Morphy richards PERFORMAIR CYCLONIC VACUUM CLEANER user Manual

PerformAir Cyclonic vacuum cleaner
Please read and keep these instructions
Aspirador PerformAir Cyclonic
Leia e guarde estas instruções
g
p
www.morphyrichards.com
71060MP
g
IMPORTANT SAFETY INSTRUCTIONS
he use of any electrical appliance
T requires the following common sense safety rules.
rimarily there is danger of injury or
P death and secondly the danger of
amage to the appliance.
d
Please read before using the appliance.
Location
Do not use or keep this product outside in the rain.
Do not store the appliance near hot surfaces eg ovens or heating appliances.
Mains lead
Do not allow the mains lead to become strained or run this appliance over it.
If the electrical cable becomes damaged the cable assembly must be replaced. Do not attempt this task yourself, contact the helpline number that is found at the bottom of the page.
Personal safety
The plug must be removed from the wall socket before cleaning or maintaining the appliance.
Never modify the cleaner in any way.
Never use in the presence of explosive liquids or vapours.
Never pick up inflammable or poisonous liquids such as petrol, copier toner or other volatile substances. Never pick up acids, asbestos or asbestos dust.
Repairs to electrical appliances ar
• only to be undertaken by trained personnel. Unprofessional repairs can be dangerous for users.
e
Use only genuine Morphy Richards spare parts and accessories.
The appliance must never be left
unning when unsupervised.
r
This vacuum cleaner is intended for
omestic use only. Misuse or use for
d commercial or any other purpose will render the guarantee invalid.
Product safety
Never use the appliance without the filters being installed.
Never use the appliance to vacuum hot ashes, broken glass, sharp objects or liquids.
Children
Children do not understand the dangers associated with operating electrical appliances. Never allow children to use this appliance.
ELECTRICAL REQUIREMENTS
Check that the voltage on the rating plate of your appliance corresponds with your house electricity supply which must be A.C. (Alternating current).
If the socket outlets in your home are not suitable for the plug supplied with this appliance the plug should be removed and the appropriate one fitted.
If you cut off the plug and let go of the cable it will rewind into the machine therefore you must pull out a length of cable and secure it before cutting the plug off and re­fitting a new one.
WARNING: The plug removed from the mains lead, if severed, must be destroyed as a plug with a bared flexible cord is hazardous if engaged into a live socket outlet.
Where used, should the fuse in the 13 amp plug r amp BS1362 fuse must be fitted.
e changing a 13
equir
Í
È
Î
Â
FEATURES
Hose inlet ¤ Dust canisterDust canister release buttonCarrying handleOn/off power switchVariable power switchParking slot
· Tool storage drawerPlug recessCable rewind switchExhaust filter grille  Exhaust filter Ê Dust canister lid Á Pleated, washable dust canister
filter
Ë Mesh filter cover È Standard hose Í Hose handle with airflow
regulator
·
¤
Ù
ı
Î Telescopic tube (length
adjustable)
Ï Combination floor nozzle Ì Hard floor nozzle
(certain models only)
Ó Large turbo nozzle
(certain models only)
Ô Small turbo nozzle
(certain models only)
Upholstery nozzle Ò Clip on brush (attached to  ) Ú Crevice tool
,Ò,Ú ar
Note: tool storage drawer
Û Stretch stair hose Ù Filter cleaning brush ı Dust canister lid release
Ê
Á
Ë
¤
e stor
·.
ed in the
Ì
Ó
Ô
g
Ï
Ú
Ò
Û
.morphyrichar
2
www
ds.com
.morphyrichar
www
ds.com
33
A
B
Ú
Ò
Operating the appliance
Quick start
ssemble the combination floor
1 A
ozzle
n as shown. (Shown on page 3)
2 P
length and plug into the mains supply.
3 S
switch
telescopic tube and hose
Ï,
ull out the mains cable to it’s full
witch on by pressing the on/off
.
TOOLS AND ACCESSORIES
1 Fit the hose to the cleaner by
inserting the hose end into the hose
. When removing, squeeze
inlet the clips either side and pull.
2 Attach the telescopic tube. Extend
to the required length by pushing up the slider release and pulling out the tube
A.
The hose handle features an airflow regulator which allows suction to be reduced as required.
3 Attach your choice of floor nozzle to
the telescopic tube
Î.
Combination floor nozzle
The combination floor nozzle can be adjusted to suit different floor surfaces. Retract the brushes for use on carpet. The brushes should be down for use on hardfloors or damage may occur.
Hand tools
The crevice tool Ú (for awkward places, behind radiators etc) and the upholstery nozzle
Ò (for curtains and
brush upholstery) are stored in the tool drawer
·. The crevice tool is used for hard surfaces, pelmet, delicate objects etc
with clip on
B.
Using the large turbo nozzle
A t
This nozzle is ideal for carpet and especially effective at removing pet h
(certain models only)
ttach the large turbo nozzle to the
elescopic tubes.
air.
Using the small turbo
(
nozzle
A handle and stairs.
WARNING: The turbo nozzle should not be used with the extension tubes. Attach to the hose handle only.
certain models only)
ttach the turbo nozzle to the hose
Í only for use on upholstery
Cleaning the turbo nozzles
The turbo nozzles should be regularly cleaned and any hairs or fibres wrapped around the brush bar removed to maintain optimum performance. To aid cleaning, the small turbo nozzle can be opened up by pushing the button on the nozzle forwards. A cover on the bottom of the large turbo nozzle allows access to the turbine fan.
Hardfloor nozzle
(certain models only)
Attach the hardfloor nozzle to the telescopic tubes. This nozzle is ideal for use on wood, laminate, tile and vinyl flooring.
Stretch stair hose
An additional stretch hose is also provided for use on stairs. Fit the hose to the cleaner by inserting the hose end into the hose inlet. When removing squeeze the clips either side and pull.
WARNING: For safety, always leave the cleaner at the bottom of the stairs and clean upwar
ARNING: W
W recommend using the stair hose for general floor cleaning.
e do not
ds.
Quick guide to accessories:
ombination Large turbo Small turbo Hard floor Crevice tool Upholstery
C
loor nozzle nozzle nozzle nozzle nozzle
f
arpet
C
ugs
R
Wood/ laminate With brushes
Tile
Vinyl
Upholstery
Stairs
Small spaces
33
ith brushes
W
etracted
r
33
With brushes retracted
3 3
down
33
With brushes down
3
CONTROLS
Power
1 Assemble the nozzle, telescopic
tube and hose as shown. (Shown on page 3)
2 Pull out the mains cable to it’s full
length and plug into the mains supply.
3 Switch on by pressing the on/off
power switch
.
Variable power
A Variable power switch fl varies the suction power as required. For example, maximum suction can be used for cleaning carpets, har floors etc. and reduced suction for cleaning upholstery and curtains.
Suction can also be controlled using the airflow regulator on the hose handle. Closed for maximum suction, open for reduced suction.
d
with clip on-brush
33 3 3
3 3
3
Automatic cable rewind
After use, unplug and press the cable rewind switch to retract the cable.
WARNING: When using the cable rewind, always hold the plug as the cable will rewind quickly.
DUST CANISTER
Emptying
To obtain the best results from your cleaner empty the dust canister regularly, otherwise the airflow and cleaning power will be reduced.
1 Everytime the dust canister is
emptied, turn the yellow dial (a minimum of 5 r pressing the dust canister release button (this will agitate the fine dust between the filter pleats and restore the air flow)
evolutions) prior to
g
.morphyrichar
4
www
ds.com
.morphyrichar
www
ds.com
55
Loading...