Monarch SLS-115, SLS-230 Instruction Manual

SLS-115/230
Smart Laser Sensor
MONARCH INSTRUMENT
Instruction Manual
15 Columbia Drive Amherst, NH 03031-2334 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com Website: www.monarchinstrument.com
Printed in the U.S.A.
Copyrighted by Monarch Instrument 2004, all rights reserved
1071-4859-111
CE DECLARATION OF CONFORMITY
As Manufacturer:
Monarch Instrument
Division of Monarch International Inc.
15 Columbia Drive, Amherst NH 03031 USA
declares under Monarch’s sole responsibility that the product:
to which this declaration relates is in conformity with the following directives and
standards when installed and operated in accordance with the user manual:
References: Retlif Testing Laboratories, (Report No. R-4283)
Technical Construction File SLS-0604 of June 2004
SLS - Smart Laser Sensor
15th June 2004
Manufacturer (Amherst,NH) Alan Woolfson, VP Engineering (Authorized Signature)
Directives: EMC 89/336/EEC
Low Voltage 73/23/EEC
Standards: EMC: EN61326:1997
Electrical Safety: IEC61010-1:2001 Laser Safety: IEC60825-1:2001
SAFEGUARDS AND PRECAUTIONS
WARNING - This product emits a visible beam of laser light. Avoid exposure to the laser radiation. The use of optical viewing aids (binoculars, for example) may increase the ocular hazard.
CAUTION - The laser beam should not be intentionally aimed at people or animals.
CAUTION - Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
WARNING - Use only the “PR Universal” charger supplied with the product.
Read and follow all instructions in this manual carefully, and retain this manual for future reference.
Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated.
This instrument is not user serviceable. For technical assistance, contact the sales organization from which you purchased the product.
12
Examples:
1234.56<cr>
123456.<cr>
_ _ _ _0.0<cr> ( _ = space character)
10.0 CHARGING
Slide the Power switch (8) to the Off/Charge position and plug in the charger. The Power LED (4) will blink red while the unit is fast charging. The Power LED will blink amber when slow (trickle) charging. It will be solid amber when the batteries are fully charged.
Note: If the charger is plugged in when the Power switch is the on
position, the batteries will be trickle charged during operation.
CAUTION: Use only the supplied PR-Universal charger with the
sensor.
11.0 ACCESSORIES
T- 5 Reflective Tape, 5 foot [1.5 m] roll, ½ inch [13 mm] wide
T-5WP Waterproof Reflective Tape (honeycomb pattern), 5
foot [1.5 m] roll, 1 inch [25 mm] wide
SLS-CA-BNC Cable assembly with BNC connector (SO)
SLS-CA-W Cable assembly with tinned leads
SLS-CA-P Cable assembly with 1/8 inch [3.5 mm] mono plug (SO)
SLS-CA-RS232 Cable assembly with DB9 connector for RS232
SLS Battery Pack Replacement rechargeable Ni-Cd batteries
PR Universal Recharger/Power Supply with assorted adapter plugs
TABLE OF CONTENTS
TABLE OF CONTENTS
Symbols on the unit and in this manual:
Warning Direct current Laser Beam
Caution Alternating current Read Manual
1.0 SMART LASER SENSOR SPECIFICATIONS ............. 1
2.0 OVERVIEW ................................................................. 4
3.0 INDICATORS AND SWITCHES .................................. 5
4.0 QUICK START GUIDE ................................................ 6
5.0 CONNECTION DETAIL ................................................7
6.0 OPERATION ............................................................... 9
6.1 Auto Mode ...................................................................... 9
6.2 Manual Mode ............................................................... 10
7.0 ADVANCED FEATURE (TARGET POLARITY)........... 10
8.0 AIMING THE LASER ................................................. 11
9.0 RS232 ....................................................................... 11
10.0 CHARGING ............................................................... 12
11.0 OPTIONS / ACCESSORIES ......................................12
11
To change the setting, move the Polarity switch (5) to the left (positive pulse) for a white target or to the right (negative pulse) for a black target. Turn the Sensitivity Adjust knob (7) to Max. Press and hold the Learn/ Gain button (6) until the Auto/Gain LED (3) blinks.
8.0 AIMING THE LASER
The proper operation of the Laser Sensor is dependent upon the alignment to and reflectivity of the target. In order to aim the beam it is necessary to stand behind the sensor and view the target along the plane of the beam. Do not stare directly into the laser beam or the reflected light. For targets greater than 5 feet and up to 65 feet from the sensor, mount the laser on a tripod using the ¼ - 20 bushing on the bottom of the unit and attach T-5 reflective tape to the target.
To aid in locating the laser dot over a large distance, hold a piece of white cardboard or equivalent in front of the laser. Progressively move the white surface closer to the desired target. Then adjust the aim of the laser as necessary.
In areas of high ambient light (outdoors), performance can be enhanced at long distances by slipping a piece of black tube with a minimum inner diameter of 0.6 inches, over the nose piece to act as an extension nose piece. This tube should not deflect the beam in any way.
9.0 RS232
Baud rate = 9600, 8 bits, 1 stop bit, no parity.
When the unit is turned on, it will send out: “SLS<lf><cr>Vx.x<lf><cr>
0.0<cr>”. Where <lf> is the linefeed character, <cr> is a carriage return character, and x.x is the firmware version number.
The unit will send out the current RPM as a right justified 7-digit ASCII number that will always include a decimal point followed by carriage return. The update rate is a function of the speed of the target and will not exceed twice per second.