Morso Panther, 553 Installation Instructions Manual

1
MORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORSMORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORS
MORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORSMORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORS
MORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORS
E-Mail: stoves@morsoe.com · WE-Mail: stoves@morsoe.com · W
E-Mail: stoves@morsoe.com · WE-Mail: stoves@morsoe.com · W
E-Mail: stoves@morsoe.com · W
ebsite: wwwebsite: www
ebsite: wwwebsite: www
ebsite: www
.morsoe.com
Panther - Gas StovesPanther - Gas Stoves
Panther - Gas StovesPanther - Gas Stoves
Panther - Gas Stoves
Model No. 553
INSTINST
INSTINST
INST
ALLAALLA
ALLAALLA
ALLA
TION INSTRUCTIONSTION INSTRUCTIONS
TION INSTRUCTIONSTION INSTRUCTIONS
TION INSTRUCTIONS
This appliance meets the requirements of the European Gas Directive
BeforBefor
BeforBefor
Befor
e installing ensure installing ensur
e installing ensure installing ensur
e installing ensur
e that the local distribution conditionse that the local distribution conditions
e that the local distribution conditionse that the local distribution conditions
e that the local distribution conditions
(identification of the type of gas and pr(identification of the type of gas and pr
(identification of the type of gas and pr(identification of the type of gas and pr
(identification of the type of gas and pr
essuressur
essuressur
essur
e)e)
e)e)
e)
and the adjustment of the appliance arand the adjustment of the appliance ar
and the adjustment of the appliance arand the adjustment of the appliance ar
and the adjustment of the appliance ar
e compatiblee compatible
e compatiblee compatible
e compatible
This is not a Do It Yourself product
This appliance must be installed by a competent person
These instructions must be left with the userThese instructions must be left with the user
These instructions must be left with the userThese instructions must be left with the user
These instructions must be left with the user
Distributed by: Morsø UK, VDistributed by: Morsø UK, V
Distributed by: Morsø UK, VDistributed by: Morsø UK, V
Distributed by: Morsø UK, V
alley Drive, Swift Valley Drive, Swift V
alley Drive, Swift Valley Drive, Swift V
alley Drive, Swift V
alleyalley
alleyalley
alley
, Rugby, Rugby
, Rugby, Rugby
, Rugby
,,
,,
,
CV21 1TW WCV21 1TW W
CV21 1TW WCV21 1TW W
CV21 1TW W
arks, England - wwwarks, England - www
arks, England - wwwarks, England - www
arks, England - www
.morsoe.com.morsoe.com
.morsoe.com.morsoe.com
.morsoe.com
By appointment to the Royal Danish Court
2
As supplied, this stove is for use with natural gas (G20) When converted using conversion kit no. 555311 this appliance is for use with propane gas (G31) This appliance is for use in the United Kingdom (GB) and the Republic of Ireland (IE) only.
LIST OF COMPONENTSLIST OF COMPONENTS
LIST OF COMPONENTSLIST OF COMPONENTS
LIST OF COMPONENTS
Cast iron stove containing gas burner unit & interior flueway 1 Door handle with fixing screw 1 Ceramic rear base piece 1 Pair of ceramic front base pieces 1 Set of 3 top coals 1 Pair of ceramic firebox side walls 1 8mm nut & olive 1 Key for window 1 Set of Installation and user’ s instructions 1 Flue sealing rope
APPLIANCE DAAPPLIANCE DA
APPLIANCE DAAPPLIANCE DA
APPLIANCE DA
TT
TT
T
AA
AA
A
This product uses fuel effect pieces, firebox side walls and gaskets containing Refractory Ceramic Fibres (RCF), which are man-made vitr eous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract. Consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. T o ensure that the release of fibr es from these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the stove before and after working on the stove. When replacing these articles we recommend that the replaced items ar e not br oken up, but ar e sealed within a heavy duty polythene bag, clearly labelled as RCF waste. This is not classified as “hazardous waste” and may be disposed of at a tipping site licensed for the disposal of industrial waste. Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking. This appliance does not contain any component manufactured from asbestos or asbestos related products.
3
GasGas
GasGas
Gas
Natural (G20) Natural (G20)
Natural (G20) Natural (G20)
Natural (G20)
Propane (G31)*Propane (G31)*
Propane (G31)*Propane (G31)*
Propane (G31)* Inlet Pressure 20mbar 37mbar Input Max. (Gross) 6.8kW 6.8kW
Min. (Gross) 3.1kW 3.0kW
Output Max. (Gross) 4.9kW 4.9kW
Min. (Gross) 2.2kW 2.1kW Burner Test Pressure (Cold) 18.7+0.75mbar 36.5+0.75mbar Gas Connection 8mm pipe 8mm pipe Burner Injector Cat.82 Size 420 Cat. 92 Size 200 Gas rate 0.639m3/h 0.253m3/h Efficiency class 2 2
GENERAL INSTGENERAL INST
GENERAL INSTGENERAL INST
GENERAL INST
ALLAALLA
ALLAALLA
ALLA
TION REQUIREMENTSTION REQUIREMENTS
TION REQUIREMENTSTION REQUIREMENTS
TION REQUIREMENTS
The installation must be in accordance with these instructions. For the user’s protection, in the United Kingdom it is the law that all gas appliances are installed by competent persons in accordance with the curr ent edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. The Council for the Registration of Gas Installers (CORGI) requires its members to work to recognised standards. In the United Kingdom the installation must also be in accordance with: a) All the relevant parts of local regulations. b) The current edition of the Building Regulations issued by the Department
of the Environment and the Welsh Office or the Building Standards
(Scotland) Regulations issued by the Scottish Development Department. c) All relevant codes of practice. d) The relevant parts of the current editions of the following British
Standards:-
BS 1251
BS 5440 Part 1
BS 5440 Part 2
BS 5871 Part 1
BS 6891
BS 8303 In the Republic of Ireland the installation must also conform to the relevant parts of: a) The current edition of IS 813 b) All relevant national and local rules in force.
4
The hearth The hearth
The hearth The hearth
The hearth must be made from a non-combustible material and be at least 600mm wide x 500mm deep x 12mm thick
Clearances Clearances
Clearances Clearances
Clearances from combustible and non-combustible materials must be at least those shown in figure 1
The flueThe flue
The flueThe flue
The flue may be: (a) A conventional open flue.
(b ) A metallic gas flue pipe a diameter of 125 mm. The connection collar is for 150 mm dia. flue pipe. The
flue installation dimensions are shown in figure 1.
No restrictor plate or flue damper is permitted. Where a variable damper is fitted it must be removed or be permanently fixed in the open position.
The flue must be swept before the appliance is installed.
VV
VV
V
entilation:entilation:
entilation:entilation:
entilation: I n the United Kingdom (GB) no special ventilation bricks or vents are requir ed in the room for this appliance. In the Republic of Ireland (I.E.), permanent ventilation must comply with the regulations currently in force.
Location:Location:
Location:Location:
Location: This appliance must not be installed in a private garage or any room, which contains a bath, or shower or where steam is regularly present.
FigurFigur
FigurFigur
Figur
e 1e 1
e 1e 1
e 1
Loading...
+ 8 hidden pages