDQ
B65
AD1
B66
VREF_CG
SLOT-AGP1.5LATCH_red
TYPEDET#
RESV
USBGND
INTA#
RST#
GNT#
VCC3
RESV
PIPE#
GND
WBF#
SBA1
VCC3
SBA3
ST_STB#
GND
SBA5
SBA7
RESV_C
GND_D
RESV_D
VCC3_3_C
AD30
AD28
VCC3
AD26
AD24
GND
AD_STB1#
C/BE#3
VDDQ
AD22
AD20
GND
AD18
AD16
VDDQ
FRAME#
TRDY#
STOP#
PME#
GND
AD15
VDDQ
AD13
AD11
GND
C/BE#0
VDDQ
AD_STB0#
GND
VDDQ
VREF_GC
PAR
ST1
AD9
AD6
AD4
AD2
AD0
A1
12V
A2
GC_DET#
A3
A4
A5
PCI_IRQ#A
A6
SLOT_RST#
A7
AGP_GNT
A8
A9
AGP_ST1
A10
A11
AGP_DBIH
A12
A13
AGP_WBF
A14
AGP_SBA#1
A15
A16
AGP_SBA#3
A17
AGP_SBSTBS
A18
A19
AGP_SBA#5
A20
AGP_SBA#7
A21
A22
A23
A24
A25
AGP_AD30
A26
AGP_AD28
A27
A28
AGP_AD26
A29
AGP_AD24
A30
A31
AGP_ADSTBS1
A32
AGP_CBE3
A33
A34
AGP_AD22
A35
AGP_AD20
A36
A37
AGP_AD18
A38
AGP_AD16
A39
A40
AGP_FRAME
A41
AGP_TRDY
A46
AGP_STOP
A47
PCI_PME#
A48
A49
AGP_PAR
A50
AGP_AD15
A51
A52
AGP_AD13
A53
AGP_AD11AGP_AD12
A54
A55
AGP_AD9
A56
AGP_CBE0
A57
A58
AGP_ADSTBS0
A59
AGP_AD6
A60
A61
AGP_AD4
A62
AGP_AD2
A63
A64
AGP_AD0
A65
A66
+12V
PCI_IRQ#A 16,19,20,21
SLOT_RST# 19,20,21,27
AGP_GNT 9
VCC3
AGP_ST1 9
AGP_DBIH 9
AGP_WBF 9
VCC3
AGP_SBSTBS 9
VCC3
VCC3
AGP_ADSTBS1 9
AGP_CBE3 9
VCC1.5
VCC1.5
AGP_FRAME 9
AGP_TRDY 9
AGP_STOP 9
PCI_PME# 16,19,20,21
AGP_PAR 9
VCC1.5
AGP_CBE0 9
VCC1.5
AGP_ADSTBS0 9
VCC1.5
GC_DET#
Q27
N-MMBT3904_SOT23
AGP_AD[31..0]
AGP_SBA#[7..0]
+12V
C248
X_C0.1U50Y
C188
C0.1U50Y
MSDATA25
MSCLK25
KBDATA25
KBCLK25
+12V
VCC1.5
C187
X_C0.1U50Y
MSDATA
MSCLK
KBDATA
KBCLK
R231
8.2KR
VCC1.5
R225
R234
8.2KR
8.2KR
AGP_AD[31..0] 9
AGP_SBA#[7..0] 9
VCC1.5
SMBus crossed power plane
Hub-Link crossed power plane
246
135
AGP_PERR#
DS
G
Q29
N-2N7002_SOT23
R232
100R
C2279 C0.1U50Y
C2280 C0.1U50Y
C2281 C0.1U50Y
C267
X_C0.1U50Y
L1 X_60L650m_50
L2 X_60L650m_50
L3 X_60L650m_50
L4 X_60L650m_50
8
RN1
8P4R-4.7KR
7
KBVCC
VCC1.5
0228 Modified
C269
C0.1U50Y
R174 60.4R1%
R227 44.2R1%
DS
G
Q28
N-2N7002_SOT23
C263
X_C0.1U50Y
VCC3
C260
C0.1U50Y
246
135
3VDU
C262
C0.1U50Y
VCC1.5
C276
X_C0.1U50Y
7
8
11
12
1
2
5
6
8
CN1
8P4C-220P50N
7
KBMS1
CONN-KB_MS
MS
KB
AGP_VSWING
R178
39.2R1%
AGP_VREF
R228
100R1%
JTEST2
1
2
X_D1x2-BK
VCC
VCC3
10
C3
9
C0.1U50Y
4
3
AGP_VSWING 9
C221
C0.1U50Y
AGP_VREF 9
C224
C0.1U50Y
VCC
C294 C0.1U50Y
C261 X_C0.1U50Y
C264 C0.1U50Y
C388 X_C0.1U50Y
C62 X_C0.1U50Y
C68 C0.1U50Y
EC3
C10U16EL
JTEST1
1
2
X_D1x2-BK
+
12
KBVCC
A A
Title
MS-6758
Size Document Number Rev
AGP Slot and Kebord/Mouse Connector 20D
5
4
3
2
Date: Sheet
1
12 29Friday, February 13, 2004
of
Page 13

5
4
3
2
1
D D
DDRA_BANKA010,15
DDRA_BANKA110,15
DDRA_CS010,15
DDRA_CS110,15
C C
DDRA_WE10,15
DDRA_CAS10,15
DDRA_RAS10,15
DDRA_CKE010,15
DDRA_CKE110,15
B B
SMBDATA6,14,17,21,25,27
SMBCLK6,14,17,21,25,27
A0 A2
VREF_DIMM
VCC3
DDRA_MAA0
DDRA_MAA1
DDRA_MAA2
DDRA_MAA3
DDRA_MAA4
DDRA_MAA5
DDRA_MAA6
DDRA_MAA7
DDRA_MAA8
DDRA_MAA9
DDRA_MAA10
DDRA_MAA11
DDRA_MAA12
DDRA_BANKA0
DDRA_BANKA1
DDRA_CS0
DDRA_CS1
DDRA_WE
DDRA_CAS
DDRA_RAS
DDRA_CKE0
DDRA_CKE1
DDRA_CLK0
DDRA_CLK#0
DDRA_CLK1
DDRA_CLK#1
DDRA_CLK2
DDRA_CLK#2
DDRA_DQS0
DDRA_DQS1
DDRA_DQS2
DDRA_DQS3
DDRA_DQS4
DDRA_DQS5
DDRA_DQS6
DDRA_DQS7
DDRA_DQS8
SMBDATA
SMBCLK
CB2
X_C0.1U50Y
VDIMM
130
125
122
141
118
115
167
113
157
158
163
107
119
129
149
159
169
177
140
154
111
137
138
181
182
183
184
101
102
173
103
48
43
41
37
32
29
27
59
52
71
97
63
65
21
16
17
76
75
5
14
25
36
56
67
78
86
47
91
92
1
82
9
10
15223054627796
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
BA0
BA1
BA2
CS0
CS1
NC/CS2
NC/CS3
DQM0
DQM1
DQM2
DQM3
DQM4
DQM5
DQM6
DQM7
DQM8
WE
CAS
RAS
CKE0
CKE1
CK0
CK0
CK1/DNU
CK1/DNU
CK2/DNU
CK2/DNU
DQS0
DQS1
DQS2
DQS3
DQS4
DQS5
DQS6
DQS7
DQS8
SDA
SCL
SA0
SA1
SA2
VREF
VDDID
VDDSPD
NC
NC
NC
NC
NC
NC/FETEN
VDDQ
VDDQ
VDDQ
104
112
128
136
143
156
164
172
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
PC2700
Pin 167: A13
Pin 103: NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
3111826344250586674818993
180738467085108
VDD
VDD
VDD
VDD
VDDQ
VDDQ
GND
GND
GND
GND
GND
GND
GND
100
116
124
132
139
145
VDD
GND
VDD
GND
152
120
148
168
VDD
VDD
VDD
D10
D11
D12
D13
D14
D15
D16
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26
D27
D28
D29
D30
D31
D32
D33
D34
D35
D36
D37
D38
D39
D40
D41
D42
D43
D44
D45
D46
D47
D48
D49
D50
D51
D52
D53
D54
D55
D56
D57
D58
D59
D60
D61
D62
D63
CB0
CB1
CB2
CB3
CB4
CB5
CB6
CB7
GND
GND
DIMM-184_green
160
176
DIMM1
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
WP
2
4
6
8
94
95
98
99
12
13
19
20
105
106
109
110
23
24
28
31
114
117
121
123
33
35
39
40
126
127
131
133
53
55
57
60
146
147
150
151
61
64
68
69
153
155
161
162
72
73
79
80
165
166
170
171
83
84
87
88
174
175
178
179
44
45
49
51
134
135
142
144
90
DDRA_MD0
DDRA_MD1
DDRA_MD2
DDRA_MD3
DDRA_MD4
DDRA_MD5
DDRA_MD6
DDRA_MD7
DDRA_MD8
DDRA_MD9
DDRA_MD10
DDRA_MD11
DDRA_MD12
DDRA_MD13
DDRA_MD14
DDRA_MD15
DDRA_MD16
DDRA_MD17
DDRA_MD18
DDRA_MD19
DDRA_MD20
DDRA_MD21
DDRA_MD22
DDRA_MD23
DDRA_MD24
DDRA_MD25
DDRA_MD26
DDRA_MD27
DDRA_MD28
DDRA_MD29
DDRA_MD30
DDRA_MD31
DDRA_MD32
DDRA_MD33
DDRA_MD34
DDRA_MD35
DDRA_MD36
DDRA_MD37
DDRA_MD38
DDRA_MD39
DDRA_MD40
DDRA_MD41
DDRA_MD42
DDRA_MD43
DDRA_MD44
DDRA_MD45
DDRA_MD46
DDRA_MD47
DDRA_MD48
DDRA_MD49
DDRA_MD50
DDRA_MD51
DDRA_MD52
DDRA_MD53
DDRA_MD54
DDRA_MD55
DDRA_MD56
DDRA_MD57
DDRA_MD58
DDRA_MD59
DDRA_MD60
DDRA_MD61
DDRA_MD62
DDRA_MD63
DDRA_ECC0
DDRA_ECC1
DDRA_ECC2
DDRA_ECC3
DDRA_ECC4
DDRA_ECC5
DDRA_ECC6
DDRA_ECC7
R17 4.7KR
SPD_WP#
VCC3
SPD_WP# 14
DDRA_BANKA010,15
DDRA_BANKA110,15
DDRA_CS210,15
DDRA_CS310,15
DDRA_WE10,15
DDRA_CAS10,15
DDRA_RAS10,15
DDRA_CKE210,15
DDRA_CKE310,15
VREF_DIMM
VCC3
VCC3
DDRA_MAA0
DDRA_MAA1
DDRA_MAA2
DDRA_MAA3
DDRA_MAA4
DDRA_MAA5
DDRA_MAA6
DDRA_MAA7
DDRA_MAA8
DDRA_MAA9
DDRA_MAA10
DDRA_MAA11
DDRA_MAA12
DDRA_BANKA0
DDRA_BANKA1
DDRA_CS2
DDRA_CS3
DDRA_WE
DDRA_CAS
DDRA_RAS
DDRA_CKE2
DDRA_CKE3
DDRA_CLK3
DDRA_CLK#3
DDRA_CLK4
DDRA_CLK#4
DDRA_CLK5
DDRA_CLK#5
DDRA_DQS0
DDRA_DQS1
DDRA_DQS2
DDRA_DQS3
DDRA_DQS4
DDRA_DQS5
DDRA_DQS6
DDRA_DQS7
DDRA_DQS8
SMBDATA
SMBCLK
VDIMM
130
125
122
141
118
115
167
113
157
158
163
107
119
129
149
159
169
177
140
154
111
137
138
181
182
183
184
101
102
173
103
48
43
41
37
32
29
27
59
52
71
97
63
65
21
16
17
76
75
14
25
36
56
67
78
86
47
91
92
82
10
5
1
9
15223054627796
VDDQ
VDDQ
VDDQ
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
BA0
BA1
BA2
CS0
CS1
NC/CS2
NC/CS3
DQM0
DQM1
DQM2
DQM3
DQM4
DQM5
DQM6
DQM7
DQM8
WE
CAS
RAS
CKE0
CKE1
CK0
CK0
CK1/DNU
CK1/DNU
CK2/DNU
CK2/DNU
DQS0
DQS1
DQS2
DQS3
DQS4
DQS5
DQS6
DQS7
DQS8
SDA
SCL
SA0
SA1
SA2
VREF
VDDID
VDDSPD
NC
NC
NC
NC
NC
NC/FETEN
3111826344250586674818993
VDDQ
GND
VDDQ
GND
104
112
VDDQ
VDDQ
VDDQ
VDDQ
PC2700
Pin 167: A13
Pin 103: NC
GND
GND
GND
GND
128
VDDQ
GND
136
VDDQ
GND
143
VDDQ
GND
156
164
172
180738467085108
VDDQ
VDDQ
VDDQ
VDDQ
GND
GND
GND
GND
DIMM2
120
148
168
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
GND
GND
GND
GND
GND
GND
GND
GND
GND
100
116
124
DIMM-184_green
132
139
145
152
160
176
D10
D11
D12
D13
D14
D15
D16
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26
D27
D28
D29
D30
D31
D32
D33
D34
D35
D36
D37
D38
D39
D40
D41
D42
D43
D44
D45
D46
D47
D48
D49
D50
D51
D52
D53
D54
D55
D56
D57
D58
D59
D60
D61
D62
D63
CB0
CB1
CB2
CB3
CB4
CB5
CB6
CB7
DDRA_MD0
2
D0
DDRA_MD1
4
D1
DDRA_MD2
6
D2
DDRA_MD3
8
D3
DDRA_MD4
94
D4
DDRA_MD5
95
D5
DDRA_MD6
98
D6
DDRA_MD7
99
D7
DDRA_MD8
12
D8
DDRA_MD9
13
D9
DDRA_MD10
19
DDRA_MD11
20
DDRA_MD12
105
DDRA_MD13
106
DDRA_MD14
109
DDRA_MD15
110
DDRA_MD16
23
DDRA_MD17
24
DDRA_MD18
28
DDRA_MD19
31
DDRA_MD20
114
DDRA_MD21
117
DDRA_MD22
121
DDRA_MD23
123
DDRA_MD24
33
DDRA_MD25
35
DDRA_MD26
39
DDRA_MD27
40
DDRA_MD28
126
DDRA_MD29
127
DDRA_MD30
131
DDRA_MD31
133
DDRA_MD32
53
DDRA_MD33
55
DDRA_MD34
57
DDRA_MD35
60
DDRA_MD36
146
DDRA_MD37
147
DDRA_MD38
150
DDRA_MD39
151
DDRA_MD40
61
DDRA_MD41
64
DDRA_MD42
68
DDRA_MD43
69
DDRA_MD44
153
DDRA_MD45
155
DDRA_MD46
161
DDRA_MD47
162
DDRA_MD48
72
DDRA_MD49
73
DDRA_MD50
79
DDRA_MD51
80
DDRA_MD52
165
DDRA_MD53
166
DDRA_MD54
170
DDRA_MD55
171
DDRA_MD56
83
DDRA_MD57
84
DDRA_MD58
87
DDRA_MD59
88
DDRA_MD60
174
DDRA_MD61
175
DDRA_MD62
178
DDRA_MD63
179
DDRA_ECC0
44
DDRA_ECC1
45
DDRA_ECC2
49
DDRA_ECC3
51
DDRA_ECC4
134
DDRA_ECC5
135
DDRA_ECC6
142
DDRA_ECC7
144
SPD_WP#
90
WP
A A
5
DDRA_MAA[12..0]
DDRA_CLK[5..0]
DDRA_CLK#[5..0]
DDRA_DQS[8..0]
DDRA_MD[63..0]
DDRA_ECC[7..0]
DDRA_MAA[12..0] 10,15
DDRA_CLK[5..0] 10
DDRA_CLK#[5..0] 10
DDRA_DQS[8..0] 10,15
DDRA_MD[63..0] 10,15
DDRA_ECC[7..0] 10,15
VDIMM
C55
C48
C93
C105
X_C0.1U50Y
C0.1U50Y
C0.1U50Y
4
C0.1U50Y
C131
C0.1U50Y
Title
MS-6758
Size Document Number Rev
DDR Memory Channel A 20D
3
2
Date: Sheet
1
13 29Friday, February 13, 2004
of
Page 14

5
4
3
2
1
DDRB_MAB0
DDRB_MAB1
DDRB_MAB2
DDRB_MAB3
DDRB_MAB4
DDRB_MAB5
DDRB_MAB6
DDRB_MAB7
DDRB_MAB8
DDRB_MAB9
DDRB_MAB10
DDRB_MAB11
DDRB_MAB12
DDRB_BANKB0
DDRB_BANKB1
DDRB_CS0
DDRB_CS1
DDRB_WE
DDRB_CAS
DDRB_RAS
DDRB_CKE0
DDRB_CKE1
DDRB_CLK0
DDRB_CLK#0
DDRB_CLK1
DDRB_CLK#1
DDRB_CLK2
DDRB_CLK#2
DDRB_DQS0
DDRB_DQS1
DDRB_DQS2
DDRB_DQS3
DDRB_DQS4
DDRB_DQS5
DDRB_DQS6
DDRB_DQS7
DDRB_DQS8
SMBDATA
SMBCLK
VCC3
CB3
X_C0.1U50Y
VDIMM
139
VDD
GND
145
VDD
GND
120
VDD
GND
152
160
DIMM3
148
168
VDD
VDD
VDD
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26
D27
D28
D29
D30
D31
D32
D33
D34
D35
D36
D37
D38
D39
D40
D41
D42
D43
D44
D45
D46
D47
D48
D49
D50
D51
D52
D53
D54
D55
D56
D57
D58
D59
D60
D61
D62
D63
CB0
CB1
CB2
CB3
CB4
CB5
CB6
CB7
WP
GND
GND
DIMM-184_purple
176
2
4
6
8
94
95
98
99
12
13
19
20
105
106
109
110
23
24
28
31
114
117
121
123
33
35
39
40
126
127
131
133
53
55
57
60
146
147
150
151
61
64
68
69
153
155
161
162
72
73
79
80
165
166
170
171
83
84
87
88
174
175
178
179
44
45
49
51
134
135
142
144
90
DDRB_MD0
DDRB_MD1
DDRB_MD2
DDRB_MD3
DDRB_MD4
DDRB_MD5
DDRB_MD6
DDRB_MD7
DDRB_MD8
DDRB_MD9
DDRB_MD10
DDRB_MD11
DDRB_MD12
DDRB_MD13
DDRB_MD14
DDRB_MD15
DDRB_MD16
DDRB_MD17
DDRB_MD18
DDRB_MD19
DDRB_MD20
DDRB_MD21
DDRB_MD22
DDRB_MD23
DDRB_MD24
DDRB_MD25
DDRB_MD26
DDRB_MD27
DDRB_MD28
DDRB_MD29
DDRB_MD30
DDRB_MD31
DDRB_MD32
DDRB_MD33
DDRB_MD34
DDRB_MD35
DDRB_MD36
DDRB_MD37
DDRB_MD38
DDRB_MD39
DDRB_MD40
DDRB_MD41
DDRB_MD42
DDRB_MD43
DDRB_MD44
DDRB_MD45
DDRB_MD46
DDRB_MD47
DDRB_MD48
DDRB_MD49
DDRB_MD50
DDRB_MD51
DDRB_MD52
DDRB_MD53
DDRB_MD54
DDRB_MD55
DDRB_MD56
DDRB_MD57
DDRB_MD58
DDRB_MD59
DDRB_MD60
DDRB_MD61
DDRB_MD62
DDRB_MD63
DDRB_ECC0
DDRB_ECC1
DDRB_ECC2
DDRB_ECC3
DDRB_ECC4
DDRB_ECC5
DDRB_ECC6
DDRB_ECC7
SPD_WP#
SPD_WP# 13
DDRB_BANKB010,15
DDRB_BANKB110,15
DDRB_CS210,15
DDRB_CS310,15
DDRB_WE10,15
DDRB_CAS10,15
DDRB_RAS10,15
DDRB_CKE210,15
DDRB_CKE310,15
VREF_DIMM
VCC3
VCC3
VCC3
15223054627796
48
VDDQ
A0
43
A1
41
A2
130
A3
37
A4
32
A5
125
A6
29
A7
122
A8
27
A9
141
A10
118
A11
115
A12
167
A13
59
BA0
52
BA1
113
BA2
157
CS0
158
CS1
71
NC/CS2
163
NC/CS3
97
DQM0
107
DQM1
119
DQM2
129
DQM3
149
DQM4
159
DQM5
169
DQM6
177
DQM7
140
DQM8
63
WE
65
CAS
154
RAS
21
CKE0
111
CKE1
137
CK0
138
CK0
16
CK1/DNU
17
CK1/DNU
76
CK2/DNU
75
CK2/DNU
5
DQS0
14
DQS1
25
DQS2
36
DQS3
56
DQS4
67
DQS5
78
DQS6
86
DQS7
47
DQS8
91
SDA
92
SCL
181
SA0
182
SA1
183
SA2
1
VREF
82
VDDID
184
VDDSPD
9
NC
10
NC
101
NC
102
NC
173
NC
103
NC/FETEN
104
112
128
136
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
PC2700
Pin 167: A13
Pin 103: NC
GND
GND
GND
GND
GND
GND
GND
GND
3111826344250586674818993
143
156
VDDQ
GND
164
VDDQ
GND
VDDQ
GND
172
180738467085108
VDD
VDD
VDD
VDDQ
VDDQ
GND
GND
GND
GND
GND
GND
100
116
124
132
D D
DDRB_BANKB010,15
DDRB_BANKB110,15
DDRB_CS010,15
DDRB_CS110,15
C C
DDRB_WE10,15
DDRB_CAS10,15
DDRB_RAS10,15
DDRB_CKE010,15
DDRB_CKE110,15
B B
VCC3
SMBDATA6,13,17,21,25,27
SMBCLK6,13,17,21,25,27
A4 A6
VREF_DIMM
DDRB_MAB0
DDRB_MAB1
DDRB_MAB2
DDRB_MAB3
DDRB_MAB4
DDRB_MAB5
DDRB_MAB6
DDRB_MAB7
DDRB_MAB8
DDRB_MAB9
DDRB_MAB10
DDRB_MAB11
DDRB_MAB12
DDRB_BANKB0
DDRB_BANKB1
DDRB_CS2
DDRB_CS3
DDRB_WE
DDRB_CAS
DDRB_RAS
DDRB_CKE2
DDRB_CKE3
DDRB_CLK3
DDRB_CLK#3
DDRB_CLK4
DDRB_CLK#4
DDRB_CLK5
DDRB_CLK#5
DDRB_DQS0
DDRB_DQS1
DDRB_DQS2
DDRB_DQS3
DDRB_DQS4
DDRB_DQS5
DDRB_DQS6
DDRB_DQS7
DDRB_DQS8
SMBDATA
SMBCLK
VDIMM
139
VDD
GND
VDD
GND
145
152
VDD
GND
120
148
VDD
VDD
GND
GND
160
176
DIMM4
168
VDD
2
D0
4
D1
6
D2
8
D3
94
D4
95
D5
98
D6
99
D7
12
D8
13
D9
19
D10
20
D11
105
D12
106
D13
109
D14
110
D15
23
D16
24
D17
28
D18
31
D19
114
D20
117
D21
121
D22
123
D23
33
D24
35
D25
39
D26
40
D27
126
D28
127
D29
131
D30
133
D31
53
D32
55
D33
57
D34
60
D35
146
D36
147
D37
150
D38
151
D39
61
D40
64
D41
68
D42
69
D43
153
D44
155
D45
161
D46
162
D47
72
D48
73
D49
79
D50
80
D51
165
D52
166
D53
170
D54
171
D55
83
D56
84
D57
87
D58
88
D59
174
D60
175
D61
178
D62
179
D63
44
CB0
45
CB1
49
CB2
51
CB3
134
CB4
135
CB5
142
CB6
144
CB7
90
WP
DIMM-184_purple
DDRB_MD0
DDRB_MD1
DDRB_MD2
DDRB_MD3
DDRB_MD4
DDRB_MD5
DDRB_MD6
DDRB_MD7
DDRB_MD8
DDRB_MD9
DDRB_MD10
DDRB_MD11
DDRB_MD12
DDRB_MD13
DDRB_MD14
DDRB_MD15
DDRB_MD16
DDRB_MD17
DDRB_MD18
DDRB_MD19
DDRB_MD20
DDRB_MD21
DDRB_MD22
DDRB_MD23
DDRB_MD24
DDRB_MD25
DDRB_MD26
DDRB_MD27
DDRB_MD28
DDRB_MD29
DDRB_MD30
DDRB_MD31
DDRB_MD32
DDRB_MD33
DDRB_MD34
DDRB_MD35
DDRB_MD36
DDRB_MD37
DDRB_MD38
DDRB_MD39
DDRB_MD40
DDRB_MD41
DDRB_MD42
DDRB_MD43
DDRB_MD44
DDRB_MD45
DDRB_MD46
DDRB_MD47
DDRB_MD48
DDRB_MD49
DDRB_MD50
DDRB_MD51
DDRB_MD52
DDRB_MD53
DDRB_MD54
DDRB_MD55
DDRB_MD56
DDRB_MD57
DDRB_MD58
DDRB_MD59
DDRB_MD60
DDRB_MD61
DDRB_MD62
DDRB_MD63
DDRB_ECC0
DDRB_ECC1
DDRB_ECC2
DDRB_ECC3
DDRB_ECC4
DDRB_ECC5
DDRB_ECC6
DDRB_ECC7
SPD_WP#
15223054627796
48
A0
43
A1
41
A2
130
A3
37
A4
32
A5
125
A6
29
A7
122
A8
27
A9
141
A10
118
A11
115
A12
167
A13
59
BA0
52
BA1
113
BA2
157
CS0
158
CS1
71
NC/CS2
163
NC/CS3
97
DQM0
107
DQM1
119
DQM2
129
DQM3
149
DQM4
159
DQM5
169
DQM6
177
DQM7
140
DQM8
63
WE
65
CAS
154
RAS
21
CKE0
111
CKE1
137
CK0
138
CK0
16
CK1/DNU
17
CK1/DNU
76
CK2/DNU
75
CK2/DNU
5
DQS0
14
DQS1
25
DQS2
36
DQS3
56
DQS4
67
DQS5
78
DQS6
86
DQS7
47
DQS8
91
SDA
92
SCL
181
SA0
182
SA1
183
SA2
1
VREF
82
VDDID
184
VDDSPD
9
NC
10
NC
101
NC
102
NC
173
NC
103
NC/FETEN
104
112
128
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
PC2700
Pin 167: A13
Pin 103: NC
GND
GND
GND
GND
GND
GND
3111826344250586674818993
136
VDDQ
GND
VDDQ
GND
143
VDDQ
GND
156
VDDQ
GND
164
VDDQ
GND
172
180738467085108
VDD
VDD
VDD
VDDQ
VDDQ
GND
GND
GND
GND
GND
GND
100
116
124
132
DDRB_DQS[8..0]
A A
5
DDRB_MD[63..0]
DDRB_ECC[7..0]
DDRB_MAB[12..0]
DDRB_CLK[5..0]
DDRB_CLK#[5..0]
DDRB_DQS[8..0] 10,15
DDRB_MD[63..0] 10,15
DDRB_ECC[7..0] 10,15
DDRB_MAB[12..0] 10,15
DDRB_CLK[5..0] 10
DDRB_CLK#[5..0] 10
4
C25
X_C0.1U50Y
C69
C0.1U50Y
C166
C0.1U50Y
C17
C0.1U50Y
3
C153
C0.1U50Y
VDIMM VREF_DIMMVDIMM
R159 150R1%
R158
150R1%
C219
C216
C0.1U50Y
C0.1U50Y
Title
MS-6758
Size Document Number Rev
DDR Memory Channel B 20D
2
Date: Sheet
1
14 29Friday, February 13, 2004
of
Page 15

5
4
3
2
1
VTT_DDR
R116 47R
R118 47R
RN49
1
2
3
4
5
6
7
8
8P4R-47R
R126 47R
RN42
1
2
3
4
5
6
7
8
8P4R-47R
R105 47R
R98 47R
R101 47R
R92 47R
R93 47R
RN29
1
2
3
4
5
6
7
8
8P4R-47R
R73 47R
R55 47R
R63 47R
R66 47R
RN15
1
2
3
4
5
6
7
8
8P4R-47R
DDRB_MD1
DDRB_MD5
DDRB_MD4
DDRB_MD0
DDRB_MD2
DDRB_MD6
DDRB_DQS0
DDRB_MD9
DDRB_MD8
DDRB_MD3
DDRB_MD7
DDRB_MD13
DDRB_DQS1
DDRB_MD12
DDRB_MD11
DDRB_MD10
DDRB_MD15
DDRB_MD14
DDRB_DQS2
DDRB_MD17
DDRB_MD16
DDRB_MD20
DDRB_MD22
DDRB_MD18
DDRB_MD21
DDRB_MD28
DDRB_MD24
DDRB_MD19
DDRB_MD23
RN60
1
3
5
7
8P4R-56R
RN58
1
3
5
7
8P4R-56R
RN56
1
3
5
7
8P4R-56R
RN52
1
3
5
7
8P4R-56R
RN50
1
3
5
7
8P4R-56R
RN47
1
3
5
7
8P4R-56R
RN44
1
3
5
7
8P4R-56R
RN41
1
3
5
7
8P4R-56R
RN39
2
DDRB_DQS3
4
DDRB_MD29
6
DDRB_MD25
8
DDRB_MD27
2
DDRB_MD31
4
DDRB_MD26
6
DDRB_MD30
8
DDRB_ECC1
2
DDRB_ECC0
4
DDRB_ECC4
6
DDRB_ECC5
8
DDRB_ECC7
2
DDRB_ECC3
4
DDRB_ECC6
6
DDRB_ECC2
8
DDRB_MD37
2
DDRB_MD33
4
DDRB_MD36
6
DDRB_MD32
8
DDRB_MD38
2
4
DDRB_MD34
6
DDRB_DQS4
8
DDRB_MD40
2
DDRB_MD44
4
DDRB_MD35
6
DDRB_MD39
8
DDRB_DQS5
2
DDRB_MD45
4
DDRB_MD42
6
DDRB_MD41
8
1
3
5
7
1
3
5
7
1
3
5
7
1
3
5
7
1
3
5
7
1
3
5
7
1
3
5
7
1
3
5
7
8P4R-56R
RN35
8P4R-56R
RN33
8P4R-56R
RN26
8P4R-56R
RN24
8P4R-56R
RN22
8P4R-56R
RN20
8P4R-56R
RN16
DDRB_MD47
2
DDRB_MD43
4
DDRB_MD46
6
8
DDRB_MD53
2
DDRB_MD52
4
DDRB_MD49
6
DDRB_MD48
8
DDRB_MD55
2
DDRB_DQS6
4
DDRB_MD54
6
8
DDRB_MD61
2
DDRB_MD60
4
DDRB_MD51
6
DDRB_MD50
8
DDRB_DQS7
2
4
DDRB_MD57
6
DDRB_MD56
8
DDRB_MD63
2
DDRB_MD59
4
DDRB_MD58
6
DDRB_MD62
8
DDRB_DQS8
2
4
6
8
2
4
6
8
8P4R-56R
D D
DDRA_MD1
DDRA_MD5
DDRA_MD4
DDRA_MD0
DDRA_MD6
DDRA_MD2
DDRA_DQS0
DDRA_MD9
DDRA_MD8
DDRA_MD3
DDRA_MD7
DDRA_MD13
DDRA_DQS1
DDRA_MD12
DDRA_MD11
C C
DDRA_MD10
DDRA_MD15
DDRA_MD14
DDRA_DQS2
DDRA_MD21
DDRA_MD17
DDRA_MD16
DDRA_MD25
DDRA_MD24
DDRA_MD19
DDRA_MD23
DDRA_MD30
DDRA_DQS3
DDRA_MD29
DDRA_MD28
RN59
1
3
5
7
8P4R-56R
RN57
1
3
5
7
8P4R-56R
RN55
1
3
5
7
8P4R-56R
RN53
1
3
5
7
8P4R-56R
RN51
1
3
5
7
8P4R-56R
RN46
1
3
5
7
8P4R-56R
RN40
1
3
5
7
8P4R-56R
RN38
1
3
5
7
DDRA_ECC4
2
DDRA_MD31
4
DDRA_MD27
6
DDRA_MD26
8
DDRA_DQS8
2
DDRA_ECC1
4
DDRA_ECC5
6
DDRA_ECC0
8
DDRA_ECC7
2
DDRA_ECC3
4
DDRA_ECC6
6
DDRA_ECC2
8
DDRA_MD37
2
DDRA_MD33
4
DDRA_MD36
6
DDRA_MD32
8
DDRA_MD38
2
4
DDRA_MD34
6
DDRA_DQS4
8
DDRA_MD40
2
DDRA_MD44
4
DDRA_MD35
6
DDRA_MD39
8
DDRA_MD46
2
DDRA_MD43
4
DDRA_MD42
6
DDRA_DQS5
8
DDRA_MD52
2
DDRA_MD49
4
DDRA_MD48
6
DDRA_MD47
8
8P4R-56R
RN34
1
3
5
7
8P4R-56R
RN31
1
3
5
7
8P4R-56R
RN25
1
3
5
7
8P4R-56R
RN23
1
3
5
7
8P4R-56R
RN21
1
3
5
7
8P4R-56R
RN19
1
3
5
7
8P4R-56R
RN13
1
3
5
7
8P4R-56R
RN10
1
3
5
7
8P4R-56R
VTT_DDRVTT_DDR
DDRA_MD55
2
DDRA_MD54
4
DDRA_DQS6
6
DDRA_MD53
8
DDRA_MD61
2
DDRA_MD60
4
DDRA_MD51
6
DDRA_MD50
8
DDRA_DQS7
2
DDRA_MD57
4
DDRA_MD56
6
8
DDRA_MD58
2
DDRA_MD59
4
DDRA_MD63
6
DDRA_MD62
8
DDRA_MD20
2
DDRA_MD22
4
DDRA_MD18
6
DDRA_MD41
8
DDRA_MD45
2
4
6
8
2
4
6
8
2
4
6
8
VTT_DDR
RN8
1
2
3
4
5
6
7
8
8P4R-56R
RN6
1
2
3
4
5
6
7
8
8P4R-56R
RN4
1
2
3
4
5
6
7
8
8P4R-56R
RN2
1
2
3
4
5
6
7
8
8P4R-56R
R128 56R
R114 56R
R115 56R
R59 56R
R61 56R
DDRA_CKE010,13
DDRA_CKE210,13
DDRA_CKE310,13
DDRA_CKE110,13
DDRA_BANKA110,13
DDRA_BANKA010,13
DDRA_CS010,13
DDRA_WE10,13
DDRA_RAS10,13
DDRA_CS310,13
DDRA_CS110,13
DDRA_CS210,13
DDRA_CAS10,13
DDRA_MAA[12..0]
DDRA_DQS[8..0]
DDRA_MD[63..0]
DDRA_ECC[7..0]
DDRA_MAA9
DDRA_MAA11
DDRA_CKE0
DDRA_CKE2
DDRA_CKE3
DDRA_CKE1
DDRA_MAA12
DDRA_MAA5
DDRA_MAA8
DDRA_MAA7
DDRA_MAA6
DDRA_MAA3
DDRA_MAA4
DDRA_MAA1
DDRA_MAA2
DDRA_BANKA1
DDRA_MAA10
DDRA_MAA0
DDRA_BANKA0
DDRA_CS0
DDRA_WE
DDRA_RAS
DDRA_CS3
DDRA_CS1
DDRA_CS2
DDRA_CAS
DDRA_MAA[12..0] 10,13
DDRA_DQS[8..0] 10,13
DDRA_MD[63..0] 10,13
DDRA_ECC[7..0] 10,13
VTT_DDRVTT_DDRVTT_DDR VTT_DDR
RN14
1
2
3
4
5
6
7
8
8P4R-56R
RN12
1
2
3
4
5
6
7
8
8P4R-56R
RN9
1
2
3
4
5
6
7
8
8P4R-56R
RN7
1
2
3
4
5
6
7
8
8P4R-56R
RN5
1
2
3
4
5
6
7
8
8P4R-56R
RN3
1
2
3
4
5
6
7
8
8P4R-56R
R87 56R
DDRB_CAS10,14
DDRB_WE10,14
DDRB_RAS10,14
DDRB_BANKB110,14
DDRB_CS110,14
DDRB_CS010,14
DDRB_CS310,14
DDRB_CS210,14
DDRB_CKE010,14
DDRB_CKE210,14
DDRB_CKE310,14
DDRB_CKE110,14
DDRB_BANKB010,14
DDRB_MAB[12..0]
DDRB_DQS[8..0]
DDRB_MD[63..0]
DDRB_ECC[7..0]
DDRB_CAS
DDRB_WE
DDRB_RAS
DDRB_BANKB1
DDRB_CS1
DDRB_CS0
DDRB_CS3
DDRB_CS2
DDRB_CKE0
DDRB_CKE2
DDRB_CKE3
DDRB_CKE1
DDRB_BANKB0
DDRB_MAB0
DDRB_MAB2
DDRB_MAB1
DDRB_MAB9
DDRB_MAB11
DDRB_MAB12
DDRB_MAB5
DDRB_MAB6
DDRB_MAB7
DDRB_MAB8
DDRB_MAB3
DDRB_MAB4
DDRB_MAB10
DDRB_MAB[12..0] 10,14
DDRB_DQS[8..0] 10,14
DDRB_MD[63..0] 10,14
DDRB_ECC[7..0] 10,14
RN18
1
3
5
7
8P4R-47R
RN17
1
3
5
7
8P4R-47R
RN48
1
3
5
7
8P4R-47R
R75 47R
RN32
1
3
5
7
8P4R-47R
RN45
1
3
5
7
8P4R-47R
RN43
1
3
5
7
8P4R-47R
R99 47R
R100 47R
R85 47R
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
VTT_DDR VTT_DDR VTT_DDR VTT_DDR
B B
C53 C0.1U50Y
C61 C0.1U50Y
C72 C0.1U50Y
C84 C0.1U50Y
C95 C0.1U50Y
C121 C0.1U50Y
C143 C0.1U50Y
C160 C0.1U50Y
C181 C0.1U50Y
C185 C0.1U50Y
C174 C0.1U50Y
C120 C0.1U50Y
C58 C0.1U50Y
C126 C0.1U50Y
C49 C0.1U50Y
C64 C0.1U50Y
C76 C0.1U50Y
C87 C0.1U50Y
C98 C0.1U50Y
C128 C0.1U50Y
C147 C0.1U50Y
C169 C0.1U50Y
C194 C0.1U50Y
C202 C0.1U50Y
C184 C0.1U50Y
C156 C0.1U50Y
C97 C0.1U50Y
C27 C0.1U50Y
C115 C0.1U50Y
C41 C0.1U50Y
C67 C0.1U50Y
C88 C0.1U50Y
C113 C0.1U50Y
C135 C0.1U50Y
C158 C0.1U50Y
C178 C0.1U50Y
C189 C0.1U50Y
C54 C0.1U50Y
C148 C0.1U50Y
C94 C0.1U50Y
C180 C0.1U50Y
C89 C0.1U50Y
C159 C0.1U50Y
C60 C0.1U50Y
C168 C0.1U50Y
C129 C0.1U50Y
C164 C0.1U50Y
C78 C0.1U50Y
VTT_DDR
C34 X_C10U6.3Y1206
C212 X_C10U6.3Y1206
C215 C10U6.3Y1206
C29 X_C10U6.3Y1206
C26 C10U6.3Y1206C201 C0.1U50Y
VDIMM
3VDU
U1
W83310DS_SOIC8
7
ENABLE
6
VCNTL
5
BOOT_SEL
C4
C1U16Y0805
DDR VTT Power
18
VINVREF2
2
GND
3
VREF1
4
VOUT
GND
9
+
EC1
X_CD1000U6.3EL15
VTT_DDR
+
EC2
CD470U10EL11.5
+
EC28
CD470U10EL11.5
C14
C0.1U50Y
VDIMM
R8
100R1%
R9
100R1%
A A
Title
MS-6758
Size Document Number Rev
DDR Terminator Resistor 20D
5
4
3
2
Date: Sheet
1
15 29Friday, February 13, 2004
of
Page 16

5
D D
PCI_AD0
PCI_AD1
PCI_AD2
PCI_AD3
PCI_AD4
PCI_AD5
PCI_AD6
PCI_AD7
PCI_AD8
PCI_AD9
PCI_AD10
PCI_AD11
PCI_AD12
PCI_AD13
PCI_AD14
PCI_AD15
PCI_AD16
PCI_AD17
PCI_AD18
PCI_AD19
PCI_AD20
PCI_AD21
PCI_AD22
PCI_AD23
PCI_AD24
PCI_AD25
C C
PCI_FRAME#6,19,20,21,22,23
PCI_IRDY#19,20,21,22,23
PCI_TRDY#19,20,21,22,23
PCI_DEVSEL#19,20,21,22,23
PCI_STOP#6,19,20,21,22,23
PCI_PERR#19,20,21,23
PCI_SERR#19,20,21
PCI_LOCK#19,20,21
PCI_PME#12,19,20,21
PCI_IRQ#A12,19,20,21
PCI_IRQ#B12,19,20,21
PCI_IRQ#C19,20,21
PCI_IRQ#D19,20,21
PCI_IRQ#E21
B B
PCI_IRQ#F21,23
PCI_IRQ#G21,22
PCI_IRQ#H21,22
PCI_REQ#119,21
PCI_REQ#220,21
PCI_REQ#320,21
PCI_REQ#421
SATA_REQ#21,22
PCI_GNT#119
PCI_GNT#220
PCI_GNT#320
PCI_GNT#421
SATA_GNT#22
VCC
PCI_REQ#56
PCI_GNT#56
SB_PCLK336
PCI_RST#9,27
A A
PCI_AD26
PCI_AD27
PCI_AD28
PCI_AD29
PCI_AD30
PCI_AD31
PCI_CBE#0
PCI_CBE#1
PCI_CBE#2
PCI_CBE#3
PCI_FRAME#
PCI_IRDY#
PCI_TRDY#
PCI_DEVSEL#
PCI_STOP#
PCI_PAR
PCI_PAR19,20,21,22,23
PCI_PERR#
PCI_SERR#
PCI_LOCK#
PCI_PME#
PCI_IRQ#A
PCI_IRQ#B
PCI_IRQ#C
PCI_IRQ#D
PCI_IRQ#E
PCI_IRQ#F
PCI_IRQ#G
PCI_IRQ#H
PCI_REQ#1
PCI_REQ#2
PCI_REQ#3
PCI_REQ#4
SATA_REQ#
PCI_GNT#1
PCI_GNT#2
PCI_GNT#3
PCI_GNT#4
SATA_GNT#
R319 2.7KR
PCI_REQ#5
R483 X_10KR
PCI_GNT#5
SB_PCLK33
R337 10R
U18A
J4
AD0
J5
AD1
G3
AD2
K4
AD3
H5
AD4
H2
AD5
J3
AD6
J2
AD7
K5
AD8
F2
AD9
M4
AD10
H4
AD11
L5
AD12
G2
AD13
K1
AD14
G5
AD15
G4
AD16
L1
AD17
B2
AD18
P5
AD19
H3
AD20
N5
AD21
C4
AD22
N4
AD23
E6
AD24
P3
AD25
D3
AD26
N2
AD27
F5
AD28
P4
AD29
F4
AD30
P2
AD31
E3
C/BE0#
J1
C/BE1#
N3
C/BE2#
M2
C/BE3#
D2
FRAME#
M3
IRDY#
E4
TRDY#
L3
DEVSEL#
E5
STOP#
F1
PAR
K2
PERR#
L4
SERR#
L2
PLOCK#
V2
PME#
B3
PIRQA#
E1
PIRQB#
A2
PIRQC#
C2
PIRQD#
D7
PIRQE#/GPI2
A6
PIRQF#/GPI3
E2
PIRQG#/GPI4
B1
PIRQH#/GPI5
D5
REQ0#
C1
REQ1#
C5
REQ2#
B6
REQ3#
C6
REQ4#/GPI40
D4
GNT0#
A3
GNT1#
B7
GNT2#
C7
GNT3#
A4
GNT4#/GPO48
A5
REQA#/GPI0
E7
REQB#REQ5#/GPI1
E8
GNTA#/GPO16
B4
GNTB#/GNT5#/GPO17
N1
PCICLK
V4
PCIRST#
INTEL-FW82801ER-A3
{Priority}
B5F6G1H6K6L6M10
G19
G21
VCC3_3
VCC3_3
VCC3_3
VCC3_3
VCC3_3
VCC3_3
VCC3_3
GND
GND
A1A7A10
N10P6R13
VCC3_3
VCC3_3
GND
GND
A15
A17
VCC3_3
VCC3_3
GND
GND
A19
A21
V19
W15
VCC3_3
VCC3_3
GND
GND
A23
AA5
VCC3_3
GND
W17
W24
VCC3_3
GND
AA7
AA9
AD13
AD20
VCC3_3
VCC3_3
GND
GND
AA11
AA13
K10
VCC3_3
GND
GND
AA21
AA24
4
K12
VCC1_5
VCC1_5
GND
GND
AB5
K13
L19
VCC1_5
GND
AB7
AB9
P19
R10R6H24
VCC1_5
VCC1_5
GND
GND
AB11
AB15
VCC1_5
VCC1_5
GND
GND
AB18
AC2
J19
VCC1_5
VCC1_5
GND
GND
AC4
K19
M15
VCC1_5
GND
AC6
AC8
N15
N23
VCC1_5
VCC1_5
GND
GND
AC10
AC13
E15
F15
VCC1_5
VCC1_5
GND
GND
AC23
AD4
F14
W19
VCC1_5
VCC1_5
GND
GND
AD6
AD8
R12W9W10
VCC1_5
VCC1_5
GND
GND
AD17
AD21
W11W6W7W8E22
VCC1_5
VCC1_5
VCC1_5
GND
GND
GND
AD12
B13
VCC1_5
GND
B17
VCC1_5
VCC1_5
GND
GND
B19
B21
VCC1_5
GND
B23C3C8
B15
E13
VCCSUS3_3
VCCSUS3_3
GND
GND
GND
C16
E14
E18
F16
F17
VCCSUS3_3
VCCSUS3_3
VCCSUS3_3
GND
GND
GND
C18
C20
C22D1D6
F18
K15U6V6
VCCSUS3_3
VCCSUS3_3
VCCSUS3_3
VCCSUS3_3
GND
GND
GND
GND
D11
D16
3
1.5VSB1
F19Y5AA4
VCCSUS3_3
VCCSUS1_5A
GND
GND
GND
D18
D20
D22
D24
1.5VSB2
1.5VSB3VCC1.5VCC3
AB4F7F8
VCCSUS1_5B
VCCSUS1_5B
VCCSUS1_5B
GND
GND
GND
GND
GND
E17
E19
E20
E21
3VDU3VDU
E11
VCCLAN3_3/VCCSUS3_3
VCCLAN1_5/VCCSUS1_5C
VCCLAN1_5/VCCSUS1_5C
GND
GND
GND
E23F3F9
F10
F11
VCCLAN3_3/VCCSUS3_3
VCCLAN3_3/VCCSUS3_3
PDCS1#
PDCS3#
PDIOR#
PDIOW#
PIORDY
PDDREQ
PDDACK#
SDCS1#
SDCS3#
SDIOR#
SDIOW#
SIORDY
SDDREQ
SDDACK#
AC_SDIN0
AC_SDIN1
AC_SDIN2
AC_SDOUT
AC_SYNC
AC_BIT_CLK
AC_RST#
PDD0
PDD1
PDD2
PDD3
PDD4
PDD5
PDD6
PDD7
PDD8
PDD9
PDD10
PDD11
PDD12
PDD13
PDD14
PDD15
PDA0
PDA1
PDA2
IRQ14
SDD0
SDD1
SDD2
SDD3
SDD4
SDD5
SDD6
SDD7
SDD8
SDD9
SDD10
SDD11
SDD12
SDD13
SDD14
SDD15
SDA0
SDA1
SDA2
IRQ15
AB16
Y13
Y14
AC14
AA14
AC15
AD14
AB14
AD15
Y15
AD16
AA15
AC16
Y16
AA16
AB17
AA19
AD19
AC19
AB19
Y18
AD18
AA17
AA18
AC17
AC18
Y17
AA22
AB23
AD23
AD24
AB21
AC21
AB20
AC20
Y19
AD22
AC22
AA20
AB22
AC24
AB24
AA23
W22
W23
W21
V22
V20
Y23
Y22
Y21
Y20
W20
Y24
E12
D12
A13
A9
B8
D8
C12
IDE_PD0
IDE_PD1
IDE_PD2
IDE_PD3
IDE_PD4
IDE_PD5
IDE_PD6
IDE_PD7
IDE_PD8
IDE_PD9
IDE_PD10
IDE_PD11
IDE_PD12
IDE_PD13
IDE_PD14
IDE_PD15
IDE_PDA0
IDE_PDA1
IDE_PDA2
IDE_PCS#1
IDE_PCS#3
IDE_PIOR#
IDE_PIOW#
IDE_PIORDY
IDE_PREQ
IDE_PACK#
IDE_IRQ14
IDE_SD0
IDE_SD1
IDE_SD2
IDE_SD3
IDE_SD4
IDE_SD5
IDE_SD6
IDE_SD7
IDE_SD8
IDE_SD9
IDE_SD10
IDE_SD11
IDE_SD12
IDE_SD13
IDE_SD14
IDE_SD15
IDE_SDA0
IDE_SDA1
IDE_SDA2
IDE_SCS#1
IDE_SCS#3
IDE_SIOR#
IDE_SIOW#
IDE_SIORDY
IDE_SREQ
IDE_SACK#
IDE_IRQ15
AC_SDATAIN
R299 22R
R311 22R
AC_BCLK
2
IDE_PDA0 21
IDE_PDA1 21
IDE_PDA2 21
IDE_PCS#1 21
IDE_PCS#3 21
IDE_PIOR# 21
IDE_PIOW# 21
IDE_PIORDY 21
IDE_PREQ 21
IDE_PACK# 21
IDE_IRQ14 21
IDE_SDA0 21
IDE_SDA1 21
IDE_SDA2 21
IDE_SCS#1 21
IDE_SCS#3 21
IDE_SIOR# 21
IDE_SIOW# 21
IDE_SIORDY 21
IDE_SREQ 21
IDE_SACK# 21
IDE_IRQ15 21
AC_SDATAIN 18
AC_SDATAOUT 18
AC_SYNC 18
AC_BCLK 18
AC_RST# 18
3VDU
VCC3
VCC1.5
VCC1.5
1.5VSB
3VDU
VCC3
ICH_SYNC9
CHIP_PWROK9,17,27
SB_PWROK9,17,27
PCI_CBE#[3..0]
PCI_AD[31..0]
IDE_SD[15..0]
IDE_PD[15..0]
C301
C1U16Y0805
C275
C1U16Y0805
C277
X_C4.7U10Y0805
CB24
C1U16Y
RN63
1
2
3
4
5
6
7
8
X_8P4R-0R
U14
X_LT1087S_SOT89
3 2
VIN VOUT1
C291
X_C1U10Y
1.5VSB1
1.5VSB3
1.5VSB2
VOUT2
ADJ/GND
1
CB21
C4.7U10Y0805
CB22
X_C1U16Y0805
C323
C1U16Y
1.5VSB1
1.5VSB2
1.5VSB2
1.5VSB3
4
PCI_CBE#[3..0] 19,20,21,22,23
PCI_AD[31..0] 19,20,21,22,23
IDE_SD[15..0] 21
IDE_PD[15..0] 21
CB23
C0.1U50Y
C289
X_C1U10Y
R1
R2
Vout= Vref*((R1+R2)/R1)* Iadj*R2
R328 X_1KR
R353
X_220R
Q34
X_N-MMBT3904_SOT23
ICH_SYNC
CHIP_PWROK
SB_PWROK
1
CB25
C4.7U10Y0805
C278
C1U16Y
C270
X_C1U10Y
C297 C0.01U50X
C327 C0.01U50X
C326 C0.01U50X
C320 C0.01U50X
EC30
X_C10U16EL
R266
X_470R1%
R269
X_100R1%
R326 X_220R
Q33
X_N-MMBT3904_SOT23
CP4
X_COPPER
R327 X_0R
CB26
C0.1U50Y
C274
X_C0.1U50Y
CB20
X_C1U16Y0805
C273
C1U16Y
1.5VSB
12
+
VCC3
Title
MS-6758
Size Document Number Rev
Intel ICH5 South Bridge_1 20D
5
4
3
2
Date: Sheet
1
16 29Friday, February 13, 2004
of
Page 17

5
RN92 X_8P4R-10KR
1
2
3
4
5
6
7
8
GND
E16
GND
H22J6J21
AD11
VCCRTC
V5REF_SUS
GND
GND
GND
GND
J23K3K11
R237 10KR
AA6
AB6
VCCSATAPLL
VCCSATAPLL
GND
GND
GND
GND
GND
GND
K14
K20
K22
K24
VCC3
D D
U18B
C10
C9
C11
D9
E9
B12
E10
R349 4.7KR
LDOUT
SB_USBP126
SB_USBN126
SB_USBP226
SB_USBN226
SB_USBP326
C C
SB_USBN326
SB_USBP426
SB_USBN426
SB_USBP526
SB_USBN526
SB_USBP626
SB_USBN626
SB_USBP726
SB_USBN726
SB_USBP826
SB_USBN826
USB_OC#126
USB_OC#326
USB_OC#526
USB_OC#726
SB_USBP1
SB_USBN1
SB_USBP2
SB_USBN2
SB_USBP3
SB_USBN3
SB_USBP4
SB_USBN4
SB_USBP5
SB_USBN5
SB_USBP6
SB_USBN6
SB_USBP7
SB_USBN7
SB_USBP8
SB_USBN8
USB_OC#1
USB_OC#3
USB_OC#5
USB_OC#7
R248 22.6R1%
VCC1.5
SB_USB48M
NB_HL0
NB_HL1
NB_HL2
NB_HL3
NB_HL4
NB_HL5
NB_HL6
NB_HL7
NB_HL8
NB_HL9
NB_HL10
R249 61.9R1%
NB_HLSTRF
NB_HLSTRS
R253 52.3R1%
NB_HLSWING
NB_HLVREF
SB_CLK66
SB_USB48M6
B B
NB_HLSTRF9
NB_HLSTRS9
NB_HLSWING9
NB_HLVREF9
SB_CLK666
A A
D10
AA1
B11
B9
B10
A12
C23
D23
A22
B22
C21
D21
A20
B20
C19
D19
A18
B18
C17
D17
A16
B16
C15
D15
D14
C14
B14
A14
D13
C13
A24
B24
F24
H20
H21
J20
H23
M23
M21
N21
M20
L22
J22
K21
G22
K23
J24
N24
L20
L24
N22
INTEL-FW82801ER-A3
{Priority}
LAN_RXD0
LAN_RXD1
LAN_RXD2
LAN_TXD0
LAN_TXD1
LAN_TXD2
LAN_CLK
LAN_RSTSYNC
LAN_RST#
EE_DIN
EE_DOUT
EE_CS
EE_SHCLK
USBP0P
USBP0N
USBP1P
USBP1N
USBP2P
USBP2N
USBP3P
USBP3N
USBP4P
USBP4N
USBP5P
USBP5N
USBP6P
USBP6N
USBP7P
USBP7N
OC0#
OC1#
OC2#
OC3#
OC4#/GPI9
OC5#/GPI10
OC6#/GPI14
OC7#/GPI15
USBRBIAS
USBRBIAS#
CLK48
HI0
HI1
HI2
HI3
HI4
HI5
HI6
HI7
HI8
HI9
HI10
HI11
HI_STBF
HI_STBS
HIRCOMP
HI_VSWING
HIREF
CLK66
A8
W14
V5REF
V5REF
GND
GND
GND
G6
G20
G24H1H19
VCOREVCC1.5VBAT5VSBV5REF
C24
R15
VCCUSBPLL
GND
GND
GND
L10
L11
L12
L13
4
R19
T19
A11R5U3Y2W4W5U21
NC
V_CPU_IO
V_CPU_IO
V_CPU_IO
GND
GND
GND
GND
GND
GND
L14
L15
L21
L23M1M5
GPI7
AGPBUSY#/GPI6
GND
GND
GND
GND
M11
M12
M13
M14
GPI8
GND
M22
GPI12
GND
GPI13
GND
M24
N11
T20
U22R1U20
SLP_S1#/GPO19
STP_PCI#/GPO18
GND
GND
GND
GND
N12
N13
N14
N20P1P10
F22
AC1W3V3W2T1
C3_STAT#/GPO21
CLKRUN#/GPIO24
STP_CPU#/GPO20
CPUPERF#/GPO22
SSMUXSEL/GPO23
GND
GND
GND
GND
GND
GND
GND
P11
P12
P13
P14
3
CSA_PME#
LPC_PME#
LAN_DIS#
SB_ATALED
AC7
AD7
AC9
AD9
AA8
AB8
AA10
AB10
Y11
Y9
AC5
AD5
T5
R4
R3
U4
T4
U5
R2
F23
AD2
AD1
AA2
AD3
V23
U24
R21
R23
U23
R22
NMI
V24
P22
T24
P23
T22
R24
P20
Y4
AC12
P24
R20
U1
AA12
AB13
W1
U2
AA3
AD10
Y12
V5
AC3
F20
AC11
AB12
AB3
RI#
E24
FWH_WP#
CPU_THERMTRIP#
SATA0_RXP
SATA0_RXN
SATA1_RXP
SATA1_RXN
SATA0_TXP
SATA0_TXN
SATA1_TXP
SATA1_TXN
R305 24.9R1%
SATA_CLK100
SATA_CLK100#
LPC_LAD0
LPC_LAD1
LPC_LAD2
LPC_LAD3
LPC_FRAME#
LPC_LDRQ#0
R330 X_8.2KR
SERIRQ#
R2351 200R
R2352 200R
SMLINK1
SMLINK0
CPU_A20M#
CPU_FERR#
CPU_IGNNE#
CPU_INIT#
CPU_LINT0
CPU_LINT1
CPU_SLP#
CPU_STPCLK#
KB_RST#
A20GATE
PWRBTIN#
SB_PWROK
CPU_PWRGD
VRM_PWRGD
R341 4.7KR
ICH_RST#
RTC_RST#
RSMRST#
SLP_S3#
SLP_S4#
R303 390KR
R302 X_390KR
R278 1MR
R332 10KR
R334 10KR
SB_14M
RTCX1
RTCX2
R348 10KR
SB_SPKR
R251 X_1KR
HIGH= No Reboot
R333 10KR
R345 4.7KR
G23
F21
AB1
AB2Y1T2
T21
SATA0RXP
SATA0RXN
SATA1RXP
GPIO25
GPIO27
GPIO28
GPIO32
GPIO33
GPIO34
BATLOW#
SUS_STAT#
SUSCLK
THRM#
SATA1RXN
THRMTRIP#
SATA0TXP
SATA0TXN
SATA1TXP
SATA1TXN
SATARBIASP
SATARBIASN
CLK100P
CLK100N
LFRAME#
LDRQ0#
LRDQ1#/GPI41
SERIRQ
SMBCLK
SMBDATA
SMLINK1
SMLINK0
IGNNE#
LAD0
LAD1
LAD2
LAD3
A20M#
FERR#
INIT#
INTR
SMI#
CPU_SLP#
STPCLK#
RCIN#
A20GATE
DPSLP#
DPRSLPVR
PWRBTN#
PWROK
CPUPWRGD/GPO49
VGATE/VRMPWRGD
SYS_RESET#
RTCRST#
RSMRST#
SLP_S3#
SLP_S4#
SLP_S5#
INTERVEN
INTRUDER#
LINKALERT#
SMBALERT#/GPI11
CLK14
RTCX1
RTCX2
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
P15
P21
R11
R14
T23T3T6
U19V1V21
W16
W18Y3Y6Y7Y8
GND
SPKR
GND
Y10
CSA_PME# 24
LPC_PME# 25
LAN_DIS# 24
SB_ATALED 28
FWH_WP# 28
3VDU
VCC3
CPU_THERMTRIP# 7
SATA_CLK100 6
SATA_CLK100# 6
LPC_LAD0 6,25,28
LPC_LAD1 6,25,28
LPC_LAD2 6,25
LPC_LAD3 6,25
LPC_FRAME# 6,25,28
LPC_LDRQ#0 25
VCC3
SERIRQ# 25
SMBCLK
SMBDATA
CPU_A20M# 7
CPU_FERR# 7
CPU_IGNNE# 7
CPU_INIT# 7,28
CPU_LINT0 7
CPU_LINT1 7
CPU_SMI# 7
CPU_SLP# 7
CPU_STPCLK# 7
KB_RST# 25
A20GATE 25
PWRBTIN# 25
SB_PWROK 9,16,27
CPU_PWRGD 7
VRM_PWRGD 5,6,28
3VDU
ICH_RST# 6,28
RSMRST# 24,27
SLP_S3# 25,27
SLP_S4# 27
VBAT
VBAT
3VDU
3VDU
SB_14M 6
3VDU
SB_SPKR 28
VCC3
2
VBAT_SIO
SMBCLK 6,13,14,21,25,27
SMBDATA 6,13,14,21,25,27
RTCX1
Y4
32.768KHZ12.5P_D
RTCX2
CPU_FERR#
CPU_THERMTRIP#
PWRBTIN#
5VSB
VCORE
R216 1KR
D19
S-1N5817_DO214AC
BAT1
BAT-2P_SO41
C312 C0.1U50Y
C318 C0.1U50Y
Closed to Pin
LAN_DIS#
R2337 20KR
1 2
R243 62R
R2356 4.7KR
C2294 X_C0.1U50Y
VRM_PWRGD
R235 1KR
R236 220R
Q31
N-MMBT3904_SOT23
SATA0_RXP
SATA0_RXN
SATA0_TXN
SATA0_TXP
CONN-SATA_white
R479
1KR
12
JBAT1(1-2)
JUMPER-1X2A_green
C315 C18P50N
4
R286
3
10MR
C313 C18P50N
C0.1U50Y
3VDU
Q30
N-MMBT3904_SOT23
SER1
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
3VDU
VBAT
2
3
D9
S-BAT54C_SOT23
1
R238 22KR
C251
_C1U10X/20%
VJBAT
C446
_C1U10X/20%
5VSB
V5REF
CSA_PME#
SMBCLK
SMBDATA
SMLINK1
SMLINK0
R2336 10KR
RN93
7
5
3
1
8P4R-2.7KR
NB_HLSWING
NB_HLVREF
C282 C0.01U50X
C280 C0.01U50X
Closed to Pin
VCORE
SB_PWROK
LDOUT
NB_HL[10..0]
VCC3 VCC
V5REF
R287 10KRR255 62R
Prevent excessive IccRTC leakage
R304 X_10KRC284
V5REF
D12
S-1N5817_DO214AC
SATA1_RXP
SATA1_RXN
SATA1_TXN
SATA1_TXP
1
VJBAT
RTC_RST#
R244 4.7KR
BAT_X1
BAT
BAT-BCR2032P
8
6
4
2
NB_HL[10..0] 9
R276 1KR
C305 C1U16Y
6
5
3
2
CONN-SATA_white
VCC3
3VDU
SER2
7
6
6
5
5
4
3
3
2
2
1
JBAT1
1
2
3
H1X3_black
3VDU
7
4
1
7
4
1
Title
MS-6758
Size Document Number Rev
Intel ICH5 South Bridge_2 20D
5
4
3
2
Date: Sheet
1
17 29Friday, February 13, 2004
of
Page 18

5
4
3
2
1
LINEIN_RC
LINEIN_LC
R380 4.7KR
R381 4.7KR
J9F
VCC
20
SPDIF_OUT
19
21
GND
22
GND
24
_CONN-AUDIOJACKX5_SPDIFX1
12
C206
X__C1200P50X
LINE_NEXT_R
LINE_NEXT_L
12
C209
X__C1200P50X
12
C205
X__C1200P50X
C399
X__C1200P50X
12
C210
X__C1200P50X
SR_OUTR
SR_OUTL
C424
X__C1200P50X
R179
X_22KR
R152
X_22KR
J9A
1
2
4
5
3
_CONN-AUDIOJACKX5_SPDIFX1
J9B
6
7
8
9
17
_CONN-AUDIOJACKX5_SPDIFX1
J9C
10
11
12
13
18
_CONN-AUDIOJACKX5_SPDIFX1
J9D
29
30
31
32
33
_CONN-AUDIOJACKX5_SPDIFX1
MIC_IN
LINE_OUT
LINE_IN
SR_OUT
14
15
16
C443
C1U16Y
VREFOUT
MIC_2
MIC_1
C368
X_C1U50Y
+5VR
SPDIF_OUT
C398
C0.1U50Y
C394 C1U16Y0805
C393 C1U16Y0805
D D
AC97_14M6
AC_RST#16
AC_SDATAIN16
AC_SDATAOUT16
AC_SYNC16
AC_BCLK16
C C
AUDIO_L21
AUDIO_R21
+5VR
R440
4.7KR
R441
4.7KR
B B
AC_XIN
LINEIN_LC
LINEIN_RC
AUDIO_L
AUDIO_R
CDGNDX
CDRX
MIC_1
MIC_2
C423
C1U16Y
SPDIF_OUT
C396
C1000P50X
R407 22R
R410 22R
C370
C10P50N
FR_MIC
R439 X_0R
C395 C1U16Y0805
VCC3
C0.1U50YC374
21
X_C0.1U50YC365
21
C362
X_C10P50N
C362=not
stuff
C2254 C1U16Y0805
C2255 C1U16Y0805
C2256 C1U16Y0805
C2257 C1U16Y0805
C354 C1U16Y0805
C348 C1U16Y0805
C353 C1U16Y0805
C352 C1U16Y0805
C351 C1U16Y0805
JAUD1
1 2
SPEAK_R
SPEAK_L
Short pin 5 & 6 ,
Short pin 9 & 10.
3 4
5
7
H2X5(8)_black
4847464544424140394338
U24
NC
1
9
4
7
2
3
11
8
5
10
6
12
NC
DVDD1
TEST6
DVDD2
DVSS1
DVSS2
XTL_IN
XTL_OUT
RESET#
SDATA_IN
SDATA_OUT
SYNC
BIT_CLK
PC_BEEP
6
109
TEST5
ALC
655/658
PHONE
AUXL
AUXR
1314151617181920212223
LINE_NEXT_R
LINE_NEXT_L
TEST4
TEST1
VIDEOL
VIDEOR
AVSS2
CDL
C411
TEST2
DACOUTL
DACOUTR
CDGND
CDR
+5VR
C0.1U50Y
MIC1
37
MONO
AVDD2
MIC2
+5VR
LOUTR
LOUTL
NC
NC
VRDA
VRAD
AFILT2
AFILT1
NC
VREF
AVDD1
AVSS1
LINL
LINR
24
ALC850
SPDIF_OUT
C433 C1U16Y0805
C434 C1U16Y0805
LINE_OUTR
36
LINE_OUTL
35
C367 C1U16Y0805
34
33
32
31
30
29
VREFOUT
28
27
25
26
R90
X_200R1%
EC43 C10U16EL
EC41 C10U16EL
+
+5VR
C355
C0.1U50Y
C349 X_C1U16Y0805
C350 X_C1U16Y0805
C110 C0.01U50X
EC38
C10U16EL
LEFT_OUT
CENT_OUT
SR_OUTR
SR_OUTL
+
+
C357
C1U16Y
C111
C560P50N
SPEAK_R
SPEAK_L
FR_MIC
C360
C1U16Y
C359
C1000P50X
LINEIN_RCCDLX
LINEIN_LC
JUSB1B
9
SPDIF OUT
10
CONN-RCA_USBX2
C364
C1000P50X
AUDIO CODEC REGULATORS
+12VR+12V
R428
3.3R1206
12
C415
C0.1U50Y
A A
5
3 1
12
C416
C0.1U50Y
VR1
MC78L05ACP_TO92
VIN VOUT
2
GND
+5VR
12
L11
X_60L1_100_1206
C412
C1U16Y0805
VCC
JAUD1(9-10)1
JUMPER-1X2A_green
JAUD1(5-6)1
JUMPER-1X2A_green
4
SPEAK_R
SPEAK_L
LINE_NEXT_R
LINE_NEXT_L
For EMI Only
C391 X_C1000P50X
C385 X_C1000P50X
C203 X_C1000P50X
C204 X_C1000P50X
3
CDRX
CDGNDX
CDLX
JCD1
AUDIO-CDIN1X4
2
LEFT_OUT
4
3
2
1
CENT_OUT
R154
R153
X_22KR
X_22KR
Title
Size Document Number Rev
Date: Sheet
J9E
25
26
27
28
23
_CONN-AUDIOJACKX5_SPDIFX1
C/W_OUT
MS-6758
RealTek ALC655/658 AC97 Codec 20D
1
18 29Friday, February 13, 2004
of
Page 19

5
4
3
2
1
PCI1
-12V
PCI_TCK
PCI_TCK20
D D
C C
B B
VCC
VCC
PCI_IRQ#B12,16,20,21 PCI_IRQ#C 16,20,21
PCI_IRQ#D16,20,21
PCI_PCLK16
PCI_REQ#06
PCI_IRDY#16,20,21,22,23
PCI_DEVSEL#16,20,21,22,23
PCI_LOCK#16,20,21
PCI_PERR#16,20,21,23
PCI_SERR#16,20,21
PCI_IRQ#B
PCI_IRQ#D
PCI_PCLK1
PCI_REQ#0
VCC
PCI_AD31
PCI_AD29
PCI_AD27
PCI_AD25
VCC3
PCI_CBE#3
PCI_AD23
PCI_AD21
PCI_AD19
VCC3
PCI_AD17 PCI_AD16
PCI_CBE#2
PCI_IRDY#
VCC3
PCI_DEVSEL#
PCI_LOCK#
PCI_PERR#
VCC3
PCI_SERR#
VCC3
PCI_CBE#1
PCI_AD14
PCI_AD12
PCI_AD10
PCI_AD7
VCC3
PCI_AD5
PCI_AD3
VCC
ACK641#
VCC
VCC
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B52
B53
B54
B55
B56
B57
B58
B59
B60
B61
B62
-12V
TCK
GND
TDO
+5V
+5V
INTB#
INTD#
PRSNT#1
RESERVED
PRSNT#2
GND
GND
RESERVED
GND
CLK
GND
REQ#
+5V(I/O)
AD31
AD29
GND
AD27
AD25
+3.3V
C/BE#3
AD23
GND
AD21
AD19
+3.3V
AD17
C/BE#2
GND
IRDY#
+3.3V
DEVSEL#
GND
LOCK#
PERR#
+3.3V
SERR#
+3.3V
C/BE#1
AD14
GND
AD12
AD10
GND
AD8
AD7
+3.3V
AD5
AD3
GND
AD1
+5V(I/O)
ACK64#
+5V
+5V
SLOT-PCI
TRST#
+12V
TMS
INTA#
INTC#
RESERVED
+5V(I/O)
RESERVED
GND
GND
3.3VAUX
RST#
+5V(I/O)
GNT#
GND
PME#
AD30
+3.3V
AD28
AD26
GND
AD24
IDSEL
+3.3
AD22
AD20
GND
AD18
AD16
+3.3V
FRAME#
GND
TRDY#
GND
STOP#
+3.3V
SMBCLK
SMBDAT
GND
PAR
AD15
+3.3V
AD13
AD11
GND
AD9
C/BE#0
+3.3V
AD6
AD4
GND
AD2
AD0
+5V(I/O)
REQ64#
TDI
+5V
+5V
+5V
+5V
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32
A33
A34
A35
A36
A37
A38
A39
A40
A41
A42
A43
A44
A45
A46
A47
A48
A49
A52
A53
A54
A55
A56
A57
A58
A59
A60
A61
A62
PCI_TRST#
PCI_TMS
PCI_TDI
PCI_IRQ#A
PCI_IRQ#C
SLOT_RST#
PCI_GNT#0
PCI_PME#
PCI_AD30
PCI_AD28
PCI_AD26
PCI_AD24
R268 100R
PCI_AD22
PCI_AD20
PCI_AD18
PCI_FRAME#
PCI_TRDY#
PCI_STOP#
SMBCLK_PCI
SMBDATA_PCI
PCI_PAR
PCI_AD15
PCI_AD13
PCI_AD11
PCI_AD9
PCI_CBE#0PCI_AD8
PCI_AD6
PCI_AD4
PCI_AD2
PCI_AD0PCI_AD1
REQ641#
PCI_TRST# 20
+12V
PCI_TMS 20
PCI_TDI 20
VCC
PCI_IRQ#A 12,16,20,21
VCC
VCC
3VDU
SLOT_RST# 12,20,21,27
VCC
PCI_GNT#0 6
PCI_PME# 12,16,20,21
VCC3
PCI_AD16
VCC3
VCC3
PCI_FRAME# 6,16,20,21,22,23
PCI_TRDY# 16,20,21,22,23
PCI_STOP# 6,16,20,21,22,23
VCC3
SMBCLK_PCI 20,21
SMBDATA_PCI 20,21
PCI_PAR 16,20,21,22,23
VCC3
VCC3
VCC
VCC
VCC
PCI_PME#
PCI_IRQ#C16,20,21 PCI_IRQ#D 16,20,21
PCI_IRQ#A12,16,20,21
PCI_PCLK26
PCI_REQ#116,21
VCC3
VCC3
VCC3
VCC3
VCC3
VCC3
C451 X__C1200P50X
1 2
-12V
PCI_TCK
VCC
VCC
PCI_IRQ#C
PCI_IRQ#A
PCI_PCLK2
PCI_REQ#1
VCC
PCI_AD31
PCI_AD29
PCI_AD27
PCI_AD25
PCI_CBE#3
PCI_AD23
PCI_AD21
PCI_AD19
PCI_AD17
PCI_CBE#2
PCI_IRDY#
PCI_DEVSEL#
PCI_LOCK#
PCI_PERR#
PCI_SERR#
PCI_CBE#1
PCI_AD14
PCI_AD12 PCI_AD11
PCI_AD10
PCI_AD8
PCI_AD7
PCI_AD5
PCI_AD3
PCI_AD1
VCC
ACK642# REQ642#
VCC
VCC
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B52
B53
B54
B55
B56
B57
B58
B59
B60
B61
B62
PCI2
-12V
TCK
GND
TDO
+5V
+5V
INTB#
INTD#
PRSNT#1
RESERVED
PRSNT#2
GND
GND
RESERVED
GND
CLK
GND
REQ#
+5V(I/O)
AD31
AD29
GND
AD27
AD25
+3.3V
C/BE#3
AD23
GND
AD21
AD19
+3.3V
AD17
C/BE#2
GND
IRDY#
+3.3V
DEVSEL#
GND
LOCK#
PERR#
+3.3V
SERR#
+3.3V
C/BE#1
AD14
GND
AD12
AD10
GND
AD8
AD7
+3.3V
AD5
AD3
GND
AD1
+5V(I/O)
ACK64#
+5V
+5V
SLOT-PCI
TRST#
+12V
INTA#
INTC#
RESERVED
+5V(I/O)
RESERVED
GND
GND
3.3VAUX
RST#
+5V(I/O)
GNT#
GND
PME#
AD30
+3.3V
AD28
AD26
GND
AD24
IDSEL
AD22
AD20
GND
AD18
AD16
+3.3V
FRAME#
GND
TRDY#
GND
STOP#
+3.3V
SMBCLK
SMBDAT
GND
AD15
+3.3V
AD13
AD11
GND
C/BE#0
+3.3V
GND
+5V(I/O)
REQ64#
TMS
+5V
+5V
+3.3
PAR
AD9
AD6
AD4
AD2
AD0
+5V
+5V
PCI_TRST#
A1
A2
PCI_TMS
A3
PCI_TDI
A4
TDI
A5
PCI_IRQ#B
A6
PCI_IRQ#D
A7
A8
A9
A10
A11
A12
A13
A14
SLOT_RST#
A15
A16
PCI_GNT#1
A17
A18
PCI_PME#
A19
PCI_AD30
A20
A21
PCI_AD28
A22
PCI_AD26
A23
A24
PCI_AD24
A25
R313 100R
A26
A27
PCI_AD22
A28
PCI_AD20
A29
A30
PCI_AD18
A31
PCI_AD16
A32
A33
PCI_FRAME#
A34
A35
PCI_TRDY#
A36
A37
PCI_STOP#
A38
A39
SMBCLK_PCI
A40
SMBDATA_PCI
A41
A42
PCI_PAR
A43
PCI_AD15
A44
A45
PCI_AD13
A46
A47
A48
PCI_AD9
A49
PCI_CBE#0
A52
A53
PCI_AD6
A54
PCI_AD4
A55
A56
PCI_AD2
A57
PCI_AD0
A58
A59
A60
A61
A62
+12V
VCC
PCI_IRQ#B 12,16,20,21
VCC
VCC
3VDU
VCC
PCI_GNT#1 16
VCC3
PCI_AD17
VCC3
VCC3
VCC3
VCC3
VCC3
VCC
VCC
VCC
PCI_CBE#[3..0]
PCI_AD[31..0]
PCI_TDI
PCI_TMS
PCI_TRST#
PCI_TCK
ACK641#
REQ641#
ACK642#
REQ642#
PCI_CBE#[3..0] 16,20,21,22,23
PCI_AD[31..0] 16,20,21,22,23
RN83
1
2
3
4
5
6
7
8
X_8P4R-5.6KR
RN65
1
2
3
4
5
6
7
8
VCC
VCC
VCC3
VCC
12
+
EC40
X_CD1000U6.3EL15
C378
X_C0.1U50Y
C400
C0.1U50Y
C372
C0.1U50Y
C319
C0.1U50Y
C77
C0.1U50Y
C383
C0.1U50Y
3VDU
+12V -12V
12
+
EC35
X_CD1000U6.3EL15
C380
C0.1U50Y
C382
C0.1U50Y
C379
C0.1U50Y
C198
C0.1U50Y
8P4R-2.7KR
A A
Title
MS-6758
Size Document Number Rev
PCI Slot_1 and Slot_2 20D
5
4
3
2
Date: Sheet
1
19 29Friday, February 13, 2004
of
Page 20

5
4
3
2
1
PCI3
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B52
B53
B54
B55
B56
B57
B58
B59
B60
B61
B62
B1
B2
B3
B4
B5
B6
B7
B8
B9
-12V
TCK
GND
TDO
+5V
+5V
INTB#
INTD#
PRSNT#1
RESERVED
PRSNT#2
GND
GND
RESERVED
GND
CLK
GND
REQ#
+5V(I/O)
AD31
AD29
GND
AD27
AD25
+3.3V
C/BE#3
AD23
GND
AD21
AD19
+3.3V
AD17
C/BE#2
GND
IRDY#
+3.3V
DEVSEL#
GND
LOCK#
PERR#
+3.3V
SERR#
+3.3V
C/BE#1
AD14
GND
AD12
AD10
GND
AD8
AD7
+3.3V
AD5
AD3
GND
AD1
+5V(I/O)
ACK64#
+5V
+5V
SLOT-PCI
TRST#
+12V
INTA#
INTC#
RESERVED
+5V(I/O)
RESERVED
GND
GND
3.3VAUX
RST#
+5V(I/O)
GNT#
GND
PME#
AD30
+3.3V
AD28
AD26
GND
AD24
IDSEL
AD22
AD20
GND
AD18
AD16
+3.3V
FRAME#
GND
TRDY#
GND
STOP#
+3.3V
SMBCLK
SMBDAT
GND
AD15
+3.3V
AD13
AD11
GND
C/BE#0
+3.3V
GND
+5V(I/O)
REQ64#
TMS
+3.3
PAR
AD9
AD6
AD4
AD2
AD0
TDI
+5V
+5V
+5V
+5V
-12V
PCI_TCK
D D
C C
B B
PCI_TCK19
VCC
VCC
PCI_IRQ#D16,19,21 PCI_IRQ#A 12,16,19,21 PCI_IRQ#B 12,16,19,21
PCI_IRQ#B12,16,19,21
PCI_PCLK36
PCI_REQ#216,21
PCI_IRDY#16,19,21,22,23
PCI_DEVSEL#16,19,21,22,23
PCI_LOCK#16,19,21
PCI_PERR#16,19,21,23
PCI_SERR#16,19,21
PCI_IRQ#D
PCI_IRQ#B
PCI_PCLK3
PCI_REQ#2
VCC
PCI_AD31
PCI_AD29
PCI_AD27
PCI_AD25
VCC3
PCI_CBE#3
PCI_AD23
PCI_AD21
PCI_AD19
VCC3
PCI_AD17
PCI_CBE#2
PCI_IRDY#
VCC3
PCI_DEVSEL#
PCI_LOCK#
PCI_PERR#
VCC3
PCI_SERR#
VCC3
PCI_CBE#1
PCI_AD14
PCI_AD12 PCI_AD11
PCI_AD10
PCI_AD8
PCI_AD7
VCC3
PCI_AD5
PCI_AD3
PCI_AD1
VCC
ACK643# REQ643#
VCC
VCC
PCI_TRST#
A1
A2
PCI_TMS
A3
PCI_TDI
A4
A5
PCI_IRQ#C
A6
PCI_IRQ#A
A7
A8
A9
A10
A11
A12
A13
A14
SLOT_RST#
A15
A16
PCI_GNT#2
A17
A18
PCI_PME#
A19
PCI_AD30
A20
A21
PCI_AD28
A22
PCI_AD26
A23
A24
PCI_AD24
A25
R329 100R R404 100R
A26
A27
PCI_AD22
A28
PCI_AD20
A29
A30
PCI_AD18
A31
PCI_AD16
A32
A33
PCI_FRAME#
A34
A35
PCI_TRDY#
A36
A37
PCI_STOP#
A38
A39
SMBCLK_PCI
A40
SMBDATA_PCI
A41
A42
PCI_PAR
A43
PCI_AD15
A44
A45
PCI_AD13
A46
A47
A48
PCI_AD9
A49
PCI_CBE#0
A52
A53
PCI_AD6
A54
PCI_AD4
A55
A56
PCI_AD2
A57
PCI_AD0
A58
A59
A60
A61
A62
PCI_TRST# 19
+12V
PCI_TMS 19
PCI_TDI 19
VCC
PCI_IRQ#C 16,19,21
VCC
VCC
3VDU
SLOT_RST# 12,19,21,27
VCC
PCI_GNT#2 16
PCI_PME# 12,16,19,21
VCC3
PCI_AD18
VCC3
VCC3
PCI_FRAME# 6,16,19,21,22,23
PCI_TRDY# 16,19,21,22,23
PCI_STOP# 6,16,19,21,22,23
VCC3
SMBCLK_PCI 19,21
SMBDATA_PCI 19,21
PCI_PAR 16,19,21,22,23
VCC3
C2293 X_C0.1U50Y
PCI_PME#
VCC3
VCC
VCC
VCC
-12V
PCI_TCK
VCC
VCC
VCC
VCC3
VCC3
VCC3
VCC3
VCC3
VCC3
PCI_IRQ#A
PCI_IRQ#C
PCI_PCLK4
PCI_REQ#3
PCI_AD31
PCI_AD29
PCI_AD27
PCI_AD25
PCI_CBE#3
PCI_AD23
PCI_AD21
PCI_AD19
PCI_AD17
PCI_CBE#2
PCI_IRDY#
PCI_DEVSEL#
PCI_LOCK#
PCI_PERR#
PCI_SERR#
PCI_CBE#1
PCI_AD14
PCI_AD12
PCI_AD10
PCI_AD8
PCI_AD7
PCI_AD5
PCI_AD3
PCI_IRQ#A12,16,19,21
PCI_IRQ#C16,19,21
PCI_PCLK46
PCI_REQ#316,21
PCI_AD1
ACK644#
VCC
VCC
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B52
B53
B54
B55
B56
B57
B58
B59
B60
B61
B62
PCI4
-12V
TCK
GND
TDO
+5V
+5V
INTB#
INTD#
PRSNT#1
RESERVED
PRSNT#2
GND
GND
RESERVED
GND
CLK
GND
REQ#
+5V(I/O)
AD31
AD29
GND
AD27
AD25
+3.3V
C/BE#3
AD23
GND
AD21
AD19
+3.3V
AD17
C/BE#2
GND
IRDY#
+3.3V
DEVSEL#
GND
LOCK#
PERR#
+3.3V
SERR#
+3.3V
C/BE#1
AD14
GND
AD12
AD10
GND
AD8
AD7
+3.3V
AD5
AD3
GND
AD1
+5V(I/O)
ACK64#
+5V
+5V
SLOT-PCI
TRST#
+12V
TMS
INTA#
INTC#
RESERVED
+5V(I/O)
RESERVED
GND
GND
3.3VAUX
RST#
+5V(I/O)
GNT#
GND
PME#
AD30
+3.3V
AD28
AD26
GND
AD24
IDSEL
+3.3
AD22
AD20
GND
AD18
AD16
+3.3V
FRAME#
GND
TRDY#
GND
STOP#
+3.3V
SMBCLK
SMBDAT
GND
PAR
AD15
+3.3V
AD13
AD11
GND
AD9
C/BE#0
+3.3V
AD6
AD4
GND
AD2
AD0
+5V(I/O)
REQ64#
PCI_TRST#
A1
A2
PCI_TMS
A3
PCI_TDI
A4
TDI
A5
+5V
+5V
+5V
+5V
PCI_IRQ#D
A6
PCI_IRQ#B
A7
A8
A9
A10
A11
A12
A13
A14
SLOT_RST#
A15
A16
PCI_GNT#3
A17
A18
PCI_PME#
A19
PCI_AD30
A20
A21
PCI_AD28
A22
PCI_AD26
A23
A24
PCI_AD24
A25
A26
A27
PCI_AD22
A28
PCI_AD20
A29
A30
PCI_AD18
A31
PCI_AD16
A32
A33
PCI_FRAME#
A34
A35
PCI_TRDY#
A36
A37
PCI_STOP#
A38
A39
SMBCLK_PCI
A40
SMBDATA_PCI
A41
A42
PCI_PAR
A43
PCI_AD15
A44
A45
PCI_AD13
A46
PCI_AD11
A47
A48
PCI_AD9
A49
PCI_CBE#0
A52
A53
PCI_AD6
A54
PCI_AD4
A55
A56
PCI_AD2
A57
PCI_AD0
A58
A59
REQ644#
A60
A61
A62
+12V
VCC
PCI_IRQ#D 16,19,21
VCC
VCC
3VDU
VCC
PCI_GNT#3 16
VCC3
PCI_AD19
VCC3
VCC3
VCC3
VCC3
VCC3
VCCVCC
VCC
VCC
PCI_CBE#[3..0]
PCI_AD[31..0]
ACK643#
REQ643#
ACK644#
REQ644#
A A
5
4
PCI_CBE#[3..0] 16,19,21,22,23
PCI_AD[31..0] 16,19,21,22,23
RN75
1
2
3
4
5
6
7
8
8P4R-2.7KR
VCC
VCC
VCC3
12
+
EC34
.CD1000U6.3EL15
3
C343
C0.1U50Y
C337
X_C0.1U50Y
C335
C0.1U50Y
C324
X_C0.1U50Y
VCC
C272
C0.1U50Y
C10
C0.1U50Y
3VDU
C336
C0.1U50Y
+12V -12V
C334
C0.1U50Y
2
C340
C0.1U50Y
C341
C0.1U50Y
Title
MS-6758
Size Document Number Rev
PCI Slot_3 and Slot_4 20D
Date: Sheet
1
20 29Friday, February 13, 2004
of
Page 21

5
D D
-12V
AUDIO_L18
AUDIO_R18
VCC
VCC
5VDUR
VCC
VCC3
VCC3
VCC3
VCC3
VCC3
VCC3
VCC
VCC
VCC
PCI5_REQ#
PCI_IRQ#C
PCI_IRQ#A
AUDIO_L
AUDIO_R
PCI5_CLK
PCI_PCLK5
PCI_REQ#4
PCI_AD31
PCI_AD29
PCI_AD27
PCI_AD25
PCI_CBE#3
PCI_AD23
PCI_AD21
PCI_AD19
PCI_AD17
PCI_CBE#2
PCI_IRDY#
PCI_DEVSEL#
PCI_LOCK#
PCI_PERR#
PCI_SERR#
PCI_CBE#1
PCI_AD14
PCI_AD12
PCI_AD10
PCI_AD8
PCI_AD7
PCI_AD5
PCI_AD3
PCI_AD1
ACK645#
PCI5_REQ#6
PCI_IRQ#C16,19,20 PCI_IRQ#D 16,19,20
PCI_IRQ#A12,16,19,20
PCI5_CLK6
PCI_PCLK56
PCI_REQ#416
C C
PCI_IRDY#16,19,20,22,23
PCI_DEVSEL#16,19,20,22,23
PCI_LOCK#16,19,20
PCI_PERR#16,19,20,23
PCI_SERR#16,19,20
B B
PCI5
B1
-12V
B2
TCK
B3
GND
B4
TDO
B5
+5V
B6
+5V
B7
INTB#
B8
INTD#
B9
PRSNT#1
B10
RESERVED
B11
PRSNT#2
B12
GND
B13
GND
B14
RESERVED
B15
GND
B16
CLK
B17
GND
B18
REQ#
B19
+5V(I/O)
B20
AD31
B21
AD29
B22
GND
B23
AD27
B24
AD25
B25
+3.3V
B26
C/BE#3
B27
AD23
B28
GND
B29
AD21
B30
AD19
B31
+3.3V
B32
AD17
B33
C/BE#2
B34
GND
B35
IRDY#
B36
+3.3V
B37
DEVSEL#
B38
GND
B39
LOCK#
B40
PERR#
B41
+3.3V
B42
SERR#
B43
+3.3V
B44
C/BE#1
B45
AD14
B46
GND
B47
AD12
B48
AD10
B49
GND
B52
AD8
B53
AD7
B54
+3.3V
B55
AD5
B56
AD3
B57
GND
B58
AD1
B59
+5V(I/O)
B60
ACK64#
B61
+5V
B62
+5V
SLOT-PCI_orange
PCI_CBE#[3..0]
PCI_AD[31..0]
TRST#
+12V
TMS
TDI
+5V
INTA#
INTC#
+5V
RESERVED
+5V(I/O)
RESERVED
GND
GND
3.3VAUX
RST#
+5V(I/O)
GNT#
GND
PME#
AD30
+3.3V
AD28
AD26
GND
AD24
IDSEL
+3.3
AD22
AD20
GND
AD18
AD16
+3.3V
FRAME#
GND
TRDY#
GND
STOP#
+3.3V
SMBCLK
SMBDAT
GND
PAR
AD15
+3.3V
AD13
AD11
GND
AD9
C/BE#0
+3.3V
AD6
AD4
GND
AD2
AD0
+5V(I/O)
REQ64#
+5V
+5V
PCI_CBE#[3..0] 16,19,20,22,23
PCI_AD[31..0] 16,19,20,22,23
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32
A33
A34
A35
A36
A37
A38
A39
A40
A41
A42
A43
A44
A45
A46
A47
A48
A49
A52
A53
A54
A55
A56
A57
A58
A59
A60
A61
A62
4
PCI5_GNT#
PCI_IRQ#B
PCI_IRQ#D
R2335 100R
SLOT_RST#
PCI_GNT#4
PCI_PME#
PCI_AD30
PCI_AD28
PCI_AD26
PCI_AD24
R418 100R
PCI_AD22
PCI_AD20
PCI_AD18
PCI_AD16
PCI_FRAME#
PCI_TRDY#
PCI_STOP#
SMBCLK
SMBDATA
PCI_PAR
PCI_AD15
PCI_AD13
PCI_AD11
PCI_AD9
PCI_CBE#0
PCI_AD6
PCI_AD4
PCI_AD2
PCI_AD0
REQ645#
+12V
PCI5_GNT# 6
5VDUR
VCC
PCI_IRQ#B 12,16,19,20
VCC
PCI_AD22
VCC
5VDUR
3VDU
SLOT_RST# 12,19,20,27
VCC
PCI_GNT#4 16
PCI_PME# 12,16,19,20
VCC3
PCI_AD21
VCC3
VCC3
PCI_FRAME# 6,16,19,20,22,23
PCI_TRDY# 16,19,20,22,23
PCI_STOP# 6,16,19,20,22,23
VCC3
SMBCLK 6,13,14,17,25,27
SMBDATA 6,13,14,17,25,27
PCI_PAR 16,19,20,22,23
VCC3
VCC3
VCC
VCC
VCC
VCC
VCC3
C2269
C0.1U50Y
VCC
VCC3
+12V
SMBDATA_PCI19,20
SATA_REQ#16,22
C295
C0.1U50Y
SMBCLK_PCI19,20
PCI_IRQ#A12,16,19,20
PCI_IRQ#C16,19,20
PCI_IRQ#D16,19,20
PCI_IRQ#B12,16,19,20
PCI_IRQ#G16,22
PCI_IRQ#H16,22
PCI_IRQ#E16
PCI_IRQ#F16,23
PCI_REQ#116,19
PCI_REQ#416
PCI_REQ#316,20
PCI_REQ#216,20
12
+
12
+
3
EC33
.CD1000U6.3EL15
EC32
X_CD1000U6.3EL15
-12V
3VDU
C303
C0.1U50Y
ACK645#
REQ645#
SMBCLK_PCI
SMBDATA_PCI
PCI_IRQ#A
PCI_IRQ#C
PCI_IRQ#D
PCI_IRQ#B
PCI_IRQ#G
PCI_IRQ#H
PCI_IRQ#E
PCI_IRQ#F
PCI_FRAME#
PCI_IRDY#
PCI_TRDY#
PCI_DEVSEL#
PCI_STOP#
PCI_LOCK#
PCI_SERR#
PCI_REQ#1
PCI_REQ#4
PCI_REQ#3
SATA_REQ#
PCI_REQ#2
PCI_PERR#
C428
C0.1U50Y
C293
C0.1U50Y
C307
C0.1U50Y
8P4R-2.7KR
8P4R-2.7KR
8P4R-2.7KR
1
3
5
7
8P4R-2.7KR
1
3
5
7
8P4R-2.7KR
1
3
5
7
8P4R-2.7KR
R270 2.7KR
R417 2.7KR
1
3
5
7
1
3
5
7
1
3
5
7
RN68
RN69
RN76
C296
C0.1U50Y
C286
C0.1U50Y
RN84
RN67
RN73
2
IDE1
IDE_RST#
R161 33R
IDE_PREQ16
IDE_PIOW#16
IDE_PIOR#16
IDE_PACK#16
IDE_IRQ1416
IDE_PDA116
IDE_PDA016
IDE_PCS#116
IDE_PLED#28
C107
X_C0.1U50Y
C332
X_C0.1U50Y
IDE_RST#27
IDE_PIORDY16
IDE_PD[15..0]
IDE_PLED#
C292
X_C0.1U50Y
2
VCC
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
VCC
IDE_PIORDY
IDE_IRQ14
IDE_PDET#
IDE_RST#
IDE_SREQ16
IDE_SIOW#16
IDE_SIOR#16
IDE_SIORDY16
IDE_SACK#16
IDE_IRQ1516
IDE_SDA116
IDE_SDA016
IDE_SCS#116
IDE_SLED#28
IDE_SD[15..0]
IDE_SLED#
IDE_SIORDY
IDE_IRQ15
IDE_SDET#
CONN-IDE(20)V_blue
1
IDE_PD7
IDE_PD6
IDE_PD5
IDE_PD4
IDE_PD3
IDE_PD2
IDE_PD1
IDE_PD0
IDE_PREQ
IDE_PIOW#
IDE_PIOR#
IDE_PIORDY
IDE_PACK#
IDE_IRQ14
IDE_PDA1
IDE_PDA0
IDE_PCS#1 IDE_PCS#3
IDE_PLED#
R485 4.7KR
R263 4.7KR
R259 8.2KR
R103 15KR1%
C130 C0.047U50X
3 4
5 6
7 8
91110
13 14
17 18
19
21
23
25
27
29
31
33
35
37
2
12
1615
22
24
26
28
30
32
34
36
38
4039
IDE_PD8
IDE_PD9
IDE_PD10
IDE_PD11
IDE_PD12
IDE_PD13
IDE_PD14
IDE_PD15
IDE_PDET#
IDE_PDA2
IDE_PD[15..0] 16
VCC
IDE Connector
IDE2
CONN-IDE(20)V_white
R160 33R
IDE_SD7
IDE_SD6
IDE_SD5
IDE_SD4
IDE_SD3
IDE_SD2
IDE_SD1
IDE_SD0
IDE_SREQ
IDE_SIOW#
IDE_SIOR#
IDE_SIORDY
IDE_SACK#
IDE_IRQ15
IDE_SDA1
IDE_SDA0
IDE_SCS#1
IDE_SLED#
1
3 4
5 6
7 8
91110
13 14
17 18
19
21
23
25
27
29
31
33
35
37
R486 4.7KR
R242 4.7KR
R241 8.2KR
R112 15KR1%
C149 C0.047U50X
2
12
1615
22
24
26
28
30
32
34
36
38
4039
IDE_SD8
IDE_SD9
IDE_SD10
IDE_SD11
IDE_SD12
IDE_SD13
IDE_SD14
IDE_SD15
IDE_SDET#
IDE_SDA2
IDE_SCS#3
IDE_SD[15..0] 16
VCC
IDE_PDET# 28
IDE_PDA2 16
IDE_PCS#3 16
IDE_SDET# 28
IDE_SDA2 16
IDE_SCS#3 16
1
A A
Title
MS-6758
Size Document Number Rev
PCI Slot_5 and IDE Connector 20D
5
4
3
2
Date: Sheet
1
21 29Friday, February 13, 2004
of
Page 22

5
4
3
2
1
VATA25
GND
VDD25
GND
P3R3R4
C3
VDD25
VDD25
VDD25
GND
GND
GND
J11K7K8K9K10
R9
VDD25
GND
CP8 X_COPPER
K15
D15
E5
E13
K13M5N5N6N7N9N12
VDD25
VDD25
VDD25
VDD25
VDD25
VDD25
VDD25
GND
GND
GND
GND
GND
GND
GND
K11L7L8L9L10
C14
E6E7E11
E12
N13
VDDA
VDDA
VDDA
VDDA
VDD25
VDDA
VDD25
VDD25
VDD25
VDD25
DD1/VALID
DD10/RBC0
DD11/RXD5
DD12/RXD7
DD13/RXD9
DD14/TXD0
DD15/TXD2
GNDA
B14
GNDA
A5B5A7
DIOW/STOP/TXD3
GNDA
GNDA
GNDA
DDACK/TBC1
DCS0/TXD8
DCS1/TXD9
GNDA_T
A12
DIOR/HDMARDY/HSTROBE/TXD4
DRDY/DDMARDY/DSTROBE/TBC0
GND
GND
GNDA
L11
A14
B12
C4C5C15
VDDA
VDDA
VDDA
VDDA_T
VDDA_T
VDDA_T
VDDA_T
VDDA_T
VDDA_T
DD0/TXD1
DD2/RXD8
DD3/RXD6
DD4/RBC1
DD5/RXD4
DD6/RXD2
DD7/RXD0
DD8/RXD1
DD9/RXD3
DDREQ
PA0/TXD6
DA1/TXD5
DA2/TXD7
INTRQ
DEVRST
CABDET
REFCLK
VREF
COMPP
RXP1
RXN1
RXCMB1
TXP1
TXN1
TXCMB1
RXP2
RXN2
RXCMB2
TXP2
TXN2
TXCMB2
VDDAO
GNDAO
REXT
TCLK
GPIO1
GPIO2
GNDA_T
GNDA_T
GNDA_T
A10
B10
XO
XI
GNDA_T
GNDA_T
B7A9B9
C7
C9
C10
C12
D9
D10
K2
H2
G2
E1
D1
C2
B2
B3
A1
B1
D2
E2
F2
G1
J2
K1
G3
N3
L1
L2
M2
P2
R2
N2
N1
P1
J3
F3
L3
H1
A3
T1
B13
A13
C13
A11
B11
C11
A6
B6
C6
B8
A8
C8
B16
A15
A17
A16
B15
U6
B17
B4
ATAIDE_D0
ATAIDE_D1
ATAIDE_D2
ATAIDE_D3
ATAIDE_D4
ATAIDE_D5
ATAIDE_D6
ATAIDE_D7
ATAIDE_D8
ATAIDE_D9
ATAIDE_D10
ATAIDE_D11
ATAIDE_D12
ATAIDE_D13
ATAIDE_D14
ATAIDE_D15
ATAIDE_REQ
ATAIDE_ACK
ATAIDE_IOR#
ATAIDE_IOW#
ATAIDE_RDY
ATAIDE_CS#0
ATAIDE_CS#1
ATAIDE_SA0
ATAIDE_SA1
ATAIDE_SA2
ATAIDE_IRQ
ATAIDE_RST#
ATAIDE_LID
R412 X_4.7KR1%
R420 X_4.7KR1%
R399 X_4.7KR1%
C402 X_C1000P50X
C403 X_C1000P50X
C373 X_C0.01U50X
C405 X_C0.01U50X
C404 X_C0.01U50X
C384 X_C0.01U50X
C409 X_C1000P50X
C408 X_C1000P50X
C387 X_C0.01U50X
C407 X_C0.01U50X
C406 X_C0.01U50X
C397 X_C0.01U50X
CP10 X_COPPER
C386 X_C0.1U50Y
PSATA_RXP1
PSATA_RXN1
PSATA_TXP1
PSATA_TXN1
PSATA_RXP2
PSATA_RXN2
PSATA_TXP2
PSATA_TXN2
R424 X_6.19KR1%
R394 X_4.7KR
VTGPO2
PCI_CBE#[3..0]
PCI_AD[31..0]
VCC3
VATA25L
VATA25
PCI_CBE#[3..0] 16,19,20,21,23
PCI_AD[31..0] 16,19,20,21,23
VCC
Y5
X_25MHZ20P_D
C401
X_C18P50N
ATAIDE_D11
ATAIDE_D3
ATAIDE_IOW#
ATAIDE_D7
ATAIDE_D8
ATAIDE_D6 CONIDE_D6
ATAIDE_IOR# CONIDE_IOR#
ATAIDE_D5
ATAIDE_D10 CONIDE_D10
ATAIDE_D4
ATAIDE_SA1
ATAIDE_REQ ATAIDE_RDY
ATAIDE_IRQ
R366 X_330R
ATAIDE_RST#
PSATA_RXP1
PSATA_RXN1
PSATA_TXN1
PSATA_TXP1
VATA25
C392
X_C18P50N
VCC3 VATA25L
D D
PCI_AD0
PCI_AD1
PCI_AD2
PCI_AD3
PCI_AD4
PCI_AD5
PCI_AD6
PCI_AD7
PCI_AD8
PCI_AD9
PCI_AD10
PCI_AD11
PCI_AD12
PCI_AD13
PCI_AD14
PCI_AD15
PCI_AD16
PCI_AD17
PCI_AD18
PCI_AD19
PCI_AD20
PCI_AD21
PCI_AD22
PCI_AD23
PCI_AD24
PCI_AD25
PCI_AD26
PCI_PAR16,19,20,21,23
VATA25
PCI_AD27
PCI_AD28
PCI_AD29
PCI_AD30
PCI_AD31
PCI_CBE#0
PCI_CBE#1
PCI_CBE#2
PCI_CBE#3
PCI_FRAME#
PCI_DEVSEL#
PCI_IRDY#
PCI_TRDY#
PCI_STOP#
PCI_PAR
R395 X_100R
SATA_REQ#
SATA_GNT#
PCI_IRQ#G
PCI_IRQ#H
DEV_RST#
SATA_PCLK33
CP9 X_COPPER
C346 X_C0.1U50Y
ATPGEN
TESTMODE
TEST0
TEST1
TEST2
TEST3 IDE_SATA
R411 X_4.7KR
C C
PCI_FRAME#6,16,19,20,21,23
PCI_DEVSEL#16,19,20,21,23
PCI_IRDY#16,19,20,21,23
PCI_TRDY#16,19,20,21,23
PCI_STOP#6,16,19,20,21,23
PCI_AD30
SATA_REQ#16,21
SATA_GNT#16
PCI_IRQ#G16,21
PCI_IRQ#H16,21
DEV_RST#23,27
SATA_PCLK336
B B
J16
J17
K17
K16
L16
L17
M17
M16
N17
P17
P16
R16
R17
T17
T16
U16
U13
T13
U12
T12
T11
U11
U10
T10
U8
T8
T7
U7
T6
U5
U4
T5
N16
U17
T14
U9
U14
R13
R12
T15
U15
R15
T9
R7
R6
U1
T2
U2
T4
U3
T3
F15
F17
F16
G17
J15
H15
H16
H17
G16
A4
E17
C16
C17
D16
D17
E16
X_VT6420
U25
D3E3H3
M3
R5R8R10
K3
AD0
AD1
VCC3
VCC3
VCC3
VCC3
VCC3
VCC3
AD2
AD3
AD4
AD5
AD6
AD7
AD8
AD9
AD10
AD11
AD12
AD13
AD14
AD15
AD16
AD17
AD18
AD19
AD20
AD21
AD22
AD23
AD24
AD25
AD26
AD27
AD28
AD29
AD30
AD31
C_BE0
C_BE1
C_BE2
C_BE3
FRAME
DEVSEL
IRDY
TRDY
STOP
PAR
IDSEL
PREQL
PGNTL
INTA
INTB
PCIRST
PCICLK
VDDP
GNDP
EECS
EESK
EEDI
EEDO
LFRAME
LAD3
LAD2
LAD1
LAD0
ATPGEN
TESTMODE
TEST0
TEST1
TEST2
TEST3
TEST4
GND
GND
GND
GND
GND
GND
GND
GND
C1F1J1M1R1A2M15G7G8G9G10
VCC3
GND
R11
VCC3
GND
R14
VCC3
GND
G11
P15
VCC3
GND
H7H8H9
N15
VCC3
GND
L15
VCC3
GND
VCC3
GND
G15
E15
VCC3
VCC3
GND
GND
H10
H11J7J8J9J10
RN80
1
2
3
4
5
6
7
8
X_8P4R-33R
RN78
1
2
3
4
5
6
7
8
X_8P4R-33R
RN79
1
2
3
4
5
6
7
8
X_8P4R-33R
R369 X_33R
R368 X_33R R371 X_33R
R372 X_33R
VCC3
SER3
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
X_CONN-SATA_white
CB29
X_C1U16Y0805
CONIDE_D11
CONIDE_D3
CONIDE_IOW#
CONIDE_D7
CONIDE_D8
CONIDE_D9ATAIDE_D9
CONIDE_D5
CONIDE_D4
CONIDE_SA1
CONIDE_IRQ
R367 X_2.2KR
R374 X_4.7KR
R375 X_10KR
PSATA_RXP2
PSATA_RXN2
PSATA_TXN2
PSATA_TXP2
C366
X_C0.1U50Y
7/28 Modified
CONIDE_D7
CONIDE_D6
CONIDE_D5
CONIDE_D4
CONIDE_D3
CONIDE_D2
CONIDE_D1
CONIDE_D0
CONIDE_REQ
CONIDE_IOW#
CONIDE_IOR#
CONIDE_RDY
CONIDE_ACK
CONIDE_IRQ
CONIDE_SA1
CONIDE_SA0
CONIDE_CS#0
VCC
C363
X_C0.1U50Y
PATA_IDE
R495 X_4.7KR
SER4
7
6
6
6
5
5
5
4
3
3
3
2
2
2
1
X_CONN-SATA_white
C358
X_C0.1U50Y
PATA_IDE28
ATAIDE_D12
ATAIDE_D2
ATAIDE_D1
ATAIDE_SA0
ATAIDE_SA2
ATAIDE_CS#0
ATAIDE_CS#1
ATAIDE_D0
ATAIDE_D15
ATAIDE_ACK
7
7
4
4
1
1
IDE_SATA28
VATA25L
1
3
5
7
1
3
5
7
1
3
5
7
R370 X_33R
IDE3X__
1
3 4
5 6
7 8
91110
13 14
17 18
19
21
23
25
27
29
31
33
35
37
CB30
X_C1U16Y0805
IDE_SATA
RN81
CONIDE_D12
2
CONIDE_D2
4
CONIDE_D13ATAIDE_D13
6
CONIDE_D1
8
X_8P4R-33R
RN77
CONIDE_SA0
2
CONIDE_SA2
4
CONIDE_CS#0
6
CONIDE_CS#1
8
X_8P4R-33R
RN82
CONIDE_D14ATAIDE_D14
2
CONIDE_D0
4
CONIDE_D15
6
8
X_8P4R-33R
CONIDE_ACK
CONIDE_RDYCONIDE_REQ
2
CONIDE_D8
CONIDE_D9
CONIDE_D10
CONIDE_D11
CONIDE_D12
12
CONIDE_D13
CONIDE_D14
1615
CONIDE_D15
22
24
26
28
30
32
ATAIDE_LID
34
CONIDE_SA2
36
CONIDE_CS#1
38
4039
RN85 X_8P4R-4.7KR
TEST0
1
TEST2
3
TEST1
5
TEST3
7
RN86 X_8P4R-4.7KR
VTGPO2
ATPGEN
TESTMODE
1
3
5
7
7/28 Modified
C369
X_C0.1U50Y
R499 X_4.7KR
2
4
6
8
2
4
6
8
C377
X_C0.1U50Y
VCC3
CB28
A A
5
4
3
X_C0.1U50Y
CB27
X_C4.7U10Y0805
C381
X_C0.1U50Y
C347
X_C0.1U50Y
Title
MS-6758
Size Document Number Rev
VIA VT6420 Serial ATA Controller 20D
2
Date: Sheet
1
22 29Friday, February 13, 2004
of
Page 23

5
D D
CP5
33
9
VDD6
VSS6
16
114
VSS7
26
VDDC1
VSS8
VSS9 VDDC2
34 35
X_COPPER
24
RAMVDD
GNDATX0
59
64
GNDARX0
VCC3 V33EE
102
113
125
8
20
PCI_AD31
PCI_AD30
PCI_AD29
PCI_AD28
PCI_AD27
PCI_AD26
PCI_AD25
PCI_AD24
PCI_AD23
PCI_AD22
PCI_AD21
PCI_AD20
PCI_AD19
PCI_AD18
PCI_AD17
PCI_AD16
PCI_AD15
PCI_AD14
C C
PCI_FRAME#6,16,19,20,21,22
PCI_IRDY#16,19,20,21,22
PCI_TRDY#16,19,20,21,22
PCI_STOP#6,16,19,20,21,22
PCI_DEVSEL#16,19,20,21,22
1394_REQ#6
1394_GNT#6
PCI_PERR#16,19,20,21
B B
PCI_IRQ#F16,21
1394_PCLK336
DEV_RST#22,27
PCI_AD13
PCI_AD12
PCI_AD11
PCI_AD10
PCI_AD9
PCI_AD8
PCI_AD7
PCI_AD6
PCI_AD5
PCI_AD4
PCI_AD3
PCI_AD2
PCI_AD1
PCI_AD0
PCI_CBE#3
PCI_CBE#2
PCI_CBE#1
PCI_CBE#0
PCI_PAR
PCI_PAR16,19,20,21,22
PCI_FRAME#
PCI_IRDY#
PCI_TRDY#
PCI_STOP#
PCI_AD25
PCI_DEVSEL#
1394_REQ#
1394_GNT#
PCI_PERR#
PCI_IRQ#F
1394_PCLK33
DEV_RST#
VCC3
R357 4.7KR
R314
100R
97
AD31
VDD1
VDD2
VDD3
VDD4
94
VSS1
103
VSS2
111
VSS3
121
VSS4
VDD5
VSS5
1
98
AD30
99
AD29
100
AD28
101
AD27
104
AD26
105
AD25
106
AD24
109
AD23
110
AD22
112
AD21
116
AD20
117
AD19
118
AD18
119
AD17
120
AD16
5
AD15
6
AD14
7
AD13
10
AD12
11
AD11
12
AD10
13
AD9
14
AD8
17
AD7
18
AD6
19
AD5
21
AD4
22
AD3
23
AD2
27
AD1
28
AD0
107
CBE3#
122
CBE2#
4
CBE1#
15
CBE0#
3
PAR
123
FRAME#
124
IRDY#
126
TRDY#
128
STOP#
108
IDSEL
127
DEVSEL#
96
REQ#
95
GNT#
2
PERR#
91
INTA#
93
PCICLK
92
PCIRST#
37
PME#
PCI_CBE#[3..0]
PCI_AD[31..0]
4
39
49
62
76
75
65
PVDD1
PVDD2
VDDATX0
VDDATX1
VDDARX0
VSSC1
RAMVSS
VSSC2
GNDATX2
GNDARX2
GNDATX1
GNDARX1
115
25
36
83
82
69
68
PCI_CBE#[3..0] 16,19,20,21,22
PCI_AD[31..0] 16,19,20,21,22
90
89
XTPBIAS0
VDDATX2
VDDARX2
VDDARX1
XTPBIAS1
XTPBIAS2
D6/CMCJMP
PHYRESET
CTL0/PC0JMP
CTL1/PC1JMP
D7/PC2JMP
LINKON/TSIJMP
LREQ/TSOJMP
SCL/EECK
SDA/EEDI
PGND2
PGND1
41
50
XTPA0P
XTPA0M
XTPB0P
XTPB0M
XTPA1P
XTPA1M
XTPB1P
XTPB1M
XTPA2P
XTPA2M
XTPB2P
XTPB2M
XCPS
XREXT
MODE0
MODE1
SCLK
LPS/CMC
EEDO
EECS
VT6306-CD
U19
D5
D4
D3
D2
D1
D0
NC
XI
XO
TPBIAS0
74
VTPAP0
73
VTPAN0
72
VTPBP0
71
VTPBN0
70
TPBIAS1
81
VTPAP1
80
VTPAN1
79
VTPBP1
78
VTPBN1
77
TPBIAS2
88
VTPAP2
87
VTPAN2
86
VTPBP2
85
VTPBN2
84
R310 11KR1%
R312 1KR1%
63
R275 6.34KR1%
66
C309 C47P50N
52
C325 C0.1U50Y
58
54
55
53
57
56
51
48
47
R324 2KR1%
46
45
44
43
42
40
38
67
32
31
30
29
60
61
R355
R354
4.7KR
4.7KR
R356 510R1%
R298 1MR
Y3
24.576MHZ16P_D
C310
C10P50N
CPWR
V33EE
VCC3
U21
AT24C01A-10SI-2.7
6
SCLK
5
SDA
7
WPA0A1
C302
C10P50N
VCC
GND
3
VTPAP0
VTPAN0
VTPBP0
VTPBN0
R282
R283
54.9R1%
R284
54.9R1%
54.9R1%
TPBIAS0
C299
C0.33U16Y
VTPAP1
VTPAN1
VTPBP1
VTPBN1
R296
R297
54.9R1%
R279
54.9R1%
54.9R1%
TPBIAS1
C306
C0.33U16Y
VTPAP2
VTPAN2
VTPBP2
VTPBN2
R473
R474
54.9R1%
R475
54.9R1%
54.9R1%
TPBIAS2
C440
C0.33U16Y
8
VCC3
1
2
3
A2
4
VCC3 V33EE
C52
C328
C330
C0.1U50Y
C0.1U50Y
X_C0.1U50Y
C331
C0.1U50Y
2
R285
54.9R1%
R274
4.99KR1%
C300 C270P50N
R280
54.9R1%
R272
4.99KR1%
C304 C270P50N
R476
54.9R1%
R477
4.99KR1%
C441 C270P50N
C329
C0.1U50Y
1
D6
A C
+12V CPWR
S-MBRS340_CASE403
D18
A C
+12V CPWR_F
S-MBRS340_CASE403
7/28 Modified
CPWR
C317
C0.1U50Y
C316
C0.1U50Y
F1
F-MINISMDM150/24
12
+
EC19
C47U16EL
F4
F-MINISMDM150/24
VTPAP2 VTPAN2
VTPBP2 VTPBN2
VTPAN0
VTPAP0
VTPBN0
VTPBP0
VTPAP1
VTPAN1
VTPBP1
VTPBN1
12
+
EC52
C47U16EL
I1394_1
BH2X5(2)USB_green
1 2
3 4
6
5
7 8
10
R472 1MR
C442 C1000P50X
J4
7
SHLD
1
GND
6
TPA-
5
TPA+
4
TPB-
3
TPB+
2
PWR
8
SHLD
1394-6Mhorizontal_black
N5G-06M0021-K06
N5G-06M0021-K06
Connect Pin error
5
4
3
2
1
6
J3
SHLD
TPA+
TPATPB+
TPB-
SHLD
C83
C0.1U50Y
C438
C0.1U50Y
CPWR_FCPWR_F
C80
X_C0.1U50Y
C439
X_C0.1U50Y
1394-4M_black
A A
Title
MS-6758
Size Document Number Rev
VIA VT6307 IEEE1394 Controller 20D
5
4
3
2
Date: Sheet
1
23 29Friday, February 13, 2004
of
Page 24

5
4
3
2
1
U2011A (82547EI-B0) CRITICAL
3VDU
VCC1.2L
C2190
C1000P50X
3VDU
VCC1.2L
VCC1.8L
12
+
NC_F12
NC_H12
CSWING
CVREF
EC2026
C10U16EL
NB_CSA0
NB_CSA1
NB_CSA2
NB_CSA3
VCC1.2L
EI_CLK666
R2196
49.9R1%
VCC3
3VDU
25MHZ20P_D
C2195
C22P50N
C2160
C0.01U50X
NB_CSA4
NB_CSA5
NB_CSA6
NB_CSA7
NB_CSA8
NB_CSA9
NB_CSA10
NB_CSASTRS
NB_CSASTRF
R2267 30.1R1%
EI_CLK66
CHIP_RST#
CSA_PME#
R2240 3.3KR
R2266 3.3KR
R2213 1KR
Y2000
R2195
49.9R1%
3VDU
C2147
C0.1U50Y
3VDU
D D
NB_CSASTRS9
NB_CSASTRF9
CHIP_RST#6,25,27,28
CSA_PME#17
RSMRST#17,27
C C
EI_MDP0
EI_MDN0
EI_MDP1
EI_MDN1
EI_MDP2
EI_MDN2
EI_MDP3
EI_MDN3
B B
VCC1.8L
A A
EI_XTAL1
EI_XTAL2
C2194
C22P50N
R2194
49.9R1%
C2159
C0.01U50X
R2184 330R
EI_LINK_UP
EI_MDP0
EI_MDN0
EI_MDP1
EI_MDN1
EI_MDP2
EI_MDN2
EI_MDP3
EI_MDN3
R2181 330R
EI_100_UP
J1
CI[0]-NC
J2
CI[1]-NC
J3
CI[2]-NC
K1
CI[3]-NC
L3
CI[4]-NC
M2
CI[5]-NC
M1
CI[6]-NC
N2
CI[7]-NC
H3
CI[8]-NC
G2
CI[9]-NC
H1
CI[10]-NC
L1
CI_STRS-NC
L2
CI_STRF-NC
N3
CI_RCOMP-NC
G1
CI_CLK-NC
B9
PCI_RST#-NC
A2
INTA#-NC
A6
PME#-NC
B10
SMBALRT/PCI_PWR_GOOD-NC
A10
SMB_CLK-NC
C9
SMB_DAT-NC
A9
LAN_PWRGD-NC
J12
AUX_PWR-NC
K14
XTAL1-XTAL1
J14
XTAL2-XTAL2
M12
SDP[3]-LAN_RXD2
N13
SDP[2]-LAN_RXD1
P13
SDP[1]-LAN_RXD0
N14
SDP[0]-LAN_CLK
NB_CSA[10..0]
R2192
R2193
49.9R1%
49.9R1%
C2158
C0.01U50X
C2119
C0.1U50Y
EI_ACTLED
EI_1000
C2143
X_C0.1U50Y
R2191
49.9R1%
19
20
13
18
12
17
11
16
10
15
14
21
22
C2142
X_C0.1U50Y
CSA PortSDP/Jordan I/F
NB_CSA[10..0] 9
R2190
49.9R1%
C2157
C0.01U50X
LAN_USB2B
AMBER+
AMBER-
POWER
9
GREEN+
GREEN-
XX
TD1+
TD1TD2+
TD2TD3+
TD3TD4+
TD4-
GND
R2189
49.9R1%
LEDSEthernet PortEEPromSerial FLASHJTAG/LCI
EE_CS-NC
EE_SK-NC
EE_DI-NC
EE_DO-NC
EE_MODE
FLSH_SI-NC
C2197
C1U16Y
CTRL18
A12
C11
B11
B12
C13
C14
E13
E14
F13
F14
H13
H14
P7
M10
P10
N10
C4
M9
N9
M11
P9
L12
M13
L14
L13
M14
C2282
C0.1U50Y
LED_LINK_UP_N-LILED
LED_ACTIVITY_N-ACTLED
LED_LINK_100_N-SPEEDLED
LED_LINK_1000_N-TOUT
MDI_PLUS[0]-TDP
MDI_MINUS[0]-TDN
MDI_PLUS[1]-RDP
MDI_MINUS[1]-RDN
MDI_PLUS[2]-NC
MDI_MINUS[2]-NC
MDI_PLUS[3]-NC
MDI_MINUS[3]-NC
FLSH_CE_N-NC
FLSH_SCK-NC
FLSH_SO-NC
JTAG_TMS-NC
JTAG_TDI-LAN_RSTSYNC
JTAG_TCK-LAN_TXD2
JTAG_TRST#-LAN_TXD1
JTAG_TDO-LAN_TXD0
VCC
CSA crossed power plane
VCC1.2L
R2260
604R1%
R2261
665R1%
R2253
523R1%
EI_MDP0
EI_MDN0
EI_MDP1
EI_MDN1
EI_MDP2
EI_MDN2
EI_MDP3
EI_MDN3
EI_EECS
EI_EESK
EI_EEDI
EI_EEDO
LAN_DIS#
R2330 1KR
R2331 1KR
32
1
C2189
C4.7U10Y0805
CSWING
C2228
C0.1U50Y
CVREF
C2224
C0.1U50Y
R2218 330R
R2217 330R
U2013X_AT93C66
1
CS#
5
SI
2
SO
R2264 X_1KR
R2265 1KR
Microwire EEPROM
R255 For U13
R254 For U12
LAN_DIS# 17
EI_EECS
EI_EESK
EI_EEDI
EI_EEDO
3VDU
Q2035
P-BCP69_SOT223
4
VCC1.8L
C2283
C2284
C0.1U50Y
C0.1U50Y
C2242
C1U16Y
C2229
C1U16Y
EI_LINK_UP
EI_ACTLED
EI_100_UP
EI_1000
VCC
HOLD#SCK
WP#
GND
U2012
1
CS
2
SK
3
DI
4
DO
_M33-93C4653
8
76
3
4
3VDU
R2249 X_3.3KR
R2248 X_3.3KR
ASF 2.0
SPI EEPROM
ASF 1.0
8
VCC
7
NC
6
NC
5
GND
NC_F12
12
+
EC2027
C10U16EL
NC_H12
12
+
EC2028
C10U16EL
C2198
C0.1U50Y
C2191
C1000P50X
C2193
C1000P50X
U2011B (82547EI-B0) CRITICAL
G4
CSA_1.2V-NC_G4
H4
CSA_1.2V-NC_H4
J4
CSA_1.2V-NC_J4
M4
CSA_1.2V-NC_M4
J13
XTAL1.8V-NC
F12
CLKRCAP-NC_F12
H12
XTALCAP-NC_H12
B3
VSSPST-VSS_B3
B7
VSSPST-VSS_B7
C10
VSSPST-VSS_C10
E2
VSSPST-VSS_E2
M6
VSSPST-VSSA_M6
N12
VSSPST-VSSP_N12
P8
VSSPST-VSSA_P8
D5
VSS-VSS_D5
D7
VSS-VSS_D7
D8
VSS-VSS_D8
E5
VSS-VSS_E5
E6
VSS-VSS_E6
E7
VSS-VSS_E7
E8
VSS-VSS_E8
E9
VSS-VSS_E9
F4
VSS-VSSR_F4
F6
VSS-VSS_F6
F7
VSS-VSS_F7
F8
VSS-VSS_F8
F9
VSS-VSS_F9
F10
VSS-VSS_F10
G7
VSS-VSS_G7
G8
VSS-VSS_G8
G9
VSS-VSS_G9
G10
VSS-VSS_G10
G11
VSS-VSS_G11
H9
VSS-VSS_H9
H10
VSS-VSS_H10
L11
VSS-VSSP_L11
C12
ANALOG_VSS-VSSA_C12
D13
ANALOG_VSS-VSSA_D13
K12
ANALOG_VSS-VSSP_K12
G14
ANALOG_VSS-VSS_G14
F11
GNDC-VSS_F11
H2
CSA_VSS-NC_H2
M3
CSA_VSS-NC_M3
K2
CSA_VSS-VSS_K2
N1
CSA_VSS-VSS_N1
P3
CI_SWING-NC
N4
CI_VREF-NC
M5
PLL1.8V-NC
N5
PLLCAP-NC
L6
PLL_VSS-VSSA_L6
3VDU
C2217
C1U16Y
CTRL12
32
1
C2225
C4.7U10Y0805
Q2039
P-BCP69_SOT223
4
VCC1.2L
A5A8B1B2B4B5B6B8C1C2C3C6C7D3G3
RESERVED_NC-NC_A5
RESERVED_NC-NC_A8
RESERVED_NC-NC_B1
RESERVED_NC-NC_B2
RESERVED_NC-NC_B4
RESERVED_NC-NC_B5
RESERVED_NC-NC_B6
RESERVED_NC-NC_B8
RESERVED_NC-NC_C1
RESERVED_NC-ADV10
RESERVED_NC-NC_A4
RESERVED_NC-NC_C5
RESERVED_NC-NC_C8
RESERVED_NC-NC_D1
RESERVED_NC-NC_D2
RESERVED_NC-NC_D9
RESERVED_NC-NC_E3
RESERVED_NC-NC_F1
RESERVED_NC-NC_F2
RESERVED_NC-NC_F3
RESERVED_NC-NC_L8
RESERVED_NC-NC_M7
L7A4C5C8D1D2D9E3F1F2F3L8M7M8N7
C2200 X_C0.1U50Y
C2248 C0.1U50Y
C2253 X_C0.1U50Y
C2205 C1U16Y
C2221 C1U16Y
C2244 C1U16Y
RESERVED_NC-NC_C2
RESERVED_NC-NC_C3
RESERVED_NC-NC_C6
RESERVED_NC-NC_C7
RESERVED_NC-NC_M8
RESERVED_NC-NC_N7
RESERVED_NC-NC_N11
RESERVED_NC-NC_P4
N11P4P5P6A1
RESERVED_NC-NC_D3
RESERVED_NC-NC_G3
RESERVED_NC-NC_P5
RESERVED_NC-NC_P6
CORE_VDD-VCCR_G5
CORE_VDD-VCC3.3_G6
CORE_VDD-VCCR_H5
CORE_VDD-VCC3.3_H6
CORE_VDD-VCC3.3_H7
CORE_VDD-VCC3.3_H8
CORE_VDD-VCC3.3_J6
CORE_VDD-VCC3.3_J7
CORE_VDD-VCC3.3_J8
CORE_VDD-VCC3.3_J9
CORE_VDD-VCC3.3_J10
CORE_VDD-VCC3.3_J11
CORE_VDD-VCC3.3_K5
CORE_VDD-VCC3.3_K6
CORE_VDD-VCC3.3_K7
CORE_VDD-VCC3.3_K8
CORE_VDD-VCC3.3_K9
CORE_VDD-VCC3.3_K10
CORE_VDD-VCC3.3_K11
CORE_VDD-VCC3.3_L4
CORE_VDD-VCC3.3_L5
CORE_VDD-VCC3.3_L9
CORE_VDD-VCC3.3_L10
ANALOG_1.2V-VCCT_E11
ANALOG_1.2V-VCC3.3_H11
ANALOG_1.2V-VCCT_E12
ANALOG_1.2V-VCC3.3_G13
IEEE_TEST--ISOL_TCK
RESERVED_NC-ISOL_EXEC
RESERVED_3.3V-VCC3.3
RESERVED_VSS-VSS_D6
RESERVED_VSS-VSS_E10
RESERVED_VSS-VSS_F5
RESERVED_VSS-VSS_D4
RESERVED_VSS-VSS_E4
NC-NC_A1
NC-NC_A14
NC-NC_P1
NC-NC_P14
A14P1P14
C2226 C1U16Y
C2267 X_C1U10Y
C2245 X_C1U10Y
C2227 C1U16Y
C2247 X_C1U10Y
CORE_VDD-VCCR_J5
VDDPST-VCC3.3_A3
VDDPST-VCC3.3_A7
VDDPST-VCCT
VDDPST-VCC3.3_E1
VDDPST-VCC3.3_K3
VDDPST-VCCP_K13
VDDPST-VCCA_N6
VDDPST-VCCA_N8
VDDPST-VCC3.3_P2
VDDPST-VCCP_P12
VDDR1P8-NC_D11
VDDR1P8-NC_G12
CLKR1.8V-ISOL_TI
IEEE_TEST+-RBIAS10
CTRL18-RBIAS100
CTRL12-NC
TEST-TESTEN
G5
G6
H5
H6
H7
H8
J5
J6
J7
J8
J9
J10
J11
K5
K6
K7
K8
K9
K10
K11
L4
L5
L9
L10
E11
H11
E12
G13
A3
A7
A11
E1
K3
K13
N6
N8
P2
P12
D11
G12
D12
B14
D14
B13
P11
D10
A13
K4
D6
E10
F5
D4
E4
VCC1.8LVCC1.2L3VDU
C2208 X_C1U10Y
C2192 C1U16Y
C2212 C1U16YC2246 X_C1U10Y
C2209 X_C1U10Y
C2210 X_C1U10Y
C2201 X_C1U10Y
VCC1.2L
3VDU
VCC1.8L
C2199
C0.01U50X
R2214 549R1%
CTRL18
CTRL12
3VDU
Title
MS-6758
Size Document Number Rev
RealTek RTL8100C/8110S LAN Controller 20D
5
4
3
2
Date: Sheet
1
24 29Friday, February 13, 2004
of
Page 25

5
4
3
2
1
U20
CHIP_RST#6,24,27,28
D D
CPU_THERMDA7
LPC_AGND
C C
TURBO6
VBAT
B B
SIO_PCLK336
LPC_LDRQ#017
LPC_FRAME#6,17,28
LPC_LAD06,17,28
LPC_LAD16,17,28
LPC_LAD26,17
LPC_LAD36,17
R363 30KR1%
C338
C3300P50X
R340 2MR
LPC_PME#17
PWRBTIN#17
PWRBTIN_IO28
CHIP_RST#
SIO_PCLK33
SERIRQ#
SERIRQ#17
LPC_LDRQ#0
LPC_FRAME#
LPC_LAD0
LPC_LAD1
LPC_LAD2
LPC_LAD3
DLED#4
DLED#2
DLED1 FDD_RDDATA#
DLED4
DLED#3
DLED#1
DLED2
DLED3
LPC_VTIN1
CPU_THERMDA
PCB3
LPC_-12VIN
VCC3
LPC_+12VIN
VCORE
VCORE
FANPWM1
FANIO1
FANPWM2
FANIO2
CASEOPEN#
R351 4.7KR
3VDU
LPC_PME#
PCB1
SMBDATA
SMBDATA6,13,14,17,21,27
SMBCLK
SMBCLK6,13,14,17,21,27
PWRBTIN#
PWRBTIN_IO
PCB2
PSON#
PSON#28
SLP_S3#
SLP_S3#17,27
SIO_48M
SIO_48M6
5VSB
VBAT_SIO
VCC3
VCC
C321
C0.1U50Y
Closed to Pin_61
RTSA#
R309 4.7KR
SOUTA
R308 4.7KR
SOUTB
L: CFAD=2E
L: PNP Default H: PNP no DefaultDTRA#
R352 4.7KR
H: Enable KBCL: Disable KBC
H: 48MHZ
H: CFAD=4E
ALARM
VCC
Q32
N-MMBT3904_SOT23
SOUTA
SOUTB L: 24MHZ
RTSA#
R301 1KR
A A
LPC_BEEP
R300 4.7KR
W83627THF
30
LRESET#
21
PCI_CLK
23
SERIRQ
22
LDRQ#
29
LFRAME#
27
LAD0
26
LAD1
25
LAD2
24
LAD3
125
GPX2/P15/GP13
123
GPY1/GP15
128
GPSA1/P12/GP10
121
GPSA2/GP17
126
GPX1/P14/GP12
124
GPY2/P16/GP14
127
GPSB1/P13/GP11
122
GPSB2/GP16
120
MSO/IRQIN0/GP20
119
MSI/GP21
101
VREF
102
VTIN3
103
VTIN2
104
VTIN1
93
GPIO26
94
GPIO25
95
GPIO24
96
GPIO23
97
VIN2
98
VIN1
99
VIN0
100
VCORE
106
VID4/GPIO54
107
VID3/GPIO53
108
VID2/GPIO52
109
VID1/GPIO51
110
VID0/GPIO50
116
FANPWM1
113
FANIO1
115
FANPWM2
112
FANIO2
111
OVT#
105
VID5/GPIO55
118
GPIO22
76
CASEOPEN#
19
PME#
89
WDTO/GP33
91
SDA/GP31
92
SCL/GP30
67
PSOUT#/GP47
68
PSIN/GP46
64
SUSLED/GP37
90
PLED/GP32
72
PWRCTL#/GP42
73
SLP_S3#/GP41
18
CLKIN
61
5VSB
74
VBAT
28
VCC3
12
VCC_1
48
VCC_2
77
GPIO36
114
AVCC
C339
C0.1U50Y
Closed to Pin_114
VCC
ALARM 28
LPC BUS
Parallel PortIR Flopy
For W83627HF only, in 83627F are NC
Serial Port
RSMRST#/GP44
CASEOPEN#
C333 C0.1U50Y
C322 C0.1U50Y
C50 C0.1U50Y
DRVDEN0
LPC_SMI#
INDEX#
MOA#
FANIO3
DSA#
FANPWM3
DIR#
STEP#
WRDATA#
WE#
TRACK0#
WP#
RDDATA#
HEAD#
DSKCHG#
SLCT
BUSY
ACK#
SLIN#
INIT#
ERR#
AFD#
STB#
IRRX/GP34
GPIO45
IRTX
GPIO40
627THF only
DCDA#
DSRA#
SINA
RTSA#
SOUTA
CTSA#
DTRA#
RIA#
DCDB#
DSRB#
SINB
RTSB#
SOUTB
CTSB#
DTRB#
RIB#
GA20M
KBRST
KBDATA
KBCLK
MSDATA
MSCLK
BEEP
PWROK/GP43
VSS1
VSS2
GP35
AGND
PD[7..0]
PD0
PD1
PD2
PD3
PD4
PD5
PD6
PD7
PE
1
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
42
41
40
39
38
37
36
35
31
32
33
34
43
44
45
46
47
88
69
87
75
56
50
53
51
54
49
52
57
84
79
82
80
83
78
81
85
59
60
63
62
66
65
58
70
71
20
55
86
117
J8
1
2
D1x2-BK
FDD_DRVDEN0
R2334 4.7KR
FDD_INDX#
FDD_MOA#
FANIO3
FDD_DSA#
FANPWM3
FDD_DIR#
FDD_STEP#
FDD_WRDATA#
FDD_WE#
FDD_TRACK#0
FDD_WP#
FDD_HEAD#
FDD_DSKCHG#
PD0
PD1
PD2
PD3
PD4
PD5LPC_VREF
PD6
PD7
SLCT
PE
RBUSY
RACK#
RSLIN#
RINIT#
RERR#
RAFD#
STB#
R323 4.7KR
DCDA#
DSRA#
SINA
RTSA#
SOUTA
CTSA#
DTRA#
RIA#
R480 X_4.7KR
SOUTB
A20GATE
KB_RST#
KBDATA
KBCLK
MSDATA
MSCLK
LPC_BEEP
LPC_AGND
PD[7..0] 26
VCC
VCC3
C345
C0.1U50Y
3VDU
SLCT 26
PE 26
RBUSY 26
RACK# 26
RSLIN# 26
RINIT# 26
RERR# 26
RAFD# 26
STB# 26
VCC
DCDA# 26
DSRA# 26
SINA 26
RTSA# 26
SOUTA 26
CTSA# 26
DTRA# 26
RIA# 26
A20GATE 17
KB_RST# 17
KBDATA 12
KBCLK 12
MSDATA 12
MSCLK 12
A20GATE
KB_RST#
LPC_LDRQ#0
SERIRQ#
RN90
1
2
3
4
5
6
7
8
8P4R-4.7KR
3
2
PFAN1
1
FAN1X3_white
R307 10KR
R306 10KR
R343 10KR
R339 10KR
VCC
FANPWM2
FANPWM1
FANPWM3
+12V
R6 X_4.7KR
R4 X_4.7KR
R7 X_4.7KR
VCC3
VCC
C12
X_C0.1U50Y
VCC
C5
X_C0.1U50Y
VCC
C6
X_C0.1U50Y
RN88 8P4R-330R
DLED4
DLED3
DLED#2
DLED#1
FDD_DRVDEN0
FDD_INDX#
FDD_MOA#
FDD_DSA#
FDD_DIR#
FDD_STEP#
FDD_WRDATA#
FDD_WE#
FDD_TRACK#0
FDD_WP#
FDD_RDDATA#
FDD_HEAD#
FDD_DSKCHG#
PCB1
PCB2
PCB3
114
-
9
+
10
R24 47KRR22 33KR
114
-
6
+
5
R150 47KRR151 33KR
114
-
2
+
3
R413 47KRR419 33KR
FAN Controller
1
2
3
4
5
6
7
8
FDD1
12
3
78
910
1112
1314
1516
1718
19
20
2122
2324
2526
2728
2930
3132
3334
CONN-FDD(4)(5)(6)V
R315 4.7KR
R316 X_4.7KR
R317 4.7KR
R325 X_4.7KR
R322 4.7KR
R321 X_4.7KR
8
U2C
LM324M_SOIC14
+12V
7
U2B
LM324M_SOIC14
+12V
1
U2A
LM324M_SOIC14
+12V
VCC
DLED#4
DLED#3
DLED2
LPC_AGND7
3VDU
+12V
+
12
EC18
C10U16EL
+12V
+
12
EC25
C10U16EL
+12V
+
12
EC42
C10U16EL
RN89 8P4R-330R
1
3
5
7
R362 28KR1%
+12V
R358 232KR1%
-12V
LPC_AGND
LPC_VREF
SYSTEM THERMAL
必須放在一起
D5
R27
X_1N4148_SOD123
Q13
P-IRFR9024N_TO252
4.7KR
3
2
1
R25 27KR
CFAN1
FAN1X3_white
必須放在一起
D7
R132
X_1N4148_SOD123
Q25
P-IRFR9024N_TO252
4.7KR
3
2
1
R133 27KR
NBFAN1
FAN1X3_white
必須放在一起
D14
R400
X_1N4148_SOD123
VCC
4.7KR
R401 27KR
3
SFAN1
2
FAN1X3_white
1
DLED4
DLED3
DLED1DLED1
R361
10KR1%
CP7 X_COPPER
JLED1 H2X5(9)_black
R359
59KR1%
LPC_VTIN1
LPC_AGND
Q35
P-IRFR9024N_TO252
2
4
6
8
R365 10KR1% RT1 10KRT1%
1 2
3 4
5
7 8
LPC_+12VIN
LPC_-12VIN
FANIO2
R23
10KR
FANIO1
R131
10KR
FANIO3
R396
10KR
DLED#4
DLED#3
DLED#2DLED2
6
DLED#1
10
LPC_VREF
Title
MS-6758
Size Document Number Rev
Winbond W83627THF Super I/O 20D
5
4
3
2
Date: Sheet
1
25 29Friday, February 13, 2004
of
Page 26

5
4
3
2
1
D13
1N4148_SOD123
VCC
D D
C C
PD[7..0]25
RAFD#25
RERR#25
SLCT25
RBUSY25
RACK#25
RSLIN#25
RINIT#25
VCC3 5VDU
C2271
X_C0.1U50Y
PD[7..0]
STB#
STB#25
PD0
RAFD#
PD3 SOUTA
PD4
PD5
PD6
SLCT
PE
PE25
RBUSY
RACK#
PD1
PD2
RSLIN#
RINIT#
PD7
C2272
C2273
X_C0.1U50Y
C0.1U50Y
RN70
8P4R-2.2KR
C2274
X_C0.1U50Y
246
8
135
7
For EMI For EMI
C106
C0.1U50Y
EC20
.CD1000U6.3EL15
R88 2.7KR
R86
5.11KR1%
C104
C0.1U50Y
USB_OC#317
USB_OC#3
Closed to SB
B B
+
RN72
8P4R-2.2KR
246
135
135
246
CN5
8P4C-220P50N
C2275
X_C0.1U50Y
8
7
7
8
C2276
X_C0.1U50Y
CUSBN4
CUSBP4
CUSBN3
CUSBP3
RN74
8P4R-2.2KR
246
8
135
7
135
7
246
8
CN4
8P4C-220P50N
C2277
X_C0.1U50Y
RN71
8P4R-2.2KR
CGND
CN6
8P4C-220P50N
C2278
C1000P50N
JUSB1A
5
6
7
8
UP
1
2
3
DOWN
4
CONN-RCA_USBX2
246
135
7
8
KBVCC
STB#
8
7
135
246
13
14
11
12
R318
2.2KR
C51
C220P50N
CN7
8
6
4
2
8P4C-220P50N
PD0
PD1
PD2
PD3
PD4
PD5
PD6
PD7
RACK#
RBUSY
PE
SLCT
RERR#
7
PD0
5
RAFD#
3
STB#
1
USB_OC#717
5VDU
51
1
2
3
4
5
6
7
8
9
10
11
12
13
LPT1
CONN-LPT
52
NRTSA
NDSRA#
NCTSA#
NRIA#
NDTRA
NSINA
NSOUTA
NDCDA#
NDCDA#
NSOUTA
NRTSA
NRIA#
USB_OC#7
C413
C0.1U50Y
Closed to SB
C124 X_C0.1U25Y
C308 X_C0.1U25Y
C390 C1000P50N
For EMI
14
15
16
17
18
19
20
21
22
23
24
25
48
CN2
1
3
5
7
X_8P4C-180P50N
CN3
7
5
3
1
X_8P4C-180P50N
JCOM1
CONN-COM
1
3 4
5 6
7 8
9 10
R432
5.11KR1%
EC48
.CD1000U6.3EL15
RAFD#
RERR#
RINIT#
RSLIN#
2
4
6
8
8
6
4
2
NSINA
2
NDTRA
NDSRA#
NCTSA#
11
R431 2.7KR
5VDUR
+
FM1
X
X_FM
FM7
X
X_FM
C414
C0.1U50Y
CUSBN7
1N4148_SOD123
RIA#25
CTSA#25
DSRA#25
SINA25
DCDA#25
-12V
1N4148_SOD123
FM14
X
FM5
X
D3
RIA#
CTSA#
DSRA#
SINA
DCDA#
NRTSA
NDTRA
NSOUTA
D4
X_FM
X_FM
EMI1
X__E91-0000036
JUSB2
1 2
3 4
5
7 8
BH2X5(9)USB_yellow
123
123
FM15
X
FM2
X
6
10
X_FM
X_FM
4
4
C15 C0.1U50Y
U3
GD75232_SSOP20
1
V+
19
ROUT1
18
ROUT2
17
ROUT3
14
ROUT4
12
ROUT5
5
DOUT1
6
DOUT2
8
DOUT3
10
V-
C31 C0.1U50Y
FM3
X
FM10
X
X_COPPER
F3
X_F-MINISMDC150
CUSBN8
CUSBP8CUSBP7
USB_OC#7
X_FM
X_FM
CP11
VCC
RIN1
RIN2
RIN3
RIN4
RIN5
DIN1
DIN2
DIN3
GND
C2285
C0.1U50Y
FM16
X
X_FM
FM8
X
X_FM
20
NRIA#
2
NCTSA#
3
NDSRA#
4
NSINA
7
NDCDA#
9
RTSA#RERR#
16
DTRA#
15
13
11
FM13
X
X_FM
FM11
X
X_FM
C2287
C2286
C0.1U50Y
C0.1U50Y
For EMI
5VDU
C314
C0.1U50Y
RTSA# 25
DTRA# 25
SOUTA 25
FM4
X
X_FM
FM12
X
X_FM
C2288
C0.1U50Y
VCC+12V
FM6
X
X_FM
FM9
X
X_FM
VCC
C2289
C0.1U50Y
FB1
USB_OC#1
C122
C0.1U50Y
X_90ohm_0603
1
2
3
4
R97 2.7KR
R96
5.11KR1%
SB_USBN1
SB_USBN117
SB_USBP1
SB_USBP117
SB_USBN2
SB_USBN217
SB_USBP2
SB_USBP217
USB_OC#117
A A
Closed to SB
5
CUSBN1
8
CUSBP1
7
CUSBN2
6
CUSBP2
5
KBVCC
CUSBN2
CUSBP2
CUSBN1
CUSBP1
SB_USBN317
SB_USBP317
SB_USBN417
SB_USBP417
C123
C0.1U50Y
SB_USBN3
SB_USBP3
SB_USBN4
SB_USBP4
CP12
X_COPPER
F2
X_F-MINISMDC200
LAN_USB2A
6
7
2
3
1
5
4
8
XX
4
UP
DOWN
FB2
X_90ohm_0603
1
2
3
4
5VDU
23
24
25
26
27
28
29
30
CUSBN3
8
CUSBP3
7
CUSBN4
6
CUSBP4
5
SB_USBP617
SB_USBN617
SB_USBP517
SB_USBN517
USB_OC#517
SB_USBP6
SB_USBN6
SB_USBP5
SB_USBN5
USB_OC#5
C410
C0.1U50Y
R426 2.7KR
R425
5.11KR1%
Closed to SB
3
FB3
X_90ohm_0603
1
2
3
4
C418
C0.1U50Y
CUSBP6
8
CUSBN6
7
CUSBP5
6
CUSBN5
5
CUSBP5
2
SB_USBN717
SB_USBP717
SB_USBP817
SB_USBN817
JUSB3
1 2
3 4
6
5
7 8
10
BH2X5(9)USB_yellow
SB_USBN7
SB_USBP7
SB_USBP8
SB_USBN8
CUSBN6CUSBN5
CUSBP6
USB_OC#5
Title
Size Document Number Rev
Date: Sheet
FB4
X_90ohm_0603
1
2
3
4
5VDUR
CUSBN7
8
CUSBP7
7
CUSBP8
6
CUSBN8
5
MS-6758
Parallel/Serial and USB Port 20D
1
26 29Friday, February 13, 2004
of
Page 27

5
4
3
2
1
5VSB
R437
R438
330R
330R
D D
PLED1
PLED128
R429 4.7KR
Q39
PLED228
PLED2
Q40
N-MMBT3904_SOT23
N-MMBT3904_SOT23
R430 4.7KR
可放在板邊
VCC3
R230
1KR
C C
SMBCLK6,13,14,17,21,25
SMBDATA6,13,14,17,21,25
FP_RST#6,28
CHIP_PWROK9,16,17
ATXPWROK28
AGP_PRT28
THIS PIN IS OPEN DRAIN OUTPUT
VCC_VID
1.2V/150mA
B B
A A
Place MOSFET near CPU
C108
C10U6.3Y1206
SLOT_RST#
CHIP_RST#
DEV_RST#
0730 Modified
5
Closed to MS7
R229
4.7KR
R2354 100R
R2355 100R
FP_RST#
CHIP_PWROK
ATXPWROK
AGP_PRT
X7R
C268 C0.1U16X
VCC
C266
C0.1U50Y
S
5VSB VCC1.5
D
VCC3
C435 C18P50N
C436 C18P50N
C445 C18P50N
3VDLDEC#
EXTRAM
R224
R221
1KR
1KR
1
SCL
2
SDA
3
FP_RST#
4
CHIP_PWGD
5
CPU_PWGD
6
PWROK_BUF
7
PWROK
8
PSOUT#
9
DDRTYPE
10
SS
11
GND0
12
VCC5
VID_GD
VCC_VID
G
Q22
N-NDS351AN_SOT23
R217 3.3R0805
C257
C1000P50X
48
PLED1/EXTRAM
VID_GD
131415
EC16
.CD1000U6.3EL15
SLP_S3#
VCC
R220
330R
S3#
S5#
PCI_RST#
DEV_RST#
HDD_RST#
SLOT_RST#
PLED0/3VDLDEC#
MS-7
VID_SEN
VID_DRV
5VSB0
RAM_LSEN
RAM_LDRV
RAM_HSEN
RAM_HDRV/DMV
162117182019222324
RAMDRV
C255
C0.1U50Y
+
12
EC59
.CD1000U6.3EL15
R2353 X_4.7KRC2292 X_C0.1U50Y RN96
R442
330R
R487 10R
R218 10R
R212 10R
RSMRST#
C252
C0.1U50Y
3738394041424344454647
VCC3
AGND
RSMRST#
BUF_RST#
CHARPMP
5VSB1
VLR1_DRV
VLR1_SEN
5VUSB_DRV
5V_DRV
VLR2_DRV
VLR2_SEN
GND1
VAGP_DRV
RAM_SBDRV/DMSB
3VSB
3VSB_DRV
VAGP_SEN
MS7-C
5VSB
U11
C2
C1
3VDU
R203
4.7KR1%
R210 10KR1%
SLP_S4#
SLP_S3#
PCI_RST#
IDE_RST#
DEV_RST#
SLOT_RST#
CHIP_RST#
RSMRST# 17,24
VCC3
5VSB
EC31 CD470U10EL11.5
36
35
34
33
32
V1SEN
31
30
29
28
V2SEN
27
26
25
SLP_S4# 17
SLP_S3# 17,25
PCI_RST# 9,16
IDE_RST# 21
DEV_RST# 22,23
SLOT_RST# 12,19,20,21
CHIP_RST# 6,24,25,28
+
C240 C1U16Y
9VSB
C239 C1U16Y
C238 C1U16Y
Wide Trace
AGPSEN
C1000P50XC254
Wide Trace
C43
X_C1000P50X
3VDU
Q11
23
4
N-APM2054N_SOT89
1
G
+
12
+
12
EC27
.CD1000U6.3EL15
4
VCC3
S
D
D
Q10
N-P45N02LD_TO252
S
RAMDRV
G
Q8
N-P45N02LD_TO252
+
12
EC17
.CD1000U6.3EL15
VDIMM
C56
C0.1U50Y
+
12
DDR 2.5V Power
2.5V/7A(DIMM)+5A(NB)
1
2
3
5
7
X_8P4R-0R
5VSB5VDU 5VSB5VDU
4
6
8
ACPI
VDIMM LINEAR OR PWM SELECT
Controller
VDIMM MODE
LINEAR REGULATOR
Q26
X_
CHARGE PUMP
VOLTAGE
OUTPUT
EC47
.CD1000U6.3EL15
5VSB
ATXPWROK
C171
X_C1000P50X
AGP_VREF
X_C1000P50XC425
+
12
R2333 10KR
R156 X_147R1%
R157
X_143R1%
R129
147R1%
R130
143R1%
EC39
X_CD470U16EL11.5
MS-7 Patch Circuit
R2332 4.7KR
Q2041
N-NDS351AN_SOT23
3
G
RN97
1
2
3
4
5
6
7
8
X_8P4R-0R
3VSB MODE SELECT
3VSB MODE
SINGLE MOSFET
PULL HIGHPWM REGULATOR PULL HIGH
VCC3
D
C371
S
+
EC26
X_CD470U10EL11.5
C1U16Y0805
G
For VT6420
VCC3
D
G
For NB VTT Power
C1000P50X
5V_DRV
VCC3
D
N-MMBT3904_SOT23
S
C431
G
4 5
3
2
1
NN-P07D03LV_SO8
CHIP_PWROK
Q2040
S
DS
Q24
N-LP45N02L_TO263AB
Q43
DUAL MOSFET
VATA25
C243
X_C1000P50X
C426
X_C2200P50X
Q23
N-P45N02LD_TO252
P25V
+
12
EC23
X_CD470U10EL11.5
6
7
8
5V_DRV
C417
X__C1200P50X
5VSB
3VDU
3VDLDEC#EXTRAM
PULL LOWPULL LOW
Changed C243 to 1000pF
4 5
3
2
1
NN-P07D03LV_SO8
VCC
+
EC24
.CD1000U6.3EL15
VCC_VID
VID_PWRGD7
VRM_GD5
2
Q42
FRONT
5VSB
VID_GD
SLP_S3#
VCC_VID
VCC1.5
For EMI
VCC3
+
EC49
X_CD1000U6.3EL15
7/28 Modified
5VSB
6
7
8
+
EC29
.CD1000U6.3EL15
VID_PWRGD
VRM_GD
R222 1KR1%
R2348 X_0R
R2349 2.7KR
Q2046
N-MMBT3904_SOT23
R2350 2.7KR
C1U16Y
VCC3VCC3
C448
C0.1U50Y
U11_X
12
_E31-0401031
C82
C0.1U50Y
C8
X_C0.1U50Y
VCC VCC3
12
+
VCC
EC45
X_CD1000U6.3EL15
C7
C0.1U50Y
C139
C0.1U25Y0805
+
12
EC22
.CD1000U6.3EL15
5V DUAL Power
D
G
REAR
S
Q41
X_N-AP40N03H/J_TO252
VCC
Low RDS ON MOSFET
C2268
5VDU
12
+
EC51
.CD1000U6.3EL15
R28 4.7KR
R21 1KR1%
Q12
N-MMBT3904_SOT23
VCC_VID / VID_GOOD
Place MOSFET near CPU
Q2047
N-MMBT3904_SOT23
+
EC46
CD470U10EL11.5
5VDU 5VDU
C429
C0.1U50Y
C430
MS-7 Patch Circuit
Title
MS-6758
Size Document Number Rev
MSI MS-7 ACPI Controller 20D
Date: Sheet
1
C9
C4.7U10Y0805
C0.1U50Y
27 29Friday, February 13, 2004
of
Page 28

5
4
3
2
1
JFP1
R436 330R
D D
C C
B B
ICH_RST#6,17
FP_RST#6,27
VCC
R433 X_0R
C420
X_C0.01U50X
ALARM25
R427 2.2KR
SB_SPKR17
Q38
N-MMBT3904_SOT23
C220P50N
MH7
X_150 Drill / 300 Pad
1
8
2
7
3
6
4 5
9
VRM_PWRGD5,6,17
VCC3
C0.1U50Y
BOOT_SEL8
BOOT_SEL
BOOT_SEL: Low= VREF2=1.45
BOOT_SEL: High= VREF1=1.225
A A
HDD+ PLED1
PLED2
PLED1
ALARM
HDDLED
C422
X_150 Drill / 300 Pad
1
2
3
4 5
VRM_PWRGD
C140
1
3
5
7
RN36
8P4R-0R
C1U16Y0805
R106 X_4.7KR
2
4
6
8
C137
1 2
3 4
R434 100R
6
5
7 8
9
H2X5(10)_black-N31-2051231
JFP2
1 2
3 4
R494 X_0R
6
5
8
H2X4(7)_color-N31-2041101
RN87
1
2
3
4
5
6
7
8
8P4R-150R
C419
C0.1U50Y
D21
IDE_SATA
1N4148_SOD123
IDE_PLED#
D15
1N4148_SOD123
SB_ATALED
D16
1N4148_SOD123
IDE_SLED#
D17
1N4148_SOD123
D20
PATA_IDE
1N4148_SOD123
MH2
8
7
6
9
C154 X_C0.1U50Y
VTT_NBVCORE
PLED2HDDLED
PWRBTIN_IO
VCC
U8
X_W83310DS_SOIC8
7
ENABLE
6
VCNTL
5
BOOT_SEL
VCORE VTT_NB
PLED1 27
PLED2 27
5VSB
IDE_SATA 22
IDE_PLED# 21
SB_ATALED 17
IDE_SLED# 21
PATA_IDE 22
MH3
X_150 Drill / 300 Pad
1
2
3
4 5
9
C150
X_C4.7U16X1206
VINVREF2
GND
VREF1
VOUT
GND
9
C138 X_C0.1U50Y
8
7
6
1
3
5
7
Closed to North Bridge
PWRBTIN_IO 25
R435
C421
10KR
C0.01U50X
X_150 Drill / 300 Pad
1
2
3
4 5
P25V
R111 X_143R1%
VCC3
C136
C4.7U16X1206
18
2
3
4
+
12
EC21
.CD1000U6.3EL15
RN37
2
4
6
8
8P4R-0R
MH6
9
VTT_NB
8
7
6
Vout= 1.45V
R110
X_30.1R1%
R113
X_169R1%
5VSB
PSON#25
AGP_PRT27
MH4
X_150 Drill / 300 Pad
1
2
3
4 5
9
IDE_SDET#21
IDE_PDET#21
FWH_WP#17
LPC_LAD06,17,25
LPC_LAD16,17,25
FWH_AD26
FWH_AD36
LPC_FRAME#6,17,25
FWH_PCLK336
R52 1KR
R71
4.7KR
PSON#
AGP_PRT
5VSB
-12V
5VSB
-5V
MUST BE CLOSED TO POWER CONNECTOR
8
7
6
VCC3
R38 X_0R
R40 4.7KR
C66 C0.1U50Y
C96 C0.1U50Y
C90 C0.1U50Y
FOR EMI ONLY
X_150 Drill / 300 Pad
1
2
3
4 5
C389
C1U16Y0805
FGPI4
R393 4.7KR
FGPI2
IDE_SDET#
IDE_PDET#
FWH_WP#
LPC_LAD0
LPC_LAD1
FWH_AD2
FWH_AD3
LPC_FRAME#
FWH_PCLK33
MH5
9
DS
Q15
G
N-2N7002_SOT23
8
7
6
U22
30
FGPI4
4
FGPI2
5
FGPI1
6
FGPI0
7
WP#
8
TBL#
13
FWH0
14
FWH1
15
FWH2
17
FWH3
23
FWH4
31
CLK
X_150 Drill / 300 Pad
1
2
3
4 5
32
25
1
VPP
VCC
VCC
GND
GND
GNDA VCCA
28 27
26
16
VCC3
-12V
C73
C0.1U50Y
-5V
VCC
VCC +12V
VCC3
VCC
+12V
MH1
8
7
6
9
C375
X_C0.1U50Y
23
RST#FGPI3
24
INIT#
22
RFU
21
RFU
20
RFU
19
RFU
18
RFU
29
IC(VIL)
9
ID3
10
ID2
11
ID1
12
ID0
X_PLCC-32
必須和 放在一起
JPWR1
11
3.3V
3.3V
12
3.3V
-12V
13
GND
GND
14
5V
PSON
15
GND
GND
16
5V
GND
17
GND
GND
18
POK
-5V
19
5VSB
5V
20
12V
5V
PWR-ATX20
C342 C0.1U50Y
C427 C0.1U50Y
C103 C0.1U50Y
EC44 X_CD470U16EL11.5
1 2
+
MH8
X_150 Drill / 300 Pad
1
8
2
7
3
6
4 5
9
VCC3 VCC3
C376
C361
X_C0.1U50Y
X_C0.1U50Y
CHIP_RST#
FWH_INIT#
CHIP_RST# 6,24,25,27
VCC3
CPU_INIT#7,17
Firm Hub
MS-8
1
2
3
4
5
6
7
8
9
10
CPU_INIT#
VCC3
VCC
VCC
5VSB
MH9
X_150 Drill / 300 Pad
1
2
3
4 5
9
VCC3
R414 2.2KR
R416 4.7KR
Q36
N-MMBT3904_SOT23
VCC
8
7
6
FGPI2
FGPI4
R79
4.7KR
C92
C0.1U50Y
ATXPWROK
R415 330R
R376 1KR
C356 C0.1U50Y
R408 1KR
U22_X
BIOS
SST49LF004A
ATXPWROK 27
FWH_INIT#
FWH_INIT#
Q37
N-MMBT3904_SOT23
Title
MS-6758
Size Document Number Rev
ATX Power and BIOS 20D
5
4
3
2
Date: Sheet
1
28 29Friday, February 13, 2004
of
Page 29

5
D D
C C
4
3
2
1
B B
A A
Title
MS-6758
Size Document Number Rev
MS-6758 Rev.20 History 20D
5
4
3
2
Date: Sheet
1
29 29Friday, February 13, 2004
of